
Square D LAD4RC3U 110 to 240 VAC RC Circuit Type Suppressor Module | Crawford Electric Supply
Square D LC1K0610F7 600 VAC 6 Amp 3-Pole 1NO Screw Terminal Full Voltage Non-Reversing IEC Contactor | Crawford Electric Supply
CONTACTORS 18 AND STARTERS-IEC TeSys island Load Management System TeSys Deca Series 9--150 Amperes TeSys Giga Series 115--800 Amperes TeSys Ultra Combination Motor Controllers Scan here to access our online digital easy motor control selectors Table of Contents Section 18 Contactors and Starters-IEC TeSys Selection Overview 18-2 Solutions that enhance machine intelligence Two-Component Motor Circuit Solutions to 520 amps 18-2 18-4 Digital Motor Control Solution 18-5 TeSys island Load Management System 18-5 Contactors and Overload Relays 18-8 TeSysTM K Contactors and Overload Relays TeSysTM K Non-Reversing Mini-Contactors TeSysTM K Overload Relays TeSysTM K Reversing Mini-Contactors TeSysTM Deca Series 9150 Amperes TeSysTM Deca Non-Reversing Contactors TeSysTM Deca Overload Relays TeSysTM Deca Reversing Contactors TeSysTM Giga Series 115-800 Amperes TeSysTM Giga Non-Reversing Contactors TeSysTM Giga Overload Relays TeSysTM Giga Reversing Contactors TeSysTM F Contactors and Overload Relays TeSysTM F Non-Reversing Contactors Contactor Accessories 18-8 18-8 18-9 18-9 18-11 18-11 18-12 18-14 18-15 18-15 18-16 18-16 18-17 18-17 18-18 TeSysTM K Contactors TeSysTM Deca and F Contactors TeSysTM Deca Contactors TeSysTM Giga Contactors Overload Relay Accessories 18-18 18-19 18-21 18-24 18-28 TeSysTM Deca Overload Relays TeSysTM Giga Overload Relay Motor Starters and Protectors 18-28 18-29 18-30 TeSysTM Ultra Combination Motor Controllers TeSysTM Deca Manual Motor Controllers TeSysTM Deca Enclosed Starters TeSysTM LS1 Fuse Holders Soft Starter Module ATSU01 18-30 18-34 18-39 18-41 18-42 ATSU01 AltistartTM and TeSysTM Ultra Replacement Parts 18-42 18-43 TeSysTM Deca Series TeSysTM Giga Series Wiring Systems 18-43 18-44 18-45 TeSysTM AK5 Panel Busbar System Dimensions 18-45 18-46 © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-1 TeSys Selection Overview Solutions that enhance machine intelligence Refer to Catalog MKTED210011EN www.se.com/us TeSys Control Solutions TeSys offers solutions for a variety of common control applications, including small to large loads, motor and non-motor loads, in various forms to meet customers specific needs. Basic solutions offer traditional approaches that meet compact, cost-effective, and large HP applications. TeSys also equips OEMs and System Integrators with EcoStruxure Machine connected product solutions that are IoT ready offers to help enhance the intelligence of machinery and equipment, helping to recognize and address potential issues before stoppage and decrease unplanned downtime. Table 18.1: Solutions that enhance machine intelligence Solution 1 -- TeSysTM island as group motor Solution 2 -- TeSys island with individual protection Solution 3 -- TeSys Ultra (Type E self-protected) using Multi-function trip unit & communication module or using pre-trip alarm function module Solution 4 -- TeSys T overload relay Solution 5 -- TeSys GV4PB, GV5PB, GV6PB with SDx Module Best Practice Scenario Benefits Circuit Protection Motor Control Motor Overload Protection Load Types Max HP 480V SCCR Available data Communication Ideal for panels with multiple loads. Single bus coupler serves as connection to PLC, manages logic and configuration for starters. See load, device and system performance. Set alarms to anticipate maintenance and optimize performance. Circuit breaker or fuse protection group TeSys island load management system with or without TeSys Deca Manual Motor Controllers Motor, resistive/non-inductive, isolation 40 HP basic 5 kA up to high 50 kA (with GV) Device status/performance Load performance including alarms Voltage, Energy & Power Ethernet IP, Modbus TCP, Profinet, Profibus Ideal for panels with multiple loads. Single bus coupler serves as connection to PLC, manages logic and configuration for starters. See load, device and system performance. Set alarms to anticipate maintenance and optimize performance. Circuit breaker or fuse TeSys island load management system Motor, resistive/non-inductive, isolation 40 HP high, to 100 kA Device status/performance Load performance including alarms Voltage, Energy & Power Ethernet IP, Modbus TCP, Profinet, Profibus Ideal for panels with one or two motors. Each starter communicates directly to PLC. See load performance. Set alarms to anticipate maintenance and optimize performance. TeSys Ultra (applied as Type E self protected), using advanced trip unit/ function modules Motor loads only 20 HP High, to 65 kA Load performance including alarms ModbusTM, CANopen, DeviceNetTM, ProfibusTM Ideal for larger HP. Each overload relay communicates directly to PLC. See load performance. Set alarms to anticipate maintenance and optimize performance. Breaker or fuse TeSys Deca or Giga contactors TeSys T overload relay Motor loads only 500 HP (up to 810 amps) Depends on configuration Load performance including alarms Voltage & Power ModbusTM, CANopen, DeviceNetTM, ProfibusTM, Ethernet/IP, and Modbus/ TCP Ideal for adding intelligence using a simple NO/NC pre-trip alarm contact -- Use of PLC to receive/ interpret data not required. Pre-trip alarm NO/NC contact alerts prior to trip, enabling proactive actions to minimize downtime or alert operators GV4PB, GV5PB, GV6PB TeSys Deca or Giga contactor (included in GV*PB) Motor loads only 450 HP (up to 520 amps) Depends on configuration Pre-trip alarm (via NO/NC contact) None 18 CONTACTORS AND STARTERS-IEC 18-2 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us Solutions that enhance machine intelligence Refer to Catalog MKTED210011EN TeSys Selection Overview Table 18.2: Basic -- Traditional motor control solution Solution 1 -- Two component solution Type F -- up to 65 amps Motor Protective Circuit Breakers + contactor - up to 520 amps Solution 2 -- Single component solution Type E -- up to 32 amps Solution 3 -- Group Motor solution up to 65 amps Solution 5 -- Three component solution (Breaker/ fuse, contactor & overload relay) Solution 6 -- Type D solution (Motor circuit protector, contactor & overload relay) Solution 7 -- Non-motor load solution (Breaker/fuse + contactor) Best Practice Scenario Benefits Circuit Protection Motor Control Motor Overload Protection Load Types Most cost effective, high SCCR solution Simple, twocomponent solution, cost effective, fast power wiring using bus bars Simple, twocomponent solution, cost effective for larger HP motors Most compact, also ideal for critical uptime appllcations resetable after a short-circuit with no component replacement), high SCCR solution Single component solution, Type 2 rated (minimize downtime after shortcircuit) Few components, 480V delta rated cost effective solution ideal for panels with many motor loads (single breaker for multiple starters) TeSysTM Deca GV2P, GV3P (applied as Type F with contactor) Tesys Deca LC1D TeSysTM Giga GV4PB, GV5PB, GV6PB (UL 489) TeSys Deca LC1D or Giga LC1G TeSys Ultra, with basic trip unit PowerPact or Multi9 (UL 489) or fuses TeSys Deca LC1D (included in GV) (included in GV) TeSys Deca GV Motor loads only Motor loads only Motor loads only Motor loads only three-component solution, ideal for higher HPs or high SCCR ideal for pumping applications, includes adjustable motor in rush sensitivity basic solution, ideal for 480V delta applications, resetable after breaker trip adjustable motor inrush sensitivity, ideal for pumping applications PowerPact or Multi9 (UL 489) or TeSys DF, LS1 fuseholder, GS disconnect with fuses TeSys Deca LC1D or TeSys Giga LC1G TeSys BV4 (UL 489) TeSys Deca LC1D TeSys Deca LR or TeSys Giga LR9G TeSys Deca LR Motor loads only Motor loads only ideal for non-motor loads ideal for non-motor loads PowerPact or Mulit9 (UL 489) or TeSys DF, LS1 fuseholder, GS disconnect with fuses TeSys Deca LC1D or TeSys Giga LC1G -- Resistive/non-inductive, isolation CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-3 TeSys Selection Overview Two-Component Motor Circuit Solutions to 520 amps Refer to Catalog MKTED210011EN www.se.com/us Two-Component Motor Circuit Solutions to 520 Amps Simplify design, panel space and installation with TeSysTM high SCCR solution that use only two components that make up an entire branch circuit up to 520 amps. These twocomponent solutions are UL compliant using either a Type F combination motor controller rating or a UL 489 rating. For additional solutions and ratings, see Motor Control Solutions for North America data bulletin 8536DB0901. TeSysTM Deca Series Table 18.3: Quick selection table for TeSysTM twocomponent motor circuit solutions 200 V 3P 230 V 3P 460 V 3P HP FLA[2] HP FLA[2] HP FLA[2] GV Ref -- -- -- -- -- -- -- -- 1/2 2.5 1/2 2.2 -- -- -- -- 3/4 3.7 3/4 3.2 1 4.6 1 4.2 -- -- 1 1/2 6 1 1/2 6.9 2 6.8 2 7.8 -- -- -- -- 3 9.6 3 11 -- -- -- -- -- -- 5 17.5 5 15.2 -- -- 7 1/2 22 7 1/2 25.3 -- -- -- -- 10 28 10 32.2 -- -- -- -- 15 42 15 48 20 54 20 62.1 25 68 25 78.2 30 80 30 92 -- -- -- -- 40 104 40 120 -- -- -- -- 50 130 50 150 60 154 60 177 75 192 75 221 100 248 100 285 125 312 125 359 150 360 150 414 200 480 200 552 -- -- 1/2 3/4 1 1 1/2 2 3 ---- -- 5 -- 7 1/2 10 -- 15 -- 20 25 30 40 50 60 -- 75 -- 100 125 150 200 250 300 400 500 1.1 1.6 2.1 3 3.4 4.8 ---- -- 7.6 -- 11 14 -- 21 -- 27 34 40 52 65 77 -- 96 -- 124 156 180 240 302 361 477 590 GV2P06 GV2P06 GV2P07 GV2P08 GV2P08 GV2P10 GV2P10 GV2P14 GV2P14 GV2P16 GV2P16 GV2P16 GV2P20 