Instruction Manual for CAMDEN DOOR CONTROLS models including: CM-7536VR, CM-7536VR Column Switch with Sensor, CM-7536VR Column Switch, Column Switch, Column Switch with Sensor, Switch with Sensor, Switch, Sensor Switch
Print Materials - Camden Door Controls
File Info : application/pdf, 6 Pages, 1.48MB
DocumentDocumentElectrified Locks, Relays and Timers CM-7536VR Column Switch with Sensor INSTALLATION INSTRUCTIONS 1. DESCRIPTION 3. FEATURES Camden CM-7536VR Series Hands-Free ColumnTM switches uses active infra-red microburst sensor technology, designed for use in ADA compliant automatic door control applications and access control. The switches eliminate the spread of germs by avoiding physical contact and provide greater convenience when moving through the premises. All models are ROHS compliant with lead-free construction. Built-in remote LED switching allows for integration with third-party applications, such as guard and nurse station annunciators. Adjustable time delay from 0.5 to 20 seconds and an adjustable range from (2" to 8" / 5cm to 20cm). The CM-7536VR Series Hands-Free ColumnTM switches may be mounted to any flat wall surface, or to our Model CM-42 or CM-48 anodized aluminum or stainless-steel bollards. We provide necessary mounting hardware for all options. 2. SPECIFICATIONS Voltage Current Contact Rating 12 to 24 VDC +/- 10% 45 mA (peak) 1 Amp @ 30 VDC · Built-in Red and Green LED indication. Factory default = Red (Standby), Green (Triggered) · Red and Green LEDs can be controlled by sensor or externally · Adjustable detecting distance: 2 to 8 Inches (5 cm to 20 cm) · Adjustable Time Delay: 0.5 seconds to 20 seconds · Toggle function selection available · IP65 rating · IR lens to provide stable and reliable operation 4. OPERATION AT A GLANCE In a typical application, as you approach the CM-221, the LED will be red. When you wave your hand in front it will change the LED to green, and trigger its relay to change state and unlock your door, or trigger the door operator to open the door. The toggle feature can be used to trigger the door to remain in the unlocked position, until you wave your hand a second time to relock it. Contacts Common/ N.O./ N.C. Temperature Range 14F to 122F (-10 to 50 °C) Response Time 10ms Contruction Heavy duty extruded aluminum Finish Mounting Dimensions Anodized clear, dark bronze or stainless steel 4 x #14 wood screws or 1/4"20 S/S machine screws with anchors 37 -1/2" H x 5-7/8" W x 1-1/2" D (overall) NOTE: Do NOT use AC Voltage for this unit. Please see section 8 for power requirements Page 1 of 6 CM-7536VR Column Switch with Sensor INSTALLATION INSTRUCTIONS 5. CONFIGURING THE CM-7536VR Range of Detection and Output Duration Looking at the back of the CM-221 with the Mode pins located at the top, you will see two adjustment potentiometers. The one on the left can be turned clockwise to set the range of detection (2" to 8" / 5cm to 20cm), and the one on the right will set the duration of the output (0.5 to 20 seconds). If the output needs to be triggered and maintained in that state until triggered once more, then the Toggle feature can be used by turning the output duration adjustment potentiometer to the fully clockwise position. Remote LED Switching The CM-221 can also have its LED states controlled remotely. This is done by installing the supplied jumper from the parts bag onto the two pins on the back of the unit. Once installed the green and red LED's can be triggered to change by bringing either one low (to ground). The yellow wire controls the green LED, whereas, the white wire controls the red LED. They can be individually turned on or off, or they can be wired to a SPDT contact to turn red on and green off, or vice versa. MODE PINS: OPEN (Default position)= Internal mode where the LED colours will be controlled by the IR sensor. SHORTED = External mode where the LED colours will be controlled by Yellow and White wires. Adjustment for distance (2" to 8", 5 to 20 cm) Turn clockwise to increase range Adjustment for time delay (0.5 to 20 seconds) For Toggle. Turn clockwise to increase time delay -+ Page 2 of 6 CM-7536VR Column Switch with Sensor INSTALLATION INSTRUCTIONS 6. WIRING THE CM-7536VR The CM-7536 Touchless Column Switch connected to Door Operator -+ : 654 3 21 JS Tfotps Lvnrfs nvtu cf PGG, uif uxp rkot bsf opu tipsufe DBVUJPtOipA vBmem vcofvktofeekwdkpeovebmvmdukptpstmbufeboe tipvmecfkoekwkevbmmktpmbufeboe ubrfe. 