FCC PART 15

news

Test Report 5GWLAN band 3

Shenzhen Cudy Technology Co., Ltd. RT02 2APRGRT02 2APRGRT02 rt02

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=6581050
Page 1 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

FCC TEST REPORT For
Shenzhen Cudy Technology Co., Ltd. Wi-Fi Router
Test Model: WR3000 Additional Model No.: Please Refer to Page 6

Prepared for Address

: Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan District,
: Shenzhen, China

Prepared by
Address
Tel Fax Web Mail

: Shenzhen LCS Compliance Testing Laboratory Ltd. 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei,
: Shajing Street, Baoan District, Shenzhen, 518000, China
: (+86)755-82591330 : (+86)755-82591332 : www.LCS-cert.com : webmaster@LCS-cert.com

Date of receipt of test sample Number of tested samples Sample No. Serial number Date of Test Date of Report

: March 17, 2023 : 2 : A031723030-1, A031723030-2 : Prototype : March 17, 2023 ~ April 10, 2023 : April 10, 2023

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 2 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

FCC TEST REPORT FCC CFR 47 PART 15 E (15.407)
Report Reference No. ................. : LCSA031723030EE
Date of Issue ................................. : April 10, 2023
Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei,
Address ......................................... : Shajing Street, Baoan District, Shenzhen, 518000, China Full application of Harmonised standards 
: Testing Location/ Procedure .......... Partial application of Harmonised standards 
Other standard testing method  Applicant's Name.......................... : Shenzhen Cudy Technology Co., Ltd.
Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan Address ......................................... :
District, Shenzhen, China
Test Specification
Standard........................................ : FCC CFR 47 PART 15 E (15.407)
Test Report Form No. ................... : LCSEMC-1.0
TRF Originator ............................... : Shenzhen LCS Compliance Testing Laboratory Ltd.
Master TRF ................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description............................ : Wi-Fi Router Trade Mark .................................... : Cudy Test Model..................................... : WR3000 Ratings .......................................... : Input: 12V 1A
For AC Adapter Input: 100-240V~, 50/60Hz, 0.5A MAX Adapter Output: 12.0V 1.0A, 12.0W Result .......................................... : Positive

Compiled by:

Supervised by:

Approved by:

Li Huan/Administrator

Cary Luo/ Technique principal

Gavin Liang/ Manager

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 3 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Test Report No. :

FCC -- TEST REPORT
LCSA031723030EE

April 10, 2023 Date of issue

EUT......................................... : Wi-Fi Router

Test Model............................... : WR3000

Applicant............................... Address.................................. Telephone............................... Fax..........................................

: Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan
: District, Shenzhen, China
: / : /

Manufacturer........................ Address................................... Telephone............................... Fax..........................................

: Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan
: District, Shenzhen, China
: / : /

Factory................................... Address................................... Telephone............................... Fax..........................................

: Shenzhen Cudy Technology Co., Ltd. Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan
: District, Shenzhen, China
: / : /

Test Result:

Positive

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 4 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Report Version 000

Revision History

Issue Date April 10, 2023

Revision Content Initial Issue

Revised By --

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 5 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

TABLE OF CONTENTS
1.GENERAL INFORMATION ........................................................................................................................ 6 1.1. DESCRIPTION OF DEVICE (EUT) ............................................................................................................. 6 1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS .................................................................................. 8 1.3. EXTERNAL I/O PORT .............................................................................................................................. 8 1.4. DESCRIPTION OF TEST FACILITY ............................................................................................................. 8 1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY .................................................................................. 8 1.6. MEASUREMENT UNCERTAINTY ................................................................................................................ 8 1.7. DESCRIPTION OF TEST MODES ............................................................................................................... 9 1.8. CHANNEL LIST AND FREQUENCY ........................................................................................................... 10
2. TEST METHODOLOGY ........................................................................................................................... 11 2.1. EUT CONFIGURATION .......................................................................................................................... 11 2.2. EUT EXERCISE .................................................................................................................................... 11 2.3. GENERAL TEST PROCEDURES .............................................................................................................. 11 2.4. TEST SAMPLE ...................................................................................................................................... 11
3. SYSTEM TEST CONFIGURATION ......................................................................................................... 12 3.1. JUSTIFICATION ..................................................................................................................................... 12 3.2. EUT EXERCISE SOFTWARE .................................................................................................................. 12 3.3. SPECIAL ACCESSORIES ........................................................................................................................ 12 3.4. BLOCK DIAGRAM/SCHEMATICS.............................................................................................................. 12 3.5. EQUIPMENT MODIFICATIONS ................................................................................................................. 12 3.6. TEST SETUP ........................................................................................................................................ 12
4. SUMMARY OF TEST RESULTS ............................................................................................................. 13
5. TEST RESULT ......................................................................................................................................... 14 5.1. 6DB OCCUPIED BANDWIDTH MEASUREMENT ......................................................................................... 14 5.2. 99% OCCUPIED BANDWIDTH MEASUREMENT ........................................................................................ 15 5.3. MAXIMUM CONDUCTED OUTPUT POWER MEASUREMENT ....................................................................... 16 5.4. POWER SPECTRAL DENSITY MEASUREMENT ......................................................................................... 18 5.5. EMISSIONS IN RESTRICTED BANDS........................................................................................................ 20 5.6. FREQUENCY STABILITY......................................................................................................................... 22 5.7. ON TIME AND DUTY CYCLE ................................................................................................................... 23 5.8. RADIATED EMISSIONS MEASUREMENT................................................................................................... 24 5.9. POWER LINE CONDUCTED EMISSIONS ................................................................................................... 37 5.10. ANTENNA REQUIREMENTS .................................................................................................................. 40
6. LIST OF MEASURING EQUIPMENTS .................................................................................................... 41
7. TEST SETUP PHOTOGRAPHS OF EUT ................................................................................................ 42
8. EXTERIOR PHOTOGRAPHS OF THE EUT............................................................................................ 42
9. INTERIOR PHOTOGRAPHS OF THE EUT............................................................................................. 42

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 6 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

1. GENERAL INFORMATION

1.1. Description of Device (EUT)

EUT Test Model Additional Model No. Model Declaration Power Supply
Hardware Version Software Version WIFI(2.4G Band) Frequency Range Channel Number Channel Spacing Modulation Type
Antenna Description WIFI(5.2G Band) Frequency Range Channel Number
Modulation Type
Antenna Description
5.3G WLAN Frequency Range

