GV-OS-Security

GigaVUE Security Hardening

This guide provides the best practices on securing the GigaVUE operating system.

Topics:

Introduction

This guide provides you information on the options that are available in the GigaVUE-OS to harden a device against attack by threat actors and other threat vectors, such as brute force attacks.

This document is intended for an audience who is familiar with the configuration of GigaVUE-OS Appliances.

Physical Control

Physical access to any device can result in equipment that has been tampered with, both in transit and also after it is deployed. Before deploying, you must ensure that the device must be stored in safe location and also verify that the device is not tampered with before installation.

Checking for tampering

When shipped from the factory, all GigaVUE appliances are provided in a sealed box. You must inspect the box before installation to ensure that it has not been opened.

Anti-tampering stickers

Tampering of the GigaVUE Appliance can be detected using Anti-Tampering Stickers which Gigamon provides for purchase. These ensure that any physical intrusion into the chassis of the device can be easily detected. Instructions for best placement of the Anti-Tampering stickers is provided. Incorrect placement of sticker might result in closing of ventilation holes which can adversely affect the air flow required for cooling the appliance.

Disabling the Serial Interface

GigaVUE Appliance must be installed in a physically secure environment. It is recommended to disable the serial interface. The login to GigaVUE-OS using serial port is secured by authentication methods (i.e. local / TACACS+ / RADIUS).

By default, the serial port session does not log out when a serial port is disconnected. You must configure the session time.

NOTE: Access to the serial port is required to reset the device. If you lose the login credentials for the GigaVUE-OS appliance, you will not be able to factory-reset the device. It requires a RMA which will have associated costs.

To disable the Serial Interface, run the command no serial enable.

gigavue-appliance > enable
gigavue-appliance # configure terminal
gigavue-appliance (config) # no serial enable
Disable serial console will make serial connection unusable.
Only use this config command when you have available telnet/ssh connections.
Enter 'YES' to confirm this operation: YES
Serial Console disabled.
gigavue-appliance (config) #

You can enable the serial interface by running the command serial enable

gigavue-appliance (config) # serial enable
Serial Console enabled.
gigavue-appliance (config) #

Network Controls

Overview of IP Filter

The GigaVUE-OS Appliance allows the administrator to drop undesired connections from the network received on the management interface. It prevents unauthorized access to and from the interface. For example, you can restrict a syslog server that can communicate with the GigaVUE Appliance.

An IP filter is a chain of rules for the treatment of packets. It comprises of the following chains:

The Chain that is to be applied to the packet is determined by its source and destination. For example, a user connecting to the GigaVUE appliance using SSH will have the INPUT Chain and its rules applied to the session. A user logged into the GigaVUE appliance who is trying to connect from the GigaVUE appliance to a remote system will have the OUTPUT Chain and its rules applied to the session.

Each of the above Chains has a set of rules which are processed in order.

The INPUT Chain has a policy set to DROP. If there is no match in the rules for the packets, then the packets will be dropped.

There are six rules in this Chain. The function of each rule is:

  1. Accepts all ICMP packets from any source to any destination.
  2. Accepts all IGMP packets from any source to any destination.
  3. Accepts all the packets where there is an established or related session. For example, accepting packets in both directions of a flow ( SSH Client to GigaVUE Appliance / GigaVUE Appliance to SSH Client).
  4. Allows all communications for the loopback (lo) interface.
  5. Accepts all communications from the subnet 12.00.1.0/24 to any destination.
  6. Accepts all communications to the subnet 12.00.1.0/24 from any destination.

Rules 5 and 6 allow connections from the subnet 12.00.1.0/24. This is being used internally within the GigaVUE Appliance to allow the Management Board to communicate with GigaSMART. The traffic to/from these IP's do not appear on the physical network and that these connections between the Management Board and GigaSMART are authenticated.

