Image of a Grundfos MQ series self-priming centrifugal pump.
Diagram showing a pump nameplate with various labeled fields (1-15) indicating pump specifications.
Pos. | Description | Example |
---|---|---|
1 | Type designation | MQ 3-35 A-O-A-BVBP |
2 | Rated flow rate [m³/h] | 3.0 |
3 | Model Characters: 1- 8 Production number 9 - 10 Factory code 11 - 14 Production year and week | 96440338 P7 0127 |
4 | Operating pressure [m] | 22 |
5 | Rated voltage [V~] | 1 x 220-240 V |
6 | Max. head [m] | 35 |
7 | Max. current [A] | 4.0 |
8 | Frequency [Hz] | 50 |
9 | Insulation class | B |
10 | Power input, P1 | 850 |
11 | Max. system pressure/liquid temperature [bar/°CMAX] | 7.5/35 |
12 | Marks of approval | CE |
13 | Enclosure class | 54 |
14 | Country of origin | Made in Italy |
15 | Serial number | Serial number 000001G |
Diagram illustrating the MQ pump type key breakdown, showing how different characters in the model name correspond to pump range, rated flow rate, max head, pump version, pipework connection, materials, and shaft seal.
Example | MQ | 3- | 35 | A- | O- | A- | -BVBP |
---|---|---|---|---|---|---|---|
Pump range | |||||||
Rated flow rate [m³/h] | |||||||
Max. head [m] | |||||||
Code for pump version A: Standard | |||||||
Code for pipework connection O: External thread | |||||||
Code for materials A: Standard | |||||||
Code for shaft seal |
Series of illustrations depicting various service tools: A) Pressure gauge, B) Bit holder, C) Bits kit, D) Ring/open-end spanner, E) Screwdriver (straight slot), F) Screwdriver (cross-head), G) Hexagon socket driver, H) Circlip pliers.
Pos. | Designation | For pos. | Description | Part no. |
---|---|---|---|---|
A | Pressure gauge | SV2061 |
Pos. | Designation | For pos. | Description | Part no. |
---|---|---|---|---|
B | Bit holder | G | 1/4" | SV2011 |
C | Bits kit | 93 | 5 mm hexagon | SV2010 |
D | Ring/open-end spanner | 67 | M8-13 mm | SV0055 |
E | Screwdriver | 91 | Straight slot | |
F | 152, 152b | Cross-head | ||
G | Hexagon socket driver | 42 | 42 mm | |
H | Circlip pliers | 111 | Ø12 mm |
Position numbers of parts (digits) refer to exploded views, sectional drawings and parts lists; position numbers of tools (letters) refer to section 2. Service tools.
Gaskets and O-rings should always be replaced when the pump is overhauled.
Cross-sectional diagram of the pump showing components for shaft seal removal.
Exploded view diagram of shaft seal components (102, 104, 107, 111, 103).
Exploded view diagram of pump chambers, O-rings, and impellers (parts 2, 4, 37, 49, 66, 67, 150).
Cross-sectional diagram of the pump showing assembly of components.
Before initial start-up, pour approx. 5 litres of water into the pump through the priming port, see the installation and operating instructions. When started, the pump will start to evacuate the air contained in the system. Once it starts to deliver water, the pump will change over to normal operation (start/stop).
If no water is delivered within 5 minutes after start-up, the pump will stop automatically as protection against dry running, and alarm will be indicated.
The pump starts when
The pump stops when
The pump stops in case of
If activated, the auto-reset function will cause the pump to restart automatically every 30 minutes for 24 hours in case of any type of fault. After this period, if the fault has not disappeared, the pump will remain in the alarm condition and can only be reset manually, see below.
The pump can be reset manually by
Diagram of the pump control panel with 'On/Off' button, 'Pump on' (green), 'Auto-reset' (green), and 'Alarm' (red) indicator lights.
Illustration | Description |
---|---|
Indicator light (green) | Indicates that the pump is ready for operation. When the indicator light is on, the pump will start automatically when water is consumed. The pump will stop a few seconds after the water consumption has ceased. |
On/off button | The pump is started/stopped by means of the on/off button. The on/off button can also be used for manual resetting in case of an alarm condition: - press once for resetting and - press once more for starting. |
Indicator light (red) | When the indicator light is on, the pump is on standby. |
Pump on (green) | The indicator light is on when the pump is running. |
Auto-reset (green) | As standard, this function is activated on delivery. When the indicator light is:
|
Note: When water is consumed, the pump will start and stop automatically, whether the Auto-reset light is on or off. | |
Alarm (red) | The indicator light is on when the pump is in alarm condition. The alarm condition may have been caused by:
|
Note: The pump settings are stored. After supply failure, the pump will automatically revert to its operating condition when the electricity supply is connected again.
