6ES7416-3XS07-0AB0
Data sheet 6ES7416-3XS07-0AB0
200225-simatic-s7-400 Data sheet
6ES7416-3XS07-0AB0
SIMATIC S7-400, CPU 416-3, Central processing unit with: Work memory 16 MB, (8 MB code, 8 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP, 3rd interface plug-in IFM module
General information Product type designation HW functional status Firmware version Product function Isochronous mode Engineering with Programming package
CiR - Configuration in RUN CiR synchronization time, basic load CiR synchronization time, time per I/O byte
Supply voltage Rated value (DC)
Input current from backplane bus 5 V DC, typ. from backplane bus 5 V DC, max. from backplane bus 24 V DC, max. from interface 5 V DC, max.
Power loss Power loss, typ. Power loss, max.
Memory Type of memory Work memory integrated integrated (for program) integrated (for data) expandable Load memory expandable FEPROM expandable FEPROM, max. integrated RAM, max. expandable RAM expandable RAM, max. Backup present with battery without battery
Battery
6ES74163XS070AB0 Page 1/10
CPU 416-3 01 V7.0
Yes; For PROFIBUS only
STEP 7 V5.4 or higher with HSP 261
100 ms 10 µs
Power supply via system power supply
1.1 A 1.3 A 450 mA; 150 mA per DP interface 90 mA; At each DP interface
5.5 W 6.5 W
RAM
16 Mbyte 8 Mbyte 8 Mbyte No
Yes; with Memory Card (FLASH) 64 Mbyte 1 Mbyte Yes; with Memory Card (RAM) 64 Mbyte
Yes Yes; all data No
11/21/2021
Subject to change without notice © Copyright Siemens
Backup battery Backup current, typ. Backup current, max. Backup time, max.
Feeding of external backup voltage to CPU CPU processing times
for bit operations, typ. for word operations, typ. for fixed point arithmetic, typ. for floating point arithmetic, typ. CPU-blocks DB
Number, max. Size, max. FB Number, max. Size, max. FC Number, max. Size, max. OB Number, max. Size, max. Number of free cycle OBs Number of time alarm OBs Number of delay alarm OBs Number of cyclic interrupt OBs Number of process alarm OBs Number of DPV1 alarm OBs Number of isochronous mode OBs Number of multicomputing OBs Number of background OBs Number of startup OBs Number of asynchronous error OBs Number of synchronous error OBs Nesting depth per priority class additional within an error OB Counters, timers and their retentivity S7 counter Number Retentivity
-- adjustable -- lower limit -- upper limit -- preset Counting range -- lower limit -- upper limit IEC counter present Type Number S7 times Number Retentivity -- adjustable -- lower limit -- upper limit
6ES74163XS070AB0 Page 2/10
180 µA; up to 40 °C 850 µA Dealt with in the module data manual with the secondary conditions and the factors of influence 5 V DC to 15 V DC
12.5 ns 12.5 ns 12.5 ns 25 ns
10 000; Number range: 1 to 16000 64 kbyte
5 000; Number range: 0 to 7999 64 kbyte
5 000; Number range: 0 to 7999 64 kbyte
see instruction list 64 kbyte 1; OB 1 8; OB 10-17 4; OB 20-23 9; OB 30-38 (shortest cycle that can be set = 500 µs) 8; OB 40-47 3; OB 55-57 4; OB 61-64 1; OB 60 1; OB 90 3; OB 100-102 9; OB 80-88 2; OB 121, 122
24 2
2 048
Yes 0 2 047 Z 0 to Z 7
0 999
Yes SFB Unlimited (limited only by RAM capacity)
2 048
Yes 0 2 047
11/21/2021
Subject to change without notice © Copyright Siemens
-- preset Time range
-- lower limit -- upper limit IEC timer present Type Number Data areas and their retentivity Retentive data area (incl. timers, counters, flags), max. Flag Size, max. Retentivity available Retentivity preset Number of clock memories Local data adjustable, max. preset Address area I/O address area Inputs Outputs Process image Inputs, adjustable Outputs, adjustable Inputs, default Outputs, default consistent data, max. Access to consistent data in process image Subprocess images Number of subprocess images, max. Digital channels Inputs -- of which central Outputs -- of which central Analog channels Inputs -- of which central Outputs -- of which central Hardware configuration Number of expansion units, max. connectable OPs Multicomputing Interface modules Number of connectable IMs (total), max. Number of connectable IM 460s, max. Number of connectable IM 463s, max. Number of DP masters integrated via CP via IM 467 Mixed mode IM + CP permitted
