First Co. UC Series Wall Mount Fan Coils
Product Overview and Specifications
Introduction
The First Co. UC Series offers a range of wall mount fan coils designed as upflow indoor air handlers for use with split-system heat pumps or condensing units. These units are compatible with R410A refrigerant and are intended for servicing existing equipment. They provide efficient cooling or heating capabilities, with options for electric heat up to 10 kW or hydronic heating.
Key features include galvanized steel cabinets, insulated construction, sloped condensate pans for proper drainage, and removable doors with captive screws for easy service access. Drain piping flexibility is offered, allowing connections from the bottom, front, left, or right side.
The series includes models such as UCO (Electric Heat w/PSC Motor), UCX (Electric Heat w/ECM Motor), UCOW (Hydronic Heat w/PSC Motor & DX Coil for Cooling), UCOQ (Hydronic Heat w/Circulator Pump & PSC Motor), UCXW (Hydronic Heat w/ECM Motor & DX Coil for Cooling), and UCXRX (Hydronic Heat w/Hi Flow Pump & ECM Motor).
Compatibility Note: First Co. customers are responsible for confirming fan coil model compatibility with selected outdoor units and required expansion valves. Certified indoor/outdoor combinations can be found at www.ahrinet.org or by contacting the factory.
Image of a First Co. UC Series Wall Mount Fan Coil unit.
Full Series Nomenclature
The model numbering system provides detailed configuration information:
Example: 25 UCX 05 X 1 0 A V 0 0 0 F
UNIT SIZE: Indicates cooling capacity (e.g., 18, 19 for 18,000 BTUH, 25 for 24,000 BTUH, 30 for 30,000 BTUH, 37 for 36,000 BTUH).
SERIES: UCO, UCX, etc.
HEAT OPTION: Specifies heating type and capacity (e.g., 00 - No Heat, 03 - 3 KW, W3 - 3 Row HW, R3 - 3 Row Hi Flow Pump HW).
MOTOR TYPE: 0 - PSC, X - ECM Multispeed.
VOLTAGE: 1 - 120/1/60, 2 - 208-230/1/60.
CABINET OPTIONS: 0 - Standard Front Return, B - Bottom Return.
BRAND: F - First Co.
OPTIONS: GENERAL: 0 - Standard, 2 - 2-Way HW Valve, 3 - 3-Way HW Valve, T - Stub Out Tubes.
OPTIONS: SENSORS/SWITCHES: 0 - None / Standard, 1 - Freeze Stat, 2 - Float Switch, 3 - Freeze Stat & Float Switch, 4 - DX Coil Sensor, 5 - DX Sensor & Freeze Stat.
OPTIONS: CONTROL: 0 - Standard, B - Standard Pump Control, T - Time Delay.
METERING DEVICE: C - Chilled Water Coil, V - Non Bleed TXV w/ Check.
REFRIGERANT: A - R410A.
UCO Series: Electric Heat w/PSC Motor
The UCO series features electric heat with a PSC motor, designed as an upflow indoor air handler.
Standard Features:
- 240V motor, 24V controls
- Factory installed disconnect with electric heat only
- Factory or field installed electric heat (on heater kit units only)
- Separate compartment for drain connections
- Drain pan with 3/4" male or female primary and secondary fittings
- High efficiency cooling coil
- Convenient equalizer connection for factory or field installed TXVs (non-bleed type)
- Easily accessible 1" filter
- Cabinet air leakage ≤ 2% (ASHRAE 193)
- Wall hanging brackets included
Optional Features:
Optional accessories include field installed Heater Kits, factory or field installed TXV Kits (non-bleed type), Wall Panels with Captive Screws, Condensate Overflow Switch, Closet Hanger Bracket Kit, and Bottom Return Air Kit.