: Wi-Fi Router : WR3000
WR3000 Plus, WR1500, TR3000, M3000, RE3000, AP3000, AP3000 :
Outdoor PCB board, structure and internal of these model(s) are the same, So no : additional models were tested : Input: 12V 1A For AC Adapter Input: 100-240V~, 50/60Hz, 0.5A MAX Adapter Output: 12.0V 1.0A, 12.0W : V1 : 1.15.3 : : 2412MHz~2462MHz : 11 Channels for 20MHz bandwidth (2412~2462MHz) 7 Channels for 40MHz bandwidth (2422~2452MHz) : 5MHz : IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Antenna0: External Antenna, 3.61dBi(Max.) Antenna1: External Antenna, 2.35dBi(Max.) : : 5150MHz~5250MHz : 4 channels for 20MHz bandwidth(5180MHz~5240MHz) 2 channels for 40MHz bandwidth(5190MHz~5230MHz) 1 channels for 80MHz bandwidth(5210MHz) 1 channels for 160MHz bandwidth(5250MHz) : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Antenna0: External Antenna, 3.68dBi(Max.) Antenna1: External Antenna, 4.43dBi(Max.) Antenna2: External Antenna, 4.26dBi(Max.)
: 5250-5350MHz

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 7 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Channel Number
Modulation Type
Antenna Description 5.5G WLAN Frequency Range Channel Number
Modulation Type
Antenna Description WIFI(5.8G Band) Frequency Range Channel Number Modulation Type
Antenna Description

: 4 Channels for 20MHz bandwidth(5260MHz-5320MHz) 2 channels for 40MHz bandwidth(5270MHz~5310MHz) 1 channels for 80MHz bandwidth(5290MHz) 1 channels for 160MHz bandwidth(5250MHz)
: IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK)
: Ant0: External Antenna, 3.91dBi(Max.) Ant1: External Antenna, 4.5dBi(Max.) Ant2: External Antenna, 4.16dBi(Max.)
: 5470-5725MHz : 11 Channels for 20MHz bandwidth(5500MHz-5700MHz)
5 Channels for 40MHz bandwidth(5510MHz-5670MHz) 2 Channels for 80MHz bandwidth(5530MHz, 5610MHz) 1 channels for 160MHz bandwidth(5570MHz) : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Ant0: External Antenna, 4.29dBi(Max.) Ant1: External Antenna, 4.87dBi(Max.) Ant2: External Antenna, 4.24dBi(Max.) : : 5725MHz~5850MHz : 5 channels for 20MHz bandwidth(5745MHz~5825MHz) 2 channels for 40MHz bandwidth(5755MHz~5795MHz) 1 channels for 80MHz bandwidth(5775MHz) : IEEE 802.11a: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ax: OFDM (1024QAM, 256QAM, 64QAM, 16QAM, QPSK, BPSK) : Ant0: External Antenna, 3.92dBi(Max.) Ant1: External Antenna, 4.57dBi(Max.) Ant2: External Antenna, 4.3dBi(Max.)

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 8 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

1.2. Host System Configuration List and Details

Manufacturer DEE VAN ENTERPRISE
CO., LTD

Description AC ADAPTER

Model DSA-12PF11-1 2 FUS 120100

Serial Number ---

Certificate FCC

1.3. External I/O Port
I/O Port Description LAN Port
DC Input Port

Quantity 4 1

Cable N/A N/A

1.4. Description of Test Facility
NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024. CAB identifier is CN0071. CNAS Registration Number is L4595. Test Firm Registration Number: 254912.
The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR 16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

1.5. Statement of the Measurement Uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 ­ 4 "Specification for radio disturbance and immunity measuring apparatus and methods ­ Part 4: Uncertainty in EMC Measurements" and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

1.6. Measurement Uncertainty

Test Item

Radiation Uncertainty :

Conduction Uncertainty :

Power disturbance :

Output power

:

Power Spectral Density : Occupied Channel : Bandwidth
Conducted RF Spurious : Emission
Emissions in Restricted : Bands
Frequency Stability :

Frequency Range 9KHz~30MHz
30MHz~200MHz 200MHz~1000MHz
1GHz~26.5GHz 26.5GHz~40GHz 150kHz~30MHz 30MHz~300MHz
1GHz-40GHz 1GHz-40GHz 1GHz-40GHz
9kHz-40GHz
1GHz-40GHz
1GHz-40GHz

Uncertainty ±3.10dB ±2.96dB ±3.10dB ±3.80dB ±3.90dB ±1.63dB ±1.60dB ±0.57dB ±1.2dB ±5%
±1.80dB
±2.47dB
±25Hz

Note (1) (1) (1) (1) (1) (1) (1) (1) (1) (1)
(1)
(1)
(1)

(1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 9 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

1.7. Description of Test Modes
The EUT has been tested under operating condition.
This test was performed with EUT in X, Y, Z position and the worst case was found when EUT in X position.
AC conducted emission pre-test at both at AC 120V/60Hz and AC 240V/60Hz modes, recorded worst case.
AC conducted emission pre-test at both at power adapter modes, recorded worst case.
Worst-case mode and channel used for 150 KHz-30 MHz power line conducted emissions was determined to be IEEE 802.11n HT20 MIMO mode (Low Channel).
Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was determined to be IEEE 802.11n HT20 MIMO mode (Low Channel).
Pre-test AC conducted emission at both voltage AC 120V/60Hz and AC 240V/50Hz, recorded worst case.
Worst-Case data rates were utilized from preliminary testing of the Chipset, worst-case data rates used during the testing are as follows: MIMO mode
IEEE 802.11a Mode: 6 Mbps, OFDM.
IEEE 802.11n HT20 Mode: MCS0, OFDM.
IEEE 802.11n HT40 Mode: MCS0, OFDM.
IEEE 802.11ac VHT20 Mode: MCS0
IEEE 802.11ax HEW20 Mode: MCS0
IEEE 802.11ac VHT40 Mode: MCS0, OFDM.
IEEE 802.11ax HEW40 Mode: MCS0, OFDM.
IEEE 802.11ac VHT80 Mode: MCS0, OFDM.
IEEE 802.11ac VHT160 Mode: MCS0, OFDM.
IEEE 802.11 ax HEW 20
IEEE 802.11 ax HEW 40
IEEE 802.11 ax HEW 80
IEEE 802.11 ax HEW 160
802.11ax HEW20_Nss1,(MCS0),RU 26,#RU 0 802.11ax HEW20_Nss1,(MCS0),RU 26,#RU 4 802.11ax HEW20_Nss1,(MCS0),RU 26,#RU 8 802.11ax HEW20_Nss1,(MCS0),RU 52,#RU 37 802.11ax HEW20_Nss1,(MCS0),RU 52,#RU 40 802.11ax HEW20_Nss1,(MCS0),RU 106,#RU 53 802.11ax HEW20_Nss1,(MCS0),RU 106,#RU 54 802.11ax HEW40_Nss1,(MCS0),RU 242,#RU 61 802.11ax HEW40_Nss1,(MCS0),RU 242,#RU 62 802.11ax HEW80_Nss1,(MCS0),RU 484,#RU 65 802.11ax HEW80_Nss1,(MCS0),RU 484,#RU 66 802.11ax HEW160_Nss1,(MCS0),RU 996,#RU 67
802.11ax HEW160_Nss1,(MCS0),RU 996,#RU 195
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 10 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Antenna & Bandwidth

Antenna

Chain0 (Ant0)

Bandwidth Mode

20 M Hz

40 M Hz

80 MH
z

160 MH
z

IEEE 802.11a

 



IEEE 802.11n

 



IEEE 802.11ac

 



IEEE 802.11ax

 



Chain1 (Ant1)

20M Hz

40 MH
z

80 MH
z

160 MHz

  

  

  

  

Chain1 (Ant2) 20 40 80 16 MH MH MH 0M z z z Hz   
  
  
  

Simultane ously /
   

1.8. Channel List and Frequency

Frequency Band

Channel No.

