BLU Products, Inc. BLUC5LMX177 Smart Phone YHLBLUC5LMX177 YHLBLUC5LMX177 bluc5lmx177
REPORT No.SZ23120301W03 TEST REPORT APPLICANT : BLU Products, Inc. PRODUCT NAME : Smart Phone MODEL NAME : C5L MAX BRAND NAME : BLU FCC ID STANDARD(S) RECEIPT DATE : YHLBLUC5LMX177 : 47 CFR Part 2 47 CFR Part 90, Subpart S : 2023-12-26 TEST DATE : 2023-12-29 to 2024-01-28 ISSUE DATE : 2024-03-06 Edited by: Peng Mi (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 43 REPORT No.SZ23120301W03 DIRECTORY 1. Technical Information ··················································································· 3 1.1. Applicant and Manufacturer Information ······················································· 3 1.2. Equipment Under Test (EUT) Description ······················································ 3 1.3. Maximum E.R.P./E.I.R.P. and Emission Designator ········································· 4 1.4. Test Standards and Results ········································································ 5 1.5. Environmental Conditions ·········································································· 6 2. 47 CFR Part 2, Part 90S Requirements ···························································· 7 2.1. Transmitter Conducted Output Power and E.R.P./E.I.R.P. ································ 7 2.2. Occupied Bandwidth ················································································· 16 2.3. Frequency Stability ···················································································25 2.4. Conducted Spurious Emissions ·································································27 2.5. Band Edge ······························································································· 30 2.6. Radiated Spurious Emissions ····································································34 Annex A Test Uncertainty ················································································ 40 Annex B Testing Laboratory Information ···························································41 Version 1.0 Change History Date 2024-03-06 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 43 1. Technical Information REPORT No.SZ23120301W03 Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Applicant Address: Manufacturer: Manufacturer Address: BLU Products, Inc. 8600 NW 36th Street, Suite #300 Miami, FL 33166, USA BLU Products, Inc. 8600 NW 36th Street, Suite #300 Miami, FL 33166, USA 1.2. Equipment Under Test (EUT) Description Product Name: Sample No.: Hardware Version: Software Version: Modulation Type: Operation Band: Frequency Range: Channel Bandwidth Antenna Type: Antenna Gain: Accessory Information: Smart Phone 6# YK507-MB-V1.0 BLU_C0176_V13.0.G.03.08_GENERIC_6-12-2023_1930 QPSK, 16QAM, 64QAM Band 26 LTE Band 26 Tx: 814MHz824MHz Rx: 859MHz869MHz LTE Band 26 1.4MHz, 3MHz, 5MHz, 10MHz PIFA Antenna LTE Band 26 -1.52dBi Battery Brand Name: BLU Model No.: C775444200L Serial No.: N/A Capacity: 2000mAh Rated Voltage: 3.8V Charge Limit: 4.35V Manufacturer: Shenzhen Aerospace Electronic Co.,Ltd MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 43 REPORT No.SZ23120301W03 AC Adapter Brand Name: BLU Model No.: US-TY-1000 Accessory Information: Serial No.: Rated Output: N/A 5V 1000A Rated Input: 100-240V 50/60Hz, 0.15A Manufacturer: SHENZHEN TIANYIN ELECTRONICS CO., LTD. Note 1: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. 