This manual will enable you to properly install your Automatic Gate Operator. The gate operator is designed for installation on a pull-to-open single leaf gate. By purchasing two accessory brackets [347IH], the gate operators can accommodate push-to-open gates (gates that open out from the
All automatic gate openers are intended for use on vehicular gates only. Installation Manual. FM502. This product meets and exceeds the ...
This manual will enable you to properly install your Automatic Gate Operator. The gate operator is designed for installation on a pull-to-open single leaf gate.
Installation Manual FM502 WARNING! This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO Access Systems, LLC, shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO Access Systems, LLC, from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value. READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate opener. This gate opener produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times. All automatic gate openers are intended for use on vehicular gates only. This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, by Underwriters Laboratories Inc. For more information on Mighty Mule's full line of Automatic Gate Openers and Access Controls visit our website at www.mightymule.com GTO Sales: 800-543-4283 · Fax 850-575-8912 GTO Technical Service 800-453-1236 For 24 hour/day, 7 day/week Technical Service visit http://support.gtoinc.com For more information on Mighty Mule's full line of Automatic Gate Openers and Access Controls visit www.mightymule.com Printed in China for GTO Access Systems, LLC. Copyright© 2015 GTO Access Systems, LLC rev 12.14.15 U.L. Gate Operator Classifications Residential Vehicular Gate Operator--Class I: A vehicular gate operator (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith. Commercial/General Access Vehicular Gate Operator--Class II: A vehicular gate operator (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public. Industrial/Limited Access Vehicular Gate OperatorClass III: A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. Restricted Access Vehicular Gate OperatorClass IV: A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. Product Usage The GTO Gate Operator meets all of the safety requirements of a Class I Residential Vehicular Gate Operator and is intended for use solely with vehicular swing gates in single-family residential applications. The GTO Gate Operator system certified to be in compliance with the following safety standards (current edition as of publication date): Product in compliance with the latest UL-325 and UL-991 safety standards by ETL. Product in compliance with CAN/CSA-C22.2 No. 247-92. Product in compliance with IEC 60335-2-103:2003 and IEC 60335-1:2004, including A1:2004. Converting Metric Units to English Equivalents When You Know Multiply By To Find centimeters meters kilograms 0.3937 3.2808 2.2046 inches feet pounds Converting English Units to Metric Equivalents When You Know Multiply By To Find inches feet pounds 2.5400 0.3048 0.4535 centimeters meters kilograms Converting Temperature deg. Celsius (°C x 1.8) + 32 deg. Fahrenheit (°F-32) ÷ 1.8 deg. Fahrenheit deg. Celsius Symbol in. (or ") ft. (or ') lb. (or #) Symbol cm m kg °F °C FOR YOUR RECORDS Please record the following information product serial number (located on right side of control box), be sure to keep all receipts for proof of purchase. Refer to this information when calling GTO for service or assistance with your automatic gate opener. Serial Number:____________________________________ Date of Purchase:_________________ Place of Purchase:____________________________________________________________________ KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Table of Contents Gate Opener Class Categories--------------------------------------------------------------inside cover Units and Standards Conversion Chart----------------------------------------------------inside cover PLEASE READ THIS FIRST!---------------------------------------------------page iii Important Safety Instructions ---------------------------------------------------page 1 Disconnecting the Opener--------------------------------------------------------------page 1 Important Safety Instructions for the Consumer-------------------------------------page 2 Secondary Means of Protection Against Entrapment-------------------------------page 5 Required Safety Precautions for Gates------------------------------------------------page 6 Warning Signs and Labels--------------------------------------------------------------page 7 Installation ---------------------------------------------------------------------------page 8 Parts List----------------------------------------------------------------------------------page 8 Technical Specifications --------------------------------------------------------------page 10 Installation Overview -------------------------------------------------------------------page 11 Installation of the Mounting Hardware-----------------------------------------------page 12 Mounting the First Opener-------------------------------------------------------------page 16 Installing the Second Opener-----------------------------------------------------------page 16 Installation of the Closed Position Stops---------------------------------------------page 17 Mounting the Control Box--------------------------------------------------------------page 19 Connecting the Opener Power Cables------------------------------------------------page 20 Powering the System ---------------------------------------------------------------page 21 Solar Chart--------------------------------------------------------------------------------page 21 Connecting the Transformer------------------------------------------------------------page 23 Control Board Settings -----------------------------------------------------------page 24 Setting Closed Position Limits---------------------------------------------------------page 25 Setting Your Personal Transmitter Code --------------------------------------page 26 Obstruction Sensitivity------------------------------------------------------------------page 27 Installing the Receiver ------------------------------------------------------------page 27 Connecting Accessories -----------------------------------------------------------page 28 Wiring Accessories -----------------------------------------------------------------page 29 Push to Open Installation ---------------------------------------------------------page 30 Setting Open Position Limits-----------------------------------------------------------page 31 Troubleshooting Guide -----------------------------------------------------------page 33 Repair Service ----------------------------------------------------------------------page 35 Column Installation Information -----------------------------------------------page 36 Accessory Catalog -----------------------------------------------------------------page 37 PLEASE READ THIS FIRST! Thank you for purchasing a GTO ACCESS SYSTEMS gate opener. When correctly installed and properly used, your gate operator will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your Automatic Gate Operator. The gate operator is designed for installation on a pull-to-open single leaf gate. By purchasing two accessory brackets [347IH], the gate operators can accommodate push-to-open gates (gates that open out from the property). The gates must not exceed 18 feet in length nor weigh more than 850 pounds per leaf (please see Technical Specifications on page 10). The gate operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the operator will obstruct, stop, and blow fuses. The gate operator accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories are shown in the back of this manual. The gate operator features adjustable stall force. This safety feature makes the gate stop and reverse direction within two seconds when it comes in contact with an obstruction. The "MIN" setting means the gate will exert the minimum force on an obstruction before it stops and reverses direction. The gate operator also has an adjustable auto-close feature. It can be set to remain open from 3 to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate fully opens will cause it to close immediately. "OFF" is the factory setting; meaning the gate will stay open until you press the transmitter button (or keypad, etc.) again. Please call GTO at (800) 543-4283 for more information about our GTO ACCESS SYSTEMS professional line of gate operators and accessories. BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR: Read these instructions carefully and completely to become familiar with all parts and installation steps. You must read the installation manual for detailed instructions on gate operator safety and proper use of the gate operator. 24/7 Troubleshooting Wizard: http://support.gtoinc.com iii IMPORTANT SAFETY INSTRUCTIONS Because automatic gate openers produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate opener systems. Keep in mind that the gate opener is just one component of the total gate operating system. Each component must work in unison to provide the consumer with convenience, security, and safety. This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate opener, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT. Precautions and warnings in this manual are identified with this that can result in damage to the opener or its components, serious warning symbol. The symbol identifies conditions injury, or death. Because GTO automatic gate openers are only part of the total gate operating system, it is the responsibility of the consumer to ensure that the total system is safe for its intended use. To Manually Open and Close the Gate, Follow the Procedure Below: CAUTION: The gate will move freely and uncontrolled when the gate opener is removed from the gate. ONLY disconnect the opener when the control box power switch is OFF and the gate is NOT moving. Disconnecting the Opener 1. Turn control box power switch OFF. 2. Remove hairpin clip, clevis pin, and bushing from either the front or rear mounting point. 