Physical Dimensions:
| UNIT MODEL | A | B | C | D | E | F | FILTER SIZE | LIQUID LINE | SUCTION LINE |
|---|---|---|---|---|---|---|---|---|---|
| 18-25UC0 | 22-1/8 | 15-1/8 | 40 | 14 | 10.5 | 3-5/8 | 18 X 18 | 3/8 O.D. | 5/8 O.D. |
| 26/30/31UC0 | 22-1/8 | 15-1/8 | 40 | 14 | 10.5 | 3-5/8 | 18 X 20 | 3/8 O.D. | 3/4 O.D. |
| 32/37UC0 | 22-1/8 | 18-1/8 | 43 | 14 | 13 | 3-5/8 | 18 X 24 | 3/8 O.D. | 3/4 O.D. |
| 38UC0 | 28-1/8 | 21 | 46 | 16-1/2 | 13 | 7-1/2 | 24 x 24 | 3/8 O.D. | 7/8 O.D. |
Performance Data (Electric Heat w/PSC Motor):
Performance Data Tables
Electric Heat Capacity:
| UNIT MODEL | NOM. CFM | NOM. COOL BTUH | ELECTRIC HEAT CAPACITY (kW) | ELECTRIC HEAT CAPACITY (BTUH) | TOTAL AMPS | MIN. AMPACITY | MAX. OVERCURRENT PROTECTION | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 240V | 208V | 240V | 208V | 240V | 208V | 240V | 208V | 240V | 208V | ||||
| 18UC0 0-HK | 600 | 18000 | 0 | 0 | 0 | 0 | 1.70 | 1.70 | 2 | 2 | 15 | 15 | |
| 19UC0 | 3 | 2.3 | 10239 | 7781 | 14 | 12.76 | 18 | 16 | 20 | 20 | |||
| 20UC0 | 3 | 5 | 3.8 | 17065 | 12969 | 23 | 19.97 | 28 | 26 | 30 | 30 | ||
| 24UC0 | 6 | 6 | 4.5 | 20478 | 15358 | 27 | 23.34 | 33 | 29 | 35 | 30 | ||
| 25UC0 | 800 | 25000 | 8 | 6.0 | 27304 | 20750 | 35 | 30.55 | 44 | 38 | 45 | 40 | |
| 26UC0 | 8 | 10 | 7.5 | 34130 | 25597 | 43 | 37.76 | 54 | 47 | 60 | 50 | ||
| 31UC0 | 0-HK | 0 | 0 | 0 | 0 | 2.0 | 2.0 | 3 | 3 | 15 | 15 | ||
| 30UC0 | 3 | 1000 | 30000 | 3 | 2.3 | 10239 | 7781 | 15 | 15 | 18 | 16 | 20 | 20 |
| 32UC0 | 3 | 5 | 3.8 | 17065 | 12969 | 23 | 20 | 29 | 26 | 30 | 30 | ||
| 36UC0 | 6 | 6 | 4.5 | 20478 | 15358 | 27 | 24 | 34 | 30 | 35 | 30 | ||
| 37UC0 | 1200 | 36000 | 8 | 6.0 | 27304 | 20750 | 35 | 31 | 44 | 39 | 45 | 40 | |
| 38UC0 | 8 | 10 | 7.5 | 34130 | 25597 | 44 | 38 | 55 | 48 | 60 | 50 | ||
Blower Data (CFM vs. External Static Pressure):
| MODEL | MOTOR (HP) (240V) | FAN SPEED | 0.10 | 0.20 | 0.30 | 0.40 | 0.50 |
|---|---|---|---|---|---|---|---|
| 18UC0 | 1/6 | HIGH | 880 | 840 | 810 | 790 | 760 |
| 19UC0 | MEDIUM | 660 | 640 | 630 | 600 | 570 | |
| 20UC0 | LOW | 540 | 520 | 500 | 470 | 440 | |
| 24UC0 | 1/6 | HIGH | 850 | 820 | 780 | 750 | 710 |
| 25UC0 | MEDIUM | 660 | 640 | 610 | 570 | 540 | |
| 26UC0 | LOW | 540 | 520 | 500 | 470 | 430 | |
| 30UC0 | 1/6 | HIGH | 840 | 800 | 760 | 710 | 660 |
| 31UC0 | MEDIUM | 660 | 640 | 610 | 570 | 530 | |
| 32UC0 | LOW | 540 | 510 | 500 | 460 | 420 | |
| 36UC0 | 1/4 | HIGH | 870 | 840 | 810 | 780 | 750 |
| 37UC0 | MED-HIGH | 670 | 650 | 630 | 590 | 560 | |
| 38UC0 | MED-LOW | 560 | 540 | 510 | 480 | 440 | |
| LOW | 550 | 530 | 500 | 470 | 440 | ||
| 1/4 | HIGH | 1080 | 1045 | 1030 | 975 | 920 | |
| MEDIUM | 950 | 940 | 910 | 865 | 820 | ||
| LOW | 865 | 855 | 825 | 790 | 745 | ||
| 1/4 | HIGH | 910 | 880 | 840 | 790 | 740 | |
| MED-HIGH | 860 | 830 | 790 | 740 | 690 | ||
| MED-LOW | 830 | 790 | 750 | 710 | 660 | ||
| 1/4 | HIGH | 1080 | 1040 | 1000 | 950 | 900 | |
| MED-HIGH | 970 | 940 | 900 | 850 | 800 | ||
| MED-LOW | 690 | 650 | 600 | 550 | 510 | ||
| 1/2 | HIGH | 1300 | 1240 | 1180 | 1120 | 1050 | |
| MED-HIGH | 1100 | 1050 | 1010 | 960 | 910 | ||
| MED-LOW | 980 | 950 | 920 | 880 | 830 | ||
| 1/2 | HIGH | 1240 | 1180 | 1120 | 1070 | 1020 | |
| MED-HIGH | 1080 | 1040 | 1000 | 960 | 910 | ||
| MED-LOW | 980 | 950 | 910 | 870 | 820 | ||
| 1/2 | HIGH | 1430 | 1400 | 1370 | 1340 | 1290 | |
| MED-HIGH | 1260 | 1230 | 1200 | 1180 | 1160 | ||
| MED-LOW | 1000 | 990 | 980 | 970 | 950 |
Diagram showing a UC Series unit with labels for dimensions A through F, and openings for service access.
UCOW Series: Hydronic Heat w/PSC Motor & DX Coil for Cooling
The UCOW series combines hydronic heating with a PSC motor and a DX coil for cooling, suitable for use with tankless water heaters or boilers.