Before starting the fault finding procedure, check the external installation conditions of the pump. For this purpose, see the installation and operating instructions.
Note: It is important to read this section as well as 4.9 Fault finding and 4.10 Fault finding overview thoroughly.
The pictures below show the essential parts that control the MQ pump.
Illustration Description | Component Description |
---|---|
Image of a pressure switch and its electrical symbol (open and closed contacts). | Pressure switch.
|
Image of a flow sensor. | Flow sensor. It is important that the magnet part of the flow wheel is pointing upwards against the sensor part. The sensor is positioned in the part with the wire connections. |
Image of a capacitor with blue, red, and white wires. | Capacitor. Note the wiring of the capacitor. Blue wire from the control panel together with the red wire from the motor. The white wire is solitary. |
Image of the pump motor. | Motor (see 5. Wiring diagram). |
Image of the controller board with various wire connections (Electricity supply, Flow sensor, Pressure switch). | Controller and connections. |
Fault | Cause | Remedy |
---|---|---|
1. The pump does not start. | a) Insufficient water. | Check the water supply/suction pipe. |
b) Overheating due to excessive liquid temperature (above +35°C). | Supply cold liquid to the pump. | |
c) Overheating due to seized-up/choked-up pump. | Contact your pump supplier. | |
d) Too low or too high supply voltage. | Check the supply voltage and correct the fault, if possible. | |
e) No electricity supply. | Connect the electricity supply. | |
f) No water consumption. | Turn on a tap. Check that the height between the top point of the discharge pipe and the pump does not exceed 15 metres. | |
g) The pump is in alarm condition. | Reset the pump by means of the on/off button. See the table in section 4.7. | |
2. The pump does not stop. | a) The existing pipework is leaking or defective. | Repair the pipework. |
3. The pump cuts out during operation. | a) Dry running. | Check the water supply/suction pipe. |
b) Overheating due to excessive liquid temperature (above +35°C). | Supply cold liquid to the pump. | |
c) Overheating caused by:
| Contact your pump supplier. | |
d) Too low supply voltage. | Check the supply voltage and correct the fault, if possible. | |
4. The pump starts and stops too frequently. | a) Leakage in suction pipe or air in the water. | Check the water supply/suction pipe/O-rings on the inlet part. |
b) Too low or too high pressure in pressure tank pos. 42. | Check pressure in pressure tank. The pressure must be 1.5 to 1.7 bar. | |
c) Seized-up or missing non-return valve. | Clean the valve or fit a new non-return valve. | |
5. The pump gives electric shocks. | a) Defective earth connection. | Connect the earth connection to the pump in accordance with local regulations. |
6. The pump starts when no water is consumed. | a) Defective non-return valve or the existing pipework is leaking or defective. | Clean the valve or fit a new non-return valve. |
If the pump does not start when the fault has been corrected, contact your pump supplier or GRUNDFOS for further information.
Start the pump and allow it to run for a minimum of 5 minutes with the tap turned on. Then observe how the system reacts.
Observation | Typical faults |
---|---|
Image of a tap and a pump with a '+' symbol. If the tap is opened too quickly, there will be no alarm indication. | Pressure switch, Controller If the flow is lower than 1.2 l/min., the pump does not start and there will be no alarm indication. See 4.10.1 Observation A. |
Image of a tap and a pump with a '+' symbol and a '15 sec.' timer. Water comes out of the tap, but the pump stops every 15 seconds for a short period and starts again right away. The alarm indicator light is off. | Pressure switch, Flow sensor, Controller Water comes out of the tap, but the pump stops every 15 seconds for a short period and starts again right away. The alarm indicator light is off. See 4.10.2 Observation B. |
Image of a tap and a pump with a '+' symbol. No water comes out of the tap. The alarm indicator light is on. | Controller, Capacitor, Motor, Hydraulics No water comes out of the tap. The alarm indicator light is on. See 4.10.3 Observation C. |
Image of a tap and a pump with a '+' symbol. No water comes out of the tap. The alarm indicator light is off. | Controller No water comes out of the tap. The alarm indicator light is off. See 4.10.4 Observation D. |
Illustration of a tap being turned off.
