User Manual for SIEMENS models including: ZN-34US, ZN-34UA, ZN-34UA Gate Valve Supervision Module, Gate Valve Supervision Module, Valve Supervision Module, Supervision Module, Module
Siemens ZN-34US ZN-34UA Gate Valve Supervision Modules, Installation Instructions - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 2 Pages, 641.93KB
DocumentDocumentInstallation Instructions Models ZN-34US and ZN-34UA Gate Valve Supervision Modules Description The Sprinkler Valve Supervision Modules, Model ZN34US and Model ZN-34UA, are designed to provide two circuits for the supervision of sprinkler system gate valves and ancillary equipment in accordance with NFPA Standard 72. The module provides two yellow LED indicators per circuit. The first illuminates when a supervisory condition exists and the second when a circuit trouble condition occurs. The module utilizes an end-of-line resistor in parallel with normally open switches to provide this supervision. The Model ZN-34US provides annunciation of conditions as follows; when a sprinkler valve is closed the supervisory circuit is shorted, the yellow supervisory LED is illuminated and the supervisory module output is energized. The output should be used to operate a separate AE-30U Module with an audible device. When a break in the circuit occurs the module trouble LED is illuminated and the control panel is placed in system trouble. The supervisory condition is nonlatching, therefore, the supervisory condition will clear if the sprinkler valve is restored to its normal, open position. The Model ZN-34UA is a latching device. Operation is the same as the ZN-34US except that the condition latches and can only be cleared through a system reset after the sprinkler valve is restored to its normal, open position. In addition to gate valves, other sprinkler supervisory limit functions such as water pressure, water level, temperature, air pressure and fire pump supervision may be supervised with the ZN-34US/-UA. All module LEDs are illuminated when the system reset/lamp test switch on the CP-35 main module is operated. The ZN-34US/-UA sprinkler valve supervision module is placement supervised, providing a system trouble signal upon removal from the system. Installation 1. Mount the module to the horizontal mounting brackets in the control enclosure. 2. Install the Model JA-5 (5 in long) bus connector cable assembly between receptacle P2 of the module and receptacle P1 of the module or control panel immediately preceding it in the bus. Note: If the preceding module is on another row in the enclosure, a JA-24 (24 in long) bus connector cable assembly will be required. 3. Modules are to be bus-connected from right to left. For two-row enclosures, the modules in the lower row are to be connected from left to right. Succeeding rows are to be alternately connected, right to left, left to right, etc. 4. If a module is the last module in the system, install either a JS-30 (30 in long) or JS-64 (64 in long) bus connector assembly from the unused receptacle of the last module to terminal 41 of the CP-35 control panel. This completes the module supervision circuit. 5. Wire the circuit(s) as described in the CP-35 Control Panel Instruction Manual (P/N 315085063) Installation and Wiring. Refer to the Wiring illustration. Note: If a zone is not used, the EOL device should be connected to the alarm initiating circuit terminals 2 and 3 (Zone 1) or 4 and 5 (Zone 2) of the module. 