FS N9550-32D Switch Hardware Guide

About This Guide

This guide provides step-by-step instructions for installing the hardware and performing the initial software configuration of the N9550-32D switch. After completing the installation and basic configuration procedures covered in this guide, you could refer to the PicOS® documentation for information about further software configuration.

1. N9550-32D Overview

1.1 System Overview

The N9550-32D is a next-generation, fixed-configuration spine-and-leaf switch. It supports flexible, cost-effective, high-density 400GbE, 200GbE and 100GbE interfaces for server and intra-fabric connectivity.

The switch offers an advanced L2, L3 feature. For large public cloud providers, the switch supports very large, dense, and fast 400GbE IP fabrics. Delivering 25.6 Tbit/s (bidirectional) of bandwidth, it is optimally designed for spine-and-leaf deployments in enterprise, HPC, service provider, and cloud data centers.

1.1.1 Benefits of the N9550-32D

  • Industry-leading wire speed: N9550-32D switch offers 400-Gbit/s wire speed.
  • Includes advanced PicOS® features: RoCEv2, PFC, ECN, DLB and MLAG.
  • High-performance packet processing and local storage: Powered by Broadcom BCM56980 Tomahawk 3 with 64GB SSD.
  • Support for channelization: Using breakout cables, the 400G port splits into 4x 100G, as well as splitting into 2x 200G, increasing the total number of 100GbE ports per switch to 128 and 200GbE ports per switch to 64.
  • Reduces compute-intensive workloads for hyperscale cloud and high-performance computing (HPC) data centers. Examples of these compute-intensive workloads include AI, machine learning, deep learning applications, and storage disaggregation workloads such as Non-Volatile Express over Fabrics (NVMe over Fabrics).
  • Enables data center re-architecture with flattened pods that slash switch hop latency.
  • Enables a fast response by demanding applications, such as those encountered in financial exchanges by reducing intracluster switch latency.
  • Saves energy costs by highly reducing power consumption per Gbit/s of network traffic passing through the switch.
  • Provides an extensive roadmap to new features and functions, such as:
    • Comprehensive Remote Direct Memory Access over Converged Ethernet version 2 (RoCEv2)
    • Advanced congestion control and flow-aware traffic scheduling
    • Support for container networking and segment routing
    • Scale-out load balancing and multipathing
    • Support for advanced network instrumentation adopted by cloud data centers

1.1.2 System Software and Hardware and Software Features

The N9550-32D switch runs the PicOS® operating system and delivers Layer 2 and Layer 3 switching, routing, and security services. Table 1 lists the hardware and software features supported on the model.

Table 1. Hardware and Software Features Supported on N9550-32D Switch Model

Switch ModelSupported SystemHardware FeaturesAggregate Throughput (Bidirectional)Software Features
N9550-32DPicOS®
  • Broadcom BCM56980 Tomahawk 3 Chip
  • Intel® Xeon® Processor D-1518 4-Core CPU
  • 8GB x 2 SO-DIMM memory
  • 64-GB SSD storage
25.6 Tbit/s
  • Feature-rich automation capabilities with support for Python, Ansible, and zero-touch provisioning (ZTP)
  • Advanced PicOS® features such as RoCEv2, PFC, ECN, DLB and MLAG.

1.1.3 Channelization in N9550-32D

N9550-32D switch supports channelization. You can channelize the 400GbE quad small form-factor pluggable double density (QSFP-DD) ports into interfaces by connecting breakout cables and by using CLI configuration. Table 2 lists the channelization supported on the model.

Table 2. Channelization in N9550-32D

Switch ModelPortsPort SpeedSupported Channelization
N9550-32D1-32400GbE4x 100GbE Interfaces
2x 200GbE Interfaces
1-32200GbE *4x 50GbE Interfaces *
1-32100GbE4x 25GbE Interfaces *
33-3410GbE *-

Notice: *Expected to be available in Q3 2025

1.1.4 Components on the Front and Rear Panels

?️ Figure 1: N9550-32D—Front View

?️ Figure 2: N9550-32D—Rear View

?️ Figure 3: Components on the Front and Rear Panel of N9550-32D. This figure illustrates the front panel with numbered ports: 1 (32x 400G QSFP-DD), 2 (ToD Port), 3 (MGMT), 4 (Console), 5 (USB), 6 (2x 10G SFP+). The rear panel shows: 1 (1+1 Hot-swappable Power Supplies), 2 (5+1 Hot-swappable Smart Fans).

1.2 Chassis

1.2.1 Chassis Physical Specifications

The N9550-32D switch is a rigid sheet-metal structure that houses all components of the switch. Table 3 shows the physical specifications of the N9550-32D switch model.