1.3. Maximum E.R.P./E.I.R.P. and Emission Designator LTE Band 26 BW(MHz) 10 5 3 1.4 Maximum E.R.P./E.I.R.P. (W) QPSK 16QAM 64QAM 0.078 0.078 0.075 0.078 0.086 0.079 0.078 0.077 0.078 0.078 0.079 0.079 Emission Designator (99%OBW) QPSK 16QAM 64QAM 9M01G7D 8M97W7D 8M99W7D 4M50G7D 4M50W7D 4M51W7D 2M69G7D 2M70W7D 2M70W7D 1M09G7D 1M10W7D 1M10W7D MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 43 1.4. Test Standards and Results REPORT No.SZ23120301W03 The objective of the report is to perform testing according to Part 2 and Part 90 for the EUT FCC ID Certification: No Identity Document Title 1 47 CFR Part 2 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations 2 47 CFR Part 90 Miscellaneous Wireless Communications Services Test detailed items/section required by FCC rules and results are as below: Section Description Test Date Test Engineer Result Method Determination /Remark 2.1046, 90.635(b) Transmitter Conducted Output Power and ERP/EIRP Jan. 24, 2024 Chen Hao PASS No deviation 90.209 Occupied Bandwidth Jan. 10, 2024 Gan Jing PASS No deviation 2.1055, 90.213 Frequency Stability Jan. 24, 2024 Gan Jing PASS No deviation 2.1051, 90.691 Conducted Spurious Emissions Jan. 10, 2024 Gan Jing PASS No deviation 2.1051, 90.691 Band Edge Jan. 09, 2024 Gan Jing PASS No deviation 2.1053, 90.691 Radiated Spurious Emissions Nov. 29, 2023 to Jan. 28, 2024 Gao Jianrou PASS No deviation Note 1: The tests were performed according to the method of measurements prescribed in KDB971168 D01 v03 and ANSI/TIA-603-E-2016. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 43 1.5. Environmental Conditions REPORT No.SZ23120301W03 During the measurement, the environmental conditions were within the listed ranges: Temperature (°C): 15-35 Relative Humidity (%): 30-60 Atmospheric Pressure (kPa): 86-106 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 43 REPORT No.SZ23120301W03 2. 47 CFR Part 2, Part 90S Requirements 2.1. Transmitter Conducted Output Power and E.R.P./E.I.R.P. 2.1.1. Requirement According to FCC section 2.1046(a), for transmitters other than single sideband, independent sideband and controlled carrier radiotelephone, power output shall be measured at the RF output terminals when the transmitter is adjusted in accordance with the tune-up procedure to give the values of current and voltage on the circuit elements specified in FCC section 2.1033(c)(8). According to FCC section 90.635(b) for LTE Band 26, the maximum output power of the transmitter for mobile stations is 100 watts. 2.1.2. Test Description The EUT is coupled to the Spectrum Analyzer (SA) and the System Simulator (SS) with Attenuators through the Power Splitter; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. The EUT is commanded by the SS to operate at the maximum output power. A call is established between the EUT and the SS. 2.1.3. Test procedure KDB 971168 D01v03 Section 5.2 and ANSI/TIA-603-E-2016. EIRP (dBm) = Conducted Output Power (dBm) + Antenna Gain (dBi) ERP (dBm) = EIPR (dBm) - 2.15 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 43 REPORT No.SZ23120301W03 2.1.4. Result Conducted Output Power BW [MHz] Modulation RB Size Channel Frequency (MHz) 10 QPSK 1 10 QPSK 1 10 QPSK 1 10 QPSK 25 10 QPSK 25 10 QPSK 25 10 QPSK 50 10 16QAM 1 10 16QAM 1 10 16QAM 1 10 16QAM 25 10 16QAM 25 10 16QAM 25 10 16QAM 50 10 64QAM 1 10 64QAM 1 10 64QAM 1 10 64QAM 25 10 64QAM 25 10 64QAM 25 10 64QAM 50 LTE Band 26 RB Offset Average Power Low Ch. / Freq. / / 0 / 25 / 49 / 0 / 12 / 25 / 0 / 0 / 25 / 49 / 0 / 12 / 25 / 0 / 0 / 25 / 49 / 0 / 12 / 25 / 0 / Average Power Middle Ch. / Freq. 26740 819.0 22.35 22.59 22.45 22.59 22.52 22.45 22.48 22.31 22.32 22.19 22.60 22.22 22.13 22.31 21.98 22.03 21.89 22.40 22.42 22.28 22.40 Average Power High Ch. / Freq. / / / / / / / / / / / / / / / / / / / / / / / MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 43 REPORT No.SZ23120301W03 BW [MHz] Modulation RB Size Channel Frequency (MHz) 5 QPSK 1 5 QPSK 1 5 QPSK 1 5 QPSK 12 5 QPSK 12 5 QPSK 12 5 QPSK 25 5 16QAM 1 5 16QAM 1 5 16QAM 1 5 16QAM 12 5 16QAM 12 5 16QAM 12 5 16QAM 25 5 64QAM 1 5 64QAM 1 5 64QAM 1 5 64QAM 12 5 64QAM 12 5 64QAM 12 5 64QAM 25 LTE Band 26 RB Offset Average Power Low Ch. / Freq. 26715 816.5 0 22.29 12 22.36 24 22.27 0 22.44 7 22.55 13 22.47 0 22.46 0 22.19 12 22.57 24 22.24 0 22.46 7 22.60 13 22.37 0 22.36 0 22.03 12 22.59 24 22.19 0 22.40 7 22.64 13 22.47 0 22.54 Average Power Middle Ch. / Freq. 26740 819.0 22.37 22.18 22.12 22.50 22.58 22.45 22.16 22.36 22.52 22.22 22.34 22.35 22.18 22.26 22.07 22.35 22.08 22.42 22.25 22.25 22.37 Average Power High Ch. / Freq. 26765 821.5 22.36 22.52 22.28 