FCC RF Test Report

WBU ation Depr.

Test Report-2A4DH-5688 FCC RF Spot Check Evaluation Report r4

Amazon.com Services LLC 5688 2A4DH-5688 2A4DH5688 5688

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7489345
FCC RF Test Report

Report No. : 391903-04A

Spot Check Evaluation

APPLICANT EQUIPMENT MODEL NAME FCC ID STANDARD
TEST DATE(S)

: Amazon.com Services LLC : Electronic Display Device : SA568B : 2A4DH-5688 : 47 CFR Part 15 Subpart C §15.247
47 CFR Part 15 Subpart E §15.407 : Jan. 04, 2024 ~ Jun. 19, 2024

We, Sporton International Inc. (Kunshan), would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards.
The test results in this report apply exclusively to the tested model / sample. Without written approval of Sporton International Inc. (Kunshan), the test report shall not be reproduced except in full.

Approved by: Jason Jia
Sporton International Inc. (Kunshan)
No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 1 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

TABLE OF CONTENTS
REVISION HISTORY..........................................................................................................................................3
1 GENERAL DESCRIPTION..........................................................................................................................4
1.1 Applicant ............................................................................................................................................ 4 1.2 Product Feature of Equipment Under Test........................................................................................4 1.3 Modification of EUT ........................................................................................................................... 4 1.4 Testing Site ........................................................................................................................................ 4 1.5 Test Software.....................................................................................................................................5 1.6 Applicable Standards.........................................................................................................................5 2 RE-USE OF MEASURED DATA.................................................................................................................6
2.1 Introduction Section ........................................................................................................................... 6 2.2 Model Difference Information ............................................................................................................ 6 2.3 Reference detail Section: .................................................................................................................. 6 2.4 Spot Check Verification Data Section................................................................................................7 3 AUTOMATICALLY DISCONTINUE TRANSMISSION .............................................................................10
4 LIST OF MEASURING EQUIPMENT........................................................................................................12
5 MEASUREMENT UNCERTAINTY ............................................................................................................13

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 2 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

REVISION HISTORY

REPORT NO. VERSION

DESCRIPTION

ISSUED DATE

391903-04A Rev. 01 Initial issue of report

Jun. 06, 2024

391903-04A Rev. 02 Updated details in Section 2.3 on Page 6

Jun. 17, 2024

391903-04A Rev. 03 Added Automatically Discontinue Transmission test data Jun. 20, 2024

391903-04A Rev. 04 Updated model name

Jul. 03, 2024

Conformity Assessment Condition:
1. The test results (PASS/FAIL) with all measurement uncertainty excluded are presented against the regulation limits or in accordance with the requirements stipulated by the applicant/manufacturer who shall bear all the risks of non-compliance that may potentially occur if measurement uncertainty is taken into account.
2. The measurement uncertainty please refer to each test result in the section "Measurement Uncertainty"
Disclaimer:
The product specifications of the EUT presented in the test report that may affect the test assessments are declared by the manufacturer who shall take full responsibility for the authenticity.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 3 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

1 General Description
1.1 Applicant
Amazon.com Services LLC 410 Terry Avenue N Seattle, WA 98109-5210 United States

1.2 Product Feature of Equipment Under Test

Product Feature

Equipment

Electronic Display Device

Model Name FCC ID

SA568B 2A4DH-5688

SN Code

Conducted: PN43L901350201K2 Radiation: GN433X0434960076/PN43LB0134850473 DFS: GN43H203417400L1

Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications

or user's manual for more detailed description.

1.3 Modification of EUT
No modifications are made to the EUT during all test items.

1.4 Testing Site

Sporton International Inc. (Kunshan) is accredited to ISO/IEC 17025:2017 by American Association for

Laboratory Accreditation with Certificate Number 5145.02.

Test Firm

Sporton International Inc. (Kunshan)

Test Site Location Test Site No.

