YDI Wireless USB-ANT-E WLAN Card w/USB NM5-USB-ANT-E NM5USBANTE usb ant e
EMV-Prüfzentrum EMI/EMC-Testcenter Straubing, June 25, 1999 T E S T - R E P O R T No. 56305-90389-1 for LUC PC24-H-FC RF-modem for wireless LAN Applicant: Purpose of testing: Lucent Technologies Nederland B.V. To show compliance with FCC Code of Federal Regulations, Part 15 Subpart C, Section §15.247 Note: The test data of this report relate only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Page 1 of 81 Pages Table of Contents EMV-Prüfzentrum EMI/EMC-Testcenter 1. Administrative Data ....................................................................................3 2. Identification of Test Laboratory .................................................................4 3. Summary of Test Results ...........................................................................5 4. Operation Mode of EUT..............................................................................6 5. Configuration of EUT and Peripheral Devices............................................8 6. Setup of Host..............................................................................................9 7. Measuring Methods ..................................................................................10 7.1. Maximum Peak Output Power (§ 15.247.b)........................................10 7.2. Radiated Emission 30 MHz - 1 GHz (§15.209, §15.247.c, §15.205.a,b) .......................................................................................11 7.3. Radiated Emission 1 GHz - 25 GHz (§15.209, §15.247.c, §15.205.a,b) .......................................................................................13 8. Equipment List..........................................................................................15 9. Photographs Taken During Testing..........................................................17 10. List of Measurements ...............................................................................21 11. Test Results..............................................................................................22 FCC-ID: IMRWLPC24H Page 2 of 81 Pages Test Report No. 56305-90389-1 1. Administrative Data EMV-Prüfzentrum EMI/EMC-Testcenter Equipment Under Test (EUT): Serial number(s): Type of equipment: Parts/accessories: FCC-ID: LUC PC24-H-FC 92290006 Sample no. 1 (RF-modem) (external antenna) RF-modem using DSSS technology for wireless connection for e.g. portable and mobile computers which have a PCMCIA-bus. · RF-modem LUC PC24-H-FC, part no. 011683/B · external omni-directional antenna AIN24-OD- 0202, part no. 010096 (for additional information see "Configuration of EUT and Peripheral Devices" on page 8) IMRWLPC24H Applicant: (full address) Contract identification: Contact person: Manufacturer: Lucent Technologies Nederland B.V. Zadelstede 1-10 NL-3431 JZ Nieuwegein The Netherlands --- Mr. Wout Kerkhof Lucent Technologies Nederland B.V. Receipt of EUT: Date of test: Note: June 14, 1999 June 16 to 24, 1999 --- Responsible for testing: Responsible for test report: Rainer Heller Rainer Heller FCC-ID: IMRWLPC24H Page 3 of 81 Pages Test Report No. 56305-90389-1 2. Identification of Test Laboratory EMV-Prüfzentrum EMI/EMC-Testcenter Test Laboratory: (full address): Senton GmbH EMI/EMC Test Center Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Contact person: Communication: Mr. Johann Roidt Telephone Fax eMail: (+49) 0 94 21 / 55 22-0 (+49) 0 94 21 / 55 22-99 Office@senton.de FCC file number: 31040/SIT 1300F2 Industry Canada file number: IC 3050 FCC-ID: IMRWLPC24H Page 4 of 81 Pages Test Report No. 56305-90389-1 3. Summary of Test Results EMV-Prüfzentrum EMI/EMC-Testcenter The tested sample (including accessories) complies with the requirements for · maximum peak output power (§15.247.b) and · radiated emission (§15.247.c, §15.205.a,b, §15.209) set forth in the Code of Regulations Part 15 Subpart C, Section §15.247 (intentional radiators) of the Federal Communication Commission (FCC). Johann Roidt Technical Manager Rainer Heller Test Engineer FCC-ID: IMRWLPC24H Page 5 of 81 Pages Test Report No. 56305-90389-1 4. Operation Mode of EUT EMV-Prüfzentrum EMI/EMC-Testcenter All tests were performed using the "WaveLAN-II Engineering Test Program", Version v01.17c (May 6 1999). According to applicant three different kinds of modulation are used for transmission specified by the appropriate bit rate: Transmit mode (TX): Operating frequency [GHz] 2.412 2.417 2.422 2.427 2.432 2.437 2.442 2.447 2.452 2.457 2.462 Rated output power (conducted) [dBm] Bit rate 2 Mbps Bit rate 5.5 Mbps Bit rate 11 Mbps +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 +15 Test performed 1 X X X Receive mode (RX): Operating frequency [GHz] 2.412 2.417 2.422 2.427 2.432 2.437 2.442 2.447 2.452 2.457 2.462 Test performed X Note: See next page for instructions supplied by applicant to achieve required operation mode. 1 Full testing with bit rate 11 Mbps only FCC-ID: IMRWLPC24H Page 6 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter INSTRUCTIONS - TEST PROGRAM WaveLAN Engineering Test Program, V01.17c, May 6, 1999 SETUP · INSERT Modem · INSERT Test Program disk · SWITCH ON PC · GO TO A:\ · TYPE Cert_eng · MAIN MENU appears · SELECT INITIALISE and ENTER · INITIALISE appears for a short time, green power LED is on · Program returns automatically to MAIN MENU CHANNEL SELECTION · SELECT SET CHANNEL from MAIN MENU and ENTER · SELECT channel and ENTER · RESULTS appear · ESC (back to MAIN MENU) TX MODE · SELECT TX CONTINUOUS ON from MAIN MENU and ENTER, · SET BIT RATE parameters: 2Mbps, 5.5Mbps or 11Mbps and ENTER (Modem transmits spectrum with specified bit rate on selected channel. Both LEDs are on. Check by spectrum analyzer) · To stop transmission SELECT RX CONTINUOUS ON / STOP and ENTER · To restart transmission SELECT TX CONTINUOUS ON and ENTER two times · NOTE: Before changing the channel number INITIALISE has to be selected first. For further details see Channel Selection above. RX MODE · SELECT RX CONTINUOUS ON / STOP from MAIN MENU and ENTER · NOTE: Before changing the channel number INITIALISE has to be selected first. For further details see Channel Selection above. CHANNEL LIST Channel ID 01 02 03 04 05 06 07 08 09 10 11 FCC (MHz) 2412 2417 2422 2427 2432 2437 2442 2447 2452 2457 2462 FCC-ID: IMRWLPC24H Page 7 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter 5. Configuration of EUT and Peripheral Devices RF-modem module LUC PC24-H-FC was tested operating with external antenna AIN24-OD-0202 connected (1.5 m antenna cable) and mounted in PCMCIA slot of notebook AT & T Globalyst 200. In table 1 used accessories and host equipment (with Lucent part numbers) are listed. Item RF-modem External omnidirectional antenna Notebook Part no. 011683/B 010096 Serial no. 92290006 Sample no. 1 Designation LUC PC24-H-FC AIN24-OD-0202 --- 017-28730433 Globalyst 200 Table 1: Accessories and host equipment Manufacturer Lucent Lucent AT & T FCC-ID: IMRWLPC24H Page 8 of 81 Pages Test Report No. 56305-90389-1 6. Setup of Host EMV-Prüfzentrum EMI/EMC-Testcenter Configuration of cables of host · Unshielded power lines for AC-power supply of notebook, Kawasaki, 180 cm · Shielded data cable connected to parallel interface of notebook, Inmac, 150 cm, Senton inv.-no. 1387 · Shielded data cable connected to serial interface of personal computer, Senton, 220 cm, Senton inv.-no. 1401 Configuration of host and peripheral devices · Notebook AT & T Globalyst 200: Serial no.: 017-28730433 FCC-ID: A3LS3945 with AC power supply AT & T AC Adapter: Product ID: 3150-K909-V001 Part no.: 5290000117 · PS/2-keyboard HP C1405A #ABD: Serial no.: 3221S30020 FCC-ID2: B94VECTRA386S-20 · Parallel printer HP ThinkJet 2225C+: Serial no.: 3106S91193 FCC-ID: DSI6XU2225 with power supply Hayes 52-00008 Serial no.: 9028A · Serial printer HP ThinkJet 2225D+: Serial no.: 2920S44042 FCC-ID: DSI6XU2225 with power supply Hayes 52-00008 Serial no.: 9033A 2 FCC-ID of corresponding personal computer FCC-ID: IMRWLPC24H Page 9 of 81 Pages Test Report No. 56305-90389-1 7. Measuring Methods EMV-Prüfzentrum EMI/EMC-Testcenter 7.1. Maximum Peak Output Power (§ 15.247.b) The maximum peak output power was measured with a power meter connected to the antenna connector (conducted measurement) while EUT was operating in transmit mode at the appropriate center frequency. See figure 1 for the measurement setup. Test equipment used (see equipment list for details): 02, 08, 09, 18, 67, 68 115 V AC 6 2 3 1 5 7 4 8 9 11 10 Figure 1: Measurement setup for testing on antenna connector 1 Notebook 2 Power supply for notebook 3 RF-modem (EUT) 4 Wooden table 5 Adapter cable 6 DC-block 7 Test cable 8 Attenuator 9 Spectrum analyzer 10 Power sensor 11 Power meter FCC-ID: IMRWLPC24H Page 10 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter 7.2. Radiated Emission 30 MHz - 1 GHz (§15.209, §15.247.c, §15.205.a,b) Radiated emissions were measured over the frequency range from 30 MHz to 1 GHz. The bandwidth of the EMI-receiver was set to 120 kHz and the detectorfunction was set to CISPR quasi-peak. The test setup was made in accordance with ANSI C63.4-1992. Measurements were made in both the horizontal and vertical planes of polarization. Preliminary scans were taken in a semi-anechoic room using a spectrum analyzer with the detector function set to peak. All tests were performed at a test-distance of 3 meters. For final testing an open-area test-site was used. During the tests the EUT was rotated all around and the receiving-antenna was raised and lowered from 1 meter to 4 meters to find the maximum levels of emissions. The cables and equipment were placed and moved within the range of position likely to find their maximum emissions. See figure 2 for the measurement setup. Test equipment used (see equipment list for details): 01, 06, 12, 38, 39, 40, 41, 58, 61, 64, 66 FCC-ID: IMRWLPC24H Page 11 of 81 Pages Test Report No. 56305-90389-1 8 6 115 V AC 4 31 5 2 7 11 EMV-Prüfzentrum EMI/EMC-Testcenter test-distance 3 m 9 10 Figure 2: Measurement setup for radiated emission test below 1 GHz 1 Notebook 2 Power supply for notebook 3 RF-modem (EUT) 4 RF-antenna (2.4 GHz) 5 Keyboard 6 Parallel printer 7 Serial printer 8 Wooden table 9 Measurement antenna 10 Test receiver 11 Turn table FCC-ID: IMRWLPC24H Page 12 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter 7.3. Radiated Emission 1 GHz - 25 GHz (§15.209, §15.247.c, §15.205.a,b) Radiated emissions were measured in the frequency range 1 GHz to 25 GHz in transmit mode and 1 GHz to 12.5 GHz in receive mode. The resolution bandwidth of the spectrum analyzer was set to 1 MHz. Scans for the whole frequency range were taken with video bandwidth set to 1 MHz to check out the highest peak levels. In case of less margin to average limit additional prescans were made with video bandwidth reduced from 1 MHz to 100 kHz, 30 kHz or 10 kHz. Final measurements were performed at the critical frequencies with video bandwidth of the spectrum analyzer set to 100 Hz (average mode). EUT was rotated all around and receiving antenna was raised and lowered to find the maximum levels of emission. Cables and equipment were placed and moved within the range of position likely to find their maximum emissions. All tests were performed in a semi-anechoic chamber with a test-distance of 3 meters (except for the frequency range 18 GHz - 25 GHz where test distance was reduced to 0.5 meter). To avoid overload in transmit mode no preamplifier was used between 1 GHz and 3.95 GHz. Above 3.95 GHz tests were performed with appropriate preamplifiers (attenuation of operating frequency by horn antenna is sufficient to avoid overload of preamplifier). For receive mode appropriate preamplifiers were used for the whole frequency range. To eliminate variations in amplification of the preamplifiers a signal generator was used for substitution (however, during testing a correction according to the minimum amplification was added). Substitution was performed in the following steps: - antenna cable was disconnected from receiving antenna and connected to signal generator output - level of signal generator was increased until the reading value of the analyzer was the same as caused by EUT - level of signal generator was noted - final value was calculated by converting the signal generator level to dBµV/m and adding the antenna correction factor. See figure 3 for the measurement