Report No.: BL-SZ2460066-605 TEST REPORT Applicant: Address: Equipment Type: Model Name: Brand Name: FCC ID: Test Standard: Sample Arrival Date: Test Date: Date of Issue: Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China Mobile Phone RMX3951 realme 2AUYFRMX3951 47 CFR Part 15 Subpart E (refer to section 3.1) Jun. 03, 2024 Jun. 04, 2024 - Jun. 05, 2024 Jul. 04, 2024 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Si Xiao Checked by: Ye Hongji Approved by: Liao Jianming (Technical Director) _______________ _______________ _______________ Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 1 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 Version Rev. 01 Issue Date Jul. 04, 2024 Revision History Revisions Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................... 4 1.1 Test Laboratory .............................................................................................................. 4 1.2 Test Location.................................................................................................................. 4 2 PRODUCT INFORMATION ......................................................................................................... 5 2.1 Applicant Information...................................................................................................... 5 2.2 Manufacturer Information ............................................................................................... 5 2.3 General Description for Equipment under Test (EUT) ................................................... 5 2.4 Technical Information ..................................................................................................... 6 3 SUMMARY OF TEST RESULTS................................................................................................. 7 3.1 Test Standards ............................................................................................................... 7 3.2 Test Verdict .................................................................................................................... 7 3.3 Measurement Uncertainty .............................................................................................. 7 4 GENERAL TEST CONFIGURATIONS ........................................................................................ 8 4.1 Test Environments ......................................................................................................... 8 4.2 Test Equipment List........................................................................................................ 8 4.3 Test Software List........................................................................................................... 8 4.4 Description of Test Setup ............................................................................................... 9 5 TEST ITEMS.............................................................................................................................. 10 5.1 DFS .............................................................................................................................. 10 ANNEX A TEST RESULT ............................................................................................................. 20 A.1 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME....................... 20 A.2 NON-OCCUPANCY PERIOD ...................................................................................... 24 ANNEX B TEST SETUP PHOTOS ............................................................................................... 26 ANNEX C EUT EXTERNAL PHOTOS .......................................................................................... 26 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 2 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 ANNEX D EUT INTERNAL PHOTOS ........................................................................................... 26 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 3 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 1 GENERAL INFORMATION 1.1 Test Laboratory Name Address Phone Number Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China +86 755 6685 0100 1.2 Test Location Name Location Accreditation Certificate Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China The laboratory is a testing organization accredited by FCC as a accredited testing laboratory. The designation number is CN1196. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 4 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Address Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China 2.2 Manufacturer Information Manufacturer Address Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China 2.3 General Description for Equipment under Test (EUT) EUT Name Model Name Under Test Series Model Name Description of Model name differentiation Hardware Version Software Version Dimensions (Approx.) Weight (Approx.) EUT ID IMEI Number Mobile Phone RMX3951 N/A N/A 11 realme UI 5.0 about 165.6×76.1×7.79(mm) about 190g S38 S38: IMEI1: 862456070034278 IMEI2:862456070034260 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 5 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 2.4 Technical Information 2G Network GSM/GPRS/EDGE 850/1900 MHz 3G Network WCDMA/HSDPA/HSUPA/HSPA+ Band 2/4/5 4G Network LTE FDD Band 2/4/5/7/12/13/17/26/66 LTE TDD Band 38/41 LTE CA Uplink (UL): CA_7C, CA_38C, CA_41C LTE Downlink (DL): CA_2C, CA_7B, CA_7C, CA_38C, CA_41C, CA_41A-41A, CA_7A-7A, CA_2A-38A, CA_5A-41A, CA_5A-66A, CA_7A-66A, CA_2A-2A, CA_2A-5A, CA_2A-7A, CA_2A-12A, CA_4A-5A, CA_4A-7A, CA_5A-7A, CA_12A-66A, CA_66A-66A, CA_4A-4A, CA_26A-41A, CA_5A-38A, CA_2A-4A, CA_38A-66A, CA_26A-38A, CA_2A-66A, CA_7A-26A 5G Network Network and Wireless connectivity SA: NR n5/n7/n38/n41/n66 NSA UL (EN-DC): DC_7A_n5A, DC_66A_n5A, DC_2A_n7A, DC_4A_n7A, DC_5A_n7A, DC_7A_n7A, DC_66A_n7A, DC_2A_n66A, DC_5A_n66A, DC_7A_n66A, DC_66A_n66A, DC_2A_n38A, DC_4A_n38A, DC_5A_n38A, DC_38A_n38A, DC_66A_n38A, DC_2A_n41A, DC_4A_n41A, DC_26A_n41A, DC_41A_n41A, DC_66A_n41A DL(EN-DC): DC_7C_n5A, DC_7C_n66A, DC_5A-66A_n66A, DC_7A-66A_n66A, DC_2A-5A_n66A, DC_5A-7A_n7A, DC_5A- 7A_n66A, DC_66A-66A_n5A, DC_66A-66A_n7A NR CA Downlink (DL): CA_n5A-n7A, CA_n7B Bluetooth (BR+EDR+BLE) 2.4G WIFI 802.11b, 802.11g, 802.11n(HT20/40) and VHT(20/40) 5G WIFI 802.11a, 802.11n(HT20/40) and 802.11ac(VHT20/40/80) U-NII-1/2A/2C/3, GPS, GLONASS, BDS, Galileo, NFC The requirement for the following technical information of the EUT was tested in this report: Frequency Range 5250 MHz to 5350 MHz, 5470 MHz to 5725 MHz Mobile Product Type Portable Fix Location Maximum Output Power 5250 MHz to 5350 MHz: 32.06 mW 5470 MHz to 5725 MHz: 13.65 mW Antenna Type IFA Antenna Antenna Gain 5250 MHz to 5350 MHz: -1.56 dBi 5470 MHz to 5725 MHz: -0.10 dBi Note: This device (Client) is without radar detection, then the manufacturer statement confirming that information regarding the parameters of the detected Radar Waveforms is not available to the end user. And the device doesn't have Ad Hoc mode on DFS frequency band. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 6 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 3 SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 47 CFR Part 15 Subpart E Unlicensed National Information Infrastructure Devices 2 KDB Publication 905462 D02v02 UNII DFS Compliance Procedures New Rules 3 KDB Publication 905462 D03v01r02 UNII Clients Without Radar Detection New Rules 4 KDB Publication 789033 D02v02r01 Guidelines for Compliance Testing of Unlicensed National Information Infrastructure (U-NII) Devices Part 15, Subpart E 3.2 Test Verdict No. Description 1 Channel Move Time 2 Channel Closing Transmission Time 3 Non- Occupancy Period FCC Part No. 15.407 15.407 15.407 Verdict Pass Pass Pass Remark Applicable Applicable Applicable 3.3 Measurement Uncertainty The following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2.This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Parameters Occupied Channel Bandwidth RF output power, conducted Power Spectral Density, conducted Unwanted Emissions, conducted All emissions, radiated Temperature Humidity Uncertainty 2.8% 1.28 dB 1.30 dB 1.84 dB 5.36 dB 0.8°C 4% Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 7 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 4 GENERAL TEST CONFIGURATIONS 4.1 Test Environments During the measurement, the normal environmental conditions were within the listed ranges: Relative Humidity Atmospheric Pressure Temperature Working Voltage of the EUT 61% to 67% 100 kPa to 102 kPa NT (Normal Temperature) LT (Low Temperature) HT (High Temperature) NV (Normal Voltage) LV (Low Voltage) HV (High Voltage) +22.1 to +22.9 0.0 +35 3.89 V 3.40 V 4.48 V 4.2 Test Equipment List Description Spectrum Analyzer Signaling Unit Vector Signal Generator Signal Generator Switch Unit with OSPB157 Manufacturer ROHDE&SCHWARZ ROHDE&SCHWARZ Model FSV-40 CMW270 ROHDE&SCHWARZ SMBV100A ROHDE&SCHWARZ SMB100A ROHDE&SCHWARZ OSP120 Serial No. 101544 100607 260592 177746 101270 Cal. Date 2023.12.27 2024.05.08 2023.12.27 2024.05.08 2024.05.08 Cal. Due 2024.12.26 2025.05.07 2024.12.26 2025.05.07 2025.05.07 Master Access Point Brand Name Model No. Serial No. FCC ID SPEC. ASUS RT-AC66U GBICGG000668 MSQ-RTAC66U The maximum EIRP is18.5dBm, Antenna Gain is 6.57dBi 4.3 Test Software List Description BL410R Manufacturer BALUN Software Version V2.1.1.488 Serial No. N/A Applicable test Setup The section 4.4.1 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 8 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 4.4 Description of Test Setup 4.4.1 Conducted Test Setup Configuration Client without Radar Detection Mode The UUT is a U-NII Device operating in Client mode without radar detection. The radar test signals are injected into the Master Device. (Diagram 1) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 9 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 5 TEST ITEMS 5.1 DFS 5.1.1 U-NII DFS Rule Requirements 5.1.1.1 Working Mode and Required Test Items The manufacturer shall state whether the UUT is capable of operating as a Master and/or a Client. If the UUT is capable of operating in more than one operating mode then each operating mode shall be tested separately. See tables 1 and 2 for the applicability of DFS requirements for each of the operational modes. APPLICABILITY OF DFS REQUIREMENTS PRIOR TO USE A CHANNEL Requirement Non-Occupancy Period DFS Detection Threshold Channel Availability Check Time Uniform Spreading U-NII Detection Bandwidth Master Operational Mode Client without radar detection Not required Not required Not required Not required Client with radar detection Not required Not required APPLICABILITY OF DFS REQUIREMENTS DURING NORMAL OPERATION Requirement DFS Detection Threshold Channel Closing Transmission Time Channel Move Time U-NII Detection Bandwidth Master Operational Mode Client without radar Client with radar detection detection Not required Not required Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 10 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 5.1.2Test Limits and Radar Signal Parameters Detection Thereshold Values DFS DETECTION THRESHOLDS FOR MASTER DEVICES AND CLIENT DEVICES WITH RADAR DETECTION Maximum Transmit Power Value (See Note 1 & 2) 200 milliwatt -64 dBm < 200 milliwatt -62 dBm Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna. Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test transmission waveforms to account for variations in measurement equipment. This will ensure that the test signal is at or above the detection threshold level to trigger a DFS response. DFS RESPONSE REQUIREMENT VALUES Parameter Value Non-occupancy period Minimum 30 minutes Channel Availability Check Time 60 seconds Channel Move Time 10 seconds See Note 1. Channel Closing Transmission Time 200 milliseconds + an aggregate of 60 milliseconds over remaining 10 second period. See Note 1&2. U-NII Detection Bandwidth 100% of the UNII transmission power bandwidth. See Note 3. Note 1: The instant that the Channel Move Time and the Channel Closing Transmission Time begins is as follows: · For the Short Pulse Radar Test Signals this instant is the end of the Burst. · For the Frequency Hopping radar Test Signal, this instant is the end of the last radar Burst generated. · For the Long Pulse Radar Test Signal this instant is the end of the 12 second period defining the Radar Waveform. Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning of the Channel Move Time plus any additional intermittent control signals required to facilitate a Channel move (an aggregate of 60 milliseconds) during the remainder of the 10 second period. The aggregate duration of control signals will not count quiet periods in between transmissions. Note 3: During the U-NII Detection Bandwidth detection test, radar type 1 is used and for each frequency step the minimum percentage of detection is 90 percent. Measurements are performed with no data traffic. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 11 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 Parameters of DFS Test Signals Step intervals of 0.1 microsecond for Pulse Width, 1 microsecond for PRI, 1 MHz for chirp width and 1 for the number of pulses will be utilized for the random determination of specific test waveforms. SHORT PULSE RADAR TEST WAVEFORMS Radar Type Pulse Width (µsec) PRI (µsec) 0 1 1428 Test A: 15 unique PRI values randomly selected from the list of 23 PRI values in Table 5a Test B: 15 unique PRI values 1 1 randomly selected within the range of 518-3066 sec, with a minimum increment of 1 sec, excluding PRI values selected in Test A 2 1-5 150-230 Number of Pulses 18 23-29 Minimum Percentage Minimum of Successful Number of Detection Trials See Note See Note 60% 30 60% 30 3 6-10 200-500 16-18 60% 30 4 11-20 200-500 12-16 60% 30 Aggregate (Radar Types 1-4) 80% 120 Note: Short Pulse Radar Type 0 should be used for the detection bandwidth test, channel move time, and channel closing time tests. Radar Type 5 LONG PULSE RADAR TEST WAVEFORM Pulse Width (µsec) Chirp Width (MHz) PRI (µsec) Number of Pulses per Burst Number of Bursts Minimum Percentage of Successful Detection 50-100 5-20 1000-2000 1-3 8-20 80% Minimum Number of Trials 30 Radar Type 6 FREQUENCY HOPPING RADAR TEST WAVEFORM Pulse Width (µsec) PRI (µsec) Pulses per Hop Hopping Rate (kHz) Hopping Sequence Length (msec) Minimum Percentage of Successful Detection 1 333 9 0.333 300 70% Minimum Number of Trials 30 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 12 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 5.1.2.1 Test Setup See 4.4 for test setup description for the radiated test. The photo of test setup please refer to ANNEX B. 5.1.2.2 Test Procedure DFS MEASUREMENT SYSTEM: A complete DFS Measurement System consists of two subsystems: (1) the Radar Signal Generating Subsystem and (2) the Traffic Monitoring Subsystem. The control PC is necessary for generating the Radar waveforms in Table 6, 7 and 8. The traffic monitoring subsystem is specified to the type of unit under test (UUT). Conducted setup configuration of ADT DFS Measurement System Control PC Radar Signal Generating Subsystem Spectrum Analyzer Attenuator C/S Attenuator Attenuator C/S Traffic Monitoring Subsystem Support Unit Master / Client with DFS function The test transmission will always be from the Master Device to the Client Device. While the Client device is set up to associate with the Master device and play the MPEG file (6 Magic Hours) from Master device, the designated MPEG test file and instructions are located at: http://ntiacsd.ntia.doc.gov/dfs/. CALIBRATION OF DFS DETECTION THRESHOLD LEVEL: The measured channel is 5500 MHz in 20MHz Bandwidth and 5530MHz in 80MHz Bandwidth. The radar signal was the same as transmitted channels, and injected into the antenna port of AP (master) or Client Device with Radar Detection, measured the channel closing transmission time and channel move time. The Master antenna gain is 6.57dBi and required detection threshold is-54.43dBm (= -62 +1 +6.57)dBm. The calibrated conducted detection threshold level is set to -54.43 dBm. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 13 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 Conducted setup configuration of Calibration of DFS Detection Threshold Level Control PC Spectrum Analyzer 50 Load (Terminator) C/S 50 Load (Terminator) Attenuator Attenuator Radar Signal Generating Subsystem Attenuator C/S Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 14 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 Radar Waveform Calibration Result Radar Type 0 Calibration Plot (5290MHz) Radar Type 1 test A Calibration Plot (5290MHz) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 15 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 Radar Type 1 test B Calibration Plot (5290MHz) Radar Type 2 Calibration Plot (5290MHz) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 16 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 Radar Type 3 Calibration Plot (5290MHz) Radar Type 4 Calibration Plot (5290MHz) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 17 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 Radar Type 5 Calibration Plot (5290MHz) Radar Type 6 Calibration Plot (5290MHz) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 18 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 5.1.2.3 Test Result Please refer to ANNEX A. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 19 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 ANNEX A TEST RESULT A.1 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME Result of DFS Channel Shutdown Note: The radar test signals are injected into the Master Device. This test was investigated for different bandwidth (the lowest and the highest bandwidth). Description Operation Mode Operation Channel Value (s) Limit Channel Move Time 802.11a 52 3.458 10 s Channel Closing 200 milliseconds + an aggregate Transmission 802.11a 52 0.036 of 60 milliseconds over Time remaining 10 second period. Channel Move Time 802.11a 100 3.825 10 s Channel Closing 200 milliseconds + an aggregate Transmission 802.11a 100 0.039 of 60 milliseconds over Time remaining 10 second period. Channel Move Time 802.11ac (80 MHz) 58 3.632 10 s Channel Closing Transmission Time 802.11ac (80 MHz) 58 0.034 200 milliseconds + an aggregate of 60 milliseconds over remaining 10 second period. Channel Move Time 802.11ac (80 MHz) 106 3.710 10 s Channel Closing Transmission Time 802.11ac (80 MHz) 106 0.033 200 milliseconds + an aggregate of 60 milliseconds over remaining 10 second period. Test Verdict Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 20 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 T0 denotes DFS test signal start generated on the channel. T1 denotes the end of the radar burst. T2 denotes the instant when the UUT has ceased all transmissions on the channel. The time difference between T1 and T2 shall be measured. This value (Channel Move Time) shall be noted and compared with the limit. The aggregate duration (Channel Closing Transmission Time) of all transmissions from the UUT on Chr during the Channel Move Time shall be compared to the limit. DFS Test schematic graphic Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 21 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 802.11a Channel 52 Level in dBm 0 -5 -10 -15 -20 -25 -30 -35 0 2 4 6 8 10 12 14 16 18 20 Time in s 802.11a Channel 100 5 0 -10 -20 -30 Level in dBm 0 2 4 6 8 10 12 14 16 18 20 Time in s Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 22 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 802.11ac(80 MHz) Channel 58 Level in dBm -20 -25 -30 -35 0 2 4 6 8 10 12 14 16 18 20 Time in s 802.11ac(80 MHz) Channel 106 Level in dBm -20 -25 -30 -35 0 2 4 6 8 10 12 14 16 18 20 Time in s Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 23 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 A.2 NON-OCCUPANCY PERIOD Master was off. During the 30 minutes observation time, The UUT did not make any transmissions in the DFS band after UUT power up. 802.11a Channel 52 Level in dBm -23 -23.5 -24 -24.5 -25 -25.5 -26 0 802.11a Channel 100 500 1000 Time in s 1500 1860 Level in dBm -22 -23 -24 -25 0 500 1000 Time in s 1500 1860 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 24 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 802.11ac(80 MHz) Channel 58 Level in dBm -23.5 -24 -24.5 -25 -25.5 -26 0 500 802.11ac(80 MHz) Channel 106 1000 Time in s Level in dBm -23 -24 -25 -26 0 500 1000 Time in s 1500 1860 1500 1860 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 25 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 ANNEX B TEST SETUP PHOTOS Please refer the document "BL-SZ2460066-AR.PDF". ANNEX C EUT EXTERNAL PHOTOS Please refer the document "BL-SZ2460066-AW.PDF". ANNEX D EUT INTERNAL PHOTOS Please refer the document "BL-SZ2460066-AI.PDF". Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 26 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-605 Statement 1. The laboratory guarantees the scientificity, accuracy and impartiality of the test, and is responsible for all the information in the report, except the information provided by the customer. The customer is responsible for the impact of the information provided on the validity of the results. 2. The report without China inspection body and laboratory Mandatory Approval (CMA) mark has no effect of proving to the society. 3. For the report with CNAS mark or A2LA mark, the items marked with "" are not within the accredited scope. 4. This report is invalid if it is altered, without the signature of the testing and approval personnel, or without the "inspection and testing dedicated stamp" or test report stamp. 5. The test data and results are only valid for the tested samples provided by the customer. 6. This report shall not be partially reproduced without the written permission of the laboratory. 7. Any objection shall be raised to the laboratory within 30 days after receiving the report. --END OF REPORT-- Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 27 / 27 Web: www.titcgroup.com Template No.: TRP-FCC Part 15.407 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China钛和检测认证集团股份有限公司