Installation Guide for Qubino models including: 09285, Smart Leak Protector
Smart Leak Protector | Smart Solution for water & leakage control
File Info : application/pdf, 2 Pages, 659.33KB
DocumentDocumentSmart Leak Protector EN: The Smart leak protector monitors and controls your water supply MANUAL INCLUSION EN and senses water leakage. It is ideal automation solution for water supply 1. Enable add/remove mode on your Z-Wave gateway (hub) TECHNICAL SPECIFICATIONS control in apartment, house or for your irrigation system. 2. Connect the device to the power supply PACKAGE CONTENTS 3. Press the water valve button on Smart Leak Detector 3 times within 3 seconds (1 click per second). The device has to get On/Off signal 3 Standard package contains: times,. Smart Leak Protector, water leakage sensor, two mounting plugs with a 4. A new device will appear on your dashboard screw M6X45mm, Installation Manual Note: In case of S2 Security inclusion a dialog will appear prompting Power supply Rated load current of DC output (resistive load)* Output circuit power of DC output (resistive load) 24-30VDC 1 X 10A / 24VDC 240W (24VDC) When ordering accessories, the package may also contain any of: you to enter the corresponding PIN number (5 underlined digits) that 24VDC power supply adapter, water meter with pulse reader, water valve are written on the module label and the label inserted in the with electric coil packaging (check the example picture). Operation temperature Z-Wave operation range -10 ~ +40°C (14 ~ 104°F) up to 30 m indoors (98 ft) INSTALLATION IMPORTANT: The PIN code must not be lost Dimensions (WxHxD) (package) 398x220x95 mm / 1. To prevent electrical shock and/or equipment damage, do not connect Z-WAVE EXCLUSION/RESET 15,67x8,66x3,74 in power supply adapter to electrical power before completing installation Z-WAVE EXCLUSION Weight standard package 619g / 21,83 oz or during maintenance. 1. Connect the device to the power supply Electricity consumption 0,4W 2. Be aware that even if the power supply adapter is not connected to 2. Make sure the device is within direct range of your Z-Wave gateway main electrical power, some voltage may remain in the wires -- before (hub) or use a hand-held Z-Wave remote to perform exclusion proceeding with the installation, be sure no voltage is present in the 3. Enable exclusion mode on your Z-Wave gateway (hub) Switching Z-Wave Repeater Relay Yes wiring. 4. Press the water valve button on Smart Leak Detector 3 times within Operating frequency band(s) Z-wave (868Mhz EU frequency) 3. Take extra precautions to avoid accidentally turning on the device 3 seconds during installation. 5. The device will be excluded from your network, but any custom 4. Install the device exactly according to this installation manual see configuration parameters will not be erased. Maximum radio-frequency power <2,5mW transmitted in frequency band(s) attached installation diagrams (on the opposite side): 1. Connect the water meter, water valve, water sensor and power supply. Put aside the two blind covers and decoration frame. Carefully lift the upper part of Smart Leak Protector housing to reveal the terminal for wire connections, marked with + - signs. Use the knife to make hole in the cable fitting at the bottom of the Smart Leak protector housing. Connect the water meter, water valve and leak detector to Qubino Smart Leak Protector as indicated in the picture: 2. Finally connect the 24VDC power supply as indicated. Make NOTE1: LEARN MODE state allows the device to receive network information from the controller. NOTE2: After device is excluded you should wait 30seconds before performing re-inclusion. FACTORY RESET 1. Connect the device to the power supply 2. Within the first minute the device is connected to the power supply, press the water valve button on Smart Leak Detector 5 times within 5 seconds EN *In case of loads other than resistive loads, please pay attention to the value of cos . If necessary, connect loads less powerful than what they're rated for this applies to all motor loads. Max current for cos =0,4 is 3A at 24VDC L/R=7ms. ORDERING CODE AND FREQUENCIES EN ZMNHDXY X, Y values define product version per region. Please check online extended manual or catalogue for the right version. sure that you pull the cables through the cable fitting. 3. Close the Smart Leak Protector housing. Make sure that the cabling inside the housing is not clamped by the housing. Place the Qubino module on the right hand side of By resetting the device, all custom parameters previously set on the device will return to their default values, and a node ID will be deleted. Use this reset procedure only when the gateway (hub) is missing or EN Get a real Qubino Z-Wave bible! How-to install, use cases, user manual, illustrations and more. Scan the QR code/follow the product link below: otherwise inoperable. the box as indicated in the picture 2. Make sure the Qubino module antenna is placed next to housing wall as indicated in picture 2 (see arrow 1). Place the two blind covers as indicated in the picture. Place the blind cover with the label on it to the NOTE: See extended manual for custom settings and parameters https://qubino.com/products/smart-leakage-protector/ available for this device. IMPORTANT DISCLAIMER rightest position (see arrow 2). Press the