Frequency (MHz)

Channel No.

Frequency (MHz)

149

5745

155

5775

5725MHz~5850MHz

151

5755

159

5795

153

5765

161

5805

157

5785

165

5825

For IEEE 802.11a/n HT20/ac VHT20/ax HEW 20, Channel 149, 157 and 165 were tested.

For IEEE 802.11n HT40/ac VHT40/ax HEW 40, Channel 151 and 159 were tested.

For IEEE 802.11ac VHT80/ax HEW 80, Channel 155 was tested.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 11 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

2. TEST METHODOLOGY
All measurements contained in this report were conducted with ANSI C63.10-2013, American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices. The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd.
2.1. EUT Configuration
The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application.
2.2. EUT Exercise
The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the measurements. According to FCC's request, Test Procedure 789033 D02 General U-NII Test Procedures New Rules v02r01 and KDB 662911 D01 Multiple Transmitter Output v02r01 is required to be used for this kind of FCC 15.407 UII device. According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205, 15.207, 15.209 and 15.407 under the FCC Rules Part 15 Subpart E
2.3. General Test Procedures

2.3.1 Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.

2.3.2 Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane below 1GHz and 1.5 m above ground plane above 1GHz. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 6.3 of ANSI C63.10-2013.

2.4. Test Sample

The application provides 2 samples to meet requirement;

Sample Number Sample 1(A031723030-1)

Description Engineer sample ­ continuous transmit

Sample 2(A031723030-2)

Normal sample ­ Intermittent transmit

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 12 of 42

FCC ID: 2APRGRT02

3. SYSTEM TEST CONFIGURATION

Report No.: LCSA031723030EE

3.1. Justification
The system was configured for testing in a continuous transmits condition.

3.2. EUT Exercise Software
The system was configured for testing in a continuous transmits condition and change test channels by software <QATool_UIv2.78_DLLv6.83_ap_2023-0113> provided by application.

3.3. Special Accessories

No.

Equipment

Manufacturer Model No.

Serial No.

Length

shielded/ unshielded

Notes

/

/

/

/

/

/

/

/

3.4. Block Diagram/Schematics
Please refer to the related document

3.5. Equipment Modifications
Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

3.6. Test Setup
Please refer to the test setup photo.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 13 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

4. SUMMARY OF TEST RESULTS

FCC Rules §15.407(e)
§2.1047 §15.407(a) §15.407(a) §15.209, §15.407(b) §15.407(g)
/
§15.209, §15.407(b) §15.207(a) §15.203
§15.407 §2.1091

Applied Standard: FCC Part 15 Subpart E

Description of Test

Result

6dB Bandwidth

Compliant

99% Occupied Bandwidth

Compliant

Maximum Conducted Output Power

Compliant

Power Spectral Density

Compliant

Emissions in Restricted Bands

Compliant

Frequency Stability

Compliant

On Time and Duty Cycle

/

Radiated Emissions AC Conducted Emissions
Antenna Requirements RF Exposure

Compliant Compliant Compliant Compliant

Remark Appendix E.1
N/A Appendix E.2 Appendix E.3 Appendix E.4 Appendix E.5 Only reported; Appendix E.6
Note 1 Note 1 Note 1 Note 2

Remark: 1. Note 1 ­ Test results inside test report; 2. Note 2 ­ Test results in other test report (RF Exposure report). 3.Note3-For ax mode,partial RU and full RU were tested,the report only recorded the worst result of full RU.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 14 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5. TEST RESULT
5.1. 6dB Occupied Bandwidth Measurement

5.1.1. Standard Applicable Within the 5.725-5.85 GHz band, the minimum 6 dB bandwidth of U-NII devices shall be at least 500 kHz.

5.1.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of the Spectrum Analyzer.

Spectrum Parameter Attenuation Span Detector Trace Sweep Time

Setting Auto > 26dB Bandwidth Peak Max Hold Auto

5.1.3. Test Procedures 1. The transmitter output (antenna port) was connected to the spectrum analyzer in peak hold mode. 2. The resolution bandwidth of 100 KHz and the video bandwidth of 300 KHz were used. 3. Measured the spectrum width with power higher than 6dB below carrier.

5.1.4. Test Setup Layout

5.1.5. EUT Operation during Test
The EUT was programmed to be in continuously transmitting mode.
5.1.6. Test Result of 6dB Occupied Bandwidth
PASS.
Please refer to Appendix E.1
Remark: 1. Measured 6dB bandwidth at difference data rate for each mode and recorded worst case for each mode. 2. Test results including cable loss; 3. Worst case data at MIMO mode 6Mbps at IEEE 802.11a; MCS0 at IEEE 802.11n HT20, IEEE 802.11n
HT40, IEEE 802.11ac VHT20,IEEE 802.11ax HEW20, IEEE 802.11ac VHT40, IEEE 802.11ax HEW40, IEEE 802.11ac VHT80,IEEE 802.11ax HEW80 ;
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 15 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.2. 99% Occupied Bandwidth Measurement

5.2.1. Standard Applicable
According to §2.1049: The occupied bandwidth, that is the frequency bandwidth such that, below its lower and above its upper frequency limits, the mean powers radiated are each equal to 0.5 percent of the total mean power radiated by a given emission shall be measured under the following conditions as applicable.

5.2.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of the Spectrum Analyzer.

