Secop NL9CN Compressor

Single Pack Details

Single Pack Code Number: 195B4540

Single Pack Components

PositionTitleCodeAmount
1Compressor NL9CN105H68561
2Starting relay117U70021
3Starting capacitor (80µF 220V, 6.3mm)117U50151
4Cord relief103N10101
5Cover103N20111
6Bolt joint for one compressor | M6 | ø16mm118-19171

Compressor Overview

General

Code number105H6856
ApprovalsEN 60335-2-34 w. Annex AA, CCC
Compressors on pallet80

Application

ApplicationLBP/MBP
Frequency50 Hz / 60 Hz
Evaporating temperature-40 to 5 °C
Voltage range198 - 254 V
Max. condensing temperature continuous (short)55 (65) °C
Max. winding temperature continuous (short)125 (135) °C

Cooling Requirements

Frequency50 Hz60 Hz
ApplicationLBPMBPHBPLBPMBPHBP
32°CF1F1-F1F1-
38°CF1F1-F1F1-
43°CF2F2-F2F2-

Cooling Legend: S = Static cooling normally sufficient, O = Oil cooling, F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature), F2 = Fan cooling 3.0 m/s necessary, SG = Suction gas cooling normally sufficient, - = not applicable in this area.

Remarks on application: Run capacitor 4 µF compulsory in 43°C ambient temperature at MBP conditions.

Motor Specifications

Motor typeRSIR/RSCR/CSIR
LRA (rated after 4 sec. UL984), HST | LST10.4 A | 9.2 A
Cut in Current, HST | LST10.4 A | 13.6 A
Resistance, main | start winding (25°C)8.2 Ω | 14.7 Ω

Design and Dimensions

Displacement8.35 cm³
Oil quantity (type)270 (polyolester) cm³
Maximum refrigerant charge150 g
Free gas volume in compressor2360 cm³
Weight without electrical equipment10.5 kg

Dimensions

mm
Height (A)203
Height (B)197

Diagrams illustrating the physical dimensions of the NL9CN compressor, showing height (A) and depth (B). Also shows the layout and angles of the suction, process, and discharge connectors.

Connector Details

location/I.D. mm | anglematerial | comment
Suction connector8.2 | 15° CCopper | Rubber plug
Process connector6.2 | 25° DCopper | Rubber plug
Discharge connector6.2 | 35° ECopper | Rubber plug
Oil cooler connector- | -- | -

Connector tolerance: ±0.09 mm I.D.

Performance Data

EN 12900 Household (CECOMAF) - 220V, 50Hz, 2 W PTC consumption incl., fan cooling F₁

Evap. temp. in °C-45-40-35-30-25-23.3-20-15-10-6.7-5057.2101520
Capacity in W1381942593353644235266437307789301102
Power cons. in W169196223250259278306334354364395428
Current cons. in A1.441.501.561.641.671.731.831.952.032.082.212.36
COP in W/W0.810.991.161.341.401.531.721.922.062.132.352.58

ASHRAE LBP - 220V, 50Hz, 2 W PTC consumption incl., fan cooling F₁

Evap. temp. in °C-45-40-35-30-25-23.3-20-15-10-6.7-5057.2101520
Capacity in W15321628937440647358771981686910411235
Power cons. in W169196223250259278306334354364395428
Current cons. in A1.441.501.561.641.671.731.831.952.032.082.212.36
COP in W/W0.911.101.291.491.561.701.922.152.302.392.632.89

Accessories and Mounting

Accessories for NL9CN

FigureCode numberTest conditionsEN 12900/ CECOMAFASHRAE LBP
a1103N0011Condensing temperature45°C45°C
(pos.1)103N0018Ambient temperature32°C32°C
a1103N0016Suction gas temperature32°C32°C
(pos.2)103N0021Liquid temperatureno subcooling32°C
a2117U7002---
c117U5015---
b103N2010---
d103N1010---
e117-7117---
(optional)117-7119---
g103N0476---

Mounting Accessories

DescriptionSizeCode number
Bolt joint for one comp.Ø: 16 mm118-1917
Bolt joint in quantitiesØ: 16 mm118-1918
Snap-on in quantitiesØ: 16 mm118-1919

Wiring Diagrams

Diagrams illustrate typical wiring configurations for RSIR, RSCR, and CSIR motor types. Each diagram shows the main winding, start winding, and winding protector components, labeled with electrical symbols like N (Neutral), S (Start), C (Capacitor), and L (Line). Warning symbols for refrigerants R600a and R290 are also depicted.

Service and Safety Information

Refrigerant Safety Warnings

Warning symbols indicate flammability hazards for refrigerants R600a and R290 [?].

Brazing on Suction Connectors

An illustration shows the process of brazing on suction connectors, with a warning about maximum temperature (150°C/302°F) at the socket [❗]. The recommended brazing solder is phosphor (LP7) or silver. A checkmark [✔️] indicates a correct procedure, while a crossed-out pipe [❌] might indicate an incorrect one.

Refer to Product Bulletin: Brazing on Suction Connectors (Compressors with Direct Suction Intake).

PDF preview unavailable. Download the PDF instead.

single-pack-195B4540 GPL Ghostscript 10.05.1 Adobe InDesign 17.4 (Windows)

Related Documents

PreviewSecop NL9CN Compressor: Technical Specifications, Data, and Accessories
Detailed technical specifications, performance data, component list, and accessory information for the Secop NL9CN LBP/MBP Compressor (R290, 220-240V 50Hz CSIR).
PreviewSecop NL9CN Compressor: Technical Specifications and Parts List
Detailed technical specifications, cooling requirements, motor data, dimensions, and parts list for the Secop NL9CN LBP/MBP Compressor (220-240V 50Hz RSCR). Includes performance data, accessory information, and service notes.
PreviewSECOP KLF4.8CND Compressor Technical Data Sheet
Detailed technical specifications for the SECOP KLF4.8CND compressor, including electrical data, performance tables, operating ranges, and configuration details for CSIR and RSCR motor types. Suitable for R290 refrigerant.
PreviewSecop NLE8.0CN Compressor Technical Datasheet - 115V/60Hz
Comprehensive technical datasheet for the Secop NLE8.0CN compressor, covering single pack details, compressor design specifications, various configurations (CSIR, RSIR, RSCR), electrical data, dimensions, performance tables, operating pressure ranges, wiring diagrams, and service information for 115V/60Hz operation.
PreviewSecop PL35G Universal Compressor R134a Datasheet and Specifications
Detailed technical specifications, performance data, accessories, and dimensions for the Secop PL35G Universal Compressor (R134a, 220-240V 50/60Hz CSIR). Includes EN 12900 and ASHRAE LBP performance tables.
PreviewSECOP KLF4.8CND Compressor Technical Data Sheet
Detailed technical specifications, performance data, dimensions, and configuration options for the SECOP KLF4.8CND R290 compressor, designed for 220-240V/50Hz operation.
PreviewSecop PLE35K Energy-Optimized Compressor R600a - Technical Specifications
Detailed technical specifications and performance data for the Secop PLE35K energy-optimized compressor, R600a refrigerant, 220-240V, 50Hz, RSCR type. Includes performance tables, dimensions, and accessory information.
PreviewSecop SC12CNX.2 Compressor Technical Data and Specifications
Comprehensive technical specifications, performance data, dimensions, operating limits, and wiring diagrams for the Secop SC12CNX.2 compressor. This datasheet covers its use with R290 refrigerant for 220-240V/50Hz applications.