ℹ️ Document Conversion Notice: This page was converted from the original file for easier reading. Diagrams/images may appear only in the original PDF below.
Document preview
File info: application/pdf · 2 pages · 1.47MB

Ultrasonic Clear Label Sensor (Model CLS-1)

This document provides installation and setup instructions for the TRI-TRONICS CLS-1 Ultrasonic Clear Label Sensor.

Specifications

Feature Details
Supply Voltage 12 to 30 VDC (Polarity Protected; for Class 2 Circuits)
Current Requirements 95mA @ 12 VDC, 45mA @ 30 VDC
Digital Outputs (1) NPN and (1) PNP open collector, 150mA Max; <2V Residual Voltage. (NPN & PNP software selectable on CLSC-1M8). All outputs short circuit protected.
Remote AUTOSET Input Momentary sinking or sourcing input; 1.2mA max; Software Selectable.
Diagnostic Indicators OLED Graphic Display (Contrast, Numerical Display, Set Point, Trigger Point, options, modes). Red LED Output Indicator (illuminates when output is ON; flashes on short circuit/overload).
Pushbutton Control Three buttons: Gap (for Gap AUTOSET), Label (for multi-layered labels), Menu (for accessing Options).
Hysteresis Dynamic - adjusted by AUTOSET.
Response Time 200μs
Repeatability 125μs
Ambient Temperature 4°C to 50°C (39°F to 122°F)
Rugged Construction Chemical resistant, high impact Aluminum housing. Waterproof ratings: NEMA 4X, 6P, and IP65. Conforms to heavy industry grade CE requirements.
Output Timers (Advanced Option) On Delay, Off Delay, One Shot, or Debounce (software selectable).
Threshold Set 1-Point, 2-Point, or Dynamic AUTOSET; manually or remotely.
Threshold Adjust Manual or AUTO Adjust.
Connector M12 5-Pin, M8 4-Pin, or 6' (1.8m) Shielded Cable.

Note: RoHS Compliant. Product subject to change without notice.

Connections and Dimensions

The sensor is available in M12 and M8/M8LE models, with either a connector or a 6' (1.8m) shielded cable.

Wiring Configurations:

  • M12 5-Pin Connector: Brown (1) - Positive, White (2) - NPN, Blue (3) - Negative, Black (4) - PNP, Gray (5) - Remote AUTOSET.
  • M8 4-Pin Connector: Brown (1) - Positive, White (2) - Remote AUTOSET, Blue (3) - Negative, Black (4) - Output.
  • M8LE 4-Pin Connector: Brown (1) - Positive, White (2) - NPN, Blue (3) - Negative, Black (4) - PNP.

Output Configuration Notes:

  • NPN (Sinking) Output: Load terminated to positive. Input activated by connecting to negative.
  • PNP (Sourcing) Output: Load terminated to negative. Input activated by connecting to positive.

Dimensions:

Detailed diagrams show physical dimensions for M12 and M8/M8LE models. Key dimensions include overall height, width, and mounting hole locations. For example, M12 models are approximately 4.522" [114.86mm] in height, while M8/M8LE models are approximately 4.181" [106.20mm] or 4.332" [110.03mm] in height.

Installation Manual

Setup Instructions

The sensor features an OLED Graphic Display and three pushbutton controls.

  • Display Elements: Contrast Indicator, Label Position indicator, Signal Strength indicator, Threshold Number display, Output ON indicator (for Gap or Label), and AUTO Adjust Mode indicator.

Simple Setup

Gap AUTOSET: Place the label gap in view. Press and hold the AUTOSET/GAP button for two seconds. "Gap Set" will be displayed, indicating a successful setup.

Label AUTOSET: If false triggers occur, place the label in view. Push and hold the AUTOSET/LABEL button for two seconds. "Label Set" will be displayed. This two-point setup creates a new threshold for a more consistent signal span.

Alignment Guidance

  • Align Label to Arrow: Place the label web so it is centered on the arrow where the transducers are aligned.
  • Align Gap to Line: Place the label gap in the center of the sensor using the alignment line. View from the top and use the output LED to center the label gap.
  • Gentle Tension: Place label webbing so it slides along the bottom of the sensor gap plate for consistent setup and performance.

Output Indicators

  • A Red LED illuminates when the sensor's output transistors are "ON".
  • The Red LED flashes when a short circuit or overload is detected. If the output LED flashes on power up, a short circuit condition exists.

Button Functions

  • AUTOSET/GAP Button:
    • 1. Push and Hold with gap in view for 2 seconds for AUTOSET.
    • 2. Tap for UP on Contrast Indicator, or reduce threshold.
    • 3. Change settings in MENU options.
  • AUTOSET/LABEL Button:
    • 1. Push and Hold with label in view after GAP AUTOSET (useful for multi-layered labels).
    • 2. Tap DOWN on Contrast Indicator, or increase threshold.
    • 3. Change settings in MENU options.
  • MENU Button:
    • 1. Scroll through MENU options.
    • 2. Hold during power up for additional Menu Options: Timer and Factory Diagnostics (Sensor Scope).