GV2P21 GV2P22 GV3P32 GV3P40 GV3P50 GV3P65 GV4PB115S GV4PB115S GV4PB115S GV5PB150S GV5PB150S GV5PB250S GV5PB250S GV5PB250S GV6PB400S GV6PB400S GV6PB600S GV6PB600S GV6PB600S TeSysTM Giga Series Overload Dial Range (A) 1 to 1.6 1 to 1.6 1.6 to 2.5 2.5 to 4 2.5 to 4 4 to 6.3 4 to 6.3 6 to 10 6 to 10 9 to 14 9 to 14 9 to 14 13 to 18 17 to 23 20 to 25 23 to 32 30 to 40 37 to 50 48 to 65 65 to 115 65 to 115 65 to 115 58 to 130 58 to 130 114 to 217 114 to 217 114 to 217 190 to 348 190 to 348 312 to 520 312 to 520 312 to 520 Contactor Ref [1] LC1D09G7 LC1D09G7 LC1D09G7 LC1D09G7 LC1D09G7 LC1D09G7 LC1D09G7 LC1D12G7 LC1D12G7 LC1D12G7 LC1D18G7 LC1D18G7 LC1D18G7 LC1D25G7 LC1D25G7 LC1D32G7 LC1D40AG7 LC1D50AG7 LC1D65AG7 LC1D80G7 LC1D80G7 LC1D115G7 LC1D115G7 LC1D150G7 LC1D150G7 LC1G185 LC1G225 LC1G265 LC1G330 LC1G400 LC1G500 LC1G630 SCCR 480Y as applied with specified protection 65 kA[3] 65 kA[3] 65 kA[3] 65 kA[3] 65 kA[3] 65 kA[3] 65 kA[3] 65 kA[3] 65 kA[3] 50 kA[4] 50 kA[4] 50 kA[4] 50 kA[4] 50 kA[4] 50 kA[4] 65 kA[5] 65 kA[5] 65 kA[5] 65 kA[5] 65 kA 65 kA 65 kA 65 kA 65 kA 65 kA 100 kA 100 kA 100 kA 100 kA 65 kA 65 kA 100 kA 18 CONTACTORS AND STARTERS-IEC [1] Add coil suffix to complete reference part number (See Table 18.23 TeSys Deca Coil Voltage Codes , page 18-11 for LC1D and TeSys Giga Contactors -- 3-Pole Standard Version, page 18-15 and Table 18.30 TeSys Giga Contactors -- 3-Pole Advanced Version, page 18-15 for LC1F). For example, an LC1D09G7 includes a 120 Vac coil. [2] Motor Full Load Amp Sizes are based on NEC Table 430.250. [3] Requires use of GV1G09 or GV2GH7 line spacer for Type F rating. SCCR is 100 kA at 480Y with or without use of GV2G busbar links. [4] Requires use of GV1G09 or GV2Gh7 line spacer for Type F rating. SCCR is 42 kA at 480Y when using GV2G busbar links. [5] Requires use of GV3G66 line spacer and GVAM11 short-circuit signaling contact for Type F rating. 18-4 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSys island Load Management System Refer to Catalog MKTED210011EN Digital Motor Control Solution Island Concept TeSys island is an innovative digital load management solution--providing data for higher machine efficiency and ease of servicing, and allowing faster time to market. TeSys island is a modular, multifunctional system providing integrated functions inside an automation architecture, primarily for the direct control and management of low-voltage loads. TeSys island can switch, help protect, and manage motors and other electrical loads up to 40 hp, 80 A installed in an electrical control Panel. This system is designed around the concept of TeSysTM avatars. These avatars: · are the functional object representing a logical function of the physical module with pre-defined logic · determine the configuration of the island. The logical aspects of the island are managed with software tools, covering all phases of product and application lifecycle: design, engineering, commissioning, operation, and maintenance. 1 Bus Coupler 2 Analog I/O module 3 Digital I/O module 4 Voltage interface module 5 Power interface module 6 Standard Starter 7 SIL Starter 9 SIL interface module The physical island consists of a set of devices installed on a single DIN rail controlling loads, monitoring data, diagnostics information and connected together with a ribbon cable providing the internal communication between modules. The external communication with the automation environment is made via a single coupler module, and the island is seen as a single node on the network. The other modules include starters, power interface modules, analog and digital I/O modules, voltage interface modules, and SIL interface modules, covering a wide range of operational functions. CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-5 Digital Motor Control Solution TPRBCEIP TeSys island Load Management System Refer to Catalog LVCATISL www.se.com/us Product References The TeSys island load management system consists of a bus coupler along with other starters and modules as needed to build an "island" of load management, monitoring & control functions. It is recommended to use the online EcoStruxure Motor Control Configurator to ensure proper application and sizing. Scan here to access our online EcoStruxure Motor Control Configurator Table 18.4: Bus Couplers Designation TeSys island Bus Coupler Upstream PLC protocol EtherNet/IPModbus TCP PROFINET PROFIBUS Service Port protocol Ethernet TCP/IP Ethernet TCP/IP Ethernet TCP/IP Product Reference TPRBCEIP TPRBCPFN TPRBCPFB Weight (kg) 0.204 0.204 0.204 Table 18.5: 3-Pole Starters Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 1/3 1 2 2 5 2 3 7 1/2 7 1/2 15 2 5 10 10 20 5 10 20 20 40 5 10 20 20 40 575 V 5 20 25 50 50 Continuous Current Rating (A) 15 30 40 80 80 Product Reference TPRST009 TPRST025 TPRST038 TPRST065 TPRST080 Weight (kg) 0.656 0.718 0.718 1.248 1.248 TPRST009 18 CONTACTORS AND STARTERS-IEC 18-6 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSys island Load Management System Refer to Catalog LVCATISL Digital Motor Control Solution TPRS025 TPRSM001 Table 18.6: 3-Pole SIL Starters Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 575 V 1/3 1 2 2 5 5 2 3 7 1/2 7 1/2 15 20 2 5 10 10 20 25 5 10 20 20 40 50 5 10 20 20 40 50 Continuous Current Rating (A) 15 30 40 80 80 Product Reference TPRSS009 TPRSS025 TPRSS038 TPRSS065 TPRSS080 Weight (kg) 0.656 0.718 0.718 1.248 1.248 Table 18.7: 3-Pole PIM Starters Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 1/3 1 2 2 5 2 5 10 10 20 5 10 20 20 40 575 V 5 25 50 Table 18.8: SIL Interface Module Designation TeSys island SIL interface module (SIM) Voltage (Vdc) 24 Continuous Current Rating (A) 15 40 80 Product Reference TPRPM009 TPRPM038 TPRPM080 Weight (kg) 0.255 0.255 0.425 Product Reference TPRSM001 Weight (kg) 0.159 Table 18.9: Voltage Interface Module (VIM) Designation TeSys island Voltage interface module (SIM) Phase 1P/3P Voltage (V) 100 to 690 Frequency (Hz) 5060 Product Reference TPRVM001 Weight (kg) 0.159 Table 18.10: Digital I/O Module Designation Input Vdc TeSys island DG--Digital 4I/2O Module 24 Output A / Vdc Frequency (Hz) Product Reference 0.5 / 24 5060 TPRDG4X2 Weight (kg) 0.136 Table 18.11: Analog I/O Module Designation TeSys island--Analog 2I/2O Module Inputs mA dc Vdc 020 10 to +10 4020 010 Output mA dc Vdc 020 10 to +10 420 010 Product Reference TPRAN2X1 Weight (kg) 0.172 TPRVM001 TPRDG4X2 CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-7 Contactors and Overload Relays TeSysTM K Contactors and Overload Relays Refer to Catalog MKTED210011EN TeSysTM K Non-Reversing Mini-Contactors www.se.com/us LC1K09 LP4K09 Table 18.12: Mini-Contactors with AC Operating Coils Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 575 V Maximum Current (A) Inductive AC3 Resistive AC1 0.5 1 1.5 1.5 3 3 6 20 0.5 1.5 2 3 5 5 9 20 1 2 3 3 7.5 10 12 20 4-Pole Mini Contactor 1/2 1.5 2 3 5 5 9 20 1 2 3 3 7.5 10 12 20 4-Pole Mechanically Interlocked Contactors 1/2 1.5 2 3 5 5 9 20 1 2 3 3 7.5 10 12 20 Continuous Current Rating (A) 10 20 20 20 20 20 20 Type of Connection Screw-clamp Screw-clamp Screw-clamp Screw-clamp Screw-clamp Screw-clamp Screw-clamp Auxiliary Contacts N.O. 1 -- 1 -- 1 -- N.C. -- 1 -- 1 -- 1 4 -- 2 2 4 -- Catalog Number [1][2] LC1K0610 LC1K0601 LC1K0910 LC1K0901 LC1K1210 LC1K1201 LC1K09004 LC1K09008 LC1K12004 4 -- LC2K09004 4 -- LC2K12004 Table 18.13: Coil Voltage Codes for AC Contactors Vac 50/60 Hz Code 24 110 120 B7 F7 G7 230/240 U7 Table 18.14: Mini-Contactors with 24 Vdc Operating Coils Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 575 V Maximum Current (A) Inductive Resistive AC3 AC1 0.5 1 1.5 1.5 3 3 6 20 Continuous Current Rating (A) 10 0.5 1.5 2 3 5 5 9 20 20 1 2 3 3 7.5 10 12 20 20 4-Pole Mini Contactor 1/2 1.5 2 3 5 5 9 20 20 1 2 3 3 7.5 10 12 20 20 4-Pole Mechanically Interlocked Contactors 1/2 1.5 2 3 5 5 9 20 20 1 2 3 3 7.5 10 12 20 20 Type of Connection Screw-clamp Screw-clamp Screw-clamp Screw-clamp Screw-clamp Screw-clamp Screw-clamp Auxiliary Contacts N.O. 1 -- 1 -- 1 -- N.C. -- 1 -- 1 -- 1 4 -- 2 2 4 -- 4 -- 4 -- Catalog Number [2] LP1K0610BD LP1K0601BD LP1K0910BD LP1K0901BD LP1K1210BD LP1K1201BD LP1K09004BD LP1K09008BD LP1K12004BD LP2K09004BD LP2K129004BD Table 18.15: Mini-Contactors with Low-Consumption 24 Vdc Operating Coil (includes built-in transient suppression) [3] Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 0.5 1 1.5 1.5 3 0.5 1.5 2 3 5 1 2 3 3 7.5 575 V 3 Maximum Current (A) Continuous Current Inductive AC3 Resistive AC1 Rating (A) 6 20 10 5 9 20 20 10 12 20 20 Type of Connection Screw-clamp Screw-clamp Screw-clamp Auxiliary Contacts N.O. 1 -- 1 -- 1 -- N.C. -- 1 -- 1 -- 1 Catalog Number [2] LP4K0610BW3 LP4K0601BW3 LP4K0910BW3 LP4K0901BW3 LP4K1210BW3 LP4K1201BW3 18 CONTACTORS AND STARTERS-IEC [1] Complete the catalog number with the coil voltage from (for example LC1K0610G7). [2] For additional terminal options and coil voltage/consumption options, see Catalog MKTED210011EN. Check with local sales office for availability. [3] 1.8 W inrush. 