3. Remove the opener from the mount. The gate can be opened and closed manually when the opener is disconnected. Front Mount Clevis Pin Gate Bracket Bushing Hairpin Clip NOTE: Substitute a included Pin Lock for the clevis pin on the front mount of each gate opener to prevent unauthorized removal of the opener from the gate. 1 IMPORTANT SAFETY INSTRUCTIONS For The Consumer WARNING: To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual could cause severe injury or death, for which the manufacturer cannot be held responsible. 2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion. 3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas. 4. The gate and gate opener installation must comply with any applicable local codes. I. Before Installation 1. Verify this dual opener is proper for the type and size of gate, its frequency of use and the proper class rating. 2. Make sure the dual gate has been properly installed and swings freely in both directions. Repair or replace all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance the performance of the opener and safety devices used with the system. (see page 11) 3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the opener for manual gate operation (see page 1). 4. This gate opener is intended for vehicular gates ONLY. A separate entrance or gate must be installed for pedestrian use (see page 6). 5. Always keep people and objects away from the gate and its area of travel. NO ONE SHOULD CROSS THE PATH OF A MOVING GATE. 6. Pay close attention to the diagram below and be aware of these areas at all times. ZONE 2 ZONE 1 ZONE 2 ZONE 5 ZONE 4 ZONE 3 Driveway ZONE 3 Gate in the Open Position Entrapment Zones for a Pull-To-Open Application 2 ZONE 5 ZONE 4 Gate in the Open Position IMPORTANT SAFETY INSTRUCTIONS Entrapment Zones for a proper Pull-To-Open installation: Zone 1 leading edge of the gate and the fence post. Zone 2 between the gate and the gate post. Zone 3 the path of the gate. Zone 4 the space between the gate in the open position and any object such as a wall, fence, tree, etc. Zone 5 pinch points between the opener and gate. II. During Installation 1. Install the gate opener on the inside of the property and fence line. DO NOT install an opener on the outside of the gate where the public has access to it. 2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched. 3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional protection against entrapment. 4. If push buttons or key switches are installed, they should be within sight of the gate, yet located at least 10 feet from any moving part of the gate (see diagram below). Never install any control device where a user will be tempted to reach through the gate to activate the gate opener. 5. Do not activate your gate opener unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions. Watch the gate through its entire movement. 6. Secure outdoor or easily accessed gate opener controls in order to prohibit unauthorized use of the gate. Pull-To-Open Application 10' 10' 10' 10' Moving Gate Moving Gate Area Area Driveway NEVER INSTALL 10' any control device within gray area 10' 3 IMPORTANT SAFETY INSTRUCTIONS III. After Installation 1. Attach the warning signs (included) to each side of the gate to alert the public of autom atic gate operation. It is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements. 2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with the gate when it is moving or stationary. 3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop. 4. Do not attempt to "beat the gate" (drive through) while the gate is closing. This is extremely dangerous. 5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep the remote controls away from children and unauthorized users; store controls where children and unauthorized users do not have access to them. 6. KEEP GATES PROPERLY MAINTAINED. Always turn power to opener OFF before performing any maintenance. Clean the push-pull tube, spray a soft dry cloth with silicone spray and wipe the tube at least once per month. 7. Service the gate and gate opener regularly. Grease hinges, and replace the battery every 2-3 years. 8. To operate this equipment safely, YOU must know how to disconnect the opener for manual gate operation (see page 1). If you have read the instructions and still do not understand how to disconnect the opener, contact the GTO Service Department. 9. Disconnect the opener ONLY when the power is TURNED OFF and the gate is NOT moving. 10. Make arrangements with local fire and law enforcement for emergency access. 11. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS section of this manual with all persons authorized to use your gate. 12. IMPORTANT: Save these safety instructions. Make sure everyone who is using or will be around the gate and gate opener are aware of the dangers associated with automated gates. In the event you sell the property with the gate opener or sell the gate opener, provide a copy of these safety instructions to the new owner. Should you lose or misplace this manual, a copy can be obtained by downloading one from the GTO® Access Systems web site (www.gtoaccess. com), by contacting GTO, at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge. 4 IMPORTANT SAFETY INSTRUCTIONS Secondary Means of Protection Against Entrapment As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary means to protect against entrapment. GTO gate openers utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. Also, the gate opener has provisions for the connection of Type B1 or B2 protection to be used as the secondary type of entrapment protection, if desired. 1. For gate operators utilizing a non-contact sensor (e.g., photo-electric sensor Type B1) in accordance with UL 325 (51.8.4 [h]): A. Refer to the sensor manufacturer's instructions on the placement of non-contact sensors for each type of application. B. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving. C. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. 2. For gate operators utilizing a contact sensor (e.g., safety edge sensor Type B2) in accordance with UL 325 (51.8.4 [i]): A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and outside of a vehicular swing gate system. B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions. You may want to consider adding photo beams to your installation. GTO Photo Beams [R4222] provide a "non contact" means of entrapment protection. Leading Edge Contact Sensor on both sides of the gate Vehicular Gate Vehicular Gate 500 ® E-Z GATE OPENER UL325 SERIES 1-800-543-GATE (4283) www.mightymule.com Post Edge Contact Sensor on both sides of the gate Bottom Edge Contact Sensor on both sides of the gate Post Edge Contact Sensor on both sides of the gate ENTRAPMENT ALARM (UL 325; 30A.1.1A) The GTO® Gate Opener is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these openers are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the opener receives an intended signal from a hard wired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm. 5 IMPORTANT SAFETY INSTRUCTIONS Required Safety Precautions for Gates Install Warning Signs Warning signs alert people of automatic gate operation and are required when installing the GTO® gate opener. Furthermore, a walk-through gate must be installed if pedestrian traffic is expected near the vehicular gate. We recommend using the GTO Bulldog Pedestrian Gate Lock (Call the GTO Sales Department at 1-800-543-4283) for controlled access. Bulldog Pedestrian Gate Lock (recommended, not included) Pedestrian Gate Warning Sign Contact Sensor (recommended, not included) Warning Sign Vehicular Gate Vehicular Gate Contact Sensor (recommended, not included) Contact Sensor (recommended, not included) Contact Sensor (recommended, not included) Entrapment Protection GTO's inherent obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily injury in some circumstances. For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment. Warning Signs The warning signs (at right) must be installed on both sides of the gates (see page 7 for details). ! WARNING Moving Gate Can Cause Injury Or Death 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance. 6 IMPORTANT SAFETY INSTRUCTIONS ! These warning labels should be found at the locations specified below. If any of them are missing, immediately contact GTO for replacements. DC SWING SERIES / 500 Conforms to UL 325 STANDARDS Maximum Gate: 500 lb. (226.7 kg); 16 ft. (4.8 m) C US Voltage: 12 Vdc; Frequency: 0 Hz; Power: 25 W LISTED #xxxxxxx Class I, II, III and IV Vehicular Swing Gate Operator. Serial Number: XXXXXXXXXX TO MANUALLY OPEN AND CLOSE THE GATE: 1. Turn control box power switch OFF. 2. Disconnect front or rear mount from gate bracket. 3. Pull opener away from front or rear mount. Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving. GTO Access Systems, LLC · Tallahassee, Florida USA Product identification and manual operation instruction label (1) installed on the right side of the control box. Warning signs (2 enclosed) to be installed on each side of the gate (35 feet above the bottom of the gate) ®502 E-Z GATE ®OPENER UL325 SERIES Logo and warning labels (2) installed on each side of opener housing 7 Dual Gate Opener Parts List Opener and Mounting Hardware ® E-Z GATE OPENER Customer Support Card (1) Installation Video (1) 502 ® UL325 SERIES E-Z GATE OPENER 1-800-543-GATE (4283) · www.mightymule.com ! WAMROVNINIGNGAG TE Can Cause Injury or Death 123...KDTEohEinsPogCtaaLtleEloAiswRf!coGhriavldteerheminclateoysmooponelvyre.aPtaetegdaanetysettroiimarneps.lamyuinstguastee area. separate entrance. Gate Opener (1) w/ 6' Power Cable Gate Opener (1) w/ 32' Power Cable 502 E-Z GATE OPENER® UL325 SERIES 1-800-543-GATE (4283) · www.mightymule.com ! WAMROVNINIGNGAG TE Can Cause Injury or Death 123...KDTEohEinsPogCtaaLtleEloAiwsRf!coGhriavldteerhemincalteyosmooponevlyrea. tPaetegadanetysettroiimarneps.lamyuinstguastee area. separate entrance. 8" Nylon Cable Tie (20) Gate Bracket (2) Closed Position Stop Plate (2) Post Bracket (4) Hardware Post Pivot Bracket (2) 3/8" x 8" Bolt (8) 3/8" x 3" Bolt (4) 3/8" x 2" Bolt (2) 5/16" x 1-3/4" Bolt (2) 3/8" x 1-1/2" Clevis Pin (4) Hairpin Clip (4) 8 2" Mounting Screw (5) 3/8" Washer (18) 3/8" Lock Washer (14) 5/16" Washer (2) 3/8" Nut (14) 5/16" Nut (2) 3/8" Bushings (4) Dual Gate Opener Parts List (continued) Control Box and Electrical Components Battery (1) Receiver (1) ! WARNING GTO Transmitter(1) Transformer (1) Control Box (1) Moving Gate Can Cause Injury Or Death 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance. Warning Signs (4) Tools Needed · Power Drill · Open End Wrenches -- 9/16" and 1/2" · Long 3/8" and 5/16" Drill Bit · Hacksaw or Heavy Duty Bolt Cutters · Small (Flat Bladed) Screwdriver · Phillips Screwdriver · Tape Measure · Level · Wire Strippers · C-Clamps -- small, medium, and large · Center Punch · An extra person will be helpful YOU MAY ALSO NEED THESE ITEMS BEFORE YOU BEGIN THE INSTALLATION (Some of these items can be found in the Accessory Catalog page 37): · Low voltage wire will be needed to run from the transformer to the control box; length depends upon the distance between the transformer power supply and the control box. See Powering the System on page 21, and the Accessory Catalog. · If your gate is more than 1000' away from an ac power source you will need to use at least 10 to 30 Watts of solar charging power to trickle charge the battery. See the Accessory Catalog. · If your fence post is made of wood and is less than 6" in diameter or 6" square, see page 12. · If your fence post is larger than 6" in diameter you will need threaded rods or carriage bolts longer than 8". See page 15. · PVC conduit. · If you have thin walled tube or panel gates, see Recommended Reinforcement Examples on page 12. · Depending on the type of gate, a horizontal cross member or mounting plate may be needed to mount the front of the opener and gate bracket to the gate. See page 11, step 2; page 15, step 10. · Surge protection for transformer. · Some types of installations require U-Bolts. · If the gate is a push-to-open refer to page 30 · Additional washers or a metal plate may be needeed for wooden post. 9 Technical Specifications GTO® GATE OPENER DRIVE · Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-28 ºC to +71 ºC). · Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm. · Maximum opening arc of 110º. Approximate opening time (90º): 20 seconds, depending on weight of gate. POWER · The system is powered by two 12 Vdc, 7.0 Ah, sealed, rechargeable acid batteries. · Battery charge is maintained by a18 Vac output transformer rectified to 14.5 Vdc (20 VA) through the GTO control board. One (1) blade-style control board fuse rated for 25 A. NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated fuses; doing so will void your warranty and may damage your control board. · Battery charge is maintained by GTO Solar Panel Charger kit (5 Watt minimum). CONTROL · GTO microprocessor-based control board is set for single leaf, pull-to-open gate installations. DIP switches can be adjusted to accommodate an optional kit for push-to-open gates (see Accessory Catalog). · A circuit on the control board regulates charging. "Sleep draw" is 40 mA; "active draw" is 2 to 5 A. · Auto-memorization of digital transmitter code. · GTO remote-mounted RF receiver tuned to 318 MHz. · Opener length with push-pull tube fully retracted is 401/4", mounting point to mounting point. Max stroke 22". · Adjustable auto-close timer and obstruction sensitivity. · Power terminal bock accommodates a transformer or solar panels. · DIP switches simplify setup of gate opener. · Accessory terminal block is fully compatible with push button controls, digital keypads, safety loops, etc. · Control board allows connection of safety edge sensors and photoelectric sensors. · Audio entrapment alarm sounds if the unit encounters an obstruction twice while opening or closing. OPERATIONAL CAPACITY · The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO® Automatic Gate Opera- tor when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation. NOTE: "NR" indicates this size and weight combination is not recommended for the GTO® gate openers. IMPORTANT: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 Lbs. Gate Weight Mighty Mule 502 Gate Capacity /Cycle Chart Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery. Number of Cycles Per Day 850 lbs. 750 lbs. 650 lbs. 550 lbs. 450 lbs. 350 lbs. 250 lbs. 150 lbs. 100 lbs. 50 lbs. 68 73 78 83 88 93 98 103 108 113 5' - 6' 63 NR NR 68 63 NR 73 68 63 78 73 68 83 78 73 88 83 78 93 88 83 98 93 88 103 98 93 108 103 98 8' 10' 12' Gate Length NR NR NR NR NR NR NR NR NR 63 NR NR 68 63 NR 73 68 63 78 73 68 83 78 73 88 83 78 93 88 83 14' 16' 18' NR = NOT RECOMMENDED To determine the number of cycles the gate opener will perform using solar panels, please see the specifications listed on page 21. * An operation cycle is one full opening and closing of the gate. These specifications are subject to change without notice. 10 Installation Overview Pull-to-Open Gates (Gate Opens into the Property) The diagram shown below is an example of a pull-to-open installation on a chain link fence and dual gates. Mounting the openers on a masonry column requires special procedures; see Column Installation Information on page 38 if you intend to mount the openers on columns. Furthermore, if you have push-to-open gates, you will need to purchase two (2) pushto-open brackets (see Accessory Catalog) to properly configure your system. See Push to Open Installation on page 32 before proceeding. Gate swings evenly and freely hung firmly and plumb Receiver Control box with batteries Post bracket assembly Second gate opener Gate bracket Master gate opener 6' Power cable Closed position plates Concrete poured around gate post PVC conduit (not included) to protect second opener power cable and low voltage wire from lawn mowers and weed eaters. ® 500 E-Z GATE OPENER UL325 SERIES 1-800-543-GATE (4283) www.mightymule.com 120 Volt indoor transformer (surge protector not supplied) Run 1000' (max.) of low voltage wire to control box from transformer (wire not included). Preparation of the Gate Step 1 The gates must be plumb, level, and swing freely on their hinges. Wheels must not be attached to the gates. The gates must move throughout their arc without binding or dragging on the ground. Note that gates over 250 lb. should have ball bearing hinges with grease fittings. Step 2 The fence posts must be secured in the ground with concrete so they will minimize twist or flex when the openers are activated. We recommend you position the openers near the centerline of the gates to keep the gates from twisting and flexing and to avoid backsplash from rainwater. The addition of horizontal or vertical cross members (if they are not already in place) to provide a stable area for mounting the gate brackets is also important. Horizontal Cross Member Vertical Cross Member 11 Installation of Mounting Hardware The position of the post bracket determines the leverage and efficiency of the opener. The post bracket position also sets the clearance between the opener and gate in the open and closed positions (minimum 2 inches). The curved design of the post bracket works well for installations on round and square fence posts. Because the post bracket carries the entire thrust of the active opener, bolts that completely penetrate the fence post must be used. On wooden posts, place a metal plate or washer (not supplied) between the nuts and the fence post to prevent the thrust of the opener from pulling the bolts and washers out of the wood. Wooden Post Metal Plate Wooden Post Metal Plate NOTE: A fence post smaller than 6" in diameter or 6" square should be made of metal instead of wood so that it will remain stable while the opener is moving the gate. Larger than 6" diameter post Center of Gate Hinge Post Bracket Post Pivot Bracket Post Bracket Post Pivot Bracket Post Pivot Bracket Post Bracket Post Bracket Assembly Pull-to-Open Installation On round posts of 6" diameter or larger, the post pivot bracket may not be necessary for the installation. In this instance, the two post brackets are mounted by themselves. IMPORTANT: We strongly recommend using steel pipe, wood or metal to reinforce thin walled tube gates or wood to reinforce panel gates as shown. These reinforcement methods will prevent damage to the opener and gate when the opener is installed. Recommended Reinforcement Examples Muffler Clamp (not supplied) Muffler Clamp for Gate Bracket Thin Walled Tube Gate Gate Bracket Wood or Metal Reinforcement Gate Bracket Wood or Metal Reinforcement (not supplied) Panel Gate 1" x 6" Wood Reinforcement Gate Bracket 1" x 6" Wood Reinforcement 12 Determining the Mounting Position of the Post Bracket Assembly and the Gate Bracket Post Bracket Assembly Step 3 Insert the 3/8" x 2" bolt through the center hole of the post brackets and post pivot bracket as shown. Fasten a 3/8" lock washer, 3/8" washer and 3/8" nut on the end of the bolt. DO NOT overtighten the nut because the post pivot bracket will have to be adjusted later. 