ZTE Corporation MF296C 4G Wireless Router with WiFi, NFC, GSM, WCDMA, and LTE SRQ-MF296C SRQMF296C mf296c
Certificate #5505.02 TEST REPORT FOR NFC TESTING Report No: SRTC2022-9004(F)-22080401(N) Product Name: 4G Wireless Router Product Model: MF296C Applicant: ZTE Corporation Manufacturer: ZTE Corporation Specification: CFR 47, Part 15, Sections 15.225, 15.207, 15.215 FCC ID: SRQ-MF296C The State Radio_monitoring_center Testing Center (SRTC) 15th Building, No.30, Shixing Street, Shijingshan District, Beijing, P.R.China Tel: 86-10-57996183 Fax: 86-10-57996388 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C CONTENTS 1. GENERAL INFORMATION................................................................................................................................... 2 1.1 Notes of the test report................................................................................................................................ 2 1.2 Information about the testing laboratory................................................................................................... 2 1.3 Applicant's details......................................................................................................................................... 2 1.4 Manufacturer's details..................................................................................................................................2 1.5 Test environment.......................................................................................................................................... 3 2. DETAILS OF EQUIPMENT UNDER TEST........................................................................................................ 3 2.1 Final equipment builds status................................................................................................................ 3 2.2 Support equipment.................................................................................................................................... 3 3. REFERENCE SPECIFICATION........................................................................................................................... 4 4. KEY TO NOTES AND RESULT CODES............................................................................................................ 4 5. RESULT SUMMARY.............................................................................................................................................. 5 6. TEST RESULTS...................................................................................................................................................... 6 6.1 Occupied Bandwidth................................................................................................................................. 6 6.2 In-band emission........................................................................................................................................ 8 6.3 Radiated emission 9 kHz to 30 MHz....................................................................................................10 6.4 Radiated emission 30 MHz to 1 GHz................................................................................................... 12 6.5 Carrier frequency stability..................................................................................................................... 14 7. MEASUREMENT UNCERTAINTIES.................................................................................................................15 8. TEST EQUIPMENT.............................................................................................................................................. 15 ANNEX A Test Result...........................................................................................................................................16 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 1 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 1. GENERAL INFORMATION 1.1 Notes of the test report The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written permission of The State Radio_monitoring_center Testing Center (SRTC).The test results relate only to individual items of the samples which have been tested. The certification and accreditation identifiers used in this report shall not be applicable to the tested or calibrated samples thereof. The manufacturer shall not mark the tested samples or items (or a separate part of the item) with the identifiers of certification and accreditation to mislead relevant parties about the tested samples or items. 