Realme Chongqing Mobile Telecommunications Corp., Ltd. RMX3951 2AUYFRMX3951 2AUYFRMX3951 rmx3951
Report No.: BL-SZ2460066-601 TEST REPORT Applicant: Address: Equipment Type: Model Name: Brand Name: FCC ID: Test Standard: Sample Arrival Date: Test Date: Date of Issue: Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China Mobile Phone RMX3951 realme 2AUYFRMX3951 47 CFR Part 15 Subpart C (refer to section 3.1) Jun. 03, 2024 Jun. 04, 2024 - Jun. 19, 2024 Jul. 04, 2024 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Si Xiao Checked by: Ye Hongji Approved by: Liao Jianming (Technical Director) _______________ _______________ _______________ Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 1 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 Version Rev. 01 Revision History Issue Date Jul. 04, 2024 Revisions Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION........................................................................................................ 4 1.1 Test Laboratory ............................................................................................................ 4 1.2 Test Location ................................................................................................................ 4 2 PRODUCT INFORMATION ....................................................................................................... 5 2.1 Applicant Information .................................................................................................... 5 2.2 Manufacturer Information.............................................................................................. 5 2.3 General Description for Equipment under Test (EUT) ................................................... 5 2.4 Technical Information ................................................................................................... 6 3 SUMMARY OF TEST RESULTS ............................................................................................... 9 3.1 Test Standards ............................................................................................................. 9 3.2 Test Verdict ................................................................................................................ 10 4 GENERAL TEST CONFIGURATIONS .................................................................................... 11 4.1 Test Environments...................................................................................................... 11 4.2 Test Equipment List .................................................................................................... 11 4.3 Test Software List ....................................................................................................... 11 4.4 Measurement Uncertainty........................................................................................... 12 4.5 Description of Test Setup ........................................................................................... 12 4.6 Measurement Results Explanation Example............................................................... 15 5 TEST ITEMS ........................................................................................................................... 16 5.1 Antenna Requirements ............................................................................................... 16 5.2 Frequency Hopping Systems...................................................................................... 17 5.3 Number of Hopping Frequencies ................................................................................ 19 5.4 Peak Output Power .................................................................................................... 20 5.5 Occupied Bandwidth................................................................................................... 21 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 2 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.6 Carrier Frequency Separation..................................................................................... 22 5.7 Time of Occupancy (Dwell time) ................................................................................. 23 5.8 Conducted Spurious Emission & Authorized-band band-edge.................................... 25 5.9 Conducted Emission................................................................................................... 26 5.10 Radiated Spurious Emission ....................................................................................... 27 5.11 Band Edge (Restricted-band band-edge).................................................................... 29 ANNEX A TEST RESULT ........................................................................................................... 30 A.1 Number of Hopping Frequency ................................................................................... 30 A.2 Peak Output Power .................................................................................................... 31 A.3 20 dB and 99% bandwidth .......................................................................................... 34 A.4 Hopping Frequency Separation .................................................................................. 39 A.5 Average Time of Occupancy....................................................................................... 40 A.6 Conducted Spurious Emissions & Authorized-band band-edge .................................. 43 A.7 Conducted Emissions ................................................................................................. 50 A.8 Radiated Spurious Emission ....................................................................................... 52 A.9 Band Edge (Restricted-band band-edge).................................................................... 66 ANNEX B TEST SETUP PHOTOS ............................................................................................. 70 ANNEX C EUT EXTERNAL PHOTOS......................................................................................... 70 ANNEX D EUT INTERNAL PHOTOS.......................................................................................... 70 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 3 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 1 GENERAL INFORMATION 1.1 Test Laboratory Name Address Phone Number Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China +86 755 6685 0100 1.2 Test Location Name Location Accreditation Certificate Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China The laboratory is a testing organization accredited by FCC as a accredited testing laboratory. The designation number is CN1196. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 4 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Address Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China 2.2 Manufacturer Information Manufacturer Address Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China 2.3 General Description for Equipment under Test (EUT) EUT Name Model Name Under Test Series Model Name Description of Model name differentiation Hardware Version Software Version Dimensions (Approx.) Weight (Approx.) EUT ID IMEI Number Mobile Phone RMX3951 N/A N/A 11 realme UI 5.0 about 165.6×76.1×7.79(mm) about 190g S31, S38, S41 S31: IMEI1: 862456070025433 IMEI2:862456070025425 S38: IMEI1: 862456070034278 IMEI2:862456070034260 S41: IMEI1: 862456070024279 IMEI2:862456070024261 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 5 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 2.4 Technical Information 2G Network GSM/GPRS/EDGE 850/1900 MHz 3G Network WCDMA/HSDPA/HSUPA/HSPA+ Band 2/4/5 4G Network LTE FDD Band 2/4/5/7/12/13/17/26/66 LTE TDD Band 38/41 LTE CA Uplink (UL): CA_7C, CA_38C, CA_41C LTE Downlink (DL): CA_2C, CA_7B, CA_7C, CA_38C, CA_41C, CA_41A-41A, CA_7A-7A, CA_2A-38A, CA_5A-41A, CA_5A-66A, CA_7A-66A, CA_2A-2A, CA_2A-5A, CA_2A-7A, CA_2A-12A, CA_4A-5A, CA_4A-7A, CA_5A-7A, CA_12A-66A, CA_66A-66A, CA_4A-4A, CA_26A-41A, CA_5A-38A, CA_2A-4A, CA_38A-66A, CA_26A-38A, CA_2A-66A, CA_7A-26A 5G Network Network and Wireless connectivity SA: NR n5/n7/n38/n41/n66 NSA UL (EN-DC): DC_7A_n5A, DC_66A_n5A, DC_2A_n7A, DC_4A_n7A, DC_5A_n7A, DC_7A_n7A, DC_66A_n7A, DC_2A_n66A, DC_5A_n66A, DC_7A_n66A, DC_66A_n66A, DC_2A_n38A, DC_4A_n38A, DC_5A_n38A, DC_38A_n38A, DC_66A_n38A, DC_2A_n41A, DC_4A_n41A, DC_26A_n41A, DC_41A_n41A, DC_66A_n41A DL(EN-DC): DC_7C_n5A, DC_7C_n66A, DC_5A-66A_n66A, DC_7A-66A_n66A, DC_2A-5A_n66A, DC_5A-7A_n7A, DC_5A- 7A_n66A, DC_66A-66A_n5A, DC_66A-66A_n7A NR CA Downlink (DL): CA_n5A-n7A, CA_n7B Bluetooth (BR+EDR+BLE) 2.4G WIFI 802.11b, 802.11g, 802.11n(HT20/40) and VHT(20/40) 5G WIFI 802.11a, 802.11n(HT20/40) and 802.11ac(VHT20/40/80) U-NII-1/2A/2C/3, GPS, GLONASS, BDS, Galileo, NFC The requirement for the following technical information of the EUT was tested in this report: Modulation Technology FHSS Modulation Type GFSK, /4-DQPSK, 8-DPSK Mobile Product Type Portable Fix Location Transfer Rate DH5: 1 Mbps 2DH5: 2 Mbps 3DH5: 3 Mbps Frequency Range The frequency range used is 2400 MHz to 2483.5 MHz. Number of Channel 79 (at intervals of 1 MHz) Tested Channel 0 (2402 MHz), 39 (2441 MHz), 78 (2480 MHz) Antenna Type IFA Antenna Antenna Gain -0.3 dBi Antenna Impedance 50 Antenna System (MIMO N/A Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 6 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 Smart Antenna) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 7 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 All channel was listed on the following table: Channel Freq. Channel Freq. number (MHz) number (MHz) 0 2402 21 2423 1 2403 22 2424 2 2404 23 2425 3 2405 24 2426 4 2406 25 2427 5 2407 26 2428 6 2408 27 2429 7 2409 28 2430 8 2410 29 2431 9 2411 30 2432 10 2412 31 2433 11 2413 32 2434 12 2414 33 2435 13 2415 34 2436 14 2416 35 2437 15 2417 36 2438 16 2418 37 2439 17 2419 38 2440 18 2420 39 2441 19 2421 40 2442 20 2422 41 2443 Channel number 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Freq. (MHz) 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 Channel number 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 - Freq. (MHz) 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 - Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 8 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 3 SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 47 CFR Part 15, Subpart C Intentional radiators of radio frequency equipment 2 ANSI C63.10-2013 American National Standard for Testing Unlicensed Wireless Devices Guidance for compliance measurements on digital transmission KDB 558074 D01 15.247 3 system, frequency hopping spread spectrum system, and hybrid Meas Guidance v05r02 system devices operating under section 15.247 of the FCC rules Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 9 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 3.2 Test Verdict No. Description FCC Part No. Channel Test Result Verdict Remark 1 Antenna Requirement 15.203 N/A -- Pass Note 1 Number of Hopping 2 Frequencies 15.247(a) Hopping Mode ANNEX A.1 Pass Note 2 Low/Middle/Hig 3 Peak Output Power 15.247(b) ANNEX A.2 Pass -- h Low/Middle/Hig 4 Occupied Bandwidth 15.247(a) ANNEX A.3 Pass -- h Carrier Frequency 5 Separation 15.247(a) Hopping Mode ANNEX A.4 Pass Note 2 Time of Occupancy 6 (Dwell time) 15.247(a) Hopping Mode ANNEX A.5 Pass Note 2 Conducted Spurious Hopping Mode; Emission & 7 15.247(d) Low/Middle/Hig ANNEX A.6 Authorized-band band- h edge Pass Note 2 8 Conducted Emission 15.207 Low/Middle/Hig ANNEX A.7 h Pass Note 2 Radiated Spurious 9 Emission 15.209 15.247(d) Low/Middle/Hig ANNEX A.8 h Pass Note 2 Band Edge(Restricted- 15.209 10 band band-edge) 15.247(d) Low/High ANNEX A.9 Pass Note 2 Note 1: The EUT has a permanently and irreplaceable attached antenna, which complies with the requirement FCC 15.203. Note 2: /4-DQPSK is the EDR 2M rate mode, 8-DPSK is the EDR 3M rate mode. The consistency of test results in /4-DQPSK and 8-DPSK is very high. So we chose 8-DPSK as a typical representative to appear on the report. Another we will show all the modes on the RF output power test item. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 10 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 4 GENERAL TEST CONFIGURATIONS 4.1 Test Environments During the measurement, the normal environmental conditions were within the listed ranges: Relative Humidity Atmospheric Pressure Temperature Working Voltage of the EUT 50% to 70% 100 kPa to 102 kPa NT (Normal Temperature) NV (Normal Voltage) +21.2 to +25.0 3.89 V 4.2 Test Equipment List Description Spectrum Analyzer Spectrum Analyzer Test Antenna-Horn Test Antenna-Horn Anechoic Chamber Amplifier Manufacturer KEYSIGHT KEYSIGHT SCHWARZBECK A-INFO RAINFORD COM-MV Amplifier COM-MV EMI Receiver Test Antenna-Bi-Log Test Antenna-Loop Amplifier Anechoic Chamber EMI Receiver Test Antenna-Bi-Log Amplifier Anechoic Chamber EMI Receiver LISN Shielded Enclosure ROHDE&SCHWARZ SCHWARZBECK SCHWARZBECK COM-MV EMC Electronic Co., Ltd KEYSIGHT SCHWARZBECK COM-MV RAINFORD KEYSIGHT SCHWARZBECK YiHeng Electronic Co., Ltd Model N9020A N9020A BBHA 9120D LB-180400KF 9m*6m*6m LSCX_LNA112G-01 XKu_LNA718G-01 ESRP VULB 9168 FMZB 1519 ZT30-1000M 20.10*11.60*7. 