BLU Products, Inc. BLUC5LMX175 Smart Phone with GSM, WCDMA, LTE, WiFi and Bluetooth YHLBLUC5LMX175 YHLBLUC5LMX175 bluc5lmx175
REPORT No.SZ23040024E01 TEST REPORT APPLICANT : BLU Products, Inc. PRODUCT NAME : Smart Phone MODEL NAME : C5L MAX BRAND NAME : BLU FCC ID : YHLBLUC5LMX175 STANDARD(S) : 47 CFR Part 15 Subpart B RECEIPT DATE : 2023-04-03 TEST DATE : 2023-04-12 to 2023-05-29 ISSUE DATE : 2023-06-12 Edited by: Chen Bilian(Rapporteur) Approved by: Xiao Xiong(Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 22 REPORT No.SZ23040024E01 DIRECTORY 1. Technical Information 3 1.1. Applicant and Manufacturer Information 3 1.2. Equipment Under Test (EUT) Description 3 2. Test Results 5 2.1. Applied Reference Documents 5 2.2. EUT Setup and Operating Conditions 6 3. 47 CFR Part 15B Requirements 8 3.1. Conducted Emission 8 3.2. Radiated Emission 12 Annex A Test Uncertainty 19 Annex B Testing Laboratory Information 20 Version 1.0 Change History Date 2023-06-12 Reason for Change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 22 1. Technical Information REPORT No.SZ23040024E01 Note: Provide by applicant 1.1. Applicant and Manufacturer Information Applicant: Applicant Address: Manufacturer: Manufacturer Address: BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA 1.2. Equipment Under Test (EUT) Description Product Name: EUT No.: Hardware Version: Software Version: Tx Frequency: Rx Frequency: Smart Phone 7# A507-MB-V3.6D A507-37H_sp9832e_1h10_go2g-userdebug-native_0307_1443 GSM850: 824 MHz ~ 849 MHz GSM1900: 1850 MHz ~ 1910 MHz WCDMA Band II: 1850 MHz ~ 1910 MHz WCDMA Band IV: 1710 MHz ~ 1755 MHz WCDMA Band V: 824 MHz ~ 849 MHz LTE Band 2: 1850 MHz ~ 1910 MHz LTE Band 4: 1710 MHz ~ 1755 MHz LTE Band 5: 824 MHz ~ 849 MHz LTE Band 7: 2500 MHz ~ 2570 MHz LTE Band 12: 699 MHz ~ 716 MHz LTE Band 17: 704 MHz ~ 716 MHz LTE Band 66: 1710 MHz ~ 1780 MHz LTE Band 71: 663 MHz ~ 698 MHz 802.11b/g/n: 2412 MHz ~ 2472 MHz Bluetooth: 2402 MHz ~ 2480 MHz GSM850: 869 MHz ~ 894 MHz GSM1900: 1930 MHz ~ 1990 MHz WCDMA Band II: 1930 MHz ~ 1990 MHz WCDMA Band IV: 2110 MHz ~ 2155 MHz WCDMA Band V: 869 MHz ~ 894 MHz LTE Band 2: 1930 MHz ~ 1990 MHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 22 REPORT No.SZ23040024E01 Accessory: Note: LTE Band 4: 2110 MHz ~ 2155 MHz LTE Band 5: 869 MHz ~ 894 MHz LTE Band 7: 2620 MHz ~ 2690 MHz LTE Band 12: 729 MHz ~ 746 MHz LTE Band 17: 734 MHz ~ 746 MHz LTE Band 66: 2110 MHz ~ 2200 MHz LTE Band 71: 617 MHz ~ 652 MHz 802.11b/g/n: 2412 MHz ~ 2472 MHz Bluetooth: 2402 MHz ~ 2480 MHz GPS/GLONASS/BDS/Galileo: 1559 MHz ~1610 MHz FM: 87.5 MHz ~108 MHz AC Adapter Brand Name: BLU Model No.: US-JY-1000 Serial No.: (N/A, marked #1 by test site) Rated Input: 100-240V 50/60Hz, 0.3A Rated Output: 5V 1000mA Manufacturer: Battery Dongguan Jieyuan Electronic Technology Co., LTD Brand Name: BLU Model No.: C775444200L Serial No.: (N/A, marked #1 by test site) Capacity: 2000mAh Rated Voltage: 3.8V Charge Limit: 4.35V Manufacturer: Shenzhen Aerospace Electronic Co.,Ltd. 1. For a more detailed description, please refer to specification or user's manual supplied by the applicant and/or manufacturer. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 22 REPORT No.SZ23040024E01 2. Test Results 2.1. Applied Reference Documents The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B: No. Identity 1 47 CFR Part 15 Document Title Radio Frequency Devices Test detailed items/section required by FCC rules and results are as below: No. Section Description Test Date 1 15.107 Conducted Emission 2023.04.12 2 15.109 Radiated Emission 2023.05.29 Test Engineer Result Fan Zehang PASS Yang Lian PASS Method Determination Remark No deviation No deviation Note 1:The tests were performed according to the method of measurements prescribed in ANSI C63.4-2014. Note 2:Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3:When the test result is a critical value,we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 22 REPORT No.SZ23040024E01 2.2. EUT Setup and Operating Conditions