Spectrum Parameter Attenuation Span Frequency Detector Trace Sweep Time

Setting Auto > RBW Peak Max Hold 100ms

5.2.3. Test Procedures 1. The transmitter output (antenna port) was connected to the spectrum analyzer in peak hold mode. 2. Set RBW = 1%~5% OBW; VBW3*RBW; 3. Measured the 99% occupied bandwidth by related function of the spectrum analyzer.
5.2.4. Test Setup Layout

5.2.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode.
5.2.6. Test Result of 99% Occupied Spectrum Bandwidth Not Applicable

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 16 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.3. Maximum Conducted Output Power Measurement

5.3.1. Standard Applicable
For 5725~5850MHz
For the band 5.725-5.85 GHz, the maximum conducted output power over the frequency band of operation shall not exceed 1 W. In addition, the maximum power spectral density shall not exceed 30 dBm in any 500-kHz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. However, fixed point-to-point U-NII devices operating in this band may employ transmitting antennas with directional gain greater than 6 dBi without any corresponding reduction in transmitter conducted power. Fixed, point-to-point operations exclude the use of point-to-multipoint systems, omnidirectional applications, and multiple collocated transmitters transmitting the same information. The operator of the U-NII device, or if the equipment is professionally installed, the installer, is responsible for ensuring that systems employing high gain directional antennas are used exclusively for fixed, point-to-point operations.
5.3.2. Measuring Instruments and Setting
Please refer to equipment list in this report. The following table is the setting of the power meter.
5.3.3. Test Procedures
The transmitter output (antenna port) was connected to the power meter.
According to KDB789033 D02 General UNII Test Procedures New Rules v02r01 Section 3 (a) Method PM (Measurement using an RF average power meter):
(i) Measurements may be performed using a wideband RF power meter with a thermocouple detector or equivalent if all of the conditions listed below are satisfied.
 The EUT is configured to transmit continuously or to transmit with a constant duty cycle.
 At all times when the EUT is transmitting, it must be transmitting at its maximum power control level.
 The integration period of the power meter exceeds the repetition period of the transmitted signal by at least a factor of five.
(ii) If the transmitter does not transmit continuously, measure the duty cycle, x, of the transmitter output signal as described in section II.B.
(iii) Measure the average power of the transmitter. This measurement is an average over both the on and off periods of the transmitter.
5.3.4. Test Setup Layout

5.3.5. EUT Operation during Test
The EUT was programmed to be in continuously transmitting mode.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 17 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.3.6. Test Result of Maximum Conducted Output Power Limits

Mode
IEEE 802.11a IEEE 802.11n/ac/ax

Antenna 0 Gain (dBi)
3.92 3.92

PASS

Please refer to Appendix E.2

Antenna 1 Gain (dBi)
4.57 4.57

Antenna 2 Gain (dBi)
4.3 4.3

Directional Gain (dBi)
/ 9.04

Power Limit (dBm)
30 26.96

Remark: 1. Measured output power at difference data rate for each mode and recorded worst case for each mode. 2. Test results including cable loss; 3. Worst case data at MIMO mode 6Mbps at IEEE 802.11a; MCS0 at IEEE 802.11n HT20, IEEE 802.11n
HT40, IEEE 802.11ac VHT20,IEEE 802.11ax HEW 20, IEEE 802.11ac VHT40, IEEE 802.11ax HEW40, IEEE 802.11ac VHT80,IEEE 802.11ax HEW 80 ; 4. Report conducted power = Measured conducted average power + Duty Cycle factor; 5. The EUT used two same PIFA antenna for WIFI TX/RX, the directional gain=2.0+10*log (2) =5.01dBi. 6. For power measurements on IEEE 802.11 devices; Array Gain = 0 dB (i.e., no array gain) for NANT  4; Array Gain = 0 dB (i.e., no array gain) for channel widths  40 MHz for any NANT; Array Gain = 5 log (NANT/NSS) dB or 3 dB, whichever is less, for 20-MHz channel widths with NANT  5.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 18 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.4. Power Spectral Density Measurement
5.4.1. Standard Applicable
For 5725~5850MHz
For the band 5.725-5.85 GHz, the maximum conducted output power over the frequency band of operation shall not exceed 1 W. In addition, the maximum power spectral density shall not exceed 30 dBm in any 500-kHz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum conducted output power and the maximum power spectral density shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. However, fixed point-to-point U-NII devices operating in this band may employ transmitting antennas with directional gain greater than 6 dBi without any corresponding reduction in transmitter conducted power. Fixed, point-to-point operations exclude the use of point-to-multipoint systems, omnidirectional applications, and multiple collocated transmitters transmitting the same information. The operator of the U-NII device, or if the equipment is professionally installed, the installer, is responsible for ensuring that systems employing high gain directional antennas are used exclusively for fixed, point-to-point operations.
5.4.2. Measuring Instruments and Setting
Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.
5.4.3. Test Procedures
1). The transmitter was connected directly to a Spectrum Analyzer through a directional couple.
2). The power was monitored at the coupler port with a Spectrum Analyzer. The power level was set to the maximum level.
3). Set the RBW = 510 kHz
4). Set the VBW  3*RBW
5). Span=Encompass the entire emissions bandwidth (EBW) of the signal
6). Detector = RMS.
7). Sweep time = auto couple.
8). Trace mode = max hold.
9). Allow trace to fully stabilize.
10). If measurement bandwidth of Maximum PSD is specified in 500 kHz, add 10 log (500 kHz/RBW) to the measured result, whereas RBW (<500 kHz) is the reduced resolution bandwidth of the spectrum analyzer set during measurement.
11). If measurement bandwidth of Maximum PSD is specified in 1 MHz, add 10 log (1MHz/RBW) to the measured result, whereas RBW (< 1 MHz) is the reduced resolution bandwidth of spectrum analyzer set during measurement.
12). Care must be taken to ensure that the measurements are performed during a period of continuous transmission or are corrected upward for duty cycle.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 19 of 42 5.4.4. Test Setup Layout

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.4.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode.

5.4.6. Test Result of Power Spectral Density

Limits
Mode
IEEE 802.11a IEEE 802.11n/ac/ax

Antenna 0 Gain (dBi)
3.92 3.92

Antenna 1 Gain (dBi)
4.57 4.57

PASS.

Antenna 2 Gain (dBi)
4.3 4.3

Directional Gain (dBi)
/ 9.04

PSD Limit (dBm/500KHz)
Limit (dBm)
30 26.96

Please refer to Appendix E.3.