3/8" x 11/2" Bolt Post Pivot Bracket Post Bracket 3/8" Washer NOTE: The following steps are intended for pull-to-open gate installations. If you are mounting your gate openers on a push-toopen gate (e.g., a gate on a sloped driveway) you will need to purchase two Push To Open brackets (see Accessory catalog). Also, see Pushto-Open Installation beginning on page 30. 3/8" Lock Nut Step 4 Attach post bracket assembly and gate bracket to the opener with the clevis pins and bushings. Secure the clevis pins with hairpin clips. Clevis Pin Rear Mount Front Mount Bushing Opener Clevis Pin Gate Bracket Hairpin Clip Post Bracket Assembly Bushing Hairpin Clip Post Bracket Assembly Step 5 With the gate in the open position (up to 110º from its closed position) and the gate opener arm fully retracted, adjust the post bracket assembly and gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily secure the post braLcekveetlaOsspeemnbelry and gate bracket to the fence post and gate. LEVEL horizontal cross member Fence Post Gate In Open Position Gate Bracket 13 IMPORTANT: While determining the mounting point for the post pivot bracket assembly, be sure that the position allows for minimum 2 inches of clearance between the gate and the opener in both the open and closed positions, as shown in the diagrams below. This clearance will give the opener the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. Step 6 When you feel that you have the best position for the post pivot bracket in the open position, insert the 5/16" x 1-3/4" bolt through the aligned holes of the post bracket and post pivot bracket to hold it in place. Remove the clevis pin from the front mount and while supporting the gate opener, swing the gate and gate opener to the closed position. With the gate and gate opener in the closed position check the clearance and be sure that the gate opener is not binding at the post pivot bracket. If you don't have 2 inches of clearance or the gate opener is binding on the post pivot bracket, remove the 5/16" x 1-3/4" bolt and readjust the pivot bracket until you can achieve these important clearances. Gate in the With the post bracket in the pivot open pborascitki2oe"tnimanntidhneriemocphuteimmckutmhepCgoasLtietiOoonpSefnoEer rDclleevaPrealOnacnSedIamTndaIkOfereNseudroemthoefbmraocvkeemtseanrte, reattach the opener clamped securely. to the gate Pinch Area Be sure gate opener and bracket don't bind. Pinch Area Gate in the OPENED POSITION 2" minimum TIP: Turning the pivot bracket over gives more hole alignment options for the post pivot bracket assembly. You can also move the entire post pivot bracket assembly to different positions on the gate post to help achieve the proper clearances. 14 Installing the Post Bracket Assembly and Gate Bracket Step 7 Mark reference points for bolt holes on the fence post through middle of bracket slots. Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots. After marking your reference points, remove the opener and brackets from the fence and gate. Step 8 Drill 3/8" holes into fence post as marked. Step 9 Fasten post bracket assembly to the fence post using (4) 3/8" x 8" bolts, washers, lock washers, and nuts (provided). NOTE: In cases where the fence post has a diameter larger than 6", threaded rods or carriage bolts longer than 8" (not supplied) must be used. Mark fence post through middle of bracket slots and drill 3/8" holes Post Bracket Assembly SIDE VIEW EXAMPLES TOP VIEW Round Metal Post Square Metal Post Square Wood Post Step 10 Drill 3/8" holes into the gate cross member as marked. Mount gate bracket using (2) 3/8" x 2-3/4" bolts, washers, lock washers, and nuts (provided). NOTE: After the gate opener installation is complete and operation of the opener system has been tested, you should remove excess bolt length extending beyond the tightened nuts with a hacksaw or bolt cutters. Remove excess bolt length with hacksaw or bolt cutters Round Wood Post Gate In Open Position LEVEL horizontal cross member Mark cross member through middle of gate bracket slots and drill 3/8" holes Gate Bracket Mounting Examples FRONT VIEW SIDE VIEW Round Tube & Chain Link Gate FRONT VIEW SIDE VIEW Mounting Plate Created for Decorative Gate (required but not supplied) Square Tube Gate Remove excess bolt length with hacksaw or bolt cutters 15 Mounting the Master Opener Step 11 Attach the opener to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin clips, or the Pin Locks (included). Verify that the opener is level and adjust the post bracket assembly if necessary. Post Bracket Assembly bolted to fence post Level Opener LEVEL horizontal cross member Gate Bracket bolted to gate cross member Clevis Pin, Bushing, and Hairpin Clip Fence Post Gate In Open Position Clevis Pin, Bushing, and Hairpin Clip Installing the Second Opener Step 12 Install the second opener on the remaining gate leaf by repeating Step 3 through Step 11, starting on page 13. After you have mounted the second opener, proceed to Installation of the Closed Position Stops on the next page. 16 Installation of the Closed Position Stops The GTO® Gate Openers firmly hold the gates in the closed position using positive stops. The positive stops help stabilize the gate leaves in the closed position. To further enhance stability and security, we strongly recommended using an optional GTO® Automatic Gate Lock (see Accessory Catalog) with your dual gate. IMPORTANT: You need to determine which side of the driveway you will mount the control box. From this point on the gate and gate opener on the same side as the control box will be referred to as the MASTER gate and gate opener. The gate and gate opener on the opposite side of the driveway from the control box will be referred to as the SECOND gate and gate opener. CONTROL BOX Gate Hinge Optional Ground Stop (beneath gate) MASTER GATE Closed Position Stop Plates The gate leaf can open up to 110° (max.) Gate Hinge SLAVE GATE The gate leaf can open up to 110° (max.) Illustration A Step 1 Attach the horizontal closed position stop plate to the MASTER gate leaf. Closed Position Stop Plate mounted horizontally on metal post with U-bolts. Detach the gate operators from the gates and move the gates to their closed position (Illustration A). Using FRONT VIEW appropriate hardware for your type of gate (U-bolts for tube or chain link; screw or bolts for wood or metal) attach the closed position stop plate (horizontally) about mid height on the MASTER gate frame. Do not tighten it completely at this time. Slide the stop plate toward the frame of (Illustration the B). SECOND Once you gate leaf until they touch have moved the stop plate tMo ASTER Gate Frame the correct position, tighten its hardware completely. SLAVE Gate Frame Illustration B TOP VIEW NOTE: The optional ground stop post is used to provide a secure point for the SECOND gate to close against. If you will be using the GTO Horizontal Gate Lock accessory with your gate opener system, the closed position ground stop is REQUIRED, as shown in Steps 2 and 3 on the next page. 17 Step 2 Install a low profile ground stop (not provided) beneath the SECOND gate stop plate. Closed Position Stop Plate mounted on the gate leaf that CLOSES FIRST The ground stop needs to be positioned near the end of the gate as shown in Illustration A and may be made of metal or concrete and should be firmly secured in the ground (we recommend setting it in concrete). Mount Vertically SIDE VIEW Closed Position Stop Plate Low Profile Ground Stop in Near the Center of Driveway Step 3 Attach a vertical closed position stop plate to the SECOND gate. FRONT VIEW Illustration C Using appropriate hardware for your type of gate attach the vertical closed position stop plate to the SECOND gate frame at the point where it will come in contact with the ground stop post.. Do not tighten it completely at this time. You must slide the closed position stop plate toward the ground stop until they touch (Illustration C). Once you have moved the stop plate to the correct position, tighten its hardware completely. NOTE: For a push-to-open installation (gate opens out from the property) attach the closed position stop plate to the outside of the gate. At this stage of the installation, the openers should be installed on the gate leaves and the open and closed position stops should be in place. SECOND Gate Opener Post Bracket Assembly MASTER Gate Opener Gate Bracket Closed Position Positive Stop Plates OPTIONAL Closed Position Ground Stop Post 18 Mounting the Control Box Step 1 Mount the control box using the screws (provided) or another secure mounting method. The control box must be mounted at least 3 feet above the ground to protect it from rain splash, snow, etc., and at least 3 feet from an AC power source to prevent electrical interference. NOTE: The batteries that came with your GTO® gate opener, MUST be placed in the top (horizontal) battery slot with the terminals on the RIGHT. The extra (vertical) battery slot is for the second battery. Use mounting holes and screws provided to mount control box to a secure surface. Step 2 Make sure the control box power switch is in the OFF position. The ON/OFF Switch is located on the bottom of the control box. Remove the control box cover and slide the battery into position with its terminals to the RIGHT (see illustration). Connect the BLACK battery wire to the NEGATIVE () battery terminal. Connect the RED battery wire to the POSITIVE (+) terminal. Pay