KitchenAid Electric Double Wall Oven Dimension Guide
Product Models: KOED330P, KOED530PAppliance Dimensions (30" Electric Double Wall Oven)
Label | Description | Units (in) | Units (cm) |
---|
A | Depth Closed Excluding Handle (Flush Install) | 241/2 | 62.2 |
B | Depth Closed Including Handle | 2615/16 | 68.4 |
C | Depth to Back of Console (Standard Depth) | 231/16 | 58.6 |
D | Depth with Door Open 90° | 463/16 | 117.2 |
E | Maximum Height (Including Console) | 525/8 | 133.7 |
E | Minimum Height (Including Console) | 507/8 | 129.2 |
F | Width | 293/4 | 75.6 |
G | Maximum Height (Not Including Console) | 501/2 | 128.3 |
G | Minimum Height (Not Including Console) | 483/4 | 123.8 |
Diagrams illustrating angled and side views of the appliance are provided.
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Owner's Manual before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
- To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
- Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance with oven.
- Recessed installation area must provide complete enclosure around the recessed portion of the oven.
- Grounded electrical supply is required. See "Electrical Requirements" section.
- Electrical supply junction box should be located 3" (7.6 cm) maximum below the support surface when the oven is installed in a wall cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the right rear or left rear corner of the support surface to pass the appliance cable through to the junction box.
- NOTE: For undercounter installation, it is recommended that the junction box be located in the adjacent right or left cabinet. If you are installing the junction box on rear wall behind oven, it is recommended that the junction box be recessed and located in the upper center of the cabinet.
- Oven support surface must be solid, level and flush with bottom of cabinet cutout.
- Floor must be able to support a single oven weight of 330 lbs (150 kg) for 30" (76.2 cm) models.
- IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Cabinet Dimensions - Standard Installation (30" Double Ovens)
Label | Description | Units (in) | Units (cm) |
---|
A | Maximum overall height | 513/4 | 131.5 |
B | Maximum recessed width | 287/16 | 72.2 |
C | Recessed height | 4813/16 | 124.0 |
D | Maximum recessed depth | 231/4 | 59.1 |
E | Overall width | 293/4 | 75.6 |
F | From back of control panel to start of strain relief | 12 | 30.5 |
G | Flexible conduit length | 66 | 167.6 |
Diagrams illustrating the standard installation of a double oven in a cabinet are provided.
Cabinet Dimensions - Flush Installation (30" Double Ovens)
This is an alternate option to install your product in the cabinet and obtain a flush look. For standard installation, refer to section "Product Dimensions - Double Ovens, Standard Installation."
- A minimum cutout depth of 253/8" (64.4 cm) is required.
- Top and bottom gaps will be 1/8" (0.3 cm) above and below the product. Top and bottom gaps are not required for installation. Exposed areas of the cabinet should be finished to match.
Label | Description | Units (in) | Units (cm) |
---|
A | Top cleat* | 3/4 | 1.9 |
B | Minimum flush inset cutout width | 301/4 | 76.8 |
C | Minimum opening width | 287/8 | 73.3 |
D | Minimum flush inset cutout height | 52 | 132.1 |
E | Recommended cutout height | 511/4 | 130.1 |
F | Side cleat* | 11/16 | 1.7 |
G | Recommended with foot: 1/4" (0.6 cm). Allowable without foot: 15/16" to 1 1/8" (2.2 cm to 2.9 cm) | | |
H | Recommended junction box location | | |
I | Bottom of cutout to floor | 45/8" to 32" (11.7 cm-81.3 cm) | |
J | Minimum cutout depth | 25 | 63.5 |
*Cleats and spacers must be recessed 13/8" (3.5 cm) from the front of the cabinet.
Diagrams illustrating front, side, and top views for flush installation are provided.
Electrical Requirements
WARNING
- Electrical Shock Hazard
- Plug into a grounded 3 prong outlet.
- Do not remove ground prong.
- Do not use an adapter.
- Do not use an extension cord.
- Failure to follow these instructions can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and the wire gauge are in accordance with local codes.
Check with a qualified electrical installer if you are not sure the oven is properly grounded.
This oven must be connected to a grounded metal, permanent wiring system.
Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
- National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471
- CSA International, 8501 East Pleasant Valley Road, Cleveland, OH 44131-5575
Electrical Connection
To properly install your oven, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
- Oven must be connected to the proper electrical voltage and frequency as specified on the model/serial/rating plate. The model/serial/rating plate is located under the control panel on single ovens and under the control panel on the upper oven cavity on double ovens. See the following illustration.
Diagram showing the location of the model/serial/rating plate is provided.
- Models rated from 7.3 to 9.6 kW at 240 V (5.4 to 7.4 kW at 208 V) require a separate 40 A circuit. Models rated at 4.8 kW and below at 240 V (3.6 kW and below at 208 V) require a separate 20 A circuit.
- A circuit breaker is recommended.
- Connect directly to the fused disconnect (or circuit breaker box) through flexible, armored or nonmetallic sheathed, copper cable (with grounding wire). See the "Make Electrical Connection" section in the Owner's Manual.
- Flexible conduit from the oven should be connected directly to the junction box.
- Fuse both sides of the line.
- Do not cut the conduit. The length of conduit provided is for serviceability of the oven.
- A UL listed or CSA-approved conduit connector must be provided.
- If the house has aluminum wiring, follow the procedure below: Connect the aluminum wiring using special connectors and/or tools designed and UL listed for joining copper to aluminum. Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry-accepted wiring practices.
Models: KOED530PSS Double Wall Oven 30 Inch With Air Fry Mode, KOED530PSS, Double Wall Oven 30 Inch With Air Fry Mode, Oven 30 Inch With Air Fry Mode, Air Fry Mode, Fry Mode