Table 3. Physical Specifications of the N9550-32D Switch Model

ModelHeightWidthDepthWeight
N9550-32D1.69" (4.3cm)17.25" (43.8cm)21.1" (53.6cm) excluding fan and power supply handles28.2 lbs (12.8kg) two power supplies and fans installed

1.2.2 Field-Replaceable Units

Field-replaceable units (FRUs) are components that you can replace at your site. The FRUs in N9550-32D switch are hot-removable and hot-insertable: You can remove and replace them without powering off the switch or disrupting switch functions. The N9550-32D switch has the following FRUs:

  • Power supplies
  • Fan modules
  • Transceivers

ℹ️ Note: Transceivers are not part of the shipping configuration. If you want to purchase any of these components, you must order them separately.

1.2.3 Chassis Status LEDs

The front panel of the N9550-32D switch features four chassis status LEDs labeled Diagnosis, PS1, PS2 and FAN (see ?️ Figure 4).

Table 4 describes the chassis LEDs on the N9550-32D switch, its color and states, and the states they indicate.

?️ Figure 4: Chassis status LEDs.

Table 4. Chassis ID LED on a N9550-32D Switch

LED LabelColorState and Description
DiagSolid GreenAll OK, CLI prompt available.
Blinking GreenBoot-up in progress.
Solid AmberSystem self-diagnostic test has detected a fault (Fan, thermal or any interface fault.).
FANSolid GreenSystem FAN operates normally.
Solid AmberFan tray present but system FAN is fault.
OFFSystem OFF.
PS1Solid GreenThis power is operating normally.
Solid AmberPWR present but not power on or this power is fault.
OFFPower supply is not present.
PS2Solid GreenThis power is operating normally.
Solid AmberPWR present but not power on or this power is fault.
OFFPower supply is not present.

1.2.4 LEDs on the Management Port

The N9550-32D switch has a RJ-45 management port on the front panel. The figure below shows the location of the management port on the N9550-32D and the LED on the port (see ?️ Figure 4). The LED indicates link activity of the port.

Table 5 describes the LED on the management port on N9550-32D switch.

?️ Figure 5: LED on the Management port.

Table 5. LED on the Management Port on N9550-32D

LED LabelColorState and Description
RJ45 10/100/1000Base-T Management PortOffNo Link.
On/Flashing GreenIt has a valid link. Flashing indicates activity.

1.2.5 Network Port LEDs

Each QSFP-DD port on N9550-32D switch has four LEDs that show the link activity of the port (see ?️ Figure 6).

See Table 6 to learn more about those LEDs.

?️ Figure 6: LEDs on the QSFP-DD ports.

Table 6. LEDs on the QSFP-DD Ports on N9550-32D Switch

ColorState and Description
QSFP-DD (400G)Only the 1st LED is used when running at 400G without breakout.
Solid BluePort linked operating at max port speed 400G.
OffNo link.
Flashing BlueTransmit/Receive is activity.
QSFP-DD (100G)Only the 1st LED is used when running at 100G without breakout.
Solid GreenPort linked operating at max port speed 100G.
OffNo link.
Flashing GreenTransmit/Receive is activity.
QSFP-DD (4x 100G Breakout)All four LEDs are used when running at 4 x 100G in breakout mode.
Solid GreenPort linked operating at max port speed 100G.
OffNo link.
Flashing GreenTransmit/Receive is activity.
QSFP-DD (2x 200G Breakout)Three LEDs are used when running at 2 x 200G in breakout mode.
Solid Blue (one LED)Port linked operating at max port speed 200G.
Solid Green (two LEDs)Port linked operating at max port speed 200G.
OffNo link.
Flashing GreenTransmit/Receive is activity.

1.3 Cooling System

The cooling system in N9550-32D switches consists of fan modules and built-in fans in the power supplies. The airflow direction depends on the fan modules and power supplies installed in the switch. You can order a N9550-32D switch that supports front-to-back airflow (air enters through the front of the switch).

The fan modules are hot-removable and hot-insertable field-replaceable units (FRUs) installed in the rear panel of the switch: You can remove and replace them without powering off the switch or disrupting switch functions.

1.3.1 Fan Modules

We ship N9550-32D switches with six fan modules (5+1 redundancy) preinstalled in the rear panel.

The fan module is available in one airflow direction: Front-to-back (cold air enters through the front of the switch and hot air exhausts through the back of the switch).

1.3.2 Models and Airflow Direction

Table 7 shows the airflow direction in the N9550-32D switch model.

Table 7. Airflow Direction in N9550-32D Switch Model

Fan Modules and Power SuppliesDirection of Airflow in the Fan Modules and Power Supplies
We ship the switch with six fan modules (with front-to-back airflow) and two AC power supplies (with a red ejector lever).Front-to-back—Cold air intake to cool the chassis is through the vents on the front panel of the chassis, and hot air exhausts through the vents on the rear panel of the chassis.

