Temperzone ISK Series Cassette Air Conditioners

Product Review & Specifications

Published: January 2003

Brand: temperzone

Energy Efficient

Product Overview

The temperzone ISK Series Cassette is a split system air conditioner designed for year-round comfort and economy. It is available in both Reverse Cycle (heat pump) and Cooling Only configurations.

Nominal Cooling Capacities: 7.0 kW - 12.3 kW

Applications:

Features and Benefits

General

The ISK Cassette indoor unit, paired with an associated OSA outdoor unit, forms a split system air conditioner suitable for various commercial and public spaces like open office areas, receptions, and showrooms. Its overhead installation saves valuable floor and wall space and avoids the expense of separate ducting, grilles, and diffusers.

Design

The indoor unit is designed for recessed installation within a level ceiling space, centrally located for optimal four-way air distribution. Only the louvred fascia is visible. Its low-profile, elegant design blends harmoniously with room decor. Swing louvre operation prevents stratified air, with options for fixed angles via remote control. Supply air can be ducted to a remote diffuser, and fresh air can be ducted into the unit to mix with room air. The outdoor unit is designed for freestanding or wall mounting.

Comfort

Reverse Cycle systems feature Auto-changeover mode to maintain a preset comfort level by automatically switching between cooling and heating. Manual control of all functions, including one of three fan speeds, is available via a wireless remote control. ?

Economy

The system provides cooling and heating as needed. Reverse cycle models can generate up to 3 kW of heating for every 1 kW of power consumed, offering high efficiency. A programmable start/stop timer adds convenience and economy. Outdoor units are pre-charged with refrigerant, simplifying installation and reducing costs.

Efficiency

The outdoor unit features a high-efficiency scroll compressor and heat exchange coils with inner grooved tubes for improved heat transfer. ?

Quiet Operation

The ISK Cassette emits a quiet whisper of conditioned air due to its carefully designed fan. The compressor is housed in an insulated compartment within the outdoor unit to minimize noise, and the indoor unit is also insulated for noise attenuation. ?

Pre-Heat Cold Draught Protection

The system is designed to prevent cold drafts when switching to heating mode. ?

Ease of Servicing

The air filter is easily accessible for periodic cleaning through a hinged/removable return air panel on the cassette fascia. temperzone provides full technical backup service and readily available spare parts.

Quality Outdoor Cabinet

The outdoor unit is constructed from high-quality galvanised steel with a tough oven-cured polyester powder coating and stainless steel fasteners, built to withstand harsh weather. Outdoor coil fins are epoxy coated for protection in corrosive environments like salt-laden sea air.

Controls and Options

Fingertip Control

An infrared remote control offers versatile and simple operation. Functions include Auto, Heat, Cool, Dry, Fan, and Sleep modes, powered swing louvre, on/off time clock, and manual override. Note: The Heat function is available only on Reverse Cycle systems. ?️

Set & Forget

The ISK system includes a room thermostat. The desired temperature is set via the remote control, and the system manages the rest. In Auto Fan mode, fan speed adjusts based on room and set temperatures.

Optional Equipment

  1. temperzone HP Fan Speed Controller (4 amp): Recommended for cooling in ambient temperatures below 20°C for extended periods.
  2. Wall mounting brackets for outdoor units.

Dual-Zone Alternative

Two independently controlled ISK 73Q indoor units can be connected to a single OSA 146 B twin system outdoor unit, allowing for the servicing of two distinct zones.

ISO 9002 Certification

temperzone operates an ISO 9002 certified quality management system. ✅

Split System Configurations

The ISK Cassette series is available in various configurations: Cooling Only or Reverse Cycle; Single and Three Phase systems.

Standard Split Systems

Indoor UnitOutdoor Unit
ISK 73QOSA 73
ISK 101QOSA 100
ISK 101QOSA 101
ISK 125QOSA 126
ISK 125QOSA 127

Twin Split System

Service two zones with two independent thermostats.

