Emerson Power Supply 7000 User Guide
ef1afd53-07ec-4167-9060-5fe9f3b3e6df Operator's
7000 Series ACTS
Manual
Automatic ClosedTransition Transfer Switches Hdesign 600 through 1200 amps
TABLE OF CONTENTS section-page
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Mounting and Line Connections . . . . . . . . . 1-1 Auxiliary Circuits and Harness . . . . . . . . . . . 1-2 Engine Starting Contacts . . . . . . . . . . . . . . . 1-2 Functional Test . . . . . . . . . . . . . 1-2, 1-3, 1-4, 1-5
TESTING & SERVICE . . . . . . . . . . . . . . . . . . 2-1 Transfer Test . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Preventive Maintenance . . . . . . . . . . . . . . . . 2-1 Disconnecting the Controller . . . . . . . . . . . . 2-1 Manual Load Transfer . . . . . . . . . . . . . . . . . . 2-2 Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . 2-2
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . back cover
Note: Refer to the outline and wiring drawings provided with your 7000 Series ACTS for all installation and connection details and accessories.
An experienced licensed electrician must install the ACTS.
DANGER is used in this manual to warn of high voltages capable of causing shock, burns, or death.
!
WARNING is used in this manual to warn of possible personal injury.
!
CAUTION is used in this manual to warn of possible equipment damage.
Refer to Group 5 Controller User's Guide 381333126 for ATS status display messages, time delays, pickup & dropout settings, and adjustments.
1200 amp. size
600---1000 amp. size
50 Hanover Road, Florham Park, New Jersey 079321591 USA For sales or service call 1 800 8002726 (ASCO) www.ascopower.com
381333203 C
ASCO POWER TECHNOLOGIES CANADA PO Box 1238, 17 Airport Road, Brantford, Ontario, Canada N3T 5T3 telephone 519 7588450, fax 519 7580876, for service call 1 888 2342726 (ASCO) www.asco.ca
Rating Label
Each Automatic ClosedTransition Transfer Switch contains a rating label to define the loads and fault circuit withstand/ closing ratings. Refer to the label on the Transfer Switch for specific values.
!
Do not exceed the values on the rating label. Exceeding the rating can cause personal injury
or serious equipment damage.
Nameplate
The Transfer Switch nameplate includes data for each specific 7000 Series ACTS. Use the switch only within the limits shown on this nameplate. A typical Catalog Number is shown on the next page with its elements explained.
Catalog Number Identification
Typical 7000 Series ACTS catalog no. for switched neutral, 3 pole, 800 amp, 480 V, ATS in Type 1 enclosure:
H7ACTS
B3
800
N5 C
Neutral A solid B switched
blank none
power connections
ground lug
Phase Poles 2 single Ø 3 three Ø
Amperes
600 800 1000 1200
field connections terminal block TB
Voltage
C 208 D 220 E 230 F 240 G 277 H 380 J 400
K 415 L 440 M 460 N 480 P 550 Q 575 R 600
Controller
5 standard 5X if
accessories ordered
Enclosure
C type 1 F type 3R G type 4 * L type 12 *
blank open type
* available 6001000 amp. sizes only
Transfer Control & lights
Transfer Switch
Group 5 Controller
ground lug
power connections
8001000 amp. sizes in typical enclosure with location of customer connections
field connections terminal block TB
power connections
Transfer Switch
power connections
ground lug
Transfer Control & lights
Group 5 Controller
1200 amp size in typical enclosure with location of customer connections
SECTION 1
ASCO 7000 Series Automatic ClosedTransition Transfer Switches (ACTSs) are factory wired and tested. Field installation requires mounting and connection of service cables, and auxiliary control circuits (if required).
Remove the Shipping Skid (large ACTSs)
For large ACTSs, open the front door and remove the four lag screws (2 in front, 2 in rear) securing enclosure to the wood skid.
INSTALLATION
Testing Power Conductors
Do not connect the power conductors to the transfer switch until they are tested. Installing power cables in conduit, cable troughs and ceiling-suspended hangers often requires considerable force. The pulling of cables can damage insulation and stretch or break the conductor's strands. For this reason, after the cables are pulled into position, and before they are connected, they should be tested to verify that they are not defective or have been damaged during installation.
Supporting Foundation
The supporting foundation for the enclosure must be level and straight. Refer to the applicable enclosure outline drawing included with the switch for all mounting details including door opening space.
If bottom cable entry is used, the foundation must be prepared so that the conduit stubs are located correctly. Refer to the enclosure outline drawing for specified area and location. Provide cable bending space and clearance to live metal parts. When a concrete floor is poured, use interlocking conduit spacer caps or a wood or metal template to maintain proper conduit alignment.
