File Info : application/pdf, 4 Pages, 1,010.47KB
DocumentDocumentFC-NPV and FCoE-NPV Supported Hardware · Licensing Requirements, on page 1 · FC-NPV and FCoE-NPV Supported Hardware, on page 1 Licensing Requirements For a complete explanation of Cisco NX-OS licensing recommendations and how to obtain and apply licenses, see the Cisco NX-OS Licensing Guide. FC-NPV and FCoE-NPV Supported Hardware The following table list the Cisco Nexus 9000 Series hardware that the FC-NPV and FCoE-NPV features are supported. To enable FC/FCoE NPV mode on Cisco Nexus 9000 series switches, you must configure feature-set fcoe-npv. Note For more information about enabling SAN Switching mode on Cisco Nexus 9000 series switches, see the Cisco Nexus 9000 Series NX-OS SAN Switching Configuration Guide, Release 9.3(x) Table 1: Cisco Nexus 9000 FC-NPV and FCoE-NPV Supported Hardware Switches / Line Model (PID) cards FC NP Port FCoE NP FC Edge Port Port Cisco Nexus 9200 Series Switches N9K-C9236C No N9K-C9272Q No N9K-C92160YC-X No Yes No Yes No Yes No FCoE Edge FEX Support Port Yes No Yes No Yes No FC-NPV and FCoE-NPV Supported Hardware 1 FC-NPV and FCoE-NPV Supported Hardware FC-NPV and FCoE-NPV Supported Hardware Switches / Line Model (PID) cards FC NP Port FCoE NP FC Edge Port Port Cisco Nexus 9300 Series Switches N9K-C9332PQ No N9K-C9372PX-E No N9K-C9396PX No Yes No Yes No Yes No N9K-C93180YC-EX No Yes No N9K-C93180LC-EX No Yes No N9K-C93180YC-FX Yes Yes Yes N9K-C93360YC-FX2 Yes Yes Yes Cisco Nexus N9K-X9432PQ No 9504 and 9508 Switches N9K-X9564PX No Yes No Yes No N9K-X9732C-EX No N9K-X9736C-FX No 1 Only ST FEX supported. 2 Only ST FEX supported. Yes No Yes No FCoE Edge FEX Support Port Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes 1 Yes Yes 2 Yes Yes Yes Yes Note The FCoE NPV on N9K-X9732C-EX and N9K-X9736C-FX line cards are supported only with fabric modules N9K-C9508-FM-E or N9K-C9504-FM-E. Note The N9k-9272Q switch has 72 ports. Ports 1 to 36 only operate in 40-Gb mode. Ports 37 to 71 support breakout to 4 x 10-Gb connectivity. Port 72 does not support breakout. Note The N9K-C93180LC-EX supports FCoE NPV on FEX with only one FEX model: the N2K-C2348UPQ. FC ports with FEX is not supported. Beginning with Cisco NX-OS Release 9.3(5), FC-NPV and FCoE-NPV is supported on Cisco Nexus 93360YC-FX2 switches. Beginning with Cisco NX-OS Release 9.3(5), ISSU with with FCoE (Fiber Channel over Ethernet)/FC (Fiber Channel) NPV (N-port Virtualization) is supported on some Cisco Nexus 9000 switches. An ISSU allows you to upgrade the device software while the switch continues to forward traffic. Beginning with Cisco NX-OS Release 9.3(5), you can perform an in-service software upgrade (ISSU), also known as a nondisruptive upgrade, for some Cisco Nexus 9000 switches. The default upgrade process is disruptive. Using the nondisruptive FC-NPV and FCoE-NPV Supported Hardware 2 FC-NPV and FCoE-NPV Supported Hardware FC-NPV and FCoE-NPV Supported Hardware option helps ensure a nondisruptive upgrade. (See Cisco Nexus 9000 Series NX-OS Software Upgrade and Downgrade Guide, Release 9.x for a complete list of supported platforms). Note Software Maintenance Upgrade (SMU) is not supported for FC and FCOE. Table 2: ISSU Support Matrix Switches / Line cards Model (PID) Cisco Nexus 9200 Series N9K-C9236C Switches N9K-C9272Q N9K-C92160YC-X Cisco Nexus 9300 Series N9K-C9332PQ Switches N9K-C9372PX N9K-C9372PX-E N9K-C9396PX N9K-C93180YC-EX N9K-C93180LC-EX N9K-C93180YC-FX N9K-C93360YC-FX2 Cisco Nexus 9504 and N9K-X9432PQ 9508 Switches N9K-X9464PX N9K-X9536PQ N9K-X9564PX N9K-X9636PQ N9K-X9732C-EX N9K-X9736C-FX With FC/FCOE With ST FEX NPV No N/A Yes N/A Yes N/A Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Yes No No N/A Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No N/A No N/A With AA FEX N/A N/A N/A No No No No No No No N/A No No No No No N/A N/A On the following models, the 40G GEM (Gigabit Ethernet Expansion Module) ports cannot be used to connect FCoE hosts (F ports). They can be used as FCoE uplink ports (VNP Ports): · Cisco Nexus 9332PQ switch · Cisco Nexus 9372PX switch · Cisco Nexus 9372PX-E switch FC-NPV and FCoE-NPV Supported Hardware 3 FC-NPV and FCoE-NPV Supported Hardware FC-NPV and FCoE-NPV Supported Hardware · Cisco Nexus 9396PX switch · N9K-X9464PX line cards · N9K-X9564PX line cards FC-NPV is supported on N9k-C93180YC-FX and N9k-C93360YC-FX2 switches and only the following SFPs are supported: · DS-SFP-FC8G-SW · DS-SFP-FC16G-SW · DS-SFP-FC32G-SW Note From Release 9.3(5), FC-NPV is supported on N9k-C93360YC-FX2 switch. FCoE-NPV supports the following FEX: · N2K-B22HP-P · N2K-B22IBM-P · N2K-C2232PP · N2K-C2348UPQ Beginning with Cisco NX-OS Release 9.3(5), 25G adapter QL41212H is supported on the following devices. However, when a vFC port is shut for more than 60 seconds, the FIP VLAN request retries may not be sent from the host due to a driver issue. For more information about the issue see: CSCvt83152. · N9K-C93180YC-FX · N9K-C93180YC-EX · N9K-C93360YC-FX2 FC-NPV and FCoE-NPV Supported Hardware 4