1.2 Information about the testing laboratory Company: Test Site 1: Test Site 2: City: Country or Region: Contacted person: Tel: Fax: Email: Designation Number: Registration number: The State Radio_monitoring_center Testing Center (SRTC) 15th Building, No.30 Shixing Street, Shijingshan District No.80, Zhaojiachang, Beizang, Daxing District Beijing P.R.China Liu Jia +86 10 57996183 +86 10 57996388 liujiaf@srtc.org.cn CN1267 239125 1.3 Applicant's details Company: Address: ZTE Corporation ZTE Plaza, #55 Keji Road South, Hi-Tech, Industrial Park, Nanshan District,Shenzhen, Guangdong, 518057, P.R.China 1.4 Manufacturer's details Company: Address: ZTE Corporation ZTE Plaza, #55 Keji Road South, Hi-Tech, Industrial Park, Nanshan District,Shenzhen, Guangdong, 518057, P.R.China The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 2 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 1.5 Test environment Date of Receipt of test sample at SRTC: Testing Start Date: Testing End Date: Environmental Data: Ambient: Maximum Extreme: Minimum Extreme: Normal Supply Voltage (V d.c.): Maximum Extreme Supply Voltage (V d.c.): Minimum Extreme Supply Voltage (V d.c.): 2022-08-04 2022-08-05 2022-08-31 Temperature (°C) 25 55 -20 Humidity (%) 40 ----- 12.0 13.2 10.8 2. DETAILS OF EQUIPMENT UNDER TEST 2.1 Final equipment builds status Operating Frequency Antenna Type Modulation Type Power Supply Software Revision: Hardware Revision: IMEI: 13.56 MHz Internal antenna ASK Charger CR_LAMF296CV1.0.0B01 mp6A 860389060007859 2.2 Support equipment The following support equipment was used to exercise the EUT during testing: The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 3 of 19 V3.0.0 3. REFERENCE SPECIFICATION No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C Specification 2.202(a) 15.225(a)-(c) 15.225(d) 15.205(b) 15.225(d) 15.225(e) ANSI C63.10 Version 2021 2021 2021 2021 2021 2013 Title Occupied bandwidth In-band emission Radiated emission 9 kHz to 30 MHz Radiated emission 30 MHz to 1 GHz Carrier frequency stability Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices 4. KEY TO NOTES AND RESULT CODES Code PASS FAIL N/A N/T Meaning Test result shows that the requirements of the relevant specification have been met. Test result shows that the requirements of the relevant specification have not been met. Test case is not applicable. Test case is not tested. The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 4 of 19 V3.0.0 5. RESULT SUMMARY 2 Item 1 Occupied bandwidth 2 Conducted emission test 3 In-band emission 4 Radiated emission 9 kHz to 30 MHz 5 Radiated emission 30 MHz to 1 GHz 6 Carrier frequency stability 7 AC Power line Conducted Emission Test Site 2: No.80, Zhaojiachang, Beizang, Daxing District No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C Results Pass N/T Pass Pass Pass Pass Pass This Test Report Is Approved by: Mr. Liu Wei Review by: Mr. Guo Yu Tested and Issued by: Mr. Dong Qifeng Approved date: 20220819 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 5 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6. TEST RESULTS 6.1 Occupied Bandwidth 6.1.1 Test conditions and test configuration The occupied bandwidth according to CFR 47 Part 2, section 2.202(a), is measured as the 99% emission bandwidth, i.e. below its lower and above its upper frequency limits, the mean powers radiated are each equal to 0.5% of the total mean power radiated by a given emission. The occupied bandwidth according to ANSI C63.10, section 6.9.1; is measured as the frequency range defined by the points that are 20 dB down relative to the maximum level of the modulated carrier. The span range of the spectrum analyzer display shall be between two times and five times of the occupied bandwidth. The resolution bandwidth of the spectrum analyzer should be approximately 1% to 5% of the occupied bandwidth, unless otherwise specified, depending on the applicable requirement. The video bandwidth shall be at least three times greater than the resolution bandwidth. The dynamic range of the spectrum analyzer at the selected resolution bandwidth shall be more than 10 dB below the target "dB down" (attenuation) requirement. If antenna is detachable bandwidth measurements shall be performed at the antenna connector (conducted measurement) when the transmitter is adjusted in accordance with the tune-up procedure, if applicable. The RF output terminals are connected to a spectrum analyzer. If required, a resistive matching network equal to the impedance specified or employed for the antenna is used as well as dc block and appropriate attenuators (50 Ohms). The electrical characteristics of the radio frequency load attached to the output terminals shall be stated, if applicable. If radiated measurements are performed the same test setups and instruments are used as with radiated emission measurements for the appropriate frequency range. The analyzer settings are specified by the test description of the appropriate test record(s). The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 6 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6.1.2 Test limit The 20 dB bandwidth shall be specified in operating frequency band. 6.1.3 Test data The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 7 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6.2 In-band emission 6.2.1 Test conditions and test configuration In the case of a transmitter with an integral or dedicated antenna, the radiated H-field is defined in the direction of maximum field strength under specified conditions of measurement. The measurements shall be made on an open field test site as specified in standard. Any measured values shall be at least 6 dB above the ambient noise level. The H-field produced by the equipment shall be measured at standard distance of 3 m. Where this is not practical, e.g. due to physical