35m N9038A VULB 9163 ZT30-1000M 9m*6m*6m N9010B NSLK 8127 3.5m*3.1m*2.8 m Serial No. MY46471071 MY52510065 01631 J211060273 144 180602 180601 101036 9168-01162 1519-037 B2018054558 130 MY53220118 9163-624 B2017119082 101 MY57110309 8127-687 112 Cal. Date 2023.07.25 2023.09.05 2022.02.23 2021.07.02 2022.02.19 2023.09.05 2023.09.05 2023.09.05 2023.08.04 2024.01.23 2023.12.05 2021.08.15 2023.09.05 2021.08.20 2023.12.05 2023.03.04 2023.09.05 2024.05.08 2022.02.19 Cal. Due 2024.07.24 2024.09.04 2025.02.22 2024.07.01 2024.09.03 2024.09.04 2024.09.04 2024.09.04 2024.08.03 2025.01.22 2024.12.04 2024.08.14 2024.09.04 2024.08.19 2024.12.04 2026.03.03 2024.09.04 2025.05.07 2025.02.18 4.3 Test Software List Description BL410R BL410E Manufacturer BALUN BALUN Software Version V2.1.1.488 V22.930 Serial No. N/A N/A Applicable test Setup The section 4.5.1 The section 4.5.2&4.5.3&4.5.4&4.5.5 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 11 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 4.4 Measurement Uncertainty The following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Parameters Uncertainty Occupied Channel Bandwidth 2.8% RF output power, conducted 1.28 dB Power Spectral Density, conducted 1.30 dB Unwanted Emissions, conducted 1.84 dB All emissions, radiated 5.36 dB Temperature 0.8°C Humidity 4% 4.5 Description of Test Setup 4.5.1 For Antenna Port Test Conducted value (dBm) = Measurement value (dBm) + cable loss (dB) For example: the measurement value is 10 dBm and the cable 0.5dBm used, then the final result of EUT: Conducted value (dBm) = 10 dBm + 0.5 dB = 10.5 dBm (Diagram 1) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 12 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 4.5.2 For AC Power Supply Port Test (Diagram 2) 4.5.3 For Radiated Test (Below 30 MHz) (Diagram 3) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 13 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 4.5.4For Radiated Test (30 MHz-1 GHz) (Diagram 4) 4.5.5 For Radiated Test (Above 1 GHz) (Diagram 5) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 14 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 4.6 Measurement Results Explanation Example 4.6.1 For conducted test items: The offset level is set in the spectrum analyzer to compensate the RF cable loss and attenuator between EUT conducted output port and spectrum analyzer. With the offset compensation, the spectrum analyzer reading level is exactly the EUT RF output level. The spectrum analyzer offset is derived from RF cable loss and attenuator factor. Offset = RF cable loss + attenuator factor. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 15 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5 TEST ITEMS 5.1 Antenna Requirements 5.1.1 Relevant Standards FCC §15.203 & 15.247(b) An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of § 15.211, § 15.213, § 15.217, § 15.219, or § 15.221. Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with § 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this part are not exceeded. If directional gain of transmitting antennas is greater than 6 dBi, the power shall be reduced by the same level in dB comparing to gain minus 6 dBi. For the fixed point-to-point operation, the power shall be reduced by one dB for every 3 dB that the directional gain of the antenna exceeds 6 dBi. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the FCC rule. 5.1.2 Antenna Anti-Replacement Construction The Antenna Anti-Replacement as following method: Protected Method Description The antenna is embedded in the An embedded-in antenna design is used. product. Reference Documents Photo Item Please refer to the EUT Photo documents. 5.1.3 Antenna Gain The antenna peak gain of EUT is less than 6 dBi. Therefore, it is not necessary to reduce maximum peak output power limit. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 16 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.2 Frequency Hopping Systems 5.2.1 Relevant Standards FCC §15.247(a) (1) (i) (ii) (iii) (iv); FCC §15.247(g); FCC §15.247(h) Describe how the hopping sequence is generated. Provide an example of the hopping sequence channels, to demonstrate that the sequence meets the requirement specified in the definition of an FHSS system. Per the definition in Section 2.1(c), the hop set shall appear as random in the near term, shall appear as evenly distributed in the long term, and sequential hops shall be randomly distributed in both direction and magnitude of change. Describe how each individual EUT meets the requirement that each of its hopping channels is used equally on average (e.g., that each new transmission event begins on the next channel in the hopping sequence after the final channel used in the previous transmission event). Describe how the associated receiver(s) complies with the requirement that the input bandwidth (either RF or IF) matches the bandwidth of the transmitted signal. Describe how the associated receiver(s) has the ability to shift frequencies in synchronization with the transmitted signals. For short burst systems, describe how the EUT complies with the requirement that it be designed to be capable of operating as a true frequency hopping system. Specifically, the device shall comply with the equal frequency use and pseudorandom hopping sequence requirement when transmitting in short bursts, and shall be designed to comply when presented with continuous data (or information) stream. Describe how the EUT complies with the requirement that it not have the ability to be coordinated with other FHSS systems in an effort to avoid the simultaneous occupancy of individual hopping frequencies by multiple transmitters. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 17 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.2.2 Description of the systems 1. According to the preset procedure of the whole network, all the stations in the automatic control network synchronously change the frequency multiple times within one second, and temporarily stay on each frequency hopping channel. Periodic synchronization signaling is sent from the primary station, instructing all slaves to simultaneously change the operating frequency, then the hopping sequence is generated. 2. The hop set shall appear as random in the near term, shall appear as evenly distributed in the long term, and sequential hops shall be randomly distributed in both direction and magnitude of change. Reference Documents 3. Channels are classified into two categories, used and unused, where used channels are part of the hopping sequence and unused channels are replaced in the hopping sequence by used channels in a pseudo-random way. Make each individual EUT meets the requirement that each of its hopping channels is used equally on average. 4. The input bandwith and transmitted bandwith are both 1MHz, the associated receiver(s) complies with the requirement that the input bandwidth matches the bandwidth of the transmitted signal. 5. Connected devices communicate on the same physical channel by synchronizing with a common clock and hopping sequence. 6. EUT isn't short burst systems. 7. EUT can't have the ability to be coordinated with other FHSS systems in an effort. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 18 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.3 Number of Hopping Frequencies 5.3.1 Limit FCC §15.247(a) (1) (iii) Frequency hopping systems operating in the 2400 MHz to 2483.5 MHz bands shall use at least 15 hopping frequencies. 5.3.