There is a Policy associated with each Chain, which can be set to ACCEPT or DROP the targets. If the Policy is set to DROP, and there are no matches for the incoming packets in the rules of the Chain, then the packet will be dropped. If the Policy is set to ACCEPT and if there are no matches for the incoming packets in the rules of the Chain, then the packet will be accepted.

For more information on IP Security Chain, refer the IP Filter Chains for Security topics in the GigaVUE-OS CLI Reference Guide.

Best Practices for Security Hardening

The following sections list best practices for security:

Use of SNMPv1 and SNMPv2 are Not Recommended

Using SNMPv1 and SNMPv2 are not recommended because they authenticate using unencrypted, plaintext community strings.

Using SNMPv3 is recommended for access to the SNMP agent, as well as to SNMP traps. SNMPv3 authenticates using encrypted community strings. For more information, refer to Use SNMP.

Use of Self-Signed Certificates are Not Recommended

Using self-signed TLS/SSL certificates are not recommended.

Certificates generated by a third party certification authority are recommended because they are issued by a Certification Authority (CA). Refer to SHA2-Based Signature in TLS/SSL Server X.509 Certificate for how to obtain a third party certificate.

Use of FTP and TFTP are Not Recommended

Using FTP or TFTP for file transfers is not recommended.

Using SFTP, SCP, or HTTPS is recommended for uploading or downloading files to or from GigaVUE Cloud Suite nodes.

Use of Enhanced Cryptography Mode to Run Scans is Recommended

Using secure cryptography mode to run scans is recommended.

Refer to Configure Enhanced Cryptography Mode for more information.

When a scan includes password brute force testing, it is recommended to disable locking users due to many attempts.

To disable lockout of accounts based on failed authentication attempts, select Settings > Authentication > AAA. Under Lockout, unselect Enable Lockout. For more information about Lockout, refer to Lockout.

GigaVUE-OS Security Hardening

To harden the GigaVUE Cloud Suite operating system, GigaVUE-OS, against security threats, Gigamon fixes known vulnerabilities, keeps up-to-date any OS components that provide remote access (such as Apache, SSH, SSHD, and OpenSSL), and analyzes the system for attack vectors.

GigaVUE Cloud Suite nodes run the GigaVUE-OS, which is hardened against the following:

Specific Hardening Areas

SHA2-Based Signature in TLS/SSL Server X.509 Certificate

Certificates generated by a third party certification authority are more secure than self-signed certificates. High strength ciphers with key lengths equal to or greater than 112 bits are also more secure than ciphers with less than 112 bits.

GigaVUE-OS supports TLS/SSL server X.509 certificates, including SHA2-256 and SHA2-512-based certificates, as well as SHA1-based certificates.

However, SHA1 has known weaknesses that expose it to collision attacks, which may allow an attacker to generate additional X.509 certificates with the same signature as the original.

Therefore, when a third party certificate is requested, SHA2-256 or SHA2-512 should be requested as the signature algorithm, and not SHA1.

Obtain Third Party Certificate

To obtain a third party certificate, on Linux or Linux app (such as Cygwin), generate a private key as follows:

openssl req -new -key privkey.pem -out cert.csr

The file, cert.csr is sent to a third party certificate authority, which will generate a certificate.

Supported Ciphers

The ciphers supported with TLS v1.2 are listed in the following table:

Table 1: Supported Ciphers with TLS v1.2.
Authenticated Encryption with Additional Data (AEAD) Ciphers
TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384 (0xc030)
TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256 (0xc02f)
TLS_DHE_RSA_WITH_AES_256_GCM_SHA384 (0x9f)
TLS_DHE_RSA_WITH_AES_128_GCM_SHA256 (0x9e)

ICMP Timestamp Response

The GigaVUE-OS does not respond to Internet Control Message Protocol (ICMP) timestamp requests.

The response to such a request is an ICMP timestamp response. The response can contain the date and time from a GigaVUE Cloud Suite node, which could be used to exploit weak time-based random number generators in other services on the node, therefore this is disabled.

