00.1 Copertina:00.1 Copertina

michele

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO ...

21 splashproof axial extract fans used to extract air either directly to the outside or into ducting up to 4m long the splashproof vortice punto models are available in the following versions:

Каталог-вентилатори--Punto-M

Битови осеви вентилатори Vortice Punto M | АКВА СИСТЕМИ

20 VORTICE PUNTO RANGE For intermittent or continuous ventilation of bathrooms, toilets, kitchens or utility rooms in domestic or commercial properties. 82 models available with or without the option of automatic

PDF preview unavailable. Download the PDF instead.

Каталог-вентилатори--Punto-M
16_26 PUNTO DEF1 12-11-2008 11:22 Pagina 20
SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG
VORTICE® PUNTO RANGE








 For intermittent or continuous ventilation of bathrooms, toilets, kitchens or utility rooms in domestic or commercial properties.
 82 models available with or without the option of automatic shutters, timer, pull cord, humidistat, electronic microprocessor and Passive infrared.
 Motor with sheilded poles, either with bronze or ball bearings, and with thermal cut-out.
 The standard models can be speed regulated.

 Data and performaces IMQ Performance certified.
 High airflow rate, low operating noise level and low power consumption due to the wing profile blades and motor support.
 IPX4 splashproof protection on all models.
 Motor support and grille made of anti-UV ABS.
 Available in three outlet sizes:  100, 120 and 150 mm.
 Conforms to the following standards: CEI EN 60335-2-80 (Part 2: Particular requirements for fans), CEI EN 60529 (Code IP) and CEI 107-53/1986.
Design: F. Trabucco & Associates
Accessories (description and data on page 25)
Wiring diagrams shown on page XXVII.

 Installation showing extract directly to the outside.  Ceiling installation on up to 4m duct.  Through the wall installation with wall sleeve and grille.  Window installation with standard window kit.

Dimensions (mm)

A

C

B E m3/h l/s mm H2O Pa

M 100/4" M 120/5" M 150/6"

A

B

C

159

160

100

179

181

110

214

215

117

D

D

E

47

99

47

119

47

156

Delivery P max

Product V ~ 50 Hz W A Rpm

Lp dB(A) 3 m

Approvals

kg Insulation IP

°C max

230-240 18 0.1 2300 90 25 3 29

37.5

M 100/4"

230-240 20 0.12 2100 175 48.6 4.5 44

39.5

M 120/5"

230-240 30 0.15 2100 335 93.1 6 59

46

M 150/6"

20

0.6

cl.II X4

50

0.8

cl.II X4

50

1.1

cl.II X4

50

16_26 PUNTO DEF1 12-11-2008 11:22 Pagina 21

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

p p pt

Pressure/performance curves

Pa mmH2O

100

4

30 3

20 2

10 1

00 m3/h 0
l /s 0

25

50

75

100

10

20

qv

Pa mmH2O

120

5

40 4

30 3

20 2

10 1

00 m3/h 0
l/s 0

40 80 120 160 200
10 20 30 40 50 qv

Pa mmH2O

150

8

60 6

40 4

20 2

00 m3/h 0
l/s 0

100 30

200
60 qv

300

400

90

Supply and install a Punto domestic axial extract fan (with or without automatic shutters), for installation in wall, window or ceiling as manufactured exclusively by Vortice only for Vortice. The fan should have a performance in excess of the requirements of the Building Regulations (Document F), even when installed with up to 4 m x (100mm, 120mm and 150mm diameters to suit the three model sizes) of flexible aluminium ducting with 2 number 90 degree bends. The requirements are 15l/s for Bathrooms/Toilets ­ 30 l/s for Utilities and 60 l/s for Kitchens (model with a 15 minute overrun timer for internal rooms). It should be tested and certified as IPX4 (splashproof) with all performance data third party IMQ (BEAB recognised equivalent) verified. The fan should be made from anti-UV ABS plastic and all components and packaging to be 100% recyclable. The internal cover should be of a snap fix design. The motor should be either a bronze bush or a stainless steel ball bearing, shielded pole motor (30,000-hour guarantee), be capable of operating at an ambient temperature up to 50°C and include a thermal cut out device. Control options should include: Speed control (using an optional controller), Pull cord, Timer, PIR (passive Infrared), T-HCS (humidity control system-timer) and MHC (microprocessor humidity control).