6. If a supplementary relay module, annunciator, or other output module is used, then the alarm outputs, terminals 1 (Zone 1) and 6 (Zone 2), should be connected to these units. Wiring Test Refer to the CP-35 Control Panel Instruction Manual, Installation and Wiring. Electrical Information 21.5 VDC at 18mA Supervision and 100mA Supervisory Switch Activated Maximum loop resistance: 100 ohms Siemens Industry, Inc. Building Technologies Division Florham Park, NJ P/N 315-094221-10 Siemens Building Technologies, Ltd. Fire Safety & Security Products 2 Kenview Boulevard Brampton, Ontario L6T 5E4 Canada firealarmresources.com Typical Wiring Diagram ZN-34US ZONE 1 ZONE 2 ZN-34US P1 TO AE-30U STYLE E (SEE NOTE 3) CLASS A SUPERVISION CLASS B SUPERVISION P2 TO AE-30U EOL DEVICE EL-31 USED (SEE NOTE 3) WITH EOL ASSEMBLY 5.6K OHMS, 1/2W, P/N 140-049898 EOL SM-30 OPTIONAL SILENCE SM-30 OPTIONAL SILENCE UNSUPERVISED OUTPUT RATED 24 VDC, 15mA UNFILTERED FULL WAVE RECTIFIED (SEE NOTE 1) SUPERVISORY TROUBLE SUPERVISORY TROUBLE ZONE 1 ZONE 2 UNSUPERVISED OUTPUT RATED 24 VDC, 15mA UNFILTERED FULL WAVE RECTIFIED (SEE NOTE 1) TROUBLE OPERATED SUPERVISORY CONTACT OPERATED (FOR NFPA 72 CENTRAL STATION) TROUBLE OPERATED SUPERVISORY CONTACT OPERATED (FOR NFPA 72 CENTRAL STATION) - + (SEE NOTE 2) SUPERVISED INITIATING CIRCUIT 21.5 VDC at 18mA SUPERVISON and 100mA SUPERVISORY SWITCH ACTIVATED UNFILTERED FULL WAVE RECTIFIED 7 8 9 10 11 12 - + (SEE NOTE 2) * EOL 123 456 SUPERVISED INITIATING CIRCUIT 21.5 VDC at 18mA SUPERVISON and 100mA SUPERVISORY SWITCH ACTIVATED UNFILTERED FULL WAVE RECTIFIED * EOL DEVICE EL-31 USED WITH EOL ASSEMBLY, 5.6K OHMS, 1/2W, P/N 140-049898 NOTES: 1. Normally open parallel connected gate valve contacts, or the equivalent. 2. The maximum loop resistance for each zone is 100 ohms. 3. Connect the supervisory contact operated output of the zone (terminal 6 or 12) to the input of a dedicated AE-30U (terminal 5 or 6). Multiple ZN34US zones may be connected to a single AE-30U. Refer to the CP-35 Wiring Information, P/N 315-085178, for signal factor load units. 4. The ZN-34US is a non-latching device and follows NFPA 72 guidelines for operation. 5. Minimum wire size: Maximum wire size: 18 AWG 12 AWG 6. Positive and negative ground fault impedance threshold 40K ohms. 7. TB positions 1-12 are power limited. Typical Wiring Diagram ZN-34UA ZONE 1 ZN-34UA P1 P2 TO AE-30U (SEE NOTE 3) CLASS A SUPERVISION SM-30 OPTIONAL SILENCE UNSUPERVISED OUTPUT RATED 24 VDC, 15mA UNFILTERED FULL WAVE RECTIFIED (SEE NOTE 1) SUPERVISORY TROUBLE SUPERVISORY TROUBLE ZONE 1 ZONE 2 ZONE 2 CLASS B SUPERVISION TO AE-30U EOL DEVICE EL-31 USED (SEE NOTE 3) WITH EOL ASSEMBLY 5.6K OHMS, 1/2W, P/N 140-049898 EOL SM-30 OPTIONAL SILENCE UNSUPERVISED OUTPUT RATED 24 VDC, 15mA UNFILTERED FULL WAVE RECTIFIED (SEE NOTE 1) TROUBLE OPERATED SUPERVISORY CONTACT OPERATED (FOR NFPA 72 CENTRAL STATION) TROUBLE OPERATED SUPERVISORY CONTACT OPERATED (FOR NFPA 72 CENTRAL STATION) - + (SEE NOTE 2) SUPERVISED INITIATING CIRCUIT 21.5 VDC at 18mA SUPERVISON and 100mA SUPERVISORY SWITCH ACTIVATED UNFILTERED FULL WAVE RECTIFIED 7 8 9 10 11 12 - + (SEE NOTE 2) * EOL 123 456 SUPERVISED INITIATING CIRCUIT 21.5 VDC at 18mA SUPERVISON and 100mA SUPERVISORY SWITCH ACTIVATED UNFILTERED FULL WAVE RECTIFIED * EOL DEVICE EL-31 USED WITH EOL ASSEMBLY, 5.6K OHMS, 1/2W, P/N 140-049898 P/N 315-094221-10 NOTES: 1. Normally open parallel connected gate valve contacts, or the equivalent. 2. The maximum loop resistance for each zone is 100 ohms. 3. Connect the supervisory contact operated output of the zone (terminal 6 or 12) to the input of a dedicated AE-30U (terminal 5 or 6). Multiple ZN34UA zones may be connected to a single AE-30U. Refer to the CP-35 Wiring Information, P/N 315-085178, for signal factor load units. 4. The ZN-34UA is a latching device and follows ULC S527 requirements. 5. Minimum wire size: Maximum wire size: 18 AWG 12 AWG 6. Positive and negative ground fault impedance threshold 40K ohms. 7. TB positions 1-12 are power limited. firealarmresources.com