OLED Numerical Display

  1. 1 to 10 bar Contrast Indicator.
  2. Numerical display for threshold and feedback number.
  3. Options Status Display: Button Lock or Unlock (?), auto adjust on/off (AUTO), output in Gap [gap-symbol] or on Label [label-symbol].
  4. View Menu Options.

Note: Sensor is shipped with a protective plastic covering for the display. Remove for clearer viewing.

Detailed Setup (Using Menu Button)

Access advanced setup options by pressing the MENU button.

  1. Initiate Dynamic Set

    Press ⬆️ or ⬇️ button to start a Dynamic Set. Pull labels and gaps through the sensor. Press ⬆️ or ⬇️ to complete. The sensor exits to run mode and should be ready for operation.
  2. Auto Adjust

    Change from OFF to ON by momentarily pressing either the ⬆️ or ⬇️ button. The Auto Adjust evaluates signal levels and makes automatic adjustments to keep the sensor in optimum response levels.
  3. Output Mode

    Change from GAP [gap-symbol] to LABEL [label-symbol] by momentarily pressing either the ⬆️ or ⬇️ button. The output will toggle back and forth in this mode.
  4. Display Orientation

    Momentarily press either the ⬆️ or ⬇️ button to toggle orientation.
  5. Timer Mode (Advanced Option)

    • Off Delay: Outputs stay on for a set time after the duration of input.
    • On Delay: Outputs turn on when the input exceeds the set time.
    • One Shot: Outputs turn on for a set time when triggered by input.
    • Debounce: Outputs are stabilized and held in the current state for the duration of the time setting.
  6. Button Lockout

    Momentarily press either the ⬆️ or ⬇️ button to toggle from Lock ? to Unlock ?. Useful for tamper-free operation.
  7. Quick Reference

    Press the ⬇️ button to scroll down through simple setup and options instructions. Press the ⬆️ button to scroll up.
  8. Sensor Scope (Advanced Option)

    This option allows the operator to visually inspect the current setup for repeatability. The sensor scope will also reveal any nominal setup issues or sensitivities to label or gap thickness changes.
    • Momentarily press the ⬇️ button to shorten the time between signals.
    • Momentarily press the ⬆️ button to lengthen the time between signals.

How to Specify

  1. Select Sensor: Ultrasonic Clear Label Sensor
  2. Select Cable:
    • Blank = 6' (1.8m) Cable
    • C = Connector M12, 5-Pin (Standard)
  3. Select Connector:
    • -1 = Standard M12 Connector (Includes both NPN and PNP)
    • -1M8 = M8, 4-Pin Connector (NPN/PNP Software Selectable)
    • -1M8LE = Wired like LER

Example: Ultrasonic Clear Label Sensor, Blank Cable, -1 Connector = CLS C -1

Advanced Options

To access Advanced Options, press and hold the MENU button during power up.

Press the MENU button to move from screen to screen. Press either the ⬆️ or ⬇️ button to select.

Factory Reset

Press either the ⬆️ or ⬇️ button to initiate factory reset. Note: Advanced Option screen will time out in 5 minutes.

Input Mode (-1, -1M8 models only)

Press either the ⬆️ or ⬇️ button to toggle to PNP / Source or NPN / Sink.

Timer Features

Press either the ⬆️ or ⬇️ button to toggle to Enable or Disable.

Factory Diagnostics/Sensor Scope

Press either the ⬆️ or ⬇️ button to toggle to Enable or Disable.

Returns to Main Screen.

Remote Input Signals

  • Gap Set: Pulse once, 40ms to 400ms.
  • Label Set: Pulse twice, 40ms to 400ms, with 40ms to 400ms idle time between pulses.
  • Dynamic Set: Hold Remote Input ON for more than 750ms, pull labels and gaps through sensor, release Remote Input line and sensor returns to Run mode.

Note: Waveforms shown correspond to PNP input mode.

TRI-TRONICS

P.O. BOX 25135, TAMPA, FL 33622-5135

813-886-4000 / 800-237-0946

ttco.com / info@ttco.com

Logicbus Inc. | 863 BOWSPRIT ROAD, CHULA VISTA, CA 91914, U.S.A. | PHONES: (619) 616 7350, WWW.LOGICBUS.COM

Models: CLS-1 UltraSonic Clear LabelSensor, CLS-1, UltraSonic Clear LabelSensor, Clear LabelSensor, LabelSensor

Original Document

If the viewer doesn’t load, open the PDF directly.