REPORT No.SZ25020263W03
TEST REPORT

APPLICANT

: Linkplay Technology Inc.

PRODUCT NAME : WiiM Amp Ultra

MODEL NAME

: AMP003

BRAND NAME

: WiiM

FCC ID

: 2BABF-AMP003

STANDARD(S)

: 47 CFR Part 15 Subpart C

RECEIPT DATE

: 2025-03-19

TEST DATE

: 2025-04-15 to 2025-05-09

ISSUE DATE

: 2025-05-19

Edited by:

Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 1 of 38

REPORT No.SZ25020263W03
DIRECTORY
1. Summary of Test Result 3 1.1. Testing Applied Standards 4 1.2. Test Equipment List 5 1.3. Measurement Uncertainty 7 1.4. Testing Laboratory7 2. General Description 8 2.1. Information of Applicant and Manufacturer 8 2.2. Information of EUT8 2.3. Channel List of EUT 9 2.4. Test Configuration of EUT 10 2.5. Test Conditions  11 2.6. Test Setup Layout Diagram  12 3. Test Results  15 3.1. Conducted Emission  15 3.2. Restricted Frequency Bands  16 3.3. Radiated Emission  17 Annex A Test Data and Result  19

Version 1.0

Change History Date 2025-05-19

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 2 of 38

1. Summary of Test Result

REPORT No.SZ25020263W03

No. Section Description

Test Date

Test Engineer

Result

Method Determination
/Remark

1 15.203

Antenna Requirement

N/A

N/A

N/ANote1

N/A

2 N/A

Duty Cycle of Test Signal

N/A

N/A

N/ANote1

N/A

Maximum Peak

3 15.247(b) Conducted

N/A

Output Power

N/A

N/ANote1

N/A

Maximum

4

15.247(b)

Average Conducted

N/A

N/A

N/ANote1

N/A

Output Power

5 15.247(a) Bandwidth

N/A

N/A

N/ANote1

N/A

Conducted

6

15.247(d)

Spurious Emission and

N/A

N/A

N/ANote1

N/A

Band Edge

7

15.247(e)

Power Spectral Density

N/A

N/A

N/ANote1

N/A

8 15.207

Conducted Emission

May 09, 2025

Fan Shengquan

PASS

No deviation

Restricted

9 15.247(d) Frequency

Apr. 09, 2025 Gao Jianrou PASS No deviation

Bands

10

15.209, 15.247(d)

Radiated Emission

Apr. 22, 2025 Gao Jianrou PASS No deviation

Note 1: The test results of all conducted test items please refer to the module FCC test report

(Report No.: SZ24040154W03), which issued on Jul. 26, 2024.

Note 2: The tests were performed according to the method of measurements prescribed in ANSI

C63.10-2013 and KDB 558074 D01 v05r02.

Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method

determination" column of add, deviate or exclude from the specific method shall be explained in the

"Remark" of the above table.

Note 4: When the test result is a critical value, we will use the measurement uncertainty give the

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 3 of 38

REPORT No.SZ25020263W03
judgment result based on the 95% confidence intervals.
1.1. Testing Applied Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:  47 CFR Part 15 Subpart C Radio Frequency Devices

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 4 of 38

1.2. Test Equipment List

REPORT No.SZ25020263W03

1.2.1 Conducted Emission Test Equipment

Equipment

Serial No.

Type

Receiver

MY56400093 N9038A

LISN

8127449

NSLK 8127

Pulse Limiter

VTSD 9561

VTSD

(10dB)

F-B #206

9561-F

RF Coaxial Cable (DC-100MHz)

BNC

MRE04

Manufacturer KEYSIGHT
Schwarzbeck

Cal. Date Due Date 2025.01.06 2026.01.05
2025.01.09 2026.01.08

Schwarzbeck 2024.05.30 2025.05.29

Qualwave

2024.07.02 2025.07.01

1.2.2 List of Software Used Description JS32-RE
TS+ -[JS32-CE]

Manufacturer Tonscend Tonscend

Software Version 5.0.0 2.5.0.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 5 of 38

REPORT No.SZ25020263W03

1.2.3 Radiated Test Equipment

Equipment

Serial No.

