LuxePort Wallstation SILVER . iPort | iPort - Amber Tech
WallStation Manual iportproducts.com/luxeport-support GET TO KNOW LUXEPORT WALLSTATION 2 1 Turn off power to eliminate risk of shock during installation. 6) .5 ft/15 cm USB A USB C Cable 3 INSTALLATION OVERVIEW Provided in this manual are details on the 4 most common install scenarios in North America. For a more detailed install matrix including Europe and the United Kingdom please visit www.iportproducts.com/luxeport-support 4 7) Lock Tool & Hardware 5 1) WallStation 2) Wall Box Tools Required: 3) iPort PoE Splitter (inside) · 2 3/4" (70mm) Hole Saw 4) Charge Pins · Electric Drill 5) Retention Ring · Phillips Screw Driver 2 3 NEW CONSTRUCTION INSTALLATION OVERVIEW Details: Page 12 Before After Stud Bay CAT5/6 4 WHAT YOU NEED Required Components: · LuxePort WallStation 71003 - Black 71004 - Silver 71005 - White Power Requirements: · POE Splitter (Included) · POE Switch (802.3af) or POE Injector (if not using a POE Switch) - 70719 (Sold Separately) Wire Requirements: · Cat5/6 5 RETROFIT INSTALLATION OVERVIEW Details: Page 14 Before After Existing Wall 2 3/4"(70mm) Hole Saw 6 WHAT YOU NEED Required Components: · LuxePort WallStation 71003 - Black 71004 - Silver 71005 - White Power Requirements: · POE Splitter (Included) · POE Switch (802.3af) or POE Injector (if not using a POE Switch) - 70719 (Sold Separately) Wire Requirements: · Cat5/6 7 SINGLE GANG INSTALLATION OVERVIEW Details: Page 22 Before After 1G Wall Box CAT5/6 8 WHAT YOU NEED Required Components: · LuxePort WallStation 71003 - Black 71004 - Silver 71005 - White Wire Requirements: 1) Cat5/6 · LuxePort Wall Adapter Kit (Sold Separately) 71006 - Black 71007 - Silver 71008 - White Power Requirements: · POE Splitter (Included) · POE Switch (802.3af) or POE Injector (if not using a POE Switch) - 70719 (Sold Separately) 9 LAUNCHPORT WALLSTATION UPGRADE OVERVIEW Details: Page 29 Before After 10 WHAT YOU NEED Required Components: · LuxePort WallStation 71003 - Black 71004 - Silver 71005 - White Wire Requirements: · Existing 2 Conductor wire OR · CAT5/6 (if using PoE) · LuxePort Wall Adapter Kit (Sold Separately) 71006 - Black 71007 - Silver 71008 - White Power Requirements: · POE Splitter (Included) · 24V 1A Power Supply with 5.5 mm x 2.5mm barrel connector (Sold Separately) OR · 802.3af PoE Switch or iPort Injector (70719) 11 NEW CONSTRUCTION INSTALLATION DETAILS Step 1 Run new cat5/6 to the location the Luxeport Wallstation will be installed when the wall is completed. Loosely secure the Cat5/6 wire to the stud for easy retrieval. Prior to drywall, make sure to leave enough wire to work with when the wall is complete. CAT5/6 Step 2 Measure and note the location of the stud bay the cat5/6 wire is secured to for easy retrieval after drywall is installed. Continue to the next page for installation of the LuxePort Wall Box. 12 13 INSTALLING LUXEPORT WALL BOX / RETROFIT INSTALL Step 1 Use a Stud Finder to determine an unobstructed location to mount LuxePort WallStation. Use a 2-3/4" (70mm) Hole Saw and cut a hole in the desired location on the Wall. Step 2 Use a wire fishing tool and run new CAT5/6 cable to power source location. Or pull wire through the wall from a previous run prior to drywall. Step 3 The next steps are for drywall installation only. Discard the Retention Ring if installing in a solid surface such as wood or concrete. 14 Insert the LuxePort Retention Ring in the wall as shown. Starting with the split end, insert one side of the ring into the 2-3/4" hole and rotate counter clockwise until the ring is all the way behind the drywall. 15 INSTALLING LUXEPORT WALL BOX / RETROFIT INSTALL Step 4 Position fins horizontally and bend out and around the wall. Fins CAUTION: Hold onto ring so it does not fall into the wall until secured by the tabs bent around the drywall. 16 CAT5/6 INSTALLING LUXEPORT WALL BOX & RETENTION RING Step 5 Insert the LuxePort Wall Box and align the notches of the Wall Box with the tabs of the Retention Ring. Level the Wall Box and rotate the Retention Ring as needed to level. Step 6 Insert two fingers through the Wall Box to support the Retention Ring in each corner and drive in the provided mounting screws until the Wall Box and Retention Ring are both snug against the wall. Hold * Inside of wall CAUTION: watch fingers when drilling. 17 INSTALLING LUXEPORT WALL BOX & RETENTION RING Step 7 Repeat drilling of the screws for the remaining 3 corners of the Wall Box. Step 8 Once mounting is complete, bend the two exposed Retention Ring Tabs until they brake off cleanly. Note: Tabs must not protrude beyond the legnth of the Wall Box for the LuxePort Wall Station to sit flush on the wall. Trim the tabs as needed. 