setups. Test equipment used (see equipment list for details): 02, 13, 14, 16, ,42, 43, 44, 45, 46, 47, 48, 49, 57, 64 FCC-ID: IMRWLPC24H Page 13 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter test-distance 3 meters 4 2 115 V AC 31 5 9 8 6 7 10 Figure 3: Measurement setup for radiated emission test above 1 GHz 1 Notebook 2 Power supply for notebook 3 RF-modem (EUT) 4 RF-antenna (2.4 GHz) 5 Measurement antenna 6 Preamplifier (if applicable) 7 Spectrum analyzer 8 Signal generator 9 Turn table 10 Semi-anechoic room FCC-ID: IMRWLPC24H Page 14 of 81 Pages Test Report No. 56305-90389-1 8. Equipment List EMV-Prüfzentrum EMI/EMC-Testcenter To facilitate reference to test equipment used for related tests, each item of test equipment and ancillaries such as cables are identified (numbered) by the Test Laboratory. No. Type 01 Spectrum Analyzer 02 EMI Test Receiver 03 Test Receiver 04 Test Receiver 05 Test Receiver 06 Test Receiver 07 Audio Analyzer 08 Power Meter 09 Power Sensor 10 Power Sensor 11 Preamplifier 12 Preamplifier 13 Preamplifier 14 Preamplifier 15 Signal Generator 16 Signal Generator 17 Waveform Generator 18 Attenuator 20 dB 19 Attenuator 10 dB 20 Pulse Limiter 21 Pulse Limiter 22 V-Network 23 V-Network 24 V-Network 25 V-Network 26 V-Network 27 V-Network 28 V-Network 29 T-Network 30 T-Network 31 High Impedance Probe 32 High Impedance Probe 33 Current Probe 34 Current Probe Model R 3271 ESMI ESH 3 ESHS 10 ESV ESVP UPA NRVS NRV-Z52 NRV-Z4 ESV-Z3 R14601 ACX/080-3030 ACO/180-3530 SMS HP 8673 D HP 33120 A 4776-20 4776-10 ESH 3-Z2 11947 A ESH 3-Z5 ESH 3-Z5 ESH 3-Z5 ESH 3-Z6 NSLK 8127 NNLA 8119 SE 01 ESH 3-Z4 ESH 3-Z4 TK 9416 TK 9416 ESH 2-Z1 ESV-Z1 Serial Number 05050023 839379/013 839587/006 880112/032 860043/016 881414/009 881120/024 862954 836856/015 837901/030 863828/015 860907/004 32640 32641 872166/039 2930A00966 US34005375 9503 9412 1144 3107A00566 862770/018 894785/005 830952/025 830722/010 8127152 8119148 01 890602/011 890602/012 01 02 863366/18 862553/3 Manufacturer Advantest Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Advantest CTT CTT Rohde & Schwarz Hewlett Packard Hewlett Packard Narda Narda Rohde & Schwarz Hewlett Packard Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Schwarzbeck Schwarzbeck Senton Rohde & Schwarz Rohde & Schwarz Schwarzbeck Schwarzbeck Rohde & Schwarz Rohde & Schwarz FCC-ID: IMRWLPC24H Page 15 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter No. Type 35 Absorbing Clamp 36 Absorbing Clamp 37 Loop Antenna 38 Biconical Antenna 39 Biconical Antenna 40 Log. Periodic Antenna 41 Log. Periodic Antenna 42 Horn Antenna 43 Horn Antenna 44 Horn Antenna 45 Horn Antenna 46 Horn Antenna 47 Horn Antenna 48 Horn Antenna 49 Horn Antenna 50 Digital multimeter 51 DC Power Supply 52 DC Power Supply 53 DC Power Supply 54 Temperature Test Chamber 55 Cable 56 Cable 57 Cable 58 Cable Set EG1 59 Cable Set Cabine 1 60 Cable Set Cabine 2 61 Cable Set Cabine 3 62 Shielded Room 63 Shielded Room 64 Semi-anechoic Chamber 65 Shielded Room 66 Open Area Test Site 67 Cable for Antenna Connector 68 DC Block 0.01-18GHz 69 High pass filter Model MDS 21 MDS 21 HFH2-Z2 HK 116 HK 116 HL 223 HL 223 3115 3160-03 3160-04 3160-05 3160-06 3160-07 3160-08 3160-09 199 NGSM 32/10 NGB NGA HT4010 RG214 200CM_001 150CM_001 RG214 RG214 RG214 RG214 No. 1 No. 2 No. 3 No. 4 EG 1 Serial Number 80911 79690 882964/1 842204/001 836239/02 841516/023 834408/12 9508-4553 9112-1003 9112-1001 9112-1001 9112-1001 9112-1008 9112-1002 9403-1025 463386 203 2455 386 07065550 1309 1357 1479 1189 - 1191 1451 1452 1453 1454 8037 Manufacturer Lüthi Lüthi Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Emco Emco Emco Emco Emco Emco Emco Emco Keithley Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Heraeus Senton Rosenberger Rosenberger Senton Senton Senton Senton Senton Senton Siemens Euroshield Senton Lucent Technologies Inmet Corp. Lucent Technologies FCC-ID: IMRWLPC24H Page 16 of 81 Pages Test Report No. 56305-90389-1 9. Photographs Taken During Testing EMV-Prüfzentrum EMI/EMC-Testcenter FCC-ID: IMRWLPC24H Page 17 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter Photos No. 9.1 - 9.2 Test setup for radiated emission pre-test 30 MHz - 1 GHz (semi anechoic room) FCC-ID: IMRWLPC24H Page 18 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter Photos No. 9.3 - 9.4 Test setup for radiated emission final test 30 MHz - 1 GHz (open area test site) FCC-ID: IMRWLPC24H Page 19 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter Photos No. 9.5 - 9.6 Test setup for radiated emission test above 1 GHz FCC-ID: IMRWLPC24H Page 20 of 81 Pages Test Report No. 56305-90389-1 10. List of Measurements EMV-Prüfzentrum EMI/EMC-Testcenter FCC Part 15 Subpart C Section(s): Test §15.247.a2 §15.247.b §15.247.d §15.247.e §15.207 §15.247.c §15.209 §15.205.a,b §15.247.c §15.209 §15.205.a,b §15.247.c §15.209 §15.205.a,b Transmit mode (TX): Minimum 6 dB bandwidth Maximum peak output power Peak power density Processing gain Conducted emission test 450 kHz - 30 MHz Radiated emission test 9 kHz - 30 MHz Radiated emission test 30 MHz - 1 GHz Radiated emission test 1 GHz - 25 GHz §15.207 §15.209 §15.209 §15.209 Receive mode (RX): Conducted emission test 450 kHz - 30 MHz Radiated emission test 9 kHz - 30 MHz Radiated emission test 30 MHz - 1 GHz Radiated emission test 1 GHz - 12.5 GHz Page Result 23 --- not performed 24 passed --- not performed --- test performed by applicant --- not performed --- not applicable (acc. to §15.33) 25 passed 52 passed 70 --- not performed --- not applicable (acc. to §15.33) 71 passed 80 passed Note 1: Extent of testing was defined by applicant. For full testing of previous version see Senton test report no. 56305-90203-1. Note 2: Maximum peak output power was measured while either using bit rate 2, 5.5 or 11 Mbps. Radiated emission tests in transmit mode were performed with bit rate set to 11 Mbps only. FCC-ID: IMRWLPC24H Page 21 of 81 Pages Test Report No. 56305-90389-1 11. Test Results EMV-Prüfzentrum EMI/EMC-Testcenter FCC-ID: IMRWLPC24H Page 22 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter Test results for Transmit (TX) mode FCC-ID: IMRWLPC24H Page 23 of 81 Pages Test Report No. 56305-90389-1 EMV-Prüfzentrum