Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers - Cisco
Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers First Published: 2020-03-02 Last Modified: 2020-09-22 Document Revision History The following table shows the changes made to this document: Date Change Summary March 2020 First version of the document. September 2020 Updated Upgrading Ethernet PHY (Fiber) section with firmware version 3.1.96. Audience This publication is for performing upgrades in the field on the hardware programmable firmware of the following Cisco Catalyst 9800 Series Wireless Controllers. · Cisco Catalyst 9800-80 Wireless Controller · Cisco Catalyst 9800-40 Wireless Controller · Cisco Catalyst 9800-L Wireless Controller Conventions Text Type User input Document titles System output CLI commands Indication Text the user should enter exactly as shown or keys a user should press appear in this font. Document titles appear in this font. Terminal sessions and information that the system displays appear in this font. CLI command keywords appear in this font. Variables in a CLI command appear in this font. Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 1 Conventions Text Type [] {x | y | z} [x | y | z] String <> [] ! # Indication Elements in square brackets are optional. Required alternative keywords are grouped in braces and separated by vertical bars. Optional alternative keywords are grouped in brackets and separated by vertical bars. A nonquoted set of characters. Do not use quotation marks around the string or the string will include the quotation marks. Nonprinting characters such as passwords are in angle brackets. Default responses to system prompts are in square brackets. An exclamation point (!) or a pound sign (#) at the beginning of a line of code indicates a comment line. Note Means reader take note. Notes contain helpful suggestions or references to material not covered in the document. Tip Means the following information will help you solve a problem. The tips information might not be troubleshooting or even an action, but could be useful information, similar to a Timesaver. Caution Means reader be careful. In this situation, you might perform an action that could result in equipment damage or loss of data. Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. SAVE THESE INSTRUCTIONS Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 2 Related Documentation Related Documentation See the following documentation for more information about the Cisco Catalyst 9800 Series Wireless Controllers: · Release Notes for Cisco Catalyst 9800 Series Wireless Controller · Cisco Catalyst 9800 Series Wireless Controller Software Configuration Guide · Cisco Catalyst 9800 Series Wireless Controller Command Reference · Cisco Wireless Solutions Software Compatibility Matrix Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, using the Cisco Bug Search Tool (BST), submitting a service request, and gathering additional information, see What's New in Cisco Product Documentation. To receive new and revised Cisco technical content directly to your desktop, you can subscribe to the What's New in Cisco Product Documentation RSS feed. RSS feeds are a free service. Upgrading Field Programmable Hardware Devices Overview This document describes how to perform upgrades in the field on the hardware programmable firmware of the following Cisco Catalyst 9800 Series Wireless Controllers. · Cisco Catalyst 9800-80 Wireless Controller · Cisco Catalyst 9800-40 Wireless Controller · Cisco Catalyst 9800-L Wireless Controller If the controller contains an old version of the hardware programmable firmware, then that hardware programmable firmware may need to be upgraded. To do this upgrade, a hardware programmable package is released to the customers. Generally, an upgrade is only necessary in cases where a system message indicates one of the field programmable devices needs an upgrade or a Cisco technical support representative suggests an upgrade. Note During hw-programmables upgrade, the controller may reboot several times and it is not advisable to power cycle the device during this period as it may lead to device failure. Remember that a typical upgrade process would take about 30 minutes to complete the cycle. Important · Schedule a planned maintenance window before starting the upgrade activity. · DO NOT disturb the device or power cycle the device till the upgrade activity is complete. Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 3 Upgrading Field Programmables for Cisco Catalyst 9800-L Wireless Controller ROMMON Images A ROMMON image is a software package used by ROM Monitor (ROMMON) software on a controller. The software package is separate from the consolidated package normally used to boot the controller. An independent ROMMON image (software package) may occasionally be released and the controller can be upgraded with the new ROMMON software. Ethernet PHY Images This firmware (software upgrade) is for Ethernet PHY and MAC images of the Cisco Catalyst 9800-L Wireless Controllers. Upgrading Field Programmables for Cisco Catalyst 9800-L Wireless Controller This section explains field programmable installation procedure for Cisco Catalyst 9800-L Wireless Controller. Upgrading ROMMON for Cisco Catalyst 9800-L Wireless Controllers Note If your setup is in High Availability mode, break the High Availability and follow the below steps given below on both the controllers. After a successful upgrade, re-enable the High Availability. Note During ROMMON upgrade, the controller may reboot several times and it is not advisable to power cycle the device during this period as it may lead to device failure. Remember that a typical upgrade process would take about 30 minutes to complete the cycle. Before you begin Verify the current ROMMON version using the following commands: · Standalone Setup Device# show rom-monitor chassis active r0 ========================================================== System Bootstrap, Version 16.12(1r), RELEASE SOFTWARE Copyright (c) 1994-2019 by cisco