INSTALLATION AND OPERATIONS MANUAL
- READ AND SAVE THESE INSTRUCTIONS -
Patent Pending
Specifications subject to change without notice.
AlorAirSolutionsINC.

Safety Notes
Your Storm Series dehumidifier must be maintained and serviced by qualified technicians. Storm dehumidifiers are intended for use only when the unit is installed in a level and upright position. Operating the unit in any other position could cause water to come in contact with the electrical components.
If the inside of the machine has gotten wet for any reason, the unit should be opened and allowed to dry thoroughly before reconnecting it to electric and restarting.
Do not insert any objects or fingers into the inlet or discharge. Do not spray water or cleaner directly on the exterior of the unit. Only use a damp cloth to clean the exterior and always unplug the unit first. Do not use unit as shelf or device to hang clothes as this could cause damage to unit. Do not stand on the machine.

Table of Contents
Introduction..................................................................................... 01 Unit Overview.................................................................................. 03 LCD Display Introducti.o..n....................................................................04 Preparing the Unit for Use................................................................. 09 Maintenance & Repair....................................................................... Storing Your Dehumidifier.................................................................. 15
............................................................................... 15 Warranty......................................................................................... 17

If an E4 code appears on the display: 1. Reset the unit by disconnecting the power cord and then reconnecting it. NOTE: The unit will not function until the code has been cleared.
4. Replace the hoses and/or pump, if maintenance alone isn't sufficient.

Identification

Introduction

Model Name: Serial Number:

Date of Purchase:

Customer Service
For additional questions concerning the operation fo your dehumidifier, please
Contact AlorAir Solutions:1-888-990-7469

Features
85 Pints Per Day High COP: 2.88 L/Kwh Only 58 dBA Automatic Humidistat Built-in Pump with Overflow Protection Self Monitoring System Eco-Friendly R410A Refrigerant Easy Access to Internal Components Auto Restart After a Power Outage. The Unit can be Ducted on the Supply/Outlet, if Necessary

Electrical Supply
WARNING 240 Volts may cause serious injury from electric shock.

Power Supply:

115V, 60 Hz AC Only 1 Phase

Outlet Requirement: 3-Prong, GFI

Circuit Protector:

15 Amp Time Delay Fuse or Circuit Breaker

1. Disconnect electrical power before servicing 3. Do not use an extension cord 2. Only plug unit into grounded electrical outlet 4. Do not use a plug adapter

Installation

.

Place the Pro in your desired location. The inlet of the machine should be at least 8"

from any obstructions. If the unit has been transported in a horizontal position, allow it to

sit in an upright position for at least 30 minutes before operating.

WARNING
Do not use dehumidifier in an environment where corrosive or high VOC materials are applied.

If you plan on storing your dehumidfier for an extended period of time:

1. Turn unit off and allow to dry. 2. Manually drain pump reservoir. 3. Wrap and secure the power cord.

4. Clean the filter. 5. Store in clean,dry environment.

Troubleshooting

Symptom
Display is Blank No Airflow
Error Code: E1 Error Code: E4 Error Code: LO Error Code: HI E5 Error Code

Cause
Poor Connection Power Outage Filter is Dirty Air lnlet or OutletisBlocked
HumiditySensoror
Communication Error
Problem with Pump

Solution
Power cord are plugged in Reset power
Clean the filter
Clear the blockage
Check to ensure that the sensor wire is connected at both ends. if no issues are visible, the sensor may be faulty.

Room Temperature is below 33.8 o
o
Refrigerant Leak

Increase the room temperature so it is within operating range (above 33.8o ). If error still displays, check sensor.
o

Advanced Pump Cleaning:
1. a. Use the manual pump button (PURGE), to drain any water from reservoir. b. Unplug the unit, and remove pump from reservoir (see page 13). c. Use a wet dry vac or paper towels to remove any remaining water from the pump reservoir.
2. Fill the pump reservoir with cleaning solution (15 oz water / 1 oz bleach or 12 oz water /4 oz white vinegar).
3. Reassemble the pump and use the manual pump button to flush the mixture through the discharge tubing.
4. Mix another batch of cleaning solution then pour it slowly into drain pan under evaporator coil and allow it to clean the hose from pan to pump. This process can be stopped when the pump energizes 1 time. NOTE: If you get any bleach/water mixtureon coils, flush with water.
5. Pour sufficient clean water through the drain pan so that the pump activates twice (16-32 ounces).
6. Reassemble the unit and return it to operational status.
Cleaning the Coils
The coils on your dehumidifier also need to be cleaned once per year. To clean, simply spray with a self-rinsing, foaming coil cleaner (such as WEB Coil Cleaner).

Front View

Unit Overview

Front Cover Air Filter

Air Inlet

Handle Access Latch
Wheel

Air Outlet

LCD Display Power Cord

LCD Display Instructions
PPUUPRRUGGREGE E
1. When the machine is powered on but not working: (After power on, the buzzer makes a sound)
2. Main interface display of dehumidification state:
The following information is displayed when the machine is working: 000 JOB HRS:

Access screws for electrical compartment
Cover
Pump
Integral Pump Maintenance
NOTE: This pump requires routine maintenance that is not covered by your 1 year parts warranty. Only a defective pump will be repaired or replaced under the warranty.
. The pump is designed with quick connection construction, making it easy to access the pump and components for service and maintenance. To Remove Pump from Reservoir: 1. Unplug the unit. 2. Open the back housing as shown on page 12. 3. Remove the condensate tube from the pump. 4. Use the quick connect fittings to disconnect the main power and float switch electrical cables. 5. Use a flathead screw driver to gently pry the the pump off the reservoir.
Basic Pump Cleaning: 1. Press the pump button (PURGE) to drain any water from reservoir. 2. Disconnect power to the dehumidifier. 3. Mix a 16 oz cleaning solution of one of the following: 1 oz bleach / 15 oz water or 4 oz white vinegar / 12 oz water. Pour the solution into the drain tray at the base of the coils. NOTE: If you get any cleaning solution on the coils, flush with water
5. Reconnect power to dehumidifier. 6. Pour clean water into reservoir so the pump activates twice (about 16-32 oz. water).

Accessing Internal Components
WARNING Always unplug unit prior to performing any maintenance.
1. Remove the screws from the side latches (one per side).
Remove the screw and open the latch (one per side) 2. Undo the two latches on the base of the unit by pressing in the safety then opening the latch.
Squeeze safety and open latch
3. Lift open front housing.
Lift to Open

000 LIFE HRS: Refers to the total working time, i.e. the total working time (hours), which is in hours. (Press the mode key + select the confirmation key, and the total working time will be cleaned after 3 seconds.)
IN/OUT 00 00% 00 gr / lb:
Set 00%: Indicates set humidity.
If the main interface does not operate for 10 minutes, the screen will go out.Press any key to wake up.
Other icons light up or flicker when opened The total working time is the accumulation of each working time (hours) in hours. (Press the mode key + select to confirmation key, and the total working time will be cleaned after 3 seconds.
3.Dehumidification status submenu interface display
3.1

"Indicates":Do I need to clear out this time?",

press ">"if you need to clear. When the operation

3.2

is completed, the working time of the main interface and the working time of this interface

will be reset and started to be instant again.

After accumulation (9999), clean up and round.

"Coil Temp 000 ": Used to display the current

3.3

temperature of the coil.When it is below zero, the "-" symbol is displayed in front. "-" is not

required on zero.