size of the equipment including the antenna or with use of special field cancelling antenna, then other distances may be used. When another distance is used, the distance used and the field strength value measured shall be stated in the test report. In this case, the measured value at actual test distance shall be extrapolated to 3 m and stated in the test report. The H-field is measured with a shielded loop antenna connected to a measurement receiver. The measuring bandwidth and detector type of the measurement receiver shall be in accordance with standard. The equipment under test shall be operated with modulation as defined in standard. EUT MAST 3m The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 8 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6.2.2 Test limit (a) The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed 15,848 microvolts/meter at 30 meters. (b) Within the bands 13.410-13.553 MHz and 13.567-13.73 MHz, the field strength of any emissions shall not exceed 334 microvolts/meter at 30 meters. (c) Within the bands 13.110-13.43 MHz and 13.710-14.03 MHz the field strength of any emissions shall not exceed 106 microvolts/meter at 30 meters. 6.2.3 Test data The test results are shown in Appendix A . The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 9 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6.3 Radiated emission 9 kHz to 30 MHz 6.3.1 Test conditions and test configuration The measurements shall be made on an open field test site as specified in standard. Any measured values shall be at least 6 dB above the ambient noise level. The H-field produced by the equipment shall be measured at standard distance of 3 m. Where this is not practical, e.g. due to physical size of the equipment including the antenna or with use of special field cancelling antenna, then other distances may be used. When another distance is used, the distance used and the field strength value measured shall be stated in the test report. In this case, the measured value at actual test distance shall be extrapolated to 3 m and stated in the test report. The H-field is measured with a shielded loop antenna connected to a measurement receiver. The measuring bandwidth and detector type of the measurement receiver shall be in accordance with standard. The equipment under test shall be operated with modulation as defined in standard. EUT MAST 3m The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 10 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6.3.2 Test limit (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§15.231 and 15.241. 6.3.3 Test data The test results are shown in Appendix A . The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 11 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6.4 Radiated emission 30 MHz to 1 GHz 6.4.1 Test conditions and test configuration The measurements shall be made on an open field test site as specified in standard. Any measured values shall be at least 6 dB above the ambient noise level. The H-field produced by the equipment shall be measured at standard distance of 3 m. Where this is not practical, e.g. due to physical size of the equipment including the antenna or with use of special field cancelling antenna, then other distances may be used. When another distance is used, the distance used and the field strength value measured shall be stated in the test report. In this case, the measured value at actual test distance shall be extrapolated to 3 m and stated in the test report. The H-field is measured with a shielded loop antenna connected to a measurement receiver. The measuring bandwidth and detector type of the measurement receiver shall be in accordance with standard. The equipment under test shall be operated with modulation as defined in standard. EUT MAST 3m The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 12 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6.4.2 Test limit (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§15.231 and 15.241. 6.4.3 Test data The test results are shown in Appendix A . The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 13 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 6.5 Carrier frequency stability 6.5.1 Test conditions and test configuration (e) The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency over a temperature variation of -20 degrees to + 50 degrees C at normal supply voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For battery operated equipment, the equipment tests shall be performed using a new battery. 