blinds until you hear a Z-Wave wireless communication is not always 100% reliable. This device click. should not be used in situations in which life and/or valuables are solely 4. Mark the position of the mounting holes dependent on its functioning. If the device is not recognized by your Place the Smart Leak Protector housing on suitable place on the gateway (hub) or shows up incorrectly, you may need to change the wall. Use pencil to mark the position of the mounting holes. See device type manually and make sure your gateway (hub) supports Z- picture 3. Wave Plus devices. Contact us for help before returning the product: 5. Drill the mounting holes and install the Smart Leak Protector http://qubino.com/support/#email SIMPLIFIED EU DECLARATION OF CONFORMITY Use the 6mm drill. Drill the holes at markings 45mm deep. Insert fixings into holes, place the Smart Leak Protector over the holes and insert the two screws. Tighten the screws all the way. See picture 4. 6. Plug the power adapter into power outlet. 7. Power on the Smart Leak Protector Press the Power-on button on Smart Leak Protector. The white light indicates the Smart Leak Protector is turned on. See picture 5. 8. Include the device into the Z-Wave network See Z-Wave inclusion section and picture 6. WARNING Hereby, Goap d.o.o. Nova Gorica declares that the radio equipment type Smart Leak Protector Relay is in compliance with Directive 2014/53/EU. The full text of the EU Do not dispose of electrical appliances as unsorted municipal waste, use declaration of conformity is available at the following internet address: separate collection facilities. Contact your local government for http://qubino.com/products/smart-leak-protector. information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances FCC compliance statement (applies only in the US): can leak into the groundwater and get into the food chain, damaging This device complies with part 15 of the FCC Rules. Operation is subject your health and well-being. When replacing old appliances with new to the following two conditions: (1) This device may not cause harmful ones, the retailer is legally obligated to take back your old appliance for interference, and (2) this device must accept any interference received, disposal free of charge. including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a 5. If you have connected water valve*, press the water valve push button EN Class B digital device, pursuant to part 15 of the FCC Rules. These limits of Smart Leak Protector. Check that the water valve is closed (water flow ELECTRICAL DIAGRAM (24 VDC) are designed to provide reasonable protection against harmful meter is steady) and that button light indicator is ON. Press the button interference in a residential installation. This equipment generates, uses again and verify that the water valve is open (water flow meter is turning) and can radiate radio frequency energy and, if not in-stalled and used in and that button light indicator is OFF. accordance with the instructions, may cause harmful interference to *NOTE: your water valve must be of "Normally Open Valve" type. See your water valve manual for details. radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be SAFETY INFORMATION determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following Danger of electrocution! measures: --Reorient or relocate the receiving antenna. --Increase the Installation of this device requires a great degree of skill and may be separation between the equipment and receiver. --Connect the performed only by a licensed and qualified electrician. Please keep in equipment into an outlet on a circuit different from that to which the mind that even when the device is turned off, voltage may still be present receiver is connected. --Consult the dealer or an experienced radio/ TV in the device's terminals. technician for help. Note! Do not connect the device to loads exceeding the recommended values. Connect the device exactly as shown in the provided diagrams. Improper wiring may be dangerous and result in equipment damage. Notes for diagram: + Positive lead (+VDC) - Negative lead (-VDC) Q Output for electrical device (load) no. 1 Z-WAVE INCLUSION I1 Input used for water-leak detector I2 Input used for water meter pulse reader SMARTSTART INCLUSION I3 Input for push-button switch 1. Scan QR code on device label and add S2 DSK TS Input for temperature sensor (not used in to Provisioning List in gateway (hub) Smart Leak Protector) 2. Connect the device to the power supply CE declaration of compliance is available on product page under www.qubino.com. This user manual is subject to change and improvement without prior notice. Goap d.o.o. Nova Gorica Ulica Klementa Juga 007, 5250 Solkan, Slovenia E-mail: info@qubino.com ; Tel: +386 5 335 95 00 Web: www.qubino.com; Date: 24.03.2021; V 1.0 3. Inclusion will be initiated automatically within few seconds of connection to the power supply and the device will automatically enroll in your network (when the device is excluded and connected to the power supply it automatically enters the LEARN MODE state). EN WARNING: The durability of the device depends on the applied load. For resistive loads (light bulbs, etc.) and 10A current consumption of an electrical device, the product's lifespan exceeds 100,000 toggles. 1 2 3 4 5 6