In addition, ICMP echo broadcasts, including timestamp requests and responses, are disabled, since ICMP echo requests may be used for Denial of Service (DoS) attacks, such as packet flooding.

TCP Timestamp Response

The GigaVUE-OS does not respond to Transmission Control Protocol (TCP) timestamp requests.

The response to such a request is a TCP timestamp response. The response can be used to approximate the uptime of the GigaVUE Cloud Suite node, which can then be used in DoS attacks.

In addition, some operating systems can be fingerprinted based on the behavior of their TCP timestamps, therefore this is disabled.

Non-Standard SNMP Community Name

Gigamon does not recommend using the default SNMP community string, public. It recommends using a non-standard SNMP community name, gigamon.

For steps to protect against SNMP vulnerabilities, refer to Recommendations for Vulnerabilities in the Use SNMP chapter.

Additional Sources of Information

This appendix provides additional sources of information. Refer to the following sections for details:

Documentation

This table lists all the guides provided for GigaVUE Cloud Suite software and hardware. The first row provides an All-Documents Zip file that contains all the guides in the set for the release.

NOTE: In the online documentation, view What's New to access quick links to topics for each of the new features in this Release; view Documentation Downloads to download all PDFs.

Table 1: Documentation Set for Gigamon Products

GigaVUE Cloud Suite 6.6 Hardware and Software Guides

DID YOU KNOW? If you keep all PDFs for a release in common folder, you can easily search across the doc set by opening one of the files in Acrobat and choosing Edit > Advanced Search from the menu. This opens an interface that allows you to select a directory and search across all PDFs in a folder.

Hardware

how to unpack, assemble, rack-mount, connect, and initially configure ports the respective GigaVUE Cloud Suite devices; reference information and specifications for the respective GigaVUE Cloud Suite devices

Hardware Installation Guides
GigaVUE-HC1 Hardware Installation Guide
GigaVUE-HC2 Hardware Installation Guide
GigaVUE-HC3 Hardware Installation Guide
GigaVUE-HC1-Plus Hardware Installation Guide
GigaVUE-HCT Hardware Installation Guide
GigaVUE-TA25 Hardware Installation Guide
GigaVUE-TA25E Hardware Installation Guide
GigaVUE-TA100 Hardware Installation Guide
GigaVUE-TA200 Hardware Installation Guide
GigaVUE-TA200E Hardware Installation Guide
GigaVUE-TA400 Hardware Installation Guide
GigaVUE-OS Installation Guide for DELL S4112F-ON
G-TAP A Series 2 Installation Guide
GigaVUE M Series Hardware Installation Guide
GigaVUE-FM Hardware Appliances Guide
Software Installation and Upgrade Guides
Software Installation and Upgrade Guides
GigaVUE-FM Installation, Migration, and Upgrade Guide
GigaVUE-OS Upgrade Guide
GigaVUE V Series Migration Guide
Fabric Management and Administration Guides
Fabric Management and Administration Guides
GigaVUE Administration Guide
covers both GigaVUE-OS and GigaVUE-FM
GigaVUE Fabric Management Guide
how to install, deploy, and operate GigaVUE-FM; how to configure GigaSMART operations; covers both GigaVUE-FM and GigaVUE-OS features
Cloud Guides

how to configure the GigaVUE Cloud Suite components and set up traffic monitoring sessions for the cloud platforms