Systems, Inc. · High-Availability Setup Run the following commands on the active controller. Verify the current ROMMON version for Active controller: Device# show rom-monitor chassis active r0 ========================================================== System Bootstrap, Version 16.12(1r), RELEASE SOFTWARE Copyright (c) 1994-2019 by Cisco Systems, Inc. Verify the current ROMMON version for Standby controller: Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 4 Upgrading ROMMON for Cisco Catalyst 9800-L Wireless Controllers Device# show rom-monitor chassis standby r0 ========================================================== System Bootstrap, Version 16.12(1r), RELEASE SOFTWARE Copyright (c) 1994-2019 by cisco Systems, Inc. If the ROMMON version is earlier than 16.12(3r) for the standalone, active, or standby controller, use the procedure given below to upgrade the ROMMON: Procedure Step 1 Step 2 Go to the software download page: https://software.cisco.com/download/home/286321399/type · Select IOS XE ROMMON Software. · Go to the release number. · Click on the download button for the C9800-L-rommon.1612-3r.pkg. Copy the ROMMON image to bootflash, using TFTP or USB. · TFTP: copy tftp://ip address of TFTP server/file path/C9800-L-rommon.1612-3r.pkg bootflash: · USB: copy usb0: C9800-L-rommon.1612-3r.pkg bootflash: After the system confirms that the copy operation is successful (sample output given below), proceed to the next step. Device# $copy tftp://9.1.0.101/PATH/FILENAME bootflash: Destination filename [C9800-L-rommon.1612-3r.pkg]? Accessing tftp://9.1.0.101/c9800/C9800-L-rommon.1612-3r.pkg... Loading c9800/C9800-L-rommon.1612-3r.pkg from 9.1.0.101 (via Vlan44): !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! [OK - 7805964 bytes] 7805964 bytes copied in 6.697 secs (1165591 bytes/sec) Step 3 Initiate the upgrade using the command given below and follow the instructions from the tool. Device# upgrade rom-monitor filename bootflash:C9800-L-rommon.1612-3r.pkg chassis active r0 Verifying the code signature of the ROMMON package... Chassis model C9800-L-F-K9 has a single rom-monitor. Upgrade rom-monitor Target copying rom-monitor image file Secure update of the ROMMON image will occur after a reload. 8388608+0 records in Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 5 Upgrading ROMMON for Cisco Catalyst 9800-L Wireless Controllers 8388608+0 records out Copying ROMMON environment 8388608+0 records in 131072 bytes (131 kB, 128 KiB) copied, 1.47571 s, 88.8 kB/s ROMMON upgrade complete. To make the new ROMMON permanent, you must restart the RP. Step 4 Reboot the controller by entering this command: Device# reload Reload command is being issued on Active unit, this will reload the whole stack Proceed with reload? [confirm] *Nov 27 11:06:31.648: %SYS-5-RELOAD: Reload requested by console. Reload Reason: Reload Command. Chassis 1 reloading, reason - Reload command Nov 27 11:06:39.735: %PMAN-5-EXINov 27 11:06:39.755: %PMAN-5-EXITACTION: F0/0: pvp: Process manager is exiting: Nov 27 11:06:40.856: %PMAN-5-EX Initializing Hardware ... System Bootstrap, Version 16.12(1r), RELEASE SOFTWARE Copyright (c) 1994-2019 by cisco Systems, Inc. Current image running: Boot ROM1 Last reset cause: LocalSoft The values of MSR 0x198h = 00001400 and MSR 0x199h = 00001400 for C9800-L C9800-L-X-K9 platform with 16777216 Kbytes of main memory Successfully initiated a secure capsule update. The system will be reset multiple times for completing the capsule update. Please wait till you get the promp Initializing Hardware ... Platform Name: Grangeville-NS Current Version: GRNV-NS.05.22.12.0008 Update Version: GRNV-NS.05.22.12.0008 Updating Block at FEFF0000h 0% Updating Block at FEFF1000h 0% Updating Block at FFFFE000h 99% Updating Block at FFFFF000h 100% Initializing Hardware ... System Bootstrap, Version 16.12(3r), RELEASE SOFTWARE Copyright (c) 1994-2019 by Cisco Systems, Inc. Current image running: Boot ROM1 Last reset cause: LocalSoft The values of MSR 0x198h = 00001400 and MSR 0x199h = 00001400 for C9800-L C9800-L-X-K9 platform with 16777216 Kbytes of main memory Secure capsule update was successful Capsule Processed : 11/27/2019 11:12 UTC Capsule Status : Success Flash upgrade reset 1 in progress Initializing Hardware ... Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 6 Upgrading ROMMON for Cisco Catalyst 9800-L Wireless Controllers System Bootstrap, Version 16.12(3r), RELEASE SOFTWARE Copyright (c) 1994-2019 by Cisco Systems, Inc. Current image running: *Upgrade in progress* Boot ROM0 Last reset cause: BootRomUpgrade The values of MSR 0x198h = 00001400 and MSR 0x199h = 00001400 for C9800-L C9800-L-X-K9 platform with 16777216 Kbytes of main memory File size is 0x38fed6b2 Located C9800-L-universalk9_wlc.16.12.02prd5.SPA.bin Image size 956225202 inode num 21, bks cnt 233454 blk size 8*512 ########################################################################################################## Boot image size = 956225202 (0x38fed6b2) bytes ROM:RSA Self Test Passed ROM:Sha512 Self Test Passed Package header rev 3 structure detected Calculating SHA-1 hash...done validate_package_cs: SHA-1 hash: calculated ce3982a2:f0737625:72fcbb02:93ed3683:b7fe0a2e expected ce3982a2:f0737625:72fcbb02:93ed3683:b7fe0a2e Validating main package signatures RSA Signed RELEASE Image Signature Verification Successful. Validating subpackage signatures Image validated Both links down, not waiting for other chassis Chassis number is 1 Nov 27 11:16:23.371: %PMAN-3-PROC_EMPTY_EXEC_FILE: R0/0: pvp: Empty executable used for process dpman Nov 27 11:16:34.902: %PMAN-3-PROC_EMPTY_EXEC_FILE: R0/0: pvp: Empty executable used for process bt_logger Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Commercial Computer Software - Restricted Rights clause at FAR sec. 52.227-19 and subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS sec. 252.227-7013. Cisco Systems, Inc. 170 West Tasman Drive San Jose, California 95134-1706 Cisco IOS Software [Gibraltar], C9800 Software (C9800_IOSXE-K9), Version 16.12.2prd5, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2019 by Cisco Systems, Inc. Compiled Sat 09-Nov-19 03:06 by mcpre This software version supports only Smart Licensing as the software licensing mechanism. PLEASE READ THE FOLLOWING TERMS CAREFULLY. INSTALLING THE LICENSE OR LICENSE KEY PROVIDED FOR ANY CISCO SOFTWARE PRODUCT, PRODUCT FEATURE, AND/OR SUBSEQUENTLY PROVIDED SOFTWARE FEATURES (COLLECTIVELY, THE "SOFTWARE"), AND/OR USING SUCH SOFTWARE CONSTITUTES YOUR FULL ACCEPTANCE OF THE FOLLOWING TERMS. YOU MUST NOT PROCEED FURTHER IF YOU ARE NOT WILLING TO BE BOUND BY ALL THE TERMS SET FORTH HEREIN. Your use of the Software is subject to the Cisco End User License Agreement (EULA) and any relevant supplemental terms (SEULA) found at http://www.cisco.com/c/en/us/about/legal/cloud-and-software/software-terms.html. Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 7 Upgrading Ethernet PHY (Fiber) You hereby acknowledge and agree that certain Software and/or features are licensed for a particular term, that the license to such Software and/or features is valid only for the applicable term and that such Software and/or features may be shut down or otherwise terminated by Cisco after expiration of the applicable license term (e.g., 90-day trial period). Cisco reserves the right to terminate any such Software feature electronically or by any other means available. While Cisco may provide alerts, it is your sole responsibility to monitor your usage of any such term Software feature to ensure that your systems and networks are prepared for a shutdown of the Software feature. FIPS: Flash Key Check : Key Not Found, FIPS Mode Not Enabled All TCP AO KDF Tests Pass Cisco C9800-L-F-K9 (C9800-L) processor (revision C9800-L) with 1711451K/6147K bytes of memory. Processor board ID FCL234400CV 1 Virtual Ethernet interface 4 2.5 Gigabit Ethernet interfaces 2 Ten Gigabit Ethernet interfaces 32768K bytes of non-volatile configuration memory. 16777216K bytes of physical memory. 26251263K bytes of eUSB flash at bootflash:. 0K bytes of WebUI ODM Files at webui:. Base Ethernet MAC Address : F4:BD:9E:56:5F:E0 Installation mode is BUNDLE Press RETURN to get started! *Nov 27 11:17:18.273: %SMART_LIC-6-EXPORT_CONTROLLED: Usage of export controlled features is not allowed Adding registry invocations for the WLC platform *Nov 27 11:17:19.690: %SMART_LIC-6-AGENT_READY: Smart Agent for Licensing is initialized *Nov 27 11:17:19.690: %SMART_LIC-6-AGENT_ENABLED: Smart Agent for Licensing is enabled *Nov 27 11:18:00.374: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet0/1/1, changed state to up *Nov 27 11:18:07.446: %SMART_LIC-6-EXPORT_CONTROLLED: Usage of export controlled features is not allowed *Nov 27 11:18:07.446: %CALL_HOME-6-CALL_HOME_ENABLED: Call-home is enabled by Smart Agent for Licensing. Step 5 Verify the update on both active and standby controllers by entering this command: Device# show rom-monitor chassis active r0 ========================================================== System Bootstrap, Version 16.12(3r), RELEASE SOFTWARE Copyright (c) 1994-2019 by Cisco Systems, Inc. Upgrading Ethernet PHY (Fiber) Before you begin This Ethernet PHY upgrade procedure applies only to Fiber SKU (C9800-L-F-K9) model of the Cisco Catalyst 9800-L Wireless Controller. Use the following command identify the models. Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 8 Upgrading Ethernet PHY (Fiber) Device# show inventory NAME: "Chassis 2", DESCR: "Cisco C9800-L-F-K9 Chassis" PID: C9800-L-F-K9 , VID: 01 , SN: FCW2328H00A Verify the current Ethernet PHY version on the standalone, active, or standby controllers using the following show commands: · Standalone Setup Device# show platform hardware chassis active qfp datapath pmd ifdev | i FW ========================================================== FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW Version : 0x80000757 : 9.1.0 ID: 43503 vers: 1275 : 0x80000757 : 9.1.0 ID: 43503 vers: 1275 : 0x80000756 : 9.1.0 ID: 43503 vers: 1275 : 0x80000756 : 9.1.0 ID: 43503 vers: 1275 : 3.1.78 : 3.1.78 · High-Availability Setup Run the following commands only on the active controller. Verify the current Ethernet PHY version for Active controller. Device# show platform hardware chassis active qfp datapath pmd ifdev | i FW ========================================================== FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW Version : 0x80000757 : 9.1.0 ID: 43503 vers: 1275 : 0x80000757 : 9.1.0 ID: 43503 vers: 1275 : 0x80000756 : 9.1.0 ID: 43503 vers: 1275 : 0x80000756 : 9.1.0 ID: 43503 vers: 1275 : 3.1.78 : 3.1.78 Verify the current Ethernet PHY version for Standby controller. Device# show platform hardware chassis standby qfp datapath pmd ifdev | i FW ========================================================== FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW Version : 0x80000757 : 9.1.0 ID: 43503 vers: 1275 : 0x80000757 : 9.1.0 ID: 43503 vers: 1275 : 0x80000756 : 9.1.0 ID: 43503 vers: 1275 : 0x80000756 : 9.1.0 ID: 43503 vers: 1275 : 3.1.78 : 3.1.78 Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 9 Upgrading Ethernet PHY (Fiber) If any of the Ethernet PHY firmware (FW or MDIO) versions is earlier than the firmware version given in the show command output for the standalone, active, or standby controller, use the procedure given below to upgrade the Ethernet PHY firmware: Procedure Step 1 Step 2 Go to the software download page: https://software.cisco.com/download/home/286321399/type · Select IOS Hardware Programmable Devices. · Go to the release number. · Click on the download button for the C9800-L-hw-programmables.17.03.01.SPA.pkg Copy the Ethernet PHY image to bootflash: using TFTP or USB. · TFTP: copy tftp://ip address of TFTP server/file path/ C9800-L-hw-programmables.17.03.01.SPA.pkg bootflash: · USB: copy usb0: C9800-L-hw-programmables.17.03.01.SPA.pkg bootflash: After the system confirms that the copy operation is successful (sample output given below), proceed to the next step. Device# $copy tftp://9.1.0.101/PATH/FILENAME bootflash: Destination filename [C9800-L-hw-programmables.17.03.01.SPA.pkg ]? Accessing tftp://9.1.0.101/c9800/C9800-L-hw-programmables.17.03.01.SPA.pkg Loading c9800/ C9800-L-hw-programmables.17.03.01.SPA.pkg from 9.1.0.101 (via Vlan44): !