EMI/EMC-Testcenter Maximum Peak Output Power according to FCC Part 15 Subpart C, §15.247b Model: Type: Serial No.: Applicant: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 90890026 Lucent Technologies Nederland B.V. 03/23/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - TX mode Tested on: Antenna connector Selected bit rate 2 Mbps 5.5 Mbps 11 Mbps Operating frequency [GHz] 2.412 2.442 2.462 2.412 2.442 2.462 2.412 2.442 2.462 Power meter reading [dBm] 14.6 14.9 14.9 14.7 15.0 15.0 14.6 14.9 14.9 Correctionfactor [dB] 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Output power [dBm] 15.1 15.4 15.4 15.2 15.5 15.5 15.1 15.4 15.4 Limit [dBm] 30 30 30 30 30 30 30 30 30 Result: The limit is kept Test Report No. 56305-90389-1 / Page 24 of 81 Pages Radiated Emission Test 30 MHz - 300 MHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HK 116 55 50 45 40 35 30 25 20 15 10 30 Result: Prescan 100 Project file: 56305-90389-1 300 MHz Page 25 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 300 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HL 223 55 50 45 40 35 30 25 20 15 10 300 Result: Prescan Project file: 56305-90389-1 1000 MHz Page 26 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 300 MHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HK 116 55 50 45 40 35 30 25 20 15 10 30 Result: Prescan 100 Project file: 56305-90389-1 300 MHz Page 27 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 300 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HL 223 55 50 45 40 35 30 25 20 15 10 300 Result: Prescan Project file: 56305-90389-1 1000 MHz Page 28 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak dBµV/m 70 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: Selected by hand Limit1: FCC Subpart C Transducer: HK116 / HL223 (3 m) 65 60 55 50 45 40 35 30 25 20 15 10 5 0 30 Result: Limit kept 100 Project file: 56305-90389-1 1000 MHz Page 29 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: Selected by hand Frequency MHz 34.6 40.9 45.6 50.4 54.0 55.1 56.6 57.3 58.2 59.8 61.4 63.0 64.5 66.1 70.9 100.3 109.3 112.2 114.6 116.5 191.5 200.5 205.9 214.8 225.5 300.7 335.2 383.1 401.0 426.1 451.1 476.2 501.2 630.1 660.0 690.1 Reading dBµV 10.0 13.0 9.5 17.5 14.0 21.5 16.0 14.0 16.5 21.0 21.5 19.5 18.0 20.0 17.5 27.0 19.5 17.0 18.0 17.0 17.0 20.0 13.0 20.5 12.5 18.5 12.5 13.5 17.5 11.0 17.5 10.0 9.0 8.5 6.0 6.5 Correction factor dB 13.6 12.2 11.4 10.7 10.5 10.5 10.4 10.4 10.3 10.2 10.2 10.2 10.2 10.2 10.2 11.5 12.3 12.6 12.8 12.9 16.8 17.1 17.3 17.6 17.9 16.8 18.2 19.9 20.4 21.1 21.7 22.3 22.9 25.8 26.6 27.4 Value dBµV/m 23.6 25.2 20.9 28.2 24.5 32.0 26.4 24.4 26.8 31.2 31.7 29.7 28.2 30.2 27.7 38.5 31.8 29.6 30.8 29.9 33.8 37.1 30.3 38.1 30.4 35.3 30.7 33.4 37.9 32.1 39.2 32.3 31.9 34.3 32.6 33.9 Limit dBµV/m 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 30 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: Selected by hand Frequency MHz 704.0 780.1 902.0 Reading dBµV 4.5 4.5 1.5 Correction factor dB 27.7 28.4 30.6 Value dBµV/m 32.2 32.9 32.1 Limit dBµV/m 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 31 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak dBµV/m 70 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: Selected by hand Limit1: FCC Subpart C Transducer: HK116 / HL223 (3 m) 65 60 55 50 45 40 35 30 25 20 15 10 5 0 30 Result: Limit kept 100 Project file: 56305-90389-1 1000 MHz Page 32 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz List of values: Selected by hand Frequency MHz 31.3 34.6 42.0 47.1 48.0 55.1 58.0 59.8 60.0 70.9 75.6 100.3 116.5 121.2 167.6 200.5 214.8 225.5 300.7 335.2 383.1 401.0 426.0 451.1 476.2 501.2 570.1 630.1 660.0 690.1 704.0 720.1 750.1 780.1 Reading dBµV 15.5 17.5 18.0 14.0 16.5 16.5 16.5 18.0 17.0 16.0 14.5 23.5 15.5 15.5 13.0 17.0 18.5 13.0 16.0 13.0 11.5 13.0 10.0 15.0 10.0 10.5 9.0 10.5 4.5 6.5 6.0 4.5 6.5 4.5 Correction factor dB 14.4 13.6 12.0 11.2 11.0 10.5 10.3 10.2 10.2 10.2 10.2 11.5 12.9 13.3 15.8 17.1 17.6 17.9 16.8 18.2 19.9 20.4 21.1 21.7 22.3 22.9 24.4 25.8 26.6 27.4 27.7 27.8 28.1 28.4 Value dBµV/m 29.9 31.1 30.0 25.2 27.5 27.0 26.8 28.2 27.2 26.2 24.7 35.0 28.4 28.8 28.8 34.1 36.1 30.9 32.8 31.2 31.4 33.4 31.1 36.7 32.3 33.4 33.4 36.3 31.1 33.9 33.7 32.3 34.6 32.9 Limit dBµV/m 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 33 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 300 MHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HK 116 55 50 45 40 35 30 25 20 15 10 30 Result: Prescan 100 Project file: 56305-90389-1 300 MHz Page 34 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 300 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HL 223 55 50 45 40 35 30 25 20 15 10 300 Result: Prescan Project file: 56305-90389-1 1000 MHz Page 35 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 300 MHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HK 116 55 50 45 40 35 30 25 20 15 10 30 Result: Prescan 100 Project file: 56305-90389-1 300 MHz Page 36 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 300 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HL 223 55 50 45 40 35 30 25 20 15 10 300 Result: Prescan Project file: 56305-90389-1 1000 MHz Page 37 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak dBµV/m 70 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: Selected by hand Limit1: FCC Subpart C Transducer: HK116 / HL223 (3 m) 65 60 55 50 45 40 35 30 25 20 15 10 5 0 30 Result: Limit kept 100 Project file: 56305-90389-1 1000 MHz Page 38 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: Selected by hand Frequency MHz 34.6 40.9 45.6 50.4 54.0 55.1 56.6 57.3 58.2 59.8 61.4 63.0 64.5 66.1 70.9 100.3 109.3 112.2 114.6 116.5 191.5 200.5 205.9 214.8 225.5 300.7 335.2 383.1 401.0 426.1 451.1 476.2 501.2 630.1 660.0 690.1 Reading dBµV 9.5 13.0 9.0 17.5 14.0 21.5 15.5 14.0 16.5 21.5 21.5 19.0 18.0 20.0 17.5 27.0 19.5 17.0 18.0 17.5 17.0 20.0 13.0 20.5 12.0 18.5 12.5 13.0 17.5 11.0 17.5 10.0 9.0 8.5 5.5 6.5 Correction factor dB 13.6 12.2 11.4 10.7 10.5 10.5 10.4 10.4 10.3 10.2 10.2 10.2 10.2 10.2 10.2 11.5 12.3 12.6 12.8 12.9 16.8 17.1 17.3 17.6 17.9 16.8 18.2 19.9 20.4 21.1 21.7 22.3 22.9 25.8 26.6 27.4 Value dBµV/m 23.1 25.2 20.4 28.2 24.5 32.0 25.9 24.4 26.8 31.7 