Cloud Guides
GigaVUE V Series Applications Guide
GigaVUE V Series Quick Start Guide
GigaVUE Cloud Suite Deployment Guide - AWS
GigaVUE Cloud Suite Deployment Guide - Azure
GigaVUE Cloud Suite Deployment Guide - OpenStack
GigaVUE Cloud Suite Deployment Guide - Nutanix
GigaVUE Cloud Suite Deployment Guide - VMware (ESXi)
GigaVUE Cloud Suite Deployment Guide - VMware (NSX-T)
GigaVUE Cloud Suite Deployment Guide - Third Party Orchestration
Universal Cloud Tap - Container Deployment Guide
Gigamon Containerized Broker Deployment Guide
GigaVUE Cloud Suite for Nutanix Guide—GigaVUE-VM Guide
GigaVUE Cloud Suite Deployment Guide - AWS Secret Regions
GigaVUE Cloud Suite Deployment Guide - Azure Secret Regions
Reference Guides
Reference Guides
GigaVUE-OS CLI Reference Guide
library of GigaVUE-OS CLI (Command Line Interface) commands used to configure and operate GigaVUE HC Series and GigaVUE TA Series devices
GigaVUE-OS Security Hardening Guide
GigaVUE Firewall and Security Guide
GigaVUE Licensing Guide
GigaVUE-OS Cabling Quick Reference Guide
guidelines for the different types of cables used to connect Gigamon devices
GigaVUE-OS Compatibility and Interoperability Matrix
compatibility information and interoperability requirements for Gigamon devices
GigaVUE-FM REST API Reference in GigaVUE-FM User's Guide
samples uses of the GigaVUE-FM Application Program Interfaces (APIs)
Release Notes
Release Notes
GigaVUE-OS, GigaVUE-FM, GigaVUE-VM, G-TAP A Series, and GigaVUE Cloud Suite Release Notes
new features, resolved issues, and known issues in this release ; important notes regarding installing and upgrading to this release

NOTE: Release Notes are not included in the online documentation.

NOTE: Registered Customers can log in to My Gigamon to download the Software and Release Notes from the Software and Docs page on to My Gigamon. Refer to How to Download Software and Release Notes from My Gigamon.

In-Product Help
In-Product Help
GigaVUE-FM Online Help
how to install, deploy, and operate GigaVUE-FM.

How to Download Software and Release Notes from My Gigamon

Registered Customers can download software and corresponding Release Notes documents from the Software & Release Notes page on to My Gigamon. Use the My Gigamon Software & Docs page to download:

To download release-specific software, release notes, or older PDFs:

  1. Log in to My Gigamon.
  2. Click on the Software & Release Notes link.
  3. Use the Product and Release filters to find documentation for the current release. For example, select Product: "GigaVUE-FM" and Release: "6.6," enter "pdf" in the search box, and then click GO to view all PDF documentation for GigaVUE-FM 6.6.xx.

NOTE: My Gigamon is available to registered customers only. Newer documentation PDFs, with the exception of release notes, are all available through the publicly available online documentation.

Documentation Feedback

We are continuously improving our documentation to make it more accessible while maintaining accuracy and ease of use. Your feedback helps us to improve. To provide feedback and report issues in our documentation, send an email to: documentationfeedback@gigamon.com

Please provide the following information in the email to help us identify and resolve the issue. Copy and paste this form into your email, complete it as able, and send. We will respond as soon as possible.

Documentation Feedback Form

About You
Your Name
Your Role
Your Company
For Online Topics
Online doc link(URL for where the issue is)
Topic Heading(if it's a long topic, please provide the heading of the section where the issue is)

How can we improve?

Describe the issueDescribe the error or issue in the documentation. (If it helps, attach an image to show the issue.)
How can we improve the content?Be as specific as possible.
Any other comments?

Contact Technical Support

For information about Technical Support: Go to Settings > Support > Contact Support in GigaVUE-FM.

You can also refer to https://www.gigamon.com/support-and-services/contact-support for Technical Support hours and contact information.

Email Technical Support at support@gigamon.com.

Contact Sales

Use the following information to contact Gigamon channel partner or Gigamon sales representatives:

Telephone: +1.408.831.4025

Sales: inside.sales@gigamon.com

Partners: www.gigamon.com/partners.html

Premium Support

Email Gigamon at inside.sales@gigamon.com for information on purchasing 24x7 Premium Support. Premium Support entitles you to round-the-clock phone support with a dedicated Support Engineer every day of the week.