Indoor UnitOutdoor Unit
ISK 73Q (x2)OSA 146 B

Single Phase System

(Refer to specific model configurations above)

Dimensions (mm)

Fig. 1: ISK 73Q - 125Q Cassette Indoor Units

Diagram shows an overhead view and side profile of the indoor cassette unit. Key dimensions are indicated: Ceiling Hole (860-890 mm), Fresh Air Inlet Panel, Remote Supply Air Outlet Panel (785 mm height, 340 mm width, 390 mm depth), Condensate Drain (25 OD), Electrical Conduit Holes, Refrigeration Connections. Overall dimensions are provided in a table.
MODELABCDEF
ISK 73Q290180230165350185
ISK 101Q340230280215380175
ISK 125Q340230280215380175

Note: The manufacturer reserves the right to make changes to specifications at any time without notice or obligation. Certified data is available on request.

Fig. 2: OSA 73 - 146 Outdoor Units

Diagram shows the side and front views of the outdoor unit. Key dimensions and clearance requirements are indicated: 1000 MIN. CLEARANCE, 2000 MIN. CLEARANCE, 100 MIN. CLEARANCE (150 MIN. FOR OSA 126-146), 100 MIN. CLEARANCE (150 MIN. FOR OSA 126 & 127, 1000 MIN. FOR OSA 146). Features include Access Panel, Electrical Conduit Holes (25 DIA.), Drain Hole (15 DIA.), Refrigeration Connections, Mounting Centers (MTG CTR). Overall dimensions are provided in a table.
MODELABCDEF
OSA 73885380655515350185
OSA 100935410695585380175
OSA 101935410695585380175
OSA 126970440800610420180
OSA 127970440800610420180
OSA 1461135480800725430200

Note: OSA 146 has refrig. conn's at each end.

Pipe Length Capacity Loss

On Cooling Cycle Due to Pressure Drop.

Note: Loss percentages are approximations only, due to piping variations. No allowance made for vertical piping.
MODELPIPE SIZE (mm)EQUIVALENT LINE PIPE LENGTH (m)ADDITIONAL PIPE LENGTH TO ALLOW PER BEND
LiquidSuction510152030Suction Pipe Size ODLong 90° Radius
ISK 73Q10162%4%6.5%9%13%16 mm0.30 m
ISK 101Q10162.5%5%8%11%15%19 mm0.43 m
ISK 125Q10191.2%2.5%3.8%5%8%22 mm0.46 m
13191.6%3.2%4.7%
13220.8%1.6%2.4%3.2%4.7%

Specifications

Split System - Reverse Cycle Options

ISK 73Q / OSA 73RISK 101Q / OSA 100RISK 101Q / OSA 101RISK 125Q / OSA 126RISK 125Q / OSA 127RISK 73Q (x2) / OSA 146RB
Cooling Capacity (Total) *2 (kW)7.010.110.112.312.37.0 (x2)
Heating Capacity *3 (kW)7.510.510.513137.5 (x2)
E.E.R. / C.O.P. (Cooling)11.5 / 3.410.5 / 3.110.5 / 3.111.5 / 3.411.5 / 3.411.5 / 3.4
Power Source (volts / phases)230 / 1230 / 1400 / 3230 / 1400 / 3230 / 1
Recom'd Max. Line Length (m)303030303030 (x2)
Max. Height Separation Between Indoor & Outdoor Units (Reverse Cycle Systems) (m)121212121212
Running Amps (Total) / External Fuse (A)9.1 / 2514.5 / 325.7/ph. / 2516 / 326.3/ph. / 259.1 / 30 (x2)

Indoor Units

ISK 73QISK 101QISK 101QISK 125QISK 125QISK 73Q (x2)
Air Flow (l/s) - Low220300300330330220
Air Flow (l/s) - Med255360360385385255
Air Flow (l/s) - High300433433460460300
Sound Pressure dB(A) (SPL) *4 - Low393939414139
Sound Pressure dB(A) (SPL) *4 - Med404545464640
Sound Pressure dB(A) (SPL) *4 - High444848484844
Motor Input (High Speed) (W)9011011015015090 (x2)
Holding Chargedry air
Heat Exchanger Typealuminium slit plate fins to expanded inner grooved copper tube
Indoor Fan Typehigh static mixed flow turbo
Weight (incl. fascia) (kg)374343454537 (x2)

