ASCO Series 300 Power Transfer Switches
Technical Data and Ordering Information
Brand: ASCO Power Technologies
Website: ascopower.com
Ordering Information Structure
To order an ASCO SERIES 300 Power Transfer Switch, a catalog number is constructed by selecting options for FRAME, TRANSITION TYPE, AMPS, PHASE, NEUTRAL CODE, VOLTAGE CODE, GROUP CODE, and ENCLOSURE CODE. The available options for each component are detailed below:
Frame Options:
- Open Transition: D30A-230A
- Open/Delayed Transition: J (150A-600A), H (800A - 1200A), G (1600A - 3000A)
Transition Type Options:
- Automatic: 03ATS Open Transition
- Automatic Delayed: 3ADTS Delayed Transition
- Non-Automatic: 03NTS Open Transition
- Non-Automatic Delayed: 3NDTS Delayed Transition
Amperage Options:
0030, 0070, 0104, 0150, 0200, 0230, 0260, 0400, 0600, 0800, 1000, 1200, 1600, 2000, 2600, 3000
Phase Options:
3-Phase
Neutral Code Options:
- A = Solid Neutral
- B = Switched Neutral
Voltage Code Options:
A2=115V, B2=120V, C=208V, D=220V, E=230V, F=240V, H=380V, J=400V, K=415V, L=440V, M=460V, N=480V, P=550V, Q=575V, R=600V
Group Code Options:
- GX = No Optional Accessories
Enclosure Code Options:
- 0 = Open Type
- C = Type 1 Enclosure
- F = Type 3R8.9 Enclosure
- G = Type 48 Enclosure
- H = Type 4X8 Enclosure (304 Stainless Steel)
- L = Type 12 Enclosure
- M = Type 3R8.9 Secure Double-Door Enclosure
- N = Type 48 Secure Double-Door Enclosure
- Q = Type 12 Secure Double-Door Enclosure
- R = Type 3RX7,8,9 Secure Double-Door Enclosure (304 Stainless Steel)
- S = Type 3RX7,8,9 Secure Double-Door Enclosure (316 Stainless Steel)
- U = Type 4X8 Enclosure (316 Stainless Steel)
- V = Type 4X8 Secure Double-Door Enclosure (316 Stainless Steel)
Notes on Ordering:
- Switch sizes 30-600 amperes supplied in non-secure enclosures as standard.
- 115-120 volt options available for 30-400 amperes only. Contact ASCO for other voltages.
- 200 and 230 amperes rated switches are for use with copper cable only.
- Switch sizes 800-3000 amperes, and 150-400 amperes 3ADTS/3NDTS are provided in secure type outdoor enclosures when required.
- Use Type 3R secure for 1200, 2000, 2600, and 3000 ampere switches.
- Type 304 stainless steel is standard. Suitable for indoor or outdoor use where caustic or alkali chemicals may be present. Type 316 stainless steel is recommended for improved resistance to salt and some chemicals, especially in marine environments.
- Available on switches rated 1200, 2000, 2600, and 3000 amperes.
- When temperatures drop below 32°F (0°C), special precautions like strip heaters are needed to prevent condensation and freezing. This is crucial for outdoor applications with Type 3R, 4 enclosures.
- Type 3R enclosures are not suitable for installations exposed to wind-driven rain or snow. Use Type 4 enclosures or provide supplemental shelter.