No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China TEL : +86-512-57900158

Sporton Site No.
03CH08-KS TH01-KS DFS01-KS

FCC Designation No. CN1257

FCC Test Firm Registration No.
314309

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 4 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

1.5 Test Software
Item Site 1. TH01-KS 2. 03CH08-KS

Manufacturer Tonscend AUDIX

Name
JS1120-3 test system China_210602
E3

Report No. : 391903-04A
Version 3.3.10 210616

1.6 Applicable Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:
 FCC KDB 484596 D01 Referencing Test Data v02r02  47 CFR Part 15 Subpart C §15.247  47 CFR Part 15 Subpart E §15.407  ANSI C63.10-2013  ANSI C63.26-2015

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 5 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

2 Re-use of Measured Data
2.1 Introduction Section
This application re-uses data collected on a similar device. The subject device of this application (Model: SA568B, FCC ID: 2A4DH-5688) is electrically identical to the reference device (Model: SA569P, FCC ID: 2A4DH-5698) for the portions of the circuitry corresponding to the data being re-used. Based on their similarity, the FCC Part 15C (equipment class: DTS, DSS) and FCC Part 15E (equipment class: NII) referencing the original model's result and do spot-check, following the FCC KDB 484596 D01 Referencing Test Data v02r02.
The applicant takes full responsibility that the test data as referenced in this report represent compliance for this FCC ID: 2A4DH-5688 .
2.2 Model Difference Information
The main difference between FCC ID: 2A4DH-5698 and FCC ID: 2A4DH-5688 is as below:  Remove WPT.
Other differences and all the details of similarity and difference can be found in the confidential documents (SA568B_Operational Description of Product Equality Declaration).

2.3 Reference detail Section:

Rule Equipment Part Class

DSS (BR/EDR)

15C

DTS (BLE)

DTS (WLAN)

15E U-NII

Frequency Band (MHz)
2400~2483.5
2400~2483.5
2400~2483.5
5180~5240
5260~5320
5500~5720
5745~5825

Reference Type Grant/

FCC ID Permissive

(Parent)

Change

Reference Title

FCC ID Filling (Variant)

2A4DH-5698

Original Grant

FR391903-01A 2A4DH-5688

2A4DH-5698

Original Grant

FR391903-01B 2A4DH-5688

2A4DH-5698

Original Grant

FR391903-01C 2A4DH-5688

2A4DH-5698

Original Grant

FR391903-01D 2A4DH-5688

2A4DH-5698

Original Grant

FR391903-01D 2A4DH-5688

2A4DH-5698

Original Grant

FR391903-01D 2A4DH-5688

2A4DH-5698

Original Grant

FR391903-01D 2A4DH-5688

Report Title/Section
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 6 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

2.4 Spot Check Verification Data Section
Conducted power test and radiated spurious emission test against the variant model based on the worst-case condition from the original model was performed in this filing to demonstrate the test data from original model remains representative for the variant model. All test procedures follow the related section of parent report.

Spot-check measurements, while being always compliant with the applicable rule part(s) for the test

under consideration, show a deviation ddB from the reference data no larger than 3 dB:

ddB = | VdB ­ RdB |  3 dB

(1)

VdB, the variant spot-check level

RdB, the corresponding measurement level for the reference model

An alternative to the limit of eq. (1) is available, and is based on considering how far the reference data

RdB is from the compliance threshold CdB (also expressed in dB), for the particular test under consideration. In this case, if dB =|CdB ­ RdB| is the margin in dB from the compliance limit, a spot

check may be considered acceptable when the deviation ddB from the reference data satisfies the

following condition:

ddB = | VdB ­ RdB |  (3 + dB /20) dB , for 0  dB  60 dB

(2)

ddB = | VdB ­ RdB | = 6 dB where "| |" is the absolute value of the measured quantity.