Remark: 1. Measured power spectrum density at difference data rate for each mode and recorded worst case for each mode. 2. Test results including cable loss; 3. Worst case data at MIMO mode 6Mbps at IEEE 802.11a; MCS0 at IEEE 802.11n HT20, IEEE 802.11n HT40, IEEE 802.11ac VHT20,IEEE 802.11ax VHT20, IEEE 802.11ac VHT40, IEEE 802.11ax VHT40, IEEE 802.11ac VHT80,IEEE 802.11ax VHT80 ; 4. Report conducted PSD = measured conducted PSD + Duty Cycle factor + RBW factor; 5. RBW factor = 10 log (500 KHz / 300 KHz) = 2.218 dB; 6. The EUT used two same PIFA antenna for WIFI TX/RX, the directional gain=2.04+10*log (2)=5.05dBi. So the power spectrum density limits of IEEE 802.11n HT20, IEEE 802.11 n HT40 for MIMO with CDD technology should be reduced. 7. For MIMO with CCD technology device, The Directional Gain= Gain of individual transmit antennas (dBi) + Array gain; Array gain = 10 log (Nant), where Nant is the number of transmit antennas

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 20 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.5. Emissions in Restricted Bands
5.5.1 Limit
According to 15.407 (b) Undesirable emission limits. Except as shown in paragraph (b) (7) of this section, the maximum emissions outside of the frequency bands of operation shall be attenuated in accordance with the following limits: (a) For transmitters operating in the 5.15-5.25 GHz band: All emissions outside of the 5.15-5.35 GHz band
shall not exceed an e.i.r.p. of -27 dBm/MHz. (b) For transmitters operating in the 5.25-5.35 GHz band: All emissions outside of the 5.15-5.35 GHz band
shall not exceed an e.i.r.p. of -27 dBm/MHz. (c) For transmitters operating in the 5.47-5.725 GHz band: All emissions outside of the 5.47-5.725 GHz
band shall not exceed an e.i.r.p. of -27 dBm/MHz. (d) For transmitters operating in the 5.725-5.85 GHz band:
(i) All emissions shall be limited to a level of -27 dBm/MHz at 75 MHz or more above or below the band edge increasing linearly to 10 dBm/MHz at 25 MHz above or below the band edge, and from 25 MHz above or below the band edge increasing linearly to a level of 15.6 dBm/MHz at 5 MHz above or below the band edge, and from 5 MHz above or below the band edge increasing linearly to a level of 27 dBm/MHz at the band edge.
(ii) Devices certified before March 2, 2017 with antenna gain greater than 10 dBi may demonstrate compliance with the emission limits in §15.247(d), but manufacturing, marketing and importing of devices certified under this alternative must cease by March 2, 2018. Devices certified before March 2, 2018 with antenna gain of 10 dBi or less may demonstrate compliance with the emission limits in §15.247(d), but manufacturing, marketing and importing of devices certified under this alternative must cease before March 2, 2020.
(e) The emission measurements shall be performed using a minimum resolution bandwidth of 1 MHz. A lower resolution bandwidth may be employed near the band edge, when necessary, provided the measured energy is integrated to show the total power over 1 MHz.
(f) Unwanted emissions below 1 GHz must comply with the general field strength limits set forth in §15.209. Further, any U-NII devices using an AC power line are required to comply also with the conducted limits set forth in §15.207.
(g) The provisions of §15.205 apply to intentional radiators operating under this section. (h) When measuring the emission limits, the nominal carrier frequency shall be adjusted as close to the
upper and lower frequency band edges as the design of the equipment permits.
5.5.2 Test Configuration

5.5.3 Test Procedure
1. The power was monitored at the coupler port with a Spectrum Analyzer. The power level was set to the maximum level.
2. Set the RBW = 1MHz. 3. Set the VBW  3MHz 4. Number of points in sweep  2 × span / RBW. (This ensures that bin-to-bin spacing is  RBW/2, so that
narrowband signals are not lost between frequency bins.) 5. Manually set sweep time  10 × (number of points in sweep) × (total on/off period of the transmitted
signal). 6. Set detector = power averaging (rms). 7. Sweep time = auto couple. 8. Trace mode = max hold. 9. Allow trace to fully stabilize.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 21 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.5.4 Test Results PASS
Please refer to Appendix E.4.

Remark: 1. Measured unwanted emission at difference data rate for each mode and recorded worst case for each
mode; 2. Test results including cable loss; 3. Worst case data at MIMO mode 6Mbps at IEEE 802.11a; MCS0 at IEEE 802.11n HT20, IEEE 802.11n
HT40, IEEE 802.11ac VHT20,IEEE 802.11ax HEW 20, IEEE 802.11ac VHT40, IEEE 802.11ax HEW 40, IEEE 802.11ac VHT80,IEEE 802.11ax HEW 80 ; 4. E.I.R.P = Conducted power + Antenna Gain; 5. EIRP calculation. A value representative of an upper bound on out-of-band antenna gain (in dBi) shall be added to the measured antenna-port conducted emission power to compute EIRP within the specified measurement bandwidth. (For emissions in the restricted bands, additional calculations are required to convert EIRP to field strength at the specified distance.) The upper bound on antenna gain for a device with a single RF output shall be selected as the maximum in-band gain of the antenna across all operating bands or 2 dBi, whichever is greater.3 However, for devices that operate in multiple bands using the same transmit antenna, the highest gain of the antenna within the operating band nearest to the out-of-band frequency being measured may be used in lieu of the overall highest gain when measuring emissions at frequencies within 20% of the absolute frequency at the nearest edge of that band, but in no case shall a value less than 2 dBi be selected; 6. Over limit = EIRP ­ Limit;

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 22 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.6. Frequency Stability
5.6.1 Standard Applicable
According to FCC §15.407(g) "Manufacturers of U-NII devices are responsible for ensuring frequency stability such that an emission is maintained within the band of operation under all conditions of normal operation as specified in the users manual."
According to FCC §2.1055(a) "The frequency stability shall be measured with variation of ambient temperature as follows:"
(1) From -30° to + 50° centigrade for all equipment except that specified in paragraphs (a) (2) and (3) of this section.
(2) From -20° to + 50° centigrade for equipment to be licensed for use in the Maritime Services under part 80 of this chapter, except for Class A, B, and S Emergency Position Indicating Radiobeacons (EPIRBS), and equipment to be licensed for use above 952 MHz at operational fixed stations in all services, stations in the Local Television Transmission Service and Point-to-Point Microwave Radio Service under part 21 of this chapter, equipment licensed for use aboard aircraft in the Aviation Services under part 87 of this chapter, and equipment authorized for use in the Family Radio Service under part 95 of this chapter.
(3) From 0°to + 50°centigrade for equipment to be licensed for use in the Radio Broadcast Services under part 73 of this chapter.
5.6.2 Test Configuration