Dimensions and Shipping Weights
UL Type 1 Enclosure
FRAME | SWITCH RATING (AMPERES) | PHASE POLES | NEUTRAL CODE | WIDTH (IN./MM) | HEIGHT (IN./MM) | DEPTH (IN./MM) | APPROX. SHIPPING WEIGHT (LB./KG) |
---|---|---|---|---|---|---|---|
303,703,1043 1503, 2003 | 30-200 | 2 | A | 18 (457) | 31 (787) | 13 (330) | 69 (32) |
303,703,1043 1503, 2003 | 30-200 | 2 | B | 18 (457) | 31 (787) | 13 (330) | 72 (33) |
303,703,1043 1503, 2003 | 30-200 | 3 | A | 18 (457) | 31 (787) | 13 (330) | 72 (33) |
303,703,1043 1503, 2003 | 30-200 | 3 | B | 18 (457) | 31 (787) | 13 (330) | 75 (34) |
230 | 230 | 2 | A | 18 (457) | 48 (1219) | 13 (330) | 117 (53) |
230 | 230 | 2 | B | 18 (457) | 48 (1219) | 13 (330) | 125 (57) |
230 | 230 | 3 | A | 18 (457) | 48 (1219) | 13 (330) | 125 (57) |
230 | 230 | 3 | B | 18 (457) | 48 (1219) | 13 (330) | 133 (61) |
260, 400 | 260, 400 | 2 | A | 24 (610) | 56 (1422) | 14 (356) | 250 (113) |
260, 400 | 260, 400 | 2 | B | 24 (610) | 56 (1422) | 14 (356) | 260 (118) |
260, 400 | 260, 400 | 3 | A | 24 (610) | 56 (1422) | 14 (356) | 260 (118) |
260, 400 | 260, 400 | 3 | B | 24 (610) | 56 (1422) | 14 (356) | 270 (123) |
150, 200, 230 3ADTS/3NTS only | 150, 200, 230 | 2 | A | 24 (610) | 56 (1422) | 14 (356) | 250 (113) |
150, 200, 230 3ADTS/3NTS only | 150, 200, 230 | 2 | B | 24 (610) | 56 (1422) | 14 (356) | 260 (118) |
150, 200, 230 3ADTS/3NTS only | 150, 200, 230 | 3 | A | 24 (610) | 56 (1422) | 14 (356) | 260 (118) |
150, 200, 230 3ADTS/3NTS only | 150, 200, 230 | 3 | B | 24 (610) | 56 (1422) | 14 (356) | 270 (123) |
600 | 600 | 2 | A | 24 (610) | 63 (1600) | 17 (432) | 300 (137) |
600 | 600 | 2 | B | 24 (610) | 63 (1600) | 17 (432) | 320 (146) |
600 | 600 | 3 | A | 24 (610) | 63 (1600) | 17 (432) | 320 (146) |
600 | 600 | 3 | B | 24 (610) | 63 (1600) | 17 (432) | 320 (151) |
800, 1000 | 800, 1000 | 2 | A | 34 (864) | 72 (1829) | 20 (508) | 431 (196) |
800, 1000 | 800, 1000 | 2 | B | 34 (864) | 72 (1829) | 20 (508) | 460 (209) |
800, 1000 | 800, 1000 | 3 | A | 34 (864) | 72 (1829) | 20 (508) | 460 (209) |
800, 1000 | 800, 1000 | 3 | B | 34 (864) | 72 (1829) | 20 (508) | 489 (222) |
1200 | 1200 | 2 | A | 38 (965) | 87 (2210) | 23 (584) | 581 (264) |
1200 | 1200 | 2 | B | 38 (965) | 87 (2210) | 23 (584) | 611 (277) |
1200 | 1200 | 3 | A | 38 (965) | 87 (2210) | 23 (584) | 611 (277) |
1200 | 1200 | 3 | B | 38 (965) | 87 (2210) | 23 (584) | 639 (290) |
1600, 2000 | 1600, 2000 | 2 | A | 38 (965) | 87 (2210) | 23 (584) | 1160 (525) |
1600, 2000 | 1600, 2000 | 2 | B | 38 (965) | 87 (2210) | 23 (584) | 1160 (525) |
1600, 2000 | 1600, 2000 | 3 | A | 38 (965) | 91 (2311) | 72 (1829) | 1430 (649) |
2600, 30004 | 2600, 3000 | 3 | B | 38 (965) | 91 (2311) | 72 (1829) | 1495 (679) |
Notes on Dimensions & Weights (UL Type 1):
- Neutral Codes: 0=None, A=Solid, B=Switched.
- Dimensional data is approximate and subject to change. Certified dimensions available upon request.
- Dimensions for 30-200 ampere models with accessory 135L power meter are 18"W x 41"H x 13"D.
- Enclosures for 2600, 3000 amperes are free-standing with removable top, sides, and back.
- Unit is designed for top cable entry of emergency and load, and bottom entry of normal. A cable pull box is also available for all top or bottom cable access when required (optional accessory kit #K609027). Not required for Type 3R, 4X, and 12 enclosures where available.