18-8 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM K Contactors and Overload Relays Refer to Catalog MKTED210011EN Contactors and Overload Relays LR2K0316 TeSysTM K Overload Relays Table 18.16: Overload Relays for 3-Pole Contactors with Screw-Clamp Terminals Current Setting Range (A) 0.11 to 0.16 0.16 to 0.23 0.23 to 0.36 0.36 to 0.54 0.54 to 0.8 0.8 to 1.2 1.2 to 1.8 1.8 to 2.6 2.6 to 3.7 3.7 to 5.5 5.5 to 8 8 to 11.5 10 to 14 Catalog Number LR2K0301 LR2K0302 LR2K0303 LR2K0304 LR2K0305 LR2K0306 LR2K0307 LR2K0308 LR2K0310 LR2K0312 LR2K0314 LR2K0316 LR2K0321 [4] LR2K overload relays: · AC or DC protection · Ambient compensated bimetallic · Class 10 · Single phase sensitivity · Manual or auto reset · Full load current dial E164862 CCN NLDX (screw terminals) Accessories: page 18-18 Dimensions: page 18-63 E164862 CCN NLDX2 (slip-on and solder-pin terminals) LR43364 Class 3211 04 TeSysTM K Reversing Mini-Contactors LC2K0910 Table 18.17: AC Operating Coils Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 1/2 1 1.5 1.5 3 1/2 1.5 2 3 5 1 2 3 3 7.5 575 V 3 5 10 Maximum Current (A) Inductive AC3 Resistive AC1 6 20 9 20 12 20 Continuous Current Rating (A) 10 20 20 Type of Connection Screw-clamp Screw-clamp Screw-clamp Auxiliary Contacts N.O. 1 -- 1 -- 1 -- N.C. -- 1 -- 1 -- 1 Catalog Number [5][6] LC2K0610 LC2K0601 LC2K0910 LC2K0901 LC2K1210 LC2K1201 Table 18.18: Coil Voltage Codes for AC Contactors Vac 50/60 Hz Code 24 110 120 230/ 240 B7 F7 G7 U7 CONTACTORS 18 AND STARTERS-IEC [4] Not UL Listed. [5] Complete the catalog number with the coil voltage code from Table 18.18 (for example, LC2K0610G7). [6] For additional terminal options and coil options, see Catalog MKTED210011EN. Check with local sales office for availability. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-9 Contactors and Overload Relays TeSysTM K Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us LP2K0910 Table 18.19: DC Operating Coils Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 1/2 1 1.5 1.5 3 1/2 1.5 2 3 5 1 2 3 3 7.5 575 V 3 5 10 Maximum Current (A) Inductive AC3 Resistive AC1 Continuous Current Rating (A) 6 20 10 9 20 20 12 20 20 Type of Connection Screw-clamp Screw-clamp Screw-clamp Auxiliary Contacts N.O. 1 -- 1 -- 1 -- N.C. -- 1 -- 1 -- 1 Catalog Number [7] LP2K0610BD LP2K0601BD LP2K0910BD LP2K0901BD LP2K1210BD LP2K1201BD LC2K090045 Table 18.20: Coil Voltage Codes for DC Contactors Coil with integral suppression device available. Add 3 to the code required. Example: JD3 [8] Vdc Code 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD Table 18.21: Coil Voltages for DC Contactors--Low Consumption [9] Vdc Code Overload Relays: page 18-9 Accessories: page 18-18 Dimensions: page 18-63 12 JW3 24 BW3 48 EW3 72 SW3 18 CONTACTORS AND STARTERS-IEC [7] For additional terminal options and coil options, see Catalog MKTED210011EN. Check with local sales office for availability. [8] 3 W inrush. [9] 1.8 W inrush. 18-10 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Deca Series 9150 Amperes Refer to Catalog MKTED210011EN Contactors and Overload Relays TeSysTM Deca Non-Reversing Contactors CONTACTORS 18 AND STARTERS-IEC TeSys Deca Contactor The TeSysTM Deca Control Series of contactors (formerly known as TeSys D) provides high reliability and performance in a modern, modular approach. TeSys Deca contactors are UL approved to 100 hp 480 V and 160 amperes continuous current. In addition, they provide a modern appearance with new features such as multi-standard screw terminals that accommodate flat, Phillips and Pozidriv screwdrivers, as well as the new UL60335 approved plastics with greater endurance in the presence of heat or fire. Table 18.22: TeSys Deca Contactors--3 or 4 Pole, Screw Terminal Connections Maximum Horsepower Ratings Single-Phase 115 V 1/3 -- -- 1/2 -- -- 1 230 V 1 -- -- 2 -- -- 3 -- -- -- -- 2 3 -- -- -- -- 2 5 2 5 3 5 -- -- 3 7.5 5 10 -- -- 7.5 15 -- -- -- -- 7.5 15 -- -- -- -- -- -- 200 V 2 -- -- 3 -- -- 5 -- -- 7.5 -- -- 10 10 10 -- 15 20 -- 25 -- -- 25 30 40 -- Three-Phase 230 V 460 V 2 5 -- -- -- -- 3 7.5 -- -- -- -- 5 10 -- -- -- -- 7.5 15 -- -- -- -- 10 20 10 20 10 30 -- -- 15 40 20 40 -- -- 30 60 -- -- -- -- 30 60 40 75 50 100 -- -- 575 V 7.5 -- -- 10 -- -- 15 -- -- 20 -- -- 25 25 30 -- 40 50 -- 60 -- -- 60 100 125 -- Maximum Current (A) Inductive AC3 9 -- -- 12 -- -- 18 -- -- 25 -- -- 32 38 40 -- 50 65 -- 80 -- -- 95 115 150 -- Resistive AC1 20 25 32 40 50 60 80 125 200 Continuous Current Rating (A) 25 25 32 40 50 60 70 80 110 160 No. of Poles N.O. 3 4 2 3 4 2 3 4 2 3 4 2 3 3 3 4 3 3 4 3 4 2 3 3 3 4 N.C. 0 2 0 2 0 2 0 2 0 0 0 0 0 0 2 0 0 Instantaneous Auxiliary Contacts N.O. N.C. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 1 0 0 Catalog Number [10][11] LC1D09 LC1DT20 LC1D098 LC1D12 LC1DT25 LC1D128 LC1D18 LC1DT32 LC1D188 LC1D25 LC1DT40 LC1D258 LC1D32 LC1D38 LC1D40A LC1DT60A LC1D50A LC1D65A LC1DT80A LC1D80 LC1D80004 LC1D80008 LC1D95 LC1D115 LC1D150 LC1D115004 Table 18.23: TeSys Deca Coil Voltage Codes Contactor AC 50/60 Hz 24 V 110 V 120 V 240 V 480 V AC/DC 2460 V 48130 V 100250 V DC 24 V D09D38 B7 F7 G7 U7 T7 BNE EHE KUE BL D40A-D65A B7 F7 G7[12] U7 T7[12] BNE EHE KUE BBE D80D150 B7 F7 G7 U7 T7 -- -- -- BD [10] Complete the catalog number by adding the coil voltage code from Table 18.23 TeSys Deca Coil Voltage Codes , page 18-11 for example, LC1D09G7). [11] For additional terminal options and coil options, see Catalog MKTED210011EN. Check with local sales office for availability. [12] Contactors LC1D40A...80A, LC1DT60A and LC1DT80A for this coil voltage are 60 Hz only. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-11 Contactors and Overload Relays TeSysTM Deca Series 9150 Amperes Refer to Catalog MKTED210011EN www.se.com/us Table 18.24: Definite Purpose Ratings, 3-Phase, Breaking All Lines, 100,000 Cycles (Hermetic Refrigeration Compressor) Device LC1D09 (AC coil only) LC1D12 (AC coil only) LC1D18 (AC coil only) LC1D25 (AC coil only) LC1D32 (AC coil only) LC1D40A LC1D50A LC1D65A LC1D80 LC1D115 LC1D150 FLA 9 12 18 25 32 40 50 65 75 115 150 240 V 54 72 108 150 192 240 300 390 450 690 900 LRA 480 V 45 60 90 125 160 200 250 325 375 575 750 600 V 36 48 72 100 128 160 200 260 300 460 600 TeSysTM Deca Overload Relays 18 CONTACTORS AND STARTERS-IEC LRD07 Table 18.25: TeSysTM Deca Overload Relays--Ambient Compensated, Bimetallic, Direct Mounting Current Setting Range (A) 0.100.16 0.160.25 0.250.40 0.400.63 0.631 11.6 1.62.5 2.54 46 5.58 710 913 1218 1624 1724 2332 3038 9-13 12-18 17-25 23-32 30-40 37-50 48-65 17-25 23-32 30-40 37-50 48-65 5570 6380 80104 80104 95120 110140 For Direct Mounting to LC1D/LC2D... D09D38 D12D38 D18D38 D25D38 D25D38 D25D38 D32D38 D40AD65A D40AD65A D40AD65A D40AD65A D40AD65A D40AD65A D40AD65A D40D95 D40D95 [13] D40D95 [13] D50D95 [13] D50D95 [13] D65D95 D65D95 D95 D115D150 D115D150 D150 Class 10 with Single-Phase Sensitivity LRD01 LRD02 LRD03 LRD04 LRD05 LRD06 LRD07 LRD08 LRD10 LRD12 LRD14 LRD16 LRD21 LRD22 -- LRD32 LRD35 LRD313 LRD318 LRD325 LRD332 LRD340 LRD350 LRD365 LRD3322 LRD3353 LRD3355 LRD3357 LRD3359 LRD3361 LRD3363 LRD3365 LRD4365 LRD4367 LRD4369 Class 10 without Single-Phase Sensitivity LR3D01 LR3D02 LR3D03 LR3D04 LR3D05 LR3D06 LR3D07 LR3D08 LR3D10 LR3D12 LR3D14 LR3D16 LR3D21 LR3D22 -- LR3D32 LR3D35 LR3D313 LR3D318 LR3D325 LR3D332 LR3D340 LR3D350 LR3D365 LR3D3322 LR3D3353 LR3D3355 LR3D3357 LR3D3359 LR3D3361 LR3D3363 -- -- -- -- Class 20 with Single-Phase Sensitivity -- -- -- -- LRD05L LRD06L LRD07L LRD08L LRD10L LRD12L LRD14L LRD16L LRD21L -- LRD22L LRD32L -- LRD313L LRD318L LRD325L LRD332L LRD340L LRD350L LRD365L LR2D3522 LR2D3553 LR2D3555 LR2D3557 LR2D3559 LR2D3561 LR2D3563 -- -- -- -- LR9D32 Class 20 without Single-Phase Sensitivity -- -- -- -- -- -- LR3D07L LR3D08L LR3D10L LR3D12L LR3D14L LR3D21L LR3D21L -- LR3D22L LR3D32L -- -- -- -- -- -- -- -- LR3D3522 LR3D3553 LR3D3555 LR3D3557 LR3D3559 LR3D3561 LR3D3563 -- -- -- -- [13] Direct Mount to old D2 style D40 to D65 (no Everlink terminations) and to D80 and D95 only. 18-12 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us E164862 CCN NLDX TeSysTM Deca Series 9150 Amperes Refer to Catalog MKTED210011EN Contactors and Overload Relays Table 18.26: TeSys Deca Electronic Overload Relays 01 to 32 Amperes Current Setting Range (A) 0.10.5 0.42 1.68 6.432 For Direct Mounting Beneath Contactor LC1D/ LC2D D09D38 D09D38 D09D38 D09D38 Class 5/10/20/30 Selectable LR9D01 LR9D02 LR9D08 LR9D32 Table 18.27: TeSys Deca Electronic Overload Relays 60 to 150 Amperes Current Setting Range (A) For Direct Mounting Beneath Contactor LC1 60100 D115D150 90150 D115D150 TeSys Deca contactor accessories: page 18-19 TeSys Deca overload relay accessories: page 18-28 TeSys Deca replacement coils: page 18-43 Dimensions: page 18-46 to page 18-58 Class 10 LR9D5367 LR9D5369 Class 20 LR9D5567 LR9D5569 Class 10/20 Selectable LR9D67 LR9D69 LR43364 Class 3211 04 CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-13 Contactors and Overload Relays TeSysTM Deca Series 9150 Amperes Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Deca Reversing Contactors Each 3-pole device is pre-wired with line and load side power wiring for reversing applications. Each 4-pole device is prewired with load side power wiring. Table 18.28: TeSys Deca Mechanically-Interlocked Reversing Contactors Maximum Horsepower Ratings Single-Phase Three-Phase LC2D09B7 115 V 1/3 1/2 1 2 2 2 3 3 5 7.5 7.5 -- -- 230 V 1 2 3 3 5 5 5 7.5 10 15 15 -- -- 200 V 2 3 5 7.5 10 10 10 15 20 25 25 30 40 230 V 2 3 5 7.5 10 10 10 15 20 30 30 40 50 460 V 5 7.5 10 15 20 20 30 40 40 60 60 75 100 575 V 7.5 10 15 20 25 25 30 40 50 60 60 100 125 Maximum Current (A) Inductive Resistive AC3 AC1 Continuous Current Rating (A) 9 20 25 12 25 25 18 32 32 25 40 40 32 38 50 50 40 60 60 50 65 80 70 80 80 95 125 110 115 200 160 150 E164862 CCN NLDX LR43364 Class 3211 04 TeSys Deca contactor accessories: page 18-19 TeSys Deca replacement coils: page 18-43 TeSys Deca dimensions: page 18-46 to page 18-58 No. of N.O. Power Poles 3 3 3 3 3 3 3 3 3 3 3 3 3 Built In Auxiliary Contacts (per contactor) N.O. N.C. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Catalog Number [14][15][16] LC2D09 LC2D12 LC2D18 LC2D25 LC2D32 LC2D38 LC2D40A LC2D50A LC2D65A LC2D80 LC2D95 LC2D115[17] LC2D150 [17] 18 CONTACTORS AND STARTERS-IEC [14] Includes mechanical interlock without electrical contacts. Installer to complete wiring for electronically interlocking contactor operating coils by using a N.C. auxiliary contact integrated in the contactor or optional LADN or LAD8N auxiliary contact block. [15] Complete the catalog number by adding the coil voltage code from Table 18.23 TeSys Deca Coil Voltage Codes , page 18-11 (for example, LC2D09KUE). [16] For additional terminal options and coil voltage/consumption options, see Catalog MKTED210011EN. Check with local sales office for availability. [17] Includes mechanical interlock (LA9D11502) with prewired electrical contacts for interlocking contactor operating coils. 18-14 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Giga Series 115-800 Amperes Refer to Catalog MKTED210011EN Contactors and Overload Relays TeSysTM Giga Non-Reversing Contactors TeSysTM Giga Series is the newest motor control range for large motor and large load applications. This new offering brings greater performance, panel design optimization, and enhanced ease of installation. TeSys Giga contactors are available in 115 to 800 amperes in both 3-pole and 4-pole configurations. Designers can choose between the standard version and an advanced version. The advanced version provides additional features such as additional coil voltages, lower coil consumption, PLC input control, and a cable memory feature that permits maintenance without removing cables or busbar connections. For lug options, see Table 18.59 Lugs and Mounting for TeSysTM Giga Contactors and Overload Relays, page 18-24. Table 18.29: TeSys Giga Contactors -- 3-Pole Standard Version Motor rating (hp) UL 3phase 200/208 V 30 40 50 60 75 100 125 150 250 300 230/240 V 40 50 60 75 100 125 150 200 300 350 460/480V 75 100 125 150 200 250 300 400 600 700 575/600 V 100 125 150 150 200 300 400 450 700 800 General purpose continuous current (A) UL 210 230 250 290 340 390 490 630 850 900 Reference Standard version contactors AC/DC coil voltage 3-pole[18] 48130 V 100250 V LC1G115EHEN LC1G150EHEN LC1G185EHEN LC1G225EHEN LC1G115KUEN LC1G150KUEN LC1G185KUEN LC1G225KUEN LC1G265EHEN LC1G330EHEN LC1G400EHEN LC1G500EHEN LC1G265KUEN LC1G330KUEN LC1G400KUEN LC1G500KUEN LC1G630EHEN[19] LC1G630KUEN[19] LC1G800EHEN[19] LC1G800KUEN[19] TeSysTM Giga Contactors -- Standard Table 18.30: TeSys Giga Contactors -- 3-Pole Advanced Version Motor rating (hp) UL 3phase 200/208 V 30 40 50 60 75 100 125 150 230/240 V 40 50 60 75 100 125 150 200 460/480 V 75 100 125 150 200 250 300 400 575/600 V 100 125 150 150 200 300 400 450 General purpose continuous current (A) Reference Standard version contactors AC/DC coil voltage 3-pole[18] UL 2448 V[19] 48130 V[19] 210 LC1G115BEEA LC1G115EHEA 230 LC1G150BEEA LC1G150EHEA 250 LC1G185BEEA LC1G185EHEA 290 LC1G225BEEA LC1G225EHEA 340 LC1G265BEEA LC1G265EHEA 390 LC1G330BEEA LC1G330EHEA 490 LC1G400BEEA LC1G400EHEA 630 LC1G500BEEA LC1G500EHEA 250 300 600 700 850 -- LC1G630EHEA 300 350 700 800 900 -- LC1G800EHEA 200500 V LC1G115LSEA LC1G150LSEA LC1G185LSEA LC1G225LSEA LC1G265LSEA LC1G330LSEA LC1G400LSEA LC1G500LSEA LC1G630LSEA [19] LC1G800LSEA [19] TeSysTM Giga Contactors -- Advanced CONTACTORS 18 AND STARTERS-IEC [18] See MKTED210011EN for 4pole contactors and additional accessories. [19] Available 2Q 2022. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-15 Contactors and Overload Relays TeSysTM Giga Series 115-800 Amperes Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Giga Overload Relays TeSysTM Giga electronic overload relays provide wide protection flexibility in a limited number of references that cover up to 630 amperes. Alarm and status LEDs inform users in real time. Ground fault, phase imbalance, trip class (5E, 10E, 20E, 30E), and reset type can easily be configured on the device. Units can be directly mounted to the TeSys Giga contactors or can be individually wired. Table 18.31: TeSysTM Giga 3-Pole Overload Relays Relay setting range A Class 5...30 A 28...115 57...225 125...500 160...630 For direct mounting beneath contactor LC1G LC1G115...225 LC1G115...225 LC1G265...500 LC1G630 Reference LR9G115 LR9G225 LR9G500 LR9G630[20] LR9G225 TeSysTM Giga Reversing Contactors Components are available for customer assembly of TeSysTM Giga reversing contactors. For example, the following components must be ordered to build a reversing contactor, 200 hp at 460 V, with a 100250 V AC/DC coil. Table 18.32: Components Required for Building a Reversing Contactor Description Quantity Reference Contactors Lugs Terminal Mounting Auxiliary Contacts 2 1 2 (included) LC1G265KUEN DZ2FJ6 LA9G3612 Power Connections 1 Mechanical Interlock 1 LA9G3761 LA9G970 18 CONTACTORS AND STARTERS-IEC [20] Available 2Q 2022. 18-16 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM F Contactors and Overload Relays Refer to Catalog MKTED210011EN Contactors and Overload Relays TeSysTM F Non-Reversing Contactors Table 18.33: TeSys F Contactors--3 Pole Maximum Three-Phase Horsepower Ratings 200 V 230 V 460 V 575 V 350 400 900 -- -- 450 900 900 Maximum Current (A) Inductive Resistive AC-3 AC-1 1000 780 1000 1600 1400 1700 Continuous Current Rating (A) 1250 1350 1400 1700 Number of Poles 3 3 3 3 Catalog Number [21] [22] Panel Mount with Screws LC1F1000 LC1F780 LC1F1400 LC1F1700 Current Rated 2100 2100 3 LC1F2100 LC1700, F2100 Table 18.34: TeSys F Coil Voltage Codes [22] Contactor F780[23] Coil Suffix Code AC 50/60 Hz 120 V G7 Coil Part Number (Order Separately) AC 50/60 Hz 120 V LX1FX110 240 V LX1FX220 480 V LX1FX415 Coil Part Number (Order Separately) DC 24 V -- F1000 G7 LX1FK065[24] LX1FK127[24] LX1FK240[24] -- F1400F2100 G7 LX1FK070[24] LX1FK127[24] LX1FK240[24] -- CONTACTORS 18 AND STARTERS-IEC [21] Complete the catalog number by adding the coil voltage code from Table 18.34 TeSys F Coil Voltage Codes [21] For additional pole options and coil voltage options, see Catalog . Check with local sales office for availability. , page 18-17 (for example, LC1F265G7), or order the contactor (without a coil) and the coil separately. All coils except F780 include 1 N.O. holding circuit interlock contact. The F780 uses two coils that must be wired in series. [22] For additional pole options and coil voltage options, see Catalog MKTED210011EN. Check with local sales office for availability. [23] LC1F780 contactors operate with 2 coils as a set. The LX1FX· part number includes both coils. [24] Order 2 coils and connect them in series. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-17 Contactor Accessories LA1KN22 LA2KT2U E164862 CCN NLDX LR43364 Class 3211 04 TeSysTM K Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSysTM K Contactors Table 18.35: Instantaneous Auxiliary Contact Blocks[1] Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors Type of connection Screw clamp Auxiliary Contacts N.O. 2 -- 1 N.C. -- 2 1 4 -- 3 1 Catalog Number LA1KN20 LA1KN02 LA1KN11 LA1KN40 [2] LA1KN31 [2] 2 2 LA1KN22 [2] 1 3 LA1KN13 [2] -- 4 LA1KN04 [2] Table 18.36: Electronic Time Delay Auxiliary Contact Blocks Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors Voltage (V) Type Timing Range (S) Contacts Catalog Number 2448 Vac or Vdc On-delay 130 SPDT LA2KT2E 110240 Vac On-delay 130 SPDT LA2KT2U NOTE: Relay outputs, with single pole double throw, 240 Vac/Vdc, 2 A max. Maximum switching capacity 250 VA / 150 W Operating temperature: 10 to + 60°C (14 to 140°F) Reset time: 1.5 s during time delay, 0.5 after time delay Table 18.37: Suppressor Module with Incorporated LED Indicator Clip-on front mounting Voltage range 1224 Vac/Vdc 3248 Vac/Vdc 50129 Vac/Vdc 130250 Vac/Vdc 1224 Vdc 3248 Vdc 220250 Vac Type Varistor Varistor Varistor Varistor Diode + Zener Diode + Zener RC Sold in lots of 5 5 5 5 5 5 5 Catalog Number LA4KE1B [3] LA4KE1E [3] LA4KE1FC [3] LA4KE1UG [3] LA4KC1B [4] LA4KC1E [4] LA4KA1U [5] Table 18.38: Power Connectors Description Set of 6 power connections for reversing contactors with screw-clamp terminals Sold in lots of 100 Catalog Number LA9K0969 Table 18.39: Accessories for Overload Relays Description Terminal block for separate clip-on mounting of the overload relay onto 35 mm omega rail (AM1DP200) Type of Connection Screw-clamp Catalog Number LA7K0064 18 CONTACTORS AND STARTERS-IEC [1] For additional terminal options, see Catalog MKTED210011EN. Check with local sales office for availability. [2] Block of 4 contacts cannot be used with LP4K or LP5K contactors. [3] Protection by limitation of the transient voltage to 2 Uc maximum. Maximum reduction of the transient voltage peaks. Slight time delay on drop-out (1.11.5 times normal). [4] No overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.11.5 times normal). [5] Protection by limitation of the transient voltage to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out (1.2 times normal). 