Turn off the tap.
Illustration of a pressure gauge on the pump.
The system is closed; the pressure must be minimum 2.5 bar. If 2.5 bar is not reached, check the hydraulics. If the pressure is above 2.5 bar, continue the fault finding procedure.
Illustration of a non-return valve and a timer showing approx. 15 seconds.
Wait approx. 15 seconds to see what happens when the pump stops. If the pump does not stop, even when the start/stop button is on, replace the controller. If the pressure falls below 2.5 bar, check the non-return valve in the suction line. If the pressure does not fall, continue the fault finding procedure.
Illustration of disconnecting the electricity supply by pulling out the plug.
Disconnect the electricity supply by pulling out the plug.
Illustration of removing the pressure switch plug from the controller.
Remove the pressure switch plug from the controller.
Illustration of a multimeter measuring the pressure switch with the pump under pressure.
At a pressure above 2.5 bar, the switch is closed, and the multimeter must show approx. 0 Ω. If the multimeter shows "OL" or MΩ, the contact is open, and the pressure switch must be replaced.
Illustration of turning on the tap to remove pressure from the system.
Turn on the tap. The pressure is removed from the system.
Illustration of a multimeter measuring the pressure switch with no pressure.
At a pressure below 2 bar, the switch is open, and the multimeter must show "OL" or MΩ. If the multimeter shows approx. 0 Ω, the contact is closed, and the pressure switch must be replaced. If the pressure switch is OK, replace the controller.
Illustration of a tap being turned off.
Turn off the tap.
Illustration of a timer showing 15 seconds.
If the pump enters an alarm condition after 60 sec., replace the pressure switch. If the pump stops within 15 sec. and does not enter an alarm condition, continue the fault finding procedure.
Illustration of disconnecting the electricity supply by pulling out the plug.
Disconnect the electricity supply by pulling out the plug.
Illustration of turning on the tap to remove pressure from the system.
Turn on the tap. Remove the pressure from the system.
Illustration of removing the controller.
Remove the controller.
Illustration of checking the flow sensor housing for impurities.
Check for impurities in the flow wheel housing. Replace the flow sensor if defect.
Illustration of fitting the magnet on the flow wheel against the sensor.
Make sure that the magnet on the flow wheel is fitted against the sensor in the flow sensor cover.
Illustration of fitting the controller and cover and connecting electricity supply.
Fit the controller and the cover. Connect the electricity supply.
Illustration of the On/Off button being pressed.
Press the on/off button. Do not forget to turn on the tap.
Illustration of water flowing from a tap.
If the pump delivers water without stopping/starting at intervals of 15 seconds, the pump is OK. Otherwise, the controller must be replaced.
Illustration of a non-return valve in an inlet pipe.
Check that the inlet conditions are satisfactory.
Illustration of pouring water into the pump (priming).
Prime the pump.
Illustration of disconnecting the electricity supply by pulling out the plug.
Disconnect the electricity supply by pulling out the plug.
Illustration of checking if the pump is seized-up with a screwdriver.
Check if the pump is seized-up by means of a screwdriver. If it is impossible to turn the motor and pump, the hydraulics must be checked. See the exploded drawing.
Illustration of bypassing the controller by connecting motor lead to mains cable.
Bypass the controller by connecting the motor lead to the mains cable.
Illustration of fixing the cover on the pump and connecting electricity supply.
Fix the cover on the pump and connect the electricity supply.
Illustration of a timer showing max. 5 minutes.
Wait approx. 5 min. or until water comes out of the tap.
Illustration of two scenarios: pump delivers water or not.
If the pump delivers water, the controller must be replaced. If the pump delivers no water, continue the fault finding procedure.
Illustration of disconnecting the electricity supply by pulling out the plug.
Disconnect the electricity supply by pulling out the plug.
Illustration of a capacitor with wires (White, Red, Blue).
Replace the capacitor. If available, a measuring instrument capable of measuring 25 microfarad can be used to measure the capacitor for failures before it is replaced. The blue wire from the capacitor must be connected with the red wire to the motor. The white wire is not connected to other wires.