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! [OK - 2106376 bytes] Step 3 Initiate the upgrade using the command given below and follow the instructions from the tool. Device# upgrade hw-programmable phy filename bootflash: C9800-L-hw-programmables.17.03.01.SPA.pkg Update PHY firmware on C9800-L platform. Upgrade Ver for AQR412 is 9.1.2.1385 Upgrade Ver for AQC100 is 3.1.106 PHY upgrade pending for Reboot. Please reboot to upgrade the firmware. Step 4 Reboot the controller by entering this command: Device# reload Reload command is being issued on Active unit, this will reload the whole stack Proceed with reload? [confirm] *Mar 6 04:25:52.650: %SYS-5-RELOAD: Reload requested by new on console. Reload Reason: Reload Command. Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 10 Upgrading Ethernet PHY (Fiber) Step 5 Step 6 Validating subpackage signatures Image validated Tue Mar 6 04:28:37 UTC 2018 Calling Aquantia Firmware upgrade process Tue Mar 6 04:29:34 UTC 2018 file: /bootflash/aq_phy_upgrade_info deleted Tue Mar 6 04:29:34 UTC 2018 Updating Phy firmware from pakage file = /bootflash/C9800-L-hw-programmables.17.03.01.SPA.pkg Tue Mar 6 04:29:35 UTC 2018 Bay0: Firmware: /tmp/hwprg_upgrade_pub/hwprog/RP/KATAR/PHY/AQR412/upgrade_phy.cld Tue Mar 6 04:29:35 UTC 2018 Bay0: Firmware Version: 9.1.2.1385 Tue Mar 6 04:29:35 UTC 2018 Bay1: Firmware: /tmp/hwprg_upgrade_pub/hwprog/RP/KATAR/PHY/AQC100/upgrade_phy.clx Tue Mar 6 04:29:35 UTC 2018 Bay1: Firmware Version: 3.1.106 Tue Mar 6 04:29:35 UTC 2018 /bootflash/C9800-L-hw-programmables.17.03.01.SPA.pkg is code signed Tue Mar 6 04:29:35 UTC 2018 ################################################################## Tue Mar 6 04:29:35 UTC 2018 # Please make sure POWER SUPPLY is always ON during this period. # Tue Mar 6 04:29:35 UTC 2018 # Loss of POWER will completely kill this unit and make it # Tue Mar 6 04:29:36 UTC 2018 # unrecoverable # Tue Mar 6 04:29:36 UTC 2018 ################################################################## Tue Mar 6 04:29:36 UTC 2018 ################################################################# Tue Mar 6 04:29:36 UTC 2018 Aquantia Bay-0 upgrade firmware: /tmp/hwprg_upgrade_pub/hwprog/RP/KATAR/PHY/AQR412/upgrade_phy.cld found Tue Mar 6 04:29:36 UTC 2018 Aquantia firmware upgrade for Bay-0 started. Please wait. Tue Mar 6 04:29:36 UTC 2018 ################################################################# Tue Mar 6 04:29:37 UTC 2018 Current version of Bay-0 firmware: 9.1.2.1385 upgrade version: 9.1.2.1385 Tue Mar 6 04:31:38 UTC 2018 Aquantia firmware upgrade succeeded for Bay-0 ################################################################## ################################################################# Tue Mar 6 04:31:38 UTC 2018 Aquantia Bay-1 upgrade firmware: /tmp/hwprg_upgrade_pub/hwprog/RP/KATAR/PHY/AQC100/upgrade_phy.clx found Tue Mar 6 04:31:38 UTC 2018 Aquantia firmware upgrade for Bay-1 port-1 started ################################################################# Tue Mar 6 04:31:39 UTC 2018 Current version of Bay-1 port-1 firmware: 3.1.96 upgrade version: 3.1.106 Tue Mar 6 04:31:59 UTC 2018 Aquantia firmware upgrade succeeded for Bay-1 port-1 Tue Mar 6 04:31:59 UTC 2018 ################################################################## Tue Mar 6 04:31:59 UTC 2018 ################################################################# Tue Mar 6 04:31:59 UTC 2018 Aquantia firmware upgrade for Bay-1 port-2 started Tue Mar 6 04:31:59 UTC 2018 ################################################################# Tue Mar 6 04:31:59 UTC 2018 Current version of Bay-1 port-1 firmware: 3.1.96 upgrade version: 3.1.106 Tue Mar 6 04:32:18 UTC 2018 Aquantia firmware upgrade succeeded for Bay-1 port-2 Tue Mar 6 04:32:18 UTC 2018 ################################################################## Tue Mar 6 04:32:18 UTC 2018 Aquantia firmware upgrade completed successfully!!! Tue Mar 6 04:32:18 UTC 2018 Rebooting box Initializing Hardware ... After the upgrade is complete, device power cycles automatically, and IOS prompt is displayed. Verify the update on the controller by entering this command: Device# show platform hardware chassis active qfp datapath pmd ifdev | i FW Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 11 Upgrading Ethernet PHY (Copper) ========================================================== FW Version : 0x80000757 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000757 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000756 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000756 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 3.1.106 FW Version : 3.1.106 Upgrading Ethernet PHY (Copper) This procedure upgrades the Ethernet PHY version of your controller. Before you begin This Ethernet PHY upgrade procedure applies only to Copper SKU (C9800-L-C-K9) model of the Cisco Catalyst 9800-L Wireless Controller. Use the show inventory command identify the model. Device# show inventory NAME: "Chassis 2", DESCR: "Cisco C9800-L-C-K9 Chassis" PID: C9800-L-C-K9 , VID: 01 , SN: FCW2328H00A Verify the current Ethernet PHY version on the standalone, active, or standby controllers using the following show commands: · Standalone Setup Device# show platform hardware chassis active qfp datapath pmd ifdev | i FW ========================================================== FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW Version : 0x80000757 : 9.1.2 ID: 43503 vers: 1376 : 0x80000757 : 9.1.2 ID: 43503 vers: 1376 : 0x80000756 : 9.1.2 ID: 43503 vers: 1376 : 0x80000756 : 9.1.2 ID: 43503 vers: 1376 : 3.1.76 : 3.1.76 · High-Availability Setup Run the following command on the active controller. Verify the current Ethernet PHY version for Active controller. Device# show platform hardware chassis active qfp datapath pmd ifdev | i FW ========================================================== FW