31.7 29.2 28.2 30.2 27.7 38.5 31.8 29.6 30.8 30.4 33.8 37.1 30.3 38.1 29.9 35.3 30.7 32.9 37.9 32.1 39.2 32.3 31.9 34.3 32.1 33.9 Limit dBµV/m 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 39 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: Selected by hand Frequency MHz 704.0 780.1 902.0 Reading dBµV 4.5 4.5 1.5 Correction factor dB 27.7 28.4 30.6 Value dBµV/m 32.2 32.9 32.1 Limit dBµV/m 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 40 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak dBµV/m 70 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: Selected by hand Limit1: FCC Subpart C Transducer: HK116 / HL223 (3 m) 65 60 55 50 45 40 35 30 25 20 15 10 5 0 30 Result: Limit kept 100 Project file: 56305-90389-1 1000 MHz Page 41 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz List of values: Selected by hand Frequency MHz 31.3 34.6 42.0 47.1 48.0 55.1 58.0 59.8 60.0 70.9 75.6 100.3 116.5 121.2 167.6 200.5 214.8 225.5 300.7 335.2 383.1 401.0 426.0 451.1 476.2 501.2 570.1 630.1 660.0 690.1 704.0 720.1 750.1 780.1 Reading dBµV 15.0 17.5 18.0 13.5 16.5 16.5 16.5 18.0 17.5 16.0 14.5 23.5 15.0 15.5 13.0 17.0 18.5 13.0 16.0 13.0 11.5 13.0 10.0 15.0 10.0 10.0 8.5 10.5 4.5 6.5 6.0 4.5 6.5 4.5 Correction factor dB 14.4 13.6 12.0 11.2 11.0 10.5 10.3 10.2 10.2 10.2 10.2 11.5 12.9 13.3 15.8 17.1 17.6 17.9 16.8 18.2 19.9 20.4 21.1 21.7 22.3 22.9 24.4 25.8 26.6 27.4 27.7 27.8 28.1 28.4 Value dBµV/m 29.4 31.1 30.0 24.7 27.5 27.0 26.8 28.2 27.7 26.2 24.7 35.0 27.9 28.8 28.8 34.1 36.1 30.9 32.8 31.2 31.4 33.4 31.1 36.7 32.3 32.9 32.9 36.3 31.1 33.9 33.7 32.3 34.6 32.9 Limit dBµV/m 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 42 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 300 MHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HK 116 55 50 45 40 35 30 25 20 15 10 30 Result: Prescan 100 Project file: 56305-90389-1 300 MHz Page 43 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 300 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HL 223 55 50 45 40 35 30 25 20 15 10 300 Result: Prescan Project file: 56305-90389-1 1000 MHz Page 44 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 300 MHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HK 116 55 50 45 40 35 30 25 20 15 10 30 Result: Prescan 100 Project file: 56305-90389-1 300 MHz Page 45 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 300 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HL 223 55 50 45 40 35 30 25 20 15 10 300 Result: Prescan Project file: 56305-90389-1 1000 MHz Page 46 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak dBµV/m 70 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: Selected by hand Limit1: FCC Subpart C Transducer: HK116 / HL223 (3 m) 65 60 55 50 45 40 35 30 25 20 15 10 5 0 30 Result: Limit kept 100 Project file: 56305-90389-1 1000 MHz Page 47 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: Selected by hand Frequency MHz 34.6 40.9 45.6 50.4 54.0 55.1 56.6 57.3 58.2 59.8 61.4 63.0 64.5 66.1 70.9 100.3 109.3 112.2 114.6 116.5 191.5 200.5 205.9 214.8 225.5 300.7 335.2 383.1 401.0 426.1 451.1 476.2 501.2 630.1 660.0 690.1 Reading dBµV 9.5 13.0 9.5 17.5 14.0 21.5 15.0 14.0 16.5 21.5 21.5 19.5 18.0 20.0 17.0 27.0 19.5 17.0 18.0 17.5 17.5 20.0 13.0 20.5 12.5 18.5 12.5 13.0 17.5 12.0 17.5 10.0 9.0 8.5 6.0 6.5 Correction factor dB 13.6 12.2 11.4 10.7 10.5 10.5 10.4 10.4 10.3 10.2 10.2 10.2 10.2 10.2 10.2 11.5 12.3 12.6 12.8 12.9 16.8 17.1 17.3 17.6 17.9 16.8 18.2 19.9 20.4 21.1 21.7 22.3 22.9 25.8 26.6 27.4 Value dBµV/m 23.1 25.2 20.9 28.2 24.5 32.0 25.4 24.4 26.8 31.7 31.7 29.7 28.2 30.2 27.2 38.5 31.8 29.6 30.8 30.4 34.3 37.1 30.3 38.1 30.4 35.3 30.7 32.9 37.9 33.1 39.2 32.3 31.9 34.3 32.6 33.9 Limit dBµV/m 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 48 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: Selected by hand Frequency MHz 704.0 780.1 902.0 Reading dBµV 4.5 4.5 1.5 Correction factor dB 27.7 28.4 30.6 Value dBµV/m 32.2 32.9 32.1 Limit dBµV/m 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 49 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak dBµV/m 70 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: Selected by hand Limit1: FCC Subpart C Transducer: HK116 / HL223 (3 m) 65 60 55 50 45 40 35 30 25 20 15 10 5 0 30 Result: Limit kept 100 Project file: 56305-90389-1 1000 MHz Page 50 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz List of values: Selected by hand Frequency MHz 31.3 34.6 42.0 47.1 48.0 55.1 58.0 59.8 60.0 70.9 75.6 100.3 116.5 121.2 167.6 200.5 214.8 225.5 300.7 335.2 383.1 401.0 426.0 451.1 476.2 501.2 570.1 630.1 660.0 690.1 704.0 720.1 750.1 780.1 Reading dBµV 15.0 17.5 18.0 14.0 16.5 17.0 16.5 18.0 17.5 15.5 14.5 23.5 15.0 15.5 13.0 17.0 18.5 13.0 16.0 14.0 11.5 13.0 10.0 14.5 10.0 11.0 8.5 10.5 4.5 6.5 6.0 4.5 6.5 5.0 Correction factor dB 14.4 13.6 12.0 11.2 11.0 10.5 10.3 10.2 10.2 10.2 10.2 11.5 12.9 13.3 15.8 17.1 17.6 17.9 16.8 18.2 19.9 20.4 21.1 21.7 22.3 22.9 24.4 25.8 26.6 27.4 27.7 27.8 28.1 28.4 Value dBµV/m 29.4 31.1 30.0 25.2 27.5 27.5 26.8 28.2 27.7 25.7 24.7 35.0 27.9 28.8 28.8 34.1 36.1 30.9 32.8 32.2 31.4 33.4 31.1 36.2 32.3 33.9 32.9 36.3 31.1 33.9 33.7 32.3 34.6 33.4 Limit dBµV/m 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 51 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 EMV-Prüfzentrum EMI/EMC-Testcenter Radiated Emission 1 GHz - 25 GHz according to FCC Part 15 Subpart C Model: Type: Serial No.: Applicant: Test-site: Test distance: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 92290006 Lucent Technologies Nederland B.V. Semi anechoic room 3 meters 06/22/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz Detector: Peak Frequency [GHz] 2.3900 2.3987 2.4000 2.4020 2.4118 2.4228 2.5020 4.1273 4.8282 Analyzer- Generator- Polarization reading level [dBµV] [dBm] vertical 52.6 vertical 70.5 vertical 68.5 vertical 73.1 vertical 107.3 vertical 73.4 vertical 48.1 vertical 39.1 -95.0 vertical 45.2 -89.4 Cable loss [dB] 0.6 0.6 0.6 0.6 0.6 0.6 0.6 Antenna- correction Fieldstrength Limit [dB] [dBµV/m] [dBµV/m] 20.7 52.6 74 20.7 70.5 NRB 20.7 68.5 NRB 20.7 73.1 OB 20.7 107.3 OB 20.7 73.4 OB 20.7 48.1 74 27.2 39.2 74 27.3 44.9 74 Note: OB means "operation band" (2400 - 2483.5 MHz); in