Mounting
Refer to the applicable enclosure outline drawing furnished with this switch and mount the automatic transfer switch according to details and instructions shown on diagram.
Line Connections
Refer to the Wiring Diagram provided with the switch. All wiring must be made in accordance with the National Electrical Code and local codes.
It is unnecessary to remove pole covers from the transfer switch. If you do remove them, reinstall them carefully.
Deenergize the conductors before making any line or auxiliary circuitry connections. Be sure that Normal and Emergency line connections are in proper phase rotation. Place engine generator starting control in the OFF position. Make sure engine generator is not in operation.
!
Protect the automatic transfer switch from construction grit and metal chips to prevent
malfunction or shortened life of the ATS.
Connecting Power Conductors
After the power cables have been tested, connect them to the appropriate terminal lugs on the transfer switch as shown on the wiring diagram provided with the switch. Make sure the lugs provided are suitable for use with the cables being installed. Standard terminal lugs are solderless screw type and will accept the wire sizes listed on the drawings provided with the switch. Be careful when stripping insulation from the cables; avoid nicking or ringing the conductor. Remove surface oxides from cables by cleaning with a wire brush. When aluminum cable is used, apply joint compound to conductors. Tighten cable lugs to the torque specified on rating label.
Controller Ground
A grounding wire must be connected to the controller's lower left mounting stud. Because the controller is mounted on the enclosure door, a conductive strap must be used between the enclosure and the door. This connection provides proper grounding which does not rely upon the door hinges.
Harnesses
The transfer switch is connected to the left side of the controller by a plugin harness (two plugs).
1 --- 1
INSTALLATION
Engine Starting Contacts
All customer connections, including the engine control contact connections, are located on terminal block TB which is mounted on the top right side of the enclosure. Refer to the wiring diagram provided with the automatic transfer switch and connect the engine start wires to the appropriate terminals. See Figure 11 and Table A.
Table A. Engine start connections.
(continued)
When normal source fails
contact closes
contact opens
Terminals on Terminal Block TB
TB1 and TB2
TB1 and TB3
Note: To temporarily disable engine control from the automatic transfer switch you can unplug J3 from the small P3 receptacle at the bottom of the assembly. Be sure to reconnect plug J3 to the P3 receptacle for automatic transfer switch operation.
engine start connections
on customer terminal block TB
Auxiliary Circuits
Connect auxiliary circuit wires to appropriate terminals on transfer switch terminal block TB as shown on the wiring diagram provided with this automatic transfer switch.
Figure 1-1. Customer terminal block on the top right side of the enclosure.
Functional Test
The Functional Test consists of three checks:
1 -- Manual Operation Test, page 13 2 -- Voltage Checks, page 14 3 -- Electrical Operation, page 15
!
Do these checks in the order presented to avoid damaging the ACTS.
Read all instructions on the Wiring Diagram and labels affixed to the automatic transfer switch. Note the control features that are provided and review their operation before proceeding.
Note the position of the contact shafts as shown below.
Emergency contacts (upper shaft)
window indicators O is open C is closed
contact position indicators (right side)
Normal contacts (lower shaft)
Figure 1-2. Contact position indicators. Shown with Emergency open and Normal closed.
Continue to 1 Manual Operation Test on next page.
1 --- 2
INSTALLATION (continued)
1 Manual Operation Test
A detachable maintenance handle is provided on the frame of the Transfer Switch for maintenance purposes only. Manual operation of the transfer switch should be checked before it is energized (operated electrically).
!
left side of transfer switch
Do not manually operate the transfer switch until both power sources are disconnected:
open both circuit breakers.
1. After deenergizing both power sources, open the enclosure door. Locate and remove the maintenance handle from the clips on the left side of the transfer switch frame. Insert the handle into the hole in the molded hub on the left side of the operator. See Figures 13 through 15 and Table B.
2. Move the maintenance handle up or down as shown to manually operate the transfer switch. The transfer switch should operate smoothly without binding. If it does not, check for shipping damage or construction debris. Operate both upper and lower contact shafts.
3. Return the transfer switch to the Normal position. Observe that the window indicators (right side) show the upper shaft O (Emergency open) and the lower shaft C (Normal closed). Remove the maintenance handle and store it on the frame in the clips provided.
Emergency source contact shaft hub
maintenance handle
clip
Normal source contact shaft hub
Table B. Maintenance handle positions.