close attention to the color of the wires. If the wires are connected incorrectly, the control board will be damaged. NEVER insert the battery with the terminals to the left. ALM GTO RCVR. LOCK 18 VAC or SOLAR AUX GTO CONTROL INPUTS MASTER CABLE SLAVE CABLE RECEIVER CONTROL OUTPUTS LOCK AUX PWR RLY POWER INPUTS GTO TRANSF 12 Volt Battery (included) GRN WHT BLU BRN ORG RED BLK GRN WHT BLU BRN ORG RED BLK COM COM CYCLE SAFETY EXIT SHADOW CLOSE EDGE OPEN EDGE GRN BLK RED S4 LEARN SLV LIMIT CHARGING PWR IN ON OFF MODE2 S2 ON OFF MODE1 ON DIP 1234 SIMULT. MAST LIMIT SLV OPEN DLY. LEARN PUSH PULL OPEN ON WARNING OFF ON SOFT START OFF S3 MAX 120 MIN OFF LEARN RMT BATT+ BATT- STATUS FUSE 25 AUTO CLOSE TIME STALL FORCE BLACK wire to Negative Terminal RED wire to Posative Terminal Battery wires for optional second battery. Space for optional second 12 Volt battery (see Accessory Catalog) Step 3 Strip approximately 3/16" of insulation from each wire of the power cable. Twist each exposed wire tightly (there are seven [7] wires inside the power cable sheath). Loosen sealing nut on strain relief hub at bottom of control box. Insert power cable into control box through strain relief. Thread approximately 6" of the power cable into the control box and re-tighten sealing nut until the power cable locks into place. Strain Relief Lock Nut Hub Sealing Nut 19 MASTER CABLE Connecting Opener Power Cables MASTER Operator Step 4 Insert the stripped power cable wires into the appropriate terminals on the MASTER CABLE terminal block. The green wire should be inserted into the GRN terminal, the white wire into WHT, the blue wire into BLU, brown wire into BRN, the orange wire into the ORG, the red wire into the RED, and the black wire into the BLK terminal. Tighten the set screws against the end of the wires. Correct Wrong Wrong Terminal Wire Block Screwed into Exposed strands wire insulation of wire GRN WHT BLU BRN ORG RED BLK Power Cable from the COM Master Operator Arm COM CYCLE SAFETY EXIT SHADOW CLOSE EDGE OPEN EDGE GRN BLK RED CONTROL INPUTS RECEIVER GTO RCVR. SECOND Operator Step 5 Review the Installation Overview illustration on page 11 before proceeding. Cut a 6" deep slot into the driveway to accommodate PVC conduit (not provided). The buried conduit will protect the 32 foot power cable from automobile tires, lawn mower blades, weed eaters, and grazing animals. Pull the second opener power cable through the conduit and secure them into the slot in the driveway. CONTROL OUTPUTS LOCK AUX PWR RLY GTO LOCK SLAVE CABLE Step 6 Strip approximately 3/16" of insulation from each wire of the second opener power cable. Twist each exposed wire tightly. Insert the second opener power cable upward through the right strain relief (if necessary, loosen the sealing nut). Thread approximately 4" of wire into the control box. Re-tighten strain relief (on the black sheath of the power cable) until the power cable locks into place. Insert the stripped wires of the power cable into the appropriate terminals on the SECOND operator terminal block. The green wire should be inserted into the GRN terminal, the white wire into WHT, the blue wire into BLUE, brown wire into BRN, and the orange wire into the ORG terminal, red wire into RED, and black wire into BLK. Tighten the set screws against the end of the wires. Power Cable from the Slave Operator Arm GRN WHT BLU BRN ORG RED BLK GRN WHT BLU BRN ORG RED BLK COM COM CYCLE AUX MASTER CABLE CON 20 Powering the System Installation of the Transformer IMPORTANT: · The transformer is designed and intended for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover or housing (available at local electrical supply stores) must be used. · All low voltage wire used with the GTO® Gate Opener must be 16 gauge dual conductor, stranded, direct burial wire (see page 22 and the accessory pages). Do not run more than 1000 feet of wire. · If your gate is more than 1000 ft. from an ac power source, you will need to use at least one 10 watt Solar Panel to charge the battery (see the accessory pages). Refer to the Solar Panels and Gate Activity chart below. OPTIONAL Solar Panels and Gate Activity The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 10 to 30 watts of solar charging power. (see Accessory Catalog). The figures shown are for winter (minimum sunlight) and do not account for the use of any accessory items. Accessories connected to your system will draw additional power from the battery. Winter Ratings 12 v dual gate (10 watts) solar charger 12 v dual gate (15 watts) solar charger 12 v dual gate (20 watts) solar charger 12 v dual gate (25 watts) solar charger 12 v dual gate (30 watts) solar charger Zone 1 4 7 10 13 16 Zone 2 8 13 18 23 28 Zone 3 13 20 27 34 41 NOTE: A maximum of 30 watts of solar charging power can be connected to the GTO® Gate Opener. Consult Solar Panel Installation Instructions for further information. ON/OFF Switch Step 1 Make sure the power switch is OFF before proceeding to the next step. Step 2 Select the electrical outlet into which you will plug the transformer. Measure the distance from this outlet to the control box following the path where the wire will be laid. After you have measured how much wire is needed, cut the wire to the appropriate length. 21 IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, PVC sheathed wire. This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft. DO NOT use telephone wire or solid core wire. Unlike stranded wire, these types of wire are not appropiate for use with your gate opener system. AVOID splicing wires together. Splicing permits corrosion and seriously degrades the wire's ability to carry an adequate current. Step 3 Lay the measured length of low voltage wire in a trench 18 VAC or SOLAR following a path from the selected electrical outlet to the GTO LOCK AUX control box. Wires coming up from the ground should GRN be run through PVC conduit to protect them from lawn WHT BLU BRN ORG RED mower blades, weed eaters, and grazing animals. Be sure BLK GRN WHT to bury the wire laid in the trench. BLU BRN ORG RED BLK COM COM CYCLE SAFETY EXIT Step 4 SHADOW CLOSE EDGE OPEN EDGE GRN BLK RED Feed the low voltage wires upward through the strain relief opening on the lower left of the control box. Pull 6" to 8" of wire into the control box and tighten the strain relief screw to secure the wires. Low Voltage Wire from Transformer ALM GTO RCVR. WARNING! DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING THIS STEP! THE TRANSFORMER MUST ONLY BE PLUGGED INTO AN OUTLET DURING STEP 7! Step 5 Strip 3/16" off the ends of the low voltage wire and twist tightly. Attach these ends to the 18VAC terminals located on the POWER IN terminal block (see illustration at right). Be certain not to let the exposed wires touch each other! Insert one transformer wire into an 18VAC terminal. Insert the other transformer wire into the remaining 18VAC terminal. The transformer wires can be connected to the 18VAC terminals regardless of polarity or color. RED BLACK Low Voltage Wire from AC Transformer or Solar Panel Tighten set screws against exposed end of wires. CONTROL INPUTS MASTER CABLE SLAVE CABLE RECEIVER CONTROL OUTPUTS LOCK AUX PWR RLY POWER INPUTS GTO TRANSF S4 LOCK GTO 18VOLT TRANSFORMER OR SOLAR LEARN SLV LIMIT CHARGING PWR IN ON OFF MODE2 S2 ON OFF MODE1 ON DIP 1234 SIMULT. MAST LIMIT SLV OPEN DLY. AUX GTO LEARN PUSH PULL OPEN ON WARNING OFF ON SOFT START OFF S3 MAX 120 MIN OFF LEARN RMT BATT+ BATT- STATUS FUSE 25 AUTO CLOSE TIME STALL FORCE MASTER CABLE SLAVE CABLE CONTROL OUTPUTS LOCK AUX PWR RLY POWER INPUT Power Cable from Slave Arm Power Cable from Master Arm PVC Pipe GRN WHT BLU BRN ORG RED BLK GRN WHT BLU BRN ORG RED BLK 22 Step 6 Strip 1/2" of insulation from the ends of the low voltage wire. Attach these stripped ends to the transformer terminals. A dab of household petroleum jelly on each terminal will help prevent corrosion. Make sure the exposed wires do not touch each other! SURGE PROTECTOR Step 7 Plug the transformer into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended.) HINT: Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board. NOTE: If transformer will be located outside be sure to enclose in a weatherproof cover (not included). Transformer 23 CONTROL BOARD SETTINGS DIP Switches DIP Switch Settings (MODES) DIP Switch #1 - Soft Start/Stop ON - Soft start enabled (factory preset). OFF - Soft start disabled. The Soft Start/Stop feature slowly starts the gate as it begins to open and slows the gate as it comes to the closed position. This saves wear and tear on the gate and gate opener system. DIP Switch #2 - Warning Buzzer ON - Buzzer warning enabled (factory preset). OFF - Buzzer warning disabled. The Warning Buzzer alerts you when the gate opener is beginning to either open or close the gate. It sounds for the first 2 seconds in each direction. It also sounds a warning when the gate obstructs two times in one cycle. Switching this to OFF disables the open and close warning not the obstruction warning. DIP Switch #3 - Push/Pull-to-Open ON - Push to open. OFF - Pull to open (factory preset). If your gate opens into the property the DIP Switch is set to the OFF position (factory setting). If your gate opens out from the property the DIP Switch must be set to the ON position. NOTE: if you have a Push-to-Open gate application you will need a Push-to-Open bracket (see Push-toOpen Instructions on page 30). DIP Switch #4 - Delay/Simultaneous operation ON - Second opens simultaneously with master. OFF - Second opens after master (factory preset). ON ON DIP 1234 OFF AUTO CLOSE TIME STALL FORCE STATUS OFF 120 MIN SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY. MODE1 OFF MODE2 