INTELLIGENT FIRE ALARM CONTROL PANEL

FX-400

Description
The FX-400 Addressable Fire Alarm Control Panel is an intelligent addressable multi-zoned panel, ideal for small to medium jobs.
The FX-400 is shipped pre-assembled with main board, power supply, transformer, main display, black backbox, and black or red door enclosure.
Compatible with MGC Devices (MIX-4000 Series), the FX-400 comes with one addressable (SLC) loop with a maximum of 240 MGC devices in total.
The FX-400 is equipped with a built-in dialer. The dialer provides a means to communicate panel status to the remote central monitoring station using two dedicated phone lines.

Features
Mircom's FX-400 Addressable Fire Alarm Control Panel provides the following: · Main Board, Power Supply and Backbox.
· One addressable (SLC) loop with a maximum of 240 MGC devices (MIX-4000 series) in total.
· Mulit-zone fire alarm control panel.
· Compatible with MGC devices (MIX-4000).
· Compatible with conventional detectors using MGC MIX- 4042 Conventional Zone module, refer to document LT-1023 for compatible detectors.
· Main Display with 4 x 20 LCD display.
· Class A, Class X or Class B analog loop(s).
· Four Power Limited Class B, Class A NAC circuits (max 1.5 Amps each - 5.0 Amps total).
· NAC circuits may be configured as silenceable signal, nonsilenceable signal, silenceable strobes, non-silenceable strobes, or auxiliary power output. The audible signal may be Steady, Temporal Code, California Code, or March Time.
· Supports sync strobe protocols from major manufacturers.
· Software configuration.
· Configurable Signal Silence Inhibit, Auto Signal Silence, and One-Man WalkTest.
· Two-stage, Alarm verification and positive alarm sequence operations.
· Subsequent Alarm, Supervisory, Monitor and Trouble operation.
· Dedicated common alarm, supervisory, trouble, and auxiliary alarm relays.
· Relay Contacts for Common Alarm, Common Supervisory and Common Trouble all non-disconnectable and Auxiliary Alarm Relay (disconnectable).
· Additional outputs include connections for a RTI remote trouble indicator, PR-300 Reverse Polarity Module, an RS- 485 bus for connection of up to seven RAX-LCD-LITEs, RAM-3318-LCDs, SRM-312s and RA-1000 Series annunciators.
· Auxiliary power is available in the form of 24V FWR unfiltered and unsupervised, 24VDC filtered and regulated, and resettable auxiliary power supply.
· Built-in Dialer Module.

NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY.
firealarmresources.com

CATALOG NUMBER
5981

System Components

RAM-3318-LCD Remote Annunciator The RAM-3318-LCD Remote Annunciator is used as a component of an FX-400 Fire Alarm System. It provides an exact mimic of the FX-400 display at a remote location. The display is four lines, 20 characters back-lit alphanumeric LCD. It displays information regarding the panel, its circuits, and devices. An on-screen cursor is controlled by the cursor buttons for menu selection and control. the RAM-3318-LCD occupies one display positon in the BB-1000 enclosure.

RAX-LCD-LITE Remote LCD Annunciator The FX-400 also supports the RAX-LCD-LITE Remote LCD Annunciator. It is equipped with a large 4-line x 20-character back-lit alphanumeric LCD display that uses a simple menu system complete with a directional keypad and switches for Enter, Menu, Cancel and Info. The RAX-LCD-LITE occupies one display position in the BB-1000 enclosures.

RAM-1032TZDS-CC Conformal Coated Main Remote LED Annunciator The RAM-1032TZDS-CC Conformal Coated Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. The RAM-1032TZDSCC has indicators for A.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. Each display point can be identified by the slide-in label that slides in beside the LED. The RAM-1032TZDS-CC occupies one display position in the BB-1001WP(R)A or BB-1002WP(R)A enclosures.

RAM-1032TZDS Main Remote LED Annunciator The RAM-1032TZDS Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. The RAM-1032TZDS has indicators for A.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. The RAM-1032TZDS occupies one display position in the BB-1000 enclosure.

RAX-1048TZDS-CC Conformal Coated Programmable LED Annunciator Module The RAX-1048TZDS-CC Conformal Coated Programmable LED Annunciator Module provides 48 programmable bi-colored LEDs. The RAX-1048TZDS-CC connects to the main control unit or main annunciator module (RAM-1032TZDS) when mounted remotely. Each display point can be identified by the slide-in label that slides in besides the LED. The RAX-1048TZDS occupies one display position in the BB-1001WP(R)A or BB-1002WP(R)A Series enclosures.

RAX-1048TZDS Programmable LED Annunciator Module The RAX-1048TZDS Programmable LED Annunciator Module provides 48 programmable bi-colored LEDs. The RAX-1048TZDS connects to the main control unit or main annunciator module (RAM-1032TZDS) when mounted remotely. Each display point can be identified by the slide-in label that slides in beside the LED. The RAX-1048TZDS occupies one display position in the BB-1000 Series enclosures.

NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY.
firealarmresources.com

CAT. 5981 Page 2 of 6

AGD-048 Graphic Annunciator Adder Driver Board The AGD-048 Adder Graphic Driver Module can be used with the MGD-32 Master Graphic Driver modules, or if located remotely it must be connected and mounted with the RAX-LCD Shared Display. The AGD-048 will support an additional 48 supervised outputs. As with the master modules, the AGD-048 will support both LEDs and incandescent lamps.

UIMA4 Interface for Configuring MGC Fire Panels The UIMA4 is an interface for configuring FX-400. The UIMA4's ribbon cable can be disconnected and replaced ­ the replacement part number is RPL-WC-25022 (it comes with 3 replacement cables). The UIMA4 interface has 3 connectors: 9 pin male serial connector, USB B female connector, and 10 pin female connector.

MGD-32 Master Graphic Driver Module For use with FX-400 Fire Alarm Control Panels. The MGD-32 Master Graphic Driver Module provides common control inputs for the switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test and Acknowledge.

PR-300 Polarity Reversal/City Tie Module The PR-300 provides outputs for city box and polarity reversal applications. As a city tie module, the PR300 provides an interface between the control panel indicating circuits and a master box. It provides off-premises signal transmission for systems that must comply with NFPA requirements for Auxiliary Protective Systems. As a polarity reversal module, the PR-300 provides an interface between the control panel and a reverse polarity receiver.

RTI-1 Trouble Remote Indicator Mircom's Remote Trouble Indicator provides remote annunciation of fire alarm troubles. The RTI-1 mounts onto a standard single gang electrical box. The RTI-1 can be used with any of Mircom's fire alarm control panels.

MP-300 End of Line Plates Mircom's MP-300 is a 3.9K End Of Line resistor for use with Mircom conventional panels and detection circuits.

NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY.
firealarmresources.com

CAT. 5981 Page 3 of 6

BB-1001WP(R)A Outdoor Weather Protected Enclosure The BB-1001WP(R)A is a complete enclosure that comes with either a RED or WHITE door, a black back-box, two keys and a durable lock at the top of the door. The door comes hinged to the bottom side of the box for added weather protection. The box is capable of handling one RAM-1032TZDS-CC Main Annunciator Chassis which provides up to 32 points of annunciation. RAM-1032TZDS-CC is ordered separately conform with the UL, ULC installation requirements.
Note: there is no need for thermostat or heater. RAM-1032TZDS-CC must be ordered separately to match UL, ULC installation requirements.

Dimensions

11-5/32" H x 12-15/16" W x 3-1/2" (283mm x 329mm x 89mm)

Rated for Outdoor Enviroment +50ºC to -40ºC (-122ºF to -40ºF)

Wet Location

95% R.H. @60ºC

BB-1002WP(R)A Outdoor Weather Protected Enclosure The BB-1002WP(R)A is a complete enclosure that comes with either a RED or WHITE door, a black back-box, two keys and a durable lock at the top of the door. The door comes hinged to the bottom side of the box for added weather protection. The box is capable of handling one RAM-1032TZDS-CC Main Annunciator Chassis which provides up to 32 points of annunciation and one RAX1048TZDS-CC Adder Annunciator, which provides up to 48 points of annunciation. RAM-1032TZDS-CC and RAX1048TZDS-CC are ordered separately to match the UL, ULC installation requirements.
Note: there is no need for thermostat or heater. RAM-1032TZDS-CC and RAX-1048TZDS-CC must be ordered separately to match UL, ULC installation requirements.

Dimensions

17-15/16" H x 12-15/16" W x 3-1/2" (456mm x 329mm x 89mm)

Rated for Outdoor Enviroment +50ºC to -40ºC (-122ºF to -40ºF)

Wet Location

95% R.H. @60ºC

SRM-312R Smart Relay Module with Red Enclosure The SRM-312R provides twelve configurable relay circuits, rated @ 28 VDC, 1 amp (resistive). Each circuit can be configured as a Normally Open (N.O.) or Normally Closed (N.C.) contact. Each relay is equipped with an LED that is lit when the relay is energized. The relays can be configured as relay per zone (1 to 1), Common on Alarm, Common on Supervisory or programmable for a logical or adjacent zone configuration. An adjacent zone configuration will turn on an adjacent zone when the configured zone is active. A chaining configuration allows for multiple relays to turn on. The SRM-312R is DIP switch configurable and connects to the RS-485 bus. The SRM-312R come complete with a red enclosure and a CAT-30 lock and key.

BB-1001 / 2 / 3 / 8 / 12 Remote Annunciator Enclosures The BB-1000 Series comes complete with a backbox, door and hinge. The enclosures doors come with Lexan windows, two keys and a durable lock. The enclosures can handle the RAM-1032TZDS, RAM-3318-LCD, RAXN-LCD-LITE, Main Annunciator Chassis.

BB-1001D / DR / DS / DB BB-1002D / DR / DS / DB BB-1003D / DR / DS / DB BB-1008D / DR / DB BB-1012D / DR / DB

9" H x 12.75" W x 1.85" D 18" H x 12.75" W x 1.85" D 26.4" H x 12.75" W x 1.85" D 33" x 22.5" W x 1.85" D 45" H x 22.5" W x 1.85" D

NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY.