18 19 INSTALLING PoE SPLITTER AND WALLSTATION Step 9 Connect the Cat5/6 cable to the RJ45 jack on the splitter. Connect the USB cable to the splitter and the other end to the WallStation. Place the Splitter into the Wall Box. Step 10 Place WallStation against wall. Orient Charge Pins downward. Use the provided lock tool to attach the WallStation to the Wall Box and secure all four mounting screws making sure to turn COUNTER CLOCKWISE until completely snug. 20 POWERING LUXEPORT WALLSTATION Option 1 | PoE LuxePort WallStation can be powered by any 802.3af PoE Switch. (Sold Separately) Switch Option 2 | Injector LuxePort WallStation can be powered by the iPort PoE Injector. (Sold Separately) Part Number: 70719 21 SINGLE GANG INSTALLATION DETAILS Step 1 Remove 1G box from drywall. Step 2 Run CAT5/6 Cable to power source location. 1 G Box Step 3 Place the metal mounting plate on the wall. Using a pen or pencil, mark the anchor location on each of the four corners of the mounting plate. Step 4 Drive the four provided wall anchors into the wall in the marked locations. 22 23 SINGLE GANG INSTALLATION DETAILS Step 5 Attach black metal mounting plate to the installed anchors using the provided mounting screws. Step 6 Insert the LuxePort Wall Box into the Cover Plate. Step 7 Place both the Wall Box and Cover Plate onto the Mounting Plate and secure using the provided four M4 x 5.5 mm machine screws. Continue to the next page for power information. 24 25 INSTALLING PoE SPLITTER AND WALLSTATION Step 8 Connect the Cat5/6 cable to the RJ45 jack on the splitter. Connect the USB cable to the splitter and the other end to the WallStation. Place the Splitter into the Wall Box. Step 9 Place WallStation against wall. Orient Charge Pins downward. Use the provided lock tool to attach the WallStation to the Wall Box and secure all four mounting screws making sure to turn COUNTER CLOCKWISE until completely snug. 26 POWERING LUXEPORT WALLSTATION Option 1 | PoE LuxePort WallStation can be powered by any 802.3af PoE Switch. (Sold Separately) Switch Option 2 | Injector LuxePort WallStation can be powered by the iPort PoE Injector. (Sold Separately) Part Number: 70719 27 UPGRADING LAUNCHPORT TO LUXEPORT Step 1 Remove LaunchPort Cover Plate and unscrew LaunchPort WallStation. Step 2 Leave existing drywall anchors installed. Remove WallStation and secure 2 conductor wire from falling into the wall. Remove old green connector using a 1.5 mm slotted screw driver. 28 29 LAUNCHPORT UPGRADE OPTION 1 | 24V 110/220V Input 24V 1A Output Using existing 2-wire used by LaunchPort to power a 24V LuxePort WallStation: 1A Source a 24V 1A DC power supply (not provided). Connect the Power Supply to the receptacle and the cable to the existing LaunchPort Power Wall Plate. DC Connector: 2.5mm x 5.5mm Terminate the 2-wire into the Blue 2-pin connector on the PoE Splitter using a precision slotted screwdriver. LAUNCHPORT UPGRADE POWER OPTION 2 | PoE LuxePort can be powered by any 802.3af PoE Switch or iPort PoE injector (sold separately). iPort PoE Injector PN: 70719 Run new CAT 5/6 cable to power the LuxePort WallStation. Connect the CAT 5/6 cable into the RJ-45 Jack on the PoE Splitter. 30 31 UPGRADING LAUNCHPORT TO LUXEPORT Step 3 Attach black metal mounting plate to the installed anchors. Step 4 Insert the LuxePort Wall Box into the Cover Plate. Step 5 Place both the Wall Box and Cover Plate onto the Mounting Plate and secure using provided four M4 x 5.5 mm machine screws. 32 33 INSTALLING PoE SPLITTER AND WALLSTATION Step 6 Connect the 2 conductor wire to the blue 2 pin connector (fig. 1) or connect the CAT5/6 cable to the RJ45 Jack (fig. 2) on the splitter. Connect the USB cable to the Splitter and the other end to the WallStation. Place the Splitter into the Wall Box. Figure 1 24V Power Option Figure 2 PoE Option 34 35 Step 7 Place WallStation against wall. Orient Charge Pins downward. Use the provided lock tool to attach the WallStation to the Wall Box and secure all four mounting screws making sure to turn COUNTER CLOCKWISE until completely snug. 36 ATTACHING LUXEPORT CASE TO WALLSTATION Place the Case in Portrait or Landscape. Align the square recess of the case with the WallStation and ensure the Case is properly seated for secure mounting and charging. Case can be charged in portrait or landscape on both the WallStation and BaseStation. Dismount Case by pulling from left or right side. 37 For more help and info please visit: iportproducts.com/luxeport iPort 991 Calle Amanacer San Clemente, CA 92673 United States of America +1 949 226 5222 CAUTION: This product contains magnets. Do not place in direct proximity with magnetically sensitive objects such as credit cards or exposed hard drives. Persons with pace makers are not recommended to use this product. CAUTION: Use products as directed. Unspecified use could result in injury. Warranty can be found at iportproducts.com/warranty 33-7885Adobe PDF Library 15.0 Adobe InDesign CC 13.0 (Macintosh)