THE SPLASHPROOF VORTICE® PUNTO MODELS ARE AVAILABLE IN THE FOLLOWING VERSIONS:

STANDARD LONG LIFE 30.000 h AUTOMATIC

All models are manufactured with shielded poles and have bronze bearings for a long life

All models are manufactured with long-life ball-bearing motors which are guaranteed for 30,000 hours continuous, trouble-free operation.

THE VORTICE® PUNTO MODELS ARE AVAILABLE IN THE FOLLOWING OPTIONS:

The integral shutters positioned behind the front grille automatically open and close slowly when the unit is operated. The shutters are made from shockproof, anti-UV-treated, plastic.

TIMER

TIMER
The timer comes on when the light is

switched on. When the light is turned

off, the unit continues to operate for 3 to 20 minutes, depending on the

timer setting.

T-HCS Humidity Control T-HCS VERSION System - Timer The unit turns on when relative humidity exceeds 65% and it turns
back off when the RH drops back to 65%. When the light is switched off,
the unit will continue to run from between 3 to 20 minutes depending on
the timer setting.

PULLCORD

PULL CORD
The unit is switched on by pulling the
insulated pull cord.

MHC

Microprocessor MHC VERSION
Humidity Control This model has the latest electronic micro-chip technology which provides

high accuracy and continuous monitoring of both temperature and humidity.

Intelligent self-adjusting switch-point which helps eliminate condensation at

source, reduces health hazards and call backs.

PIR

INTEGRAL "PIR" SENSOR
Passive Infrared The unit turns on a few seconds after

the person has entered the room

(sensor is located in an inclined position to increase sensitivity), and

continues to operate during the person's presence. When the person leaves

the room, the unit will continue to run from between 3 to 20 minutes

depending on the timer setting.

12 V Power Supply Unit

12 V MODELS
A power supply unit is needed

wherever the use of low-voltage

equipment is required. The two available low-voltage fans - one with and one

without automatic shutter - can be used in combination with any of the power

supply units.

21

16_26 PUNTO DEF1 12-11-2008 11:22 Pagina 22

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

TYPE OF ROOM
Note: The ceiling kit is to preserve IPX4 integrity

Application

"Wall installation"

"NORMAL OPERATION"

"Ceiling installation (with Kit: 22154/ 22155/22156)"
"Window installation (with Kit: 22131/ 22132/22133)"

Labels to choose

Model

Option

PULLCORD AUTOMATIC
LONG LIFE 30.000 h

 100: BATHROOM, SHOWER,TOILET

"ROOM WITHOUT WINDOW"

"Wall installation"
"Ceiling installation (with Kit: 22154/ 22155/22156)"

TIMER

AUTOMATIC
LONG LIFE 30.000 h

 120: UTILITY ROOM

"CONDENSATION CONTROL"

"Wall installation"
"Ceiling installation (with Kit: 22154/ 22155/22156)"
"Window installation (with Kit: 22131/ 22132/22133)"

T-HCS Humidity Control System - Timer

AUTOMATIC
LONG LIFE 30.000 h

"AUTOMATIC CONDENSATION
CONTROL SYSTEM"

"Wall installation"
"Ceiling installation (with Kit: 22154/ 22155/22156)"
"Window installation (with Kit: 22131/ 22132/22133)"

MHC Microprocessor Humidity Control

AUTOMATIC
LONG LIFE 30.000 h

 150: KITCHEN

PIR FUNCTIONING

"Wall installation"
"Ceiling installation (with Kit: 22154/ 22155/22156)"
"Window installation (with Kit: 22131/ 22132/22133)"

PIR Passive Infrared

AUTOMATIC
LONG LIFE 30.000 h

VORTICE® PUNTO ACCESSORIES

Model

Code Suitable for use with

Fixed grille
C 1.5 electronic speed controller SCNRB recessed electronic speed controller
Window kit
Ceiling kit

