User Guide for DAKTRONICS models including: DM-100, Handheld Digital Controller, Digital Controller, Handheld Controller, Controller, DM-100

Configuring the DM-100 Gen III for Sapphire Interface Quick ...

14 set 2022 — Press the Up and Down Arrow keys to select the appropriate test, and then press ENTER. • RS232 COM0 – Checks for a “loopback” jumper on pins 2 & 3 of the ...

Configuring the DM-100 Gen III for Sapphire Interface Quick Guide Page 1 of 8


File Info : application/pdf, 8 Pages, 339.37KB

PDF preview unavailable. Download the PDF instead.

dd2294807
Configuring the DM-100 Gen III for Sapphire Interface Quick Guide

Page 1 of 8

Handheld Controller Use and Setup
The first time you use your DM-100 handheld controller you may need to set the function to GAS PRICE as described below.

LCD Screen
CURRENT FUNCTION GAS PRICE

Action/Information Shown
For indoor installation only: Plug the wall pack transformer into a 120 VAC power outlet, and connect it to the DM-100. This display appears briefly.

CHANGE FUNCTION? PRESS SET FUNCT

If GAS PRICE is shown on the bottom line of the LCD during startup, do nothing. The controller automatically defaults to previous Gas Price settings.
If a function other than GAS PRICE is shown on the bottom line of the LCD during startup, press the SET FUNCTION key while the second LCD prompt is displayed.

SELECT FUNCTION Press the Up and Down Arrow keys until the gas price option is shown.

GAS PRICE

{} Press the ENTER key to accept.

Menu Navigation
1. Press the MENU key. 2. Press the Up and Down Arrow keys to select between
available menu options. 3. Press ENTER to select the desired menu option. 4. Press the MENU key to exit.

Menu Items

Diagnostics Menu Display Menu

Display Status

Price Options

Detect Displays

Configuration

Test Patterns

POS Settings

COM Diagnostics

POS Price Offset

About

Modem

Diagnostics Menu
Press the MENU key followed by ENTER to select the Diagnostics Menu.
Display Status
1. Press the MENU key followed by ENTER to select the Diagnostics Menu. 2. Press ENTER to open the Display Status menu item.

DIAGNOSTICS MENU ENT TO BEGIN
DISPLAY STATUS ENT TO SELECT

LCD Screen

DISPLAY STATUS GET STATUS

SELECT NETWORK

1

{}

SELECT DISPLAY SIGN 1 LINE 1 }

Action/Information Shown
Press ENTER to get display status.
Press the Up Arrow key to select another network, if applicable.
Press the Down Arrow key to move to another sign and line number.
Press ENTER to view Display Status menu items: · Driver Firmware Version · Dim Level · Dimming Mode (Automatic or Manual) · Light Sensor Status · Com1 Device Detection (Wired or Radio)

DD2294807 Rev 04 14 September 2022

201 Daktronics Drive Brookings, SD 57006-5128 www.daktronics.com/support
800.325.8766

Configuring the DM-100 Gen III for Sapphire Interface Quick Guide

Page 2 of 8

Detect Displays
1. Press the MENU key followed by ENTER to select the Diagnostics Menu.

DETECT DISPLAYS ENT TO BEGIN

2. Press the Down Arrow key to reach Display Detection, and then press ENTER.

LCD Screen

Action/Information Shown

SETUP IS SAVED CLEAR & DETECT?
ARE YOU SURE? ENT TO BEGIN
X NETWORKS FOUND

Press ENTER twice to begin the display detection process. The screen will cycle through all the displays it has detected.

NETWORK X OF Y

DETECTING DISPLAYS...
DETECTED SIGN X LX,Y,Z
SENDING CONFIGURATION
X NETWORKS FOUND CONFIG SAVED

LINE PRICE1 -RTX 1 } $1.11 9/10

After changing the network configuration the "RTX" message may appear in the upper-right corner of the LCD to indicate the DM-100 is attempting to (re) connect to all detected networks.

Test Patterns
1. Press the MENU key followed by ENTER to select the Diagnostics Menu. 2. Press the Down Arrow key to reach Test Patterns, and then press ENTER.

TEST PATTERNS ENT TO START

LCD Screen

Action/Information Shown

ENTER CYCLE BITS CLEAR TO EXIT

Press ENTER to start the CYCLE BITS test pattern. Each digit will turn on its segments one at a time. Press the Down Arrow key to move to the next test pattern.