UL Type 3R, 4 or 12 Enclosure
FRAME | SWITCH RATING (AMPERES) | PHASE POLES | NEUTRAL CODE | WIDTH (IN./MM) | HEIGHT (IN./MM) | DEPTH (IN./MM) | APPROX. SHIPPING WEIGHT (LB./KG) |
---|---|---|---|---|---|---|---|
303,703, 1043 1503, 2003 (Non-Secure Enclosure) | 30-200 | 2 | A | 17.5 (445) | 35 (886) | 11.625 (295) | 84 (38) |
303,703, 1043 1503, 2003 (Non-Secure Enclosure) | 30-200 | 2 | B | 17.5 (445) | 35 (886) | 11.625 (295) | 87 (40) |
303,703, 1043 (Non-Secure Enclosure) | 30-200 | 3 | A | 17.5 (445) | 35 (886) | 11.625 (295) | 87 (40) |
303,703, 1043 (Non-Secure Enclosure) | 30-200 | 3 | B | 17.5 (445) | 35 (886) | 11.625 (295) | 90 (41) |
D (Non-Secure Enclosure) | 230 | 2 | A | 18 (458) | 50.5 (1284) | 14.33 (364) | 90 (41) |
D (Non-Secure Enclosure) | 230 | 2 | B4 or C | 18 (458) | 50.5 (1284) | 14.33 (364) | 132 (60) |
D (Non-Secure Enclosure) | 230 | 3 | A | 18 (458) | 50.5 (1284) | 14.33 (364) | 140 (63) |
D (Non-Secure Enclosure) | 230 | 3 | B4 or C | 18 (458) | 50.5 (1284) | 14.33 (364) | 148 (67) |
260, 400 | 260, 400 | 2 | A | 24 (610) | 63 (1600) | 18.2 (462) | 320 (146) |
260, 400 | 260, 400 | 2 | B | 24 (610) | 63 (1600) | 18.2 (462) | 340 (155) |
260, 400 | 260, 400 | 3 | A | 24 (610) | 63 (1600) | 18.2 (462) | 340 (155) |
260, 400 | 260, 400 | 3 | B | 24 (610) | 63 (1600) | 18.2 (462) | 350 (160) |
150, 200, 230 SERIES 3ADTS/3NTS only (Non-Secure Enclosure) | 150, 200, 230 | 2 | A | 24 (610) | 63 (1600) | 18.2 (462) | 320 (146) |
150, 200, 230 SERIES 3ADTS/3NTS only (Non-Secure Enclosure) | 150, 200, 230 | 2 | B | 24 (610) | 63 (1600) | 18.2 (462) | 340 (155) |
150, 200, 230 SERIES 3ADTS/3NTS only (Non-Secure Enclosure) | 150, 200, 230 | 3 | A | 24 (610) | 63 (1600) | 18.2 (462) | 340 (155) |
150, 200, 230 SERIES 3ADTS/3NTS only (Non-Secure Enclosure) | 150, 200, 230 | 3 | B | 24 (610) | 63 (1600) | 18.2 (462) | 350 (160) |
600 (Secure Enclosure) | 600 | 2 | A | 24 (610) | 63 (1600) | 18.2 (462) | 320 (146) |
600 (Secure Enclosure) | 600 | 2 | B | 24 (610) | 63 (1600) | 18.2 (462) | 340 (155) |
600 (Secure Enclosure) | 600 | 3 | A | 24 (610) | 63 (1600) | 18.2 (462) | 340 (155) |
600 (Secure Enclosure) | 600 | 3 | B | 24 (610) | 63 (1600) | 18.2 (462) | 350 (160) |
800, 1000 (Secure Enclosure) | 800, 1000 | 2 | A | 34 (859) | 72 (1821) | 20 (508) | 519 (236) |
800, 1000 (Secure Enclosure) | 800, 1000 | 2 | B | 34 (859) | 72 (1821) | 20 (506) | 543 (246) |
800, 1000 (Secure Enclosure) | 800, 1000 | 3 | A | 34 (859) | 72 (1821) | 20 (506) | 543 (246) |
800, 1000 (Secure Enclosure) | 800, 1000 | 3 | B | 34 (859) | 72 (1821) | 20 (506) | 565 (257) |
1200 (Secure Enclosure) | 1200 | 2 | A | 41 (1037) | 95.5 (2415) | 33.5 (848) | 1131 (513) |
1200 (Secure Enclosure) | 1200 | 2 | B | 41 (1037) | 95.5 (2415) | 33.5 (848) | 1160 (526) |
1200 (Secure Enclosure) | 1200 | 3 | A | 41 (1037) | 95.5 (2415) | 33.5 (848) | 1160 (526) |
1200 (Secure Enclosure) | 1200 | 3 | B | 41 (1037) | 95.5 (2415) | 33.5 (848) | 1189 (539) |
1600, 2000 (Secure Enclosure) | 1600, 2000 | 2 | A | 42.5 (1074) | 95.5 (2529) | 47 (1189) | 1705 (775) |
1600, 2000 (Secure Enclosure) | 1600, 2000 | 2 | B | 42.5 (1074) | 95.5 (2529) | 47 (1189) | 1830 (832) |
2600, 3000 (Secure Enclosure) | 2600, 3000 | 3 | A | 41 (1037) | 95.5 (2529) | 74 (1872) | 2150 (976) |
2600, 3000 (Secure Enclosure) | 2600, 3000 | 3 | B | 41 (1037) | 95.5 (2529) | 74 (1872) | 2230 (1012) |
Notes on Dimensions & Weights (UL Type 1):
- Neutral Codes: 0=None, A=Solid, B=Switched, C=Overlapping.