22010
22020
12966
12971 22131 22132 22133 22154 22155 22156

11221 - 11231 - 11611 - 11646 - 11222 - 11232 - 11637 - 11684 - And for all products  10 11321 - 11331 - 11721 - 11746 - 11421 - 11431 - 11808 - 11856 - 11332 - And for all products  12/15 11737 - 11747 - 11784 - 11422 - 11432 - 11837 - 11857 - 11884
11201 - 11202 - 11301 - 11302 - 11401 - 11402
11201 - 11202 - 11301 - 11302 - 11401 - 11402
11221 - 11231 - 11611 - 11646 - 11222 - 11232 - 11637 - 11684 11321 - 11331 - 11721 - 11746 - 11322 - 11332 - 11737 - 11747 - 11784 11421 - 11431 - 11808 - 11856 - 11442 - 11432 - 11837 - 11857 - 11884 11201 - 11211 - 11601 - 11681 - 11221 - 11231 - 11611 - 11202 - 11212 - 11682 - 11222 - 11232 - 11637 - 11684 11301 - 11311 - 11701 - 11781 - 11321 - 11331 - 11721 - 11302 - 11312 - 11782 - 11322 - 11332 - 11737 - 11784 11401 - 11411 - 11801 - 11881 - 11421 - 11431 - 11808 - 11402 - 11412 - 11882 - 11422 - 11432 - 11837 - 11884

22

16_26 PUNTO DEF1 12-11-2008 11:22 Pagina 23
SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