Signal Analyzer MY56060145

Test Antenna - BiLog

9163-519

Test Antenna Loop

1519-022

Test Antenna ­ Horn

01774

Test Antenna ­ BBHA9170

Horn

#773

Preamplifier (10MHz-6GHz)

46732

Preamplifier (2GHz-18GHz)

61171/61172

Preamplifier (18GHz-40GHz)

DS77209

Type N9020A VULB 9163
FMZB1519
BBHA 9120D
BBHA9170 S10M100L38
02 S020180L32
03 DCLNA0118-
40C-S

RF Coaxial Cable (DC-18GHz)

MRE001

PE330

RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-18GHz)
Notch Filter
Anechoic Chamber Anechoic Chamber

MRE002 MRE003 22290045 22290046 22120181
N/A N/A N/A

CLU18
CLU18
QA360-40KK-0.5
QA360-40KKF-2
QA500-18NN-5
WRCG-24002483.5-60SS
9m*6m*6m
9m*6m*6m

Manufacturer Agilent
Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP.
Decentest
Pasternack
Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright
CRT CRT

Cal. Date 2024.05.30 2024.06.22 2024.06.03 2024.06.22 2024.06.22 2024.05.30 2024.05.30 2024.05.30
2024.05.30
2024.05.30 2024.05.30 2024.07.03 2024.07.03 2024.07.03
N/A 2025.04.19 2022.11.30

Due Date 2025.05.29 2025.06.21 2025.06.02 2025.06.21 2025.06.21 2025.05.29 2025.05.29 2025.05.29
2025.05.29
2025.05.29 2025.05.29 2025.07.02 2025.07.02 2025.07.02
N/A 2028.04.18 2025.11.29

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 6 of 38

1.3. Measurement Uncertainty

REPORT No.SZ25020263W03

Test Items Restricted Frequency Bands Radiated Emission Conducted Emission
1.4. Testing Laboratory

Uncertainty ±5% ±2.95dB ±2.44dB

Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95%

Laboratory Name
Laboratory Address
Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192
226174

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 7 of 38

2. General Description

REPORT No.SZ25020263W03

2.1. Information of Applicant and Manufacturer

Applicant Applicant Address Manufacturer Manufacturer Address

Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560

2.2. Information of EUT

Product Name:

WiiM Amp Ultra

Sample No.:

4#, 25#

Hardware Version:

A98D V02+Main Board V02

Software Version:

Linkplay.5.2.708867

Modulation Technology:

DSSS, OFDM, OFDMA

Modulation Type:

Refer to section2.3

Wireless Technology:

802.11b, 802.11g, 802.11n (HT20), 802.11ax (HEW20)

Operating Frequency Range: 2412MHz­2462MHz

Antenna Type:

PIFA Antenna

Antenna Gain:

ANT1: 3.46dBi; ANT2: 3.46dBi

Note 1: The test results of all conducted test items please refer to the module FCC test report

(Report No.: SZ24040154W03), which issued on Jul. 26, 2024. We only recorded the radiated test

result in this report.

Note 2: The EUT has two antennas and it operates in single antenna. Both of the two antennas

were evaluated separately, only the worst test result (ANT1) were recorded in the test report.

Note 3: For a more detailed description, please refer to Specification or User's Manual supplied by

the applicant and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 8 of 38

2.3. Channel List of EUT

REPORT No.SZ25020263W03

Nominal Channel Bandwidth

Channel

Frequency (MHz)

1

2412

2

2417

3

2422

20MHz

4

2427

5

2432

6

2437

7

2442

Note 1: The black bold channels were selected for test.

Channel
8 9 10 11

Frequency (MHz)
2447 2452 2457 2462

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 9 of 38

2.4. Test Configuration of EUT

REPORT No.SZ25020263W03

2.4.1.Modulation Type and Data Rate of EUT

Mode

Bandwidth (MHz)

Modulation Modulation

Technology

Type

Data Rate

RU Size

DBPSK

802.11b

20

DSSS

DQPSK

1/2/5.5/11Mbps

N/A

CCK

BPSK

802.11g

20

OFDM

QPSK 16QAM

6/9/12/18/24/36/48/54 Mbps

N/A

64QAM

BPSK

802.11n

20 (HT20/40)

OFDM

QPSK 16QAM

MCS0~MCS7

N/A

64QAM

BPSK

QPSK

802.11ax

20 (HEW20)

OFDM/ OFDMA

16QAM 64QAM

MSC0~MCS11

26/52/106

256QAM

1024QAM

Note1: The worst-case mode (bold face) in all data rates has been determined during the pre-scan,

only the test data of the worst-case were recorded in this report.