- Dimensional data is approximate and subject to change. Certified dimensions available upon request.
- Dimensions for 30-200 ampere models when furnished with accessory 135L power meter are 18"W x 48"H x 13"D.
- 30-1000 ampere switches are available in secure type enclosures, contact ASCO for details.
External Power Connections
SWITCH RATING (AMPERES) | RANGES OF AL-CU WIRE SIZES (UNLESS SPECIFIED COPPER ONLY) |
---|---|
30-2301 ATS and NTS only | One #14 to 4/0 AWG |
1502, 260, 400 | Two 1/0 AWG to 250 MCM or One #4 AWG to 600 MCM |
600 | Two 2/0 AWG to 600 MCM |
800, 1000, 1200 | Four 1/0 to 600 MCM |
1600, 2000 | Six 1/0 to 600 MCM |
2600, 3000 | Twelve 1/0 to 750 MCM |
Notes on External Connections:
- All SERIES 300 switches are furnished with a solid neutral plate (unless switched neutral configuration is specified) and terminal lugs.
- Use wire rated 75°C minimum for all power connections.
- 1. 200 and 230 amperes rated switches for use with copper cable only. Refer to paragraph 310.15 of the NEC for additional information.
- 2. 150 for DTS only.
Withstand and Closing Ratings
FRAME | SWITCH RATING (AMPERES) | PHASE POLES | NEUTRAL CODE | CURRENT LIMITING FUSES 240V MAX. AMPS | CURRENT LIMITING FUSES 480V MAX. AMPS | CURRENT LIMITING FUSES 600V MAX. AMPS | CURRENT LIMITING FUSES MAX. SIZE, CLASS | SPECIFIC BREAKER 480V MAX. AMPS | SPECIFIC BREAKER 600V MAX. AMPS | SPECIFIC BREAKER MAX. SIZE, CLASS | |
---|---|---|---|---|---|---|---|---|---|---|---|
303,703, 1043 1503, 2003 (Non-Secure Enclosure) | 30 | 2 | A | 200 | 200 | J | 22kA | 22kA | |||
303,703, 1043 1503, 2003 (Non-Secure Enclosure) | 30-100 | 2 | B | 200 | 200 | J | 22kA | 22kA | |||
303,703, 1043 (Non-Secure Enclosure) | 30-100 | 3 | A | 200 | 200 | J | 22kA | 22kA | |||
303,703, 1043 (Non-Secure Enclosure) | 30-100 | 3 | B | 200 | 200 | J | 22kA | 22kA | |||
D (Non-Secure Enclosure) | 70-100 | 2 | A | 150kA 85kA 25kA | 200kA 35kA | 200 | J | 22kA | 22kA | ||
D (Non-Secure Enclosure) | 150 | 2 | B4 or C | 150kA | 85kA | 25kA | 200kA 35kA | 200 | J | 22kA | |
D (Non-Secure Enclosure) | 150 | 3 | A | 150kA | 85kA | 25kA | 200kA 35kA | 200 | J | 22kA | |
D (Non-Secure Enclosure) | 150 | 3 | B4 or C | 150kA | 85kA | 25kA | 200kA 35kA | 200 | J | 22kA | |
230 | 200 | 2 | A | 100kA | 300 | J | 200kA 85kA | 14kA | 35kA 35kA | 200 | RK1 |
260, 400 | 260, 400 | 2 | A | 200kA | 600 | J | 65kA | 42kA | 22kA | ||
260, 400 | 260, 400 | 2 | B | 200kA | 600 | J | 65kA | 42kA | 22kA | ||
260, 400 | 260, 400 | 3 | A | 200kA | 600 | J | 65kA | 42kA | 22kA | ||
260, 400 | 260, 400 | 3 | B | 200kA | 600 | J | 65kA | 42kA | 22kA | ||