Note: All of the following test modes are tested in all the test items. Test Item Mode 1 : EUT + GSM850 Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 2 : EUT + GSM1900 Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 3 : EUT + WCDMA Band II Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 4 : EUT + WCDMA Band IV Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 5 : EUT + WCDMA Band V Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 6 : EUT + LTE Band 2 Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 7 : EUT + LTE Band 4 Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 8 : EUT + LTE Band 5 Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 9 : EUT + LTE Band 7 Idle + Bluetooth Idle + 2.4G WLAN Idle + GPS Rx +AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 10 : EUT + LTE Band 12 Idle + Bluetooth Idle + 2.4G WLAN Idle + GLONASS Rx + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 11 : EUT + LTE Band 17 Idle + Bluetooth Idle + 2.4G WLAN Idle + BDS Rx +AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 12 : EUT + LTE Band 66 Idle + Bluetooth Idle + 2.4G WLAN Idle + Galileo Rx +AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 13 : EUT + LTE Band 71 Idle + Bluetooth Idle + 2.4G WLAN Idle + FM Rx + AC Adapter + Battery + USB Cable + Earphone + SIM Card Mode 14 : EUT + LTE Band 2 Idle + Bluetooth Idle + 2.4G WLAN Idle + AC Adapter + Battery + USB Cable + Earphone + SIM Card + Rear camera mode Mode 15 : EUT + LTE Band 12 Idle + Bluetooth Idle + 2.4G WLAN Idle + Battery + USB Cable + Earphone + SIM Card + PC + PC Adapter + Data Transmission Mode Remark: The above test mode in boldface (Mode 14) was the worst case of conducted emission test, only the test data of these modes were reported. The above test mode in boldface (Mode 15) was the worst case of radiated emission test, only the test data of these modes were reported. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 22 REPORT No.SZ23040024E01 During the measurement, the environmental conditions were within the listed ranges: Temperature (°C): Relative Humidity (%): Atmospheric Pressure (kPa): 15 - 35 30 - 60 86 - 106 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 22 REPORT No.SZ23040024E01 3. 47 CFR Part 15B Requirements 3.1. Conducted Emission 3.1.1. Requirement According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range Conducted Limit (dBµV) (MHz) Quasi-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 NOTE: a) The limit subjects to the Class B digital device. b) The lower limit shall apply at the band edges. c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 3.1.2. Test Setup Please refer to Annex A for the photographs of the Test Configuration. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 22 REPORT No.SZ23040024E01 The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor, and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains through a LISN which provides 50/50µH of coupling impedance for the measuring instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole test system are calibrated to correct the reading. The power strip or extension cord has been investigated to make sure that the LISN integrity inma intained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014 at Clause 4.3. 3.1.3. Test Result Set RBW=9 kHz, VBW=30 kHz. The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average (AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. All test modes are considered, refer to recorded points and plots below. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 22 A. Test Plot and Suspicious Points: REPORT No.SZ23040024E01 (Plot A:L Phase) No. Fre. (MHz) Emission Level (dBµV) Limit (dBµV) Quasi-peak Average Quasi-peak Average Power-line Verdict 1 0.1592 49.85 30.38 65.51 55.51 PASS 2 0.2041 47.23 29.60 63.44 53.44 PASS 3 0.2132 4 0.2436 44.77 42.46 29.33 28.50 63.08 61.97 53.08 51.97 PASS Line PASS 5 0.3808 33.93 25.38 58.26 48.26 PASS 6 0.5805 40.72 35.18 56.00 46.00 PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 22 REPORT No.SZ23040024E01 (Plot B: N Phase) No. Fre. (MHz) Emission Level (dBµV) Limit (dBµV) Quasi-peak Average Quasi-peak Average Power-line Verdict 1 0.1815 44.51 32.98 64.42 54.42 PASS 2 0.5570 46.22 34.98 56.00 46.00 PASS 3 0.5907 4 0.7496 49.10 40.06 38.06 31.09 56.00 56.00 46.00 46.00 Neutral PASS PASS 5 1.1326 39.31 29.70 56.00 46.00 PASS 6 1.2542 38.40 29.42 56.00 46.00 PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 22 3.2. Radiated Emission REPORT No.SZ23040024E01 3.2.1. Requirement According to FCC section 15.109 (a), the field strength of radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following values: Frequency Range (MHz) 30.0 - 88.0 88.0 - 216.0 216.0 - 960.0 Above 960.0 Field Strength Limitation at 3m Measurement Dist (µV/m) (dBµV/m) 100 20log 100 150 20log 150 200 20log 200 500 20log 500 As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength limits are based on average detector. When average radiated emission measurements are specified in this part, including emission measurements below 1000MHz, there also is a limit on the radio frequency emissions, as measured using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit for the frequency being investigated unless a different peak emission limit is otherwise specified in the rules. Note: 1) The tighter limit shall apply at the boundary between two frequency range. 2) Limitation expressed indBµV/m is calculated by 20log Emission Level(µV/m). 3.2.2. Frequency Range of Measurement According to 15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the following table: MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 22 3.2.3. Test Setup 1) For radiated emissions from 30MHz to1GHz REPORT No.SZ23040024E01 2) For radiated emissions above 1GHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 22 REPORT No.SZ23040024E01 The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating Turn Table, and keeps 3m away from the Test Antenna, which is mounted on variable-height antenna master tower. For the test Antenna: In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test Antenna (above 1GHz)are used. Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. The emission levels at both horizontal and vertical polarizations should be tested. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. For measurements below 1GHz the resolution bandwidth is set to 120 kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video bandwidth is set to 3MHz for peak measurements and as applicable for average measurements. 3.2.4. Test Result The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels more than the limits, and that have narrow margins from the limits will be re-measured with AV and QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered to perform the tests. All test modes are considered, refer to recorded points and plots below. The amplitude of emissions which (6GHz-13.5GHz) are attenuated more than 20 dB below the permissible value need not be reported. Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis test condition was recorded in this test report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 22 REPORT No.SZ23040024E01 (Plot A: ANT-Vertical,30MHz - 1GHz) Fre. PK QP AV Limit-PK Limit-QP Limit-AV No. ANT Verdict MHz dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m 1 37.7616 25.33 N.A N.A N.A 40.00 N.A V PASS 2 56.3893 26.39 N.A N.A N.A 40.00 N.A V PASS 3 145.6471 34.03 N.A N.A N.A 43.50 N.A V PASS 4 197.4555 37.58 N.A N.A N.A 43.50 N.A V PASS 5 216.0832 35.59 N.A N.A N.A 46.00 N.A V PASS 6 479.9760 36.11 N.A N.A N.A 46.00 N.A V PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 22 REPORT No.SZ23040024E01 (Plot B: ANT-Vertical,1GHz - 6GHz) Fre. PK QP AV Limit-PK Limit-QP Limit-AV No. ANT Verdict MHz dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m 1 1924.1848 41.86 N.A N.A 74.00 N.A 54.00 V PASS 2 2639.3279 44.13 N.A N.A 74.00 N.A 54.00 V PASS 3 4713.7427 50.16 N.A 30.52 74.00 N.A 54.00 V PASS 4 5388.8778 