Note2: The RF signal transmission of EUT is controlled by the build-in engineering mode which is

provided by the manufacturer. The recorded power setting value is the maximum that the

engineering mode has configuration during testing.

2.4.2.802.11ax RU Allocation

BW (MHz)
20

Full (Tone)
242

RU Size Partial
(Tone) BW (MHz)

User

RU Offset

26

2

9 @0/1/2/3/4/5/6/7/8

52

4

4 @37/38/39/40

106

8

2 @53/54

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 10 of 38

2.5. Test Conditions
Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa)

15­35 30­60 86­106

REPORT No.SZ25020263W03

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 11 of 38

2.6. Test Setup Layout Diagram
2.6.1.Conducted Emission Measurement

REPORT No.SZ25020263W03

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 12 of 38

2.6.2.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz

REPORT No.SZ25020263W03

2) For radiated emissions from 30MHz to1GHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 13 of 38

3) For radiated emissions above 1GHz

REPORT No.SZ25020263W03

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 14 of 38

3. Test Results

REPORT No.SZ25020263W03

3.1. Conducted Emission

3.1.1.Requirement

According to FCC section 15.207, for an intentional radiator that is designed to be connected to the

public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power

line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following

table, as measured using a 50µH/50 line impedance stabilization network (LISN).

Frequency Range (MHz)

Conducted Limit (dBµV)

Quai-peak

Average

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

Note:

(a) The lower limit shall apply at the band edges.

(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

3.1.2.Test Procedures

The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013.

3.1.3.Test Setup Layout Refer to chapter 2.6.2 in this report.

3.1.4.Test Result Refer to Annex A.1 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 15 of 38

3.2. Restricted Frequency Bands

REPORT No.SZ25020263W03

3.2.1.Requirement
According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a).

3.2.2.Test Procedures
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f  1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize

3.2.3.Test Setup Layout Refer to chapter 2.6.3 in this report.

3.2.4.Test Result Refer to Annex A.2 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 16 of 38

3.3. Radiated Emission

REPORT No.SZ25020263W03

3.3.1.Requirement

According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a).

According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions

from an intentional radiator shall not exceed the field strength levels specified in the following

table:

Frequency (MHz)

Field Strength (µV/m)

Measurement Distance (m)

0.009 - 0.490

2400/F(kHz)

300

0.490 - 1.705

24000/F(kHz)

30

1.705 - 30.0

30

30

30 - 88

100

3

88 - 216

150

3

216 - 960

200

3

Above 960

500

3

Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement

instrumentation employing an average detector, measurement using instrumentation with a peak

detector function, corresponding to 20dB above the maximum permitted average limit.

Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and

74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined

in Section 15.205(a), also should comply with the radiated emission limits specified in Section

15.209(a)(above table).

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 17 of 38

REPORT No.SZ25020263W03
3.3.2.Test Procedures
The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode.
For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector.
For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements.
The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response.
3.3.3.Test Setup Layout
Refer to chapter 2.6.3 in this report.
3.3.4.Test Result
Refer to Annex A.3 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 18 of 38

REPORT No.SZ25020263W03
Annex A Test Data and Result
A.1. Conducted Emission
The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be remeasured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+TV+HDMl cable+Load+Fiber box+Mobile phone+Audio+U disk+WIFI TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 19 of 38

B. Test Plot:

REPORT No.SZ25020263W03

(L Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1500

53.33

37.26

2 0.1680

52.97

33.56

3 0.2760

51.76

38.90

4 0.3570

51.74

36.96

5 0.3930

52.11

34.81

6 0.4155

48.78

36.04

Limit (dBµV)

Quai-peak 66.00 65.06 60.93 58.80 58.00 57.54

Average 56.00 55.06 50.93 48.80 48.00 47.54

Power-line Verdict

PASS

PASS

Line

PASS PASS

PASS

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 20 of 38

REPORT No.SZ25020263W03

(N Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1635

54.66

33.67

2 0.2085

57.82

43.47

3 0.2850

52.51

36.78

4 0.3525

52.50

37.94

5 0.4065

48.61

33.65

6 0.6360

41.19

27.49

Limit (dBµV)

Quai-peak 65.28 63.26 60.67 58.90 57.72 56.00

Average 55.28 53.26 50.67 48.90 47.72 46.00

Power-line Verdict

Neutral

PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 21 of 38

REPORT No.SZ25020263W03
A.2. Restricted Frequency Bands
Note 1: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (Vertical) was recorded in this test report. Note 2 All test modes and bandwidth were considered and evaluated respectively by performing full test, only the worst data were recorded for each bandwidth.
802.11b Mode Plot for Channel 1