N9550-32D Model with Front-to-Back Airflow

In the N9550-32D switch models that have front-to-back airflow, the cold air intake to cool the chassis is through the vents on the front panel of the switch and hot air exhausts through the vents on the rear panel (see ?️ Figure 7).

?️ Figure 7: Model with front-to-back airflow. This diagram illustrates airflow entering the front of the switch and exiting the rear, indicating a front-to-back cooling path.

1.3.3 How to Position the Switch

In front-to-back airflow, hot air exhausts through the vents on the rear panel of the switch.

For front-to-back airflow, install the fan modules with the air intake side (typically the side with the fan blades visible or the grille pattern) facing the cold aisle, and the air exhaust side (typically the side with the power connector or handle) facing the hot aisle.

1.3.4 N9550-32D Fan Module Status

There is a status LED for each fan module on N9550-32D switch, next to the fan module slot on the rear panel of the chassis, indicating the status of the fan module. Table 8 describes the fan module LED.

Table 8. Fan Module Status LED

LEDColorDescription
Fan status LEDGreenThe fan module is operating normally.
RedThe fan module is operating abnormally.

1.4 Power System

The smart power module for the N9550-32D supports power consumption management and hot swapping. It can obtain the output power, output current, and operating temperature in real time.

⚠️ Caution:

1.4.1 AC Power Supply in N9550-32D Switch

You can install up to two power supplies in the power supply slots in the rear panel of the N9550-32D switch chassis. On the N9550-32D switch, the slots are labeled PSU1 and PSU2.

?️ Figure 9: AC Power Supply for N9550-32D switch. This figure shows a single AC power supply unit with numbered components: 1 (Handle), 2 (Fan), 3 (Power connector), 4 (LED), 5 (Latch).

Table 9. Components of AC Power Supply

No.ComponentDescription
1HandleHandle of the power module
2FanForward fan
3Power connectorThree-pin connector
4LEDPower status LED
5LatchLatch of the power module

1.4.2 AC Power Supply Specifications

N9550-32D switch supports 1300W AC power supplies. We ship the N9550-32D switch model with two AC power supplies preinstalled in the rear panel of the chassis. You can install it without powering off the switch or disrupting the switching function. Table 10 shows the power supply specifications for AC power supplies for N9550-32D switch.

Table 10. Technical Specifications for AC Power Supplies

ItemSpecification
Dimensions (W x D x H)50.5mm x 321mm x 40mm (1.99 in. x 12.64 in. x 1.57 in.)
Input voltage100-240VAC @1000W
110-240VAC @1100W
200-240VAC @1300W
Input frequency47-63Hz
Input current12A/90-240VAC
7.5A/200-240VAC
Inrush current60A max. at 240VAC
Power factor0.95 at 115VAC/60Hz
0.95 at 230VAC/50Hz
Earth leakage current1.75mA max. at 240VAC
Hot swappingSupported
CoolingFront-to-rear airflow (air exhaust on power module panel)
Overvoltage protectionSupported
Overcurrent protectionSupported
Over-temperature protectionSupported

1.4.3 Power Cord Specifications

A detachable AC power cord is supplied with the AC power supplies. The plug end of the power cord fits into the power source outlet that is standard for your geographical location.

Table 11 shows the specifications of the AC power cord.

Table 11. Specifications of the AC Power Cord

CountriesPower Cord StandardMale PlugFemale ConnectorVoltage CompatibilityMaximum Input Amps
United States, Canada, Mexico, Puerto Rico, Guam, Japan, Virgin Islands (U.S.)USNEMA 5-15PIEC60320 C13100-250VAC10A
United Kingdom, Hong Kong, Singapore, Malaysia, Maldives, Qatar, IndiaUKBS1363IEC60320 C13100-250VAC10A
Continental Europe, South Africa, Switzerland, Italy, IndonesiaEUCEE 7IEC60320 C13100-250VAC10A
China, Australia, New Zealand, ArgentinaCNGB16AIEC60320 C13100-250VAC10A

1.4.4 LEDs on the AC Power Supplies

Table 12 describes the LED on the AC power supply for the N9550-32D switch.

Table 12. LED on the AC Power Supply for N9550-32D

LEDColorDescription
Power status LEDGreenThe power module is operating normally.
RedThe power module is operating abnormally.

2. Site Planning, Preparation, and Specifications

2.1 Site Guidelines and Requirements

The equipment must be installed indoors for normal operation and prolonged service life. The following sections provide specific information to help you plan for a proper operating environment.

2.1.1 Floor Loading

  • Ensure that the floor under the rack supporting the chassis is capable of supporting the combined weight of the rack and all the other components.

