apv-16-spec
16W Single Output Switching Power Supply

APV-16 series

   
SPECIFICATION

 


User's Manual




























 LPS IP42

IS 15885(Part 2/Sec13)

THOMAS SAMUEL

THOMAS SAMUEL

R-41027766



MODEL

APV-16-5

APV-16-12

APV-16-15

APV-16-24

OUTPUT

DC VOLTAGE

5V

12V

15V

RATED CURRENT

2.6A

1.25A

1A

CURRENT RANGE

0 ~ 2.6A

0 ~ 1.25A

0 ~ 1A

RATED POWER

13W

15W

15W

RIPPLE & NOISE (max.) Note.2 100mVp-p

120mVp-p

120mVp-p

VOLTAGE TOLERANCE Note.3 ±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME Note.6 1500ms, 30ms / 230VAC

1500ms,30ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC 12ms/115VAC at full load

24V 0.67A 0 ~ 0.67A 16.08W 150mVp-p

VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

INPUT

EFFICIENCY (Typ.)

76%

80%

81%

83%

AC CURRENT

0.3A/230VAC 0.5A/115VAC

INRUSH CURRENT(Typ.)

COLD START 50A(twidth=250s measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

13 units (circuit breaker of type B) / 22 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

OVER LOAD PROTECTION
OVER VOLTAGE
WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION

Above 105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

5.75 ~ 6.75V

13.8 ~ 16V

17.5 ~ 21V

Protection type : Shut off o/p voltage, clamping by zener diode

-30 ~ +70(Refer to "Derating Curve")

20 ~ 90% RH non-condensing

-40 ~ +80, 10 ~ 95% RH

±0.03%/ (0 ~ 50)

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

27.6 ~ 32.4V

SAFETY STANDARDS Note.8

UL8750,CSA C22.2 No.250.0-08, BIS IS15885(except for 15V),EAC TP TC 004,IP42 , BS EN/EN 62368-1 approved

SAFETY & WITHSTAND VOLTAGE

EMC

ISOLATION RESISTANCE

EMC EMISSION

I/P-O/P:3.75KVAC I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS EN/EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to BS EN/EN55035,BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), EAC TP TC 020

MTBF

7265.5K hrs min. Telcordia SR-332 (Bellcore) ; 1128.9K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

77*40*29mm (L*W*H)

PACKING

0.1Kg; 120pcs/14Kg/1.06CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltage. Please check the static characteristics for more details. Please connect L line to the positive pole and

N line to the negative pole under DC input.

5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the

complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

7. This product is not intended for LED lighting luminaire applications in the EU and China.(In the EU and China the LPF/NPF/XLG/XLC/XLN series

are recommended.)

8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

9. Products sourced from the Americas regions may not have the ENEC/BIS logo. Please contact your MEAN WELL sales for more information.

10. For any application note and IP water proof function installation caution, please refer our user manual before using.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf

Downloaded from Arrow.coPmro. duct Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:APV-16-SPEC 2024-10-16

16W Single Output Switching Power Supply
Mechanical Specification
90 82.5 77

AC/N(Blue) AC/L(Brown)

UL1569 18AWG 150±10

31 T case
 T case: Max. Case Temperature

APV-16 series
Unit:mm Tolerance:±1

150±10 UL1569 20AWG

+V(Red) -V(Black)

40 15.5
19 29

Block Diagram

I/P

EMI FILTER

RECTIFIERS

POWER SWITCH-
ING
PWM CONTROL

RECTIFIERS &
FILTER

DETECTION CIRCUIT

fosc : 67KHz
+V -V

Derating Curve

Static Characteristics

100
80
60 50 40
20
-30

0 10 20 30

40

50 60

70 (HORIZONTAL)

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40

90 100 200 210 220 230 240 250

264

INPUT VOLTAGE (VAC) 60Hz