18-18 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Deca and F Contactors Refer to Catalog MKTED210011EN Contactor Accessories Front Mounted Auxiliary Blocks E164862 CCN NLDX LR43364 Class 3211 04 TeSysTM Deca and F Auxiliary Contacts, Time Delay, Mechanical Latch Table 18.40: Standard, Instantaneous Auxiliary Contact Blocks Snap-On Mounting To the front of LCDT20D258 (4P), LCD09D150 [6] or To the right side of LCF To the front of LCD80D150 or To the left side of LCF To the side of LCD09 to D150 only (not for use on TeSys F) Number of Contacts 4 [6] 2 1 2 Contact Arrangement N.O. N.C. 2 2 1 3 4 0 0 4 3 1 2 2 1 1 2 0 0 2 1 0 0 1 1 1 2 0 Catalog Number [6] LADN22 [7] LADN13 [7] LADN40 [7] LADN04 [7] LADN31 [7] LADC22 [7] [8] LADN11 [7] LADN20 [7] LADN02 [7] LADN10 [9] LADN01 [9] LAD8N11 [10] LAD8N20 [10] Table 18.41: Instantaneous Blocks with Dust-Tight Auxiliary Contacts (IP54) NEMA 12 Snap-On Mounting To the front of LPD40D80, LCDT20D258 (4P), LCD09 to D95 or To the right side of LCF Standard Contacts N.O. N.C. -- -- 2 -- 1 1 -- -- Dust-Tight Contacts N.O. N.C. 2 -- 2 -- 2 -- 2 -- Catalog Number LA1DX20 LA1DZ40 LA1DZ31 LA1DY20 [11] Table 18.42: Pneumatic Time Delay Contact Blocks Snap-On Mounting Time Delay Contacts N.O. N.C. Type To the front of LPD40D80, LCDT20D258 (4P), LCD09 to D150 or To the right side of LCF 1 1 On energization (on delay) On de- 1 1 energization (off-delay) Range of Time Delay 0.1 to 3 s [13] 0.1 to 30 s 10 to 180 s 1 to 30 s [14] 0.1 to 3 s [13] 0.1 to 30 s 10 to 180 s Catalog Number [12] LADT0 LADT2 LADT4 LADS2 LADR0 LADR2 LADR4 Table 18.43: Mechanical Latch Blocks with Manual or Electrical Unlatch (TeSysTM Deca only) Front snap-on mounting onto Application Catalog Number [15] LCD09 to D65A LC1D80 to D150, LP1D80 For silent operation and energy conservation For silent operation and energy conservation LAD6K10 [16][17] LA6DK20 [16] Table 18.44: Coil Voltage Codes for LAD6K/LA6DK Mechanical Latch Blocks Volts AC or DC 24 110/ 220/ 127 240 B F M TeSys Deca contactors: TeSysTM Deca Non-Reversing Contactors, page 18-11 and TeSysTM Deca Reversing Contactors, page 18-14 TeSys Deca overload relay accessories: page 18-28 TeSys Deca replacement coils: page 18-43 TeSys Deca dimensions: page 18-46 to page 18-58 CONTACTORS 18 AND STARTERS-IEC [6] For low consumption coils (LC1D09D38 only), only one front-mounted two-contact block allowed. No side-mounted contact blocks allowed. [7] For spring terminal versions of these blocks, add a 3 to the end of the catalog number (for example, LADN223). For slip-on versions, add 9 to the end of the catalog number (for example, LADN229). [8] Including 1 N.O. + 1 N.C. make-before break overlapping contacts. [9] This block cannot be added to the LC1D 09D38 contactors; a maximum of 2 blocks can be mounted on the LC1D40A-LC1/LP1D80 contactors only. [10] 1 block may be added to the left side of LC1D09D38, AC coils only; only 1 block may be added to either side of the LC1D40A-D80 contactors, AC coils only. Cannot be installed on TeSys Deca contactors with DC coils. [11] Device supplied with 4 ground terminal points. [12] For spring terminal versions of these blocks, add a 3 to the end of the catalog number (for example, LADT23). [13] Scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of the range. [14] Switching time between the opening of the N.C. contact and the closing of the N.O. contact: 40 ms ± 15 ms . [15] To complete the catalog number, add the coil voltage code from Table 18.44. For additional voltage options, see Catalog MKTED210011EN. Check with local sales office for availability. [16] Does not include internal coil clearing contact. [17] Low consumption DC contactors (and relays) (code coil L) are not compatible with the LAD6K10 mechanical latching blocks. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-19 Contactor Accessories LA9D3260 LA9D2561 LA9D80962 LA9D11567 LA9D511 TeSysTM Deca Accessories Refer to Catalog MKTED210011EN TeSysTM Deca Accessories[18] Table 18.45: For Power Pole or Control Connection Description Connectors for larger cable sizes EverlinkTM terminal block 3 poles 3 poles #4 AWG (25 mm2) Links for the parallel connection of: 3 poles (wye-delta shorting strap) Control circuit take-off from main pole For use with contactors LC1/LP1 D09D38 D40AD65A D09D38 D40AD65A D80, D95 F115 F150, F185 F225, F265, F330, F400 F500 D80, D95 D115, D150 Replacement power terminal block D115, D150 Plunger (fire pump accessory) D09150 Sold in lots of 1 1 10 1 1 1 1 1 1 10 10 1 -- Table 18.46: For Marking Description Reference label holder Snap-on, 8 x 22 mm Snap-on, 8 x 18 mm, 3 poles Sheet of 300 labels self adhesive, 7 x 21 mm For use with contactors LC1/LP1 4-pole contactors D80D115 D09D65A, DT20 DT80A, LADN, LADT, LADR For holder LA9D92 Sold in lots of 100 100 1 Table 18.47: For Mounting Description Set of shims for mounting LAD8N and LA8DN Retrofit plate for replacing LC1D40D65 with LC1D40AD65A 35 mm DIN Rail -- 2 m For use with contactors LC1/LP1 D80D95 D40AD65A LC1D09D80 Sold in lots of 1 1 10 Table 18.48: Replacement Contacts Three-pole Four-pole For use with contactors LC1D115 LC1D150 LC1D115 3 poles 3 poles 4 poles Table 18.49: Arc Chambers Three-pole Four-pole For use with contactors LC1D115 LC1D150 LC1D115 3 poles 3 poles 4 poles TeSys Deca contactors: page 18-11 and page 18-14 TeSys Deca overload relay accessories: page 18-28 TeSys Deca contactor accessories: page 18-19 TeSys Deca replacement coils: page 18-43 TeSys Deca dimensions: page 18-46 to page 18-58 TeSys F contactors: page 18-17 and page TeSys F replacement coils and parts: page 18-44, page , and page www.se.com/us Catalog Number LA9D3260 LAD96560 LAD9P3 LAD9P33 LA9D80962 LA9FF601 LA9FG601 LA9FH601 LA9FK601 LA9D8067 LA9D11567 LA9D115603 LAD9FP3 Catalog Number LA9D92 LAD90 LA9D93 Catalog Number LA9D511 LAD7X3 AM1DP200 Catalog Number LA5D1158031 LA5D150803 LA5D115804 Catalog Number LA5D11550 LA5D15050 LA5D115450 18 CONTACTORS AND STARTERS-IEC [18] For additional accessory and replacement part options, see Catalog MKTED210011EN. Check with local sales office for availability. 18-20 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Deca Contactors Refer to Catalog MKTED210011EN Contactor Accessories LA4DA1U LA4DC3U RC and Varistor Coil Suppressors RC Coil Suppressor · Limitation of transient voltage to 300% of nominal voltage maximum. · Oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.22 times normal). Table 18.50: Resistor/Capacitor Circuit (RC) for Reduction of Electrical Noise in AC Contactor Coils Installed by Snapping into the cavity on the right side without tools [19] Snap-on mounting, and connection without tools to the contactor coil terminals Mounting on LCD09D38 (3P), LC1DT20DT40 (4P) LC1D40A65A (3P), LC1DT60ADT80A (4P) Operating Voltage 50/60 Hz 2428 Vac 50127 Vac 110240 Vac 24-48 Vac 50127 Vac 110240 Vac 380415 Vac Catalog Number LAD4RCE LAD4RCG LAD4RCU LAD4RC3E LAD4RC3G LAD4RC3U LAD4RC3N Screw connection to the contactor coil terminals LCD80D150 (3P), LC1D80D115 (4P) 2448 Vac 50127 Vac 110240 Vac 380415 Vac LA4DA2E LA4DA2G LA4DA2U LA4DA2N Varistor Coil Suppressor[20] · Limitation of transient voltage value to 200% of nominal voltage maximum. · Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 1.5 times normal). Table 18.51: Varistor (Peak Limiting) for Reduction of Electrical Noise in AC Contactor Coils Installed by Snapping into the cavity on the right side without tools [19] Snap-on mounting, and connection without tools to the contactor coil terminals Mounting on LCD09D38 (3P), LC1DT20DT40 (4P) LC1D40AD65A (3P), LC1DT60ADT80A (4P) Operating Voltage 2448 Vac 110250 Vac 2448 Vac/Vdc 110250 Vac/Vdc Catalog Number LAD4VE LAD4VU LAD4V3E LAD4V3U Screw connection to the contactor coil terminals Screw connection to the contactor coil terminals LCD80D115 (3P) LC1D80D115 (4P) LCD80D95 (3P) LC1D80 (4P) 2448 Vac 110250 Vac 2448 Vdc 110250 Vdc LA4DE2E LA4DE2U LA4DE3E LA4DE3U Diode Coil Suppressor · No overvoltage or oscillating frequency. · Polarized component. Increased drop-out time (610 times normal). Table 18.52: Diode for Reduction of Electrical Noise in DC Contactor Coils Installed on the upper part by Mounting on Operating Voltage, DC Catalog Number Snap-on mounting and connection w/o LCD09 to D38 (3P), tools to the contactor coil terminals LC1DT20 to DT40 (4P) 24250 Vdc LAD4DDL Clip-on front mounting LCD40A to D65A (3P), LC1DT60A to DT80A (4P) 24250 Vdc LAD4D3U Screw connection of wire to the contactor coil terminals LCD80 to D95 (3P), LC1D80 (4P) 24250 Vdc LA4DC3U CONTACTORS 18 AND STARTERS-IEC [19] Installing the suppressor into the cavity makes the electrical connection. Overall width of the contactor remains the same. [20] For additional accessory and replacement part options, see Catalog MKTED210011EN. Check with local sales office for availability. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-21 Contactor Accessories LAD4T3B LAD4BB LA4DFB LAD9ET1S LADN22S LU9ET1S TeSysTM Deca Contactors Refer to Catalog MKTED210011EN Bidirectional Diode Coil Suppressor · Protection provided by limiting the transient voltage to 2 Uc max. · Maximum reduction of transient voltage peaks Table 18.53: Bidirectional Peak Limiting Diode[21] Installed by Snapping into the cavity on the right side of the contactor [22] Clip-on front mounting and connection without tools to the contactor coil terminals [23] Screw mounting [24] Mounting on LCD09D38 (3P) [23] LC1DT20DT40 (4P) LCD40AD65A (3P), LC1DT60A DT80A (4P) LCD80D95 (3P), LC1D80 (4P) Operating Voltage Vac (50/60 Hz) Vdc 24 -- -- 24 1224 1224 -- 24 www.se.com/us Catalog Number LAD4TB LAD4TBDL LAD4T3B LA4DB3B Table 18.54: Cabling Accessories[21] Usage Mounting on For adapting existing wiring to a new product or for use with top-mounting accessory. LC1D09D38 For adapting existing wiring to a new product or for use with top-mounting accessory LC1D40AD65A Operating Voltage 50/60 Hz Without coil suppression With coil 2448 Vac suppression (varistor) 50127 Vac Without coil suppression Catalog Number LAD4BB LAD4BBVE LAD4BBVG LAD4BB3 TeSys Deca contactors: TeSysTM Deca Non-Reversing Contactors, page 18-11TeSysTM Deca Reversing Contactors, page 18-14 and TeSys Deca contactor accessories: page 18-19 TeSys Deca overload relay accessories: page 18-28 TeSys Deca replacement coils: page 18-43 TeSys Deca dimensions: page 18-46 to page 18-58 TeSysTM Deca Electronic Timers and Interface Modules The following accessories require use of cabling accessories (LAD4BB) for proper mounting. See page 18-22 for illustration. Table 18.55: Electronic Serial Timer Modules Type Operational Voltage [25] 24250 Vac 100250 Vac On-delay LC1D09D65A LC1D80D150 Time Delay 0.12 s 1.530 s 25500 s Catalog Number LA4DT0U LA4DT2U LA4DT4U Table 18.56: Interface Modules[21] Interface Type [26] Relay Solid State Operational Voltage 24250 Vac 100250 Vac LC1D09D150 -- LC1D09D65A LC1D80D115 Input Voltage 24 Vdc 24 Vdc Catalog Number LA4DFB LA4DWB Table 18.57: TeSysTM Safety-Chain Identification System Description Red retrofit contactor safety cover Red auxiliary contact block, 2 N.O. + 2 N.C. Red retrofit safety sticker Compatibility LC1D09D65A, CAD32, CAD50 LC1D80 LC1D115D150 LC1D09D150, CAD32, CAD50 TeSysTM Ultra Package Qty 10 1 1 1 10 Catalog Number LAD9ET1S LAD9ET3S LAD9ET4S LADN22S LU9ET1S 18 CONTACTORS AND STARTERS-IEC [21] For additional voltage and accessory options, see Catalog MKTED210011EN. Check with local sales office for availability. [22] Installing the suppressor into the cavity makes the electrical connection. Overall width of the contactor remains the same. [23] For LC·D09LC·D65A with DC or low consumption DC coils, 3pole contactors are fitted wit built-in bidirectional diode suppression as standard. [24] Mounting at the top of the contactor on coil terminals A1 and A2. [25] For 24 V operation, the contactor must be fitted with a 21 V coil: coil voltage code Z5 for 50 Hz; Z6 for 60 Hz; and ZD for DC. [26] Adapter required for D09D65A, see . 18-22 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Deca Contactors Refer to Catalog MKTED210011EN Contactor Accessories TeSysTM Deca Reversing Contactors Table 18.58: Components and Kits for Reversing Assemblies[27] Kits for Assembly of Reversing Contactors Description For contactor (2 identical contactors) LC1 D09 to D38 Part Number LAD9R1V Kit comprising of: · Mechanical interlock · Electrical wiring links · Power wiring links LC1 DT20 to DT40 LADT9R1V LAD 9R1 LA9 D8069 Components for Assembly of Reversing Contactors Kit comprising of: · Mechanical interlock · Power wiring links LC1 D09 to D38 LC1 D40A to D65A LAD9R1 LAD9R3 For Contactor (2 Identical Contactors) Mechanical Interlock Mechanical Interlock with Integral Electrical Interlocking Reversing Power Links (Parallel and Reverser) LC1 D40A to D65A LC1 D80 to D95 (AC coil) LC1 D80 to D95 (DC coil) LC1 D115 to LC1D 150 LAD4CM LA9D50978 LA9D80978 -- -- LA9D4002 LA9D8002 LA9D11502 LA9D65A69 LA9D8069 LA9D8069 LA9D11569 TeSys Deca contactors: TeSysTM Deca Non-Reversing Contactors, page 18-11 and TeSysTM Deca Reversing Contactors, page 18-14 TeSys Deca contactor accessories: page 18-19 TeSys Deca replacement coils: page 18-43 TeSys Deca dimensions: page 18-46 to page 18-58 CONTACTORS 18 AND STARTERS-IEC [27] For additional reversing accessory options, see Catalog MKTED210011EN. Check with local sales office for availability. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-23 Contactor Accessories TeSysTM Giga Contactors Refer to Catalog MKTED210011EN Lugs and Mounting Table 18.59: Lugs and Mounting for TeSysTM Giga Contactors and Overload Relays[28] www.se.com/us Reference Rating Wire range For use with LC1 For use with LR9 Box lug spreader bar (required) DZ2FG1 (includes 1 lug, (6 required)) 200 6 to 3/0 AWG G115, G225 G115, G225 LA9G3711 DZ2FH1 (includes 1 lug, (6 required)) 275 6 to 300 MCM G115, G225 G115, G225 LA9G3711 DZ2FJ1 (includes 1 lug, (6 required)) 500 4 to 500 MCM G115, G225, G265, G330, G400, G500 G115, G225, G500 LA9G3711, LA9G3712 DZ2FK1 (includes 1 lug, (6 required)) 630 2 to 600 MCM G265, G330, G400, G500 G630, G800 G500 G630 LA9G3712 LA9G3714 DZ2FL1 (includes 1 lug, (6 required)) 800 2 to 600 MCM G630, G800 G630 LA9G3714 18 CONTACTORS AND STARTERS-IEC Reference Rating (A) Wire range For use with LC1 For use with LR9 Box lug spreader bar (required) LA9G3601 Straight Bar AL400L61K3 (includes 3 lugs) 400 2 to 500 MCM (AL) 2 to 600 MCM (CU) G115, G225 G265, G330 G400, G500 G115, G225 G500 LA9G3711 LA9G3712 LA9G3611 Spreader Bar AL600LS52K3 (includes 3 lugs) 400/600 2/0 to 500 MCM (AL or CU) G265, G330 G400, G500 G500 LA9G3712 Al800M23K (includes 3 lugs) 800 3/0 to 500 MCM (AL or CU) G630, G800 G630 LA9G3714 Al800P6K (includes 3 lugs) 800 3/0 to 600 MCM (AL or CU) G630, G800 G630 LA9G3714 LA9G3111 Flexible Terminal Extensions Flexible connecting bars to connect TeSys Giga High power contactors with MCCBs mounted in the same plane and orientation. These bars can be used along with Advanced or Standard version contactors. They help to get a quick and easy connection between contactor and MCCB with saving in installation time. Table 18.60: Flexible Terminal Extensions for MCCBs Description Compatible with Contactors To connect with PowerPacTTM MCCB Flexible terminal extensions 3pole LC1G115...LC1G225 LC1G265...LC1G500 LC1G630...LC1G800 H-J Frame 3P, GV5PB L Frame 3P, GV6PB P Frame 3P Quantity Set of 3 3 3 Reference LA9G3111 LA9G3112 LA9G3113 [28] See MKTED210011EN for additional accessories. 18-24 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Giga Contactors Refer to Catalog MKTED210011EN Contactor Accessories LAG8N113 Auxiliary Contact Modules Auxiliary contacts give an indication of the contactor status. They can be used for remote visual signaling, alarming, electrical locking, relay activation, and others. Each contactor is equipped with 1 NO (normally open) and 1 NC (normally closed) auxiliary contact block as standard. Mechanically linked mirror contacts The NC (normally closed) contact of the auxiliary contact block is a mirror contact in conformity to IEC 6094751. It is mechanically linked to reliably represent the state of the main power contacts and wherever auxiliary contact state reliability is essential. The NC contact of the auxiliary contact cannot be closed at the same time as a normally open power contact. Contact module compatibility TeSysTM Giga auxiliary contact module is compatible with a range of TeSys Giga contactors. Each TeSys Giga contactor can be equipped with up to four auxiliary contact modules. Table 18.61: Electrical Characteristics Characteristics Rated thermal current (A) Minimum load Contact reliability 10 1 mA at 17 V DC Failure rate <10 Type of connections: · Push-In Table 18.62: Auxiliary Contact Modules Description Terminal type Types of contacts Auxiliary contact module Push-In 1 NO + 1 NC 2 NO Sold in lots of 1 1 Reference LAG8N113P[29] LAG8N203P Connection Kits and Mechanical Interlock Table 18.63: Star-Delta (Wye Delta) Connection Kits Description Connection kit: bars for Line/Delta Star contactor assembly Suitable for: 3-pole 3-pole (with cable memory kit) For Line/Delta contactor LC1G115/LC1G225 LC1G265/LC1G500 LC1G265/LC1G500 LC1G630/LC1G800 LC1G630/LC1G800 LC1G265/LC1G500 LC1G630/LC1G800 + Star contactor LC1G115/LC1G225 LC1G115/LC1G225 LC1G265/LC1G500 LC1G265/LC1G500 LC1G630/LC1G800 LC1G115/LC1G225 LC1G265/LC1G500 Reference LA9GQQ330 LA9GSQ330 LA9GSS330 LA9GTS330 LA9GTT330 LA9GSQ331 LA9GTS331 NOTE: RE17RMMWS timer to be used for Star-Delta starter application. Table 18.64: Reverser Connection Kits Description Suitable for: Connection kit: bars for reverser contactor assembly 3-pole Table 18.65: Changeover Connection Kits Description Suitable for: Connection kit: bars for changeover contactor assembly 3-pole 4-pole Compatible with contactors LC1G115/LC1G225 LC1G265/LC1G500 LC1G630/LC1G800 Compatible with contactors LC1G115/LC1G225 LC1G265/LC1G500 LC1G630/LC1G800 LC1G115/LC1G225 LC1G265/LC1G500 LC1G630/LC1G800 Reference LA9G3760 LA9G3761 LA9G3762 Reference LA9G3750 LA9G3751 LA9G3752 LA9G4750 LA9G4751 LA9G4752 CONTACTORS 18 AND STARTERS-IEC [29] Always supplied with TeSysTM Giga LC1G contactors (fitted to the right side lateral face). © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-25 Contactor Accessories LA9GRFB1 LA9GRFB2 LA9DRD10 TeSysTM Giga Contactors Refer to Catalog MKTED210011EN Table 18.66: Mechanical Interlock[30] Description Mechanical interlock between contactors[31] Identical contactor frames LC1G265 to 500 and LC1G182 to 225 LC1G630 to 800 and LC1G265 to 500 www.se.com/us Reference LA9G970 LA9G971 LA9G972 Retrofit Bases · Suitable for 3pole contactors · Retrofit bases to replace similar ratings of TeSysTM F contactors with TeSysTM Giga contactors · Enables quick and simple replacement in the existing installation · Two references to cover ranges from LC1F115 to F500 TeSysTM Giga retrofit bases are designed for integrating new TeSysTM Giga contactors into installations using TeSys FTM contactors. The retrofit bases help reduce replacement and reinstallation time when you upgrade your system with the new range of contactors. The retrofit bases come in two frame sizes. Table 18.67: Retrofit Bases Description Accessory used to replace TeSysTM LC1F115225 replaced by LC1G115225 LC1F265500 replaced by LC1G265500 LC1F630800 replaced by LC1G630800 Reference LA9GRFB1 LA9GRFB2 LA9GRFB3[32] Remote Wear Diagnostic (RWD) Module Table 18.68: Remote Wear Diagnostic (RWD) Module Description Remote wear diagnostic module for TeSysTM Giga contactor - 1 NO Remote wear diagnostic module for TeSysTM Giga contactor - 1 NC Reference LA9GRD10[33] LA9GRD01 18 CONTACTORS AND STARTERS-IEC [30] UL pending. [31] Always supplied with TeSysTM Giga LC!G contactor, fitted to the right side lateral face. [32] Available 2Q 2022. [33] Remote wear diagnostic (RWD) module can be installed and used only in the Advanced contactor version. 