Mastech MS8907 Non-Contact AC Voltage Detector
Quick Start Guide
Company Information
EMEA: MGL EUMAN S.L., C/ Picu Castiellu, Parcelas i1-i4 33163, Argame Morcín, Asturias, Spain. Tel: +34 985-08-18-70, Email: cs.emea@mgl-intl.com
USA: MGL AMERICA, INC., 2810 Coliseum Centre Drive, Ste. 100 Charlotte, North Carolina 28217 USA. Tel: +1 833-533-5899, Email: cs.na@mgl-intl.com
UNITED KINGDOM: MGL GROUP U.K. LIMITED, 14 Weller St, London, SE1 1QU, UK. Tel: +34 985-08-18-70, Email: cs.uk@mgl-intl.com
MEXICO & LATAM: MGL LATAM S.A DE CV, Colonia Industrial Vallejo Del. Azcapotzalco 02300, Mexico D.F. Tel: +1 833-533-5899, Email: cs.latam@mgl-intl.com
APAC: MGL APPA Corporation, Flat 4-1, 4/F, No. 35, Section 3 Minquan East Road, Taipei, Taiwan. Tel: +886 2-2508-0877, Email: cs.apac@mgl-intl.com
Important Safety Precautions
Special attention should be paid when using test and measurement instruments. Improper usage may cause electric shock and damage the equipment.
- Use proper measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.
- Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
- When handling test probes and crocodile clips, keep fingers behind the physical guard.
- Examine test leads before use. If insulation is deteriorated, replace them with proper functional test leads.
- Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
- Before measuring current, ensure the instrument fuses are available and disconnect the power supply to the circuit being tested.
- Remove batteries if the device is not used for an extended period or is stored in temperatures above 45°C to prevent battery leakage and damage.
Specifications
Non-Contact AC Voltage Detector (AC Voltage Range) | 50~1000V |
Frequency | 50Hz~60Hz |
Product Overview
The Mastech MS8907 is a non-contact AC voltage detector designed for safely identifying the presence of AC voltage without direct contact.
Operating Instructions
Step 1: Battery Installation
Insert batteries into the device as indicated.
Step 2: Voltage Detection
- Turn on the device by pressing the power button. A green indicator light will illuminate.
- Bring the tip of the detector near an AC voltage source.
- If AC voltage is detected, the device will emit an audible beep and the indicator light will turn red.
Diagram Description:
The diagram shows the MS8907 detector. In the first part, it illustrates the battery compartment being opened. In the second part, it shows the detector being brought near an electrical outlet. When voltage is detected, an indicator light turns red and an audible beep is heard.
Certifications and Warranty
The product is certified by Intertek and meets CE and EAC standards. It comes with a 1-year limited warranty.