OFF ON DIP 1 2 3 4 LEARN RMT MAX ON S3 ON PUSH LEARN SIMULT. MAST LIMIT ON ON S2 LEARN SLV LIMIT S4 Auto Close The 'AUTO CLOSE TIME' pot controls auto close feature. Turning the pot all the way counter-clockwise will turn auto close feature off. The minimum time is 3 seconds. The maximum (turn the pot all the way clockwise) time is 120 seconds. Auto Close Time Pot AUTO CLOSE TIME STALL FORCE STATUS OFF 120 MIN SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY. MODE1 OFF MODE2 OFF ON DIP 1 2 3 4 LEARN RMT MAX ON S3 ON PUSH LEARN SIMULT. MAST LIMIT ON S2 ON LEARN 24 Setting the Closed Position Limits for Pull to Open Applications TURN CONTROL BOX ON NOTE: The OPEN limit is when the opener is fully retracted and the gate is in the full open position. The open limit setting can only be adjusted by moving the gate bracket. To achieve the optimum closed position, you must adjust the CLOSED limit setting: Step 1 Confirm that the power switch is in the ON position, and the gates are in the OPEN POSITIONS. Step 2 Activate your openers by pressing the entry transmitter button. Your gates should now be moving from the fully open positions toward their closing position. Prepare to STOP gate that reaches the desired closed position first by pressing the entry transmitter button again. This step may be repeated until desired close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 3. Step 3 Note which gate has reached the desired closed position (typically it's the Second gate), program the closed limit setting by pressing and holding the corresponding 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' for 5 seconds. Step 4 Press the transmitter button and allow the gates to return to the fully open position. YOUR FIRST GATE'S CLOSED POSITION LIMIT IS NOW PROGRAMMED. CLOSE TIME STALL FORCE STATUS 120 MIN ART OFF G OFF PULL EN DLY. OFF OFF ON DIP 1 2 3 4 LEARN RMT MAX ON S3 ON PUSH LEARN SIMULT. MAST LIMIT ON S2 ON LEARN SLV LIMIT S4 Learn Master Limit Button Learn Slave Limit Button Step 5 Activate your openers again by pressing the entry transmitter button. Your gates should now be moving from the fully open positions toward their closing position. The gate programmed in Step 4 will stop at the spot you just programmed and the other gate will continue to close until you press the transmitter button again. The optimum CLOSED POSITION for the second gate is when it closes firmly, without excess tension, against the first gate. This step may be repeated until desired close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 6. Step 6 Repeat step 3 for the other gate that has not been set in step 3. Step 7 Press the transmitter button and allow the gates to return to the fully open position. BOTH YOUR MASTER AND SECOND GATE'S CLOSED POSITION LIMITS ARE NOW PROGRAMMED. 25 TESTING YOUR CLOSED LIMIT SETTING: Press your entry transmitter and allow your gates to close. If CLOSED positions are not correct or need to be changed, you will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-7 again. CLEARING PROGRAMMED CLOSED LIMIT SETTING: If you make a mistake and set the limit at the wrong position press your transmitter to return the gates to their fully opened positions, then press and hold the 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' button for 5 seconds. This will clear the memory for the closed limit positions. Follow Steps 1-7 again. Setting Your Personal Transmitter Code All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO® Gate Opener®. For your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code. Follow the directions below: 1. Remove the Transmitter Cover On the back of the transmitter use a small phillips head screw driver to remove the two screws on the sides of the visor clip and separate the front cover from the transmitter. With the front cover removed, the battery and the DIP switches will be exposed. To set a new code, use a small screwdriver to move the switches. 2. Set the transmitter DIP Switches LED +1 0 2 3 4 5 6 A23S 12V ALKALINE BATTERY 7 8 9 ECE There are nine (9) transmitter DIP switches; each can be placed in three different positions (+, 0, ). DO NOT set all the switches in the same position, such as all +, all 0, or all . Once the DIP switches have been set to a personal code, replace front cover. 1 2 3 4 5 6 7 8 9 + 0 ECE WARNING: No other adjustments should be made inside the transmitter. 3. "Teach" the New Code to Control Board Memory A. Press and hold transmitter button. B. Press and hold the LEARN RMT (Learn Remote) button on the control board until the buzzer sounds. C. Release transmitter button. The new code is stored in control board memory. D. Release the LEARN RMT (Learn Remote) button. CLOSE TIME STALL FORCE STATUS 120 MIN ART OFF G OFF PULL EN DLY. OFF OFF ON DIP 1 2 3 4 LEARN RMT MAX ON S3 ON PUSH LEARN SIMULT. MAST LIMIT ON S2 ON LEARN SLV LIMIT S4 Learn Remote Button 26 Obstruction Sensitivity Potentiometer IMPORTANT: For safety reasons the obstruction setting or Stall Force on the GTO® gate opener control board comes from the factory set at MIN (minimum). In many gate installations this setting will need to be adjusted to overcome the weight and size of the gates. STALL FORCE MIN MAX The Stall Force potentiometer on the control board operates like a volume control on a radio. It controls the obstruction sensitivity (or the amount of force the opener will apply to an obstruction) before it automatically stops and reverses direction for approximately two (2) seconds. AUTO CLOSE TIME STALL FORCE OFF 120 MIN SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY. MODE1 OFF MODE2 OFF ON 1 2 3 4 MAX ON ON PUS SIM ON ON Use a small flat blade screwdriver to turn the arrow in the center of the potentiometer. Adjust the sensitivity from the MINIMUM position where the gate operates without obstructing from its own weight or the wind conditions in your area. NOTE: You may need to increase the stall force in cold weather due to increased resistance from gate hinges. ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR AUTOMATIC GATE OPENER! Installing the Receiver Use the transmitter to check the range of the receiver before permanently mounting it. Consider the following when mounting the receiver: · Standard receiver cable length is 10 feet (receivers with a longer cable are available as special order items; call the GTO Sales Department). NEVER splice receiver cable! · Run the cable through PVC conduit to protect it from damage. · DO NOT run cable in conduit containing ac wiring. · DO NOT mount receiver on a metal fence or post; doing so will decrease signal range. · The receiver range can vary from 50 to 100 feet depending upon weather, topography, and external interference. · DO NOT mount upside down. · MOUNT so that you have line of sight between remote and antenna. · MOUNT 3 feet away from AC voltage. · MOUNT as high as possible for optimum range. FCC Regulation This device complies with FCC rules Part 15. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept an interference that may cause undesired operation. Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. 27 Connnecting Accessories Input Connections · All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these inputs. · All inputs are connected with respect to COMMON terminal. · The status LED will blink once when any input is activated. 1 COM: Circuit common (reference for all logic input) BLK · Two (2) terminals to provide extra common connection point. 2 CYCLE/CLOSE: (Typically for use with 1 push button or hard-wired keypad) · Each activation at this input will cycle the operation as follows: OPENSTOPCLOSESTOPOPEN 2 COM COM CYCLE CONTROL INPUTS RECEIVER ALM GTO RCVR. 3 SAFETY: (Typically for use with photo 3 beam device, loop detector or other non-contact sensors) 4 · Activation of this input while the gate is closing will cause the gate to stop 5 and return to the opened position. · Activation of this input while the gate 6 is opening has no effect (gate will continue to open). 7 · Activation of this input while gate is idle will prevent gate from closing. 4 EXIT/OPEN: (Typically for use with exit loop or wand) · Activation of this input will open the gate if it's not already at the open position · Activation of this input while at open limit will restart the auto close time (if enabled). SAFETY EXIT SHADOW CLOSE EDGE OPEN EDGE GRN BLK RED 5 SHADOW LOOP: (Typically for use with loop detector) · This input is only monitored when the gate is at the fully open position. At any other position, activation of this input has no effect on gate operation. · Activation of this input while gate at the fully open position will prevent gate from closing. 6 CLOSE EDGE: (Typically for use with safety edge device) · Activation of this input while the gate is closing will cause the gate to stop and reverse direction for approximately 2 seconds. · Activation of this input while the gate is opening has no effect (gate will continue to open). · Activation of this input while gate is idle will prevent gate from closing. 7 OPEN EDGE: (Typically for use with safety edge device) · Activation of this input while the gate is opening will cause the gate to stop and reverse direction for approximately 2 seconds. · Activation of this input while the gate is closing has no effect (gate will continue to close). · Activation of this input while gate is idle will prevent gate from opening. 