22.13 22.47 22.39 22.23 22.76 22.99 22.55 22.31 22.54 22.50 22.53 22.19 22.36 22.33 22.48 22.57 22.27 22.52 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 43 REPORT No.SZ23120301W03 BW [MHz] Modulation RB Size Channel Frequency (MHz) 3 QPSK 1 3 QPSK 1 3 QPSK 1 3 QPSK 8 3 QPSK 8 3 QPSK 8 3 QPSK 15 3 16QAM 1 3 16QAM 1 3 16QAM 1 3 16QAM 8 3 16QAM 8 3 16QAM 8 3 16QAM 15 3 64QAM 1 3 64QAM 1 3 64QAM 1 3 64QAM 8 3 64QAM 8 3 64QAM 8 3 64QAM 15 LTE Band 26 RB Offset Average Power Low Ch. / Freq. 26705 815.5 0 22.31 8 22.47 14 22.30 0 22.41 4 22.26 7 22.28 0 22.39 0 22.45 8 22.54 14 22.47 0 22.51 4 22.55 7 22.51 0 22.52 0 22.17 8 22.36 14 22.23 0 22.28 4 22.11 7 22.39 0 22.51 Average Power Middle Ch. / Freq. 26740 819.0 22.52 22.53 22.48 22.38 22.57 22.52 22.38 22.33 22.21 22.38 22.28 22.24 22.29 22.26 22.17 21.89 22.12 22.42 22.57 22.32 22.53 Average Power High Ch. / Freq. 26775 822.5 22.46 22.16 22.19 22.46 22.24 21.96 22.45 22.53 22.49 22.39 22.40 22.25 22.27 22.46 21.90 21.95 22.21 22.18 22.40 22.15 22.28 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 43 REPORT No.SZ23120301W03 BW [MHz] Modulation RB Size Channel Frequency (MHz) 1.4 QPSK 1 1.4 QPSK 1 1.4 QPSK 1 1.4 QPSK 3 1.4 QPSK 3 1.4 QPSK 3 1.4 QPSK 6 1.4 16QAM 1 1.4 16QAM 1 1.4 16QAM 1 1.4 16QAM 3 1.4 16QAM 3 1.4 16QAM 3 1.4 16QAM 6 1.4 64QAM 1 1.4 64QAM 1 1.4 64QAM 1 1.4 64QAM 3 1.4 64QAM 3 1.4 64QAM 3 1.4 64QAM 6 LTE Band 26 RB Offset Average Power Low Ch. / Freq. 26697 814.7 0 22.36 3 22.46 5 22.39 0 22.46 1 22.52 3 22.48 0 22.50 0 22.28 3 22.39 5 22.35 0 22.16 1 22.02 3 22.30 0 22.08 0 22.12 3 22.26 5 22.16 0 22.29 1 22.17 3 22.17 0 22.29 Average Power Middle Ch. / Freq. 26740 819.0 22.48 22.58 22.38 22.14 22.43 22.51 22.47 22.09 22.56 22.20 22.53 22.60 22.58 22.63 22.28 22.38 22.23 22.62 22.64 22.64 22.57 Average Power High Ch. / Freq. 26783 823.3 22.37 22.45 22.37 22.50 22.60 22.43 22.31 22.34 22.20 22.36 22.27 22.36 22.39 22.25 22.23 22.30 22.06 22.39 22.35 22.26 22.35 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 43 REPORT No.SZ23120301W03 Effective Radiated Power and Effective Isotropic Radiated Power LTE Band 26 Measured E.R.P. BW [MHz] Modulation RB Size RB Offset Low Ch. / Freq. Middle Ch. / Freq. Channel / 26740 Frequency (MHz) / 819 / dBm W 10 QPSK 1 0 / 18.68 0.074 10 QPSK 1 25 / 18.92 0.078 10 QPSK 1 49 / 18.78 0.076 10 QPSK 25 0 / 18.92 0.078 10 QPSK 25 12 / 18.85 0.077 10 QPSK 25 25 / 18.78 0.076 10 QPSK 50 0 / 18.81 0.076 10 16QAM 1 0 / 18.64 0.073 10 16QAM 1 25 / 18.65 0.073 10 16QAM 1 49 / 18.52 0.071 10 16QAM 25 0 / 18.93 0.078 10 16QAM 25 12 / 18.55 0.072 10 16QAM 25 25 / 18.46 0.070 10 16QAM 50 0 / 18.64 0.073 10 64QAM 1 0 / 18.31 0.068 10 64QAM 1 25 / 18.36 0.069 10 64QAM 1 49 / 18.22 0.066 10 64QAM 25 0 / 18.73 0.075 10 64QAM 25 12 / 18.75 0.075 10 64QAM 25 25 / 18.61 0.073 10 64QAM 50 0 / 18.73 0.075 High Ch. / Freq. / / / / / / / / / / / / / / / / / / / / / / / / MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 43 REPORT No.SZ23120301W03 LTE Band 26 BW [MHz] Modulation RB Size Channel Frequency (MHz) 5 QPSK 1 5 QPSK 1 5 QPSK 1 5 QPSK 12 5 QPSK 12 5 QPSK 12 5 QPSK 25 5 16QAM 1 5 16QAM 1 5 16QAM 1 5 16QAM 12 5 16QAM 12 5 16QAM 12 5 16QAM 25 5 64QAM 1 5 64QAM 1 5 64QAM 1 5 64QAM 12 5 64QAM 12 5 64QAM 12 5 64QAM 25 RB Offset 0 12 24 0 7 13 0 0 12 24 0 7 13 0 0 12 24 0 7 13 0 Low Ch. / Freq. 26715 816.5 dBm W 18.62 0.073 18.69 0.074 18.60 0.072 18.77 0.075 18.88 0.077 18.80 0.076 18.79 0.076 18.52 0.071 18.90 0.078 18.57 0.072 18.79 0.076 18.93 0.078 18.70 0.074 18.69 0.074 18.36 0.069 18.92 0.078 18.52 0.071 18.73 0.075 18.97 0.079 18.80 0.076 18.87 0.077 Measured E.R.P. Middle Ch. / Freq. 26740 819.0 dBm W 18.70 0.074 18.51 0.071 18.45 0.070 18.83 0.076 18.91 0.078 18.78 0.076 18.49 0.071 18.69 0.074 18.85 0.077 18.55 0.072 18.67 0.074 18.68 0.074 18.51 0.071 18.59 0.072 18.40 0.069 18.68 0.074 18.41 0.069 18.75 0.075 18.58 0.072 18.58 0.072 18.70 0.074 High Ch. / Freq. 26765 821.5 dBm W 18.69 0.074 18.85 0.077 18.61 0.073 18.46 0.070 18.80 0.076 18.72 0.074 