, for dB60 dB

When using the option in eq. (2), ddB increases linearly from 3 dB to 6 dB.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 7 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

Summary for power and RSE spot check for each rule entry and technology is listed as below:

Test Item Mode

2A4DH-5698 Parent
Worst mode Test Result

2A4DH-5688 Variant
Check Test Result

Deviation (dB)

BT BR/EDR

7.10

7.02

-0.08

BLE 1M

-1.54

-1.76

-0.22

BLE 2M

-1.24

-1.46

-0.22

2.4G 11b

16.68

16.21

-0.47

2.4G 11g

14.96

14.48

-0.48

2.4G 11n20

14.38

13.95

-0.43

5G 11a UNII-1

15.00

14.82

-0.18

5G 11a UNII-2A

14.96

14.72

-0.24

5G 11a UNII-2C

14.72

14.69

-0.03

5G 11a UNII-3

14.66

14.56

-0.1

5G 11n20 UNII-1

14.79

14.72

-0.07

5G 11n20 UNII-2A

14.91

14.82

-0.09

5G 11n20 UNII-2C

14.83

14.78

-0.05

Conducted Power (dBm)

5G 11n20 UNII-3 5G 11n40 UNII-1 5G 11n40 UNII-2A 5G 11n40 UNII-2C

14.65 14.85 14.83 14.71

14.41 14.61 14.78 14.56

-0.24 -0.24 -0.05 -0.15

5G 11n40 UNII-3

14.61

14.54

-0.07

5G 11AC20 UNII-1

14.61

14.55

-0.06

5G 11AC20 UNII-2A

14.85

14.63

-0.22

5G 11AC20 UNII-2C

14.72

14.61

-0.11

5G 11AC20 UNII-3

14.61

14.38

-0.23

5G 11AC40 UNII-1

13.63

13.51

-0.12

5G 11AC40 UNII-2A

13.89

13.73

-0.16

5G 11AC40 UNII-2C

13.73

13.54

-0.19

5G 11AC40 UNII-3

13.56

13.45

-0.11

5G 11AC80 UNII-1

13.38

13.26

-0.12

5G 11AC80 UNII-2A

13.56

13.38

-0.18

5G 11AC80 UNII-2C

13.46

13.39

-0.07

5G 11AC80 UNII-3

13.36

13.29

-0.07

Limit (dB)
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

Test Item
Radiated Spurious Emission (dBm)

Mode
Bluetooth BR/EDR Bluetooth LE 2Mbps 2.4G 11g 5G 11n HT40 5G 11n HT20

2A4DH-5698 Parent
Worst Result 55.73
44.78 50.52 50.79
59

2A4DH-5688 Variant
Check Result 54.93
44.7 48.29 47.88 57.75

Deviation (dB)
-0.8 -0.08 -2.23 -2.91 -1.25

Limit (dB)
3 3 3 3 3

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 8 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

Conclusion: Radiated spurious emission test against the variant model based on the worst-case condition from the original model was performed in this filing to demonstrate the test data from original model remains representative for the variant model.
Based on the spot check test result, the test data from the original model is representative for the variant model. The power level and RSE spot check are shown within expected level compliant to limit line.
We are using power measurements from the original parent model reports to list on the grant.
We confirm that the test data referencing policy of FCC KDB 484596 D01 Referencing Test Data v02r02 has been followed and the test data as referenced from the parent model report represents compliance with new FCC ID.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 9 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

3 Automatically Discontinue Transmission
3.1.1 Limit of Automatically Discontinue Transmission
The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. These provisions are not intended to preclude the transmission of control or signaling information or the use of repetitive codes used by certain digital technologies to complete frame or burst intervals. Applicants shall include in their application for equipment authorization to describe how this requirement is met.
3.1.2 Measuring Instruments
The measuring equipment is listed in the section 4 of this test report.
3.1.3 Test Result of Automatically Discontinue Transmission
EUT is verified this characteristic during the function check of normal sample associated with an access point: A. Information start: make EUT supply information to the access point. B. Information stop: stop supplying information to the access point. While the EUT is not transmitting any information, the EUT can automatically discontinue transmission and become standby mode for power saving. C. Information start: make EUT supply information to the access point again. The EUT can detect the controlling signal of ACK message transmitting from remote device and verify whether it shall resend or discontinue transmission.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 10 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report
5180MHz
B

