FCC RF Test Report

WBU ation Depr.

Test report

Lenovo (Shanghai) Electronics Technology Co., Ltd TB8506F Portable Tablet Computer O57TB8506F O57TB8506F tb8506f

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=5216445
FCC RF Test Report

Report No. : FR120606-06D

FCC RF Test Report

APPLICANT

: Lenovo(Shanghai) Electronics Technology Co., Ltd.

EQUIPMENT

: Portable Tablet Computer

BRAND NAME : Lenovo

MODEL NAME : Lenovo TB-8506F

FCC ID

: O57TB8506F

STANDARD

: FCC Part 15 Subpart E §15.407

CLASSIFICATION : (NII) Unlicensed National Information Infrastructure

This is a data re-used report which is only valid together with the original test report. We, Sporton International (Kunshan) Inc., would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards.
The test results in this report apply exclusively to the tested model / sample. Without written approval of Sporton International (Kunshan) Inc., the test report shall not be reproduced except in full.

Reviewed by: Jason Jia / Supervisor

Approved by: Alex Wang / Manager
Sporton International (Kunshan) Inc.
No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: 1 of 8

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01

Report Template No.: BU5-FR15EWL AC MA Version 2.0

FCC RF Test Report

Report No. : FR120606-06D

TABLE OF CONTENTS
REVISION HISTORY..........................................................................................................................................3 1 GENERAL DESCRIPTION..........................................................................................................................4
1.1 Applicant ............................................................................................................................................ 4 1.2 Manufacturer......................................................................................................................................4 1.3 Product Feature of Equipment Under Test........................................................................................4 1.4 Product Specification of Equipment Under Test................................................................................4 1.5 Modification of EUT ........................................................................................................................... 5 1.6 Testing Location ................................................................................................................................ 5 1.7 Test Software.....................................................................................................................................5 1.8 Applicable Standards.........................................................................................................................5 1.9 Re-use of Measured Data ................................................................................................................. 6 2 LIST OF MEASURING EQUIPMENT..........................................................................................................7 3 UNCERTAINTY OF EVALUATION.............................................................................................................8 APPENDIX A. SETUP PHOTOGRAPHS APPENDIX B. REFERENCE REPORT

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: 2 of 8

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01

Report Template No.: BU5-FR15EWL AC MA Version 2.0

FCC RF Test Report

Report No. : FR120606-06D

REVISION HISTORY

REPORT NO. VERSION

DESCRIPTION

FR120606-06D Rev. 01 Initial issue of report

ISSUED DATE Apr. 21, 2021

Declaration of Conformity:
The test results with all measurement uncertainty excluded are presented in accordance with the regulation limits or requirements declared by manufacturers.
Comments and Explanations:
The declared of product specification for EUT presented in the report are provided by the manufacturer, and the manufacturer takes all the responsibilities for the accuracy of product specification.

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: 3 of 8

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01

Report Template No.: BU5-FR15EWL AC MA Version 2.0

FCC RF Test Report

Report No. : FR120606-06D

1 General Description
1.1 Applicant
Lenovo(Shanghai) Electronics Technology Co., Ltd. Section 304-305, Building No. 4, # 222, Meiyue Road, China (Shanghai) Pilot Free Trade Zone
1.2 Manufacturer
Lenovo PC HK Limited 23/F, Lincoln House, Taikoo Place 979 King's Road, Quarry Bay, Hong Kong, P.R.China

1.3 Product Feature of Equipment Under Test

Product Feature

Equipment Brand Name Model Name FCC ID
EUT supports Radios application
HW Version SW Version EUT Stage

Portable Tablet Computer Lenovo Lenovo TB-8506F O57TB8506F WLAN 2.4GHz 802.11b/g/n HT20/HT40 WLAN 5GHz 802.11a/n HT20/HT40 WLAN 5GHz 802.11ac VHT20/VHT40/VHT80 Bluetooth BR/EDR/LE FM Receiver and GNSS
Lenovo TB-8506F Lenovo TB-8506F_RF01_210305 Identical Prototype

Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications

or user's manual for more detailed description.