18.56 0.072 19.09 0.081 19.32 0.086 18.88 0.077 18.64 0.073 18.87 0.077 18.83 0.076 18.86 0.077 18.52 0.071 18.69 0.074 18.66 0.073 18.81 0.076 18.90 0.078 18.60 0.072 18.85 0.077 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 43 REPORT No.SZ23120301W03 LTE Band 26 BW [MHz] Modulation RB Size Channel Frequency (MHz) 3 QPSK 1 3 QPSK 1 3 QPSK 1 3 QPSK 8 3 QPSK 8 3 QPSK 8 3 QPSK 15 3 16QAM 1 3 16QAM 1 3 16QAM 1 3 16QAM 8 3 16QAM 8 3 16QAM 8 3 16QAM 15 3 64QAM 1 3 64QAM 1 3 64QAM 1 3 64QAM 8 3 64QAM 8 3 64QAM 8 3 64QAM 15 RB Offset 0 8 14 0 4 7 0 0 8 14 0 4 7 0 0 8 14 0 4 7 0 Low Ch. / Freq. 26705 815.5 dBm W 18.64 0.073 18.80 0.076 18.63 0.073 18.74 0.075 18.59 0.072 18.61 0.073 18.72 0.074 18.78 0.076 18.87 0.077 18.80 0.076 18.84 0.077 18.88 0.077 18.84 0.077 18.85 0.077 18.50 0.071 18.69 0.074 18.56 0.072 18.61 0.073 18.44 0.070 18.72 0.074 18.84 0.077 Measured E.R.P. Middle Ch. / Freq. 26740 819.0 dBm W 18.85 0.077 18.86 0.077 18.81 0.076 18.71 0.074 18.90 0.078 18.85 0.077 18.71 0.074 18.66 0.073 18.54 0.071 18.71 0.074 18.61 0.073 18.57 0.072 18.62 0.073 18.59 0.072 18.50 0.071 18.22 0.066 18.45 0.070 18.75 0.075 18.90 0.078 18.65 0.073 18.86 0.077 High Ch. / Freq. 26775 822.5 dBm W 18.79 0.076 18.49 0.071 18.52 0.071 18.79 0.076 18.57 0.072 18.29 0.067 18.78 0.076 18.86 0.077 18.82 0.076 18.72 0.074 18.73 0.075 18.58 0.072 18.60 0.072 18.79 0.076 18.23 0.067 18.28 0.067 18.54 0.071 18.51 0.071 18.73 0.075 18.48 0.070 18.61 0.073 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 43 REPORT No.SZ23120301W03 LTE Band 26 BW [MHz] Modulation RB Size Channel Frequency (MHz) 1.4 QPSK 1 1.4 QPSK 1 1.4 QPSK 1 1.4 QPSK 3 1.4 QPSK 3 1.4 QPSK 3 1.4 QPSK 6 1.4 16QAM 1 1.4 16QAM 1 1.4 16QAM 1 1.4 16QAM 3 1.4 16QAM 3 1.4 16QAM 3 1.4 16QAM 6 1.4 64QAM 1 1.4 64QAM 1 1.4 64QAM 1 1.4 64QAM 3 1.4 64QAM 3 1.4 64QAM 3 1.4 64QAM 6 RB Offset 0 3 5 0 1 3 0 0 3 5 0 1 3 0 0 3 5 0 1 3 0 Low Ch. / Freq. 26697 814.7 dBm W 18.69 0.074 18.79 0.076 18.72 0.074 18.79 0.076 18.85 0.077 18.81 0.076 18.83 0.076 18.61 0.073 18.72 0.074 18.68 0.074 18.49 0.071 18.35 0.068 18.63 0.073 18.41 0.069 18.45 0.070 18.59 0.072 18.49 0.071 18.62 0.073 18.50 0.071 18.50 0.071 18.62 0.073 Measured E.R.P. Middle Ch. / Freq. 26740 819.0 dBm W 18.81 0.076 18.91 0.078 18.71 0.074 18.47 0.070 18.76 0.075 18.84 0.077 18.80 0.076 18.42 0.070 18.89 0.077 18.53 0.071 18.86 0.077 18.93 0.078 18.91 0.078 18.96 0.079 18.61 0.073 18.71 0.074 18.56 0.072 18.95 0.079 18.97 0.079 18.97 0.079 18.90 0.078 High Ch. / Freq. 26783 823.3 dBm W 18.70 0.074 18.78 0.076 18.70 0.074 18.83 0.076 18.93 0.078 18.76 0.075 18.64 0.073 18.67 0.074 18.53 0.071 18.69 0.074 18.60 0.072 18.69 0.074 18.72 0.074 18.58 0.072 18.56 0.072 18.63 0.073 18.39 0.069 18.72 0.074 18.68 0.074 18.59 0.072 18.68 0.074 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 43 2.2. Occupied Bandwidth REPORT No.SZ23120301W03 2.2.1. Requirement According to FCC section 2.1049, the occupied bandwidth is the frequency bandwidth such that, below its lower and above its upper frequency limits, the mean powers radiated are each equal to 0.5 percent of the total mean power radiated by a given emission. Occupied bandwidth is also known as the 99% emission bandwidth. 2.2.2. Test Description The EUT is coupled to the Spectrum Analyzer (SA) and the System Simulator (SS) with Attenuators through the Power Splitter; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. The EUT is commanded by the SS to operate at the maximum output power. A call is established between the EUT and the SS. 2.2.3. Test procedure KDB 971168 D01v03 Section 4.1 and ANSI/TIA-603-E-2016. 