this case limit is 1 W (measured conducted with power meter). NRB means "non restricted band"; in this case limit is 20 dB below maximum in-band-power equivalent to 107.3 dBµV/m. Result: The limits are kept Test Report No. 56305-90389-1 / Page 52 of 81 Pages Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz Test distance: 3 meters Channel A (red) = horizontal polarization ATT 5 dB Ref. Offset 21.3 dB 5 4 6 2 3 1 Start 2.337 GHz RBW 1 MHz VBW 1 MHz Stop 2.487 GHz SWP 20 ms **** Multi Marker **** ----------------------------- Nr.1 2.390000 GHz 50.89 dBµV/m Nr.2 2.397833 GHz 60.06 dBµV/m Nr.3 2.400000 GHz 56.88 dBµV/m Nr.4 2.403333 GHz 73.29 dBµV/m Nr.5 2.413667 GHz 94.59 dBµV/m Nr.6 2.421000 GHz 72.63 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 53 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz Test distance: 3 meters Channel B (green) = vertical polarization ATT 5 dB Ref. Offset 21.3 dB 5 4 6 2 3 1 Start 2.337 GHz RBW 1 MHz VBW 1 MHz Stop 2.487 GHz SWP 20 ms **** Multi Marker **** ----------------------------- Nr.1 2.390000 GHz 52.56 dBµV/m Nr.2 2.398667 GHz 70.54 dBµV/m Nr.3 2.400000 GHz 68.49 dBµV/m Nr.4 2.402000 GHz 73.13 dBµV/m Nr.5 2.411833 GHz 107.26 dBµV/m Nr.6 2.422833 GHz 73.36 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 54 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 EMV-Prüfzentrum EMI/EMC-Testcenter Radiated Emission 1 GHz - 25 GHz according to FCC Part 15 Subpart C Model: Type: Serial No.: Applicant: Test-site: Test distance: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 92290006 Lucent Technologies Nederland B.V. Semi anechoic room 3 meters 06/22/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz Detector: Average Frequency [GHz] 2.3900 2.3930 2.3988 2.4000 2.4148 2.4305 2.5001 4.8241 Analyzer- Generator- Polarization reading level [dBµV] [dBm] vertical 42.5 vertical 53.9 vertical 62.4 vertical 60.6 vertical 104.0 vertical 53.8 vertical 45.2 vertical 42.0 -92.4 Cable loss [dB] 0.6 0.6 0.6 0.6 0.6 0.6 0.6 Antenna- correction Fieldstrength Limit [dB] [dBµV/m] [dBµV/m] 20.7 42.5 54 20.7 53.9 NRB 20.7 62.4 NRB 20.7 60.6 NRB 20.7 104.0 OB 20.7 53.8 OB 20.7 45.2 54 27.3 41.9 54 Note: OB means "operation band" (2400 - 2483.5 MHz); in this case limit is 1 W (measured conducted with power meter). NRB means "non restricted band"; in this case limit is 20 dB below maximum in-band-power equivalent to 104.0 dBµV/m. Result: The limits are kept Test Report No. 56305-90389-1 / Page 55 of 81 Pages Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz Test distance: 3 meters Channel A (red) = horizontal polarization ATT 5 dB Ref. Offset 21.3 dB 5 4 6 2 3 1 Start 2.337 GHz RBW 1 MHz VBW 100 Hz Stop 2.487 GHz SWP 4.60 s **** Multi Marker **** ----------------------------- Nr.1 2.390000 GHz 39.08 dBµV/m Nr.2 2.398667 GHz 48.17 dBµV/m Nr.3 2.400000 GHz 46.85 dBµV/m Nr.4 2.401667 GHz 52.62 dBµV/m Nr.5 2.413500 GHz 87.63 dBµV/m Nr.6 2.422000 GHz 53.43 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 56 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.412 GHz Test distance: 3 meters Channel B (green) = vertical polarization ATT 5 dB Ref. Offset 21.3 dB 5 3 4 2 6 1 Start 2.337 GHz RBW 1 MHz VBW 100 Hz Stop 2.487 GHz SWP 4.60 s **** Multi Marker **** ----------------------------- Nr.1 2.390000 GHz 42.53 dBµV/m Nr.2 2.393000 GHz 53.89 dBµV/m Nr.3 2.398833 GHz 62.42 dBµV/m Nr.4 2.400000 GHz 60.59 dBµV/m Nr.5 2.414833 GHz 103.99 dBµV/m Nr.6 2.430500 GHz 53.78 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 57 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 EMV-Prüfzentrum EMI/EMC-Testcenter Radiated Emission 1 GHz - 25 GHz according to FCC Part 15 Subpart C Model: Type: Serial No.: Applicant: Test-site: Test distance: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 92290006 Lucent Technologies Nederland B.V. Semi anechoic room 3 meters 06/22/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz Detector: Peak Frequency [GHz] 2.4320 2.4417 2.4530 2.4880 2.5320 4.1843 4.8894 7.3279 Analyzer- Generator- Polarization reading level [dBµV] [dBm] vertical 74.0 vertical 107.4 vertical 73.2 vertical 44.0 vertical 44.3 vertical 40.0 -94.2 vertical 47.8 -86.6 vertical 42.9 -93.8 Cable loss [dB] 0.6 0.6 0.6 0.6 0.6 Antenna- correction Fieldstrength Limit [dB] [dBµV/m] [dBµV/m] 20.7 74.0 OB 20.7 107.4 OB 20.7 73.2 OB 20.7 44.0 74 20.7 44.3 74 27.2 40.0 74 27.3 47.7 74 29.9 43.1 74 Note: OB means "operation band" (2400 - 2483.5 MHz); in this case limit is 1 W (measured conducted with power meter). NRB means "non restricted band"; in this case limit is 20 dB below maximum in-band-power equivalent to 107.4 dBµV/m. Result: The limits are kept Test Report No. 56305-90389-1 / Page 58 of 81 Pages Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz Test distance: 3 meters Channel A (red) = horizontal polarization ATT 5 dB Ref. Offset 21.3 dB 3 2 1 4 5 Start 2.367 GHz RBW 1 MHz VBW 1 MHz Stop 2.517 GHz SWP 20 ms **** Multi Marker **** ----------------------------- Nr.1 2.428167 GHz 62.72 dBµV/m Nr.2 2.433333 GHz 73.92 dBµV/m Nr.3 2.441667 GHz 94.69 dBµV/m Nr.4 2.451000 GHz 73.06 dBµV/m Nr.5 2.454667 GHz 58.81 dBµV/m Nr.6 Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 59 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz Test distance: 3 meters Channel B (green) = vertical polarization ATT 5 dB Ref. Offset 21.3 dB 3 1 2 4 5 Start 2.367 GHz RBW 1 MHz VBW 1 MHz Stop 2.517 GHz SWP 20 ms **** Multi Marker **** ----------------------------- Nr.1 2.427833 GHz 71.99 dBµV/m Nr.2 2.432000 GHz 73.97 dBµV/m Nr.3 2.441667 GHz 107.41 dBµV/m Nr.4 2.453000 GHz 73.24 dBµV/m Nr.5 2.455500 GHz 70.77 dBµV/m Nr.6 Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 60 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 EMV-Prüfzentrum EMI/EMC-Testcenter Radiated Emission 1 GHz - 25 GHz according to FCC Part 15 Subpart C Model: Type: Serial No.: Applicant: Test-site: Test distance: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 92290006 Lucent Technologies Nederland B.V. Semi anechoic room 3 meters 06/22/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz Detector: Average Frequency [GHz] 2.4233 2.4448 2.4605 2.4862 4.8841 Analyzer- Generator- Polarization reading level [dBµV] [dBm] vertical 53.9 vertical 103.8 vertical 53.8 vertical 42.4 vertical 44.7 -89.5 Cable loss [dB] 0.6 0.6 0.6 0.6 Antenna- correction Fieldstrength Limit [dB] [dBµV/m] [dBµV/m] 20.7 53.9 OB 20.7 103.8 OB 20.7 53.8 OB 20.7 42.4 54 27.3 44.8 54 Note: Result: OB means "operation band" (2400 - 2483.5 MHz); in this case limit is 1 W (measured conducted with power meter). NRB means "non restricted band"; in this case limit is 20 dB below maximum in-band-power equivalent to 103.8 dBµV/m. The limits are kept Test Report No. 56305-90389-1 / Page 61 of 81 Pages Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz Test distance: 3 meters Channel A (red) = horizontal polarization ATT 5 dB Ref. Offset 21.3 dB 3 1 2 4 5 Start 2.367 GHz RBW 1 MHz VBW 100 Hz Stop 2.517 GHz SWP 4.60 s **** Multi Marker **** ----------------------------- Nr.1 2.428833 GHz 51.27 dBµV/m Nr.2 2.431500 GHz 53.43 dBµV/m Nr.3 2.443500 GHz 87.99 dBµV/m Nr.4 2.452000 GHz 53.81 dBµV/m Nr.5 2.454667 GHz 47.99 dBµV/m Nr.6 Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 62 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.442 GHz Test distance: 3 meters Channel B (green) = vertical polarization ATT 5 dB Ref. Offset 21.3 dB 3 2 1 4 5 6 Start 2.367 GHz RBW 1 MHz VBW 100 Hz Stop 2.517 GHz SWP 4.60 s **** Multi Marker **** ----------------------------- Nr.1 2.423333 GHz 53.94 dBµV/m Nr.2 2.428833 GHz 63.15 dBµV/m Nr.3 2.444833 GHz 103.81 dBµV/m Nr.4 2.454500 GHz 63.89 dBµV/m Nr.5 2.460500 GHz 53.78 dBµV/m Nr.6 2.486167 GHz 42.36 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 63 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 EMV-Prüfzentrum EMI/EMC-Testcenter Radiated Emission 1 GHz - 25 GHz according to FCC Part 15 Subpart C Model: Type: Serial No.: Applicant: Test-site: Test distance: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 92290006 Lucent Technologies Nederland B.V. Semi anechoic room 3 meters 06/22/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz Detector: Peak Frequency [GHz] 2.4518 2.4618 2.4730 2.4835 2.4872 2.5000 2.5080 4.9296 7.3932 Analyzer- Generator- Polarization reading level [dBµV] [dBm] vertical 72.1 vertical 108.1 vertical 73.2 vertical 55.1 vertical 56.8 vertical 52.1 vertical 44.1 vertical 45.3 -89.1 vertical 41.1 -95.0 Cable loss [dB] 0.6 0.6 0.6 0.6 0.6 0.6 0.6 Antenna- correction Fieldstrength Limit [dB] [dBµV/m] [dBµV/m] 20.7 72.1 OB 20.7 108.1 OB 20.7 73.2 OB 20.7 55.1 74 20.7 56.8 74 20.7 52.1 74 20.7 44.1 NRB 27.3 45.2 74 30.0 41.9 74 Note: OB means "operation band" (2400 - 2483.5 MHz); in this case limit is 1 W (measured conducted with power meter). NRB means "non restricted band"; in this case limit is 20 dB below maximum in-band-power equivalent to 108.1 dBµV/m. Result: The limits are kept Test Report No. 56305-90389-1 / Page 64 of 81 Pages Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz Test distance: 3 meters Channel A (red) = horizontal polarization ATT 5 dB Ref. Offset 21.3 dB 2 1 3 4 5 6 Start 2.387 GHz RBW 1 MHz VBW 1 MHz Stop 2.537 GHz SWP 20 ms **** Multi Marker **** ----------------------------- Nr.1 2.453500 GHz 73.67 dBµV/m Nr.2 2.463333 GHz 93.98 dBµV/m Nr.3 2.470833 GHz 73.84 dBµV/m Nr.4 2.483500 GHz 51.45 dBµV/m Nr.5 2.497667 GHz 51.85 dBµV/m Nr.6 2.500000 GHz 49.26 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 65 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz Test distance: 3 meters Channel B (green) = vertical polarization ATT 5 dB Ref. Offset 21.3 dB 2 1 3 4 5 6 Start 2.387 GHz RBW 1 MHz VBW 1 MHz Stop 2.537 GHz SWP 20 ms **** Multi Marker **** ----------------------------- Nr.1 2.451833 GHz 72.07 dBµV/m Nr.2 2.461833 GHz 108.05 dBµV/m Nr.3 2.473000 GHz 73.16 dBµV/m Nr.4 2.483500 GHz 55.05 dBµV/m Nr.5 2.487167 GHz 56.78 dBµV/m Nr.6 2.500000 GHz 52.13 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 66 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 EMV-Prüfzentrum EMI/EMC-Testcenter Radiated Emission 1 GHz - 25 GHz according to FCC Part 15 Subpart C Model: Type: Serial No.: Applicant: Test-site: Test distance: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 92290006 Lucent Technologies Nederland B.V. Semi anechoic room 3 meters 06/22/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz Detector: Average Frequency [GHz] 2.4427 2.4648 2.4800 2.4835 2.4840 2.5000 4.9242 Analyzer- Generator- Polarization reading level [dBµV] [dBm] vertical 53.1 vertical 102.9 vertical 53.9 vertical 43.0 vertical 43.5 vertical 40.2 vertical 40.9 -93.3 Cable loss [dB] 0.6 0.6 0.6 0.6 0.6 0.6 Antenna- correction Fieldstrength Limit [dB] [dBµV/m] [dBµV/m] 20.7 53.1 OB 20.7 102.9 OB 20.7 53.9 OB 20.7 43.0 54 20.7 43.5 54 20.7 40.2 54 27.3 41.0 54 Note: Result: OB means "operation band" (2400 - 2483.5 MHz); in this case limit is 1 W (measured conducted with power meter). NRB means "non restricted band"; in this case limit is 20 dB below maximum in-band-power equivalent to 102.9 dBµV/m. The limits are kept Test Report No. 56305-90389-1 / Page 67 of 81 Pages Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz Test distance: 3 meters Channel A (red) = horizontal polarization ATT 5 dB Ref. Offset 21.3 dB 2 1 3 4 5 6 Start 2.387 GHz RBW 1 MHz VBW 100 Hz Stop 2.537 GHz SWP 4.60 s **** Multi Marker **** ----------------------------- Nr.1 2.451667 GHz 52.79 dBµV/m Nr.2 2.463333 GHz 86.34 dBµV/m Nr.3 2.472000 GHz 53.56 dBµV/m Nr.4 2.483500 GHz 38.80 dBµV/m Nr.5 2.483667 GHz 38.88 dBµV/m Nr.6 2.500000 GHz 38.88 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 68 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 Radiated emission 1 GHz - 25 GHz acc. to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial No.: 92290006 Applicant: Lucent Technologies Nederland B.V. Ref.Level 120 dBµV/m 10 dB dB/Div. Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - operating with bit rate 11 Mbps - TX mode with f = 2.462 GHz Test distance: 3 meters Channel B (green) = vertical polarization ATT 5 dB Ref. Offset 21.3 dB 2 1 3 4 5 6 Start 2.387 GHz RBW 1 MHz VBW 100 Hz Stop 2.537 GHz SWP 4.60 s **** Multi Marker **** ----------------------------- Nr.1 2.442667 GHz 53.07 dBµV/m Nr.2 2.464833 GHz 102.89 dBµV/m Nr.3 2.480000 GHz 53.94 dBµV/m Nr.4 2.483500 GHz 43.04 dBµV/m Nr.5 2.484000 GHz 43.47 dBµV/m Nr.6 2.500000 GHz 40.22 dBµV/m Nr.7 Nr.8 Tested by: Rainer Heller Date: 06/22/1999 Project-No.: 56305-90389-1 Page 69 of 81 Pages Senton GmbH / EMV-Prüfzentrum / Äußere Frühlingstraße 45 / 94315 Straubing / Tel. 09421 55220 EMV-Prüfzentrum EMI/EMC-Testcenter Test results for Receive (RX) mode FCC-ID: IMRWLPC24H Page 70 of 81 Pages Test Report No. 56305-90389-1 Radiated Emission Test 30 MHz - 300 MHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HK 116 55 50 45 40 35 30 25 20 15 10 30 Result: Prescan 100 Project file: 56305-90389-1 300 MHz Page 71 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 300 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HL 223 55 50 45 40 35 30 25 20 15 10 300 Result: Prescan Project file: 56305-90389-1 1000 MHz Page 72 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 300 MHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HK 116 55 50 45 40 35 30 25 20 15 10 30 Result: Prescan 100 Project file: 56305-90389-1 300 MHz Page 73 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 300 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/16/1999 Operator: R. Heller Test performed: automatically File name: Detector: Peak dBµV/m 60 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: 10 dB Margin 50 Subranges Limit1: FCC Subpart C Transducer: HL 223 55 50 45 40 35 30 25 20 15 10 300 Result: Prescan Project file: 56305-90389-1 1000 MHz Page 74 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak dBµV/m 70 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: Selected by hand Limit1: FCC Subpart C Transducer: HK116 / HL223 (3 m) 65 60 55 50 45 40 35 30 25 20 15 10 5 0 30 Result: Limit kept 100 Project file: 56305-90389-1 1000 MHz Page 75 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: Selected by hand Frequency MHz 34.6 40.9 45.6 50.4 54.0 55.1 56.6 57.3 58.2 59.8 61.4 63.0 64.5 66.1 70.9 100.3 109.3 112.2 114.6 116.5 191.5 200.5 205.9 214.8 225.5 300.7 335.2 383.1 401.0 426.1 451.1 476.2 501.2 630.1 660.0 690.1 Reading dBµV 9.5 13.0 10.0 17.5 14.0 21.5 15.5 14.5 16.5 21.5 21.5 19.0 18.0 20.0 17.5 27.0 19.5 17.5 18.0 17.5 17.0 20.0 13.0 20.5 12.0 18.5 13.0 13.0 17.5 11.5 17.5 10.0 9.0 8.5 5.5 6.5 Correction factor dB 13.6 12.2 11.4 10.7 10.5 10.5 10.4 10.4 10.3 10.2 10.2 10.2 10.2 10.2 10.2 11.5 12.3 12.6 12.8 12.9 16.8 17.1 17.3 17.6 17.9 16.8 18.2 19.9 20.4 21.1 21.7 22.3 22.9 25.8 26.6 27.4 Value dBµV/m 23.1 25.2 21.4 28.2 24.5 32.0 25.9 24.9 26.8 31.7 31.7 29.2 28.2 30.2 27.7 38.5 31.8 30.1 30.8 30.4 33.8 37.1 30.3 38.1 29.9 35.3 31.2 32.9 37.9 32.6 39.2 32.3 31.9 34.3 32.1 33.9 Limit dBµV/m 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 76 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Horizontal Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: Selected by hand Frequency MHz 780.1 902.0 Reading dBµV 5.0 1.5 Correction factor dB 28.4 30.6 Value dBµV/m 33.4 32.1 Limit dBµV/m 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 77 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak dBµV/m 70 Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: Selected by hand Limit1: FCC Subpart C Transducer: HK116 / HL223 (3 m) 65 60 55 50 45 40 35 30 25 20 15 10 5 0 30 Result: Limit kept 100 Project file: 56305-90389-1 1000 MHz Page 78 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Emission Test 30 MHz - 1 GHz according to FCC Part 15 Subpart C Model: LUC PC24-H-FC Serial no.: 92290006 Applicant: Lucent Technologies Nederland B.V. Test site: Open area test-site I Tested on: Test distance 3 meters Vertical Polarization Date of test: 06/17/1999 Operator: R. Heller Test performed: by hand File name: Detector: Quasi-Peak Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-0202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz List of values: Selected by hand Frequency MHz 31.3 34.6 42.0 47.1 48.0 55.1 58.0 59.8 60.0 70.9 75.6 100.3 116.5 121.2 167.6 200.5 214.8 225.5 300.7 335.2 383.1 401.0 426.0 451.1 476.2 501.2 570.1 630.1 660.0 690.1 720.1 750.1 780.1 Reading dBµV 15.0 17.5 17.5 13.5 16.5 16.5 16.0 18.0 17.5 15.0 14.5 23.5 15.0 15.5 13.0 17.0 18.5 13.0 16.0 13.0 11.5 13.0 10.0 15.0 10.0 10.5 8.5 10.5 4.5 6.5 5.0 6.5 4.5 Correction factor dB 14.4 13.6 12.0 11.2 11.0 10.5 10.3 10.2 10.2 10.2 10.2 11.5 12.9 13.3 15.8 17.1 17.6 17.9 16.8 18.2 19.9 20.4 21.1 21.7 22.3 22.9 24.4 25.8 26.6 27.4 27.8 28.1 28.4 Value dBµV/m 29.4 31.1 29.5 24.7 27.5 27.0 26.3 28.2 27.7 25.2 24.7 35.0 27.9 28.8 28.8 34.1 36.1 30.9 32.8 31.2 31.4 33.4 31.1 36.7 32.3 33.4 32.9 36.3 31.1 33.9 32.8 34.6 32.9 Limit dBµV/m 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Limit exceeded Result: Limit kept Project file: 56305-90389-1 Page 79 of 81 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 EMV-Prüfzentrum EMI/EMC-Testcenter Radiated Emission 1 GHz - 12.5 GHz according to FCC Part 15 Subpart C Model: Type: Serial No.: Applicant: Test-site: Test distance: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 92290006 Lucent Technologies Nederland B.V. Semi anechoic room 3 meters 06/22/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz Detector: Peak Frequency [GHz] 1.000 -12.500 Polarization Analyzerreading [dBµV] Generatorlevel [dBm] Cable loss [dB] Antenna- correction Fieldstrength Limit [dB] [dBµV/m] [dBµV/m] 74 Note: No levels above noise floor detected Test Report No. 56305-90389-1 / Page 80 of 81 Pages EMV-Prüfzentrum EMI/EMC-Testcenter Radiated Emission 1 GHz - 12.5 GHz according to FCC Part 15 Subpart C Model: Type: Serial No.: Applicant: Test-site: Test distance: Date of test: Operator: LUC PC24-H-FC RF-modem for wireless LAN 92290006 Lucent Technologies Nederland B.V. Semi anechoic room 3 meters 06/22/1999 R. Heller Mode: - RF-modem PC24-H-FC mounted in AT & T Globalyst 200 - FCC test setup - supply voltage 115 V AC - with external antenna AIN24-OD-202 (1.5 m antenna cable) - RX mode with f = 2.442 GHz Detector: Average Frequency [GHz] 1.000 -12.500 Polarization Analyzerreading [dBµV] Generatorlevel [dBm] Cable loss [dB] Antenna- correction Fieldstrength Limit [dB] [dBµV/m] [dBµV/m] 54 Note: No levels above noise floor detected Test Report No. 56305-90389-1 / Page 81 of 81 PagesAcrobat Distiller 3.01 for Windows ADOBEPS4.DRV Version 4.11