Features:
- Compatible with gas-fired water heaters or boilers up to 45,300 BTUH hydronic heat.
- High efficiency cooling coil.
- Accessible HW connections.
- Optional features include Wall Panels, TXV Kits, Condensate Overflow Switch, Closet Hanger Bracket Kit, and Bottom Return Air Kit.
- Unique feature for recessed wall applications: hot water coil can be removed without drywall modification.
Physical Dimensions:
| UNIT MODEL | A | B | C | D | E | FILTER SIZE | LIQUID LINE | SUCTION LINE |
|---|---|---|---|---|---|---|---|---|
| 18-25UC0W | 22-1/8 | 18 | 43 | 18 | 12-1/2 | 18 X 18 | 3/8" O.D. | 5/8" O.D. |
| 26/31UC0W | 22-1/8 | 18 | 43 | 18 | 12-1/2 | 18 X 20 | 3/8" O.D. | 3/4" O.D. |
| 32-37UC0W | 22-1/8 | 21 | 43 | 18 | 15-1/2 | 18 X 24 | 3/8" O.D. | 3/4" O.D. |
| 38UC0W | 28-1/8 | 21 | 46 | 24-1/8 | 15-3/4 | 24 X 24 | 3/8" O.D. | 7/8" O.D. |
Performance Data (Hydronic Heat w/PSC Motor & DX Coil):
Heating Performance and Electrical Data:
| UNIT MODEL | NOMINAL COOLING BTUH | P.D. (FT. WATER) (COIL ONLY) | HEATING BTUH (1000) AT ENTERING WATER TEMPERATURE (1) Delta-T 20° | MIN. CIRCUIT AMPACITY | MAX. FUSE OR HACR BREAKER | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 120°F GPM | 140°F GPM | 180°F GPM | ||||||||||
| 18-20UC0W | 18,000 | 3.3 | 19.1 | 1.9 | 26.8 | 2.7 | 42.1 | 4.2 | 8 | 15 | ||
| 2.1 | 18.5 | 1.9 | 25.9 | 2.6 | 40.7 | 4.1 | ||||||
| 1.2 | 17.6 | 1.8 | 24.6 | 2.5 | 38.7 | 3.9 | ||||||
| 24-26UC0W | 24,000 / 18,000 | 3.3 | 22.9 | 2.3 | 32.1 | 3.2 | 50.4 | 5.0 | 8 | 15 | ||
| 2.1 | 22.1 | 2.2 | 31.0 | 3.1 | 48.7 | 4.9 | ||||||
| 1.2 | 20.8 | 2.1 | 29.2 | 2.9 | 45.9 | 4.6 | ||||||
| 31UC0W | 30,000 / 24,000 | 3.3 | 26.1 | 2.6 | 36.5 | 3.7 | 57.3 | 5.7 | 11 | 15 | ||
| 2.1 | 25.0 | 2.5 | 35.1 | 3.5 | 55.1 | 5.5 | ||||||
| 1.2 | 23.5 | 2.4 | 32.9 | 3.3 | 51.7 | 5.2 | ||||||
| 32UC0W | 30,000 / 24,000 | 3.6 | 28.1 | 2.8 | 39.3 | 3.9 | 61.7 | 6.2 | 11 | 15 | ||
| 2.4 | 26.9 | 2.7 | 37.7 | 3.8 | 59.2 | 5.9 | ||||||
| 1.3 | 25.2 | 2.5 | 35.3 | 3.5 | 55.4 | 5.5 | ||||||
| 36-38UC0W | 36,000 / 30,000 | 3.6 | 30.9 | 3.1 | 43.2 | 4.3 | 67.9 | 6.8 | 11 | 15 | ||
| 2.4 | 29.6 | 3.0 | 41.3 | 4.1 | 64.9 | 6.5 | ||||||
| 1.3 | 27.5 | 2.8 | 38.5 | 3.9 | 60.5 | 6.1 | ||||||
Blower Data (CFM vs. External Static Pressure):
| UNIT MODEL | MOTOR H.P. (120V) | MOTOR AMPS (120V) | FAN SPEED | 0.10 | 0.15 | 0.20 | 0.25 | 0.30 | 0.40 | 0.50 |
|---|---|---|---|---|---|---|---|---|---|---|
| 18/19UC0W | 1/3 | 5.4 | MED-HIGH | 790 | 775 | 760 | 745 | 730 | 700 | 670 |
| MED-LOW | 710 | 695 | 680 | 665 | 650 | 630 | 610 | |||
| LOW | 560 | 550 | 540 | 525 | 510 | 490 | 460 | |||
| 20UC0W | 1/3 | 5.4 | MED-HIGH | 770 | 750 | 730 | 710 | 690 | 650 | 610 |
| MED-LOW | 690 | 675 | 660 | 645 | 630 | 590 | 550 | |||
| LOW | 540 | 525 | 510 | 495 | 480 | 450 | 420 | |||
| 24/25UC0W | 1/3 | 5.4 | HIGH | 840 | 820 | 800 | 780 | 760 | 710 | 660 |
| MED-HIGH | 770 | 750 | 730 | 710 | 690 | 650 | 610 | |||
| MED-LOW | 690 | 665 | 660 | 645 | 630 | 590 | 550 | |||
| 26UC0W | 1/3 | 5.4 | HIGH | 860 | 845 | 830 | 810 | 790 | 750 | 700 |
| MED-HIGH | 780 | 765 | 750 | 735 | 720 | 680 | 640 | |||