2.2.4. Test Result MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 43 REPORT No.SZ23120301W03 LTE Band B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 Part90 B26 BW(MHz) 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 3 3 3 3 3 3 3 3 3 Channel Level Low Low Low Mid Mid Mid High High High Low Low Low Mid Mid Mid High High High Channel 26697 26697 26697 26740 26740 26740 26783 26783 26783 26705 26705 26705 26740 26740 26740 26775 26775 26775 Frequency (MHz) 814.7 814.7 814.7 819 819 819 823.3 823.3 823.3 815.5 815.5 815.5 819 819 819 822.5 822.5 822.5 Modulation QPSK 16QAM 64QAM QPSK 16QAM 64QAM QPSK 16QAM 64QAM QPSK 16QAM 64QAM QPSK 16QAM 64QAM QPSK 16QAM 64QAM 99% BW (MHz) 1.0880 1.0996 1.0972 1.0928 1.0960 1.0975 1.0926 1.0938 1.0981 2.6879 2.6977 2.6959 2.6925 2.6943 2.6881 2.6908 2.6929 2.6949 26dB BW (MHz) 1.2866 1.2970 1.2958 1.2588 1.2754 1.2845 1.2660 1.2827 1.2844 2.9291 2.9304 2.9179 2.9236 2.9212 2.9147 2.9234 2.9321 2.9230 Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 43 Part90 B26 Part90 5 B26 Part90 5 B26 Part90 5 B26 Part90 5 B26 Part90 5 B26 Part90 5 B26 Part90 5 B26 Part90 5 B26 Part90 5 B26 Part90 10 B26 Part90 10 B26 Part90 10 B26 Part90 10 B26 Part90 10 B26 Part90 10 B26 Part90 10 B26 Part90 10 B26 Part90 10 REPORT No.SZ23120301W03 Low Low Low Mid Mid Mid High High High Low Low Low Mid Mid Mid High High High 26715 26715 26715 26740 26740 26740 26765 26765 26765 26740 26740 26740 26740 26740 26740 26740 26740 26740 816.5 816.5 816.5 819 819 819 821.5 821.5 821.5 819 819 819 819 819 819 819 819 819 QPSK 4.5013 4.9258 PASS 16QAM 4.5011 4.8863 PASS 64QAM 4.5081 4.9104 PASS QPSK 4.4983 4.9174 PASS 16QAM 4.5028 4.9011 PASS 64QAM 4.5052 4.9430 PASS QPSK 4.4953 4.9179 PASS 16QAM 4.4985 4.8845 PASS 64QAM 4.4973 4.9094 PASS QPSK 8.9986 9.7361 PASS 16QAM 8.9654 9.6996 PASS 64QAM 8.9925 9.7536 PASS QPSK 8.9859 9.7592 PASS 16QAM 8.9715 9.7255 PASS 64QAM 8.9824 9.7523 PASS QPSK 9.0086 9.7326 PASS 16QAM 8.9624 9.7194 PASS 64QAM 8.9896 9.7882 PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 43 REPORT No.SZ23120301W03 B26 Part90 / 1.4MHz / QPSK/ Low CH B26 Part90 / 1.4MHz / 16QAM/ Low CH B26 Part90 / 1.4MHz / 64QAM/ Low CH B26 Part90 / 1.4MHz / QPSK/ Mid CH B26 Part90 / 1.4MHz / 16QAM/ Mid CH B26 Part90 / 1.4MHz / 64QAM/ Mid CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 43 REPORT No.SZ23120301W03 B26 Part90 / 1.4MHz / QPSK/ High CH B26 Part90 / 1.4MHz / 16QAM/ High CH B26 Part90 / 1.4MHz / 64QAM/ High CH B26 Part90 / 3MHz / QPSK/ Low CH B26 Part90 / 3MHz / 16QAM/ Low CH B26 Part90 / 3MHz / 64QAM/ Low CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 43 REPORT No.SZ23120301W03 B26 Part90 / 3MHz / QPSK/ Mid CH B26 Part90 / 3MHz / 16QAM/ Mid CH B26 Part90 / 3MHz / 64QAM/ Mid CH B26 Part90 / 3MHz / QPSK/ High CH B26 Part90 / 3MHz / 16QAM/ High CH B26 Part90 / 3MHz / 64QAM/ High CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 43 REPORT No.SZ23120301W03 B26 Part90 / 5MHz / QPSK/ Low CH B26 Part90 / 5MHz / 16QAM/ Low CH B26 Part90 / 5MHz / 64QAM/ Low CH B26 Part90 / 5MHz / QPSK/ Mid CH B26 Part90 / 5MHz / 16QAM/ Mid CH B26 Part90 / 5MHz / 64QAM/ Mid CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 43 REPORT No.SZ23120301W03 B26 Part90 / 5MHz / QPSK/ High CH B26 Part90 / 5MHz / 16QAM/ High CH B26 Part90 / 5MHz / 64QAM/ High CH B26 Part90 / 10MHz / QPSK/ Low CH B26 Part90 / 10MHz / 16QAM/ Low CH B26 Part90 / 10MHz / 64QAM/ Low CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 23 of 43 REPORT No.SZ23120301W03 B26 Part90 / 10MHz / QPSK/ Mid CH B26 Part90 / 10MHz / 16QAM/ Mid CH B26 Part90 / 10MHz / 64QAM/ Mid CH B26 Part90 / 10MHz / QPSK/ High CH B26 Part90 / 10MHz / 16QAM/ High CH B26 Part90 / 10MHz / 64QAM/ High CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 24 of 43 2.3. Frequency Stability REPORT No.SZ23120301W03 2.3.1. Requirement According to FCC section 2.1055 & 90.213, the frequency stability shall be sufficient to ensure that the fundamental emission stays within the authorized frequency block. According to FCC section 2.1055, the test conditions are: (a) The temperature is varied from -30°C to +50°C at intervals of not more than 10°C. (b) For hand carried battery powered equipment, the primary supply voltage is reduced to the battery operating end point which shall be specified by the manufacture. The supply voltage shall be measured at the input to the cable normally provided with the equipment, or at the power supply terminals if cables are not normally provided. Note: The operating temperature of EUT is from -10°C to 55°C, which are specified by the applicant. 