Instruction Manual for comelit models including: CA2100A, CA2200, CA2200 Ciao Outdoor Entrance Panel, Ciao Outdoor Entrance Panel, Outdoor Entrance Panel, Entrance Panel, Panel

Art. CA2100A, CA2200

CA2100A, CA2200 - Technical manual Technical manual 4.6 MB

CA2100A - Comelitgroup


File Info : application/pdf, 16 Pages, 4.60MB

PDF preview unavailable. Download the PDF instead.

mt-ca2100a-ca2200-en
EN
TECHNICAL MANUAL

Ciao outdoor entrance panel Art. CA2100A - CA2200

Passion.Technology.Design.

Warning
· This Comelit product has been designed and manufactured for use in the creation of audio and video communication systems in residential, commercial, industrial and public buildings.
· All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
· Disconnect the power supply before carrying out any operations on the wiring. · Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system
manual. · We advise against running the system wires through the same duct as power cables (230V or higher). · To ensure Comelit products are used safely:
· carefully observe the indications provided in the Manuals / Instruction sheets, · make sure the system created using Comelit products has not been tampered with / damaged. · Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the Manuals / Instruction sheets. · Any repairs must be carried out: · for the products themselves, exclusively by Comelit Group S.p.A., · for the systems, by qualified technical personnel. · Comelit Group S.p.A. accepts no liability for: · any purpose other than the intended use, · failure to observe the indications and warnings contained in this Manual / Instruction sheet. · Comelit Group S.p.A. reserves the right to change the information provided in this Manual / Instruction Sheet at any time and without prior notice.
Table of contents
Description....................................................................................... 3 Art. CA2100A.............................................................................................3 Art. CA2200 ...............................................................................................4
Technical specifications ................................................................. 4 Art. CA2100A.............................................................................................4 Art. CA2200 ...............................................................................................5
Installing entrance panel art. CA2100A ......................................... 6 Changing nameplates ..................................................................... 6 Installing entrance panel art. CA2100A with button module art. CA2200 ............................................................................................. 7 Connections..................................................................................... 9
Variants .....................................................................................................9 Programming call addresses other than the pre-programmed options............................................................................................ 10 Smart programming of consecutive addresses ......................... 10 Programming of specific addresses............................................ 11 Special programmes ..................................................................... 13 Operating notes ............................................................................. 14 System performance and layouts ................................................ 14 Addressing table............................................................................ 15
2

Description
Ciao series outdoor audio entrance panel for Simplebus2 system, designed for systems from 1 to 8 calls. · Technopolymer front cover offering resistance to atmospheric agents (protection rating IP54 and coating with anti-UV
treatment) and acts of vandalism (protection rating IK08). · Smart button programming function. · Surface-mount installation support included. · Buttons for configurations with 1, 2, 4 or 8 calls available to purchase separately.

Art. CA2100A

art. CA9213
9.
1

1.
art. CA9210

2.

1

2

3.

art. CA9211

1 2 3 4

NO NC
JP1

SE
-

SE NC NO +

C

8.

art. CA9212

4.

1

5

2

6

3

7

4

8

NO NC

7.

JP1

SE
-

SE NC NO +

C

10.
11. 12. 13. 14.
15.

6.
5. 2.

14.

18. 17. 16.

1. Technopolymer cover
2. Faceplate fixing screw holes
3. Loudspeaker
4. Call buttons 1 / 2 / 4 / 8 users (available to purchase separately)
5. Microphone
6. Condensation drainage hole
7. CV2 jumper to be removed when switching off the button lighting
8. JP1 enabling the RC network for door lock filter on relay contacts
9. Terminal block for J4connection: SE- SE+ connection for electric door lock NC NO C relay contacts
10. Terminal block for J3connection: L L bus line connection COM RTE and DO reference negative DO door open indication RTE request to exit button

11. LED button brightness control trimmer 12. S2 DIP-switches for button addressing and special
function programming 13. S1 DIP-switches for button type configuration (1 / 2 / 4
/ 8 users) 14. J2 and J5 6-pole connectors for button module
connection 15. SPK loudspeaker volume adjustment trimmer 16. SW1 programming confirmation button 17. PRC call address programming input/output switch 18. PRS special programming input/output switch
3

Art. CA2200

art. CA9213

1. art. CA9210

2.