2.1.2 Airflow

  • To ensure adequate airflow through the chassis, maintain a minimum clearance of 20 cm (7.87 in.) around air vents. Route the cables and power cords through the cable management brackets to avoid blocking air intake vents. Dust the equipment every three months to prevent blocking the ventilation openings on the housing.

2.1.3 Space

  • You are advised to have a pathway of 0.8 meters (2.62 ft.) wide in the equipment room. This space ensures that you can remove the components and perform routing maintenance easily.
  • The front and rear of the chassis must remain unobstructed to ensure adequate airflow and prevent overheating inside the chassis.

2.1.4 Temperature

To ensure normal operation and prolonged service life of the equipment, maintain an appropriate temperature in the equipment room. Otherwise, the equipment may be damaged.

  • A high temperature can accelerate the aging process of insulation materials, greatly reducing the availability of the equipment and severely affecting its service life.

For the device's operating temperature requirements, please refer to the product datasheet.

ℹ️ Note: The operating temperature is measured at a point that is 1.5 m (4.92 ft.) above the floor and 0.4m (1.31 ft.) before the equipment with no protective plates in front or at the back of the equipment.

2.1.5 Humidity

To ensure normal operation and prolonged service life of the equipment, maintain an appropriate humidity in the equipment room. Otherwise, the equipment may be damaged.

  • In an environment with a high relative humidity, the insulating material is prone to poor insulation or even electricity leakage.
  • In an environment with a low relative humidity, the insulating strip may dry and shrink, resulting in screw loosening. Furthermore, internal circuits are prone to static electricity.

For the device's operating humidity requirements, please refer to the product datasheet.

ℹ️ Note: The operating humidity is measured at the point that is 1.5 m (4.92 ft.) above the floor and 0.4 m (1.31 ft.) before the equipment with no protective plates in front or at the back of the equipment.

2.1.6 Cleanliness

The indoor dust takes on a positive or negative static electric charge when falling on the switch, causing poor contact of the metallic joint. Such electrostatic adhesion may occur more easily when the relative humidity is low, not only affecting the service life of the switch, but also causing communication faults. The following table lists the requirements for the dust and particles in the equipment room:

Table 13. Dust and Particle Requirement

Minimum Dust and Particle DiameterUnitMaximum Quantity
0.5 μmparticles/m³3.5 × 10⁵
5 μmparticles/m³3.0 × 10³

Apart from dust, there are also requirements on the salt, acid, and sulfide in the air of the equipment room. These harmful substances will accelerate metal corrosion and component aging. Therefore, the equipment room should be properly protected against harmful gases, such as sulfur dioxide and hydrogen sulfide. The following table lists limits on harmful gases.

Table 14. Gas Requirement

GasAverageMaximum (mg/m³)
mg/m³cm³/m³mg/m³cm³/m³
Sulfur Dioxide (SO₂)0.30.111.00.37
Hydrogen Sulfide (H₂S)0.10.0710.50.36
Chlorine (Cl₂)0.10.0340.30.1
Nitrogen Oxides (NOₓ)0.50.261.00.52

ℹ️ Note: The average value is measured over one week. The maximum value is the upper limit of the harmful gas measured in one week for up to 30 minutes every day.

2.1.7 System Grounding

A reliable grounding system is the basis for stable and reliable operation, which is indispensable for preventing lightning strikes and interference. Carefully check the grounding conditions at the installation site according to the grounding specifications, and complete grounding properly based on the site situation.

? Grounding: Safety Grounding: Ensure that the rack and power distribution system are securely grounded. Otherwise, electric shocks may occur when the insulation resistance between the power module and the chassis becomes small.

ℹ️ Note: The building should provide a protective ground connection to ensure that the equipment is connected to a protective earth.

? Grounding: Lightning Grounding: The surge protection system is an independent system consisting of a lightning rod, a downlead conductor, and a connector connected to the grounding system. The grounding system is usually used for power reference grounding and safety grounding of the rack.

? Grounding: EMC Grounding: Grounding for the EMC design includes shielded grounding, filter grounding, noise, interference suppression, and level reference.

The grounding resistance should be smaller than 1-ohm. Connect the grounding terminal to the ground before operating the equipment. There is a grounding stud in the lower left corner of the rear panel. They are pasted with a conspicuous label.

2.1.8 Preventing Electromagnetic Interference

Electromagnetic interference mainly comes from outside the equipment or application system and affects the equipment through capacitive coupling, inductive coupling, electromagnetic waves, and other conduction modes.

  • Interference prevention measures should be taken for the power supply system.
  • Keep the equipment far away from the grounding facility and surge protector facility of the power device.
  • Keep the equipment far away from high-frequency current devices such as the high-power radio transmitting station and radar launcher.
  • Take electromagnetic shielding measures when necessary.