5.6.3 Test Procedure
The equipment under test was connected to an external AC or DC power supply and input rated voltage. RF output was connected to a frequency counter or spectrum anzlyer via feed through attenators. The EUT was placed inside the temperature chamber. Set the spectrum analyzer RBW low engouh to obtain the desired frequency resoluation and measure EUT 20 degree operating frequency as reference frequency. Turn EUT off and set the chamber temperature to -30 degree. After the temperature stabilized for approximately 30 minutes recorded the frequency. Repeat step measure wuth 10 degree increased per stage until the highest temperature of +50 degree reached.
5.6.4 Test Results
PASS
Please refer to Appendix E.5
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 23 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.7. On Time and Duty Cycle
5.7.1. Standard Applicable None; for reporting purpose only.
5.7.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of the spectrum analyzer.
5.7.3. Test Procedures 1. Set the Centre frequency of the spectrum analyzer to the transmitting frequency; 2. Set the span=0MHz, RBW=8.0MHz, VBW=8.0MHz, Sweep time=auto; 3. Detector = peak; 4. Trace mode = Single hold.
5.7.4. Test Setup Layout

5.7.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode.
5.7.6. Test result For reporting purpose only. Please refer to Appendix E.6

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 24 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.8. Radiated Emissions Measurement

5.8.1. Standard Applicable

15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any

of the frequency bands listed below:

MHz

MHz

MHz

GHz

0.090-0.110

16.42-16.423

399.9-410

4.5-5.15

\1\ 0.495-0.505

16.69475-16.69525

608-614

5.35-5.46

2.1735-2.1905

16.80425-16.80475

960-1240

7.25-7.75

4.125-4.128

25.5-25.67

1300-1427

8.025-8.5

4.17725-4.17775

37.5-38.25

1435-1626.5

9.0-9.2

4.20725-4.20775

73-74.6

1645.5-1646.5 9.3-9.5

6.215-6.218

74.8-75.2

1660-1710

10.6-12.7

6.26775-6.26825

108-121.94

1718.8-1722.2 13.25-13.4

6.31175-6.31225

123-138

2200-2300

14.47-14.5

8.291-8.294

149.9-150.05

2310-2390

15.35-16.2

8.362-8.366

156.52475-156.52525 2483.5-2500

17.7-21.4

8.37625-8.38675

156.7-156.9

2690-2900

22.01-23.12

8.41425-8.41475

162.0125-167.17

3260-3267

23.6-24.0

12.29-12.293.

167.72-173.2

3332-3339

31.2-31.8

12.51975-12.52025 240-285

3345.8-3358

36.43-36.5

12.57675-12.57725 322-335.4

3600-4400

(\2\)

13.36-13.41

\1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.

\2\ Above 38.6

For transmitters operating in the 5.725-5.85 GHz band:

All emissions shall be limited to a level of -27 dBm/MHz(68.2dBuV/m at 3m) at 75 MHz or more above or below the band edge increasing linearly to 10 dBm/MHz(105.2dBuV/m at 3m) at 25 MHz above or below the band edge, and from 25 MHz above or below the band edge increasing linearly to a level of 15.6(110.8dBuV/m at 3m) dBm/MHz at 5 MHz above or below the band edge, and from 5 MHz above or below the band edge increasing linearly to a level of 27 dBm/MHz(122.2dBuV/m at 3m) at the band edge.

In addition, In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed.

Frequencies (MHz)
0.009~0.490 0.490~1.705 1.705~30.0
30~88 88~216 216~960 Above 960

Field Strength (microvolts/meter)
2400/F(KHz) 24000/F(KHz)
30 100 150 200 500

Measurement Distance (meters) 300 30 30 3 3 3 3

5.8.2. Measuring Instruments and Setting

Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and receiver.

Spectrum Parameter Attenuation Start Frequency Stop Frequency RB / VB (Emission in restricted band) RB / VB (Emission in non-restricted band)

Setting Auto 1000 MHz 10th carrier harmonic 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 25 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency

Setting Auto 9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG 150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG 30MHz~1000MHz / RB/VB 120kHz/1MHz for QP

5.8.3. Test Procedures
1) Sequence of testing 9 kHz to 30 MHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used. --- If the EUT is a floor standing device, it is placed on the ground. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions. --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation. Premeasurement: --- The turntable rotates from 0°to 315°using 45°steps. --- The antenna height is 1.0 meter. --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all emissions Final measurement: --- Identified emissions during the premeasurement the software maximizes by rotating the turntable position (0°to 360°) and by rotating the elevation axes (0°to 360°). --- The final measurement will be done in the position (turntable and elevation) causing the highest emissions with QPK detector. --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 26 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

2) Sequence of testing 30 MHz to 1 GHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation. Premeasurement: --- The turntable rotates from 0°to 315°using 45°steps. --- The antenna is polarized vertical and horizontal. --- The antenna height changes from 1 to 3 meter. --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to find the maximum of all emissions. Final measurement: --- The final measurement will be performed with minimum the six highest peaks. --- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position (±45°) and antenna movement between 1 and 4 meter. --- The final measurement will be done with QP detector with an EMI receiver. --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 27 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

3) Sequence of testing 1 GHz to 18 GHz
Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation.
Premeasurement:
--- The turntable rotates from 0°to 315°using 45°steps.
--- The antenna is polarized vertical and horizontal.
--- The antenna height scan range is 1 meter to 2.5 meter.
--- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the maximum of all emissions.
Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position (±45°) and antenna movement between 1 and 4 meter. This procedure is repeated for both antenna polarizations.
--- The final measurement will be done in the position (turntable, EUT-table and antenna polarization) causing the highest emissions with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 28 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

4) Sequence of testing above 18 GHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 1 meter. --- The EUT was set into operation. Premeasurement: --- The antenna is moved spherical over the EUT in different polarizations of the antenna. Final measurement: --- The final measurement will be performed at the position and antenna orientation for all detected emissions that were found during the premeasurements with Peak and Average detector. --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 29 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.8.4. Test Setup Layout

Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade form 3m to 1m.
5.8.5. EUT Operation during Test
The EUT was programmed to be in continuously transmitting mode.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 30 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.8.6. Results of Radiated Emissions (9 KHz~30 MHz)

Temperature Test Engineer

23.8 Taylor Hu

Humidity Configurations

52.1% IEEE 802.11a/n/ac

Freq. (MHz)
-

Level (dBuV)
-

Over Limit (dB)
-

Over Limit (dB)
-

Remark See Note

Note:
The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value has no need to be reported.
Distance extrapolation factor = 40 log (specific distance / test distance) (dB); Limit line = specific limits (dBuV) + distance extrapolation factor.