2.3.2. Test Description The EUT which is powered by the DC Power Supply directly, is located in the Temperature Chamber. The EUT is commanded by the System Simulator (SS) to operate at the maximum output power. A call is established between the EUT and the SS via a Common Antenna. 2.3.3. Test procedure KDB 971168 D01v03 Section 9.0 and ANSI/TIA-603-E-2016. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 25 of 43 REPORT No.SZ23120301W03 2.3.4. Test Result The nominal, highest and lowest extreme voltages are separately 3.80V, 4.35V and 3.50V, which are specified by the applicant; the normal temperature here used is 20°C. LTE Band 26, 64QAM, Channel 26740, Frequency 819MHz Limit =±2.5ppm Voltage (%) Power (VDC) Temp (°C) Fre. Dev. (Hz) Deviation (ppm) Result Normal +20(Ref) 20 0.024 Normal -10 16 0.020 Normal 0 15 0.018 Normal +10 17 0.021 Normal 3.85 +20 15 0.018 Normal +30 -15 -0.018 PASS Normal +40 22 0.027 Normal +50 -6 -0.007 Normal +55 14 0.017 High 4.40 +20 19 0.023 BATT.ENDPOINT 3.60 +20 13 0.016 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 26 of 43 2.4. Conducted Spurious Emissions REPORT No.SZ23120301W03 2.4.1. Requirement According to FCC section 2.1051, the power of any emission outside of the authorized operating frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43+10*log(P)dB. This calculated to be -13dBm. 2.4.2. Test Description The EUT is coupled to the Spectrum Analyzer (SA) and the System Simulator (SS) with Attenuators through the Power Splitter; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. The EUT is commanded by the SS to operate at the maximum output power. A call is established between the EUT and the SS. 2.4.3. Test procedure KDB 971168 D01v03 Section 6.0 and ANSI/TIA-603-E-2016. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 27 of 43 2.4.4. Test Result REPORT No.SZ23120301W03 B26 Part90 / 1.4MHz / Low CH / QPSK B26 Part90 / 1.4MHz / Mid CH / QPSK B26 Part90 / 1.4MHz / High CH / QPSK B26 Part90 / 3MHz / Low CH / QPSK B26 Part90 / 3MHz / Mid CH / QPSK B26 Part90 / 3MHz / High CH / QPSK MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 28 of 43 REPORT No.SZ23120301W03 B26 Part90 / 5MHz / Low CH / QPSK B26 Part90 / 5MHz / Mid CH / QPSK B26 Part90 / 5MHz / High CH / QPSK B26 Part90 / 10MHz / Low CH / QPSK B26 Part90 / 10MHz / Mid CH / QPSK B26 Part90 / 10MHz / High CH / QPSK MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 29 of 43 2.5. Band Edge REPORT No.SZ23120301W03 2.5.1. Requirement Band26 According to FCC section 90.961(a), the power of any emission outside of the authorized operating frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. 2.5.2. Test Description The EUT is coupled to the Spectrum Analyzer (SA) and the System Simulator (SS) with Attenuators through the Power Splitter; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. The EUT is commanded by the SS to operate at the maximum output power. A call is established between the EUT and the SS. 2.5.3. Test procedure KDB 971168 D01v03 Section 6.0 and ANSI/TIA-603-E-2016. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 30 of 43 2.5.4. Test Result REPORT No.SZ23120301W03 B26 Part90 / 1.4MHz / Low CH / QPSK / 1 RB B26 Part90 / 1.4MHz / Low CH / QPSK / FULL RB B26 Part90 / 1.4MHz / High CH / QPSK / 1 RB B26 Part90 / 1.4MHz / High CH / QPSK / FULL RB B26 Part90 / 3MHz / Low CH / QPSK / 1 RB B26 Part90 / 3MHz / Low CH / QPSK / FULL RB MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 31 of 43 REPORT No.SZ23120301W03 B26 Part90 / 3MHz / High CH / QPSK / 1 RB B26 Part90 / 3MHz / High CH / QPSK / FULL RB B26 Part90 / 5MHz / Low CH / QPSK / 1 RB B26 Part90 / 5MHz / Low CH / QPSK / FULL RB B26 Part90 / 5MHz / High CH / QPSK / 1 RB B26 Part90 / 5MHz / High CH / QPSK / FULL RB MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 32 of 43 REPORT No.SZ23120301W03 