2.1.9 Surge Protection

Although the equipment can guard against lightning strikes, strong lightning strikes may still damage the equipment. Take the following surge protection measures:

  • Ensure that the grounding wire of the rack is in good close contact with the ground.
  • Ensure that the neutral point of the AC power socket is in close contact with the ground.
  • You are advised to install a power arrester in front of the power input end to enhance surge protection for the power supply.

2.2 Management Cable Specifications and Pinouts

2.2.1 Console Port Connector Pinout Information

The console port on PicOS® devices is an RS-232 serial interface, using an RJ-45 connector to connect to a console management device. The default baud rate for the console port is 115200 baud.

2.2.1 RJ-45 Management Port Connector Pinout Information

The RJ-45 connector on PicOS® network devices provides the following pinout details for the management port.

Table 15. Pin Signal Definition Table for 1000BASE-T

PinMDI ModeMDI-X Mode
1Media Dependent Interface A+Media Dependent Interface B+
2Media Dependent Interface A-Media Dependent Interface B-
3Media Dependent Interface B+Media Dependent Interface A+
4Media Dependent Interface C+Media Dependent Interface D+
5Media Dependent Interface C-Media Dependent Interface D-
6Media Dependent Interface B-Media Dependent Interface A-
7Media Dependent Interface D+Media Dependent Interface C+
8Media Dependent Interface D-Media Dependent Interface C-

3. Initial Installation and Configuration

3.1 Unpack and Mount the N9550-32D Switch

Below is an optimized guide for unpacking and preparing the N9550-32D switch for installation, including key precautions and potential risk alerts.

3.1.1 Parts Inventory (Packing List) for a N9550-32D Switch

The switch shipment includes a packing list. Check the parts you receive with the switch against the items in the packing list.

Table 16. Inventory of Components Provided with a N9550-32D Switch

ComponentQuantity
AC Power Cord4
Front-Post Bracket2
Rear-Post Bracket2
Screw20
Holder Bracket2
Bracket-Locking Screw2
Console Cable1

3.1.2 Mount the N9550-32D Switch on a Rack

Make sure the previously mentioned "2.1 Site Guidelines and Requirements" have been met before you begin the installation. Plan for the installation site, networking mode, power supply, and cabling in advance. Then, wear an ESD wrist strap, place the switch, and mount it onto the rack.

3.1.2.1 Installation Requirements

Before you begin the installation, make sure that you have the following:

  • Phillips screwdriver.
  • Screws and cage nuts for rack mounting.
  • Standard-sized, 19" wide rack with a minimum of 1U height available.
  • Category 5e or higher RJ-45 Ethernet cables and fiber optical cables for connecting network devices.

3.1.2.2 Installation Guidelines

Please verify that the front and rear brackets of the rack are in the right locations before mounting. If the front brackets are too close to the front door, there will not be sufficient clearance between the front panel and the door. As a result, the front door cannot be closed after Ethernet cables and optical fibers are connected to the chassis. Generally, maintain a minimum clearance of 10mm (0.39 in.) between the front panel and the front door. Before installation, verify the following guidelines are met:

  • The rack has been secured.
  • The various components in the rack have been installed.
  • There are no obstacles inside or around the rack when installing the switch.

3.1.2.3 Mount the Brackets

Secure the front- and rear-post brackets to the two sides of the switch with the supplied screws.

Diagram showing bracket mounting to the switch chassis.

3.1.2.4 Mount the Chassis on the Rack

The chassis can be installed on a standard 19-inch EIA rack. Mount the chassis on the rack with its front panel facing forward. You are advised to use a tray or guide rails to assist in installing the chassis on the rack.

  • Attach the switch to the rack with the rack screws.

3.1.3 Mount the Chassis on the Workbench

If a standard 19-inch EIA rack is not available, mount the switch on a clean workbench.

  • Lay the chassis flat on the workbench and ensure adequate airflow around the chassis.

Diagram showing chassis laid flat on a workbench.

3.2 Connect the N9550-32D to Power

3.2.1 Connect the N9550-32D Switch to Earth Ground

3.2.1.1 Installation Guidelines

A reliable grounding system is the basis for stable and reliable operation, which is indispensable for preventing lightning strikes and interference. The chassis has two grounding studs on its rear panel. Connect the grounding stud to the grounding terminal of the rack and then connect the grounding terminal to the grounding bar of the equipment room.

  • The cross-sectional area of the grounding wire is determined by the maximum possible current. The grounding wire should be of a good conduction quality.
  • Never use bare wires.
  • The combined grounding should have a grounding resistance of less than 1-ohm.
3.2.1.2 Procedure
  • Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.
  • Secure the grounding lug to the grounding point on the switch back panel with the washers and screws.