3. 4.
art. CA9211

art. CA9212

1. Call buttons 1 / 2 / 4 / 8 users (available to purchase separately)
2. TM1 button brightness control/switch-off trimmer
3. S1 dip switch for button type configuration (1 / 2 / 4 / 8 users) and button module addressing
4. J1 and J2 6-pole connectors for connection of art. CA2100A / CA2200

Technical specifications

Art. CA2100A

GENERAL DATA
Type Height (mm) Width (mm) Depth (mm) Product colour Coating material type Surface mounting
COMPATIBLE SYSTEMS
Simplebus2 audio with power supply unit art. 1210/1210A
AUDIO SPECIFICATIONS
Microphone Loudspeaker

Monolithic 172 100 28 Grey RAL 9006 Technopolymers Yes
4 (ø), omnidirectional 50 mm (Ø), 8 Ohm, 0.2W

4

ELECTRICAL SPECIFICATIONS
Type of power supply Power supply voltage Absorption in standby (W) Maximum absorption (W)

Power supply via video entry bus 33 VDC 1.7 7.6

HARDWARE CHARACTERISTICS
Call type Type of buttons Number of buttons (no.) Backlighting colour Terminals Removable terminals Number of inputs (no.) Number of outputs (no.)

Buttons Mechanical 8 White L L COM DO RTE C NO NC SE+ SE Yes 2 1

SETTINGS

Backlighting brightness

Yes

Loudspeaker volume

Yes

ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS

IP protection rating IK anti-vandal protection rating Operating temperature (°C) Operating humidity (max RH - %) Environmental class CE certification

IP54 IK08 -25 to 55 20 to 95 IV RoHS II - 2011/65/EU (EN 50581:2012), EMC 2014/30/EU (EN 61000-6-1:2007, EN 61000-6-3:2007+A1:2011)

Art. CA2200

GENERAL DATA Type Height (mm) Width (mm) Depth (mm) Product colour Surface mounting

Monolithic 172 100 28 Grey RAL 9006 Yes

COMPATIBLE SYSTEMS Simplebus2 audio with power supply unit art. 1210/1210A

ELECTRICAL SPECIFICATIONS
Type of power supply Power supply voltage Absorption in standby Maximum absorption (W)

Power supply via video entry bus 33 VDC 0.62 0.62

HARDWARE CHARACTERISTICS
Call type Type of buttons Number of buttons (no.) Backlighting colour

Buttons Mechanical 16 White

SETTINGS

Backlighting brightness

Yes

ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS

IP protection rating IK anti-vandal protection rating Operating temperature (°C) Operating humidity (max RH - %) Environmental class CE certification

IP54 IK08 -25 to 55 25 to 95 IV RoHS II - 2011/65/EU (EN 50581:2012), EMC 2014/30/EU (EN 61000-6-1:2007, EN 61000-6-3:2007+A1:2011)

5

Installing entrance panel art. CA2100A

2

1

3

1

2

f Set the S1 DIP-switches according to the number of buttons.

S1
3

S1 CA9213
ON
12 (Default)
S1 CA9211
ON
12

S1 CA9210
ON

1

1

12

2

S1 CA9212

1

ON

2

3

12

4

1

5

2

6

3

7

4

8

4

5

6

7

Changing nameplates

1 2

1

2

3

6

Installing entrance panel art. CA2100A with button module art. CA2200

100 mm

28 mm

2

1

3

172 mm

1

f Set the S1 DIP-switches according to the number of buttons.

art. CA9213 ON

56 art. CA9210
ON
56 art. CA9211
ON

DIP 5-6
S1

56
art. CA9212 ON

56
2

1 3A
1 3B

2 3

2

3

7

The addressing of button modules allows, if a module art. CA2200 is replaced, just the address of the replaced module art. CA2200 to be programmed, without having to reprogram all the buttons.

1

1111 12

123
MAX 4 modules
1234

222
33
4
MAX 4 modules

4

ON
1
123456
S1

ON

2

S1

123456

S1

ON
3
123456
S1

ON
4
123456
S1

2 1

5

6

7

CA2100A

8

CA2200

9

10

8

Connections

1209 1210 1210A

SE
-

SE +

NC

NO

C

R T E

DC

O

O M

L

L

J5
CA2100A +CA921x

M4 mAXod4ulmesodmualxi .((7722 uutseenrsti)) cwoitnh1a2rt1. 01/211201/102A10A

J2

J1

CA2200 +CA921

Max 20 m. Local door-opener button. Max 20 m. Active input closed for DOOR OPEN signal.