B26 Part90 / 10MHz / Low CH / QPSK / 1 RB B26 Part90 / 10MHz / Low CH / QPSK / FULL RB B26 Part90 / 10MHz / High CH / QPSK / 1 RB B26 Part90 / 10MHz / High CH / QPSK / FULL RB MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 33 of 43 2.6. Radiated Spurious Emissions REPORT No.SZ23120301W03 2.6.1. Requirement According to FCC section 2.1051, the power of any emission outside of the authorized operating frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43+10*log(P)dB. This calculated to be -13dBm. 2.6.2. Test Description (For the test frequency from 30MHz to1GHz) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 34 of 43 REPORT No.SZ23120301W03 (For the test frequency above 1GHz) The EUT is located in a 3m Full-Anechoic Chamber, the cable loss, air loss and so on of the site as factors are pre-calibrated using the "Substitution" method, and calculated to correct the reading. A call is established between the EUT and the SS via a Common Antenna. The EUT is commanded by the SS to operate at the maximum and minimum output power, and only the test result of the maximum output power was recorded. In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground and the Turn Table is actuated to turn from 0° to 360°to determine the maximum value of the radiated power. The emission levels at both horizontal and vertical polarizations should be tested. The Filters consists of Notch Filters and High Pass Filter. Note: when doing measurements above 1GHz, the EUT has been within the 3dB cone width of the horn antenna during horizontal antenna. 2.6.3. Test procedure KDB 971168 D01v03 Section 5.8 and ANSI/TIA-603-E-2016. For measurements below 1 GHz the resolution bandwidth is set to 100 kHz for peak detection measurements. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 35 of 43 REPORT No.SZ23120301W03 2.6.4. Test Result The measurement frequency range is from 30MHz to the 10th harmonic of the fundamental frequency. The Turn Table is actuated to turn from 0° to 360°, and both horizontal and vertical polarizations of the Test Antenna are used to find the maximum radiated power. The lowest, middle and highest channels are tested to verify the out of band emissions. The substitution corrections are obtained as described below: ASUBST = PSUBST_TX - PSUBST_RX - LSUBST_CABLES + GSUBST_TX_ANT ATOT = LCABLES + ASUBST Where ASUBST is the final substitution correction including receive antenna gain. PSUBST_TX is signal generator level, PSUBST_RX is receiver level, LSUBST_CABLES is cable losses including TX cable, GSUBST_TX_ANT is substitution antenna gain. ATOT is total correction factor including cable loss and substitution correction During the test, the data of ATOT was added in the test spectrum analyze, so spectrum analyze reading is the final values which contain the data of ATOT. Note1: The power of the EUT transmitting frequency should be ignored. Note2: All Spurious Emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note3: All bandwidth and modulation were considered and evaluated respectively by performing full test for each band, only the worst cases (Max Bandwidth and QPSK mode) were recorded in this test report. Note 4: N/A means the frequency is the basic frequency or the base station frequency, they are no need to verdict. Note 5: The amplitude of emissions(18GHz to 10th harmonics) which are attenuated more than 20 dB below the limit are not be reported. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 36 of 43 REPORT No.SZ23120301W03 LTE Band 26, 5MHz BW, Low Channel, QPSK No. Fre.(MHz) 1 816.670 2 863.230 3 1313.085 4 2210.084 5 7186.789 6 9148.863 PK (dBm) -40.41 -50.16 -39.71 -39.62 -40.89 -38.58 Limit (dBm) -13.00 -13.00 -13.00 -13.00 -13.00 -13.00 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict N/A N/A PASS PASS PASS PASS No. Fre.(MHz) 1 814.730 2 863.230 3 1298.359 4 2219.048 5 7190.480 6 9501.409 PK (dBm) -46.60 -60.38 -40.34 -40.22 -40.63 -38.12 Limit (dBm) -13.00 -13.00 -13.00 -13.00 -13.00 -13.00 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict N/A N/A PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 37 of 43 REPORT No.SZ23120301W03 LTE Band 26, 5MHz BW, Mid Channel, QPSK No. Fre.