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.3.3 Test Procedure The EUT must have its hopping function enabled. Use the following spectrum analyzer settings: Span = The frequency band of operation RBW = To identify clearly the individual channels, set the RBW to less than 30% of the channel spacing or the 20 dB bandwidth, whichever is smaller. VBW RBW Sweep = auto Detector function = peak Trace = max hold Allow the trace to stabilize 5.3.4 Test Result Please refer to ANNEX A.1. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 19 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.4 Peak Output Power 5.4.1 Test Limit FCC § 15.247(b) For frequency hopping systems operating in the 2400-2483.5 MHz band employing at least 75 nonoverlapping hopping channels band: 1 watt. For all other frequency hopping systems in the 2400-2483.5 MHz band: 0.125 watts. 5.4.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.4.3 Test Procedure The Module operates at hopping-off test mode. The lowest, middle and highest channels are selected to perform testing to verify the conducted RF output peak power of the Module. Use the following spectrum analyzer settings: Span = approximately 5 times the 20 dB bandwidth, centered on a hopping channel RBW > the 20 dB bandwidth of the emission being measured VBW RBW Sweep = auto Detector function = peak Trace = max hold Allow the trace to stabilize. 5.4.4 Test Result Please refer to ANNEX A.2. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 20 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.5 Occupied Bandwidth 5.5.1 Limit FCC §15.247(a) Measurement of the 20dB bandwidth of the modulated signal. 5.5.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.5.3 Test Procedure Use the following spectrum analyzer settings: Span = approximately 2 to 5 times the 20 dB bandwidth, centered on a hopping channel RBW = in the range of 1% to 5% of the OBW VBW RBW Sweep = auto Detector function = peak Trace = max hold The EUT should be transmitting at its maximum data rate, Allow the trace to stabilize. 5.5.4 Test Result Please refer to ANNEX A.3. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 21 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.6 Carrier Frequency Separation 5.6.1 Limit FCC §15.247(a) Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 kHz or the 2/3 of the 20 dB bandwidth of the hopping channel, whichever is greater. 5.6.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.6.3 Test Procedure The EUT must have its hopping function enabled. Use the following spectrum analyzer settings: Span = wide enough to capture the peaks of two adjacent channels Resolution (or IF) Bandwidth (RBW) 1% of the span Video (or Average) Bandwidth (VBW) RBW Sweep = auto Detector function = peak Trace = max hold Allow the trace to stabilize. Use the marker-delta function to determine the separation between the peaks of the adjacent channels. 5.6.4 Test Result Please refer to ANNEX A.4. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 22 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.7 Time of Occupancy (Dwell time) 5.7.1 Limit FCC §15.247(a) Frequency hopping systems in the 2400 MHz - 2483.5 MHz band shall use at least 15 non-overlapping channels. The average time of occupancy on any channel shall not be greater than 0.4 seconds within a period of 0.4 seconds multiplied by the number of hopping channels employed. Frequency hopping systems may avoid or suppress transmissions on a particular hopping frequency provided that a minimum of 15 channels are used. 5.7.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.7.3 Test Procedure The EUT shall have its hopping function enabled. Use the following spectrum analyzer settings: Span: Zero span, centered on a hopping channel RBW shall be channel spacing and where possible RBW should be set >> 1 / T, where T is the expected dwell time per channel Sweep: As necessary to capture the entire dwell time per hopping channel; where possible use a video trigger and trigger delay so that the transmitted signal starts a little to the right of the start of the plot. The trigger level might need slight adjustment to prevent triggering when the system hops on an adjacent channel; a second plot might be needed with a longer sweep time to show two successive hops on a channel Detector function: Peak Trace: Max hold Use the marker-delta function to determine the transmit time per hop. If this value varies with different modes of operation (data rate, modulation format, number of hopping channels, etc.), then repeat this test for each variation in transmit time. The average time of occupancy on any channel within the Period can be calculated with formulas: For GFSK and 8-DPSK: For DH1 package type {Total of Dwell} = {Pulse Time} * (1600 / 2) / {Number of Hopping Frequency} * {Period} {Period} = 0.4 s * {Number of Hopping Frequency} For DH3 package type {Total of Dwell} = {Pulse Time} * (1600 / 4) / {Number of Hopping Frequency} * {Period} {Period} = 0.4 s * {Number of Hopping Frequency} For DH5 package type {Total of Dwell} = {Pulse Time} * (1600 / 6) / {Number of Hopping Frequency} * {Period} {Period} = 0.4 s * {Number of Hopping Frequency} For AFH Mode: For DH1 package type {Total of Dwell} = {Pulse Time} * (800 / 2) / {Number of Hopping Frequency} * {Period} Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 23 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 {Period} = 0.4 s * {Number of Hopping Frequency} For DH3 package type {Total of Dwell} = {Pulse Time} * (800 / 4) / {Number of Hopping Frequency} * {Period} {Period} = 0.4 s * {Number of Hopping Frequency} For DH5 package type {Total of Dwell} = {Pulse Time} * (800 / 6) / {Number of Hopping Frequency} * {Period} {Period} = 0.4 s * {Number of Hopping Frequency} The lowest, middle and highest channels are selected to perform testing to record the dwell time of each occupation measured in this channel, which is called Pulse Time here. 5.7.4 Test Result Please refer to ANNEX A.5. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 24 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.8 Conducted Spurious Emission & Authorized-band band-edge 5.8.1 Limit FCC §15.247(d) In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. 5.8.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.8.3 Test Procedure Use the following spectrum analyzer settings: Span = wide enough to capture the peak level of the in-band emission and all spurious emissions (e.g., harmonics) from the lowest frequency generated in the EUT up through the 10th harmonic. Typically, several plots are required to cover this entire span. RBW = 100 kHz VBW = 300 kHz Sweep = auto Detector function = peak Trace = max hold Allow the trace to stabilize 5.8.4 Test Result Please refer to ANNEX A.6. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 25 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.9 Conducted Emission 5.9.1 Limit FCC §15.207 For an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150 kHz to 30 MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency range (MHz) 0.15 - 0.50 0.50 - 5 0.50 - 30 Conducted Limit (dBµV) Quai-peak Average 66 to 56 56 to 46 56 46 60 50 5.9.2 Test Setup See section 4.5.2 for test setup description for the AC power supply port. The photo of test setup please refer to ANNEX B. 5.9.3 Test Procedure The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Refer to recorded points and plots below. Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz) for which the device is capable of operation. A device rated for 50/60 Hz operation need not be tested at both frequencies provided the radiated and line conducted emissions are the same at both frequencies. 5.9.4 Test Result Please refer to ANNEX A.7. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 26 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.10 Radiated Spurious Emission 5.10.1 Limit FCC §15.209&15.247(d) Radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960 Field Strength (µV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500 Measurement Distance (m) 300 30 30 3 3 3 3 Note: 1. Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)]. 2. In the emission tables above, the tighter limit applies at the band edges. 3. For Above 1000 MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. 4. For above 1000 MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK). 5.10.2 Test Setup See section 4.5.3 to 4.5.5 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.10.3 Test Procedure The measurement frequency range is from 9 kHz to the 10th harmonic of the fundamental frequency. The Turn Table is actuated to turn from 0° to 360°, and both horizontal and vertical polarizations of the Test Antenna are used to find the maximum radiated power. Mid channels on all channel bandwidth verified. Only the worst RB size/offset presented. The power of the EUT transmitting frequency should be ignored. All Spurious Emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 27 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 Use the following spectrum analyzer settings: Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1 GHz, 100 kHz for f < 1 GHz VBW RBW Sweep = auto Detector function = peak Trace = max hold For measurement below 1GHz, If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the peak emission level will be reported, Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported. 5.10.4 Test Result Please refer to ANNEX A.8. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 28 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 5.11Band Edge (Restricted-band band-edge) 5.11.1 Limit FCC §15.209&15.247(d) Radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). 5.11.2 Test Setup See section 4.5.3 to 4.5.5 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.11.3 Test Procedure The measurement frequency range is from 9 kHz to the 10th harmonic of the fundamental frequency. The Turn Table is actuated to turn from 0° to 360°, and both horizontal and vertical polarizations of the Test Antenna are used to find the maximum radiated power. Mid channels on all channel bandwidth verified. Only the worst RB size/offset presented. The power of the EUT transmitting frequency should be ignored. All Spurious Emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Use the following spectrum analyzer settings: Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1 GHz, 100 kHz for f < 1 GHz VBW RBW Sweep = auto Detector function = peak Trace = max hold For measurement below 1GHz, If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the peak emission level will be reported, Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported. 5.11.4 Test Result Please refer to ANNEX A.9. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 29 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 ANNEX A TEST RESULT A.1 Number of Hopping Frequency Test Data Test Mode GFSK 8-DPSK Frequency Block (MHz) 2400 - 2483.5 2400 - 2483.5 Measured Channel Numbers 79 79 Min. Limit 15 15 Test Plots GFSK 2.4 GHz ~ 2.4415 GHz GFSK 2.4415 GHz ~ 2.4835 GHz Verdict Pass Pass 8-DPSK 2.4 GHz ~ 2.4415 GHz 8-DPSK 2.4415 GHz ~ 2.4835 GHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 30 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 A.2 Peak Output Power Peak Power Test Data Measured Output Peak Power Channel GFSK /4-DQPSK 8-DPSK dBm mW dBm mW dBm mW Low 13.07 20.29 12.25 16.80 12.33 17.11 Middle 12.72 18.72 11.91 15.51 11.97 15.74 High 13.22 20.98 12.44 17.53 12.98 19.87 Limit dBm mW 21 125 Verdict Pass Pass Pass Test Plots GFSK LOW CHANNEL GFSK MIDDLE CHANNEL GFSK HIGH CHANNEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 31 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 /4-DQPSK LOW CHANNEL /4-DQPSK MIDDLE CHANNEL /4-DQPSK HIGH CHANNEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 32 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK LOW CHANNEL 8-DPSK MIDDLE CHANNEL 8-DPSK HIGH CHANNEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 33 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 A.3 20 dB and 99% bandwidth Test Data Channel Low Middle High Channel Low Middle High Channel Low Middle High GFSK 20 dB Bandwidth (MHz) 0.869900 0.869900 0.877400 /4-DQPSK 20 dB Bandwidth (MHz) 1.259800 1.267300 1.259800 8-DPSK 20 dB Bandwidth (MHz) 1.260000 1.260000 1.260000 99% Bandwidth (MHz) 0.755370 0.755410 0.756110 99% Bandwidth (MHz) 1.141900 1.141700 1.141300 99% Bandwidth (MHz) 1.140500 1.142100 1.144700 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 34 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 Test Plots 20 dB Bandwidth GFSK LOW CHANNEL GFSK MIDDLE CHANNEL GFSK HIGH CHANNEL /4-DQPSK LOW CHANNEL /4-DQPSK MIDDLE CHANNEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 35 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 /4-DQPSK HIGH CHANNEL 8-DPSK LOW CHANNEL 8-DPSK MIDDLE CHANNEL 8-DPSK HIGH CHANNEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 36 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 99% Bandwidth GFSK LOW CHANNEL GFSK MIDDLE CHANNEL GFSK HIGH CHANNEL /4-DQPSK LOW CHANNEL /4-DQPSK MIDDLE CHANNEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 37 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 /4-DQPSK HIGH CHANNEL 8-DPSK LOW CHANNEL 8-DPSK MIDDLE CHANNEL 8-DPSK HIGH CHANNEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 38 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 A.4 Hopping Frequency Separation Test Data Mode GFSK 8-DPSK Test Plots GFSK Frequency separation (MHz) 1.000 1.000 2/3 of the 20 dB Bandwidth (MHz) 0.585 0.840 8-DPSK Verdict Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 39 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 A.5 Average Time of Occupancy Test Data DH Packet DH 1 DH 3 DH 5 DH Packet 3DH 1 3DH 3 3DH 5 DH Packet DH 1 DH 3 DH 5 Pulse Width (ms) 0.3728 1.6270 2.8760 Pulse Width (ms) 0.38080 1.63400 2.88800 Pulse Width (ms) 0.37280 1.62700 2.87600 GFSK Total of Dwell (ms) 119.296 260.320 306.773 8-DPSK Total of Dwell (ms) 121.856 261.440 308.053 AFH Mode Total of Dwell (ms) 59.648 130.160 