STEAM GENERATOR

30 nov 2023 — IMPORTANT: INSTALL WITH ARROWS POINTING UP. WARNING: Unit must be installed. INDOORS, in a DRY, NON-FREEZING location and with arrows pointing up.

Brizo-Mystix 10kW Steam Shower Generator-Specs

Brizo Mystix™ 10kW Generator | Steam Sauna Bath

PDF preview unavailable. Download the PDF instead.

Brizo-Mystix 10kW Steam Shower Generator-Specs
8GE-TSG07-240-1 8GE-TSG07-208-1 8GE-TSG07-208-3 8GE-TSG10-240-1 8GE-TSG10-208-1 8GE-TSG10-208-3

3" max

Mounting Holes 14"
Water Inlet " Compression Fitting
¾" Steam Outlet ¾" Safety Relief Valve

Knockouts for Control Cables

1/2" Capped Drain Line for Optional Auto Drain

Rear Side View

Back View

*Add ¼" to the dimension for the louvers *15"

Access Panel

IMPORTANT:
INSTALL WITH ARROWS POINTING UP
WARNING: Unit must be installed INDOORS, in a DRY, NON-FREEZING location and with arrows pointing up. Service by authrorized personnel only.
NOTE: Read all instructions before installation CAUTION: To prevent internal damage hold all fittings securely while making plumbing connections. NOTE: See Wiring Diagram on reverse side of cover. CAUTION: Turn off electric before removing cover.

NOTE: This is NOT intended to be used for space

heating purposes.

009-1081

Top of Access Panel
Top View
*6" 2"

2¾"

SER NO.
NO.

SIZE

IN.

MODEL

SET

PSIG

CAP LBS/HR

MODEL NO. SERIAL NO.
VOLTS

C ® US
LISTED 995C HEATER LOAD
PH MAX AMPS kW

CONTROL CIRCUIT

VOLTS

AMPS

50/60 HZ

2"

15½" 12" 9" 7" 1"

Front Access

Front Side View

Steam Generator Speci cation Chart

Product Number

KW Rating

*Max. Cu. Ft. Range

8GE-TSG07-240-1

7.5

250

8GE-TSG07-208-1

8GE-TSG07-208-3

8GE-TSG10-240-1

10

450

8GE-TSG10-208-1

8GE-TSG10-208-3

Volts/Phase/ Max. Amps
240/1/31 208/1/36 208/3/21
240/1/42 208/1/48 208/3/28

Line Fuse
40 50 30
50 60 40

Dimensions L x W x H
15" x 6" x 15.5"
15" x 6" x 15.5"

*Refer to sizing guidelines to accurately determine the proper size generator for the installation.
90°C copper wire is required for generator connection. Installation shall be in accordance with NEC and
local electrical codes.

Brizo Kitchen & Bath Company reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only. See current full-line price book or www.brizo.com for finish options and product availability. BSP-S-8GE-TSG07-240-1 Rev. A

STEAM GENERATOR
 7.5KW (8GE-TSG07)  10KW (8GE-TSG10)
FEATURES:
· Selectable "RapidMist" · Proportional and Steady Steam · "Gangable" up to (4) generators · Microprocessor based diagnostics and LED
indication · Stainless Steel tank construction · Intelligent control communication · Compact design permits generator installation in a
vanity, a closet or an insulated attic or basement · Includes 35 ft cable (other extension cords sold
separately)
STANDARD SPECIFICATIONS:
· Water Supply - 3/8" Compression Fitting, 120 PSI max · Steam Outlet - 3/4" Brass NPT male thread · Pressure Relief Valve - 3/4" NPT female thread · Drain Outlet - Capped 1/2" Brass NPT male thread · Generator shipping weight - 30 lbs · For optimum performance, the steam generator
should be mounted as close as possible to the stream room. If needed, the steam pipe may be up to 50' long. · Steam Generators should be accessible for service. · Steam generators must NOT be installed outdoors, in moist, humid areas, in areas prone to freezing, or in areas where temperatures can exceed 104°F. · Steam head to be mounted 12" to 18" above floor or 6" above rim of tub and as far from the seating area as possible. Do not locate below the user control. · Service Access - Minimum 21" L x 20" W x 22" H (28" L with Auto Drain). · Required Equipment - 8CH-250L, 8CB-250L, 8CH-250R, 8CB-250R, 8CH-600S OR 8CB-600S control interface and steam head · Required Electrical Service - Dedicated circuit required: See Specification Chart for proper electrical requirements.
STEAM ROOM GUIDELINES
· Steam room must be completely enclosed, with full walls, doors, floor and ceiling.
· It is recommended that a gasketed door is used for steam containment.
· To prevent slip and fall hazards, non-slip flooring or non-slip floor strips must be installed in the steam room.
· Check the suitability of any materials with the manufacturer. Walls and ceilings must be constructed of water-resistant, non-corrosive surface, such as tile, marble, or other non-porous material.
· The ceiling may be sloped to prevent dripping of condensate.
· Provide a floor drain. · No heating, venting or air conditioning devices
should be installed inside the steam room. · Exterior windows inside the steam room should
be double paned and tempered safety glass. · Limit steam room ceiling height to 8 feet.
Exceeding 8 feet will require a higher-rated steam generator and may cause poor performance. Max ceiling height is 10 feet.
WARRANTY
· See separate warranty document
COMPLIES WITH:
· UL/cUL Listed
Brizo Kitchen & Bath Company 55 E. 111th Street, Indianapolis, Indiana 46280 350 South Edgeware Road, St. Thomas, ON N5P 4L1 © 2023 Brizo Kitchen & Bath Company


Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)