Metrix™ Reader Quick Start Guide
Aptitude Medical Systems, Inc.
Start Here
[QR code for interactive instructions and video demonstration]
01 Power Up
Connect reader to power supply. The center light will turn solid (not flashing) when ready.
02 Collect Sample
Open the Metrix COVID-19 Test kit (available separately) if you have not done so already. The Metrix COVID-19 Test kit will guide you through how to collect and run your sample.
For use with the Metrix COVID-19 Test kit (available separately). For use under Emergency Use Authorization (EUA) only.
Reader Statuses
Starting Up
The reader is starting up. Wait until the center light is solid white before inserting a sensor.
Ready
The reader is ready to start a test.
Test Running
The reader is running a test. DO NOT remove the sensor or unplug the reader.
Positive Result
The test is complete and SARS-CoV-2 was detected in the sample.
Negative Result
The test is complete and SARS-CoV-2 was NOT detected in the sample.
Invalid Result
The test is complete and the result is invalid. Repeat with a new Metrix COVID-19 Test kit.
[Flashing light indicator]
Troubleshooting
Test Error
Remove sensor and firmly press down on collector. Firmly reinsert sensor into reader. If error persists, discard sensor and use a new test kit.
No Power
Check all electrical connections. The reader is not receiving power.
Canceled Test
The test did not complete. Discard the sensor and run the test with a new test kit.
Hardware Failure
There is an error with the reader. Disconnect and reconnect the power.
If troubleshooting fails to resolve any problem, please contact support.
If your Metrix Reader needs to be disposed of, please place in electronic waste. ♻️ [Dispose in electronic waste]
For support, please contact Aptitude Medical Systems at: 1.888.934.2253 or support@aptitudemetrix.com. Or visit: AptitudeMetrix.com.
Legend of Symbols
- IVD: For vitro diagnostic use
- ? [Power plug symbol]: No Power
- ❌ [Canceled test symbol]: Canceled Test
- ⚙️ [Hardware failure symbol]: Hardware Failure
- ⚡ [Flashing light symbol]: Indicates flashing light
- DC [Direct Current voltage symbol]: Direct current (DC) voltage
- ⛨️ [Manufacturer symbol]: Manufacturer of device
- ?️ [Temperature limitations symbol]: Temperature limitations of the product
- ? [Date of manufacture symbol]: Date of manufacture
- ? [Keep dry symbol]: Keep dry
- REF: Manufacturer's catalog number
- ℹ️ [Consult instruction manual symbol]: Please consult the instruction manual
- ♻️ [Dispose electronic waste symbol]: Dispose of in electronic waste
- FC [FCC compliant symbol]: Certification that the electromagnetic interference from the device is under limits approved by the Federal Communications Commission.
Warnings and Precautions
- Do not use components that are visibly damaged.
- The Metrix Reader can be cleaned by wiping the exterior with disinfectant. Do not spray disinfectant into or onto the reader.
- If a power failure occurs or if the Metrix Reader is unplugged while the Sensor is inserted, the test result is invalidated. The test should be redone with a new test kit.
- Use only the provided power cable and power adapter.
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FDA Emergency Use Authorization (EUA)
The Metrix COVID-19 Test kit and Metrix Reader are for FDA Emergency Use Authorization (EUA) only. This home test kit is only authorized for the duration of the declaration that circumstances exist justifying the authorization of emergency use of IVDs for detection and/or diagnosis of COVID-19 under Section 564(b)(1) of the Federal Food, Drug, and Cosmetic Act, 21 U.S.C. § 360bbb-3(b)(1), unless the authorization is terminated or revoked sooner.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note 1
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note 2
Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.