Datasheet - AZM 161SK-12/12RKA-024

Solenoid interlock / AZM 161

Date: 10.06.2016

Product Description

The AZM 161SK-12/12RKA-024 is a solenoid interlock from Schmersal, designed for safety applications.

Key Features:

  • Thermoplastic enclosure
  • Double-insulated
  • Interlock with protection against incorrect locking
  • Dimensions: 130 mm x 90 mm x 30 mm
  • 6 Contacts
  • Long life
  • Large wiring compartment
  • Manual release capability
  • 4 cable entries M 16 x 1.5

Minor differences between the printed image and the original product may exist.

Ordering Details

Product type descriptionArticle numberEAN codeeCl@ss
AZM 161SK-12/12RKA-024101166285403066121397227-27-26-03

Approval

The product has the following approvals:

  • BG
  • CULUS USA/CAN
  • EAC
  • CCC

Classification

StandardsB10d Opener (NC)Mission timeNotice
EN ISO 13849-12,000,00020 YearsB10d, MTTF

Global Properties

PropertyValue
Product nameAZM 161
StandardsEN 60947-5-1, BG-GS-ET-19
Compliance with DirectivesYes
Number of actuating directions3 piece
Active principleElectromechanical
Duty cycleMagnet 100%
MaterialsPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Material of the housingsSilver
Material of the contactsNone
Housing coating460 g

Mechanical Data

ParameterValue
Actuating play in direction of actuation5.5 mm
Design of electrical connectionScrew connection
Cable section1 x 0.25 mm² to 1 x 1.5 mm²
Mechanical life> 1,000,000 operations
NoticeAll indications about the cable section are including the conductor ferrules.
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching force30 N
Positive break force20 N
Positive break travel10 mm
Clamping force F2000 N
Max. Actuating speed2 m/s
Actuating frequencymax. 1000/h

Ambient Conditions

ParameterValue
Min. environmental temperature-25 °C
Max. environmental temperature+60 °C
Protection classIP67 to IEC/EN 60529

Electrical Data

ParameterValue
Design of control elementNormally open contact (NO), Opener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts2 piece
Number of safety contacts4 piece
Power to unlockNo
Power to lockYes
Rated control voltage Us24 VAC/DC
Power consumptionmax. 10 W
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Thermal test current Ithe6 A
Utilisation categoryAC-15: 230 V/4A, DC-13: 24 V / 2.5 A
Required rated short-circuit current1000 A
Max. fuse rating6 A gG D-fuse To DIN EN 60269-1

ATEX

ParameterValue
Explosion protection categories for gasesNone
Explosion protected category for dustsNone

Miscellaneous Data

Applications

Suitable for:

  • Sliding safety guard
  • Removable guard
  • Hinged safety guard

Dimensions

DimensionValue
Width of sensor130 mm
Height of sensor90 mm
Length of sensor30 mm

Manual Release

The manual release is used for maintenance and installation. It can be operated using an M5 triangular key, which is available as an accessory.

Diagrams and Electrical Connections

Electrical Diagram

The diagram shows the terminal layout and internal connections. Key terminals include 13, 14, 21, 22, 41, 42, 51, 52, 63, 64, 71, 72, A1, A2. Symbols indicate contact types: Normally-open contact, Normally-closed contact, and positive break NC contact status (active/no active).

Electrical connection diagram with terminal numbering.

Switch Travel Diagram

The switch travel diagram illustrates contact states (closed/open) relative to the actuator position, including setting range, break point, and adjustable ranges for NO and NC contacts.

Notes on switch travel diagram symbols.

Ordering Suffix and Code

The applicable ordering suffix is added at the end of the part number. The general ordering code structure is: AZM 161 (1)-(2)(3)K(4)-(5)-(6)(7)

Suffix Options:

  • (1) Connection Type: SK (Screw connection), CC (Cage clamps), ST (male connector M12, 8- and 4-poles for 24 VAC/DC)
  • (2) Contact Configuration: 12/12 (2 NO / 4 NC), 12/11 (2 NO / 3 NC - Plug-in), 11/12 (2 NO / 3 NC - Plug-in)
  • (3) Latching Force: without (5 N), R (30 N)
  • (4) Function: without (Power to unlock), A (Power to lock)
  • (5) Manual Release/Emergency Exit: without (Manual release lateral), ED (Manual release cover-side), EU (Manual release rear), T (Emergency exit lateral), TD (Emergency exit cover-side), TU (Emergency exit rear), N (Emergency release)
  • (6) Rated Control Voltage Us: 024 (24 VAC/DC), 110/230 (110/230 VAC)
  • (7) Additional Feature: G (with LED - only for 24 VAC/DC)

Example: AZM 161SK-12/12RKA-024G

Documents

The following documents are available:

  • Operating instructions and Declaration of conformity (sv) - Code: mrl_azm161_sv
  • Operating instructions and Declaration of conformity (es) - Code: mrl_azm161_es
  • Operating instructions and Declaration of conformity (de) - Code: mrl_azm161_de
  • Operating instructions and Declaration of conformity (pt) - Code: mrl_azm161_pt
  • Operating instructions and Declaration of conformity (en) - Code: mrl_azm161_en
  • Operating instructions and Declaration of conformity (pl) - Code: mrl_azm161_pl
  • Operating instructions and Declaration of conformity (fr) - Code: mrl_azm161_fr
  • Operating instructions and Declaration of conformity (cs) - Code: mrl_azm161_cs
  • Operating instructions and Declaration of conformity (jp) - Code: mrl_azm161_jp
  • Operating instructions and Declaration of conformity (it) - Code: mrl_azm161_it
  • Operating instructions and Declaration of conformity (nl) - Code: mrl_azm161_nl
  • BG-test certificate (de) - Code: z_m16p01
  • BG-test certificate (en) - Code: z_m16p02
  • CCC certification (en) - Code: q_371p02
  • CCC certification (cn) - Code: q_371p03
  • EAC certification (ru) - Code: q_6040p17_ru
  • Notice (de, en) - Code: s_161p01

Dimensional Drawings

Detailed drawings showing the physical dimensions of the basic component are provided.

Dimensional drawing (basic component) showing front, side, and top views with key dimensions labeled.

Dimensional drawing (basic component) showing alternative views with key dimensions labeled.

Operating Principle

The diagrams illustrate the operating principle of the solenoid interlock, showing how the actuator engages with the device to ensure safety.

Diagram illustrating the insertion of the actuator into the interlock.

Diagram showing the actuator in the locked position.

System Components: Actuators and Door-Handle Systems

Various actuators and a door-handle system are available for use with the AZM 161 series:

Actuators

  • 101145117 - AZM 161-B1
  • 101144416 - AZM 161-B1E
  • 101171859 - AZM 161-B1ES
  • 101175431 - AZM 161-B1F
  • 101171125 - AZM 161-B1S
  • 101173089 - AZM 161-B1-2053 WITH BALL LATCH
  • 101164100 - AZM 161-B1-1747 WITH MAGNETIC LATCH
  • 101178199 - AZM 161-B1-2024
  • 101176642 - AZM 161-B1-2177 WITH CENTERING GUIDE
  • 101174113 - AZM 161-B6-2177 WITH CENTERING GUIDE (For very small actuating radii)
  • 101170375 - AZM 161-B6S
  • 101144420 - AZM 161-B6 (For very small actuating radii)

Door-Handle System

  • AZM 161-STS30 (Latching handle, suitable for all types of guard)

Accessories

The following accessories are available:

  • 101100887 - TRIANGULAR KEY TK-M5 (For manual release using M5 triangular key, available as accessory; for maintenance, installation, etc.)
  • 101149213 - Mounting set MS AZM 161 R/P
  • 101150376 - Mounting set MS AZM 161 P

PDF preview unavailable. Download the PDF instead.

48 KASBASE - AspPDF - Persits Software KASBASE by

Related Documents

PreviewSchmersal AZM 161CC-12/12KA-024 Solenoid Interlock: Operation and Installation Guide
Comprehensive guide for the Schmersal AZM 161CC-12/12KA-024 solenoid interlock, covering operation, installation, technical data, safety features, and disposal. Includes ordering codes and contact options.
PreviewSchmersal AZM 161 Solenoid Interlock: Operation and Mounting Instructions
Comprehensive guide to the Schmersal AZM 161 Solenoid Interlock, covering operation, mounting, electrical connection, and safety classifications. Essential for authorized personnel.
PreviewSchmersal AZM 161 Solenoid Interlock Operation and Mounting Instructions
Comprehensive guide for the operation and mounting of the Schmersal AZM 161 Solenoid Interlock, covering function, product description, technical data, electrical connections, and safety classifications.
PreviewSolenoid Interlock AZM 161SK-12/12RKTD/EU-110/230 Installation and Operating Instructions
Comprehensive installation and operating instructions for the Schmersal Solenoid Interlock AZM 161SK-12/12RKTD/EU-110/230. Covers function, safety, product description, mounting, electrical connection, setup, maintenance, disassembly, and disposal.
PreviewSchmersal AZM 161CC-12/12KA-024: Operating and Mounting Instructions
Comprehensive guide for the mounting, setup, and safe operation of the Schmersal AZM 161CC-12/12KA-024 safety interlock switch. Covers product description, technical data, electrical connections, and safety classifications.
PreviewSchmersal AZM 161CC Solenoid Interlock: Installation and Operation Manual
Comprehensive guide for the Schmersal AZM 161CC Solenoid Interlock, covering installation, operation, technical data, and safety instructions. Learn about product features, ordering codes, and electrical connections for secure machine guarding.
PreviewSchmersal AZM 161SK Solenoid Interlock: Installation and Operation Manual
Comprehensive instructions for the installation, operation, and maintenance of the Schmersal AZM 161SK series solenoid interlock. Covers product description, ordering codes, technical data, safety classifications, electrical connections, mounting, and disassembly.
PreviewSchmersal AZM 150 Safety Interlock Switch Certificate of Conformity
Certificate of conformity for the Schmersal AZM 150 Safety Interlock Switch with Solenoid Interlock, detailing its compliance with EN standards and technical specifications.