Weintek mTV Series Installation Instructions

1 Installation and Startup Guide

This document covers the installation of mTV Series. For detailed specifications and operation, please refer to the Brochure and EasyBuilder Pro User Manual.

Install Environment

Electrical Environment

The mTV Series has been tested to conform to European CE requirements. This means that the circuitry is designed to resist the effects of electrical noise. This does not guarantee noise immunity in severe cases. Proper wire routing and grounding will ensure proper operation.

2 Unpacking the Unit

Unpack and check the delivery. If damage is found, notify the supplier.

NOTE: Place the unit on a stable surface during installation. Dropping it or letting it fall may cause damage.

3 Installation Instructions

Rail mounting: DIN rail 35mm

Panel mounting: Use two M4 or #8 panhead screws, mounting hole size is 4.6mm

4 Power Connections

NOTE: Connect positive DC line to the '+' terminal and the DC ground to the '-' terminal.

24VDC FG

5 System Settings

Connect mTV with TV via HDMI™ cable.

When mTV is powered up and displays image, click the system setting button. (Default System Password: 111111)

It is necessary to connect the mTV to your network through a RJ-45 cable.

Go to the Network tab, you may choose to auto get DHCP IP, or designate your own IP.

[Screenshot of System Settings Network Tab showing IP configuration options]

6 EasyBuilder Pro Software Settings

Launch EasyBuilder Pro software, select your project file, press F7 shortcut key to open the download dialog box: Select Ethernet > IP tab > Enter your mTV IP > Click Download to download this project file to mTV.

(Please refer to EasyBuilder Pro User Manual for software operation details)

7 Communication Connection

NOTE: COM2 and COM3 [RS485] support MPI 187.5K, please use one at a time.

PIN#COM1 [RS-232]COM2 [RS-485] 2WCOM3 [RS-485] 2W
1Data+
2RxD
3TxD
4Data-
5GNDGNDGND
6Data+Rx+
7Data-Rx-
8Tx+
9Tx-

8 DIP SW Settings

SW1SW2Mode
OFFOFFNormal Mode
ONOFFHide HMI System Setting Bar
OFFONBoot Loader Mode
ONONRestore Factory Default

9 Battery Replacement

Battery replacement shall be performed by qualified personnel only and care must be taken when handling lithium batteries. For more information on battery replacement and disposal considerations, please refer to the following link:

http://www.weintek.com/download/MT8000/eng/FAQ/FAQ_103_Replace_Battery_en.pdf

CAUTION

DANGER

The system designer should be aware that devices in Controller systems could fail and thereby create an unsafe condition. Furthermore, electrical interference in an operator interface can lead to equipment start-up, which could result in property damage and/or physical injury to the operator.

If you use any programmable control systems that require an operator, be aware that this potential safety hazard exists and take appropriate precautions. Although the specific design steps depend on your particular application, the following precautions generally apply to installation of solid-state programmable control devices, and conform to the guidelines for installation of Controllers recommended in NEMA ICS 3-304 Control Standards.

Hardware Considerations

To conform with ICS Safety Recommendations, checks should be placed in the controller to ensure that all writable registers that control critical parts of plant or machinery have limit checks built into the program, with an out-of-limit safe shut down procedure to ensure safety of personnel.

Programming Considerations

With ICS Safety Recommendations, checks should be placed in the controller to ensure that all writable registers that control critical parts of plant or machinery have limit checks built into the program, with an out-of-limit safe shut down procedure to ensure safety of personnel.

Limited Warranty

This product is limited warranted against defects in design and manufacture. The proven defective product will either be repaired or replaced, at Weintek's discretion. This warranty shall not cover any product which is:

GMEETV000_mTV_Installation_181107

The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI licensing Administrator, Inc.

PDF preview unavailable. Download the PDF instead.

Installation instruction mTV series ?v=1666699681 Microsoft Word 2010

Related Documents

PreviewWeintek MT8091XE 9.7" TFT HMI Touchscreen Panel
Detailed specifications and features of the Weintek MT8091XE, a 9.7-inch TFT LCD HMI touchscreen panel with fanless cooling, USB host, RS-485 and CAN bus communication, and NEMA4/IP65 front panel protection.
PreviewcMT-FHDX Series HMI Installation and Startup Guide
Comprehensive guide for installing and starting up the cMT-FHDX Series HMI, covering environment, unpacking, installation, power connections, system settings, software configuration, communication, DIP switch settings, battery replacement, and warranty information.
PreviewWeintek cMT-CTRL01 CODESYS PLC with IIoT Gateway Datasheet
Datasheet for the Weintek cMT-CTRL01, a CODESYS PLC with an IIoT Gateway, featuring a dual-core processor, 4GB Flash, 512MB RAM, multiple communication ports including Ethernet, RS-232, and RS-485, and support for various industrial protocols.
PreviewMT8090/8092XE Series HMI Installation and Startup Guide
Comprehensive installation and startup guide for the MT8090/8092XE Series HMI, covering environmental considerations, unpacking, installation, power connections, system settings, software configuration, communication, calibration, battery replacement, and warranty information.
PreviewWeintek cMT1106X Series HMI Installation Guide
Comprehensive installation instructions for the Weintek cMT1106X Series HMI, covering setup, wiring, system settings, and safety precautions.
PreviewEasyBuilder Pro: Window Operations Guide
Learn how to create, set, and delete windows in EasyBuilder Pro, including different window types, transparency settings, and editing tips for efficient project development.
PreviewSiemens S7-1200/S7-1500 PLC Connection Guide (Ethernet)
A comprehensive guide to connecting Siemens S7-1200 and S7-1500 PLCs using S7CommPlus with Symbolic Addressing over Ethernet, detailing HMI settings, PLC configurations, and tag import procedures.
PreviewWEINTEK EasyBuilder Pro Recipe Editor Guide
A comprehensive guide to using the Recipe Editor feature in WEINTEK's EasyBuilder Pro software, covering data creation, editing, and management.