28 Wiring Accessories CONTROL OUTPUTS POWER 2ND OIPNEPRUATTOR LOCK AUX PWR RLYMASTER OP2ENRDATOOPRERATOR CONTROMLAISNTPEURTOSPERATORRECEIVER CONTROL INPUTS 2 3 4 56 7 GTO 18 VOLT TRANSF. OR SOLAR PANEL 1 2 3 4 5 6 71 2 3456 7 ALM GTO RCVR. WHT BLU BRN ORG RED BLK GRN WHT BGLRUN BRN WHT ORG BLU RED BRN BLK ORG RED COM BLK COM CYCLE SAFGERTNY EWXIHTT SHABDLOUW CLBORSNE EDGE OOPREGN EDGE RED GRN BBLLKK RED COM COM CYCLE Automatic Gate Lock (FM144 & FM142) 6 According to 7 Application 1 Edge Sensor 1 2 Push Button Control (RB101) 3 1 Photo Beams (R4222) 123 ABC DEF 456 GHI JKL MNO 789 PRS TUV WXY 0 1 2 Digital Keypad (F310) 4 1 Vehicle Sensor (FM139) Refer to Vehicle Sensor manual for additional connections. NOTE: There may be additional connection options for applications that are not illustrated here. Refer to accessory manuals for details. Connecting Other Auxiliary Devices (Sirens, Lights, etc.) AUX RLY · These 2 terminals are normally open "dry-contact" (no voltage) relay ouput. · Relay is closed when the gate is in motion; Relay is open when the gate is not in motion. · These 2 terminals maximum rating is 24Vdc, 1 Amp. 29 Push to Open Installation Determining The Mounting Position of The Post Bracket Assembly Post Bracket Assembly Swinging gates shall not open into public access areas! A "Push-to-Open" gate opens out from the property. A Push-to-Open Bracket is required for this type of installation (see Accessory Catalog). If you have a pull-to-open gate (gate opens into the property), return to page 13; step 3. In a PUSH-TO-OPEN installation the openers are installed while the gates are in the closed position. Step 1 With the gates closed, adjust the post bracket assembly and the gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate. 3/8" x 2" Bolt Post Bracket Push-To-Open Bracket (optional accessory) Post Bracket 3/8" Washer 3/8" Lock Washer 3/8" Nut IMPORTANT: While determining the mounting point for the post pivot bracket assembly be sure that the position allows for maximum clearance between the gate and the opener in both the open and closed positions, as shown in the diagrams below. This clearance will give the opener the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. Step 2 After verifying that you have the best position for the post pivot bracket, insert the 5/16" x 1 3/4" bolt through the aligned holes of the post bracket Gate in the Open Positionand post pivot bracket washer and nut. and fasten it with the 5/16" Pinch Area (gray) IMPORTANT: If you loosened the clamp on the post bracket to achieve the optimum position, tighten it in its new position and recheck the gate bracket with the gate in the open position (move the gate bracket and re-clamp it if necessary). 2" minimum Gate in the Closed Position Pinch Area (gray) 30 *The Troubleshooting Wizard has detailed information on Push-To-Open installations. Step 3 With the gate in the fully closed position and the opener retracted, swing the opener to the gate. Mark reference points for bolt holes on gate cross member through middle of gate bracket slots. The opener must be level. (Some vertical adjustment is possible by sliding the post bracket assembly up and down.) Drill 3/8" holes into the gate cross member as marked. Fasten gate bracket to cross member using (2) 3/8" x 3" bolts, washers, lock washers, and nuts. Attach the opener to the post bracket assembly and gate bracket using clevis pins, bushings, and hairpins clips. Fence Post Gate Post and Gate Cross Member (In Closed Position) LEVEL Operator LEVEL POST PIVOT BRACKET level with the horizontal surface of the GATE BRACKET Step 4 Make sure the control box power switch is OFF. Use a small screwdriver to move the Number 3 DIP switch from the factory setting (OFF / Pull-To-Open) to ON for Push-To-Open. Turn power switch ON. The control board is now configured to push the gate open. Step 5 Install the second gate opener on the other gate in the same manner. Then refer to the CONTROL BOARD SETTINGS on page 25 for gate sequencing and other programming steps before proceeding. LEVEL MAX ON ON PUSH SIMULT. ON ON AUTO CLOSE TIME STALL FORCE OFF OFF SLV OPEN DLY. WARNING OFF SOFT START OFF ON ON DIP 1234 OFF 120 MIN OONN DIP 1 2 3 4 PULL MODE1 OPEN OFF DIP#3 ON Push-to-open operation. OFF Pull-to-open operation (factory setting). Setting the Open Position Limit Step 1 Confirm that the power switch is in the ON position, and the gates are in the CLOSED POSITIONS. Step 2 Activate your openers by pressing the entry transmitter button. Your gates should now be moving from the closed positions toward their open position. Prepare to STOP gates by pressing the entry transmitter button again when the first gate reaches the desired open position. This step may be repeated until desired open position is achieved. Once the desired OPEN position has been achieved, proceed to step 3. 31 Step 3 Note which gate has reached the desired closed position (typically it's the SECOND gate), program the closed limit setting by pressing and holding the corresponding 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' button for 5 seconds. Step 4 Press the transmitter button and allow the gates to return to the closed position. YOUR FIRST GATE'S OPEN POSITION LIMIT IS NOW PROGRAMMED. Step 5 Activate your openers again by pressing the entry transmitter button. Your gates should now be moving from the closed positions toward their open positions. The first gate will stop at the spot you just programmed and the second gate will continue to open until you press the transmitter button again. Press the transmitter button when the second gate reaches the desired open position. This step may be repeated until desired open position is achieved. Once the desired OPEN position has been achieved, proceed to step 6. CLOSE TIME STALL FORCE STATUS 120 MIN ART OFF G OFF PULL EN DLY. OFF OFF ON DIP 1 2 3 4 LEARN RMT MAX ON S3 ON PUSH LEARN SIMULT. MAST LIMIT ON S2 ON LEARN SLV LIMIT Step 6 S4 Repeat step 3 for the other gate that has not been set in step 3. Step 7 Press the transmitter button and allow the gates to return to the closed position. BOTH YOUR MASTER AND SECOND GATE'S OPEN POSITION LIMITS ARE NOW PROGRAMMED. Learn Master Limit Button Learn Slave Limit Button TESTING YOUR OPEN LIMIT SETTING: Press your entry transmitter and allow your gates to open. If OPEN positions are not correct or need to be changed, you will need to CLEAR your OPEN LIMIT settings and follow steps one (1) to seven (7) again. CLEARING THE PROGRAMMED OPEN LIMIT SETTING: If you make a mistake and set the limit at the wrong position press your transmitter to return the gates to their closed positions, then press and hold the 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' button for 5 seconds. This will clear the memory for the open limit positions. Follow steps one (1) to seven (7) again. 32 Troubleshooting Guide If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department. VOLTAGE READINGS 18 Vac Transformer...................................................................................... 18.0 to 22.0 Vac, 2200 mA 5 W Solar panel (single)............................................................................. 18.0 to 22.0 Vdc, 300 mA * measure voltage at panel and control box. Two 12 V, 7 amp hour Batteries.............................................................. 12.5 to 13.5 Vdc 7.0 Ah *measure voltage at battery terminals with battery disconnected from circuit board Charging circuit ........................................................................................... 13.3 to 14.8 Vdc *measure voltage at battery terminals with battery connected to circuit board and GREEN "POWER IN" LED is ON. Audible Feedback Indication Possible Diagnosis Check 1 short beep upon activation Blown Fuse Low or Bad Battery Loose Battery Connection 1 short beep upon power up Circuit Board Powered Up & Ready Continuous Uninterrupted Circuit Board Senses an Alarm Obstruction 1 beep with 10 seconds off Low Battery Condition 1 beep then 2 beeps Master Motor Terminals Shorted 1 beep then 3 beeps Second Motor Terminals Shorted 1 beep with 2 seconds off Master Arm Limit Switch Error · Fuse · Battery Under Load · Battery Harness Connections · Normal Operation · Path of Gate · Gate for Level and Plumb · Stall Force Adjustment · Disconnect Safety Devices · Rev Counter · Fuses · Battery Harness Connections · Battery Under Load · Connections to Master Inputs · Master Arm Power Cable · Motor · Circuit Board · Connections to Second Inputs · Second Arm Power Cable · Motor · Circuit Board · Connections to Master Inputs · Master Arm Power Cable 2 beeps with 2 seconds off Second Arm Limit Switch Error · Connections to Second Inputs · Second Arm Power Cable 3 beeps with 2 seconds off Master Arm Rev Counter Error 4 beeps with 2 seconds off Second Arm Rev Counter Error · Connections to Master Inputs · Master Arm Power Cable · Rev Counter · Connections to Second Inputs · Second Arm Power Cable · Rev Counter 33 Visual Feedback Indication Possible Diagnosis Check Status (clear) 1 blink Cycle Terminal Shorted Status (clear) 2 blinks Safety Terminal Shorted Disconnect the push button, keypad, intercom keypad, or any other accessory wired to this terminal. Try the remote. If the remote works, then the problem is the accessory. Disconnect the loop detector, photo beam, or any other accessory wired to this terminal. Try the remote. If the remote works, the problem is the accessory. Status (clear) 3 blinks Exit Terminal Shorted Disconnect exit wand, loop detector, photo beam, Knox box, or any other accessory wired to this terminal. Try remote. If the remote works, the problem is the accessory. Status (clear) 4 blinks Shadow Terminal Shorted Disconnect the loop detector, photo beam, or any other accessory wired to this terminal. Try remote. If the remote works, the problem is the accessory. Status (clear) 5 blinks Close Edge Terminal Disconnect the edge sensor, photo beam, or any