| MED-LOW | 700 | 685 | 670 | 655 | 640 | 600 | 560 | |||
| 31UC0W | 1/2 | 8.1 | HIGH | 1070 | 1045 | 1020 | 995 | 970 | 920 | 850 |
| MED-HIGH | 1020 | 1000 | 980 | 960 | 940 | 890 | 820 | |||
| MED-LOW | 760 | 755 | 750 | 735 | 720 | 680 | 640 | |||
| 32UC0W | 1/2 | 8.1 | MED-HIGH | 1140 | 1110 | 1080 | 1050 | 1020 | 960 | 900 |
| MED-LOW | 900 | 885 | 870 | 855 | 840 | 790 | 740 | |||
| LOW | 650 | 645 | 640 | 635 | 630 | 610 | 580 | |||
| 36/37UC0W | 1/2 | 8.1 | HIGH | 1160 | 1135 | 1110 | 1080 | 1050 | 990 | 930 |
| MED-HIGH | 1120 | 1095 | 1070 | 1045 | 1020 | 970 | 900 | |||
| MED-LOW | 890 | 875 | 860 | 845 | 830 | 790 | 740 | |||
| 38UC0W | 1/2 | 8.1 | HIGH | 1400 | 1375 | 1350 | 1325 | 1300 | 1250 | 1200 |
| MED | 1260 | 1245 | 1230 | 1210 | 1190 | 1150 | 1100 | |||
| LOW | 1090 | 1080 | 1070 | 1055 | 1040 | 1010 | 970 |
Diagram showing the UC0W unit with labeled dimensions (A-E), water inlet/outlet, high/low voltage connections, liquid/suction lines, and optional drain outlets. Also shows opening dimensions with cover removed.
UCOQ Series: Hydronic Heat w/Circulator Pump & PSC Motor
The UCOQ series is designed for hydronic heating with a circulator pump and PSC motor, compatible with gas-fired water heaters or boilers.
Features:
- Compatible with gas-fired water heaters or boilers up to 45,300 BTUH hydronic heat.
- All coil connections are sweat.
- Optional features include Wall Panels, TXV Kits, Condensate Overflow Switch, Closet Hanger Bracket Kit, and Bottom Return Air Kit.
Physical Dimensions:
| UNIT MODEL | A | B | C | D | E | FILTER SIZE | LIQUID LINE | SUCTION LINE |
|---|---|---|---|---|---|---|---|---|
| 18-25UC0Q | 22-1/8 | 18 | 43 | 18 | 12-1/2 | 18 X 18 | 3/8" O.D. | 5/8" O.D. |
| 26/31UC0Q | 22-1/8 | 18 | 43 | 18 | 12-1/2 | 18 X 20 | 3/8" O.D. | 3/4" O.D. |
| 32-37UC0Q | 22-1/8 | 21 | 43 | 18 | 15-1/2 | 18 X 24 | 3/8" O.D. | 3/4" O.D. |
| 38UC0Q | 28-1/8 | 21 | 46 | 24-1/8 | 15-3/4 | 24 X 24 | 3/8" O.D. | 7/8" O.D. |
Performance Data (Hydronic Heat w/Circulator Pump & PSC Motor):
Performance Data:
| UNIT MODEL | NOMINAL COOLING BTUH | HEATING BTUH (1000) ENTERING TEMPERATURE Delta -T 20°F & GPM | AMPS (MOTOR) (120V) | AMPS Low Flow Bronze Bump | AMPS Med. Flow Cast Iron Pump | MIN. CIRCUIT AMPACITY | MAX. FUSE OR HACR BREAKER | ||
|---|---|---|---|---|---|---|---|---|---|
| 120°F GPM | 140°F GPM | 180°F GPM | |||||||
| 18-20UC0Q | 18,000 | 18.5 1.9 | 25.9 2.6 | 5.4 | 0.75 | 0.54 | 8 | 15 | |
| 24-26UC0Q | 24,000/ 18,000 | 22.1 2.2 | 31.0 3.1 | 5.4 | 0.75 | 0.54 | 8 | 15 | |
| 30-31UC0Q | 30,000/ 24,000 | 25.0 2.5 | 35.1 3.5 | 8.1 | 0.75 | 0.54 | 11 | 15 | |
| 32UC0Q | 30,000 / 24,000 | 27.0 2.7 | 37.7 3.8 | 8.1 | 0.75 | 0.54 | 11 | 15 | |
| 36/37UC0Q | 36,000/30,000 | 29.6 3.0 | 41.3 4.1 | 8.1 | 0.75 | 0.54 | 11 | 15 | |
| 38UC0Q | 36,000 / 30,000 | 32.3 3.2 | 45.3 4.5 | 8.1 | 0.75 | 0.54 | 11 | 15 |
Diagram showing the UC0Q unit with labeled dimensions (A-E), water inlet/outlet, high/low voltage connections, liquid/suction lines, and optional drain outlets. Also shows opening dimensions with cover removed.