Report No. : 391903-04A

A Stop
5745MHz

C Start

B

A Stop

Start

C

Note: The control / signaling information during the period B is precluded.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 11 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

4 List of Measuring Equipment

Instrument Manufacturer

EMI Test Receiver
Spectrum Analyzer
Loop Antenna

Keysight R&S R&S

Model No. N9038A FSV40
HFH2-Z2E

Serial No. Characteristics

Calibration Date

MY564000 3Hz~8.5GHz;M

23

ax 30dBm

Jan. 05, 2023

101932

10kHz~40GHz; Max 30dBm

Oct. 10, 2023

101125 9kHz~30MHz Oct. 10, 2023

Bilog Antenna TESEQ& VGT CBL 61110

Double Ridge Horn Antenna

ETS-Lindgren

3117

high gain Amplifier

EM

EM01G18GA

59915 75959 060845

30MHz-1GHz Aug. 12, 2023 1GHz~18GHz Mar. 18, 2023 1Ghz-18Ghz Jan. 05, 2023

SHF-EHF Horn Com-power

AH-840

101070 18GHz~40GHz Jan. 08, 2023

Amplifier

SONOMA

310N

413741 9KHz-1GHz Jan. 05, 2023

Amplifier Amplifier AC Power Source Turn Table

EM MITEQ Chroma
EM

EM01G18GA 060834 1Ghz-18Ghz

EM18G40GG A

060728

61601

616010002 473

18~40GHz N/A

EM 1000-T

N/A

0~360 degree

Oct. 10, 2023 Jan. 05, 2023
NCR NCR

Antenna Mast
Spectrum Analyzer Pulse Power
Senor
Power Meter
Spectrum Analyzer

EM R&S Anritsu Anritsu R&S

EM 1000-A

N/A

1 m~4 m

NCR

FSV40 MA2411B ML2495A
FSV7

101040 10Hz~40GHz Oct. 11, 2023

0917070 1005002

300MHz~40GH z
50MHz Bandwidth

Jan. 02, 2024 Jan. 02, 2024

101632 10Hz~7GHz Jan. 03, 2024

Test Date Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Jan. 04, 2024 Mar. 06, 2024 Mar. 06, 2024 Mar. 06, 2024 Jun. 19, 2024

Due Date Jan. 04, 2024 Oct. 09, 2024 Oct. 09, 2024 Aug. 11, 2024 Mar. 17, 2024 Jan. 04, 2024 Jan. 07, 2024 Jan. 04, 2024 Oct. 09, 2024 Jan. 04, 2024
NCR NCR NCR Oct. 10, 2024 Jan. 01, 2025 Jan. 01, 2025 Jan. 02, 2025

Remark
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Radiation (03CH08-KS)
Conducted (TH01-KS) Conducted (TH01-KS) Conducted (TH01-KS)
DFS (DFS01-KS)

NCR: No Calibration Required.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 12 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 391903-04A

5 Measurement Uncertainty
The measurement uncertainties shown below were calculated in accordance with the requirements of ANSI 63.26-2015. All the measurement uncertainty value were shown with a coverage K=2 to indicate 95% level of confidence. The measurement data show herein meets or exceeds the CISPR measurement uncertainty values specified in CISPR 16-4-2 and can be compared directly to specified limit to determine compliance.

Uncertainty of Conducted Measurement Test Item
Conducted Power

Uncertainty ±0.46 dB

Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz)

Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

6.28 dB

Uncertainty of Radiated Emission Measurement (1 GHz ~ 18 GHz)
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

4.90 dB

Uncertainty of Radiated Emission Measurement (18 GHz ~ 40 GHz)

Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

5.26 dB

-THE END-

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 13 of 13

Report Issued Date : Jul. 03, 2024

Report Version

: Rev. 04

Report Template No.: SCE Version 1.0


Microsoft Word 2010 Microsoft Word 2010