via interface module Number of pluggable S5 modules (via adapter capsule in central device), max. Number of IO Controllers integrated
6ES74163XS070AB0 Page 3/10
No times retentive
10 ms 9 990 s
Yes SFB Unlimited (limited only by RAM capacity)
Total working and load memory (with backup battery)
16 kbyte; Size of bit memory address area Yes MB 0 to MB 15 8; in 1 memory byte
32 kbyte 16 kbyte
16 kbyte 16 kbyte
16 kbyte 16 kbyte 512 byte 512 byte 244 byte Yes
15
131 072 131 072 131 072 131 072
8 192 8 192 8 192 8 192
21 95 Yes; 4 CPUs max. (with UR1 or UR2)
6 6 4; IM 463-2
2 10; CP 443-5 Extended 4 No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode 1 6
0 11/21/2021
Subject to change without notice © Copyright Siemens
via CP
Number of operable FMs and CPs (recommended) FM CP, PtP
PROFIBUS and Ethernet CPs
Slots required slots
Time of day Clock Hardware clock (real-time) retentive and synchronizable Resolution Deviation per day (buffered), max. Deviation per day (unbuffered), max. Operating hours counter Number Number/Number range Range of values Granularity retentive Clock synchronization supported to MPI, master to MPI, slave to DP, master to DP, slave in AS, master in AS, slave on Ethernet via NTP to IF 964 DP Time difference in system when synchronizing via MPI, max.
Interfaces Interfaces/bus type
Number of RS 485 interfaces Number of other interfaces
1. Interface Interface type Isolated Interface types RS 485 Output current of the interface, max. Protocols MPI PROFIBUS DP master PROFIBUS DP slave MPI Number of connections
Transmission rate, max. Services
-- PG/OP communication -- Routing -- Global data communication -- S7 basic communication
6ES74163XS070AB0 Page 4/10
4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode
Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: limited by number of connections 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller
2
Yes Yes 1 ms 1.7 s; Power off 8.6 s; For power On
16 0 to 15 SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours 1 h Yes
Yes Yes Yes Yes Yes Yes Yes No; Via CP Yes
200 ms
1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable) 2; Combined MPI / PROFIBUS DP and PROFIBUS DP 1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES79642AA04-0AB0)
MPI/PROFIBUS DP Yes
Yes 150 mA
Yes Yes Yes
44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 12 Mbit/s
Yes Yes Yes Yes
11/21/2021
Subject to change without notice © Copyright Siemens
-- S7 communication -- S7 communication, as client -- S7 communication, as server PROFIBUS DP master Number of connections, max.
Transmission rate, max. Number of DP slaves, max. Services
-- PG/OP communication -- Routing -- Global data communication -- S7 basic communication -- S7 communication -- S7 communication, as client -- S7 communication, as server -- Equidistance -- Isochronous mode -- SYNC/FREEZE -- Activation/deactivation of DP slaves -- Direct data exchange (slave-to-slave communication) -- DPV1 Address area -- Inputs, max. -- Outputs, max. User data per DP slave -- User data per DP slave, max. -- Inputs, max. -- Outputs, max. -- Slots, max. -- per slot, max. PROFIBUS DP slave Number of connections GSD file Transmission rate, max. automatic baud rate search Address area, max. User data per address area, max. -- of which consistent, max. Services -- PG/OP communication -- Routing -- Global data communication -- S7 basic communication -- S7 communication -- S7 communication, as client -- S7 communication, as server -- Direct data exchange (slave-to-slave communication) -- DPV1 Transfer memory -- Inputs -- Outputs 2. Interface Interface type Isolated Number of connection resources Interface types RS 485 Output current of the interface, max.