Diagram showing grounding cable connection to the rear of the switch.

? Danger Warnings:

  • To ensure personal and equipment safety, it is necessary to ground the switch properly. The resistance between the chassis and the ground must be less than 0.1-ohm.
  • The maintenance personnel should check whether the AC power socket is reliably connected to the building's protective ground. If not, the maintenance personnel should use a protective grounding wire to connect the protective ground terminal of the AC power socket to the building's protective ground.
  • The power cord must be plugged into the power socket connected to the earth's ground.
  • The power socket must be installed near the equipment in an easily accessible location.
  • When installing or replacing the unit, the ground connection must always be made first and disconnected last.

3.2.2 Connect Power to N9550-32D Switch

Wear an ESD-preventive wrist strap before proceeding with the following operation.

3.2.2.1 Power Module Installation

  • Remove the power module from its packing materials. Make sure the input indicators meet the requirements.
  • Remove the filler panel from the slot by unscrewing the captive screw. Keep the panel with the nameplate facing upwards. Grasp the handle with one hand and place your other hand underneath the power module to support it. Slide the power module along the guide rails into the slot until the module plugs into the receptacle at the back of the slot.

? Warning:

  • Slide the power module all the way into the chassis gently. Align the power module in the right orientation to the open power slot.
  • If you are not able to push the power module all the way into the slot, carefully slide the module out of the slot, align the module with guide rails, and reinstall the module.
  • All fan and power modules must have the same airflow direction or else an error can occur.

3.2.3 Post-installation Check

ℹ️ Note: Before checking the installation, ensure that all power is turned off and disconnected to prevent personal injury and damage to the switch components.

  • The external power supply matches the power distribution system.
  • The front and rear doors of the rack can close properly after installation has been completed.
  • The rack has been completely fastened, which will not move or tilt.
  • The chassis has been mounted on the rack and all cables have been fastened to the rack.
  • Select the proper fan module and tighten captive screws.
  • Select the proper power module.
  • The power module is completely seated in the slot.
  • At least two personnel are required to power on the chassis. Do not service the chassis before it is powered off.
  • Carefully check your work area for possible hazards, such as ungrounded power extension cables, missing safety grounds, and moist floors.
  • Do not subject the equipment to dampness and avoid liquid inside the equipment.
  • Locate the emergency power-off switch in the room. In the case of an electrical accident, you will be able to quickly turn off the power.
  • Never assume that power is disconnected from a circuit. Instead, always check.
  • The power cord is plugged into the power module and retained there.
  • The power cord is long enough to avoid over-extension.
  • The power socket is connected to the earth ground as required with a rated current of at least 10 A.
  • Each power module receives power from a power socket.
  • If a slot is to remain empty, install a filler panel to allow for adequate airflow and to keep dust out of the chassis.

3.2.4 Connect the Power Cable

  • Plug the AC power cord into the power port on the switch.
  • Connect the other end of the power cord to an AC power source.

⚠️ Caution:

  • Make sure the power socket is OFF before connecting the power cord.
  • Use a 3-core power cord, with a minimum cross-sectional area of 1.5mm² or 14 AWG per pin.
  • Use a 10A power cord for the AC power supply. Adopt the proper power socket and make sure that the AC power system in the equipment room is capable enough.

Diagram showing AC power cable connection to the switch.

3.3 Connect the N9550-32D to the Network

3.3.1 Install a QSFP-DD Transceiver

Before you install a transceiver in a device, ensure that you have taken the necessary precautions for safe handling of lasers. Ensure that you have a rubber safety cap available to cover the transceiver.

The transceivers for FS devices are hot-removable and hot-insertable field-replaceable units (FRUs). You can remove and replace the transceivers without powering off the device or disrupting the device functions.

ℹ️ Note: After you insert a transceiver or after you change the media-type configuration, wait for 6 seconds for the interface to display operational commands.

To install a QSFP-DD transceiver:

  • Wrap and fasten one end of an ESD wrist strap around your bare wrist, and connect the other end of the strap to the ESD point on the switch.
  • Verify that a rubber safety cap covers the QSFP-DD transceiver.
  • Position the transceiver in front of the port on the device so that the QSFP-DD connector faces the port.

3.3.2 Connect a Fiber-Optic Cable

Before you connect a fiber-optic cable to an optical transceiver installed in a device, ensure that you have taken the necessary precautions for safe handling of lasers.

To connect a fiber-optic cable to an optical transceiver installed in a device:

Laser Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cables connected to transceivers emit laser light that can damage your eyes.

  • If the fiber-optic cable connector is covered with a rubber safety cap, remove the cap. Save the cap.
  • Remove the rubber safety cap from the optical transceiver. Save the cap.
  • Insert the cable connector into the optical transceiver.