11201 11641 11211 11681 11626** 11221 11646 11231 11683**

M 100/4" M 100/4" P M 100/4" T M 100/4" PIR M 100/4" MHC M 100/4" A M 100/4" AP M 100/4" AT M 100/4" A PIR

11636** 11202** 11642** 11212** 11682** 11602** 11627** 11222** 11647**

*Available only in UK **Not available in UK

BATHROOM, SHOWER,TOILET

M 100/4" A MHC

11232**

M 100/4" AT LL

11203 +
22157

M 100/4" 12 V T HCS

M 100/4" LL

11684**

M 100/4" A PIR LL

11203 +
22153

M 100/4" 12 V MHC

M 100/4" P LL

11601

M 100/4" T HCS

11223 +
22150

M 100/4" 12 V A

M 100/4" T LL

11611

M 100/4" AT HCS

11223 +
22152*

M 100/4" 12 V AP

M 100/4" PIR LL

11612**

M 100/4" AT HCS LL

11223 +
22151

M 100/4" 12 V AT

M 100/4" T HCS LL

11637

M 100/4" A MHC LL

11223 +
22157

M 100/4" 12 V AT HCS

M 100/4" MHC LL

11203 +
22150

M 100/4" 12 V

11223 +
22153

M 100/4" 12 V A MHC

11203

M 100/4" A LL

+

M 100/4" 12 V P

­

22152*

11203

M 100/4" AP LL

+

M 100/4" 12 V T

­

22151

11301 11741 11311 11781 11321 11746

M 120/5" M 120/5" P M 120/5" T M 120/5" PIR M 120/5" A M 120/5" AP

11331 11783** 11302** 11742** 11312** 11782**

UTILITY ROOM

M 120/5" AT

11322**

M 120/5" A PIR

11747**

M 120/5" LL

11332**

M 120/5" P LL

11784**

M 120/5" T LL

11701

M 120/5" PIR LL

11721

M 120/5" A LL M 120/5" AP LL M 120/5" AT LL M 120/5" A PIR LL M 120/5" T HCS M 120/5" AT HCS

11737 11702** 11722** 11726** 11736** 11727**

**Not available in UK
M 120/5" A MHC LL M 120/5" T HCS LL M 120/5" AT HCS LL M 120/5" MHC M 120/5" A MHC M 120/5" MHC LL

11401 11851 11411 11881 11421 11856

M 150/6" M 150/6" P M 150/6" T M 150/6" PIR M 150/6" A M 150/6" AP

11431 11883** 11402** 11853** 11412** 11422**

M 150/6" AT

KITCHEN 11857**

M 150/6" A PIR

11432**

M 150/6" LL

11882**

M 150/6" P LL

11884**

M 150/6" T LL

11801

M 150/6" A LL

11808

M 150/6" AP LL M 150/6" AT LL M 150/6" PIR LL M 150/6" A PIR LL M 150/6" T HCS M 150/6" AT HCS

11837 11802** 11809** 11826** 11836** 11827**

**Not available in UK
M 150/6" A MHC LL M 150/6" T HCS LL M 150/6" AT HCS LL M 150/6" MHC M 150/6" A MHC M 150/6" MHC LL

23

16_26 PUNTO DEF1 12-11-2008 11:22 Pagina 24
VORTICE® PUNTO ACCESSORIES

KIT TO WINDOW-MOUNT ANY VORTICE® PUNTO MODEL

 Will allow any Vortice® Punto unit to be fitted to any single or double glazed window.
 The data and performances for the product + kit are IMQ Performance certified.
 The kit consists of closed-cell, expanded-polyethylene gasket and external grille, intermediate flange fitting, spacer, and a antiUV-threaded ABS ring.

 Glass thickness: 2/3 mm (min) 17/20 mm (max).
 Conforms to the following standards: CEI EN 60335-2-80 (Part 2: Particular requirements for fans), CEI EN 60529 (Code IP) and CEI 107-53/1986.
Design: F. Trabucco & Associates

Dimensions (mm)

A

B

C

A

B

C

 hole glass thickness max

F 100/4"

158

69

22

123÷128

20

F 120/5"

179

80

33

143÷148

20

F 150/6"

213

87

40

178÷183

20

The following are the performance values for the product + kit

Product

Delivery

Kit

Code W

A

Rpm

Lp dB(A) 3 m

Approvals

kg Insulation

IP

°C max

m3/h l/s

M 100/4" M 120/5" M 150/6"
24

F 100/4" 22131 18 0.1 F 120/5" 22132 20 0.12 F 150/6" 22133 30 0.15

2300 85 23.6

38

2000 140 38.9 40.5

1950 280 77.8 44.5

0.85

cl.II X4

50

1.15

cl.II X4

50

1.56

cl.II X4

50

16_26 PUNTO DEF1 12-11-2008 11:22 Pagina 25
VORTICE® PUNTO ACCESSORIES

 Single-glazed window installation with window kit.
 Double-glazed window installation with window kit.


Ceiling Kit


 Made of soft rubber to prevent water infiltration and to maintain IPX4 protection on all surfaces.

Rubber ceiling kit S 100/4" S 120/5" S 150/6"

Code 22154 22155 22156

Accessories on request (description and data on page 99)

Model

Code Products

Fixed Grille Grille kit

22010
22020
22140 22141 22142 22143

11201 - 11202 - 11203 - 11211 - 11212 - 11221 11222 - 11223 - 11231 - 11232 - 11612 - 11637 11682 - 11684
11301 - 11302 - 11311 - 11312 - 11321 - 11322 11331 - 11332 - 11401 - 11402 - 11411 - 11412 11421 - 11422 - 11431 - 11432 - 11722 - 11737 11782 - 11784 - 11809 - 11837 - 11882 - 11884
11100 - 11101 - 11110 - 11111 11102 - 11103 - 11116 11104 - 11105 - 11117 11110 - 11111

SCNRB recessed electronic speed controller

12971 11201 - 11202 - 11301 - 11302 - 11401 - 11402

C 1.5 electronic speed controller

12966 11201 - 11202 - 11301 - 11302 - 11401 - 11402

SCB Kit

22481 12966

25

16_26 PUNTO DEF1 12-11-2008 11:22 Pagina 26
SPLASHPROOF AXIAL FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG.
VORTICE® PUNTO RANGE 12 V







 For intermittent or continuous ventilation of bathrooms, toilets, kitchens or utility rooms in domestic or commercial business.
 2 models available with or without automatic shutters.
 In the automatic version the shutters positioned behind the front grille automatically open and close slowly when the unit is operated. The shutters are made from shockproof, anti-UV-treated plastic.
 12V motor with shielded poles, bronze bearings and thermal cut-out.
 Data and performaces IMQ Performance certified.
 High airflow rate, low operating noise level and low power consumption due to the wing-

profile blades and motor support.  IPX4 splashproof protection.  Motor support and grille made of
anti-UV ABS.  Conforms to the following
standards: CEI EN 60335-2-80 (Part 2: Special standards for ventilators), CEI EN 60529 (Code IP) and CEI 107-53/1986.
Design: F. Trabucco & Associates
Accessories (description and data on page 25 and 99)
 Window kit.  Ceiling kit.  Fixed grille.  Gravity grille.
Wiring diagrams shown on page XXVII.

