Majestic Quartz 36 Platinum Direct Vent Gas Fireplace Specifications
This document outlines the key specifications for the Majestic Quartz 36 Platinum Direct Vent Gas Fireplace.
Product Overview
The Majestic Quartz 36 Platinum is a direct vent gas fireplace designed for efficient and safe heating. It offers various installation and clearance requirements detailed below.
Actual Dimensions
Dimension | Measurement (Inches [mm]) |
---|---|
Front Width | 41" [1041] |
Height | 37-7/8" [962] |
Depth | 16-5/16" [414] |
Glass Size | 32-1/16" x 21-1/12" [814 X 546] |
BTU/Hour Input (NG) | 15,000 - 30,500 BTUs |
BTU/Hour Input (LP) | 15,000 - 29,500 BTUs |
Framing Dimensions
Dimension | Measurement (Inches [mm]) |
---|---|
Front Width | 42" [1067] |
Height | 38-1/4" [972] |
Depth | 16-1/4" [413] |
Weight | 145 LBS [66 KGS] |
Note: Adjust framing dimensions for interior chase sheathing (such as sheetrock).
Clearances and Projections
Combustible Mantel Legs or Wall Projections
Top View: Minimum 1/2" clearance from vent cap to overhang. Minimum 2-7/8" clearance from fireplace opening. Maximum 36" from fireplace opening.
Combustible Mantel Projections
Diagram Description: Illustrates minimum vertical and maximum horizontal dimensions of combustibles relative to the fireplace opening and ceiling. Measurements are taken from the top of the opening.
Non-Combustible Mantel Projections
Diagram Description: Illustrates minimum vertical and maximum horizontal dimensions of non-combustibles relative to the fireplace opening and ceiling. Measurements are taken from the top of the opening.
Non-Combustible Mantel Legs or Wall Projections
Top View: Minimum 3" clearance from fireplace opening. Maximum 6" horizontal projection. Unlimited vertical projection.
Basic Corner Installation
Diagram Description: Shows measurements for basic corner installation, including dimensions for DVP pipe (10" [254]) and SLP pipe (8-5/8" [245]). Reference the install manual for additional venting scenarios.
Exterior Chase Minimum Height Requirements
Diagram Description: Details the minimum height requirements for an exterior chase. Key measurements include:
- C = 46-1/4" from bottom of appliance to combustible surface.
- D = 3" MIN. from top of vent pipe to combustible surface.
- Note on overhang: If overhang "A" is less than 2", clearance "B" must be a minimum of 4". If "A" is greater than 2", consult the installation manual.
Wall Penetration
Diagram Description: Illustrates wall penetration for vent framing. Important note: DO NOT PACK VENT FRAMING HOLE WITH INSULATION OR OTHER MATERIAL. The diagram shows dimensions for a 10" x 10" hole, with the center of the hole 1" [25mm] above the center of the horizontal vent pipe.
Product Listing Codes
Region | Code |
---|---|
US | ANSI Z21.88-2014 |
CAN | CSA 2.33-2014 |
CULUS LISTED | UL307B |
Product information is subject to change without notice. Installation must adhere strictly to accompanying instructions to avoid risk of fire and potential injury.
Heat Management and Venting
For heat management, refer to the fireplace installation manual for framing guidelines and reduced mantel clearances. Additional information on venting, TV clearances, finishing requirements, and fronts can be found in the installation and owner's manual.