Hangzhou Huacheng Network Technology Co.,Ltd. IPC-F42FX CONSUMER CAMERA 2AVYF-IPC-F42FX 2AVYFIPCF42FX ipc f42fx
RF EXPOSURE REPORT For CONSUMER CAMERA MODEL NUMBER: IPC-F42FP ADDTIONAL MODEL NUMBER: IPC-TF42F-LC; IPC-F42F-LC; IPC-F42FP-imou; IPC-F42FN-imou; IPC-F42FN; IPC-F42F; LC-TF2F-4M; LC-A32F-4M; F42F; IPC-TF42F-0280B-LC; IPC-TF42F-0360B-LC; IPC-TF42F-0600B-LC; IPC-F42F0280B-LC; IPC-F42F-0360B-LC; IPC-F42F-0600B-LC; IPC-F42FP-0280B-imou; IPC-F42FP-0360B-imou; IPC-F42FP-0600B-imou; IPC-F42FN-0280B-imou; IPC-F42FN-0360B-imou; IPC-F42FN-0600B-imou; IPC-F42FP-0280B; IPC-F42FP0360B; IPC-F42FP-0600B; IPC-F42FN-0280B; IPC-F42FN-0360B; IPC-F42FN-0600B PROJECT NUMBER: 4789796034 REPORT NUMBER: 4789796034-5 FCC ID: 2AVYF-IPC-F42FX ISSUE DATE: Feb. 20, 2021 Prepared for Hangzhou Huacheng Network Technology Co., Ltd. Prepared by UL-CCIC COMPANY LIMITED No. 2, Chengwan Road, Suzhou Industrial Park, People's Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com The results reported herein have been performed in accordance with the laboratory's terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. Rev. V0 Issue Date 02/20/2021 REPORT No.: 4789796034-5 Page 2 of 7 Revisions Initial Issue Revised By UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. REPORT No.: 4789796034-5 Page 3 of 7 TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. REQUIREMENT ................................................................................................................. 6 UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. REPORT No.: 4789796034-5 Page 4 of 7 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Address: Hangzhou Huacheng Network Technology Co., Ltd. No.2930, Nanhuan Road, Binjiang District, Hangzhou, China Manufacturer Information Company Name: Address: Hangzhou Huacheng Network Technology Co., Ltd. No.2930, Nanhuan Road, Binjiang District, Hangzhou, China EUT Description Product Name: Model Name: Additional No. : Sample Number: Data of Receipt Sample: Date Tested: CONSUMER CAMERA IPC-F42FP IPC-TF42F-LC; IPC-F42F-LC; IPC-F42FP-imou; IPC-F42FNimou; IPC-F42FN; IPC-F42F; LC-TF2F-4M; LC-A32F-4M; F42F; IPC-TF42F-0280B-LC; IPC-TF42F-0360B-LC; IPC-TF42F0600B-LC; IPC-F42F-0280B-LC; IPC-F42F-0360B-LC; IPCF42F-0600B-LC; IPC-F42FP-0280B-imou; IPC-F42FP-0360Bimou; IPC-F42FP-0600B-imou; IPC-F42FN-0280B-imou; IPC-F42FN-0360B-imou; IPC-F42FN-0600B-imou; IPC-F42FP0280B; IPC-F42FP-0360B; IPC-F42FP-0600B; IPC-F42FN0280B; IPC-F42FN-0360B; IPC-F42FN-0600B 3607003 Jan. 19, 2021 Jan. 19, 2021~ Feb. 18, 2021 APPLICABLE STANDARDS STANDARD FCC Guidelines for Human Exposure IEEE C95.1 TEST RESULTS Complies Prepared By: Reviewed By: Jason Yang Engineer Authorized By: Tom Tang Engineer Project Associate Chris Zhong Laboratory Leader UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. REPORT No.: 4789796034-5 Page 5 of 7 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with KDB 447498 D01 General RF Exposure Guidance v06 and FCC Guidelines for Human Exposure IEEE C95.1. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4829.01) UL-CCIC COMPANY LIMITED has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1247) UL-CCIC COMPANY LIMITED has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. IC (IC Designation No.: 25056) UL-CCIC COMPANY LIMITED has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. Note 1: All tests measurement facilities use to collect the measurement data are located at No. 2, Chengwan Road, Suzhou Industrial Park, Suzhou 215122, People's Republic of China Note 2: For below 30MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. These measurements below 30MHz had been correlated to measurements performed on an OFS. Note 3: The test anechoic chamber in UL-CCIC COMPANY LIMITED had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. REPORT No.: 4789796034-5 Page 6 of 7 4. REQUIREMENT LIMIT Limits for General Population/Uncontrolled Exposure Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) 0.3-1.34 1.34-30 30-300 300-1500 1500-100,000 Electric Field Strength (E) (V/m) 614 824/f 27.5 --- Magnetic Field Strength (H) (A/m) 1.63 2.19/f 0.073 --- Power Density (S) (mW/cm2) (100)* (180/f2)* 0.2 f/150 1.0 Note 1: f = frequency in MHz, * means Plane-wave equivalent power density Averaging Time |E|2, |H|2 or S (minutes) 30 30 30 30 30 Note 2: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Note 3: The limit value 1.0mW/cm2 is available for this EUT. MPE CALCULATION METHOD 2 S =PG/(4R ) where: S = power density (in appropriate units, e.g. mW/ cm2) P = power input to the antenna (in appropriate units, e.g., mW) (the measured power value refer to the tune-up document) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.. REPORT No.: 4789796034-5 Page 7 of 7 CALCULATED RESULTS Radio Frequency Radiation Exposure Evaluation: 1) For SISO mode: Mode Tune-up Power(P) WIFI (Worst case) Antenna Gain Power Density Limit 11B (dBm) (mW) (dBi) 19.0 79.43 1.79 Note: The calculated distance is 20cm. (Numeric) 1.51 (mW/cm2) 0.0239 (mW/cm2) 1 Test Result -- Complies 2) For MIMO mode: Mode Tune-up Power(P) WIFI (Worst case) Antenna Gain Power Density Limit 11N HT20 MIMO (dBm) 20 (mW) 100 (dBi) 4.80 Note: The calculated distance is 20cm. (Numeric) 3.02 (mW/cm2) 0.0601 (mW/cm2) 1 Test Result -- Complies END OF REPORT UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED..Microsoft Word 适用于 Microsoft 365