5.8.7. Results of Radiated Emissions (30 MHz~1 GHz)

Temperature Test Engineer

23.8 Taylor Hu

Humidity Configurations

52.1% IEEE 802.11a/n/ac

PASS. The test data please refer to following page.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Horizontal

Page 31 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Vertical

Page 32 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Note: 1). Pre-scan all modes and recorded the worst case results in this report IEEE 802.11n HT20 MIMO mode (Low Channel).(ANT0+ANT1+ANT2) 2). Emission level (dBuV/m) = 20 log Emission level (uV/m). 3). Level = Reading + Factor, Margin = Level­Limit, Factor = Antenna Factor + Cable Loss - Preamp Factor.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 33 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.8.8. Results for Radiated Emissions (1 ­ 40 GHz)

Note: All the modes have been tested and recorded worst mode in the report.

a mode-ant 1-the worst

Channel 149 / 5745 MHz

Freq GHz
17.235 17.235 17.235 17.235

Read Level dBuV 50.12 31.13 40.72 29.49

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 57.03 38.04 47.24 36.01

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -11.17 -15.96 -20.96 -17.99

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Channel 157 / 5785 MHz

Freq GHz
17.355 17.355 17.355 17.355

Read Level dBuV 43.68 30.86 50.30 31.97

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 50.59 37.77 56.82 38.49

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -17.61 -16.23 -11.38 -15.51

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Channel 163 / 5825 MHz

Freq GHz
17.475 17.475 17.475 17.475

Read Level dBuV 45.19 36.80 50.10 37.17

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 52.10 43.71 56.62 43.69

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -16.10 -10.29 -11.58 -10.31

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

IEEE 802.11n HT20MIMO (ANT0+ANT1+ANT2)

Channel 149 / 5745 MHz

Freq GHz
17.235 17.235 17.235 17.235

Read Level dBuV 43.32 30.98 50.10 31.71

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 50.23 37.89 56.62 38.23

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -17.97 -16.11 -11.58 -15.77

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Channel 157 / 5785 MHz

Freq GHz
17.355 17.355 17.355 17.355

Read Level dBuV 46.50 38.24 41.99 30.99

Ant. Fac dB/m
33.21 33.21 32.82 32.82

Pre. Fac dB
35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 53.41 45.15 48.51 37.51

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB
-14.79 -8.85 -19.69 -16.49

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 34 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Channel 163 / 5825 MHz

Freq GHz
17.475 17.475 17.475 17.475

Read Level dBuV 41.89 31.18 49.23 32.56

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 48.80 38.09 55.75 39.08

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -19.40 -15.91 -12.45 -14.92

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

IEEE 802.11ac VHT20MIMO (ANT0+ANT1+ANT2)

Channel 149 / 5745 MHz

Freq GHz
17.235 17.235 17.235 17.235

Read Level dBuV 45.10 37.37 50.97 38.19

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 52.01 44.28 57.49 44.71

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -16.19 -9.72 -10.71 -9.29

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Channel 157 / 5785 MHz

Freq GHz
17.355 17.355 17.355 17.355

Read Level dBuV 41.44 35.78 46.89 34.41

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 48.35 42.69 53.41 40.93

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -19.85 -11.31 -14.79 -13.07

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Channel 163 / 5825 MHz

Freq GHz
17.475 17.475 17.475 17.475

Read Level dBuV 50.03 32.15 40.86 36.59

Ant. Fac dB/m
33.21 33.21 32.82 32.82

Pre. Fac dB
35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 56.94 39.06 47.38 43.11

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB
-11.26 -14.94 -20.82 -10.89

Remark
Peak Average
Peak Average

Pol/Phase
Horizontal Horizontal
Vertical Vertical

IEEE 802.11ax VHT20MIMO (ANT0+ANT1+ANT2)

Channel 149 / 5745 MHz

Freq GHz
17.235 17.235 17.235 17.235

Read Level dBuV 45.57 38.47 43.09 37.38

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 52.48 45.38 49.61 43.90

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -15.72 -8.62 -18.59 -10.10

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Channel 157 / 5785 MHz

Freq GHz
17.355 17.355 17.355 17.355

Read Level dBuV 41.21 31.35 47.25 34.23

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 48.12 38.26 53.77 40.75

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -20.08 -15.74 -14.43 -13.25

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 35 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Channel 163 / 5825 MHz

Freq GHz
17.475 17.475 17.475 17.475

Read Level dBuV 44.78 30.83 44.34 36.73

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 51.69 37.74 50.86 43.25

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -16.51 -16.26 -17.34 -10.75

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

IEEE 802.11n HT40MIMO (ANT0+ANT1+ANT2)

Channel 151 / 5755 MHz

Freq GHz
17.265 17.265 17.265 17.265

Read Level dBuV 50.42 36.89 43.49 34.79

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 57.33 43.80 50.01 41.31

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -10.87 -10.20 -18.19 -12.69

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Channel 159 / 5795 MHz

Freq GHz
17.385 17.385 17.385 17.385

Read Level dBuV 41.48 31.92 41.45 28.47

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 48.39 38.83 47.97 34.99

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -19.81 -15.17 -20.23 -19.01

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

IEEE 802.11ac VHT40MIMO (ANT0+ANT1+ANT2)

Channel 151 / 5755 MHz

Freq GHz
17.265 17.265 17.265 17.265

Read Level dBuV 43.93 36.76 42.44 28.54

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 50.84 43.67 48.96 35.06

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -17.36 -10.33 -19.24 -18.94

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Channel 159 / 5795 MHz

Freq GHz
17.385 17.385 17.385 17.385

Read Level dBuV 45.70 38.16 41.67 33.82

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 52.61 45.07 48.19 40.34

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -15.59 -8.93 -20.01 -13.66

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

IEEE 802.11ax VHT40MIMO (ANT0+ANT1+ANT2)

Channel 151 / 5755 MHz

Freq GHz
17.265 17.265

Read Level dBuV 45.93 33.76

Ant. Fac dB/m 33.21 33.21

Pre. Fac dB 35.82 35.82

Cab.Los dB
9.52 9.52

Measured Level dBuV 52.84 40.67

Limit Line dBuV/m 68.20 54.00

Over limit dB -15.36 -13.33

Remark Pol/Phase
Peak Horizontal Average Horizontal

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 36 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

17.265 17.265

49.99 37.12

32.82 35.82 9.52 32.82 35.82 9.52

56.51 43.64

68.20 -11.69 Peak Vertical 54.00 -10.36 Average Vertical

Channel 159 / 5795 MHz

Freq GHz
17.385 17.385 17.385 17.385

Read Level dBuV 42.76 37.57 49.60 29.41

Ant. Fac dB/m 33.21 33.21 32.82 32.82

Pre. Fac dB 35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measured Level dBuV 49.67 44.48 56.12 35.93

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -18.53 -9.52 -12.08 -18.07

Remark Pol/Phase

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

IEEE 802.11ac VHT80MIMO (ANT0+ANT1+ANT2)

Channel 155 / 5775 MHz

Freq GHz
17.325 17.325 17.325 17.325

Read Level dBuV 43.65 36.81 41.85 30.00

Ant. Fac dB/m
33.21 33.21 32.82 32.82

Pre. Fac dB
35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measur ed Level
dBuV 50.56 43.72 48.37 36.52