1.4 Product Specification of Equipment Under Test

Tx/Rx Frequency Range Antenna Type / Gain Type of Modulation

Standards-related Product Specification
5180 MHz ~ 5240 MHz 5260 MHz ~ 5320 MHz 5500 MHz ~ 5720 MHz <5180 MHz ~ 5240 MHz> IFA Antenna with gain -6.47 dBi <5260 MHz ~ 5320 MHz> IFA Antenna with gain -6.43 dBi <5500 MHz ~ 5720 MHz> IFA Antenna with gain -6.39 dBi 802.11a/n : OFDM (BPSK / QPSK / 16QAM / 64QAM) 802.11ac : OFDM (BPSK / QPSK / 16QAM / 64QAM / 256QAM)

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: 4 of 8

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01

Report Template No.: BU5-FR15EWL AC MA Version 2.0

FCC RF Test Report
1.5 Modification of EUT
No modifications are made to the EUT during all test items.

Report No. : FR120606-06D

1.6 Testing Location

Sporton International (Kunshan) Inc. is accredited to ISO/IEC 17025:2017 by American Association for Laboratory Accreditation with Certificate Number 5145.02.

Test Firm

Sporton International (Kunshan) Inc.

Test Site Location Test Site No.

No. 1098, Pengxi North Road, Kunshan Economic Development Zone

Jiangsu Province 215300 People's Republic of China

TEL : +86-512-57900158 FAX : +86-512-57900958

Sporton Site No. FCC Designation No.

FCC Test Firm Registration No.

03CH06-KS

CN1257

314309

1.7 Test Software
Item Site 1. 03CH06-KS

Manufacturer AUDIX

Name E3

Version 6.2009-8-24al

1.8 Applicable Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:  47 CFR Part 15 Subpart E  FCC KDB 789033 D02 General UNII Test Procedures New Rules v02r01..  ANSI C63.10-2013

Remark: 1. All test items were verified and recorded according to the standards and without any deviation
during the test. 2. This EUT has also been tested and complied with the requirements of FCC Part 15, Subpart B,
recorded in a separate test report.

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: 5 of 8

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01

Report Template No.: BU5-FR15EWL AC MA Version 2.0

FCC RF Test Report

Report No. : FR120606-06D

1.9 Re-use of Measured Data
1.9.1 Introduction Section
This application re-uses data collected on a similar device. The subject device of this application (Model: Lenovo TB-8506F, FCC ID: O57TB8506F) is electrically identical to the reference device (Model: Lenovo TB-8506X, FCC ID: O57TB8506X) for the portions of the circuitry corresponding to the data being re-used, as treated by KDB Publication 484596 D01.

1.9.2 Difference Section
For details concerning the similarity with respect to component placement, mechanical/electrical design etc., please refer to the Product Equality Declaration.
The re-used RF data includes the following bands provided in Appendix B (Sporton RF Report No. FR120606-01D for the reference device Model: Lenovo TB-8506X, FCC ID: O57TB8506X).

1.9.3 Reference detail Section:

Equipment Class NII (B1~3) NII (B4) DFS

Reference FCC ID O57TB8506X O57TB8506X O57TB8506X

Folder Test Part15E(FR120606-01D) Part15E(FR120606-01E) Part15E(FZ120606-01)

Report Title/Section All sections applicable All sections applicable All sections applicable

1.9.4 Spot Check Verification Data Section
In order to confirm hardware similarity of the subject device with the reference device, spot check measurements were performed on the subject device for the following test items, the test result were consistent with FCC ID: O57TB8506X.
Assertions concerning the similarity of these devices are based on representations by the applicant. The applicant accepts full responsibility for the validity of the similarity claim, and for the determination that verification test data are sufficient to support it.