other accessory wired to this Shorted terminal. Try the remote. If the remote works, the problem is the accessory. Status (clear) 6 blinks Open Edge Terminal Disconnect edge sensor, photo beam, or any other accessory wired to this Shorted terminal. Try the remote. If the remote works, the problem is the accessory. RF (yellow) Flickers Receiving 318 MHz Normal operation when remote or wireless keypad is used. RF RF (yellow) OFF No 318 MHz RF Received · Battery in Remote · Program Remote · Antenna Receiver Connections · Antenna Receiver Power (green) ON AC or Solar Power Normal Operation Present Power (green) OFF No AC or Solar Power Transformer: · Breaker or GFI · Power at AC outlet. · Output of Transformer. · Voltage on wire at 18 VAC Input Solar: · Weather · Solar Panel Placement · Output of Solar Panel · Voltage on wire at Solar Input Charge (red) ON Charge (red) Fast Blinking 2/second Charge (red) Slow Blinking 2/second Charge (red) OFF Fast Charging Mode Battery Voltage should be ~ slowly increasing Soak Charging Mode Battery Voltage should be ~14.1 VDC Float Charge Battery Voltage should be ~13.8 VDC Battery Not Being Charged AC power Transformer Solar Panel Charging Circuit 34 Battery/Power Troubleshooting RED LED GREEN LED CHARGING POWER IN FUSE 15 BATT+ BATT- CHARGING POWER IN AUTO CLOSE TIME STALL FORCE STATUS OFF 120 MIN SOFT START OFF WARNING OFF OPEN PULL 2ND OPEN DLY. MODE1 OFF MODE2 OFF ON 1 2 3 4 LEARN RMT MAX ON S3 ON PUSH LEARN SIMULT. MAST LIMIT ON S2 ON LEARN 2ND LIMIT DIAG S4 PORT POWER IN LED ON ON ON OFF OFF OFF POWER INPUT CONTROL OUTPUTS LOCK AUX PWR RLY 2ND OPERATOR 12 3 4 56 7 GTO 18 VOLT TRANSF. OR SOLAR PANEL MASTER OPERATOR CONTROL INPUTS RECEIVER ALM GTO RCVR. GRN WHT BLU BRN ORG RED BLK GRN WHT BLU BRN ORG RED BLK COM COM CYCLE SAFETY EXIT SHADOW CLOSE EDGE OPEN EDGE GRN BLK RED CHARGING LED Steady ON Blinking OFF OFF Blinking Steady ON Battery Charging Battery Fully Charged Bad Charger No AC/Solar Power Low Battery Bad Charger Repair Service If your Gate Operator is not operating properly, please follow the steps below: 1. First use the procedures found in the Troubleshooting Guide (see page 25). 2. Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com. 3. If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 5754144. Refer to the serial number (located on the right side of the control box) and date of purchase when calling for assistance. 4. If repair or replacement of your gate operator is necessary, the Service Department will assign a Return Goods Authorization (RGA) number to you. 5. Securely pack the component(s) authorized for return to the factory. Include a copy of your sales receipt for the purchase of the product(s). Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT. Ship the package(s) freight prepaid to: GTO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303. NOTE: Products returned to GTO without a Return Goods Authorization (RGA) number in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items returned to GTO freight collect WILL NOT be accepted. GTO Technical Service and Installation Assistance 8:00am7:00pm · MondayFriday (EST) Toll Free Support: 800-543-1236 · Local Support: 850-575-4144 · Fax: 850-575-8950 24/7 Troubleshooting Wizard: http://support.gtoinc.com 35 Column Installation Information IF THIS OPENER WILL BE USED WITH GATES THAT ARE MOUNTED ON MASONRY, BRICK, OR ROCK (etc.) COLUMNS: READ THE FOLLOWING CAREFULLY BEFORE PROCEEDING A. The simplest solution is to install the opener in a push-to-open configuration (requires Push-To-Open Bracket, see Accessory Catalog). The minimum clearance is easier to achieve and clearance is no longer a problem, since the opener will be pushing the gate away from the column instead of pulling it toward the column. It is recommended that you place a steel plate between the opener mounting brackets and masonry surface for additional strength. B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the back corner of the columns. C. The most difficult solution is to cut a notch in the column to accommodate the opener and power cable. This job is NOT for the inexperienced! Hinge Column B Pivot Bracket A Gate Column Mount Example (A + B can not exceed 19 inches) Example: If A is 6" then B cannot exceed 13" *The Troubleshooting Wizard has detailed information on column mounting. 36 Accessories Please visit www.gtoaccess.com for photos and detailed descriptions of GTO Accessories. Or call 1-800-543-GATE (4283). POWERING ACCESSORIES Low Voltage Wire [RB509] The 16 gauge, stranded, dual conductor low voltage Wire is for connecting the AC powered transformer, solar panel or wired accessories to the system's control board. This specially designed wire is UV treated, PVC coated, and ready for direct burial. Solar Panel Kits [FM122/FM123] If your gate operator is more than 1000 ft. away from an AC power outlet, you can choose to maintain the battery charge with the GTO Solar Panel Kit. · 10 Watt Solar Panel Charging Kit [FM123] · 5 Watt Solar Panel Charging Kit [FM122] Additional/Replacement Battery [RB500] For additional battery power or replacement. "FROM VEHICLE" ENTRY AND EXIT ACCESSORIES Transmitters [RB741/RB742/RB743] Purchase an additional transmitter for each vehicle in your family. The Two-Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the Universal Receiver. Or it can be programmed to open two gate operator systems. · Single Button Transmitter [RB741] · Dual Button Transmitter [RB742] · Three Button Transmitter [RB743] Universal Receiver [RB709U-NB] The Universal Antenna Receiver gives you the ability to use one remote to activate your gate operator and your garage door opener. Connects to any brand garage door opener. Up to 100 ft. range. Digital Keypad [F310] Allow friends access to your property using an identification code that you provide. 123 ABC DEF Program up to 25 entry codes for added security. Powered by three "AA" batteries (not 456 GHI JKL MNO 789 PRS TUV WXY included). 0 37 POWER KeypBaadtt Low DV 9V GrPaenrtmission ACCESS 1-80C0-O5N4T3R-O4L28S3YSTEMS Answer Residential Wireless Entry Intercom [FM136] Designed for added security to your automated gate with the ability to "speak to" and "screen" visitors safely from inside your home. Ideal for securing gate entrances while providing controlled access. Gooseneck Pedestal [F100/F110] Designed to mount digital keypads, wireless intercom systems, and other access control devices for your gate automation system. "HANDS FREE" Entry & Exit Accessories Driveway Vehicle Sensor [FM139] Automatically activates gate operator "Hands-Free" when a vehicle exits the property. Electromagnetic sensor detects vehicles in motion. · 50 ft. [FM139] · 100 ft. [FM140] · 150 ft. [FM141] Wireless Vehicle Sensor [R4500] Automatically activates gate operator "Hands-Free" when a vehicle exits the property. 100 ft. range between transmitter and receiver. Easy installation. ELECTRONGAICUASTTECEOURMLITOAY LCTOICKCK ® LOCKING & SECURITY Accessories Automatic Gate Lock [FM144/FM142] The #1 Accessory For Swing Gate Operators! Designed for added security in conjunction with GTO Automatic Gate Operators. The gate lock unlocks and locks automatically when the gate opens and closes. The perfect solution for high wind conditions. 0 1 23 ABC DEF 456 GHI JKL MNO 7 89 PRS TUV WXY ® SECURITY GATE LOCK , Inc. Bulldog Pedestrian Gate Lock [FM145] Designed to mount on horizontal swing "walk through" wood, chain link, and metal pedestrian gates opening in or out. Ideal for securing pools, condominiums, schools and any pedestrian gate. Wireless Driveway Alarm [R4450]. This device alerts you of vehicles entering your driveway (with or without an automated gate). The indoor base station signals you with a door chime when a vehicle passes the driveway sensor. 38 ADDITIONAL Accessories Photo Beams [R4222] Primary "through beam" photo beam device. Provides "non-contact" entrapment protection. Pin Lock [FM345] Use as a substitute for the clevis pin at the front mount of the gate opeator to prevent theft of the operator. · Pin Lock 10-pack: ten Pin Locks keyed alike [FM345KA]. Push Button Control [RB101] Wire this unlit push button directly to your gate operator for simple open/close/stop operation from up to 1000 ft. away. Use 16 gauge low-voltage wire. Replacement Transformer [RB570] Standard 18 volt, 2200 mA AC transformer included with the gate operator to maintain battery charge. HARDWARE Accessories Push To Open Brackets [347IH] Required when the gate operator must push a gate open (arm extends to open), such as away from a sloping driveway or where space prevents gate from opening into the property (pull to open). Order two brackets for a dual swing gate installation. Column Mount Lock Receiver [433IH] For use with the Automatic Gate Lock or Bulldog Pedestrian Gate Lock when mounting on brick columns or applications with limited space. If you have a question about any special order item, just call 1-800-543-GATE! The contents of all material available on this installation manual are copyrighted by GTO Access Systems, LLC ("GTO"), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by permission only. Copyright infringement is a violation of federal law. Mighty Mule¨, E-Z Gate¨, GTO¨, are registered trademarks of GTO Access Systems, LLC America's DIY Automatic Gate Openers is a trademark of GTO and are the exclusive property of GTO Access Systems, LLC. All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO. 39 3121 Hartsfield Road · Tallahassee, Florida, USA 32303 800-543-4283 · Fax (850) 575-8912 Web site www.gtoaccess.com 24/7 Troubleshooting Wizard: http://support.gtoinc.comAdobe PDF Library 15.0 Adobe InDesign CC 2015 (Macintosh)