6.5.2 Test limit ±0.01% 6.5.3 Test data Voltage(V) Temperature(°C) 12.0 50 12.0 40 12.0 30 12.0 20 12.0 10 12.0 0 12.0 -10 12.0 -20 12.0 -30 13.2 20 10.8 20 Frequency (MHz) 13.56 13.56 13.56 13.56 13.56 13.56 13.56 13.56 13.56 13.56 13.56 Measured Frequency (MHz) 13.560004 13.560002 13.560003 13.560001 13.560005 13.560006 13.560003 13.560004 13.560002 13.560005 13.560002 Frequency Stability (ppm) 0.29 0.15 0.22 0.07 0.37 0.44 0.22 0.29 0.15 0.37 0.15 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 14 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 7. MEASUREMENT UNCERTAINTIES Item Occupied Bandwidth Carrier frequency stability Radiated Emission Measurements 9kHz30MHz Radiated Emission Measurements 30MHz1GHz Uncertainty figures are valid to a confidence level of 95%, k=2 Uncertainty 0.30 kHz 1×10-8 4.88 dB 4.86 dB 8. TEST EQUIPMENT No. Name/ Model 1. Spectrum Analyzer / FSV 2. Fully-Anechoic Chamber / 12.65m×8.03m×7.50m 3. Semi-Anechoic/Chamber / 23.18m×16.88m×9.60m 4. Turn table Diameter:1m 5. Turn table Diameter:5m 6. Antenna master FAC(MA4.0) 7. Antenna master SAC(MA4.0) 8. Shielding room / 9.080m×5.255m×3.525m 9. Double-Ridged Waveguide Horn Antenna / HF 907 10. Double-Ridged Waveguide Horn Antenna / HF 907 11. Ultra log antenna / HL562 12. Receive antenna /3160-09 13. EMI test receiver / ESI 40 14. EMI test receiver / ESCS30 15. Receive antenna / HL562 16. AMN / ENV216 17. WLAN AP WIA3300-20 18. Notebook E470c 19. EMI test software / EMC32 20. Loop antenna Manufacturer ROHDE & SCHWARZ FRANKONIA FRANKONIA FRANKONIA FRANKONIA MATURO MATURO FRANKONIA R&S R&S R&S SCHWARZ- BECK R&S R&S R&S R&S SKSpruce Lenovo R&S R&S S/N 101065 Cal date Cal Due date 2022.06.21 2023.06.20 ----- ----- ----- --- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- 100512 2022.06.21 2023.06.20 100513 100016 002058-002 100015 100029 100167 3560.6550.12 8152017060700339 2022.06.21 2022.06.21 2022.06.21 2022.06.21 2022.06.21 2022.06.21 2022.06.21 --- 2023.06.20 2023.06.20 2023.06.20 2023.06.20 2023.06.20 2023.06.20 2023.06.20 --- PF10UZW7 V10.20.01 100340 --- / 2022.8.20 --- / 2023.8.19 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 15 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C ANNEX A Test Result Radiated Emission Measurement Within the bands Loop antenna at 3M (a) The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed 15,848 microvolts/meter at 30 meters. (b) Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall not exceed 334 microvolts/meter at 30 meters. (c) Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of any emissions shall not exceed 106 microvolts/meter at 30 meters. Frequency (MHz) 13.110-13.410 13.410-13.553 13.553-13.567 13.567-13.710 13.710-14.010 Field strength (dBuV/m) 40.5 50.5 84 50.5 50.5 Measurement distance (meters) 30 30 30 30 30 Level in dBV/ 90 80 70 60 50 NFC 13.5 40 30 20 10 0 12.66 12.8 13 13.2 13.4 13.6 13.8 14 14.2 Frequency in MHz 14.46 Critical_Freqs Frequency (MHz) MaxPeak Limit Margin Bandwidth Pol (dBV/m) (dBV/m) (dB) (kHz) 13.560000 36.77 84.00 47.23 9.000 V Azimuth Corr. (deg) (dB) 0.0 -4.8 Comment The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 16 of 19 V3.0.0 outside of the 13.110-14.010 MHz band Loop antenna and Ultra log antenna at 3M No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C Frequency (MHz) 0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960 Field strength (dBuV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500 Measurement distance (meters) 300 30 30 3 3 3 3 Frequency (MHz) 33.201000 55.850500 139.173500 178.119000 550.259500 959.987500 Result (dBuV/m) 23.92 11.94 22.00 7.31 13.09 18.92 ARpl (dB) -20.4 -18.3 -22.7 -21.2 -9.7 -2.6 Pmea (dBuV/m) 44.32 30.24 44.70 28.51 22.79 21.52 Polarity Vertical Vertical Vertical Vertical Vertical Vertical Limit (dBuV/m) 40.00 40.00 40.00 40.00 40.00 40.00 The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 17 of 19 V3.0.0 Level in dBV/ No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C 50 45 40 35 30 25 20 15 10 5 0 -5 -10 -15 9k FCC_9kHz-30MHz 20 30 50 100k 200 300 500 1M 2M 3M 5M 10M 20 30M Frequency in Hz Frequency Range: 9kHz-30 MHz Detector: QP mode Full Spectrum 60 FCC PART15 50 40 30 20 10 0 Level in dBV/ 30M 50 60 80 100M 200 300 400 500 800 1G Frequency in Hz Frequency Range: 30MHz-1000 MHz Detector: QP mode The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 18 of 19 V3.0.0 No.: SRTC2022-9004(F)-22080401(N) FCC ID: SRQ-MF296C AC Power line Conducted Emission A "reference path loss" Corr.(dB) is established and the Lcable+ATT+VDF is the attenuation of " reference path loss", and including the cable loss, the attenuation of the attenuator, the voltage division factor of AMN. The measurement results are obtained as described below: Presult=Pmea+ Corr.(dB) Sample calculation: (51.05dBV) = (21.4 dBV) + (29.6 dB), the corresponding frequency is 0.150000MHz. Level in dB 70 65 60 55 50 45 40 35 30 25 150k AC Class B QP AC Class B AV 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M Frequency in Hz 20M 30M MEASUREMENT RESULT: Frequency (MHz) QuasiPeak (dBµV) 0.162793 0.439971 0.444236 0.448500 0.883457 0.891986 0.896250 1.275771 1.275771 1.420757 3.638186 4.162693 45.51 44.27 --43.83 --33.75 ----33.47 --30.93 --- L+N Line Average (dBµV) Limit (dBµV) ----35.01 --29.60 --29.77 30.28 --28.06 --30.07 65.32 57.06 46.98 56.90 46.00 56.00 46.00 46.00 56.00 46.00 56.00 46.00 Margin Line (dB) 19.81 N 12.79 L1 11.97 L1 13.07 L1 16.40 L1 22.25 N 16.23 N 15.72 L1 22.53 N 17.94 N 25.07 N 15.93 N Corr. (dB) 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.8 29.7 29.7 29.8 29.8 Pmea QuasiPe ak (dBµV) 15.81 14.57 --14.13 --4.05 ----3.77 --1.13 --- Pmea Average (dBµV) ----5.31 --- -0.1 --- 0.07 0.48 ---1.64 --0.27 ---End of Test Report--- The State Radio_monitoring_center Testing Center (SRTC) Tel: 86-10-57996183 Fax: 86-10-57996388 Page number: 19 of 19 V3.0.0WPS 文字