ENTER DIAGNOSTIC CLEAR TO EXIT
ENTER CYCLE NUMS CLEAR TO EXIT

Press ENTER to start the DIAGNOSTIC test pattern. Press the Down Arrow key to move to the next test pattern.
Press ENTER to start the CYCLE NUMS test pattern. Each digit will display numbers 1-9 then blank and repeat.
Press CLEAR at any time to exit the test pattern menu.

DD2294807 Rev 04 14 September 2022

201 Daktronics Drive Brookings, SD 57006-5128 www.daktronics.com/support
800.325.8766

Configuring the DM-100 Gen III for Sapphire Interface Quick Guide

Page 3 of 8

COM Diagnostics
1. Press the MENU key followed by ENTER to select the Diagnostics Menu.

COM DIAGNOSTICS ENT TO SELECT

2. Press the Down Arrow key to reach COM Diagnostics, and then press ENTER.

LCD Screen

Action/Information Shown

DIAGNOSTICS POS PORT MONITOR
DIAGNOSTICS COM PORT TESTS
DIAGNOSTICS POS STATUS

There are three menu choices described below: · PoS Port Monitor · COM Port Tests · PoS Status
Press the Up and Down Arrow keys to select the appropriate menu choice.

DIAGNOSTICS POS PORT MONITOR

Press ENTER to begin the PoS Port Monitor. Press 1 to use the PoS default settings, or press 2 to enter the settings.

USE POS DEFALTS? 1-YES 2-NO
INCOMING DATA...

Note: If 2 is pressed, see below for settings to select. Press ENTER to exit.

SELECT BAUD RATE 9600 }{
SELECT STOP BITS 1 {

Consult the PoS system manual for specific Baud Rate and Stop Bits as needed.
Press the Up and Down Arrow keys to select the appropriate Baud Rate, and then press ENTER. Default Baud Rate = 9600
Press the Up and Down Arrow keys to select the appropriate Stop Bits, and then press ENTER. Default Stop Bits = 1

DIAGNOSTICS COM PORT TESTS

Press ENTER to test the operation of the DM-100 COM ports and/or cables. These tests are useful for determining if the ports themselves are operational and if cables are good.

SELECT TEST } RS232 COM0
SELECT TEST {} RS232 COM0]COM1
SELECT TEST {} RS232 COM1
SELECT TEST { CURRENT LOOP

Press the Up and Down Arrow keys to select the appropriate test, and then press ENTER.
· RS232 COM0 ­ Checks for a "loopback" jumper on pins 2 & 3 of the topleft connector (FAIL if a loopback is not detected).
· RS232 COM0->COM1 ­ Checks for transmit and receive connections between the top-left and top-right connectors (FAIL if the ports are not connected together).
· RS232 COM1 ­ Checks for a "loopback" jumper on pins 2 & 3 of the topright connector (FAIL if a loopback is not detected).
· CURRENT LOOP ­ Checks for "loopback" jumpers on the left connector between pins 6 & 8 and 5 & 9 (FAIL if jumpers not detected).

Press ENTER to exit.

DIAGNOSTICS POS STATUS

This menu is only used for internal Daktronics testing purposes.

DD2294807 Rev 04 14 September 2022

201 Daktronics Drive Brookings, SD 57006-5128 www.daktronics.com/support
800.325.8766

Configuring the DM-100 Gen III for Sapphire Interface Quick Guide

Page 4 of 8

About
1. Press the MENU key followed by ENTER to select the Diagnostics Menu. 2. Press the Down Arrow key to reach About, and then press ENTER.

ABOUT ENT TO VIEW

LCD Screen

Action/Information Shown

ABOUT ] FIRMWARE DD-2256160 4.9
ABOUT ] FUNCTION GAS PRICE

Press ENTER to view the About menu. The DM-100 toggles between Firmware and Function information. Press ENTER at any time to exit the About menu.

Display Menu
1. Press the MENU key. 2. Press the Down Arrow key to reach Display Menu. 3. Press ENTER to select the Display Menu.
Price Options
1. Press the MENU key. 2. Press the Down Arrow key to reach Display Menu, and then press ENTER. 3. Press ENTER to open the Price Options menu item.