Outdoor Units

OSA 73ROSA 100ROSA 101ROSA 126ROSA 127ROSA 146RB
Sound Pressure (SPL) *5 (dB(A))454949515148
RefrigerantHCFC-22 (R22)
Heat Exchanger Typealuminium corrugated plate fins to expanded inner grooved copper tube
Outdoor Fan Typepropeller
Finishtan polyester powder coat
Weight (kg)7287838789143

Notes:

Materials and specifications subject to change without notice due to the manufacturer's ongoing research and development programme.

Contact Information

Available from:

temperzone limited

Head Office, Auckland: 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email: sales@temperzone.co.nz Website: www.temperzone.biz

temperzone australia pty ltd

Head Office, Sydney: 7A Bessemer St PO Box 6448, Delivery Centre, Blacktown, NSW 2148, AUSTRALIA. Email: sales@temperzone.com.au

Regional Offices:

ISO 9002 CERTIFIED

© temperzone limited 2003

PDF preview unavailable. Download the PDF instead.

ISK Series PR 0203 Acrobat Distiller 5.0.5 for Macintosh

Related Documents

PreviewTemperzone ISD 135K, 160K, 200K, 230K Ducted Split System Installation and Maintenance Guide
This guide provides installation and maintenance instructions for Temperzone ISD Ducted Split System R410A Indoor Units, including models ISD 135K, 160K, 200K, and 230K. It covers unit dimensions, mounting options, condensate drain, electrical wiring, and application considerations for optimal performance and noise reduction.
PreviewTemperzone Econex Ducted Split Units: High Efficiency Air Conditioning
Explore Temperzone's Econex range of air-cooled ducted split air conditioning units, featuring R32 refrigerant for lower GWP, advanced inverter technology, and high performance for commercial and industrial applications. Discover features, specifications, and control options.
PreviewTemperzone ISD 230K / OSA 230RKTH Ducted Split System Air Conditioner Technical Data
Technical data and specifications for the Temperzone ISD 230K / OSA 230RKTH Ducted Split System Air Conditioner, including performance data, dimensions, and safety features.
PreviewTemperzone ISD 324KYX OSA 324RKTFV Air Conditioner Specifications and Dimensions
Comprehensive technical specifications, dimensional data, and wiring schematics for the Temperzone ISD 324KYX Indoor Unit and OSA 324RKTFV Outdoor Unit air conditioning system. Features include cooling/heating capacity, electrical inputs, refrigerant details, and installation guidance.
PreviewTemperzone ISD 211LYX and OSA 211RLTFH Air Conditioner Specifications and Wiring
Detailed technical specifications, dimensions, and wiring diagrams for the Temperzone ISD 211LYX indoor unit and OSA 211RLTFH outdoor unit. Includes performance data, accessories, optional controls, and electrical connection schematics.
PreviewTemperzone OSA 670RKTBQ R410A Split System Outdoor Unit Installation and Maintenance Guide
Comprehensive installation and maintenance guide for the Temperzone OSA 670RKTBQ Reverse Cycle R410A Split System Outdoor Unit, including general information, installation procedures, piping, electrical requirements, system checks, startup procedures, and maintenance schedules.
PreviewTemperzone and Hitachi Air Conditioning Warranty New Zealand
Comprehensive guide to the Temperzone and Hitachi air conditioning product warranty in New Zealand, detailing terms, conditions, coverage, exclusions, claim procedures, and recommended maintenance.
PreviewTemperzone TZT-701 Thermostat Kit Installation Instructions for ISD/OSA-RK & OPA-RK Series
Comprehensive installation guide for the Temperzone TZT-701 Thermostat Kit, designed for ISD/OSA-RK and OPA-RK Series air conditioning units with digital systems. Includes components, installation steps, and commissioning.