6ES74163XS070AB0 Page 5/10
Yes Yes Yes
32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
12 Mbit/s
32
Yes Yes; S7 routing No Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes
2 kbyte 2 kbyte
244 byte 244 byte 244 byte 244 128 byte
32 http://support.automation.siemens.com/WW/view/en/113652 12 Mbit/s No 32; Virtual slots 32 byte 32 byte
Yes; with interface active Yes; with interface active No No Yes Yes Yes No
No
244 byte 244 byte
PROFIBUS DP Yes 32
Yes 150 mA
11/21/2021
Subject to change without notice © Copyright Siemens
Protocols PROFIBUS DP master PROFIBUS DP slave
PROFIBUS DP master Number of connections, max. Transmission rate, max. Number of DP slaves, max. Services -- PG/OP communication -- Routing -- Global data communication -- S7 basic communication -- S7 communication -- S7 communication, as client -- S7 communication, as server -- Equidistance -- Isochronous mode -- SYNC/FREEZE -- Activation/deactivation of DP slaves -- Direct data exchange (slave-to-slave communication) -- DPV1 Address area -- Inputs, max. -- Outputs, max. User data per DP slave -- User data per DP slave, max. -- Inputs, max. -- Outputs, max. -- Slots, max. -- per slot, max.
PROFIBUS DP slave Number of connections GSD file Transmission rate, max. Address area, max. User data per address area, max. -- of which consistent, max. Services -- Routing Transfer memory -- Inputs -- Outputs
3. Interface Interface type Plug-in interface modules Isolated automatic detection of transmission rate Number of connection resources Interface types RS 485 Output current of the interface, max. Protocols MPI PROFIBUS DP master PROFIBUS DP slave PROFIBUS DP master Number of connections, max. Transmission rate, max. Number of DP slaves, max.
6ES74163XS070AB0 Page 6/10
Yes Yes
32 12 Mbit/s 125
Yes Yes; S7 routing No Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes
8 kbyte 8 kbyte
244 byte 244 byte 244 byte 244 128 byte
32 http://support.automation.siemens.com/WW/view/en/113652 12 Mbit/s 32 32 byte 32 byte
Yes; with interface active
244 byte 244 byte
pluggable interface module (IF), technical data as for 2nd interface IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) Yes No 32
Yes 150 mA
No Yes Yes
32 12 Mbit/s 125
11/21/2021
Subject to change without notice © Copyright Siemens
Services -- PG/OP communication -- Routing -- Global data communication -- S7 basic communication -- S7 communication -- S7 communication, as client -- S7 communication, as server -- Equidistance -- Isochronous mode -- SYNC/FREEZE -- Activation/deactivation of DP slaves -- Direct data exchange (slave-to-slave communication) -- DPV0 -- DPV1
Address area -- Inputs, max. -- Outputs, max.
User data per DP slave -- User data per DP slave, max. -- Inputs, max. -- Outputs, max. -- Slots, max. -- per slot, max.
PROFIBUS DP slave Number of connections GSD file Transmission rate, max. automatic baud rate search Address area, max. User data per address area, max. -- of which consistent, max. Services -- PG/OP communication -- Routing -- Global data communication -- S7 basic communication -- S7 communication -- S7 communication, as client -- S7 communication, as server -- Direct data exchange (slave-to-slave communication) -- DPV1 Transfer memory -- Inputs -- Outputs
Protocols SIMATIC communication S7 routing Open IE communication ISO-on-TCP (RFC1006) -- Data length, max. Web server supported
Isochronous mode Equidistance Number of DP masters with isochronous mode User data per isochronous slave, max. shortest clock pulse
6ES74163XS070AB0 Page 7/10
Yes Yes; S7 routing No Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes Yes
8 kbyte 8 kbyte
244 byte 244 byte 244 byte 244 128 byte
32 http://support.automation.siemens.com/WW/view/en/113652 12 Mbit/s No 32 32 byte 32 byte
Yes Yes; with interface active No No Yes Yes Yes No
No
244 byte 244 byte
Yes
Via CP 443-1 and loadable FB 1 452 bytes via CP 443-1 Adv.