CAT. 5981 Page 4 of 6

firealarmresources.com

Ordering Information

Model

Description

Panel

FX-400B

Intelligent Fire Alarm Control Panel - Black door

FX-400R

Intelligent Fire Alarm Control Panel - Red door

Displays

RAM-3318-LCD

Remote Annunciator with 4-Line LCD Display

RAX-LCD-LITE

Remote Annunciator with 4-Line LCD Display

RAM-1032TZDS

32 Point Remote Main Annunciator with 32 Trouble and Alarm LEDs

RAM-1032TZDS-CC

Conformal Coated 32 Point Remote Main Annunciator with 32 Trouble and Alarm LEDs

RAX-1048TZDS

Adder Annunciator Chassis c/w 48 Bi-Colored LEDs

RAX-1048TZDS-CC

Conformal Coated Adder Annunciator Chassis c/w 48 Bi-Colored LEDs.

MGD-32

Master Graphic Driver Board

AGD-048

Adder Graphic Driver Board

SRM-312R

Smart Relay Module with Red Enclosure. Supports up to 12 relays

Optional Adder Modules

PR-300

Polarity reversal and City Tie Module

Enclosures

BB-1001D

White Remote Annunciator Enclosure. Houses one module.

BB-1001DR

Red Remote Annunciator Enclosure. Houses one module.

BB-1001DS

Stainless Steel Remote Annunciator Enclosure. Houses one module.

BB-1001DB

Black Remote Annunciator Enclosure. Houses one module

BB-1002D

White Remote Annunciator Enclosure. Houses two modules.

BB-1002DR

Red Remote Annunciator Enclosure. Houses two modules.

BB-1002DS

Stainless Steel Remote Annunciator Enclosure. Houses two modules.

BB-1002DB

Black Remote Annunciator Enclosure. Houses two modules.

BB-1003D

White Remote Annunciator Enclosure. Houses three modules.

BB-1003DR

Red Remote Annunciator Enclosure. Houses three modules.

BB-1003DS

Stainless Steel Annunciator Enclosure. Houses three modules.

BB-1003DB

Black Annunciator Enclosure. Houses three modules.

BB-1008D

White Remote Annunciator Enclosure. Houses eight modules.

BB-1008DR

Red Remote Annunciator Enclosure. Houses eight modules.

BB-1008DB

Black Remote Annunciator Enclosure. Houses eight modules

BB-1012D

White Remote Annunciator Enclosure. Houses twelve modules.

BB-1012DR

Red Remote Annunciator Enclosure. Houses twelve modules.

BB-10012DB

Black Remote Annunciator Enclosure. Houses twelve modules.

BB-1001WPA

White Weather Protected Enclosure. Houses one module.

BB-1001WPRA

Red Weather Protected Enclosure. Houses one module.

BB-1002WPA

White Weather Protected Enclosure. Houses two modules.

BB-1002WPRA

Red Weather Protected Enclosure. Houses two modules.

Accessories

RTI-1

Common Remote Trouble Indicator, Buzzer and LED

MP-300

End of Line Resistor plate. 3K9

BC-160R

External Battery Cabinet - Red

BAT-12V12A

Battery 12AH

BAT-12V18A

Battery 18AH

BAT-12V26A

Battery 26AH (To house BAT-12V26A (26 AH) batteries, an external BC-160R Battery Cabinet is required.)

UIMA4

Interface for Configuring MGC Fire Panels

MGC-CONFIG-KIT4

Fire Panel Configuration KIT with UIMA4

RPL-WC-25022

Replacement Ribbon Cable for UIMA4 (Pack of 3)

NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY.
firealarmresources.com

CAT. 5981 Page 5 of 6

Ordering Information cont'd

Model MGC Devices MIX-4001 MIX-4002 MIX-4010 MIX-4010-ISO MIX-4020 MIX-4020-ISO MIX-4030 MIX-4030-ISO MIX-4040 MIX-4041 MIX-4042 MIX-4045 MIX-4046 MIX-4050 MIX-4070 MIX-4090 MS-401MPU MS-407MPU MS-710MPU

Description
6" Diameter Base 4" Diameter Base Photoelectric Smoke Sensor Photoelectric Smoke Sensor with Built-in Short Circuit Isolator Multi-Sensor Detector Multi-Sensor Detector with Built-in Short Circuit Isolator Tri-Mode Heat Detector Tri-Mode Heat Detector with Built-in Short Circuit Isolator Dual Input Module Mini Dual Input Module Conventional Zone Module Dual Relay Module Supervised Output Module Sync Module Short Circuit Isolator Module MGC Devices Programmer Intelligent Single Stage Manual Station MP Intelligent Single Stage Manual Station MP with Additional N.C. Switch Intelligent Key-Resettable Single Stage Dual Action Manual Station MP

Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113
www.mircom.com

U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113

THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY.
For complete and accurate technical information relating to performance, installation, testing and certification, refer to technical literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Mircom does not represent or warrant correctness or completeness.

firealarmresources.com

CAT. 5981 Rev. 2



References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Macintosh)