DISPLAY MENU ENT TO BEGIN
PRICE OPTIONS ENT TO SELECT

LCD Screen

Action/Information Shown

ACTIVE PRICES

123

{}

ACTIVE PRICES

23

{}

ACTIVE PRICES

1 3

{}

ACTIVE PRICES

3

{}

ACTIVE PRICES

12

{}

ACTIVE PRICES

2

{}

ACTIVE PRICES

1

{}

The ACTIVE PRICES menu is used to select the active price states (Cash, Credit, and/or Debit) to show on the display along with a hold time for each active price.
Note: If there is no CASH/CREDIT display, the ACTIVE PRICES menu selection should be set to "1" to only show one price.
This menu works with the PoS Price Offset (p.6) menu. VAL1, VAL2, and VAL3 are the adjustments to be applied when showing price 1, 2, and 3, respectively.
Press the Up and Down Arrow keys to cycle between active price choices: 123, _23, 1_3, _ _3, 12_, _2_, 1_ _
Press ENTER, and then use the number keypad to enter the HOLD TIME in seconds for each active price to be displayed. Press ENTER to save the active prices and hold time.
Note: The default hold time is 3 seconds.

SET HOLD TIME 3.0*

DD2294807 Rev 04 14 September 2022

201 Daktronics Drive Brookings, SD 57006-5128 www.daktronics.com/support
800.325.8766

Configuring the DM-100 Gen III for Sapphire Interface Quick Guide

Page 5 of 8

Configuration
1. Press the MENU key. 2. Press the Down Arrow key to reach Display Menu, and then press ENTER. 3. Press the Down Arrow key to reach Configuration, and then press ENTER.

CONFIGURATION ENT TO SELECT

LCD Screen

Action/Information Shown

CONFIGURATION LINE MAPPING }

SELECT NETWORK

X

{}

SELECT DISPLAY ADDRESS XX {}

ENT TO COMMIT ADR XX LIN 0X{}

UPDATING DISPLAYS...

Press ENTER to begin editing line information.
Note: The line in Edit mode flashes and shows its line information (L01, L02, etc.)
Press the Up Arrow key to select another network, if applicable, and then press ENTER.
Press the Up and Down Arrow keys to select a sign address, and then press ENTER.
Press the Up and Down Arrow keys to change the Line Number. Press ENTER to accept the Address and Line assignments.
Press CLEAR/SET FUNCTION to map lines in the next network. Continue pressing CLEAR/SET FUNCTION to exit to the main screen.

CONFIGURATION STYLE {
SELECT STYLE NO TAILS 9/10 {} SELECT STYLE TAILS 9/10 {} SELECT STYLE NO TAILS 9 {} SELECT STYLE TAILS 9 {}

Press ENTER to change the appearance of numbers six and nine (6 and 9). Figure 1 shows examples.
Note: For Domestic displays with a 9/10 digit, the number "3" must show in the first column for the desired format. For International displays, make sure the number "4" appears in the first column for the desired format.
Press the Up and Down Arrow keys to toggle through the choices: · Remove tails on sixes and nines, and show 9/10 on the display. · Show tails on sixes and nines, and show 9/10 on the display. · Remove tails from sixes and nines and show only a 9 on the display. · Show tails on sixes and nines, and show only a 9 on the display.
Press the ENTER key to view the change.
Press CLEAR/SET FUNCTION to save the selection.

No Tails and 9/10 Tails and 9/10

No Tails and 9

Tails and 9

Figure 1: Digit Configuration Styles

DD2294807 Rev 04 14 September 2022

201 Daktronics Drive Brookings, SD 57006-5128 www.daktronics.com/support
800.325.8766

Configuring the DM-100 Gen III for Sapphire Interface Quick Guide

Page 6 of 8

PoS Settings
1. Press the MENU key. 2. Press the Down Arrow key to reach Display Menu, and then press ENTER. 3. Press the Down Arrow key to reach PoS Settings, and then press ENTER.

POS SETTINGS ENT TO MODIFY

LCD Screen
POS INTERFACE SAPPHIRE {}
LINE 1 PRODUCT: XX{}

Action/Information Shown Use the Up and Down Arrow keys to select SAPPHIRE, and then press ENTER. Each price is identified by product ID. Use the Up and Down Arrow keys to select a product ID for line 1, and then press ENTER. If a line is not used, select NONE. Complete the steps above for each display line.

PoS Price Offset
1. Press the MENU key.