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -17.64 -10.28 -19.83 -17.48

Remark

Pol

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

IEEE 802.11ax VHT80MIMO (ANT0+ANT1+ANT2)

Channel 155 / 5775 MHz

Freq GHz
17.325 17.325 17.325 17.325

Read Level dBuV 41.89 28.23 47.12 38.38

Ant. Fac dB/m
33.21 33.21 32.82 32.82

Pre. Fac dB
35.82 35.82 35.82 35.82

Cab.Los dB
9.52 9.52 9.52 9.52

Measur ed Level
dBuV 48.80 35.14 53.64 44.90

Limit Line dBuV/m 68.20 54.00 68.20 54.00

Over limit dB -19.40 -18.86 -14.56 -9.10

Remark

Pol

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Notes:

1). Measuring frequencies from 9 KHz ~ 40 GHz, No emission found between lowest internal used/generated frequency to 30MHz. 2). Radiated emissions measured in frequency range from 9 KHz ~ 40 GHz were made with an instrument using Peak detector mode. 3). 18~40GHz at least have 20dB margin. No recording in the test report. 4). Worst case data at 6Mbps at IEEE 802.11a; MCS0 at IEEE 802.11n HT20, IEEE 802.11n HT40, IEEE 802.11ac VHT20,IEEE 802.11ax HEW 20, IEEE 802.11ac VHT40, IEEE 802.11ax HEW 40, IEEE 802.11ac VHT80,IEEE 802.11ax HEW 80; 5). Data of measurement within this frequency range shown "---" in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured.
6). Pre-scan at Antenna 0 and Antenna1 and Antenna 2, Antenna 0 + Antenna 1+ Antenna 2 modes, recorded worst case.
7). Measured Level = Reading Level + Factor, Over = Measured Level ­ Limit, Factor = Antenna Factor + Cable Loss - Preamp Factor.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 37 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.9. Power Line Conducted Emissions

5.9.1 Standard Applicable

According to §15.207 (a): For an intentional radiator which is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at specific frequency range are listed as follows:

Frequency Range (MHz)
0.15 to 0.50 0.50 to 5 5 to 30

Limits (dBV) Quasi-peak
66 to 56* 56 60

Average 56 to 46*
46 50

* Decreasing linearly with the logarithm of the frequency

5.9.2 Block Diagram of Test Setup

5.9.3 Test Results Temperature Test Engineer

23.3 Taylor Hu

Humidity Configurations

PASS. The test data please refer to following page.

53.1% IEEE 802.11a/n/ac

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 38 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

Line

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Neutral

Page 39 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

***Note: Pre-scan all modes and recorded the worst case results in this report IEEE 802.11n HT20 MIMO mode (Low Channel).(ANT0+ANT1+ANT2) Measurement = Reading + Correct Factor, Margin = Measurement ­ Limit, Correct Factor=Lisn Factor+Cable Factor.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 40 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

5.10. Antenna Requirements
5.10.1 Standard Applicable
For intentional device, according to FCC 47 CFR Section 15.203:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited
And according to FCC 47 CFR Section 15.407 (a), if transmitting antennas of directional gain greater than 6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6dBi.
5.10.2 Antenna Connected Construction
5.10.2.1. Standard Applicable
According to §15.203 & RSS-Gen, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device.
5.10.2.2. Antenna Connector Construction
The max gains of antenna used for transmitting is 4.57dBi(Max), and the antenna is an External Antenna connect to PCB board and no consideration of replacement. Please see EUT photo for details, meet FCC Part 15.203 antenna requirement.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 41 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

6. LIST OF MEASURING EQUIPMENTS

Item

Equipment

Manufacturer

1

Power Meter

R&S

2

Power Sensor

R&S

3

Power Sensor

R&S

4

Test Software

Tonscend

5

RF Control Unit

Tonscend

6

MXA Signal Analyzer

Agilent

7

DC Power Supply

Agilent

8

EMI Test Software

9 3m Semi Anechoic Chamber

AUDIX
SIDT FRANKONIA

10

Positioning Controller

Max-Full

11

Active Loop Antenna

SCHWARZBECK

12

By-log Antenna

SCHWARZBECK

13

Horn Antenna

SCHWARZBECK

14 Broadband Horn Antenna SCHWARZBECK

15

Broadband Preamplifier

SCHWARZBECK

16

EMI Test Receiver

R&S

17 RS SPECTRUM ANALYZER

R&S

18

Broadband Preamplifier

/

19

6dB Attenuator

/

20

3dB Attenuator

/

21

EMI Test Receiver

R&S

22

Artificial Mains

R&S

23

10dB Attenuator

SCHWARZBECK

24

EMI Test Software

Farad

Model No. NRVS
NRV-Z81 NRV-Z32 JS1120-2 JS0806-2 N9020A E3642A
E3
SAC-3M
MF7802BS FMZB 1519B
VULB9163 BBHA 9120D BBHA 9170
BBV9719 ESR 7 FSP40
BP-01M18G 100W/6dB
2N-3dB ESPI
ENV216 MTS-IMP-136
EZ

Serial No. 100444 100458 10057 / N/A
MY50510140 N/A /

Cal Date 2022-06-16 2022-06-16 2022-06-16
N/A 2022-10-29 2022-10-29 2022-10-29
N/A

03CH03-HY

2022-06-16

MF780208586 00005
9163-470 9120D-1925
791 9719-025 101181 100503 P190501 1172040
/ 101940 101288 261115-001-0032
/

N/A 2021-08-29 2021-09-12 2021-09-05 2021-08-29 2022-06-16 2022-06-16 2022-10-29 2022-06-16 2022-06-16 2022-10-29 2022-08-18 2022-06-16 2022-06-16
N/A

Due Date 2023-06-15 2023-06-15 2023-06-15
N/A 2023-10-28 2023-10-28 2023-10-28
N/A
2023-06-15
N/A 2024-08-28 2024-09-11 2024-09-04 2024-08-28 2023-06-15 2023-06-15 2023-10-28 2023-06-15 2023-06-15 2023-10-28 2023-08-17 2023-06-15 2023-06-15
N/A

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webmaster@lcs-cert.com | Web: www.lcs-cert.com Scan code to check authenticity

Page 42 of 42

FCC ID: 2APRGRT02

Report No.: LCSA031723030EE

7. TEST SETUP PHOTOGRAPHS OF EUT
Please refer to separated files for Test Setup Photos of the EUT.
8. EXTERIOR PHOTOGRAPHS OF THE EUT
Please refer to separated files for External Photos of the EUT.
9. INTERIOR PHOTOGRAPHS OF THE EUT
Please refer to separated files for Internal Photos of the EUT.

----------------THE END OF REPORT---------------