ATS Position
Handle up
Indicators
E Normal
N
E=O
upper contacts open
up N=C
lower contacts closed
E Emergency
N
down
E=C
upper contacts closed
N=O
lower contacts open
down
Note: If Normal and Emergency connections are reversed this operation is also reversed.
Now continue to 2 Voltage Checks on the next page.
Figure 1-3. Maintenance handle storage location. Hubs shown with Normal closed & Emergency open.
handle
UP opens the Emergency source contacts
hub frame
UPPER SHAFT
DOWN closes the Emergency source contacts
Figure 1-4. Emergency (upper shaft) operation.
handle
UP closes the Normal source contacts
hub frame
LOWER SHAFT
DOWN opens the Normal source contacts
Figure 1-5. Normal (lower shaft) operation.
1 --- 3
observe these lights
INSTALLATION (continued)
Automatic Closed Transition Transfer Switch
Transfer Switch Connected To Normal
Transfer
Transfer Switch
Control
Connected To
Emergency
( ) Retransfer Delay Bypass
Transfer Test
HOLD FOR 15 SECONDS
GREEN
RED
Normal Source Accepted
Emergency Source
Accepted
GREEN
RED
Extended Parallel
Time
Failure To
Synchronize
TS Locked
Out
RED
RED
RED
Alarm Reset
Closed Transition
Bypass
Figure 1-6. Standard controls and indicators.
2 --- Voltage Checks
First check nameplate on transfer switch; rated voltage must be the same as normal and emergency line voltages.
!
Before energizing the switch check to be sure that both normal and emergency contacts are not left in the closed position.
!
Verify that the feeders have been connected to the proper lugs.
Use extreme caution when using a meter to measure voltages. Do not touch power termi-
nals; shock, burns, or death could result !
Perform steps 1 through 6 at the right. Observe the status lights. See Figure 1---6.
Black square means light is on. White square means light is off.
* If necessary, adjust voltage regulator on the generator according to the manufacturer's recommendations. The Automatic Transfer Switch will respond only to the rated voltage specified on the Transfer Switch nameplate. Note: Refer to Section 3 of Group 5 Controller User's Guide 381333126 for how to display the Status of the ATS and the Voltage and Frequency of each source.
Now continue to 3 --- Electrical Operation on next page.
Close the normal source circuit breaker. The Transfer Switch 1 Connected To Normal and the Normal Source Accepted lights should come on.
Use an accurate voltmeter to check phase to phase and 2 phase to neutral voltages present at the transfer switch normal source terminals.
Close the emergency source
circuit breaker. (Start generator,
3
if necessary.) The Transfer Switch Connected To Normal &
Emergency Source Accepted
lights should come on.
Use an accurate voltmeter to check phase to phase and 4 phase to neutral voltages present at the transfer switch emergency source terminals.*
Use a phase rotation meter to
5
check phase rotation of emergency source; it must be the
same as the normal source.
A BC
Shut down the enginegenerator, if applicable. The Emergency Source Accepted light should 6 go off. Then put the starting control selector switch (on the generator set) in the automatic position. Close enclosure door.
1 --- 4
observe these lights
INSTALLATION (continued)
Automatic Closed Transition Transfer Switch
Transfer Switch Connected To Normal
Transfer
Transfer Switch
Control
Connected To
Emergency
( ) Retransfer Delay Bypass
Transfer Test
HOLD FOR 15 SECONDS
GREEN
RED
Normal Source Accepted
Emergency Source
Accepted
GREEN
RED
Extended Parallel
Time
Failure To
Synchronize
TS Locked
Out
RED
RED
RED
operate this switch
Alarm Reset
Closed Transition
Bypass
Figure 1-7. Standard controls and indicators.
3 --- Electrical Operation
This procedure will check the electrical operation of the Automatic ClosedTransition Transfer Switch. See Figure 1---7.
!
Close the enclosure door first.
Transfer Test Both normal and emergency sources must be available and the emergency source generator (if used) must be capable of being started in this procedure. Perform steps 1 through 5 at the right. Observe the status lights.
Black square means light is on. White square means light is off.
** If you do not want closedtransition transfer, press the Closed Transition Bypass pushbutton while the controller display shows Waiting for InSync. This action causes opentransition (momentary load interruption) transfer to the opposite source, if conditions permit. Also refer to the Group 5 Controller User's Guide 381333126.
This completes the Functional Test of the ACTS.
The Transfer Switch Connected 1 To Normal and Normal Source
Accepted lights should be on.
Turn and hold Transfer Control
switch clockwise to Transfer Test
2
until the engine starts and runs (within 15 sec.). Emergency
Source Accepted light should
come on.