POS PRICE OFFSET ENT TO MODIFY

2. Press the Down Arrow key to reach Display Menu, and then press ENTER.

3. Press the Down Arrow key to reach PoS Price Offset, and then press ENTER.

LCD Screen

Action/Information Shown

Use the Up and Down Arrow keys to select the amount to offset the price (in cents).

LN1 PRICE OFFSET VAL1 +.00 {}

Press ENTER to move to the next value to offset.
Complete the steps above for each value of every line. Up to three offset values (VAL1, VAL2, VAL3) may be configured. The adjustments are applied when showing price 1, 2, and/or 3 as described in Price Options (p.4).

Note: This is for use with CASH/CREDIT displays. If there is no CASH/CREDIT display, "VAL1" should be set to "+.00".

PRICE OFFSETS NOT ALLOWED

If this message appears, a PoS interface has not been properly configured. Refer to PoS Settings (p.6) to ensure the correct PoS interface is selected.

DD2294807 Rev 04 14 September 2022

201 Daktronics Drive Brookings, SD 57006-5128 www.daktronics.com/support
800.325.8766

Configuring the DM-100 Gen III for Sapphire Interface Quick Guide

Page 7 of 8

Modem
1. Press the MENU key. 2. Press the Down Arrow key to reach Display Menu, and then press ENTER. 3. Press the Down Arrow key to reach Modem, and then press ENTER.

MODEM ENT TO SELECT

LCD Screen
Modem Select: Enabled Modem Select: Disabled
Save? ENTER:YES CLEAR: NO

Action/Information Shown Use the Up and Down Arrow keys to select whether to enable or disable the modem.
Press ENTER.
Press ENTER again to save the selection or press CLEAR to cancel.

Dimming
1. Press DIMMING on the keypad. The current setting is shown on the bottom line of the LCD. The dimming level of the display is adjusted in one of two ways:
· Automatic Dimming uses a light sensor inside each display to detect the level of ambient light at the display location and dim the LED brightness accordingly.
· Manual Dimming retains the same LED brightness level regardless of the level of light detected at the display.
2. Refer to the following tables to set the dimming level:

LCD Screen
DIMMING AUTOMATIC }

Action/Information Shown
Press the Down Arrow key to toggle through dimming settings: · Automatic ­ The display automatically dims based on the light detected
at the display. · Manual ­ The display dimming level is set manually. Once set, this value
remains the same regardless of the light level detected at the display. · Blank Sign ­ Briefly clears all content from display.

When MANUAL dimming is selected, the following prompt appears:

LCD Screen

Action/Information Shown

INTENSITY XX}{* ENTER TO SET

Press the Up and Down Arrow keys to modify the display's current intensity. Note: The DM-100 must be communicating with the display.

XX ­ Current intensity (01-63) Press ENTER to accept this intensity. Max Intensity ­ 63

DD2294807 Rev 04 14 September 2022

201 Daktronics Drive Brookings, SD 57006-5128 www.daktronics.com/support
800.325.8766

Configuring the DM-100 Gen III for Sapphire Interface Quick Guide

Page 8 of 8

When BLANK SIGN is selected, the following prompt appears:

LCD Screen
BLANK THE SIGN? <ENT> YES
BLANK THE SIGN? <CLR> NO
RESTART SIGN? <ENT> YES
RESTART SIGN? <CLR> NO

Action/Information Shown Press ENTER to blank the sign. Press CLEAR to leave the sign on. When in Blank Mode, the digits on all of the displays will turn off and only the decimal will be lit. To turn the sign back on, first press the DIMMING key, and then press ENTER. To leave the sign blank, press CLEAR.

Set Petroleum Prices
Each line automatically updates when the price is changed in the PoS system. The following error appears when attempting to edit prices that are configured for PoS control:

LCD Screen

Action/Information Shown

THIS PRICE POS CTRLD. OVERRIDE?

To manually edit the price, press ENTER. To cancel, press CLEAR.

Update the Display
After connecting to the display with the handheld controller, press UPDATE DISPLAY to show the new sequence on the display. This button also allows for a preview of the new sequence on the LCD.

For More Information

Contact Daktronics Customer Service:

United States & Canada: 1-800-DAK-TRON (325-8766)

Outside the U.S. & Canada: +1-605-275-1040

For additional information and assistance, contact VeriFone at 800-VeriFone (800-837-4366).

DD2294807 Rev 04 14 September 2022

201 Daktronics Drive Brookings, SD 57006-5128 www.daktronics.com/support
800.325.8766



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Windows)