UCX Series: Electric Heat w/ECM Motor
The UCX series features electric heat with an ECM motor, offering higher efficiency.
Features:
- ECM motor for improved efficiency.
- Standard features similar to UCO series regarding cabinet and drain connections.
Physical Dimensions:
| UNIT MODEL | A | B | C | D | E | F | FILTER SIZE | LIQUID LINE | SUCTION LINE |
|---|---|---|---|---|---|---|---|---|---|
| 19-25UCX | 22-1/8 | 15-1/8 | 40 | 14 | 10-1/2 | 3-5/8 | 18 X 18 | 3/8 O.D. | 5/8 O.D. |
| 26, 31UCX | 22-1/8 | 15-1/8 | 40 | 14 | 10-1/2 | 3-5/8 | 18 X 20 | 3/8 O.D. | 3/4 O.D. |
| 32, 37UCX | 22-1/8 | 18-1/8 | 43 | 14 | 13 | 3-5/8 | 18 X 24 | 3/8 O.D. | 3/4 O.D. |
| 38UCX | 28-1/8 | 21 | 46 | 16-1/2 | 13 | 7-1/2 | 24 x 24 | 3/8 O.D. | 7/8 O.D. |
Performance Data (Electric Heat w/ECM Motor):
Performance Data Tables
Electric Heat Capacity:
| UNIT MODEL | NOM. CFM | NOM. COOL BTUH | ELECTRIC HEAT CAPACITY (kW) | ELECTRIC HEAT CAPACITY (BTUH) | TOTAL AMPS | MIN. AMPACITY | MAX. OVERCURRENT PROTECTION | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 240V | 208V | 240V | 208V | 240V | 208V | 240V | 208V | 240V | 208V | |||
| 19UCX | 600 | 18000 | 3 | 2.3 | 10236 | 6824 | 15.3 | 13.6 | 20 | 18 | 20 | 20 |
| 20UCX | 4 | 3.0 | 13648 | 10236 | 19.5 | 17.2 | 25 | 22 | 25 | 25 | ||
| 25UCX | 800 | 24000/18000 | 5 | 3.8 | 17061 | 13648 | 23.6 | 20.8 | 30 | 27 | 30 | 30 |
| 26UCX | 6 | 4.5 | 20473 | 15355 | 27.8 | 24.4 | 35 | 31 | 35 | 35 | ||
| 31UCX | 1000 | 30000/24000 | 8 | 6.0 | 27297 | 20473 | 36.1 | 31.6 | 46 | 40 | 50 | 40 |
| 10 | 7.5 | 34121 | 25591 | 44.5 | 38.9 | 56 | 49 | 60 | 50 | |||
| 32UCX | 1200 | 36000/30000 | 3 | 2.3 | 10236 | 6824 | 16.6 | 14.9 | 21 | 19 | 25 | 20 |
| 37UCX | 4 | 3.0 | 13648 | 10236 | 20.8 | 18.5 | 26 | 24 | 30 | 25 | ||
| 38UCX | 5 | 3.8 | 17061 | 13648 | 24.9 | 22.1 | 32 | 28 | 35 | 30 | ||
| 6 | 4.5 | 20473 | 15355 | 29.1 | 25.7 | 37 | 33 | 40 | 35 | |||
| 8 | 6.0 | 27297 | 20473 | 37.4 | 32.9 | 47 | 42 | 50 | 45 | |||
| 10 | 7.5 | 34121 | 25591 | 45.8 | 40.2 | 58 | 50 | 60 | 50 | |||
Blower Data (CFM vs. External Static Pressure):
| MODEL | MOTOR HP | FAN SPEED TAP | BHP | NOM. AMPS | 0.10 | 0.20 | 0.30 | 0.40 | 0.50 |
|---|---|---|---|---|---|---|---|---|---|
| 19UCX | 1/3 | 5 | 0.23 | 1.9 | 850 | 800 | 770 | 730 | 690 |
| 20UCX | 4 | 0.16 | 1.2 | 680 | 650 | 610 | 570 | 540 | |
| 3 | 0.13 | 1.0 | 610 | 570 | 530 | 490 | 460 | ||
| 25UCX | 1/3 | 5 | 0.33 | 2.4 | 1030 | 970 | 930 | 890 | 850 |
| 26UCX | 4 | 0.25 | 2.1 | 890 | 830 | 810 | 780 | 760 | |
| 3 | 0.19 | 1.5 | 770 | 710 | 680 | 640 | 610 | ||
| 2 | 0.15 | 1.2 | 670 | 600 | 570 | 530 | 500 | ||
| 31UCX | 1/2 | 4 | 0.50 | 2.8 | 1190 | 1090 | 1040 | 980 | 930 |
| 3 | 0.37 | 2.6 | 1120 | 1060 | 1010 | 960 | 910 | ||
| 2 | 0.27 | 2.0 | 940 | 880 | 860 | 830 | 790 | ||
| 1 | 0.21 | 1.5 | 820 | 760 | 730 | 700 | 670 | ||
| 32UCX | 3/4 | 4 | 0.41 | 2.9 | 1250 | 1190 | 1150 | 1120 | 1070 |
| 3 | 0.35 | 2.5 | 1090 | 1030 | 990 | 960 | 920 | ||
| 2 | 0.25 | 1.5 | 980 | 910 | 870 | 840 | 810 | ||
| 1 | 0.19 | 1.0 | 870 | 790 | 740 | 700 | 670 | ||
| 37UCX | 3/4 | 5 | 0.75 | 3.9 | 1450 | 1330 | 1260 | 1190 | 1120 |
| 4 | 0.41 | 3.1 | 1250 | 1190 | 1150 | 1120 | 1070 | ||
| 3 | 0.33 | 2.3 | 1090 | 1030 | 990 | 960 | 920 | ||
| 2 | 0.27 | 1.9 | 980 | 910 | 870 | 840 | 810 | ||
| 38UCX | 3/4 | 5 | 0.53 | 3.5 | 1400 | 1350 | 1320 | 1290 | 1230 |
| 4 | 0.47 | 2.8 | 1310 | 1250 | 1230 | 1200 | 1180 | ||
| 3 | 0.38 | 2.1 | 1160 | 1100 | 1070 | 1040 | 1000 | ||
| 2 | 0.34 | 1.8 | 1090 | 1020 | 990 | 960 | 930 |
Diagram showing a UCX unit with labels for dimensions A through F, and openings for service access.