Diagram showing fiber-optic cable connection to a transceiver.

CAUTION:

  • Do not bend fiber-optic cables beyond their minimum bend radius. An arc smaller than a few inches in diameter can damage the cables and cause problems that are difficult to diagnose.
  • Do not let fiber-optic cables hang free from the connector. Do not allow fastened loops of cables to dangle, which stresses the cables at the fastening point.

3.4 Connect the N9550-32D to External Devices

3.4.1 Connect a Device to a Network for Out-of-Band Management

Ensure that you have an Ethernet cable that has an RJ-45 connector at either end.

You can monitor and manage a network device, such as a router or a switch, by using a dedicated management channel. Each device has a management port to which you can connect an Ethernet cable with an RJ-45 connector. Use the management port to connect the device to the management device.

To connect a device to a network for out-of-band management:

  • Connect one end of the Ethernet cable to the management port on the device.
  • Connect the other end of the Ethernet cable to the management device.

Diagram showing Ethernet cable connection for out-of-band management.

3.4.2 Connect a Device to a Management Console Using an RJ-45 Connector

You can configure and manage your network devices through a dedicated management channel, using the console port available on each device.

3.4.2.1 Console Port Management

Connect the PC to the device's Console port using a console cable, as shown in the image below.

  • Insert the RJ45 connector of the console cable into the RJ45 console port on the switch.
  • Connect the other end of the console cable to the RS-232 serial port on the computer.

Diagram showing console cable connection to a PC.

3.5 Configure PicOS® on the N9550-32D

3.5.1 Default Configuration

We ship each N9550-32D switch programmed with a factory-default configuration that contains the values set for each configuration parameter. The default configuration file sets values for system parameters such as the system log and file messages.

When you commit changes to the configuration, a new configuration file is created that becomes the active configuration. You can always revert to the factory-default configuration.

This topic shows the factory-default configuration file of a N9550-32D switch:

system {
  login {
    announcement: ""
    user operator {
      class: "read-only"
    }
  }
  services {
    ssh {
      port: 22
      root-login: "deny"
      protocol-version: "v2"
      connection-limit: 20
      rate-limit: 20
      disable: false
      idle-timeout: 0
    }
  }
  inband {
    enable: false
  }
  syslog {
    local-file: "ram"
  }
  log-level: "warning"
  log-facility: 0
  timezone: "UTC"
}

3.5.2 Connect and Configure N9550-32D

The initial configuration of the switch requires the user to connect the terminal or computer to the switch's console port. Once the user accesses the switch and establishes the CLI (Command Line Interface) through a serial console connection, an IP address is assigned to the management port, and an IP route to the gateway is created. Keep in mind the following points:

  • The console port provides local serial access to the switch.
  • The Ethernet management port is used for out-of-band network management tasks. Before using the management port for the first time, you must assign an IP address to the port.

3.5.2.1 Connect Console Port

Before configuring the device for the first time, you need to access it via the console port. The console port is located at the front of the switch. You can connect a terminal or a computer to the console port using a serial or RS-232 cable.

Port Settings

Use the following port settings to connect the terminal or computer to the switch console port:

  • Baud rate: 115200
  • Data bits: 8
  • Stop bits: 1

ℹ️ The default width for terminal sessions through the console port is 80 characters. This means that the terminal client's width should be at least 80 characters for proper use of the console port. Most terminal clients have a default width of 80 characters.

3.5.2.2 Assign an IP Address to the Management Interface

Once initial access to the switch is obtained, the user needs to configure the management IP address and default gateway in either L2/L3 mode or OVS mode. This section explains the configuration in L2/L3 mode.

The management IP address is used for maintaining and managing the device. You can configure a static IP address for the management interface eth0, or you can dynamically assign the address via DHCP. If a static IP address is not assigned, the system will default to attempting to obtain the management port IP address dynamically from the DHCP server.

ℹ️ Note: When switching from OVS mode to L2/L3 mode, the static IP address of the management port configured before will still be used if there is no user configuration for it in the new mode.

3.5.2.2.1 Configure Management Interface

Step1 Set static IP addresses for management interface eth0.

set system management-ethernet eth0 ip-address {IPv4 | IPv6} <ip_address>

NOTE: If the static IP address is not assigned, the system will try to dynamically obtain the management port IP address from the DHCP server which is also the factory setting.

Step2 Set the gateway address for management interface eth0.

set system management-ethernet eth0 ip-gateway {IPv4 | IPv6} <ip_address>

Step1 Set static IP addresses for management interface eth0.

admin@Xorplus# set system management-ethernet eth0 ip-address IPv4 192.168.10.5/24

Step2 Set the gateway address for management interface eth0.

admin@Xorplus# set system management-ethernet eth0 ip-gateway IPv4 192.168.10.1

Step3 Commit the configuration.

admin@XorPlus# commit

Step4 Verify the configuration.