 Installation showing extract directly to the outside.  Ceiling installation on up to 4m duct.  Through the wall insulation with wall sleeve and grille.

Product M 100/4" 12 V M 100/4" A 12 V *Available only in UK
Dimensions (mm)

With 12 V Power Supply - Transformer Standard Pull Cord Timer T HCS MHC
22150 22152* 22151 22157 22153
Pressure/performance curve
Pa mmH2O 4

A

C

30 3

20 2

10 1

GA 12V

A

B

C

161

117

65

00 m3/h 0
l /s 0

25

50

75

100

10

20

qv

Product

Code

V ~ 50 Hz

W

Delivery A T/mn

P max

Lp dB(A) 3 m

Approvals

kg Insulation IP

°C max

B m3/h l/s mm H2O Pa
p

11203 12 18 0.1 2300 90 25 3 29

38

M 100/4" 12 V

11223 12 18 0.1 2300 90 25 3 29

38

M 100/4" A

12 V

26

0.6 Selv cl.III

X4

50

0.6 Selv cl.III

X4

50

27_36 DOMESTICO DEF1 12-11-2008 11:29 Pagina 27
WALL, WINDOW AND CEILING MOUNTED AXIAL FAN WITH PULL CORD AND HUMIDISTAT, TWO SPEEDS AND AUTOMATIC SHUTTERS
VORTICE PUNTO M150/6"APHCSDLL LONG LIFE 30.000 h







 For intermittent or continuous ventilation of kitchens, and small/medium rooms in domestic or commercial properties.
 Motor support and grille made of anti-UV ABS.
 Two speed shielded pole motor with ball bearings and thermal cut-out.
 Data and performaces IMQ Performance certified.
 Shutters which slowly open and close when the unit is turned on and off.
 The unit can be window mounted using a Vortice window kit (F150/6" - code 22133).
 The pullcord should be removed, and a remote over ride switch (not supplied) fitted.
 A ceiling kit (S150/6" - code

22156) is required to maintain IPX4 integrity.  Can be used on up to 4 metres of circular ducting with 2 x 90 degree bends.  Conforms to the following standards: CEI EN 60335-2-80 (Part 2: Special standards for ventilators), CEI EN 60529 (Code IP).
Design: F. Trabucco & Associates
Accessories (description and data on page 24, 25 and 99)
 Window kit.  Ceiling kit.  Fixed grille.  Gravity grille.
Wiring diagrams shown on page XXVII.

 Installation showing extract directly to the outside.  Ceiling installation on up to 4m duct.  Through the wall insulation with wall sleeve and grille.

Pull cord feature. An integral pull cord allowing the user to manually switch the unit on at maximum speed. An indicator light is illuminated when in manual over-ride. The over-ride facility can also be connected to a remote switch not supplied).
HCS Feature. Complete with an HCS (Humidity Control System) humidity sensor, the unit switches on at low speed when humidity exceeds the set point, and off again once humidty drops below the set point. The Relative Humidity (R.H.) set point is adjustable between 60% and 80% (±3%). It is also possible to over ride the HCS facility by using the pull cord which switches the fan on at full speed.

Dimensions (mm)
A

Pressure/performance curve
Pa mmH2O 8
C
60 6

pt

E

B

40 4

A

M 150/6"

214

Product Code

B 215
W

D

C

D

E

117

47

156

20 2

00 m3/h 0
l/s 0

100 30

200
60 qv

300

400

90

A

Rpm

Delivery

P max

mm

m3/h

l/s

H2O

Pa

Lp dB(A) 3 m

Approvals

kg

Insulation

IP

°C max

V ~ 50 Hz

min max

min max

max

min

min max

min max

max

min

max

min

min max

M 150/6"

11854

230240

6 30 0.07 0.15 760 2100 110 335 30.5 93.5 0.7 6

6.8 59

24

46

1.1

cl.II X4 50

27


Acrobat Distiller 7.0.5 for Macintosh