153.387 Limit (sec) 0.4 0.4 0.4 Limit (sec) 0.4 0.4 0.4 Limit (sec) 0.4 0.4 0.4 Verdict Pass Pass Pass Verdict Pass Pass Pass Verdict Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 40 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 Test Plots GFSK DH1 GFSK DH3 GFSK DH5 8-DPSK 3DH1 8-DPSK 3DH3 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 41 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK 3DH5 AFH Mode DH1 AFH Mode DH3 AFH Mode DH5 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 42 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 A.6 Conducted Spurious Emissions & Authorized-band band-edge Test Data Channel Low Middle High Channel Low Middle High Mode GFSK 8-DPSK Measured Max. Out of Band Emission (dBm) -35.16 -34.91 -35.49 Measured Max. Out of Band Emission (dBm) -35.20 -36.06 -35.42 Measured Max. Out of Band Emission (dBm) -35.45 -35.90 GFSK Limit (dBm) Carrier Level Calculated 20 dBc Limit 12.70 -7.30 12.79 -7.21 12.73 -7.27 8-DPSK Limit (dBm) Carrier Level Calculated 20 dBc Limit 12.51 -7.49 11.44 -8.56 12.97 -7.03 Hopping Mode Limit (dBm) Carrier Level Calculated 20 dBc Limit 13.83 -6.17 12.71 -7.30 Verdict Pass Pass Pass Verdict Pass Pass Pass Verdict Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 43 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 Test Plots GFSK LOW CHANNEL, CARRIER LEVEL GFSK LOW CHANNEL, BAND EDGE GFSK LOW CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK LOW CHANNEL, SPURIOUS 3 GHz ~ 25 GHz GFSK MIDDLE CHANNEL, CARRIER LEVEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 44 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 GFSK MIDDLE CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK MIDDLE CHANNEL, SPURIOUS 3 GHz ~ 25 GHz GFSK HIGH CHANNEL, CARRIER LEVEL GFSK HIGH CHANNEL, BAND EDGE GFSK HIGH CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK HIGH CHANNEL, SPURIOUS 3 GHz ~ 25 GHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 45 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK LOW CHANNEL, CARRIER LEVEL 8-DPSK LOW CHANNEL, BAND EDGE 8-DPSK LOW CHANNEL, SPURIOUS 30 MHz ~ 3 GHz 8-DPSK LOW CHANNEL, SPURIOUS 3 GHz ~ 25 GHz 8-DPSK MIDDLE CHANNEL, CARRIER LEVEL Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 46 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK MIDDLE CHANNEL, SPURIOUS 30 MHz ~ 3 GHz 8-DPSK MIDDLE CHANNEL, SPURIOUS 3 GHz ~ 25 GHz 8-DPSK HIGH CHANNEL, CARRIER LEVEL 8-DPSK HIGH CHANNEL, BAND EDGE 8-DPSK HIGH CHANNEL, SPURIOUS 30 MHz ~ 3 GHz 8-DPSK HIGH CHANNEL, SPURIOUS 3 GHz ~ 25 GHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 47 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 GFSK HOPPING, CARRIER LEVEL GFSK HOPPING BAND EDGE (LOW) GFSK HOPPING BAND EDGE (HIGH) GFSK Hopping Mode, SPURIOUS 30 MHz ~ 3 GHz GFSK Hopping Mode, SPURIOUS 3GHz ~ 25 GHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 48 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK HOPPING, CARRIER LEVEL 8-DPSK Hopping BAND EDGE (LOW) 8-DPSK Hopping BAND EDGE (HIGH) 8-DPSK Hopping Mode, SPURIOUS 30 MHz ~ 3 GHz 8-DPSK Hopping Mode, SPURIOUS 3GHz ~ 25 GHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 49 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 A.7 Conducted Emissions Note 1: The EUT is working in the Normal link mode. All modes have been tested and normal link mode is worst. Note 2: Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 60 Hz and 240 VAC, 50 Hz) for which the device is capable of operation. So, The configuration 120 VAC, 60 Hz and 240 VAC, 50 Hz were tested respectively, but only the worst configuration (120 VAC, 60 Hz ) shown here. Note 3: Results (dBuV) = Original reading level of Spectrum Analyzer (dBuV) + Factor (dB) Test Data and Plots PHASE L No. Frequency Results (MHz) (dBuV) 1 0.154 38.16 1** 0.154 26.92 2 0.252 39.25 2** 0.252 28.15 3 0.398 37.76 3** 0.398 25.35 4 2.338 32.45 4** 2.338 19.84 5 12.724 32.18 5** 12.724 18.17 6 21.662 42.06 6** 21.662 34.14 Factor (dB) 10.11 10.11 10.05 10.05 10.63 10.63 10.58 10.58 12.04 12.04 13.48 13.48 Limit (dBuV) 65.78 55.78 61.69 51.69 57.90 47.90 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 27.62 28.86 22.44 23.54 20.14 22.55 23.55 26.16 27.82 31.83 17.94 15.86 Detector Line Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 50 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 PHASE N No. Frequency Results (MHz) (dBuV) 1 0.158 37.97 1** 0.158 26.44 2 0.252 38.71 2** 0.252 28.05 3 0.442 36.92 3** 0.442 23.50 4 2.014 32.09 4** 2.014 17.95 5 5.978 30.80 5** 5.978 17.05 6 22.474 41.79 6** 22.474 30.96 Factor (dB) 10.10 10.10 10.05 10.05 10.59 10.59 10.44 10.44 10.83 10.83 13.35 13.35 Limit (dBuV) 65.57 55.57 61.69 51.69 57.02 47.02 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 27.60 29.13 22.98 23.64 20.10 23.52 23.91 28.05 29.20 32.95 18.21 19.04 Detector Line Peak N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 51 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 A.8 Radiated Spurious Emission Note 1: The symbol of "--" in the table which means not application. Note 2: For the test data above 1 GHz, according the ANSI C63.10-2013, where limits are specified for both average and peak (or quasi-peak) detector functions, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an average measurement. Note 3: The EUT is working in the Normal link mode below 1 GHz. All modes have been tested and DH5Hopping mode is the worst. Note 4: Results (dBuV/m) = Original reading level of Spectrum Analyzer (dBuV/m) + Factor (dB) The low frequency, which started from 9 kHz to 30 MHz, was pre-scanned and the result which was 20 dB lower than the limit line per 15.31(o) was not reported. Test Data and Plots 30 MHz to 1 GHz, ANT H No. Frequency Results (MHz) (dBuV/m) 1 87.036 16.50 2 133.354 24.03 3 265.274 21.83 4 313.483 24.17 5 361.934 23.39 6 399.618 22.96 Factor (dB) -29.39 -30.02 -24.52 -23.31 -21.93 -20.95 Limit (dBuV/m) 40.0 43.5 46.0 46.0 46.0 46.0 Margin (dB) 23.50 19.47 24.17 21.83 22.61 23.04 Detector Peak Peak Peak Peak Peak Peak Table Height (Degree) (cm) 239.00 200 0.00 200 70.00 100 52.00 100 55.00 100 69.00 100 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 52 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 30 MHz to 1 GHz, ANT V No. Frequency Results (MHz) (dBuV/m) 1 31.746 33.26 2 38.536 32.18 3 87.570 23.70 4 135.633 23.40 5 146.691 24.17 6 289.184 25.03 Factor (dB) -29.04 -27.08 -29.25 -30.12 -30.23 -23.93 Limit (dBuV/m) 40.0 40.0 40.0 43.5 43.5 46.0 Margin (dB) 6.74 7.82 16.30 20.10 19.33 20.97 Detector Peak Peak Peak Peak Peak Peak Table Height (Degree) (cm) 109.00 100 247.00 100 5.00 100 163.00 100 357.00 100 293.00 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 53 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 Note 1: The marked spikes near 2400 MHz with circle should be ignored because they are Fundamental signal. Note 2: The spurious from 18GHz-25GHz is noise only, do not show on the report. GFSK LOW CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results (MHz) (dBuV/m) 1 1410.800 40.42 1** 1410.800 30.45 2 2402.000 101.98 2** 2402.000 101.44 3 2965.300 48.95 3** 2965.300 38.66 4 4804.500 46.75 4** 4804.500 42.19 5 7877.250 53.09 5** 7877.250 43.99 6 17554.999 47.65 6** 17554.999 40.28 Factor (dB) -19.77 -19.77 -14.72 -14.72 -12.01 -12.01 -4.93 -4.93 0.52 0.52 6.44 6.44 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.58 23.55 -27.98 -47.44 25.05 15.34 27.25 11.81 20.91 10.01 26.35 13.72 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 335.00 335.00 288.00 288.00 33.00 33.00 31.00 31.00 40.00 40.00 305.00 305.00 Height (cm) 300 300 200 200 150 150 150 150 100 100 400 400 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 54 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 GFSK LOW CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results (MHz) (dBuV/m) 1 1466.200 40.56 1** 1466.200 30.59 2 2402.000 90.81 2** 2402.000 90.37 3 2732.500 48.89 3** 2732.500 39.77 4 4804.000 46.94 4** 4804.000 41.52 5 7862.000 53.37 5** 7862.000 45.32 6 17547.500 48.19 6** 17547.500 41.03 Factor (dB) -19.82 -19.82 -14.72 -14.72 -11.62 -11.62 -4.89 -4.89 0.14 0.14 6.45 6.45 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.44 23.41 -16.81 -36.37 25.11 14.23 27.06 12.48 20.63 8.68 25.81 12.97 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 0.00 0.00 127.00 127.00 15.00 15.00 48.00 48.00 317.00 317.00 217.00 217.00 Height (cm) 100 100 150 150 200 200 150 150 200 200 200 200 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 55 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 GFSK MIDDLE CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results (MHz) (dBuV/m) 1 1276.700 40.46 1** 1276.700 31.00 2 2441.000 102.49 2** 2441.000 101.99 3 2910.900 49.22 3** 2910.900 39.26 4 4882.000 45.80 4** 4882.000 41.69 5 7881.000 53.30 5** 7881.000 44.27 6 17807.499 47.62 6** 17807.499 39.60 Factor (dB) -19.72 -19.72 -13.76 -13.76 -11.91 -11.91 -6.16 -6.16 0.30 0.30 6.32 6.32 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.54 23.00 -28.49 -47.99 24.78 14.74 28.20 12.31 20.70 9.73 26.38 14.40 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 303.00 303.00 140.00 140.00 224.00 224.00 312.00 312.00 42.00 42.00 1.00 1.00 Height (cm) 100 100 200 200 200 200 150 150 400 400 400 400 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 56 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 GFSK MIDDLE CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results (MHz) (dBuV/m) 1 1331.300 41.48 1** 1331.300 30.60 2 2441.000 90.08 2** 2441.000 89.62 3 2916.200 48.95 3** 2916.200 39.07 4 4976.750 48.75 4** 4976.750 39.90 5 7495.250 53.19 5** 7495.250 43.91 6 17592.500 47.26 6** 17592.500 38.90 Factor (dB) -19.77 -19.77 -13.76 -13.76 -11.75 -11.75 -4.08 -4.08 -0.43 -0.43 5.95 5.95 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 32.52 23.40 -16.08 -35.62 25.05 14.93 25.25 14.10 20.81 10.09 26.74 15.10 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 95.00 95.00 10.00 10.00 360.00 360.00 321.00 321.00 133.00 133.00 334.00 334.00 Height (cm) 100 100 150 150 150 150 100 100 100 100 300 300 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 57 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 GFSK HIGH CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results (MHz) (dBuV/m) 1 1296.700 40.59 1** 1296.700 30.58 2 2480.000 103.54 2** 2480.000 103.10 3 2943.300 48.68 3** 2943.300 38.94 4 4960.250 49.37 4** 4960.250 45.16 5 7870.750 53.29 5** 7870.750 45.10 6 17547.500 47.91 6** 17547.500 41.31 Factor (dB) -19.67 -19.67 -13.06 -13.06 -12.37 -12.37 -3.85 -3.85 0.42 0.42 6.45 6.45 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.41 23.42 -29.54 -49.10 25.32 15.06 24.63 8.84 20.71 8.90 26.09 12.69 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 262.00 262.00 143.00 143.00 36.00 36.00 311.00 311.00 197.00 197.00 261.00 261.00 Height (cm) 100 100 150 150 200 200 150 150 200 200 400 400 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 58 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 GFSK HIGH CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results (MHz) (dBuV/m) 1 1533.700 40.36 1** 1533.700 30.06 2 2480.000 92.33 2** 2480.000 91.91 3 2735.000 48.91 3** 2735.000 39.66 4 4960.250 47.58 4** 4960.250 42.36 5 7488.750 53.60 5** 7488.750 43.62 6 17812.500 47.65 6** 17812.500 39.70 Factor (dB) -19.69 -19.69 -13.06 -13.06 -11.84 -11.84 -3.85 -3.85 -0.33 -0.33 6.19 6.19 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.64 23.94 -18.33 -37.91 25.09 14.34 26.42 11.64 20.40 10.38 26.35 14.30 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 75.00 75.00 65.00 65.00 203.00 203.00 292.00 292.00 232.00 232.00 200.00 200.00 Height (cm) 300 300 150 150 200 200 150 150 100 100 300 300 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 59 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK LOW CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results (MHz) (dBuV/m) 1 1296.300 40.46 1** 1296.300 31.42 2 2401.700 100.48 2** 2401.700 99.09 3 2989.000 48.49 3** 2989.000 39.20 4 4957.750 49.02 4** 4957.750 39.92 5 7496.750 52.82 5** 7496.750 44.17 6 17545.001 47.32 6** 17545.001 39.78 Factor (dB) -19.65 -19.65 -14.72 -14.72 -12.36 -12.36 -3.80 -3.80 -0.55 -0.55 6.40 6.40 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.54 22.58 -26.48 -45.09 25.51 14.80 24.98 14.08 21.18 9.83 26.68 14.22 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 255.00 255.00 183.00 183.00 72.00 72.00 320.00 320.00 360.00 360.00 7.00 7.00 Height (cm) 100 100 150 150 150 150 200 200 300 300 300 300 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 60 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK LOW CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results (MHz) (dBuV/m) 1 1161.200 40.42 1** 1161.200 29.40 2 2402.100 88.93 2** 2402.100 88.40 3 2903.600 49.19 3** 2903.600 39.43 4 4958.000 48.98 4** 4958.000 41.10 5 7872.000 54.25 5** 7872.000 44.58 6 17552.501 48.18 6** 17552.501 41.37 Factor (dB) -20.48 -20.48 -14.72 -14.72 -12.25 -12.25 -3.80 -3.80 0.44 0.44 6.47 6.47 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.58 24.60 -14.93 -34.40 24.81 14.57 25.02 12.90 19.75 9.42 25.82 12.63 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 351.00 351.00 118.00 118.00 145.00 145.00 49.00 49.00 127.00 127.00 270.00 270.00 Height (cm) 300 300 100 100 200 200 400 400 300 300 300 300 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 61 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK MIDDLE CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results (MHz) (dBuV/m) 1 1285.100 40.76 1** 1285.100 31.96 2 2440.900 101.52 2** 2440.900 100.33 3 2910.700 48.93 3** 2910.700 39.07 4 4978.250 49.19 4** 4978.250 40.18 5 7867.250 53.76 5** 7867.250 44.50 6 17757.499 47.72 6** 17757.499 39.65 Factor (dB) -19.66 -19.66 -13.77 -13.77 -11.92 -11.92 -4.13 -4.13 0.35 0.35 5.25 5.25 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.24 22.04 -27.52 -46.33 25.07 14.93 24.81 13.82 20.24 9.50 26.28 14.35 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 180.00 180.00 281.00 281.00 116.00 116.00 255.00 255.00 209.00 209.00 136.00 136.00 Height (cm) 400 400 150 150 100 100 100 100 400 400 100 100 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 62 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK MIDDLE CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results (MHz) (dBuV/m) 1 1280.300 40.49 1** 1280.300 30.77 2 2440.700 87.73 2** 2440.700 83.85 3 2916.300 48.78 3** 2916.300 39.21 4 4958.750 48.64 4** 4958.750 40.17 5 7905.500 53.63 5** 7905.500 43.52 6 17822.501 47.67 6** 17822.501 39.32 Factor (dB) -19.71 -19.71 -13.79 -13.79 -11.75 -11.75 -3.81 -3.81 0.15 0.15 5.91 5.91 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.51 23.23 -13.73 -29.85 25.22 14.79 25.36 13.83 20.37 10.48 26.33 14.68 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 293.00 293.00 309.00 309.00 286.00 286.00 156.00 156.00 277.00 277.00 77.00 77.00 Height (cm) 200 200 200 200 150 150 400 400 300 300 400 400 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 63 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK HIGH CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results (MHz) (dBuV/m) 1 1504.900 40.43 1** 1504.900 30.65 2 2480.000 101.83 2** 2480.000 98.95 3 2984.800 49.01 3** 2984.800 38.42 4 4959.750 49.29 4** 4959.750 41.73 5 7716.250 53.43 5** 7716.250 44.08 6 17562.499 47.95 6** 17562.499 40.13 Factor (dB) -19.56 -19.56 -13.06 -13.06 -12.37 -12.37 -3.82 -3.82 -1.53 -1.53 6.34 6.34 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.57 23.35 -27.83 -44.95 24.99 15.58 24.71 12.27 20.57 9.92 26.05 13.87 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 22.00 22.00 229.00 229.00 79.00 79.00 22.00 22.00 40.00 40.00 177.00 177.00 Height (cm) 300 300 150 150 150 150 200 200 100 100 100 100 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 64 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK HIGH CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results (MHz) (dBuV/m) 1 1499.700 40.58 1** 1499.700 30.45 2 2480.200 91.22 2** 2480.200 88.55 3 2912.500 48.47 3** 2912.500 39.36 4 4990.750 48.70 4** 4990.750 39.50 5 7871.750 53.65 5** 7871.750 44.24 6 17535.001 48.99 6** 17535.001 41.97 Factor (dB) -19.49 -19.49 -13.05 -13.05 -11.87 -11.87 -4.13 -4.13 0.43 0.43 6.21 6.21 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 33.42 23.55 -17.22 -34.55 25.53 14.64 25.30 14.50 20.35 9.76 25.01 12.03 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 345.00 345.00 224.00 224.00 212.00 212.00 311.00 311.00 294.00 294.00 91.00 91.00 Height (cm) 300 300 150 150 150 150 100 100 400 400 100 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 65 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 A.9 Band Edge (Restricted-band band-edge) Note 1: The lowest and highest channels are tested to verify the band edge emissions. Please refer to the following the plots for emissions values. Note 2: The test data all are tested in the vertical and horizontal antenna which the trace is max hold. So these plots have shown the worst case. Note 3: According the ANSI C63.10-2013, where limits are specified for both average and peak (or quasipeak) detector functions, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an average measurement. Note 4: The Level (dBuV/m) has been corrected by factor. Test Data and Plots GFSK LOW CHANNEL No. Frequency Results (MHz) (dBuV/m) 1 2380.833 54.05 1** 2380.833 42.21 2 2390.000 52.45 2** 2390.000 42.34 3 2388.833 52.57 3** 2388.833 42.70 Factor (dB) -2.31 -2.31 -2.35 -2.35 -2.31 -2.31 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 19.95 11.79 21.55 11.66 21.43 11.30 Detector Peak AV Peak AV Peak AV Table (Degree) 186.00 186.00 117.00 117.00 356.00 356.00 Height (cm) 200 200 150 150 150 150 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 66 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 GFSK HIGH CHANNEL No. Frequency (MHz) 1 2483.500 1** 2483.500 2 2490.200 2** 2490.200 3 2484.300 3** 2484.300 Results (dBuV/m) 54.96 43.75 56.04 43.52 54.08 44.07 Factor (dB) -0.86 -0.86 -0.85 -0.85 -0.84 -0.84 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 19.04 10.25 17.96 10.48 19.92 9.93 Detector Peak AV Peak AV Peak AV Table (Degree) 136.00 136.00 278.00 278.00 152.00 152.00 Height (cm) 200 200 150 150 100 100 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 67 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK LOW CHANNEL No. Frequency Results (MHz) (dBuV/m) 1 2385.000 55.16 1** 2385.000 42.56 2 2390.000 52.76 2** 2390.000 42.40 3 2386.500 53.35 3** 2386.500 42.65 Factor (dB) -2.22 -2.22 -2.35 -2.35 -2.21 -2.21 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 18.84 11.44 21.24 11.60 20.65 11.35 Detector Peak AV Peak AV Peak AV Table (Degree) 224.00 224.00 44.00 44.00 284.00 284.00 Height (cm) 150 150 100 100 150 150 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 68 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 8-DPSK HIGH CHANNEL No. Frequency Results (MHz) (dBuV/m) 1 2483.500 54.38 1** 2483.500 44.09 2 2493.300 55.49 2** 2493.300 43.48 Factor (dB) -0.86 -0.86 -0.86 -0.86 Limit (dBuV/m) 74.0 54.0 74.0 54.0 Margin (dB) 19.62 9.91 18.51 10.52 Detector Peak AV Peak AV Table (Degree) 337.00 337.00 5.00 5.00 Height (cm) 150 150 200 200 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 69 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 ANNEX B TEST SETUP PHOTOS Please refer the document "BL-SZ2460066-AR.PDF". ANNEX C EUT EXTERNAL PHOTOS Please refer the document "BL-SZ2460066-AW.PDF". ANNEX D EUT INTERNAL PHOTOS Please refer the document "BL-SZ2460066-AI.PDF". Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 70 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-601 Statement 1. The laboratory guarantees the scientificity, accuracy and impartiality of the test, and is responsible for all the information in the report, except the information provided by the customer. The customer is responsible for the impact of the information provided on the validity of the results. 2. The report without China inspection body and laboratory Mandatory Approval (CMA) mark has no effect of proving to the society. 3. For the report with CNAS mark or A2LA mark, the items marked with "" are not within the accredited scope. 4. This report is invalid if it is altered, without the signature of the testing and approval personnel, or without the "inspection and testing dedicated stamp" or test report stamp. 5. The test data and results are only valid for the tested samples provided by the customer. 6. This report shall not be partially reproduced without the written permission of the laboratory. 7. Any objection shall be raised to the laboratory within 30 days after receiving the report. --END OF REPORT-- Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 71 / 71 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. ChinaMicrosoft Word LTSC 钛和检测认证集团股份有限公司