Test Item
Radiated Spurious Emission (Band Edge. Haromic) (dBuV/m)

Mode 802.11n HT20 CH64 802.11n HT40 CH151

O57TB8506X Worst Result
50.87
58.65

O57TB8506F Worst Result
50.23
57.02

Difference (dB) 0.64 1.63

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: 6 of 8

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01

Report Template No.: BU5-FR15EWL AC MA Version 2.0

FCC RF Test Report

Report No. : FR120606-06D

2 List of Measuring Equipment

Instrument

Calibration Manufacturer Model No. Serial No. Characteristics
Date

Test Date

Due Date

Remark

EMI Test Receiver Keysight

N9038A

MY564000 3Hz~8.5GHz;M

04

ax 30dBm

Oct. 17, 2020

Mar. 21, 2021

Oct. 16, 2021

Radiation (03CH06-KS)

EXA Spectrum Analyzer

Keysight

N9010A

MY551502 08

10Hz-44GHz

Apr. 14, 2020

Mar. 21, 2021

Apr. 13, 2021

Radiation (03CH06-KS)

Loop Antenna

R&S

HFH2-Z2

100321

9kHz~30MHz

Nov. 01, 2020

Mar. 21, 2021

Oct. 31, 2021

Radiation (03CH06-KS)

Bilog Antenna

TeseQ

CBL6111D

49921

30MHz-1GHz

May 29, 2020

Mar. 21, 2021

May 28, 2021

Radiation (03CH06-KS)

Double Ridge Horn Antenna

ETS-Lindgren

3117

00218652

1GHz~18GHz

Apr. 27, 2020 Mar. 21, 2021 Apr. 26, 2021

Radiation (03CH06-KS)

SHF-EHF Horn Com-power

AH-840

101115

18GHz~40GHz

Nov. 10, 2019

Mar. 21, 2021

Nov. 09, 2020

Radiation (03CH06-KS)

Amplifier

SONOMA

310N

187289

9KHz ~1GHZ

Apr. 14, 2020

Mar. 21, 2021

Apr. 13, 2021

Radiation (03CH06-KS)

Amplifier

MITEQ

EM18G40GG A

060728

18~40GHz

Jan. 06, 2021

Mar. 21, 2021

Jan. 05, 2022

Radiation (03CH06-KS)

high gain Amplifier

MITEQ

AMF-7D-0010 1800-30-10P

2025788

1Ghz-18Ghz

Jan. 06, 2021

Mar. 21, 2021

Jan. 05, 2022

Radiation (03CH06-KS)

Amplifier

Keysight

83017A

MY532702 500MHz~26.5G

03

Hz

Apr. 15, 2020

Mar. 21, 2021

Apr. 14, 2021

Radiation (03CH06-KS)

AC Power Source Chroma

61601

F1040900 04

N/A

NCR

Mar. 21, 2021

NCR

Radiation (03CH06-KS)

Turn Table

ChamPro EM 1000-T 060762-T 0~360 degree

NCR

Mar. 21, 2021

NCR

Radiation (03CH06-KS)

Antenna Mast

ChamPro EM 1000-A 060762-A 1 m~4 m

NCR

Mar. 21, 2021

NCR

Radiation (03CH06-KS)

NCR: No Calibration Required

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: 7 of 8

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01

Report Template No.: BU5-FR15EWL AC MA Version 2.0

FCC RF Test Report

Report No. : FR120606-06D

3 Uncertainty of Evaluation
The measurement uncertainties shown below were calculated in accordance with the requirements of ANSI 63.10-2013. All the measurement uncertainty value were shown with a coverage K=2 to indicate 95% level of confidence. The measurement data show herein meets or exceeds the CISPR measurement uncertainty values specified in CISPR 16-4-2 and can be compared directly to specified limit to determine compliance.

Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz)

Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

5.0dB

Uncertainty of Radiated Emission Measurement (1000 MHz ~ 18000 MHz)

Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

5.0dB

Uncertainty of Radiated Emission Measurement (18000 MHz ~ 40000 MHz)

Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

5.0dB

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: 8 of 8

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01

Report Template No.: BU5-FR15EWL AC MA Version 2.0

FCC RF Test Report

Report No. : FR120606-06D

Appendix B. Reference Report
Please refer to Sporton report number FR120606-01D & FZ120606-01 which is issued separately.

Sporton International (Kunshan) Inc. TEL : +86-512-57900158 FAX : +86-512-57900958 FCC ID: O57TB8506F

Page Number

: B1 of B1

Report Issued Date : Apr. 21, 2021

Report Version

: Rev. 01


Microsoft Word 2010 Microsoft Word 2010