UCXW Series: Hydronic Heat w/ECM Motor & DX Coil for Cooling
The UCXW series combines hydronic heating with an ECM motor and a DX coil for cooling, offering enhanced efficiency.
Features:
- ECM motor for improved efficiency.
- Compatible with tankless water heaters and split-system heat pumps.
- Unique feature for recessed wall applications: hot water coil can be removed without drywall modification.
Physical Dimensions:
| UNIT MODEL | A | B | C | D | E | FILTER SIZE | LIQUID LINE | SUCTION LINE |
|---|---|---|---|---|---|---|---|---|
| 12-25UCX-HW | 22-1/8 | 18 | 43 | 18 | 12-1/2 | 18 X 18 | 3/8" O.D. | 5/8" O.D. |
| 26/31UCX-HW | 22-1/8 | 18 | 43 | 18 | 12-1/2 | 18 X 20 | 3/8" O.D. | 3/4" O.D. |
| 32/37UCX-HW | 22-1/8 | 21 | 43 | 18 | 15-1/2 | 18 X 24 | 3/8" O.D. | 3/4" O.D. |
| 38UCX-HW | 28-1/8 | 21 | 46 | 24-1/8 | 15-3/4 | 24 X 24 | 3/8" O.D. | 7/8" O.D. |
Performance Data (Hydronic Heat w/ECM Motor & DX Coil):
Performance Data:
| UNIT MODEL | NOM. COOLING BTUH | P.D. FT. WTR. COIL ONLY | HEATING BTUH (1000) AT ENTERING WATER TEMPERATURE Delta-T 20°F & GPM | MOTOR SPEED TAP CONNECTION | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 120°F GPM | 140°F GPM | 180°F GPM | HIGH SPD (VIO LEAD) | LOW SPD (GRY LEAD) | |||||||
| 12UCXW | 12,000 | 3.3 | 11.4 | 1.1 | 16.0 | 1.6 | 25.1 | 2.5 | GRY | VIO | |
| 2.1 | 11.1 | 1.1 | 15.6 | 1.6 | 24.5 | 2.5 | 1 | ||||
| 1.2 | 10.8 | 1.1 | 15.1 | 1.5 | 23.7 | 2.4 | |||||
| 19/20UCXW | 18,000 | 3.3 | 19.1 | 1.9 | 26.8 | 2.7 | 42.1 | 4.2 | 2 | 1 | |
| 2.1 | 18.5 | 1.9 | 25.9 | 2.6 | 40.7 | 4.1 | |||||
| 1.2 | 17.6 | 1.8 | 24.9 | 2.5 | 38.7 | 3.9 | |||||
| 25/26UCXW | 24,000 / 18,000 | 3.3 | 22.9 | 2.3 | 32.1 | 3.2 | 50.4 | 5.0 | 3 | 2 | |
| 2.1 | 22.1 | 2.2 | 31.0 | 3.1 | 48.7 | 4.9 | 1 | ||||
| 1.2 | 20.8 | 2.1 | 29.2 | 2.9 | 45.9 | 4.6 | |||||
| 31/32UCXW | 30,000 / 24,000 | 3.3 | 26.1 | 2.6 | 36.5 | 3.7 | 57.3 | 5.7 | 3 | 2 | |
| 2.1 | 25.0 | 2.5 | 35.1 | 3.5 | 55.1 | 5.5 | 1 | ||||
| 1.2 | 23.5 | 2.4 | 32.9 | 3.3 | 51.7 | 5.2 | |||||
| 37/38UCXW | 36,000 / 30,000 | 3.6 | 28.1 | 2.8 | 39.3 | 3.9 | 61.7 | 6.2 | 3 | 2 | |
| 2.4 | 26.9 | 2.7 | 37.7 | 3.8 | 59.2 | 5.9 | 1 | ||||
| 1.3 | 25.2 | 2.5 | 35.3 | 3.5 | 55.4 | 5.5 | |||||
| 3.6 | 30.9 | 3.1 | 43.2 | 4.3 | 67.9 | 6.8 | 3 | 2 | |||
| 2.4 | 29.6 | 3.0 | 41.3 | 4.1 | 64.9 | 6.5 | 1 | ||||
| 1.3 | 27.5 | 2.8 | 38.5 | 3.9 | 60.5 | 6.1 | |||||
Blower Data (CFM vs. External Static Pressure):
