1. Packing List

  • 1 x VS133 Device
  • 4 x Ceiling Mounting Kits
  • 1 x Multi-Interface (PoE Version Only)
  • 1 x Quick Start Guide
  • 8 x Staff Tags
  • 1 x Warranty Card
  • 1 x Power Adapter (LoRaWAN® Version Only)

2. Hardware Introduction

PoE Version

→ RGB LED Indicator

→ Reset Button

→ ToF Sensor

→ Ethernet Interface (PoE)

LoRaWAN® Version

→ RGB LED Indicator

→ Reset Button/Wi-Fi Button

→ ToF Sensor

→ DC Interface

3. Button Patterns

FunctionActionLED Indicator
Turn ON/OFF Wi-Fi (LoRaWAN® Version Only)Press and hold the button for more than 3 seconds.Enable/Disable: Blue light blinks for 3 seconds
Wi-Fi ON: Blue light blinks constantly
Wi-Fi OFF: Green light blinks constantly
Reset to Factory DefaultPress and hold the button for more than 10 seconds.Green light blinks until the reset process is completed

4. Power Supply

PoE Version
VS133-P is powered by 802.3at standard PoE. Choose one of the following methods to power up the device:

  • Powered by PoE Switch
  • Powered by PoE Injector

LoRaWAN® Version
VS133-868M/915M/470M is powered by adapter (12VDC, 2A).

Diagrams showing connections via PoE Switch/Injector and via Power Adapter are described textually.

5. Installation

Installation Steps:

  1. Ensure the ceiling thickness is more than 30mm. Attach the mounting sticker, drill 4 holes (6mm diameter). Drill a wire hole if wires need to extend inside the ceiling.
  2. Fix the wall plugs into the ceiling holes.
  3. Remove the device cover. Connect required wires and pass them through the device's wire hole. Alternatively, break the side block if wires need to protrude from the side. (Note: If using the Alarm I/O port of VS133-P, connect the Multi-interface to the device).
  4. Fix the device to the wall plugs using mounting screws.
  5. Replace the device cover.

Recommended Height & Detection Area:

The maximum installation height is 3.5m. Monitored areas for people counting at different heights:

Installation Height (m)Monitored Area (m)Detection Area (m)
2.55.75 x 4.201.84 x 1.34
2.65.98 x 4.362.07 x 1.51
2.76.21 x 4.532.30 x 1.68
2.86.44 x 4.702.53 x 1.85
2.96.67 x 4.872.76 x 2.01
3.06.90 x 5.032.99 x 2.18
3.17.13 x 5.203.22 x 2.35
3.27.36 x 5.373.45 x 2.52
3.37.59 x 5.543.68 x 2.69
3.47.82 x 5.713.91 x 2.85
3.58.05 x 5.874.14 x 3.02

Installation Notes:

  • Ensure the detection part of the sensor faces straight down and is in line with the ceiling.
  • Avoid direct Infrared LED light in the detection area.
  • Do not install the sensor close to glass or mirrors.
  • Ensure no other objects block the ToF light within a 30cm radius of the device's front.
  • Though the device is compliant with Class 1 (IEC/EN 60825-1:2014), please DO NOT look at the ToF sensor too closely and directly.

6. Access from Web Browser

The VS133 provides a user-friendly web GUI for configuration, accessible via Wi-Fi or Ethernet. A password must be set on first use.

Default Settings:

  • Wi-Fi SSID: People Counter_xxxxxx (found on the label)
  • Wi-Fi IP: 192.168.1.1 (LoRaWAN® Version)
  • ETH IP: 192.168.5.220 (PoE Version)

Access Methods:

Wireless Method: Enable wireless network connection on your computer, search for the corresponding Wi-Fi SSID, connect to it, then type 192.168.1.1 in your browser to access the web GUI.

Wired Method: Connect the device to your computer via Ethernet. Manually assign your computer's IP address to 192.168.5.xxx (e.g., 192.168.5.100). Then, type 192.168.5.220 in your browser to access the web GUI.

The TCP/IPv4 Properties dialog for manual IP configuration is described as follows: Set 'Obtain an IP address automatically' to 'Use the following IP address'. Enter '192.168.5.100' for IP address and '255.255.255.0' for Subnet mask. Leave Default gateway blank or set as needed. Set 'Obtain DNS server address automatically' to 'Use the following DNS server addresses' if required.

7. FCC Statement

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

All software & files can be downloaded from https://www.milesight-iot.com/documents-download/

Milesight IoT Co., Ltd. | www.milesight.com

Building C09, Software Park Phase III, Xiamen 361024, Fujian, China

Models: VS133, VS133 AI ToF People Counting Sensor, AI ToF People Counting Sensor, ToF People Counting Sensor, People Counting Sensor, Counting Sensor, Sensor

File Info : application/pdf, 2 Pages, 965.26KB

PDF preview unavailable. Download the PDF instead.

Milesight-AI-ToF-People-Counting-Sensor-1

References

Acrobat Distiller 11.0 (Windows)

Related Documents

PreviewMilesight VS133 AI ToF People Counting Sensor User Guide
Comprehensive user guide for the Milesight VS133 AI ToF People Counting Sensor, detailing its features, hardware, installation, configuration, communication protocols (LoRaWAN, PoE), and operation for accurate people counting in various environments. Includes safety precautions and technical specifications.
PreviewMilesight VS133 AI ToF People Counting Sensor User Guide
Comprehensive user guide for the Milesight VS133 AI ToF People Counting Sensor, detailing its features, hardware, operation, installation, communication protocols, and troubleshooting. Learn how to deploy and configure this advanced sensor for accurate people counting in various environments.
PreviewMilesight VS133 AI ToF People Counting Sensor User Guide
Comprehensive user guide for the Milesight VS133 AI ToF People Counting Sensor, detailing its features, hardware, operation, installation, communication protocols, and system settings.
PreviewMilesight VA31 Staff Lanyard Datasheet
Datasheet for the Milesight VA31 Staff Lanyard, designed for staff recognition by people counting sensors, offering anonymity and accuracy. Details specifications, usage requirements, and wear guide.
PreviewMilesight People Sensing Product Portfolio: Enhance Efficiency and Insight
Explore the Milesight People Sensing Product Portfolio, featuring advanced AI-driven sensors for occupancy, people counting, and human behavior analysis. Discover solutions for smart buildings, retail, transportation, and elderly care, optimizing space, improving security, and driving operational efficiency.
PreviewMilesight People Counter Accessories: Mounting Kits & Staff Exclusion
Discover Milesight's comprehensive range of accessories for People Counters, including versatile mounting brackets, flush mount covers, and staff exclusion badges and lanyards for VS125 and VS13X series devices.
PreviewMilesight VS132 3D ToF People Counting Sensor User Guide
Comprehensive user guide for the Milesight VS132 3D Time-of-Flight (ToF) People Counting Sensor, featuring LoRaWAN connectivity. Covers installation, configuration, operation, and technical specifications.
PreviewMilesight Product Catalog: AI, IoT, 5G, and LoRaWAN Sensing Solutions
Explore the comprehensive Milesight product catalog featuring AI-powered surveillance cameras, IoT sensors, 5G connectivity solutions, and LoRaWAN devices for smart buildings, security, and environmental monitoring.