No
Yes 3 244 byte 1 ms; 0.5 ms without use of SFC 126, 127
11/21/2021
Subject to change without notice © Copyright Siemens
max. cycle communication functions / header
PG/OP communication Number of connectable OPs without message processing Number of connectable OPs with message processing
Data record routing Global data communication
supported Number of GD loops, max. Number of GD packets, transmitter, max. Number of GD packets, receiver, max. Size of GD packets, max. Size of GD packet (of which consistent), max. S7 basic communication supported User data per job, max. User data per job (of which consistent), max. S7 communication supported as server as client User data per job, max. User data per job (of which consistent), max. S5 compatible communication supported User data per job, max. User data per job (of which consistent), max. Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. Standard communication (FMS) supported Number of connections overall usable for PG communication
-- reserved for PG communication -- adjustable for PG communication, max. usable for OP communication -- reserved for OP communication -- adjustable for OP communication, max. usable for S7 basic communication -- reserved for S7 basic communication -- adjustable for S7 basic communication, max. usable for S7 communication -- reserved for S7 communication -- adjustable for S7 communication, max. usable for routing -- reserved for routing -- adjustable for routing, max. S7 message functions Number of login stations for message functions, max.
Symbol-related messages SCAN procedure Program alarms Process diagnostic messages simultaneously active Alarm-S blocks, max. Alarm 8-blocks
Number of instances for alarm 8 and S7 communication blocks, max.
32 ms
Yes 95
95; When using Alarm_S/SQ and Alarm_D/DQ
Yes
Yes 16 16 32 54 byte 1 variable
Yes 76 byte 1 variable
Yes Yes Yes 64 kbyte 462 byte; 1 variable
Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 kbyte 240 byte 64/64
Yes; Via CP and loadable FB
96 95 1 0 95 1 0 94 0 0 94 0 0 47 0 0
95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) Yes Yes Yes Yes 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks Yes 4 000
6ES74163XS070AB0 Page 8/10
11/21/2021
Subject to change without notice © Copyright Siemens
preset, max. Process control messages Number of archives that can log on simultaneously (SFB 37 AR_SEND) Number of messages
overall, max. in 100 ms grid, max. in 500 ms grid, max. in 1000 ms grid, max. Number of additional values with 100 ms grid, max. with 500, 1000 ms grid, max. Test commissioning functions Status block Single step Number of breakpoints Status/control Status/control variable Variables Number of variables, max. Forcing Forcing Forcing, variables Number of variables, max. Diagnostic buffer present Number of entries, max.
-- adjustable -- preset Service data can be read out Standards, approvals, certificates CE mark CSA approval UL approval cULus FM approval RCM (formerly C-TICK) KC approval EAC (formerly Gost-R) Use in hazardous areas ATEX Ambient conditions Ambient temperature during operation min. max. configuration / header Configuration software STEP 7 configuration / programming / header Command set Nesting levels Access to consistent data in process image System functions (SFC) System function blocks (SFB) Programming language -- LAD -- FBD -- STL -- SCL
6ES74163XS070AB0 Page 9/10
600 Yes 32
1 024 128 512 1 024
1 10
Yes; Up to 16 simultaneously Yes 16
Yes; Up to 16 variable tables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 70; Status/control
Yes Inputs, outputs, bit memories, peripheral inputs, peripheral outputs 512
Yes 3 200 Yes 120
Yes
Yes Yes Yes Yes Yes Yes Yes Yes
ATEX II 3G Ex nA IIC T4 Gc
0 °C 60 °C
Yes
see instruction list 7 Yes see instruction list see instruction list
Yes Yes Yes Yes
11/21/2021
Subject to change without notice © Copyright Siemens
-- CFC
Yes
-- GRAPH
Yes
-- HiGraph®
Yes
configuration / programming / number of simultaneously active SFC / header
-- DPSYC_FR
2; SFC 11; per interface
-- D_ACT_DP
8; SFC 12; per interface
-- RD_REC
8; SFC 59; per interface
-- WR_REC
8; SFC 58; per interface
-- WR_PARM
8; SFC 55; per interface
-- PARM_MOD
1; SFC 57; per interface
-- WR_DPARM
2; SFC 56; per interface
-- DPNRM_DG
8; SFC 13; per interface
-- RDSYSST
8; SFC 51
-- DP_TOPOL
1; SFC 103; per interface
configuration / programming / number of simultaneously active SFB / header
-- RDREC
8; SFB 52; per interface, but not more than 32 across all external interfaces
-- WRREC
8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection
User program protection/password protection
Yes
Block encryption
Yes; With S7 block Privacy
Dimensions
Width
50 mm
Height
290 mm
Depth
219 mm
Weights
Weight, approx.
900 g
last modified:
8/10/2021
6ES74163XS070AB0 Page 10/10