Transfer switch CE closes and then Transfer Switch CN opens (closedtransition overlap). The Transfer Switch Connected To 3 Emergency light should come on and the Transfer Switch Connected to Normal light goes off (you might see and hear the brief overlap transfer). **
Transfer switch will operate back
to Normal position after Feature
3A time delay. For immediate
retransfer turn Transfer Control
4
counterclockwise to Retransfer Delay Bypass. The Transfer
Switch Connected To Normal light
should come on; Transfer Switch
Connected to Emergency light
should go off.
The enginegenerator will stop after the Feature 2E time delay 5 (unloaded running engine cooldown). The Emergency Source Accepted light should go off.
1 --- 5
SECTION 2 TESTING & SERVICE
TRANSFER TEST Operate the 7000 Series ACTS at least once a month by following the fivestep Electrical Operation Transfer Test procedure on page 15.
PREVENTIVE MAINTENANCE Reasonable care in preventive maintenance will insure high reliability and long life for the 7000 Series ACTS. An annual preventive maintenance program is recommended.
In the United States, ASCO Services, Inc. (ASI) is ASCO Power Technologies's national service organization. ASI can be contacted at 1-800-800-2726 (ASCO) for information on preventive maintenance agreements.
In Canada, for service call 1-888-234-2726 (ASCO).
Checklist for Yearly Inspection
Hazardous voltage capable of causing shock, burns, or death is used in this transfer switch. Deenergize both Normal Emergency power
sources before performing inspections!
Clean the ACTS enclosure. Brush and vacuum
away any excessive dust accumulation. Remove any moisture with a clean cloth.
Check the transfer switch contacts. Remove the
transfer switch barriers and check contact condition. Replace the contacts if they become pitted or worn excessively. Reinstall the barriers carefully.
Maintain transfer switch lubrication. If the
transfer switch is subjected to severe dust or abnormal operating conditions, renew factory lubrication on all movements and linkages. Relubricate the solenoid operator if the TS coil is replaced. Do not use oil; order lubrication kit 75-100.
Check all cable connections & retighten them.
REPLACEMENT PARTS Replacement parts are available in kit form. When ordering parts provide the Serial No., Bill of Material No. (BOM), and Catalog No. from the transfer switch nameplate. Contact your local ASCO Power Technologies Sales Office or ASI: in United States call 1 800 800 ASCO (2726)
or in Canada call 1 888 234 ASCO (2726)
DISCONNECTING THE CONTROLLER
The harness disconnect plugs are furnished for repair purposes only and should not have to be unplugged. If the controller must be isolated, follow these steps:
Disconnecting the Plugs
!
Do not unplug the controller until steps 1a or 1b is completed.
1. Observe the position of the transfer switch. a. If the transfer switch is in the Normal position, first place standby engine starting control in the off position. Second, then open the emergency source circuit breaker. Third, open the normal source circuit breaker. b. If the transfer switch is in the Emergency position, first open the normal source circuit breaker. Second, place the engine starting control in the test or run position. Third, open the emergency source circuit breaker.
2. Separate the two quick disconnect plugs by squeezing the latches. Do not pull on the harness wires.
Reconnecting the Plugs
!
Do not reconnect the controller until steps 1a or 1b is completed.
1. Observe the position of the transfer switch. a. If the transfer switch is in the Normal position, first be sure that both normal and emergency source circuit breakers are open. Second, be sure that the standby engine starting control is still in the off position. b. If the transfer switch is in the Emergency position, first be sure that both normal and emergency source circuit breakers are open.
2. The two harness plugs and sockets are keyed. Carefully align the plugs with the sockets and press straight in until both latches click. Close the door!
3. Restore the two sources in sequence as follows: a. If the transfer switch is in the Normal position, first close the normal source circuit breaker. Second, close the emergency source circuit breaker. Third, place the standby engine starting control in the automatic position. b. If the transfer switch is in the Emergency position, first close the emergency source circuit breaker. Second close the normal source circuit breaker.
2 --- 1
TESTING & SERVICE (continued)
MANUAL LOAD TRANSFER This procedure will manually transfer the load if the controller is disconnected.
!
Do not manually operate the transfer switch until both power sources are disconnected
(all conductors deenergized).
1. Deenergize both the normal and emergency source conductors (remove fuses or open circuit breakers).
2. Use the maintenance handle to manually operate the transfer switch to the opposite source. First open the closed contacts, then close the other contacts. Do not leave both closed. See Manual Operation on page 13.
3. Then remove the maintenance handle. See page 13.
!