Version FW MDIO : 0x80000757 : 9.1.2 ID: 43503 vers: 1376 Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 12 Upgrading Ethernet PHY (Copper) FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW Version : 0x80000757 : 9.1.2 ID: 43503 vers: 1376 : 0x80000756 : 9.1.2 ID: 43503 vers: 1376 : 0x80000756 : 9.1.2 ID: 43503 vers: 1376 : 3.1.76 : 3.1.76 Verify the current Ethernet PHY version for Standby controller. Device# show platform hardware chassis standby qfp datapath pmd ifdev | i FW ========================================================== FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW MDIO FW Version FW Version : 0x80000757 : 9.1.2 ID: 43503 vers: 1376 : 0x80000757 : 9.1.2 ID: 43503 vers: 1376 : 0x80000756 : 9.1.2 ID: 43503 vers: 1376 : 0x80000756 : 9.1.2 ID: 43503 vers: 1376 : 3.1.76 : 3.1.76 If any of the Ethernet PHY firmware (FW or MDIO) versions is earlier than the firmware version given in the show command output for the standalone, active, or standby controller, use the procedure given below to upgrade the Ethernet PHY firmware: Procedure Step 1 Step 2 Go to the software download page: https://software.cisco.com/download/home/286321399/type · Select IOS Hardware Programmable Devices. · Go to the release number. · Click on the download button for the C9800-L-hw-programmables.17.03.01.SPA.pkg. Copy the Ethernet PHY image to bootflash: using TFTP or USB. · TFTP: copy tftp://ip address of TFTP server/file path/C9800-L-hw-programmables.17.03.01.SPA.pkg bootflash: · USB: copy usb0: C9800-L-hw-programmables.17.03.01.SPA.pkg bootflash: After the system confirms that the copy operation is successful (sample output given below), proceed to the next step. Device# $copy tftp://9.1.0.101/PATH/FILENAME bootflash: Destination filename [C9800-L-hw-programmables.17.03.01.SPA.pkg ]? Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 13 Upgrading Ethernet PHY (Copper) Accessing tftp://9.1.0.101/c9800/C9800-L-hw-programmables.17.03.01.SPA.pkg Loading c9800/C9800-L-hw-programmables.17.03.01.SPA.pkg from 9.1.0.101 (via Vlan44): !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! [OK - 7805964 bytes] 7805964 bytes copied in 6.697 secs (1165591 bytes/sec) Step 3 Initiate the upgrade using the command given below and follow the instructions from the tool. Device# upgrade hw-programmable phy filename bootflash:C9800-L-hw-programmables.17.03.01.SPA.pkg Update PHY firmware on C9800-L platform. Upgrade Ver for AQR412 is 9.1.2.1385 Upgrade Ver for AQC107 is 3.1.76 PHY upgrade pending for Reboot. Please reboot to upgrade the firmware. Step 4 Reboot the controller by entering this command: Device# reload Reload command is being issued on Active unit, this will reload the whole stack Proceed with reload? [confirm] Chassis 1 reloading, reason - Reload command System Bootstrap, Version 17.03, RELEASE SOFTWARE Copyright (c) 1994-2019 by cisco Systems, Inc. Current image running: Boot ROM0 Last reset cause: LocalSoft The values of MSR 0x198h = 00001400 and MSR 0x199h = 00001400 for C9800-L C9800-L-X-K9 platform with 16777216 Kbytes of main memory File size is 0x38fed6b2 Located C9800-L-hw-programmables.17.03.01.SPA.pkg Image size 956225202 inode num 21, bks cnt 233454 blk size 8*512 ############################################################################################################## Boot image size = 956225202 (0x38fed6b2) bytes ROM:RSA Self Test Passed ROM:Sha512 Self Test Passed Package header rev 3 structure detected Calculating SHA-1 hash...done validate_package_cs: SHA-1 hash: calculated ce3982a2:f0737625:72fcbb02:93ed3683:b7fe0a2e expected ce3982a2:f0737625:72fcbb02:93ed3683:b7fe0a2e Validating main package signatures RSA Signed RELEASE Image Signature Verification Successful. Validating subpackage signatures Image validated Tue Feb 18 07:06:47 UTC 2020 Calling Aquantia Firmware upgrade process Tue Feb 18 07:07:40 UTC 2020 file: /bootflash/aq_phy_upgrade_info deleted Tue Feb 18 07:07:41 UTC 2020 Updating Phy firmware from pakage file = /bootflash/C9800-L-hw-programmables.17.03.01.SPA.pkg Tue Feb 18 07:07:41 UTC 2020 Bay0: Firmware: /tmp/hwprg_upgrade_pub/hwprog/RP/C9800-L/PHY/AQR412/upgrade_phy.cld Tue Feb 18 07:07:41 UTC 2020 Bay0: Firmware Version: 9.1.2.1385 Tue Feb 18 07:07:41 UTC 2020 Bay1: Firmware: /tmp/hwprg_upgrade_pub/hwprog/RP/C9800-L/PHY/AQC107/upgrade_phy.clx Tue Feb 18 07:07:41 UTC 2020 Bay1: Firmware Version: 3.1.76 Tue Feb 18 07:07:41 UTC 2020 /bootflash/C9800-L-hw-programmables.17.03.01.SPA.pkg is code signed Tue Feb 18 07:07:41 UTC 2020 ################################################################## Tue Feb 18 07:07:41 UTC 2020 # Please make sure POWER SUPPLY is always ON during this period. # Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 14 Upgrading Ethernet PHY (Copper) Tue Feb 18 07:07:42 UTC 2020 # Loss of POWER will completely kill this unit and make it # Tue Feb 18 07:07:42 UTC 2020 # unrecoverable # Tue Feb 18 07:07:42 UTC 2020 ################################################################## Tue Feb 18 07:07:42 UTC 2020 ################################################################# Tue Feb 18 07:07:42 UTC 2020 Aquantia Bay-0 upgrade firmware:/tmp/hwprg_upgrade_pub/hwprog/RP/C9800-L/PHY/AQR412/ upgrade_phy.cld found Tue Feb 18 07:07:42 UTC 2020 Aquantia firmware upgrade for Bay-0 started. Please wait. Tue Feb 18 07:07:42 UTC 2020 ################################################################# Tue Feb 18 07:07:43 UTC 2020 Current version of Bay-0 firmware: 9.1.0.1275 upgrade version: 9.1.2.1385 Tue Feb 18 07:09:43 UTC 2020 Aquantia firmware upgrade succeeded for Bay-0 Tue Feb 18 07:09:43 UTC 2020 ################################################################## Tue Feb 18 07:09:44 UTC 2020 ################################################################# Tue Feb 18 07:09:44 UTC 2020 Aquantia Bay-1 upgrade firmware:/tmp/hwprg_upgrade_pub/hwprog/RP/C9800-L/PHY/AQC107/ upgrade_phy.clx found Tue Feb 18 07:09:44 UTC 2020 Aquantia firmware upgrade for Bay-1 port-1 started Tue Feb 18 07:09:44 UTC 