150, 200, 230 SERIES 3ADTS/3NTS only | 150, 200, 230 | 2 | A | 200kA | 200kA | 42kA | 800 | L | 65kA | 50kA | 42kA |
150, 200, 230 SERIES 3ADTS/3NTS only | 150, 200, 230 | 2 | B | 200kA | 200kA | 42kA | 800 | L | 65kA | 50kA | 42kA |
150, 200, 230 SERIES 3ADTS/3NTS only | 150, 200, 230 | 3 | A | 200kA | 200kA | 42kA | 800 | L | 65kA | 50kA | 42kA |
150, 200, 230 SERIES 3ADTS/3NTS only | 150, 200, 230 | 3 | B | 200kA | 200kA | 42kA | 800 | L | 65kA | 50kA | 42kA |
800, 1000 (Secure Enclosure) | 800 | 2 | A | 200kA | 200kA | 65kA | 1200 | L | 65kA | 150kA | 65kA |
800, 1000 (Secure Enclosure) | 800 | 2 | B | 200kA | 200kA | 65kA | 1200 | L | 65kA | 150kA | 65kA |
800, 1000 (Secure Enclosure) | 1000 | 3 | A | 200kA | 200kA | 65kA | 1200 | L | 65kA | 150kA | 65kA |
800, 1000 (Secure Enclosure) | 1000 | 3 | B | 200kA | 200kA | 65kA | 1200 | L | 65kA | 150kA | 65kA |
1200 (Secure Enclosure) | 1200 | 2 | A | 200kA | 200kA | 85kA | 1600-2000 | L | 85kA | 85kA | 85kA |
1200 (Secure Enclosure) | 1200 | 2 | B | 200kA | 200kA | 85kA | 1600-2000 | L | 85kA | 85kA | 85kA |
1200 (Secure Enclosure) | 1200 | 3 | A | 200kA | 200kA | 85kA | 1600-2000 | L | 85kA | 85kA | 85kA |
1200 (Secure Enclosure) | 1200 | 3 | B | 200kA | 200kA | 85kA | 1600-2000 | L | 85kA | 85kA | 85kA |
1600, 2000 (Secure Enclosure) | 1600, 2000 | 2 | A | 200kA | 200kA | 85kA | 2600-3000 | L | 100kA | 100kA | 100kA |
1600, 2000 (Secure Enclosure) | 1600, 2000 | 2 | B | 200kA | 200kA | 85kA | 2600-3000 | L | 100kA | 100kA | 100kA |
2600, 3000 (Secure Enclosure) | 2600, 3000 | 3 | A | 200kA | 200kA | 125kA | 4000 | L | 125kA | 125kA | 100kA |
2600, 3000 (Secure Enclosure) | 2600, 3000 | 3 | B | 200kA | 200kA | 125kA | 4000 | L | 125kA | 125kA | 100kA |
Notes on Withstand & Closing Ratings:
- * Front connection only.
- All units are RMS Symmetrical Amperes.
- All Withstand and Closing Rating values are tested in accordance with UL 1008. See ASCO Publication 1128 for more information.
- Application requirements may permit higher WCR for certain switch sizes.
Extended Warranties
Extended Warranties for Series 300 Transfer Switches (3ATS/3NTS/3ADTS/3NDTS):
- 1 Year Extension (Total of 3 Years)
- 2 Year Extension (Total of 4 Years)
- 3 Year Extension (Total of 5 Years)
Notes on Warranties: Standard warranty is 24 months from date of shipment. Extended warranty is in addition to the two years, for a total of 3, 4, or 5 years. Refer to Publication 3223 for warranty terms and conditions.
Contact Information
For more details, please contact customercare@ascopower.com
ASCO Power Technologies - Global Headquarters
160 Park Avenue
Florham Park, NJ 07932
Tel: 800 800 ASCO
Website: www.ascopower.com