Illustration of fixing the cover on the pump and connecting electricity supply.
Fix the cover on the pump and connect the electricity supply.
Illustration of a timer showing max. 5 minutes.
Wait approx. 5 min. or until water comes out of the tap.
Illustration of two scenarios: pump delivers water or not.
If the pump delivers water, it is OK. Connect the controller correctly. If the pump does not deliver water, continue the fault finding procedure. The controller continues to be bypassed.
Illustration of disconnecting the electricity supply by pulling out the plug.
Disconnect the electricity supply by pulling out the plug.
Illustration of dismantled hydraulic parts.
Dismantle the hydraulic part and check for defects, dirt and wear.
Illustration of connecting electricity supply by plugging the pump into the mains.
Connect the electricity supply by plugging the pump into the mains.
Illustration of checking if the motor can rotate.
Check that the motor can rotate. If the motor cannot rotate, replace it. If the motor can rotate, the hydraulics are faulty. See the exploded drawing.
Illustration of connecting the controller correctly.
Do not forget to connect the controller correctly after completing the fault finding procedure.
Illustration of the controller.
Replace the controller.
Detailed electrical wiring diagram for the Grundfos MQ pump, showing connections between the electrical motor, capacitor, ground, phase, neutral, flow sensor, and pressure switch. The diagram includes labels for White (aux), Red (main), Yellow-green, Black, Blue, Orange wires, and indicates connections to Mains, Flow sensor, and Pressure switch.
Motor [V/Hz] | Reading point | Winding | Resistance [Ω±10%] | Ambient temperature | |
---|---|---|---|---|---|
[°C] | [°F] | ||||
230/50 | A-B | Main | 6.4 | 21 | 70 |
230/60 | A-C | Aux | 16.7 | ||
120/60 | A-B | Main | 1.5 | ||
A-C | Aux | 6.1 |
The measurement can be done with or without cables connected to the PCB and the capacitor.
![]() | Grundfos MQ Series Pressure Booster Pump Installation and Operating Instructions Comprehensive installation and operating instructions for the Grundfos MQ series pressure booster pumps, including models MQ 3-25, MQ 3-35, and MQ 3-45. This manual covers setup, operation, technical data, and troubleshooting for residential and garden water supply applications. |
![]() | Grundfos MQ Installation and Operating Instructions Comprehensive guide for the installation, operation, and maintenance of the Grundfos MQ pump. Covers safety, technical specifications, functions, troubleshooting, and disposal. |
![]() | Grundfos SB, SBA, SB HF Submersible Pumps: Installation and Operating Manual Comprehensive installation and operating manual for Grundfos SB, SBA, and SB HF submersible pumps, covering safety, setup, electrical connection, commissioning, maintenance, troubleshooting, and technical specifications for efficient water pressure boosting and rainwater harvesting. |
![]() | Grundfos Submersible Borehole Pumps for Efficient Groundwater Extraction Discover Grundfos SQ and SQE submersible borehole pumps designed for efficient groundwater extraction in domestic and holiday homes. Learn about their features, benefits, and technical specifications, including constant pressure solutions with SQE models. |
![]() | Grundfos SCALA1 Pressure Booster Pump: Installation and Operation Guide This guide provides detailed instructions for installing and operating the Grundfos SCALA1 pressure booster pump, covering technical specifications, connection methods, control panel functions, and app integration. |
![]() | Grundfos SCALA Installation and Operating Instructions This document provides comprehensive installation and operating instructions for the Grundfos SCALA domestic water supply pumps. It covers general information, receiving and inspecting the product, installation procedures, startup, operation, control functions, servicing, fault finding, and disposal. Designed for professional installers, it ensures safe and efficient use of the SCALA pump. |
![]() | Grundfos SCALA2 3-45 A Pressure Boosting Pump Specifications and Features Detailed specifications and features of the Grundfos SCALA2 3-45 A, a fully integrated, self-priming, compact waterworks for pressure boosting in domestic applications. Includes installation steps, technical data, and material information. |
![]() | Grundfos SCALA2 Installation and Operating Instructions Comprehensive guide for the installation and operation of the Grundfos SCALA2 pump, covering product introduction, installation requirements, mechanical and electrical connections, startup procedures, control functions, troubleshooting, and technical data. |