(MHz) 1 816.670 2 865.170 3 1275.950 4 2198.559 5 7240.316 6 9634.306 PK (dBm) -40.68 -48.54 -40.25 -39.62 -41.03 -37.47 Limit (dBm) -13.00 -13.00 -13.00 -13.00 -13.00 -13.00 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict N/A N/A PASS PASS PASS PASS No. Fre.(MHz) 1 816.670 2 866.140 3 1308.603 4 2249.780 5 7227.396 6 9054.728 PK (dBm) -46.38 -59.28 -39.92 -39.80 -40.91 -38.64 Limit (dBm) -13.00 -13.00 -13.00 -13.00 -13.00 -13.00 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict N/A N/A PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 38 of 43 REPORT No.SZ23120301W03 LTE Band 26, 5MHz BW, High Channel, QPSK No. Fre.(MHz) 1 822.490 2 865.170 3 1276.591 4 2243.377 5 7255.083 6 9623.231 PK (dBm) -39.49 -47.91 -39.54 -39.58 -40.24 -38.01 Limit (dBm) -13.00 -13.00 -13.00 -13.00 -13.00 -13.00 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict N/A N/A PASS PASS PASS PASS No. Fre.(MHz) 1 823.460 2 865.170 3 1644.738 4 2202.401 5 7236.625 6 9303.910 PK (dBm) -45.44 -59.72 -40.42 -39.60 -41.12 -37.98 Limit (dBm) -13.00 -13.00 -13.00 -13.00 -13.00 -13.00 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict N/A N/A PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 39 of 43 Annex A Test Uncertainty REPORT No.SZ23120301W03 Where relevant, the following measurement uncertainty levels have been estimated for test performed on the EUT as specified in CISPR 16-1-2: Test items Uncertainty Output Power ±2.22 dB Bandwidth ±5% Conducted Spurious Emission ±2.77 dB Band Edge ±2.77 dB Equivalent Isotropic Radiated Power ±2.22 dB Radiated Spurious Emissions ±6 dB This uncertainty represent an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 40 of 43 REPORT No.SZ23120301W03 Annex B Testing Laboratory Information 1. Identification of the Responsible Testing Laboratory Laboratory Name: Laboratory Address: Telephone: Facsimile: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 2. Identification of the Responsible Testing Location Name: Address: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China 3. Facilities and Accreditations All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 41 of 43 REPORT No.SZ23120301W03 4. Test Equipments Utilized 4.1 Conducted Test Equipments Equipment Name Serial No. EXA Signal Analyzer MY51511149 Communication Test Station 6200995016 Temperature S022177101 Chamber 00089002 Type N9020A MT8820C KMT-36LF 1A0 Manufacturer Agilent Anritsu KOMEG Cal. Date 2023.06.21 Due Date 2024.06.20 2023.09.19 2024.09.18 2023.09.19 2024.09.18 4.2 List of Software Used Description Morlab FCC LTE Test System MORLAB EMCR Manufacturer MORLAB MORLAB Software Version V6.45 V1.2 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 42 of 43 REPORT No.SZ23120301W03 4.3 Radiated Test Equipments Equipment Name Serial No. Type Manufacturer Cal. Date Due Date System Simulator 152038 CMW500 R&S 2023.10.17 2024.10.16 Receiver Test Antenna - Bi-Log Test Antenna - Horn RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-40GHz) Preamplifier (10MHz-6GHz) Preamplifier (2GHz-18GHz) Preamplifier (18GHz-40GHz) Notch Filter Anechoic Chamber MY54130016 9163-519 9120D-963 MRE001 MRE002 MRE003 22290045 22290046 46732 61171/61172 DS77209 N/A N/A N9038A VULB 9163 BBHA 9120D PE330 CLU18 CLU18 QA360-40-KK0.5 QA360-40-KK F-2 S10M100L380 2 S020180L320 3 DCLNA0118-4 0C-S WRCGV -LTE 26 9m*6m*6m Agilent Schwarzbeck Schwarzbeck Pasternack Pasternack Pasternack Qualwave Qualwave LUCIX CORP. LUCIX CORP. Decentest Wainwright CRT 2023.06.21 2023.07.01 2023.06.27 2023.06.27 2023.06.27 2023.06.27 2023.07.04 2023.07.04 2023.07.04 2023.06.27 2023.06.27 N/A 2022.05.10 2024.06.20 2024.06.30 2024.06.26 2024.06.26 2024.06.26 2024.06.26 2024.07.03 2024.07.03 2024.07.03 2024.06.26 2024.06.26 N/A 2025.05.09 END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 43 of 43Acrobat Distiller 11.0 (Windows)