Verify that the maintenance handle has been removed before proceeding!
4. If the transfer switch is in the Emergency position manually start the engine generator and then install emergency source fuse or close the circuit breaker.
TROUBLE-SHOOTING
Note any optional accessories that may be furnished on the ACTS and review their operation. Refer to any separate drawings and/or instructions that may be packed with the ACTS.
Hazardous voltage capable of causing shock, burns, or death is used in this switch.
Do not touch the power or load terminals of the transfer switch!
Table 2-1. Trouble-Shooting Checks.
PROBLEM
Enginegenerator set does not start when the Transfer Control switch is turned and held in Transfer Test position or when normal source fails.
Transfer switch does not transfer the load to the emergency source after the enginegenerator set starts.
Transfer switch does not transfer the load to normal source when normal returns or when the Transfer Control switch is released.
Gen. does not stop after load retransfer to normal source.
Failure to Synchronize light comes on.
Extended Parallel Time light comes on. TS Locked Out light comes on.
CHECK IN NUMERICAL SEQUENCE
1 OPERATION
2 GEN-SET
Hold Transfer Test switch 15 Starting control must be in the
seconds or the outage must automatic position. Batteries
be long enough to allow for must be charged and
Feature 1C time delay plus connected. Check wiring to
engine cranking and starting. engine starting contacts.
3 VOLTAGE ---
Wait for Feature 2B time delay to time out.
Generator output circuit breaker must be closed. Generator frequency must be at least 95% of nominal (57 Hz
for a 60 Hz system.) *
Voltmeter should read at least 90% of nominal phase to phase voltage between terminals EA and EC (or EL1 and EL2 for 2 pole switches)*
Wait for Feature 3A time delay to time out.
Voltmeter should read at least
90% of nominal phase to
---
phase voltage between terminals NB and NC, NC and
NA, and NA and NB (or NL1
and NL2 for 2 pole switches).
Wait for Feature 2E time delay Starting control must be in the
to time out.
automatic position.
---
Conditions of Normal or Emergency Sources not suitable for closed transition transfer. Recheck voltage and frequency of both sources. Press Alarm Reset pushbutton.
CN and CE contacts are closed longer than setting in the Control Panel. Open the disconnected source circuit breaker, then call your nearest ASCO Service Center for assistance.
Transfer lockout operation has occured; transfer switch is disabled from automatic operation. Open the disconnected source circuit breaker, then call your nearest ASI for assistance.
* These are factory settings. Refer to Group 5 Controller User's Guide.
If the problem is isolated to circuits on the controller or the transfer switch, call your local ASCO Power Technologies sales office or ASI. In the United States, call 18008002726. In Canada, call 18882342726. Furnish the Serial No. and Catalog No. from the transfer switch nameplate.
2 --- 2
INDEX
A
alarm reset, 15, 22 auxiliary circuits, 12
C
cable lugs, 12 preparation, 12
catalog number, inside cover cleaning, 21 closed transition bypass, 15, 22 connections
line, 11 contact position indicators, 13 controller, 11
disconnecting, 21 see Controller User's Guide
E
electrical operation, 15 emergency source accepted light,
14 extended parallel time, 2---2
F
failure to synchronize, 2---2 frequency, generator, 22 functional test, 12, 13, 14, 15
G
ground, controller, 11
H
harness, 11 disconnect plugs, 21
I
inspection, 21 installation, 11 indicators, contact position, 13
L
labels, engine start contacts, 12 rating, cover
lights, 14, 15 lubrication, 21
M
maintenance handle, 13 maintenance, preventive, 21 manual load transfer, 22
warning, 22 manual operation, 13
illustration of, 13 warning, 13
N
nameplate, cover normal source accepted light, 14
O
operation electrical, 15 manual, 13 illustration of, 13 warning, 13
optional accessories see Controller User's Guide
P
parts, 21 phase rotation check, 14 problem, 22
R
rating label, cover replacement parts, 21
S
settings see Controller User's Guide
T
test, functional, 12, 13, 14, 15 time delays, 21
see Controller User's Guide Transfer Control selector switch
Retransfer Delay Bypass, 15 Transfer Test, 15 Transfer Switch Connected To
Emergency light, 15, 21 Transfer Switch Connected To
Normal light, 14, 21 transfer test, 15 transfer to emergency, 15 transfer to normal, 15, 21 troubleshooting, 22 TS locked out, 2---2
V
voltage checks, 14 voltage, pickup and dropout settings
see Controller User's Guide
Printed in U.S.A.
Copyright --- ASCO Power Technologies 2006