52.20 N.A 31.51 74.00 N.A 54.00 V PASS 5 5529.9060 52.67 N.A 31.51 74.00 N.A 54.00 V PASS 6 5879.9760 51.87 N.A 32.14 74.00 N.A 54.00 V PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 22 REPORT No.SZ23040024E01 (Plot C:ANT- Horizontal, 30MHz - 1GHz) Fre. PK QP AV Limit-PK Limit-QP Limit-AV No. ANT Verdict MHz dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m 1 58.5237 26.69 N.A N.A N.A 40.00 N.A H PASS 2 159.2298 31.88 N.A N.A N.A 43.50 N.A H PASS 3 198.2316 36.19 N.A N.A N.A 43.50 N.A H PASS 4 249.0698 35.75 N.A N.A N.A 46.00 N.A H PASS 5 271.5783 36.54 N.A N.A N.A 46.00 N.A H PASS 6 479.9760 40.69 N.A N.A N.A 46.00 N.A H PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 22 REPORT No.SZ23040024E01 (Plot D:ANT- Horizontal, 1GHz - 6GHz) Fre. PK QP AV Limit-PK Limit-QP Limit-AV No. ANT Verdict MHz dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m 1 2040.2080 42.61 N.A N.A 74.00 N.A 54.00 H PASS 2 3345.4691 45.79 N.A N.A 74.00 N.A 54.00 H PASS 3 4368.6737 49.94 N.A 29.10 74.00 N.A 54.00 H PASS 4 4913.7828 50.35 N.A 30.48 74.00 N.A 54.00 H PASS 5 5482.8966 51.37 N.A 31.72 74.00 N.A 54.00 H PASS 6 5832.9666 52.15 N.A 32.73 74.00 N.A 54.00 H PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 22 Annex A Test Uncertainty REPORT No.SZ23040024E01 The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. Uncertainty of Conducted Emission Measurement Measuring Uncertainty for a Level of Confidence of 95%(U=2Uc(y)) 9kHz-150kHz 150kHz-30MHz ±3.3dB ±2.8dB Uncertainty of Radiated Emission Measurement Measuring Uncertainty for a Level of Confidence of 95%(U=2Uc(y)) 30MHz-200MHz 200MHz-1000MHz 1GHz-6GHz 6GHz-18GHz ±5.06dB ±5.04dB ±5.18dB ±5.48dB MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 22 REPORT No.SZ23040024E01 Annex B Testing Laboratory Information 1. Identification of the Responsible Testing Laboratory Laboratory Name: Laboratory Address: Telephone: Facsimile: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 2. Identification of the Responsible Testing Location Name: Address: 3. Accreditation Certificate Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Accredited Testing Laboratory: 4. Test Software Utilized Model TS+ -[JS32-RE] TS+ -[ JS32-CE] The FCC designation number is CN1192. Test firm registration number is 226174. (Shenzhen Morlab Communications Technology Co., Ltd.) Version Number Version 2.5.0.6 Version 2.5.0.0 Producer Tonscend Tonscend MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 22 REPORT No.SZ23040024E01 5. Test Equipments Utilized Description Bi-Log Antenna Bi-Log Antenna Horn Antenna Horn Antenna Receiver Receiver 6db Attenuator Preamplifier Preamplifier RF Coaxial Cable RF Coaxial Cable RF Coaxial Cable RF Coaxial Cable RF Coaxial Cable RF Coaxial Cable RF Coaxial Cable Receiver LISN 10dB Pulse Limiter System Simulator Model VULB 9163 VULB 9163 BBHA 9120D BBHA 9120D N9038A N9038A BW-N6W5+ S020180L3203 S10M100L3802 Serial No. 9163-274 9163-519 9120D-963 01774 MY541300 16 MY564000 93 E191001 61171/611 72 46732 PE330 MRE001 CLU18 MRE002 CLU18 MRE003 QA360-40-KK0.5 QA360-40-KKF -2 QA500-18-NN5 22290045 22290046 22120181 BNC MRE04 ESPI NSLK 8127 VTSD 9561-F 101052 8127449 VTSD 9561 F-B #206 CMW500 152038 Manufacturer SCHWARZBECK SCHWARZBECK SCHWARZBECK SCHWARZBECK Agilent KEYSIGHT Mini-circuits LUCIX CORP. LUCIX CORP. Pasternack Pasternack Pasternack Qualwave Qualwave Qualwave Qualwave R&S Schwarzbeck SCHWARZBECK R&S Cal. Date 2022/11/7 2022/5/25 2022/5/25 2022/7/13 2022/7/7 2023/2/9 2022/10/11 2022/7/8 2022/7/8 N/A N/A N/A N/A N/A N/A N/A 2022/7/7 2023/2/21 2022/7/6 2022/10/11 Due. Date 2025/11/6 2025/5/24 2025/5/24 2025/7/12 2023/7/6 2024/2/8 2023/10/10 2023/7/7 2023/7/7 N/A N/A N/A N/A N/A N/A N/A 2023/7/6 2024/2/20 2023/7/5 2023/10/10 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 22 REPORT No.SZ23040024E01 6. Ancillary Equipment Utilized Description earphone Manufacturer Oppo Model N/A Serial No. N/A END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 22Acrobat Distiller 11.0 (Windows)