| UNIT MODEL | MOTOR H.P. (120V) | MOTOR AMPS (120V) | BHP | RUNNING AMPS | SPEED TAP | 0.10 | 0.15 | 0.20 | 0.25 | 0.30 | 0.40 | 0.50 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 12UCXW | 1/4 | 3.5 | .11 | 1.6 | WHT | 575 | 555 | 540 | 525 | 505 | 465 | 425 |
| .09 | 1.3 | GRY | 525 | 505 | 490 | 470 | 450 | 405 | 360 | |||
| 19/20UCXW | 1/3 | 4.8 | .24 | 3.0 | VIO | 300 | 275 | 250 | 225 | 200 | 155 | -- |
| .21 | 2.6 | 3 | 690 | 675 | 660 | 645 | 630 | 600 | 570 | |||
| .16 | 1.7 | 2 | 650 | 630 | 610 | 590 | 570 | 540 | 510 | |||
| .36 | 4.1 | 1 | 530 | 510 | 490 | 470 | 450 | 420 | 390 | |||
| 25/26UCXW | 1/2 | 6.8 | .23 | 2.4 | 3 | 880 | 865 | 850 | 835 | 820 | 790 | 760 |
| .17 | 1.7 | 2 | 670 | 655 | 640 | 625 | 610 | 580 | 550 | |||
| .50 | 5.1 | 1 | 570 | 550 | 530 | 515 | 500 | 470 | 440 | |||
| 31UCXW | 1/2 | 6.8 | .34 | 3.6 | 3 | 930 | 910 | 890 | 870 | 850 | 810 | 760 |
| .22 | 2.1 | 2 | 800 | 785 | 770 | 750 | 730 | 700 | 690 | |||
| .37 | 4.2 | 1 | 610 | 595 | 580 | 565 | 550 | 510 | 480 | |||
| 32UCXW | 3/4 | 8.4 | .24 | 2.6 | 3 | 1010 | 1000 | 990 | 975 | 960 | 930 | 900 |
| .20 | 2.0 | 2 | 790 | 775 | 760 | 745 | 730 | 700 | 670 | |||
| .75 | 6.7 | 1 | 700 | 685 | 670 | 650 | 630 | 600 | 560 | |||
| 37UCXW | 3/4 | 8.4 | .49 | 5.5 | 3 | 1250 | 1230 | 1210 | 1190 | 1170 | 1120 | 1070 |
| .37 | 4.0 | 2 | 1110 | 1095 | 1080 | 1065 | 1050 | 1020 | 990 | |||
| .47 | 5.6 | 1 | 940 | 925 | 910 | 895 | 880 | 850 | 820 | |||
| 38UCXW | 3/4 | 8.4 | .38 | 5.2 | 3 | 1240 | 1230 | 1220 | 1205 | 1190 | 1160 | 1130 |
| .25 | 2.3 | 2 | 1100 | 1090 | 1080 | 1065 | 1050 | 1020 | 990 | |||
| .25 | 2.3 | 1 | 860 | 845 | 830 | 815 | 800 | 760 | 730 |
Diagram showing the UCXW unit with labeled dimensions (A-E), water inlet/outlet, high/low voltage connections, liquid/suction lines, and optional drain outlets. Also shows opening dimensions with cover removed.
UCXRX Series: Hydronic Heat w/Hi Flow Pump & ECM Motor
The UCXRX series is designed for high efficiency with a hi-flow pump and ECM motor, specifically for use with tankless water heaters, providing both domestic hot water and space heating.
Features:
- High efficiency ECM motor.
- Special circulating pump for tankless heaters.
- Includes HW check valve, air purge valve, hot water coil, cooling coil, and multi-function circuit board.
- Compatible with any source of hot water up to 180°F and NSF/ANSI certified for domestic water use.
- Can be installed in closets or recessed in walls.