Run run show system management-ethernet command to view the configuration information, status and traffic statistics information of the management interface.

admin@XorPlus# run show system management-ethernet

eth0 Hwaddr: 00:18:23:30:e5:72 State: UP

Gateway : 192.168.10.1

Inet addr: 192.168.10.5/24

Traffic statistics

Input Packets......................3620

Input Bytes........................462971

Output Packets.....................597

Output Bytes.......................75459

FS Offices Worldwide:

Delaware, United States

Address: Delaware: 380 Centerpoint Blvd, New Castle, DE 19720, United States

Email: US@fs.com

Tel: +1 (888) 468-9910

California, United States

Address: California: 15241 Don Julian Rd, City of Industry, CA 91745, United States

Email: US@fs.com

Tel: +1 (888) 468-9910

Germany

Address: Röntgenstraße 18, 85757 Karlsfeld, Germany

Email: DE@fs.com

Tel: +49 (0) 8131 377 3008

United Kingdom

Address: Unit 8, Urban Express Park, Union Way, Aston, Birmingham B6 7FH, United Kingdom

Email: UK@fs.com

Tel: +44 (0) 121 726 4775

Australia

Address: 57-59 Edison Rd, Dandenong South, VIC 3175, Australia

Email: AU@fs.com

Tel: +61 3 5909 9990

Singapore

Address: 7002 ANG MO KIO AVENUE 5 #05-02 Singapore 569914

Email: SG@fs.com

Tel: +65 31381992

Japan

Address: JS Progress Building 5F, 4-1-23, Heiwajima, Ota Ku, Tokyo, 143-0006, Japan

Email: JP@fs.com

Tel: +81-3-6897-9438

FS has several offices around the world. Addresses, phone numbers are listed on the FS Website at https://www.fs.com/contact_us.html. FS and FS logo are trademarks or registered trademarks of FS in the U.S. and other countries.

Models: N9550-32D Switch Hardware, N9550-32D, Switch Hardware, Hardware

File Info : application/pdf, 27 Pages, 8.80MB

PDF preview unavailable. Download the PDF instead.

n9550-32d-switch-hardware-guide-20250530154743

References

iText Core 7.2.4 (AGPL version), pdfHTML 4.0.4 (AGPL version) ©2000-2022 iText Group NV; modified using iText Core 7.2.4 (AGPL version) ©2000-2022 iText Group NV; modified using iText Core 7.2.4 (AGPL version) ©2000-2022 iText Group NV

Related Documents

PreviewFS N8550-48B8C Switch Hardware Guide
Comprehensive hardware guide for the FS N8550-48B8C network switch, detailing installation, initial configuration, hardware specifications, and operational requirements for data center deployments.
PreviewFS N8550-24CD8D Switch Hardware Guide
This guide provides step-by-step instructions for installing the hardware and performing the initial software configuration of the FS N8550-24CD8D switch. It covers system overview, chassis specifications, cooling system, power system, site planning, and connection procedures.
PreviewFS N8610-32D Data Center Switch Quick Start Guide
This guide provides essential information for the FS N8610-32D Data Center Switch, covering its introduction, hardware overview, installation requirements, mounting instructions, connection procedures for various ports (SFP+, QSFP-DD, RJ45 Console, MGMT, SFP, USB), power connection, troubleshooting common issues, and product warranty details. It also includes links to online resources and the FS app for further assistance.
PreviewAmpCon-DC Quick Deployment Guide
A comprehensive guide to deploying and managing data center switches using the FS AmpCon-DC automation solution. Learn how to import, deploy, configure, and provision switches for efficient network automation.
PreviewFS N Series Managed Data Center Switches Quick Start Guide
A comprehensive quick start guide for FS N Series Managed L2/L3 Data Center Switches, covering hardware overview, installation, connection, configuration, and troubleshooting for models N5850-48S6Q, N8520-48B6C, N8550-48B8C, N8050-32Q, N8520-32C, and N8550-32C.
PreviewFS S3270-10TM Switch Hardware Guide
Comprehensive hardware guide for the FS S3270-10TM switch, detailing installation, configuration, and operational procedures for optimal network performance.
PreviewFS N8520-32D Data Center Switch Quick Start Guide
This guide provides a quick start for the FS N8520-32D Data Center Switch, covering introduction, accessories, hardware overview, installation requirements, mounting, grounding, connections, and troubleshooting.
PreviewFS S3270-24TM Switch Hardware Guide
This guide provides step-by-step instructions for installing the hardware and performing the initial software configuration of the FS S3270-24TM switch.