The VÜE Community

The VÜE Community is a technical site where Gigamon users, partners, security and network professionals and Gigamon employees come together to share knowledge and expertise, ask questions, build their network and learn about best practices for Gigamon products.

Visit the VÜE Community site to:

The VÜE Community is a great way to get answers fast, learn from experts and collaborate directly with other members around your areas of interest.

Register today at community.gigamon.com

Questions? Contact our Community team at community@gigamon.com.

Glossary

D

decrypt list
need to decrypt (formerly blacklist)

decryptlist
need to decrypt - CLI Command (formerly blacklist)

drop list
selective forwarding - drop (formerly blacklist)

F

forward list
selective forwarding - forward (formerly whitelist)

L

leader
leader in clustering node relationship (formerly master)

M

member node
follower in clustering node relationship (formerly slave or non-master)

N

no-decrypt list
no need to decrypt (formerly whitelist)

P

nodecryptlist
no need to decrypt- CLI Command (formerly whitelist)

primary source
root timing; transmits sync info to clocks in its network segment (formerly grandmaster)

R

receiver
follower in a bidirectional clock relationship (formerly slave)

S

source
leader in a bidirectional clock relationship (formerly master)

Models: GigaVUE Active Network Tap, GigaVUE, Active Network Tap, Network Tap, Tap

File Info : application/pdf, 18 Pages, 234.50KB

PDF preview unavailable. Download the PDF instead.

GigaVUE-OS-Hardening-Guide-v66

References

madbuild

Related Documents

PreviewGigamon GigaVUE-TA100 Hardware Installation Guide
Comprehensive installation guide for the Gigamon GigaVUE-TA100 Traffic Aggregator, detailing hardware setup, connections, configuration, and safety procedures for network visibility and analytics.
PreviewGigaVUE-OS CLI Reference Guide v5.14
This comprehensive reference guide details the GigaVUE-OS Command-Line Interface (CLI), providing essential information for configuring and managing Gigamon's network visibility platform, including GigaVUE-HC and TA series nodes.
PreviewGigamon GigaVUE-FM Installation and Upgrade Guide v5.15
This guide provides comprehensive instructions for installing and upgrading Gigamon's GigaVUE-FM Fabric Manager (version 5.15) across various platforms including VMware ESXi, AWS, Azure, MS Hyper-V, and KVM.
PreviewGigaVUE-OS CLI Reference Guide
A comprehensive guide to the GigaVUE-OS Command Line Interface (CLI), detailing commands, syntax, and configuration examples for Gigamon visibility platform nodes.
PreviewGigaVUE-TA25E Hardware Installation Guide
This guide provides detailed instructions for the installation of the Gigamon GigaVUE-TA25E hardware, covering setup, connections, and configuration.
PreviewGigamon GigaSMART Intelligent Traffic Handling Data Sheet
Explore Gigamon's GigaSMART solution for intelligent traffic handling, enhancing network visibility, traffic management, and tool efficiency. Learn about key benefits, features, and ordering information for GigaSMART applications across Gigamon's hardware platforms.
PreviewGigamon GigaVUE-FM & GigaVUE-OS Factory Reset Guidelines
Comprehensive guidelines for performing a factory reset on Gigamon GigaVUE-FM and GigaVUE-OS devices. Learn the procedures for clearing configurations, logs, licenses, and data to restore devices to their default state.
PreviewGigaVUE V Series Applications Guide
A comprehensive guide detailing the configuration and use of Gigamon's GigaVUE V Series Applications, including Application Intelligence, De-duplication, GENEVE Decapsulation, Header Stripping, Load Balancing, Masking, SSL Decrypt, PCAPng, 5G-SBI, and 5G-Cloud applications for network traffic analysis and optimization.