18-26 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM F Contactors Refer to Catalog MKTED210011EN Contactor Accessories TeSysTM F Contactors Table 18.69: Lugs for TeSys F Contactors Contactor Type LC1 F780 Cable Size AWG Range Lug Kit[34] (Quantity of 6) 4 x 1/0 to 750 MCM DZ2FX6 TeSys F overload relay accessories: page Individual Lug (Quantity of 1) -- TeSys F replacement coils and parts: page 18-44, page , and page TeSys F dimensions: page 18-49, page 18-61 CONTACTORS 18 AND STARTERS-IEC [34] For additional options and accessories, see MKTED210011EN. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-27 Overload Relay Accessories LA7D901 LA7D03 TeSysTM Deca Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys Deca Overload Relay Accessories Table 18.70: Mounting Kits and Plates[1] Description Separate mounting kits for mounting to 35 mm DIN rail or for panel mounting with screws For use with overload relays: LRD0135 and LR3D0135 LRD0135 and LRD0135 for ring tongue terminals LRD04L-32L, LR3D04L32L, and LR9D0132 LRD3, LR3D3, LR2D35 Cat. No. LAD7B10 LAD7B106 LAD7B205 LAD96560 Table 18.71: Accessories Description For use with Prewiring kit allows direct connection of the N.C. contact of relay LRD01D32 or LR3D01D32 to the contactor Remote stop/tripping or electrical reset [2] Reset by flexible cable 500 mm (19.6 in.) LC1D09 to D18 LC1D25 to D38 All relays except LRD01D32 LRD01-D32, LRD3, LR3D3 Table 18.72: Control Circuit Voltages for LA7D03 and LAD703 Volts 24 AC 50/60 Hz B DC B Standard Package 10 10 Catalog Number LAD7C1 LAD7C2 1 LAD703 [3] 1 LAD7305 110 F F 18 CONTACTORS AND STARTERS-IEC [1] When using mounting plates, separate mounting kits are also required. [2] The time that the LA7D03 can remain energized depends on its rest time; 1s pulse duration with 29s rest time; 3s pulse duration with 90s rest time; maximum pulse duration of 5s with rest time of 300s. [3] Part number to be completed by adding coil voltage code, (for example, LAD703F). 18-28 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Giga Overload Relay Refer to Catalog MKTED210011EN Overload Relay Accessories TeSysTM Giga Overload Relay Accessories Table 18.73: Remote Reset Control Device Description Sold in lots of: Remote Reset control function 1 by flexible cable (length = 0.5m) Reference LAD7305 LAD7305 CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-29 18 CONTACTORS AND STARTERS-IEC Motor Starters and Protectors TeSysTM Ultra Combination Motor Controllers Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Ultra Motor Starter The TeSys Ultra motor starter is integrated, making it simple to choose and install. It consists of a control unit snapped in a power base. TeSys Ultra can be configured to fit specific applications as well. Optional accessories include a reverser, a current limiter, predictive maintenance options, and communication options. For detailed information about TeSys Ultra, visit our website. Power Base LUB12 Power Base LUB120 Control Unit 1 Power Base 2 Control Unit + + = 3 Optional Accessories (Type E Line Spacer, Function Modules, TeSys Ultra Motor Starter Auxiliary Contacts etc.) Selecting TeSysTM Ultra Motor Starters in Three Steps Table 18.74: Step 1. Select Power Base (Only two different bases up to 32 A) Control Connection With non-removable screw terminations Without screw terminations Max. Current (A) 12 32 12 32 200 V 3 10 3 10 Maximum Horsepower Ratings Three-Phase Single-Phase 230 V 460 V 575 V 115 V 230 V 3 7.5 10 0.5 2 10 20 25 2 5 3 7.5 10 0.5 2 10 20 25 2 5 Self-Protected Starter Base Catalog Number LUB12 LUB32 LUB120 [1] LUB320 [1] Table 18.75: Step 2. Select Control Unit [2] Setting Range (A) Standard 3-phase Class 10 trip [3] Advanced 3-phase Class 10 trip [3] 0.150.6 0.31.4 1.255.0 312 4.518 832 LUCAX6 LUCA1X LUCA05 LUCA12 LUCA18 LUCA32 LUCBX6 LUCB1X LUCB05 LUCB12 LUCB18 LUCB32 Advanced single-phase Class 10 trip [3] LUCCX6 LUCC1X LUCC05 LUCC12 LUCC18 LUCC32 Advanced 3-phase Class 20 trip [3] LUCDX6 LUCD1X LUCD05 LUCD12 LUCD18 LUCD32 Table 18.76: Voltage Codes Volts DC AC DC or AC 24 BL [4] B -- 110240 -- -- FU Table 18.77: Step 3. Select Auxiliary Contacts (optional) Auxiliary Contact Terminals Contact Indicates Contact Normal Status Auxiliary Contact Blocks Screw Ready condition Fault condition N.O. N.C. Screw Ready condition Fault condition N.O. N.O. Auxiliary Contact Function Modules Screw Pole state 2 N.O. Screw Pole state 1 N.O. and 1 N.C. Screw Pole state 2 N.C. Off O I O O O OI 1 Ready I I I O O OI I Contact State for Each Mode [5] Run Short Overload Trip Circuit Trip (Manual Reset) Overload Trip (Remote/Auto Reset) [6] Catalog Number I I I O I IO O O O O I O O I I O O O I O O I I I LUA1C11 I I LUA1C20 O LUFN20 LUFN11 LUFN02 Table 18.78: Accessories Accessory Current limiter Reverser Line phase barrier Multifunction control unit Function modules Communication modules Soft starter + TeSys Ultra Powerbus Configuration and connection accessories Quick Description Increases the breaking capacity to 130 kA @ 460 V and to 65 kA @ 575 V Stacked or side mounted (LU6MB0 only) Required for use as a self-protected combination starter (UL 508 Type E) Has functions for monitoring and predictive maintenance Fault differentiation, thermal overload, motor load indication Integrates into existing networks, major portocols are available Use Altistart U01soft starter with TeSys Ultra Use TeSys Ultra with a prewired system SoMove software, bus bar, external handle For details & selection, see: page 18-32 page 18-32 page 18-32 page 18-32 page 18-32 page 18-33 page 18-42 page 18-33 page 18-33 E164862 CCN NLDX LR43364 Class 3211 04 Accessories: Power Base and Plug-in Accessories, page 18-31 to page 18-33 Dimensions: TeSysTM Ultra Starter Dimensions, page 18-64 Overload Relays: page 18-9 Accessories: page 18-18 Dimensions: page 18-63 [1] For use with reversing modules or communication modules with prewired connector. [2] The control unit contains solid-state overload relay and control power source for TeSys Ultra. For more details on the different control units, their functions, and placement on the power base, see Power Base and Plug-in Accessories, page 18-31. [3] Complete the catalog number by adding appropriate code from Table 18.76 (for example, LUCAX6FU). [4] DC voltage with range of 0.90 to 1.10 of nominal. [5] I indicates closed contact; O indicates open contact. [6] Requires multifunction or advanced control unit plus fault differentiation module LUFDA10. 18-30 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Ultra Combination Motor Controllers Refer to Catalog MKTED210011EN Table 18.79: Control Units and Functions Control Units and Functions Motor Starters and Protectors Reference Protection type Class 10 Class 20 Class 530 Single Phase: LUCC Class 10 only Protection functions Short circuit Over current Thermal overload Phase loss Phase imbalance Ground fault Underload, long start, jam Control functions Manual reset Automatic or local/remote reset Fault differentiation Thermal alarm Motor load display Fault history Alarm threshold adjustment Tripping test Standard LUCA LUCB Advanced LUCC LUCD Multifunction LUCM = built-in the control unit = works with the related function modules (see page 18-32) Power Base and Plug-in Accessories See below where to install accessories on the power base. Only one accessory can be installed in each location. 2 Control Unit i Multifunction Control 3 Auxiliary Function or Communication Module Auxiliary Contact Block c Line Phase Barrier p Reverser Unit mounts under power base r Current Limiter attaches above power base i Multifunction Control Unit Control Circuit Contact Block 1 CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-31 Motor Starters and Protectors Line Phase Barrier Reverser Unit Assembled under the Power Base Alarm Differentiation TeSysTM Ultra Combination Motor Controllers Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Reversing Starters Table 18.80: Power Base with Reversing Unit assembled under the base Control Connection With screw terminations Max. Current (A) 12 32 200 V 3 10 Maximum Horsepower Ratings Three-Phase Single-Phase 230 V 460 V 575 V 115 V 230 V 3 7.5 10 1.5 2 10 20 25 2 5 Self-Protected Starter Base Catalog Number LU2B12[7] LU2B32[7] Table 18.81: Select Control Unit Options[8][9] Setting Range (A) 0.150.6 0.31.4 1.255.0 312 4.518 832 Standard Three-Phase Class 10 trip [10] LUCAX6 LUCA1X LUCA05 LUCA12 LUCA18 LUCA32 Advanced Three-Phase Class 10 trip [10] LUCBX6 LUCB1X LUCB05 LUCB12 LUCB18 LUCB32 Advanced Single-Phase Class 10 trip [10] LUCCX6 LUCC1X LUCC05 LUCC12 LUCC18 LUCC32 Advanced Three-Phase Class 20 trip [10] LUCDX6 LUCD1X LUCD05 LUCD12 LUCD18 LUCD32 Table 18.82: Voltage Codes Volts DC AC DC or AC 24 BL [11][12] B -- 110240 -- -- FU Table 18.83: Reversing Modules for Field Addition Mounting Beneath Beside Catalog No. LU2MB0 LU6MB0 Wiring Adapter LU9MR1C LU9MR1 Note: For LU2MB0 and LU6MB0, voltage code required; must match control unit. TeSysTM Ultra Accessories Table 18.84: Current Limiter [13][14] Accessory Application Current limiter/isolator Additional current limiting aspects for the starter Limiter cartridge Replacement cartridge for LUALB1 Technical