Fre. (MHz) 2376.31 2379.67 2382.91 2383.63 2386.28 2386.28

Reading [dBV]
16.1 7.1 18.1 9.9 19.8 11.6

Level [dBV/m]
48.59 39.63 50.63 42.42 52.35 44.08

Factor [dB/m] 32.490 32.510 32.520 32.520 32.530 32.530

Limit [dBV/m]
74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 25.41 14.37 23.37 11.58 21.65 9.92

Height [cm] 150 150 150 150 150 150

Angle [°] 226 226 226 226 226 226

Detector
PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 22 of 38

Plot for Channel 11

REPORT No.SZ25020263W03

Fre. (MHz) 2484.52 2487.29 2487.32 2490.50 2490.52 2494.45

Reading [dBV]
20.0 10.4 21.6 20.7 10.2 9.4

Level [dBV/m]
53.04 43.43 54.61 53.72 43.23 42.38

Factor [dB/m] 33.030 33.030 33.030 33.020 33.020 33.010

Limit [dBV/m]
74.00 54.00 74.00 74.00 54.00 54.00

Margin [dB] 20.96 10.57 19.39 20.28 10.77 11.62

Height [cm] 150 150 150 150 150 150

Angle [°] 227 227 227 227 227 227

Detector
PK AV PK PK AV AV

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 23 of 38

802.11ax (HEW20) RU26 Mode Plot for Channel 1

REPORT No.SZ25020263W03

Fre. (MHz) 2364.65 2379.55 2381.47 2383.03 2384.95 2389.88

Reading [dBV]
6.3 9.2 35.4 35.7 12.0 37.3

Level [dBV/m]
38.76 41.71 67.89 68.26 44.56 69.87

Factor [dB/m] 32.450 32.510 32.510 32.520 32.530 32.540

Limit [dBV/m]
54.00 54.00 74.00 74.00 54.00 74.00

Margin [dB] 15.24 12.29 6.11 5.74 9.44 4.13

Height [cm] 150 150 150 150 150 150

Angle [°] 225 225 293 274 225 233

Detector
AV AV PK PK AV PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 24 of 38

Plot for Channel 11

REPORT No.SZ25020263W03

Fre. (MHz) 2483.57 2483.62 2484.59 2486.27 2487.82 2490.72

Reading [dBV]
36.2 11.5 37.1 11.2 11.4 32.9

Level [dBV/m]
69.18 44.54 70.13 44.23 44.37 65.95

Factor [dB/m] 33.030 33.030 33.030 33.030 33.020 33.020

Limit [dBV/m]
74.00 54.00 74.00 54.00 54.00 74.00

Margin [dB] 4.82 9.46 3.87 9.77 9.63 8.05

Height [cm] 150 150 150 150 150 150

Angle [°] 218 227 218 218 227 218

Detector
PK AV PK AV AV PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 25 of 38

REPORT No.SZ25020263W03
A.3. Radiated Emission
According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average).
The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note 2: All test modes and bandwidth were considered and evaluated respectively by performing full test, only the worst data were recorded for each bandwidth. Note 3: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note 4: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 26 of 38

802.11b Mode Plot for Channel 1

REPORT No.SZ25020263W03

Fre. (MHz) 56.00 104.74 163.92 200.00 531.27 750.02

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
61.7 67.4 68.4 65.7 53.0 42.4

Level [dBV/m]
33.63 38.13 37.32 36.91 34.08 27.51

Factor [dB/m] -28.050 -29.300 -31.050 -28.780 -18.940 -14.840

Limit [dBV/m]
40.00 43.50 43.50 43.50 46.00 46.00

Margin [dB] 6.37 5.37 6.18 6.59 11.92 18.49

Height [cm] 150 150 150 150 150 150

Angle [°] 9 340 176 78 190 206

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 27 of 38

REPORT No.SZ25020263W03

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1064.81 1065.21 2410.68 2411.48 3771.02 3794.59 6740.25 6779.25 11086.52 11113.95 14693.48 14705.05

Reading [dBV]
49.4 37.7 52.3 48.4 40.8 50.1 44.5 35.1 30.7 39.1 35.8 26.7

Level [dBV/m]
46.82 35.05 57.72 53.80 32.46 41.90 48.56 38.95 44.59 53.08 56.35 47.26