120 WBD DY-RT13RpxfsTvrrm DY-RT13RpxfsTvrrm 12 ps 24 WED C- C+ ED- ED+ BD BD DY-US Usbothpsnfs 12, 16 ps 24 WBD OpsnbmmPrfoTxkudi OpsnbmmPrfoTxkudi DoorOperator DoorOperator # Dpmps Iwodulpo D1pmps SfeIwodulp1o2 up 24 WED 2 Cmbdl 0 WED (Ispvoe) 3 afmmpxIsffoNFEdpouspmmfecfyufsobmnpef. a4fmmpxXikuIfsffoSNFfEedNpFEou,sdppmmofuespcmmffeycufsfoybumfnsopbemfn. pef. 5 IsffSofeNFSEf,mdbpoAuOspmsmnfebmcmPfyruffosobmnpef. 6 CmvfSfmbASOfpmsbnAbDmmpnPnrfpoo : RvsrSmffmbASDfpmnbnAOpopsnbmmDmptfe RvsrmfSfmbAOpsnbmmDmptfe C. Page 3 of 6 CM-7536VR Column Switch with Sensor INSTALLATION INSTRUCTIONS CM-7536VR Touchless Column Switch connected to DPDT Relay -+ : 654 3 21 JS Tfotps Lvnrfs nvtu cf PGG, uif uxp rkot bsf opu tipsufe DBVUJPOA Bmm vovtfe dpoevdupst tipvmecfkoekwkevbmmktpmbufeboe ubrfe. OpsnbmmPrfo Txkudi DY-RT13RpxfsTvrrm 12 ps 24 WED C- C+ ED- ED+ BD BD 120 WBD DY-US Usbothpsnfs 12, 16 ps 24 WBD EsGpsnD dpoubdut Da-LSC Shmc 24W 12W W+ OD D OP W- OD D OP EsGpsnD dpoubdut # Drmrs Iwodulro 1 Sfe 12 up 24 WED 2 Cmbdl 0 WED (Ispvoe) 3 afmmpxIsffoNFEdpouspmmfecfyufsobmnpef. 4 XikufSfeNFE,dpouspmmfecfyufsobmnpef. 5 IsffoSfmbAOpsnbmmPrfo 6 Cmvf SfmbADpnnpo : RvsrmfSfmbAOpsnbmmDmptfe Page 4 of 6 CM-7536VR Column Switch with Sensor INSTALLATION INSTRUCTIONS 7. POWER The CM-7536VR Hands-Free ColumnTM switch is a VDC device only and will accept a range of VDC power from 12VDC to 24VDC (+/10%). Do not connect AC voltage to the CM-7536VR Hands-Free ColumnTM switch at any time. Note: A linear output VDC power supply is strongly recommended. If using power from other than Camden's CX-PS13 filtered regulated power supply, you must measure the provided power before applying power to the CM-7536VR Hands-Free ColumnTM switch. Voltages of more than 10% over the specified acceptable range or using a power supply with large amounts of AC voltage on it (unfiltered unregulated power such as a transformer and a rectifier) may damage the CM-7536VR Hands-Free ColumnTM switch and void the warranty. 5.950'' [151.13mm] 3.353'' [85.17mm] 1.743'' [44.28mm] 1.503'' [38.18mm] 36'' [914mm] Or 9'' [229mm] 20.500'' [520.70mm] 37 1/2'' [955mm] Or 10 5/8'' [270mm] Page 5 of 6 CM-7536VR Column Switch with Sensor INSTALLATION INSTRUCTIONS 8. INSTALLATION Code Requirements: If installed according to these instructions the CM-7536VR Column switch will meet the requirements of the California Building Code (Section 1117B.6, Date: 2009), and Section 3.8.3.3.17(b) of the Ontario Building Code. Installation Steps: 1. Remove the assembled unit from packaging. The unit must be disassembled to be installed. To do this, remove the two small Phillips screws holding the top cap in place. Remove the cap. Then, grasping the center (metal) actuation bar, pull vertically until the entire actuation bar is removed from the base unit. Set the actuation bar aside and protect from surface damage. CM-7536VR Hands-Free ColumnTM switch Drill a ØWa0Cv.2eu5tS0-ow''uHittcohlewire Wall CM-7536VR Hands-Free ColumnTM ElectrIinc-awl aBlol x Wall switch [64.727m1/m2''] Mounting without in-wall Mounting with in-wall electrical box electrical box 2. Determine the optimum height from the finished floor. See illustration (above) for common height. If utilizing an in-wall electrical box, center the touchless switch over the box for wire connection, while lining up the top edge with your mark. If mounting without an in-wall electrical box, drill a Ø 0.250''hole for wire connection. 3. Using a level, ensure the base unit is plumb and level, and mark the 4 mounting locations through the adjustable nylon inset screws onto the wall surface (if on drywall use a pencil, and if on concrete a narrow Sharpie or similar). 4. a) Drill the wall at the 4 marked locations and tap in the appropriate wall plugs. We supply both drywall and concrete anchors for the included #14 screws. 4. b) If mounting the Column Switch to an aluminum post or framing section, drill and tap 4 holes for 1/4"-20 Stainless Steel Machine screws (also provided). Note: Camden CM-42 and CM-48 series posts are available with pre-drilled and tapped holes preparation for ColumnTM switches. 9. SYSTEM INSPECTION: After the Installation and operational check of the system: 1. Place any applicable labels on the door (as per ANSI A156.10 or A156.19 guidelines). 2. Instruct the owner on door system operation and how to test it. This should be checked on a daily basis. 3. Strongly recommend to the owner that the complete entry be inspected twice a year as part of the service agreement. Opening New Doors to Call: 1.877.226.3369 / 905.366.3377 Innovation, Quality and Support! Visit: www.camdencontrols.com File: CM-7536VR_Manual.indd Rev.: May 11th, 2022 Part No.: 40-82B310 Page 6 of 6