2020 ################################################################# Tue Feb 18 07:09:44 UTC 2020 Current version of Bay-1 port-1 firmware: 3.1.76 upgrade version: 3.1.76 Tue Feb 18 07:09:44 UTC 2020 Aquantia Bay-1 port-1 firmware version: 3.1.76 same as upgrade version file: 3.1.76 Tue Feb 18 07:09:44 UTC 2020 Skipping upgrade for Bay-1 port-1. Tue Feb 18 07:09:44 UTC 2020 ################################################################# Tue Feb 18 07:09:44 UTC 2020 Aquantia firmware upgrade for Bay-1 port-2 started Tue Feb 18 07:09:45 UTC 2020 ################################################################# Tue Feb 18 07:09:45 UTC 2020 Current version of Bay-1 port-1 firmware: 3.1.76 upgrade version: 3.1.76 Tue Feb 18 07:09:45 UTC 2020 Aquantia Bay-1 port-2 firmware version: 3.1.76 same as upgrade version file: 3.1.76 Tue Feb 18 07:09:45 UTC 2020 Skipping upgrade for Bay-1 port-2. Tue Feb 18 07:09:45 UTC 2020 Aquantia firmware upgrade completed successfully!!! Tue Feb 18 07:09:45 UTC 2020 Rebooting box Initializing Hardware ... Initializing Hardware ... System Bootstrap, Version 16.12(3r), RELEASE SOFTWARE Copyright (c) 1994-2019 by cisco Systems, Inc. Current image running: Boot ROM0 Last reset cause: PowerOn The values of MSR 0x198h = 00001400 and MSR 0x199h = 00001400 for C9800-L C9800-L-X-K9 platform with 16777216 Kbytes of main memory Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 15 Upgrading Ethernet PHY (Copper) Warning: filesystem is not clean File size is 0x38fed6b2 Located C9800-L-universalk9_wlc.16.12.02prd5.SPA.bin Image size 956225202 inode num 21, bks cnt 233454 blk size 8*512 ########################################################################################################### Boot image size = 956225202 (0x38fed6b2) bytes ROM:RSA Self Test Passed ROM:Sha512 Self Test Passed Package header rev 3 structure detected Calculating SHA-1 hash...done validate_package_cs: SHA-1 hash: calculated ce3982a2:f0737625:72fcbb02:93ed3683:b7fe0a2e expected ce3982a2:f0737625:72fcbb02:93ed3683:b7fe0a2e Validating main package signatures RSA Signed RELEASE Image Signature Verification Successful. Validating subpackage signatures Image validated Both links down, not waiting for other chassis Chassis number is 1 Step 5 Step 6 After the upgrade is complete, device power cycles automatically, and IOS prompt is displayed. Use the following show commands to verify the update on a standalone controller. Device# show platform hardware chassis active qfp datapath pmd ifdev | i FW ========================================================== FW Version : 0x80000757 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000757 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000756 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000756 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 3.1.76 FW Version : 3.1.76 Step 7 Use the following show commands to verify the update on a HA setup. a) To get the current Ethernet PHY version for active controller, use the following command: Device# show platform hardware chassis active qfp datapath pmd ifdev | i FW ========================================================== FW Version : 0x80000757 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000757 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000756 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000756 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 3.1.76 FW Version : 3.1.76 b) To get the current Ethernet PHY version for standby controller, use the following command: Device# show platform hardware chassis standby qfp datapath pmd ifdev | i FW ========================================================== FW Version : 0x80000757 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000757 FW MDIO : 9.1.2 ID: 43503 vers: 1385 FW Version : 0x80000756 FW MDIO : 9.1.2 ID: 43503 vers: 1385 Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 16 Upgrading Field Programmable for Cisco Catalyst 9800-80 Wireless Controller FW Version FW MDIO FW Version FW Version : 0x80000756 : 9.1.2 ID: 43503 vers: 1385 : 3.1.76 : 3.1.76 Upgrading Field Programmable for Cisco Catalyst 9800-80 Wireless Controller This section explains field programmable installation procedure for the Cisco Catalyst 9800-80 Wireless Controller. Before you begin Note To upgrade the ROMMON from 16.12(5R) (or a previous version) to higher versions, you should first upgrade ROMMON to 17.3(3r) and then to the desired version. This procedure applies to downgrades as well. To downgrade ROMMON from a higher version to 16.12(5R) (or an older version), you should first downgrade ROMMON to 17.3(3r) and then to 16.12(5R). · Upgrade path: 16.12(5R) > 17.3(3R) > 17.4(1R) · Downgrade path: 17.4(1R) > 17.3(3R) > 16.12(5R) Verify the current ROMMON version using the following commands: · Standalone Setup Device# show rom-monitor chassis active r0 ========================================================== System Bootstrap, Version 16.10(6r), RELEASE SOFTWARE Copyright (c) 1994-2019 by Cisco Systems, Inc. · High-Availability Setup Run the following command on the active controller. Verify the current ROMMON version for Active controller: Device# show rom-monitor chassis active r0 System Bootstrap, Version 16.10(6r), RELEASE SOFTWARE Copyright (c) 1994-2019 by Cisco Systems, Inc. Verify the current ROMMON version for Standby controller: Device# show rom-monitor chassis standby r0 ========================================================== System Bootstrap, Version 16.10(6r), RELEASE SOFTWARE Copyright (c) 1994-2019 by cisco Systems, Inc. Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 17 Upgrading Field Programmable for Cisco Catalyst 9800-80 Wireless Controller If you ROMMON version is earlier than 16.12(5r) for the standalone, active, or standby controller, use the procedure given below: Procedure Step 1 Step 2 Go to the software download page: https://software.cisco.com/download/home/286321396/type · Select IOS XE ROMMON Software. · Go to the release number. · Click on the download button for the C9800-80-rommon.1612-5r.pkg. Copy the ROMMON image to bootflash, using TFTP or USB. · TFTP: copy tftp://ip address of TFTP server/file path/ C9800-80-rommon.1612-5r.pkg bootflash: · USB: copy usb0: C9800-80-rommon.1612-5r.pkg bootflash: After the system confirms that the copy operation is successful (sample output given below), proceed to the next step. Device# $copy tftp://9.1.0.101/PATH/FILENAME bootflash: Destination filename [C9800-80-rommon.1612-5r.pkg]? Accessing tftp://9.1.0.101/c9800/C9800-80-rommon.1612-5r.pkg... Loading c9800/ C9800-80-rommon.1612-5r.pkg from 9.1.0.101 (via Vlan44): !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! [OK - 7805964 bytes] 7805964 bytes copied in 6.697 secs (1165591 bytes/sec) Step 3 Initiate the upgrade using the command given below and follow the instructions from the tool. Device# upgrade rom-monitor filename bootflash:C9800-80-rommon.1612-5r.pkg chassis active r0 Verifying the code signature of the ROMMON package... Chassis model C9800-80-K9 has a single rom-monitor. Upgrade rom-monitor Target copying rom-monitor image file Secure update of the ROMMON image will occur after a reload. 131072+0 records in 131072+0 records out 131072 bytes (131 kB, 128 KiB) copied, 0.461893 s, 284 kB/s Copying ROMMON environment 131072+0 records in 131072+0 records out 131072 bytes (131 kB, 128 KiB) copied, 0.80982 s, 162 kB/s Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 18 Upgrading Field Programmable for Cisco Catalyst 9800-80 Wireless Controller 131072+0 records in 131072+0 records out 131072 bytes (131 kB, 128 KiB) copied, 0.801238 s, 164 kB/s ROMMON upgrade complete. To make the new ROMMON permanent, you must restart the RP. Step 4 Reboot the controller by entering this command: Device# reload Reload command is being issued on Active unit, this will reload the whole stack Proceed with reload? [confirm] *Feb 12 05:43:27.912: %SYS-5-RELOAD: Reload requested by console. Reload Reason: Reload Command. Chassis 1 reloading, reason - Reload command Feb 12 05:43:33.012: %PMAN-5-EXITACTION: F0/0: pvp: Process manager is exiting: Feb 12 05:43:33.028: %PMAN-5-EXITACTION: C0/0: pvp: Process manager is exiting: Feb 12 05:43:34.210: Initializing Hardware ... System integrity status: 90170200 12030107 System Bootstrap, Version 16.10(6r), RELEASE SOFTWARE Copyright (c) 1994-2018 by cisco Systems, Inc. Current image running: Boot ROM0 Last reset cause: LocalSoft C9800-80-K9 platform with 67108864 Kbytes of main memory Successfully initiated a secure capsule update. The system will be reset multiple times for completing the capsule update. Please wait till you get the prompt. Initializing Hardware ... System integrity status: 90170200 12030107 Insyde H2OFFT (Flash Firmware Tool) Version (SEG) 100.00.09.02 Copyright (C) 2018 Insyde Software Corp. All Rights Reserved. Platform Name: Purley Current Version: Purley.05.21.51.0058 Update Version: Purley.05.21.51.0058 Updating Block at FDFF0000h 0% Updating Block at FE042000h 1% Updating Block at FF005000h 50% Updating Block at FFFFE000h 99% Updating Block at FFFFF000h 100% Updating Block at FFFFF000h 100% Initializing Hardware ... System integrity status: 90170200 12030107 System Bootstrap, Version 16.10(6r), RELEASE SOFTWARE Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 19 Upgrading Field Programmable for Cisco Catalyst 9800-80 Wireless Controller Copyright (c) 1994-2018 by cisco Systems, Inc. Current image running: Boot ROM0 Last reset cause: PowerCycleRequest C9800-80-K9 platform with 67108864 Kbytes of main memory Secure capsule update was successful Capsule Processed : 02/12/2020 05:51 UTC Capsule Status : Success Flash upgrade reset 1 in progress ........ Initializing Hardware ... System integrity status: 90170200 12030107 System Bootstrap, Version 16.10(6r), RELEASE SOFTWARE Copyright (c) 1994-2018 by cisco Systems, Inc. Current image running: Boot ROM0 Last reset cause: PowerCycleRequest C9800-80-K9 platform with 67108864 Kbytes of main memory Secure capsule update was successful Capsule Processed : 02/12/2020 05:51 UTC Capsule Status : Success Flash upgrade reset 2 in progress ........ Initializing Hardware ... System integrity status: 90170200 12030117 System Bootstrap, Version 16.12(5r), RELEASE SOFTWARE Copyright (c) 1994-2019 by cisco Systems, Inc. Current image running: *Upgrade in progress* Boot ROM1 Last reset cause: BootRomUpgrade C9800-80-K9 platform with 67108864 Kbytes of main memory File size is 0x392a32f3 Located C9800-80-universalk9_wlc.16.12.01t.SPA.bin Image size 959066867 inode num 12, bks cnt 234148 blk size 8*512 ############################################################################################################# Boot image size = 959066867 (0x392a32f3) bytes ROM:RSA Self Test Passed ROM:Sha512 Self Test Passed Package header rev 3 structure detected Calculating SHA-1 hash...done validate_package_cs: SHA-1 hash: Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 20 Upgrading Field Programmable for Cisco Catalyst 9800-80 Wireless Controller calculated 026dcd56:56c756c1:68aaf4a2:cd5208af:b2412efe expected 026dcd56:56c756c1:68aaf4a2:cd5208af:b2412efe Validating main package signatures RSA Signed RELEASE Image Signature Verification Successful. Validating subpackage signatures Image validated Both links down, not waiting for other chassis Chassis number is 1 Feb 12 05:57:59.083: %PMAN-3-PROC_EMPTY_EXEC_FILE: R0/0: pvp: Empty executable used for process bt_logger Feb 12 05:58:00.630: %PMAN-3-PROC_EMPTY_EXEC_FILE: R0/0: pvp: Empty executable used for process bt_logger Feb 12 05:58:01.972: %PMAN-3-PROC_EMPTY_EXEC_FILE: R0/0: pvp: Empty executable used for process bt_logger Feb 12 05:58:08.654: %PMAN-3-PROC_EMPTY_EXEC_FILE: R0/0: pvp: Empty executable used for process bt_logger Feb 12 05:58:10.459: %PMAN-3-PROC_EMPTY_EXEC_FILE: R0/0: pvp: Empty executable used for process bt_logger Feb 12 05:58:12.889: %PMAN-3-PROC_EMPTY_EXEC_FILE: R0/0: pvp: Empty executable used for process bt_logger Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Commercial Computer Software - Restricted Rights clause at FAR sec. 52.227-19 and subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS sec. 252.227-7013. Cisco Systems, Inc. 170 West Tasman Drive San Jose, California 95134-1706 Cisco IOS Software [Gibraltar], C9800 Software (C9800_IOSXE-K9), Version 16.12.1t, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2020 by Cisco Systems, Inc. Compiled Tue 14-Jan-20 04:45 by mcpre This software version supports only Smart Licensing as the software licensing mechanism. PLEASE READ THE FOLLOWING TERMS CAREFULLY. INSTALLING THE LICENSE OR LICENSE KEY PROVIDED FOR ANY CISCO SOFTWARE PRODUCT, PRODUCT FEATURE, AND/OR SUBSEQUENTLY PROVIDED SOFTWARE FEATURES (COLLECTIVELY, THE "SOFTWARE"), AND/OR USING SUCH SOFTWARE CONSTITUTES YOUR FULL ACCEPTANCE OF THE FOLLOWING TERMS. YOU MUST NOT PROCEED FURTHER IF YOU ARE NOT WILLING TO BE BOUND BY ALL THE TERMS SET FORTH HEREIN. Your use of the Software is subject to the Cisco End User License Agreement (EULA) and any relevant supplemental terms (SEULA) found at http://www.cisco.com/c/en/us/about/legal/cloud-and-software/software-terms.html. You hereby acknowledge and agree that certain Software and/or features are licensed for a particular term, that the license to such Software and/or features is valid only for the applicable term and that such Software and/or features may be shut down or otherwise terminated by Cisco after expiration of the applicable license term (e.g., 90-day trial period). Cisco reserves Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 21 Upgrading Field Programmable for Cisco Catalyst 9800-40 Wireless Controllers the right to terminate any such Software feature electronically or by any other means available. While Cisco may provide alerts, it is your sole responsibility to monitor your usage of any such term Software feature to ensure that your systems and networks are prepared for a shutdown of the Software feature. FIPS: Flash Key Check : Key Not Found, FIPS Mode Not Enabled All TCP AO KDF Tests Pass cisco C9800-80-K9 (2DA) processor (revision 2DA) with 9903871K/6147K bytes of memory. Processor board ID FXS2312Q2U5 1 Virtual Ethernet interface 18 Ten Gigabit Ethernet interfaces 32768K bytes of non-volatile configuration memory. 67108864K bytes of physical memory. 26255359K bytes of eUSB flash at bootflash:. 234365527K bytes of SATA hard disk at harddisk:. 0K bytes of WebUI ODM Files at webui:. Base Ethernet MAC Address : 10:B3:D5:A5:84:00 Installation mode is BUNDLE Press RETURN to get started! *Nov 27 11:17:18.273: %SMART_LIC-6-EXPORT_CONTROLLED: Usage of export controlled features is not allowed Adding registry invocations for the WLC platform *Nov 27 11:17:19.690: %SMART_LIC-6-AGENT_READY: Smart Agent for Licensing is initialized *Nov 27 11:17:19.690: %SMART_LIC-6-AGENT_ENABLED: Smart Agent for Licensing is enabled *Nov 27 11:18:00.374: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet0/1/1, changed state to up *Nov 27 11:18:07.446: %SMART_LIC-6-EXPORT_CONTROLLED: Usage of export controlled features is not allowed *Nov 27 11:18:07.446: %CALL_HOME-6-CALL_HOME_ENABLED: Call-home is enabled by Smart Agent for Licensing. Step 5 Verify the update on both active and standby controllers by entering this command: Device# show rom-monitor chassis active r0 ========================================================== System Bootstrap, Version 16.12(5r), RELEASE SOFTWARE Copyright (c) 1994-2019 by cisco Systems, Inc. Upgrading Field Programmable for Cisco Catalyst 9800-40 Wireless Controllers This section explains field programmable installation procedure for the Cisco Catalyst 9800-40 Wireless Controller. Before you begin Verify the current ROMMON version on the standalone, active, or standby controllers using the following show commands: · Standalone Setup Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 22 Device# show rom-monitor chassis active r0 ========================================================== System Bootstrap, Version 16.10(2r), RELEASE SOFTWARE Copyright (c) 1994-2018 by cisco Systems, Inc. · High-Availability Setup Run the following commands on the active controller. Verify the current ROMMON version for Active controller: Device# show rom-monitor chassis active r0 ========================================================== System Bootstrap, Version 16.10(2r), RELEASE SOFTWARE Copyright (c) 1994-2018 by cisco Systems, Inc. Verify the current ROMMON version for Standby controller: Device# show rom-monitor chassis standby r0 ========================================================== System Bootstrap, Version 16.10(2r), RELEASE SOFTWARE Copyright (c) 1994-2018 by cisco Systems, Inc. Resolved Caveats Note If your ROMMON version is 16.10(2r) for the standalone, active, or standby controller, no action is required, as you have the latest software. Procedure If your ROMMON version is earlier than 16.10(2r) for the standalone, active, or standby controller, contact Cisco TAC. Resolved Caveats Cisco Catalyst 9800-L Wireless Controller Table 1: ROMMON Release 16.12(3r) Caveat ID Description CSCvq88840 9800-L: Fan always runs at maximum speed and is very loud. CSCvr72052 9800-L: Default config register disables breaking into ROMMON, preventing password recovery. Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 23 Resolved Caveats Table 2: Ethernet PHY Caveat ID Description CSCvq48018 9800-L: MAC congested @Low PPS, drops/TX_XOFF in Bay 0-Tune settings and pause frames in mgig ports CSCvq70386 9800-L-F: The show hw-module subslot 0/1 transceiver 0 idprom brief command failed to display output. CSCvs15116 9800L-F: Bay-1 Onegig and TenGigabitEthernet0/1/0 are not coming up when Bay-1 FW upgraded to 3.1.96 Cisco Catalyst 9800-80 Wireless Controller Table 3: ROMMON Release 16.12(5r) Caveat ID Description CSCvp25150 Support booting of higher size images. Upgrading Field Programmable Hardware Devices for Cisco Catalyst 9800 Series Wireless Controllers 24 © 2020 Cisco Systems, Inc. All rights reserved.DITA Open Toolkit XEP 4.9 build 20070312; modified using iText 2.1.7 by 1T3XT