Factor [dB/m] -2.620 -2.620 5.380 5.390 -8.350 -8.180 4.100 3.890 13.900 14.000 20.590 20.550

Limit [dBV/m]
74.00 54.00
54.00 74.00 74.00 54.00 54.00 74.00 74.00 54.00

Margin [dB] 27.18 18.95 21.54 32.10 25.44 15.05 9.41 20.92 17.65 6.74

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 49 49 314 319 186 12 186 311 25 40 271 79

Detector
PK AV PK AV AV PK PK AV AV PK PK AV

Verdict
PASS PASS
NA NA PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 28 of 38

REPORT No.SZ25020263W03

Fre. (MHz) 30.63 52.55 101.88 184.33 282.65 533.26

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
65.4 62.9 63.7 63.1 60.4 52.7

Level [dBV/m]
34.60 34.99 34.08 33.01 34.11 33.69

Factor [dB/m] -30.750 -27.860 -29.600 -30.090 -26.310 -19.030

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 5.40 5.01 9.42 10.49 11.89 12.31

Height [cm] 150 150 150 150 150 150

Angle [°] 317 310 131 239 273 246

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 29 of 38

REPORT No.SZ25020263W03

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1063.61 1064.41 2410.68 2411.48 3189.86 3189.86 4136.18 4137.03 11102.80 11106.23 14672.90 14676.33

Reading [dBV]
35.2 46.4 53.6 49.7 52.8 45.5 51.8 40.9 39.5 30.2 36.0 26.8

Level [dBV/m]
32.57 43.80 58.96 55.05 42.05 34.76 43.70 32.89 53.58 44.23 56.57 47.31

Factor [dB/m] -2.640 -2.620 5.380 5.390 -10.760 -10.760 -8.060 -8.050 14.070 14.040 20.530 20.540

Limit [dBV/m]
54.00 74.00
74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 21.43 30.20 31.95 19.24 30.30 21.11 20.42 9.77 17.43 6.69

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 88 66 232 237 150 150 110 110 3 69 95 202

Detector
AV PK PK AV PK AV PK AV PK AV PK AV

Verdict
PASS PASS
NA NA PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 30 of 38

Plot for Channel 6

REPORT No.SZ25020263W03

Fre. (MHz) 55.90 104.79 163.96 264.56 331.78 651.27

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
62.2 66.9 66.7 61.9 58.9 46.2

Level [dBV/m]
34.15 37.62 35.63 34.43 34.50 29.46

Factor [dB/m] -28.020 -29.270 -31.040 -27.480 -24.390 -16.720

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 5.85 5.88 7.87 11.57 11.50 16.54

Height [cm] 150 150 150 150 150 150

Angle [°] 3 309 189 168 175 296

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 31 of 38

REPORT No.SZ25020263W03

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1064.01 1065.61 2433.49 2434.29 3187.72 3198.01 7048.83 7188.98 10666.93 10678.08 14535.33 14618.90

Reading [dBV]
35.3 50.6 47.3 42.7 53.4 44.6 44.8 35.0 41.4 31.0 36.2 26.8

Level [dBV/m]
32.65 47.94 53.03 48.48 42.63 33.80 49.14 39.97 53.74 43.39 56.23 47.14

Factor [dB/m] -2.620 -2.620 5.720 5.740 -10.740 -10.830 4.340 5.000 12.340 12.380 19.990 20.380

Limit [dBV/m]
54.00 74.00
74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 21.35 26.06 31.37 20.20 24.86 14.03 20.26 10.61 17.77 6.86

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 54 54 328 322 324 324 283 190 110 0 69 296

Detector
AV PK PK AV PK AV PK AV PK AV PK AV

Verdict
PASS PASS
NA NA PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 32 of 38

REPORT No.SZ25020263W03

Fre. (MHz) 30.63 62.50 90.43 163.96 532.82 946.16

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
66.4 64.7 64.9 63.9 49.2 39.4

Level [dBV/m]
35.65 35.96 33.38 32.86 30.20 28.34

Factor [dB/m] -30.750 -28.780 -31.480 -31.040 -19.010 -11.070

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 4.35 4.04 10.12 10.64 15.80 17.66

Height [cm] 150 150 150 150 150 150

Angle [°] 265 133 182 54 351 245

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 33 of 38

REPORT No.SZ25020263W03

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1062.81 1066.01 2433.49 2434.29 3648.45 4874.62 7537.42 7594.42 11186.38 11593.96 14541.76 14600.05