Variants
VVaarriiaannttefopreursli'nugtiltihzezoexdteelrrnealèl udneilt preolsatyo esterno

230 V

12V/24V AC-DC
10A MAX

SE
-

SE +

NC

NO

C

R T E

D O

C O M

L

L

CA2100A +CA921x

VVaarriaiannttfeopr eursli'nugtilaizszaofedtiyudnoaosrelrorcaktura di sicurezza
12/24V AC/DC

SE
-

SE +

NC

NO

C

R T E

D O

C O M

L

L

CA2100A +CA921x

"CA.tNtCiv.aNzOiorneleayrealcètivCa.tNioCn.NonOasctuuator ccoommanadndo: a2tstueca.tore: 2 sec"
SSeetttDarIPe-iswdiitpchinesminopdeormpaenrmenat nmeondteeas csohmowendinaffiigguurera

JJPP11eanbailbitlainzgiotnheerReCtenReCtwpoerrkfiflotrrodsoeorrralotucrkafisltueircoonntraetltaiydceol nretalècts

JP1

NO NC
JP1

SE
-

SE +

NC

NO

C

NO NC
JP1

SE
-

SE +

NC

NO

C

NO NC
JP1

SE
-

SE +

NC

NO

C

SOuni cCo. nNtOa.ttcioCn.taNcOts.

SuOi ncoCn. tNaCtt.i cCo.nNtaCct.s

Excluded: voltage-free
Esccluosnata: cctontatto pulito

9

Programming call addresses other than the pre-programmed options
There are 2 programming methods: · Smart programming of consecutive addresses: allows quick programming of buttons with consecutive addresses (e.g.:
5, 6, 7, 8) · Programming of specific addresses: allows programming of specific addresses (e.g.: 25, 37, 70, 58)
Smart programming of consecutive addresses
The programming procedures must be carried out in the specified order

1
S1
3

Take note of the S2 DIP-switch

settings

2

ON

Art. CA9213

12

S1

ON

Art. CA9210

12

S1

ON

Art. CA9211

12

S1

ON

Art. CA9212

f Set S1 according to the number of buttons

12

S1

4

LL
f Connect the entrance panel
f Enter programming mode by moving PRC upwards

example code 5

f Set the address of the apartment you wish to call

(for example: 5) using the DIP-switches (see table,

5

page 15)

6

10

=5
f Press the button you want to associate with the call address set using the DIPswitches

+1 = 6

+1 = 7

+1 = 8

7 f Press the following buttons to assign consecutive addresses; every time a button is pressed the address will be increased by 1

f Exit programming

by moving PRC

f Restore the configuration of the DIP-

8

downwards
9

switches for S2

Programming of specific addresses
The programming procedures must be carried out in the specified order

1
S1
3

Take note of the S2 DIP-switch settings
2

ON

Art. CA9213

12

S1

ON

Art. CA9210

12

S1

ON

Art. CA9211

12

S1

ON

Art. CA9212

f Set S1 according to the number of buttons

12

S1

4

LL
f Connect the entrance panel
f Enter programming mode by moving PRC upwards
11

example code 25

f Set the address of the apartment you wish to call

(for example: 25) using the DIP-switches (see table,

5

page 15)

6

example code 37

example code 70

= 25
f Press the button you want to associate with the call address set using the DIPswitches
example code 58

= 37

= 70

7 f Repeat steps 4 and 5 to assign a specific address to each button

= 58

f Exit programming

by moving PRC

f Restore the configuration of the

8

downwards

9

DIP-switches for S2

12

Special programmes

LL
esEexmamppiole codcicoede220088

1

2

3

Depending on the function you want to program, set the DIP-switches in accordance with the table below.

2

1

4

5

Repeat steps 3 and 4 to program other special functions

CODE
195 196 197 198 199 206 207 211 215 216 217 218 219 220 221 222
202
203
214
227 228

DIP SWITCHES ON FUNCTIONS

Audio messages

1,2,7,8

Hebrew

3,7,8

Polish

1,3,7,8

Catalan

2,3,7,8

Galician

1,2,3,7,8

Basque

2,3,4,7,8

Danish

1,2,3,4,7,8

Norwegian

1,2,5,7,8

Swedish

1,2,3,5,7,8

Italian

4,5,7,8

French

1,4,5,7,8

Spanish

2,4,5,7,8

Dutch

1,2,4,5,7,8

Greek

3,4,5,7,8

English

1,3,4,5,7,8

German

2,3,4,5,7,8

Portuguese

2,4,7,8 1,2,4,7,8 2,3,5,7,8

Enables voice message (door opened warning) when the RTE contact is closed Disables voice message (door opened warning) when the RTE contact is closed (default setting) OFF (default)