Performance Data (Hydronic Heat w/Hi Flow Pump & ECM Motor):
Performance Data:
| UNIT MODEL | NOM. CFM | HTG. GPM (NOM.) | HEATING BTUH (1000) AT ENTERING WATER TEMPERATURE (1) Delta - T 20°F & GPM | TOTAL AMPS (MOTOR) (120V) | TOTAL AMPS (PUMP) (120V) | MIN. CIRCUIT AMPACITY | MAX. CIRCUIT PROTEC- TION | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 120°F | 130° | 140°F | 150°F | 160°F | ||||||||
| 12UCXRX | 275 | 4 | 11.3 1.1 | 13.6 1.4 | 15.9 1.4 | 18.1 1.8 | 20.4 2.0 | 3.5 | .84 | 6 | 15 | |
| 19/20UCXRX | 450 | 4 | 15.6 1.6 | 18.8 1.9 | 21.9 1.9 | 25.0 2.5 | 28.2 2.8 | 4.8 | .84 | 7 | 15 | |
| 25/26UCXRX | 610 | 4 | 19.1 1.9 | 22.9 2.3 | 26.7 2.3 | 30.5 3.1 | 34.3 3.4 | 6.8 | .84 | 10 | 15 | |
| 31UCXRX | 730 | 4 | 21.3 2.1 | 25.6 2.6 | 29.9 2.6 | 34.2 3.4 | 38.5 3.9 | 6.8 | .84 | 10 | 15 | |
| 32UCXRX | 730 | 4 | 22.7 2.3 | 27.3 2.7 | 31.8 2.7 | 36.3 3.6 | 40.9 4.1 | 8.4 | .84 | 12 | 15 | |
| 37UCXRX | 1050 | 4 | 28.3 2.8 | 34.0 3.4 | 39.7 3.4 | 45.4 4.5 | 51.1 5.1 | 8.4 | .84 | 12 | 15 | |
| 38UCXRX | 1050 | 4 | 30.6 3.1 | 36.7 3.7 | 42.8 3.7 | 48.9 4.9 | 55.0 5.5 | 8.4 | .84 | 12 | 15 | |
Blower Data (CFM vs. External Static Pressure):
| UNIT MODEL | MOTOR H.P. (120V) | MOTOR AMPS (120V) | BHP | RUNNING AMPS | SPEED TAP | 0.10 | 0.15 | 0.20 | 0.25 | 0.30 | 0.40 | 0.50 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 12UCXRX | 1/4 | 3.5 | .11 | 1.6 | WHT | 575 | 555 | 540 | 525 | 505 | 465 | 425 |
| .09 | 1.3 | GRY | 525 | 505 | 490 | 470 | 450 | 405 | 360 | |||
| 19/20UCXRX | 1/3 | 4.8 | .24 | 3.0 | VIO | 300 | 275 | 250 | 225 | 200 | 155 | -- |
| .21 | 2.6 | 3 | 690 | 675 | 660 | 645 | 630 | 600 | 570 | |||
| .16 | 1.7 | 2 | 650 | 630 | 610 | 590 | 570 | 540 | 510 | |||
| .36 | 4.1 | 1 | 530 | 510 | 490 | 470 | 450 | 420 | 390 | |||
| 25/26UCXRX | 1/2 | 6.8 | .23 | 2.4 | 3 | 880 | 865 | 850 | 835 | 820 | 790 | 760 |
| .17 | 1.7 | 2 | 670 | 655 | 640 | 625 | 610 | 580 | 550 | |||
| .50 | 5.1 | 1 | 570 | 550 | 530 | 515 | 500 | 470 | 440 | |||
| 31UCXRX | 1/2 | 6.8 | .34 | 3.6 | 3 | 930 | 910 | 890 | 870 | 850 | 810 | 760 |
| .22 | 2.1 | 2 | 800 | 785 | 770 | 750 | 730 | 700 | 690 | |||
| .37 | 4.2 | 1 | 610 | 595 | 580 | 565 | 550 | 510 | 480 | |||
| 32UCXRX | 3/4 | 8.4 | .24 | 2.6 | 3 | 1010 | 1000 | 990 | 975 | 960 | 930 | 900 |
| .20 | 2.0 | 2 | 790 | 775 | 760 | 745 | 730 | 700 | 670 | |||
| .75 | 6.7 | 1 | 700 | 685 | 670 | 650 | 630 | 600 | 560 | |||
| 37UCXRX | 3/4 | 8.4 | .49 | 5.5 | 3 | 1250 | 1230 | 1210 | 1190 | 1170 | 1120 | 1070 |
| .37 | 4.0 | 2 | 1110 | 1095 | 1080 | 1065 | 1050 | 1020 | 990 | |||
| .47 | 5.6 | 1 | 940 | 925 | 910 | 895 | 880 | 850 | 820 | |||
| 38UCXRX | 3/4 | 8.4 | .38 | 5.2 | 3 | 1240 | 1230 | 1220 | 1205 | 1190 | 1160 | 1130 |
| .25 | 2.3 | 2 | 1100 | 1090 | 1080 | 1065 | 1050 | 1020 | 990 | |||
| .25 | 2.3 | 1 | 860 | 845 | 830 | 815 | 800 | 760 | 730 |
Diagram showing the UCXRX unit with labeled dimensions (A-E), water inlet/outlet, high/low voltage connections, liquid/suction lines, and optional drain outlets. Also shows opening dimensions with cover removed.
Accessories
Various optional accessories are available for the UC Series fan coils, including:
- Wall Panels (Louvered or Solid)
- Hanger Bracket Sets
- Bottom Return Air Kits
- Heater Kits (3kW, 5kW, 6kW, 8kW, 10kW)
- Condensate Overflow Kits
- Expansion Valve Kits (for cooling only or heat pump applications)
- Condensate Overflow Switch
- Freeze Protector
Detailed part numbers and dimensions for these accessories are provided in the tables within each series section.