Reading [dBV]
34.5 47.9 47.1 42.7 50.5 41.5 44.0 34.5 30.6 40.2 36.7 26.7

Level [dBV/m]
31.83 45.27 52.80 48.45 41.74 36.52 48.52 39.40 44.11 54.70 56.73 47.05

Factor [dB/m] -2.640 -2.620 5.720 5.740 -8.800 -4.970 4.560 4.900 13.560 14.480 20.030 20.340

Limit [dBV/m]
54.00 74.00
74.00 54.00 74.00 54.00 54.00 74.00 74.00 54.00

Margin [dB] 22.17 28.73 32.26 17.48 25.48 14.60 9.89 19.30 17.27 6.95

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 64 69 174 174 124 70 31 138 96 83 259 4

Detector
AV PK PK AV PK AV PK AV AV PK PK AV

Verdict
PASS PASS
NA NA PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 34 of 38

Plot for Channel 11

REPORT No.SZ25020263W03

Fre. (MHz) 56.05 104.74 163.96 264.51 531.08 749.92

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
62.2 66.9 66.9 62.8 51.8 45.6

Level [dBV/m]
34.12 37.60 35.82 35.26 32.90 30.72

Factor [dB/m] -28.050 -29.300 -31.040 -27.490 -18.930 -14.840

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 5.88 5.90 7.68 10.74 13.10 15.28

Height [cm] 150 150 150 150 150 150

Angle [°] 359 296 178 9 157 157

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 35 of 38

REPORT No.SZ25020263W03

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1067.61 1068.01 2461.09 2461.49 3187.29 3187.72 7195.41 7225.84 11112.23 11128.09 14549.47 14713.62

Reading [dBV]
33.8 47.5 49.5 44.8 51.8 42.6 44.3 35.2 30.5 40.4 27.4 36.2

Level [dBV/m]
31.19 44.90 55.43 50.69 41.08 31.85 49.37 39.88 44.53 54.29 47.48 56.64

Factor [dB/m] -2.600 -2.600 5.950 5.940 -10.730 -10.740 5.070 4.730 14.010 13.910 20.070 20.480

Limit [dBV/m]
54.00 74.00
74.00 54.00 74.00 54.00 54.00 74.00 54.00 74.00

Margin [dB] 22.81 29.10 32.92 22.15 24.63 14.12 9.47 19.71 6.52 17.36

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 69 69 326 326 43 43 271 110 30 83 16 43

Detector
AV PK PK AV PK AV PK AV AV PK AV PK

Verdict
PASS PASS
NA NA PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 36 of 38

REPORT No.SZ25020263W03

Fre. (MHz) 30.58 52.60 104.74 282.65 503.82 934.91

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
65.4 63.4 62.7 61.0 50.4 40.6

Level [dBV/m]
34.64 35.54 33.38 34.71 29.92 28.82

Factor [dB/m] -30.750 -27.850 -29.300 -26.310 -20.470 -11.760

Limit [dBV/m]
40.00 40.00 43.50 46.00 46.00 46.00

Margin [dB] 5.36 4.46 10.12 11.29 16.08 17.18

Height [cm] 150 150 150 150 150 150

Angle [°] 340 261 129 275 157 129

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 37 of 38

REPORT No.SZ25020263W03

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1063.61 1066.01 2461.49 2461.89 3198.43 3198.86 4923.91 4924.34 11092.95 11114.80 14725.62 14760.76

Reading [dBV]
36.8 48.1 46.7 51.0 53.1 44.9 48.2 40.8 40.8 30.2 35.6 27.4

Level [dBV/m]
34.17 45.49 52.66 56.96 42.31 34.01 43.22 35.77 54.75 44.20 55.94 47.45

Factor [dB/m] -2.640 -2.620 5.940 5.940 -10.830 -10.840 -4.980 -4.980 13.990 14.000 20.380 20.070

Limit [dBV/m]
54.00 74.00
74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin [dB] 19.83 28.51 31.69 19.99 30.78 18.23 19.25 9.80 18.06 6.55

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 76 81 152 152 21 35 126 126 60 351 139 35

Detector
AV PK AV PK PK AV PK AV PK AV PK AV

Verdict
PASS PASS
NA NA PASS PASS PASS PASS PASS PASS PASS PASS