1,2,6,7,8 3,6,7,8

Actuator control management. N.B. the system should not include art. 1256 in generic actuator mode. Actuator function on S serial line = enabled Actuator function on S serial line = disabled (default)
13

229

1,3,6,7,8

C.NC.NO relay activation on actuator command: 2 sec

230

2,3,6,7,8

C.NC.NO relay activation on actuator command: 4 sec

231

1,2,3,6,7,8

C.NC.NO relay activation on actuator command: 8 sec

Door lock

245

1,3,5,6,7,8

Door lock time: 2 sec. + disabling tone (default)

246

2,3,5,6,7,8

Door lock time: 4 sec

247

1,2,3,5,6,7,8 Door lock time: 8 sec

248

4,5,6,7,8

Door lock confirmation tone: enabled

251

1,2,4,5,6,7,8 Relay C.NC.NO in parallel to SE (default)

252

3,4,5,6,7.8

Lock-release always enabled (default)

253

1,3,4,5,6,7,8 Lock-release only enabled for user called

System functions

232

4,6,7,8

Awaiting response time: 60 sec. (default)

233

1,4,6,7,8

Awaiting response time: 120 sec

234

2,4,6,7,8

Awaiting response time: 30 sec

235

1,2,4,6,7,8

Talk time: 90 sec. (default)

236

3,4,6,7,8

Talk time: 180 sec

239

1,2,3,4,6,7,8 Confirmation tone on user call = enabled (default)

240

5,6,7,8

Confirmation tone on user call = disabled

243

1,2,5,6,7,8

Reset wait time: 10 sec (default)

244

3,5,6,7,8

Reset wait time: 1 sec

208

5,7,8

Enables "awaiting reset time" on lock-release command.

209

1,5,7,8

Disables "awaiting reset time" on lock-release command (awaiting response time or talk time will be activated)

249

1,4,5,6,7,8

Send call: single (default)

250

2,4,5,6,7,8

Call transmission: triple

System mode

0

Simplebus (default)

255

1,2,3,4,5,6,7,8 Simplebus Top

254

2,3,4,5,6,7,8 Restore default

Operating notes
When a call is transmitted from the external unit, if a busy tone is heard instead of the ringtone, this means communication with another external unit is in progress.
System performance and layouts
For further information of system performance and to view installation layouts, click on the system type that best meets your requirements: · Audio kit for the creation of audio systems for detached homes · SB2 audio system kit for the creation of audio systems for residential complexes

