Fuses

PDF preview unavailable. Download the PDF instead.

SMB fuse replacement
Power Cable/Fuse Replacement

This document describes how to change the power cord and fuse on a SmartBits chassis when using the Power Cable/Fuse Kit that is shipped with the chassis.
The Power Cable/Fuse Kit contains the power cable and fuses that should be used for international operation (other than U.S.A.) in a SmartBits chassis, in compliance with safety requirements. Each SmartBits chassis is shipped with the default U.S.A. fuses installed.

Fuse Amperage Information

Table 1 lists the fuse amperage specified for each SmartBits chassis.

Table 1. Fuse Amperage for SmartBits Chassis

Chassis

Fuse Amperage U.S.A.

Fuse Amperage International

SmartBits 200
SmartBits 10 SmartBits 2000

2 Amp. 3.15 Amp.

1 Amp. 2 Amp.

SmartBits 600 SmartBits 6000B

2 Amp. 10 Amp.

1 Amp. 5 Amp.

P/N 340-1228-001 Rev B, 2/03

Power Cable/Fuse Replacement | 1

Power Cable/Fuse Replacement Chassis Fuse Location

Chassis Fuse Location

The power supply inlet switch is the main disconnect device and is located on the rear of each SmartBits chassis. It houses the power switch, fuse holder, and a universal 3-wire instrument power cord jack. The power supply connector in each SmartBits chassis has a universal input that accepts 120/240 VAC and requires no selection or adjustment.

Warning: To comply with safety regulations, always make sure that the chassis is powered off and disconnected when removing or inserting fuses.
Figure 1 shows the location of the power supply inlet switch on each SmartBits chassis.

SMB-200

SMB-10/SMB-2000

Power Supply Inlet Switch SMB-600

SMB-6000B

Power Supply Inlet Switch
Figure 1. Location of Power Supply Inlet Switch

Types of Power Supply Inlet Switches

There are two types of power supply inlet switches used in the SmartBits chassis. One type is used with the SMB-10, SMB-200, SMB-2000, and SMB-600 chassis and is described on page 3. The other type is used in the SMB-6000B and is described on page 4.
The fuse holder is located within the power supply inlet switch (see Figure 2). Use a small, flat-head screwdriver to open the fuse holder for each switch.

Power Supply Inlet Switch for the SMB-10, SMB-200, SMB-2000, and SMB-600
Slot Fuse Holder

Slot Fuse Holder

Power Supply Inlet Switch for the SMB-6000B

The dotted line shows the fuse holder located under the cover.

Figure 2. Fuse Holder Location on the Power Supply Inlet Switches

2 | Power Cable/Fuse Replacement

P/N 340-1228-001 Rev B, 2/03

Power Cable/Fuse Replacement Installing a Chassis Fuse
Installing a Chassis Fuse
The installation of a SmartBits chassis fuse varies based on the chassis model. Refer to the appropriate procedure below to install the fuse for your SmartBits chassis model.
SMB-10, SMB-200, SMB-2000, and SMB-600 Power Supply Inlet Switch
To remove or change a fuse: 1 If your chassis is operating, power down the chassis and disconnect the power supply
cable from its power source. 2 Insert the screwdriver in the fuse holder assembly slot shown in Figure 3 and pry the
fuse holder open.
Power Supply Inlet Switch (SMB-10/200/2000/600) Slot
Fuse Holder Assembly (slides out)
Figure 3. Fuse Holder Assembly Slot Location on the Power Supply Inlet Switch (SMB-10/200/2000/600)
3 Slide the fuse holder assembly out of the power supply inlet switch. 4 Locate the fuse that is attached to the bottom of the fuse holder assembly shown in
Figure 4.

Fuse Holder Assembly

Fuse Location

Figure 4. Fuse Holder Assembly Removed from the Power Supply Inlet Switch

P/N 340-1228-001 Rev B, 2/03

Power Cable/Fuse Replacement | 3

Power Cable/Fuse Replacement Installing a Chassis Fuse
5 Remove the fuse and replace it with the international fuse provided in the Power Cable/Fuse Kit.
6 Replace the fuse holder assembly by sliding it back into the power supply inlet switch until it snaps into its proper position.
7 Connect the new international power supply cable provided in the Power Cable/Fuse Kit.
Note: In the fuse holder assembly, there is a small compartment that slides open (see Figure 5). This is used to hold a spare fuse. To open the compartment, use a pointed instrument (such as a pencil) and push the compartment out from either end.

Spare Fuse Compartment
Figure 5. Spare Fuse Compartment in the Fuse Holder Assembly SMB-6000B Power Supply Inlet Switch

To remove or change a fuse:

1 If your chassis is operating, power down the chassis and disconnect the power supply cable from its power source.
2 Insert the screwdriver in the cover slot as shown in Figure 6 and pry open the cover.

Slot

Power Supply Inlet Switch

(SMB-6000B)

Cover opens downward

Figure 6. Fuse Holder Assembly Cover Slot Location on a Power Supply Inlet Switch (SMB-6000B)

4 | Power Cable/Fuse Replacement

P/N 340-1228-001 Rev B, 2/03

Power Cable/Fuse Replacement Installing a Chassis Fuse

3 Use the screwdriver again and place it in the slot at the top of the red fuse holder assembly (Figure 7), then pry the assembly out.

Slot

Power Supply Inlet Switch

(SMB-6000B)

Fuse Holder Assembly (slides out)
Figure 7. Fuse Holder Assembly Slot Location (SMB-6000B) 4 Slide the fuse holder assembly out of the power supply inlet switch. 5 Locate the fuse that is attached to the side of the fuse holder (Figure 8).
Fuse Location
Figure 8. Fuse Location in the Fuse Holder Assembly 6 Remove the fuse and replace it with the international fuse provided in the Power
Cable/Fuse Kit. 7 Replace the fuse holder assembly by sliding it back into the power supply inlet switch
until it snaps into its proper position. 8 Close the cover of the switch until it snaps shut. 9 Connect your new international power supply cable provided in the Power Cable/Fuse
Kit.

P/N 340-1228-001 Rev B, 2/03

Power Cable/Fuse Replacement | 5