14

Addressing table

Code

Dip switch ON

1

1

31 1,2,3,4,5

2

2

32

6

3

1.2

33

1,6

4

3

34

2.6

5

1,3

35

1,2,6

6

2,3

36

3,6

7

1,2,3

37

1,3,6

8

4

38

2,3,6

9

1,4

39 1,2,3,6

10

2,4

40

4,6

11 1,2,4

41

1,4,6

12

3,4

42

2,4,6

13 1,3,4

43 1,2,4,6

14 2,3,4

44

3,4,6

15 1,2,3,4 45 1,3,4,6

16

5

46 2,3,4,6

17

1,5

47 1,2,3,4,6

18

2,5

48

5.6

19 1,2,5

49

1,5,6

20

3,5

50

2,5,6

21 1,3,5

51 1,2,5,6

22 2,3,5

52

3,5,6

23 1,2,3,5 53 1,3,5,6

24

4.5

54 2,3,5,6

25 1,4,5

55 1,2,3,5,6

26 2,4,5

56

4,5,6

27 1,2,4,5 57 1,4,5,6

28 3,4,5

58 2,4,5,6

29 1,3,4,5 59 1,2,4,5,6

30 2,3,4,5 60 3,4,5,6

61 1,3,4,5,6

91 1,2,4,5,7 121 1,4,5,6,7 151 1,2,3,5,8 181 1,3,5,6,8 211 1,2,5,7,8

62 2,3,4,5,6

92 3,4,5,7

122 2,4,5,6,7 152 4,5,8

182 2,3,5,6,8 212 3,5,7,8

63 1,2,3,4,5,6 93 1,3,4,5,7 123 1,2,4,5,6,7 153 1,4,5,8

183 1,2,3,5,6,8 213 1,3,5,7,8

64

7

94 2,3,4,5,7 124 3,4,5,6,7 154 2,4,5,8

184 4,5,6,8

214 2,3,5,7,8

65

1,7

95 1,2,3,4,5,7 125 1,3,4,5,6,7 155 1,2,4,5,8 185 1,4,5,6,8 215 1,2,3,5,7,8

66

2,7

96

6.7

126 2,3,4,5,6,7 156 3,4,5,8

186 2,4,5,6,8 216 4,5,7,8

67

1,2,7

97

1,6,7

127 1,2,3,4,5,6,7 157 1,3,4,5,8 187 1,2,4,5,6,8 217 1,4,5,7,8

68

3,7

98

2,6,7

128

8

158 2,3,4,5,8 188 3,4,5,6,8 218 2,4,5,7,8

69

1,3,7

99 1,2,6,7

129

1,8

159 1,2,3,4,5,8 189 1,3,4,5,6,8 219 1,2,4,5,7,8

70

2,3,7

100 3,6,7

130

2,8

160

6,8

190 2,3,4,5,6,8 220 3,4,5,7,8

71 1,2,3,7

101 1,3,6,7

131 1,2,8

161 1,6,8

191 1,2,3,4,5,6,8 221 1,3,4,5,7,8

72

4,7

102 2,3,6,7

132

3,8

162 2,6,8

192

7,8

222 2,3,4,5,7,8

73

1,4,7

103 1,2,3,6,7 133 1,3,8

163 1,2,6,8

193 1,7,8

223 1,2,3,4,5,7,8

74

2,4,7

104 4,6,7

134 2,3,8

164 3,6,8

194 2,7,8

224 6,7,8

75 1,2,4,7

105 1,4,6,7

135 1,2,3,8

165 1,3,6,8

195 1,2,7,8

225 1,6,7,8

76

3,4,7

106 2,4,6,7

136

4,8

166 2,3,6,8

196 3,7,8

226 2,6,7,8

77 1,3,4,7

107 1,2,4,6,7 137 1,4,8

167 1,2,3,6,8 197 1,3,7,8

227 1,2,6,7,8

78 2,3,4,7

108 3,4,6,7

138 2,4,8

168 4,6,8

198 2,3,7,8

228 3,6,7,8

79 1,2,3,4,7 109 1,3,4,6,7 139 1,2,4,8

169 1,4,6,8

199 1,2,3,7,8 229 1,3,6,7,8

80

5,7

110 2,3,4,6,7 140 3,4,8

170 2,4,6,8

200 4,7,8

230 2,3,6,7,8

81

1,5,7

111 1,2,3,4,6,7 141 1,3,4,8

171 1,2,4,6,8 201 1,4,7,8

231 1,2,3,6,7,8

82

2,5,7

112 5.67

142 2,3,4,8

172 3,4,6,8

202 2,4,7,8

232 4,6,7,8

83 1,2,5,7

113 1,5,6,7

143 1,2,3,4,8 173 1,3,4,6,8 203 1,2,4,7,8 233 1,4,6,7,8

84

3,5,7

114 2,5,6,7

144

5.8

174 2,3,4,6,8 204 3,4,7,8

234 2,4,6,7,8

85 1,3,5,7

115 1,2,5,6,7 145 1,5,8

175 1,2,3,4,6,8 205 1,3,4,7,8 235 1,2,4,6,7,8

86 2,3,5,7

116 3,5,6,7

146 2,5,8

176 5,6,8

206 2,3,4,7,8 236 3,4,6,7,8

87 1,2,3,5,7 117 1,3,5,6,7 147 1,2,5,8

177 1,5,6,8

207 1,2,3,4,7,8 237 1,3,4,6,7,8

88

4,5,7

118 2,3,5,6,7 148 3,5,8

178 2,5,6,8

208 5,7,8

238 2,3,4,6,7,8

89 1,4,5,7

119 1,2,3,5,6,7 149 1,3,5,8

179 1,2,5,6,8 209 1,5,7,8

239 1,2,3,4,6,7,8

90 2,4,5,7

120 4,5,6,7

150 2,3,5,8

180 3,5,6,8

210 2,5,7,8

*240 5,6,7,8

* NOTE: Code 240 is reserved for the porter switchboard

15

2ª ed. Rev1 01/2025 cod. 2G40002810

www.comelitgroup.com
Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy



References

Adobe PDF Library 17.0 Adobe InDesign 20.0 (Windows)