Data 130 kA at 460 V 65 kA at 575 V 130 kA at 460 V 65 kA at 575 V Mounting Direct mounting to LUB and LU2B -- Cat. No. LUALB1 LUALF1 Table 18.85: Function Modules [13][15] Module Fault differentiation: with manual reset (thermal overload) with auto reset Thermal overload pre-alarm Motor load indication Parallel wiring Description For use with: Provides indication between an Advanced control overload trip and a short circuit trip. units only Signals when the motor current reaches 1.05 of the full load setting on the control unit. Provides a signal proportional to the average currents in the three phases divided by the full load current setting of the control unit. The output corresponds to a load status of 02 times the full load setting of the control unit. Provides a convenient way to reduce control wiring and allow for connecting starters to a communications network by providing 24 Vdc for the starters. Advanced control units only Advanced or multifunction control units Advanced or multifunction control units (24 Vdc only) and LU9BN11C or LU9MRC prewired connector Operation Requirements 24250 Vac/Vdc (power from control unit) 24250 Vac/Vdc (power from control unit) 420 mA (requires separate 24 Vdc power supply) LU9G02 splitter box and PLC network Catalog Number LUFDA10 LUFW10 LUFV2 LUFC00 Parallel Wiring Motor Load Indicator 18 CONTACTORS AND STARTERS-IEC [7] Voltage code required. [8] The control unit contains solid-state overload relay and control power source for TeSys Ultra. For more details on the different control units, their functions, and placement on the power base see Control Units and Functions, page 18-31. [9] Control units for 4.518 and 832 can be used only with 32 A rated power bases (LUB32, LUB320, and LU2B32). [10] Complete the catalog number by adding the appropriate code from (for example LUCAX6FU). [11] DC voltage with range of 0.90 to 1.10 of nominal. [12] Voltage code to use for a power base with a communication module. [13] See page 18-31 for placement on the power base. [14] Increases the breaking capacity of the motor starter. [15] Offers customization for specific application requirements. 18-32 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Ultra Combination Motor Controllers Refer to Catalog MKTED210011EN Motor Starters and Protectors Accessories Table 18.86: Communication Modules [16][17] Communication modules allow the TeSys Ultra starter to be connected directly to the network. They are for use with advanced or multi-function control units (24 Vdc only) and require a separate 24 Vdc power supply. Module ModbusTM Communication CANopen Communication Profibus Communication DeviceNetTM Communication Prewired Connector LU9BN11C or LU9MRC LU9BN11L or LU9MRL LU9BN11L or LU9MRL LU9BN11L or LU9MRL Catalog Number LULC033 LULC08 LULC07 LULC09 Modbus Profibus DeviceNet CANopen Table 18.87: TeSysTM Ultra Cabling Accessories--Power Bus Bars Description 3-Pole, 63 A Bus Bar Terminal blocks Application For feeding 2 TeSys Ultra controllers For feeding 3 TeSys Ultra controllers For feeding 4 TeSys Ultra controllers For feeding 5 TeSys Ultra controllers Top feed for use with bus bars Pitch 45 54 72 45 54 45 54 72 54 -- Standard Pack 1 1 1 1 1 1 1 1 1 1 Catalog Number GV2G245 GV2G254 GV2G272 GV2G345 GV2G354 GV2G445 GV2G454 GV2G472 GV2G554 GV1G09 Table 18.88: Control Circuit Accessories [18] for placement on power base. Accessory Control circuit contact block Through-the-door operating mechanism (without trip indication) Control circuit filters Application Technical Data Switches control circuit power via LUB 5 A at 600 Vac handle (NEC430-74 compliance) 5 A at 250 Vdc Use to enclose TeSys LUB only. NEMA 1, 12, 3R, 4, 4X Red/Yellow Use with electronic or triac output controllers Up to 150 Vac max. Pre-wired connector Central control when using communication modules See Table 18.86 for usage. Mounting Side mounting to LUB and LU2B only Kit Directly to coil terminals Lower power terminals to communication module. Non-reversing Reversing Non-reversing Reversing Catalog Number LUA8E20 LU9APN44 LUA4F11 LUA4F12 LU9BN11C LU9BN11L LU9MRL CONTACTORS 18 AND STARTERS-IEC [16] See page 18-31 for placement on the power base. [17] Communication capabilities can be integrated into existing automation architecture via a variety of protocols. [18] See Power Base and Plug-in Accessories, page 18-31 © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-33 Motor Starters and Protectors TeSysTM Deca Manual Motor Controllers Refer to Catalog MKTED210011EN www.se.com/us GV2P GV4PB TeSysTM Power Motor Circuit Breakers The TeSysTM Power Motor Circuit Breakers family of products provide efficient motor control and protection solutions up to 520 amps. There are a variety of UL approved applications that enable specified configurations for use as a manual starter, motor disconnect, independent branch short-circuit protection, motor overload protection, or for use with a motor controller such as a contactor to build a complete motor control circuit. Certain configurations are approved for group motor applications as well. Refer to the following selection tables for application information, as well as the Motor Control Solutions for the North American Market data bulletin (8536DB0901) for additional information. The GV2P (up to 32 amps) and GV3P (up to 65 amps) is rated to UL 60947-4-1 as a motor starter, and also possess Type E ratings for manual switching applications. These devices can be combined with a specified TeSys Deca contactor as a Type F combination motor controller (with specified line side spacer/accessories), with SCCR up to 100kA. The GV2ME (up to 32 amps) combined with a specified TeSys Deca contactor is ideal for group motor applications. The TeSys island load management starters are approved for use with TeSys GV2P and GV3P devices as a group motor arrangement. See selection table for application specifics. The GV4PB, GV5PB, and GV6PB are motor protective circuit breakers rated to UL 489, are approved as branch circuit protection (no line side spacer required) and include motor overload protection. A full motor branch circuit is completed with the addition of a contactor, providing a compact two-component solution up to 520 motor full load amps. Pre-trip alarm accessories can be applied to these units to help anticipate and resolve issues, minimizing operator or maintenance interaction. Table 18.89: GV2, GV3 Manual Motor Protectors (UL 60947-4-1) Thermal Setting (A) 115 V Single-Phase 200 V Maximum Horsepower Ratings Three-Phase 230 V 115 V 200 V 230 V GV2P GV2ME 0.100.16 -- -- -- -- -- -- 0.160.25 -- -- -- -- -- -- 0.250.40 -- -- -- -- -- -- 0.400.63 -- -- -- -- -- -- 0.631 -- -- -- -- -- -- 11.6 -- -- 1/10 -- -- -- 1.62.5 -- 1/6 1/6 -- 1/2 1/2 2.54 1/8 1/4 1/3 -- 3/4 3/4 46.3 1/4 1/2 1/2 3/4 1 1.5 610 1/2 1 1.5 1 2 3 914 3/4 2 2 2 3 3 1318 1 2 3 2 5 5 1723 1.5 3 3 3 5 7.5 2025 2 -- -- -- 7.5 7.5 2432 2 5 5 5 7.5 10 913 1/2 -- 1.5 -- 3 3 1218 3/4 -- 2 -- 3 5 1725 1.5 -- 3 -- 5 7.5 2332 2 -- 3 -- 7.5 7.5 3040 3 -- 5 -- 10 10 3750 3 -- 7.5 -- 10 10 4865 3 -- 10 -- 15 15 460 V -- -- -- -- -- 3/4 1 2 3 5 10 10 15 15 20 7.5 7.5 15 20 25 30 40 575 V -- -- -- -- 1/2 3/4 1.5 3 5 7.5 10 15 20 20 25 10 10 20 25 30 40 50 GV2ME push button[19] Catalog Number GV2ME01 GV2ME02 GV2ME03 GV2ME04 GV2ME05 GV2ME06 GV2ME07 GV2ME08 GV2ME10 GV2ME14 GV2ME16 GV2ME20 GV2ME21 GV2ME22 GV2ME32 -- -- -- -- -- -- -- GV2/3P rotary handle Catalog Number GV2P01 GV2P02 GV2P03 GV2P04 GV2P05 GV2P06 GV2P07 GV2P08 GV2P10 GV2P14 GV2P16 GV2P20 GV2P21 GV2P22 GV2P32 GV3P13 GV3P18 GV3P25 GV3P32 GV3P40 GV3P50 GV3P65 18 CONTACTORS AND STARTERS-IEC [19] For spring terminals add 3 to the catalog number (for example, GV2ME013). GV2ME013) is not available with spring terminals. For ring terminals, add 6. 18-34 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Deca GV Manual Starters and Protectors Refer to Catalog MKTED210011EN and 8536CT1901 Motor Starters and Protectors GV4PB Table 18.90: GV4, GV5, GV6 UL 489 Motor Protective Circuit Breakers Motor FLA Dial Range 0.8 ... 2 1.4 ... 3.5 2.9 ... 7 5 ... 12.5 10 ... 25 20 ... 50 40 ... 80 65 ... 115 58 ... 130 114 ... 217 190 ... 348 312 ... 520 Interrupting Rating: 240 V ... 35 kA 480Y/277 V ... 18 kA 600Y/347 V ... 14 kA -- -- -- -- GV4PB25B GV4PB50B GV4PB80B GV4PB115B -- -- -- -- Interrupting Rating: 240 V ... 65 kA 480Y/277 V ... 35 kA 600Y/347 V ... 18 kA GV4PB02N GV4PB03N GV4PB07N GV4PB12N GV4PB25N GV4PB50N GV4PB80N GV4PB115N GV5PB150N GV5PB250N GV6PB400N GV6PB600N Interrupting Rating: 240 V ... 100 kA 480Y/277 V ... 65 kA 600Y/347 V ... 25 kA GV4PB02S GV4PB03S GV4PB07S GV4PB12S GV4PB25S GV4PB50S GV4PB80S GV4PB115S GV5PB150S GV5PB250S GV6PB400S GV6PB600S GV5PB GV2P10 with LC1D09 GV2P + LC1D Pre-Assembled Kits Simplify your life! These new pre-assembled kits come with a GV2P manual motor protector already connected to an LC1D contactor. Panel builders and end users can now save wiring time by purchasing the pre-assembled kits. Table 18.91: Pre-Assembled Kits Components (includes GV2AF3) GV2P02 + LC1D09G7 GV2P03 + LC1D09G7 GV2P04 + LC1D09G7 GV2P05 + LC1D09G7 GV2P06 + LC1D09G7 GV2P07 + LC1D09G7 GV2P08 + LC1D09G7 GV2P10 + LC1D09G7 GV2P14 + LC1D09G7 GV2P16 + LC1D25G7 GV2P20 + LC1D25G7 GV2P21 + LC1D25G7 GV2P22 + LC1D25G7 UL File E134347 SCCR Type F 480Y/277V With GV2GH7 or GV1G09 Line Side Adapter 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 50 kA 50 kA 50 kA 50 kA With GV1G09 Line Side Adapter and GV2G Busbar 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 42 kA 42 kA 42 kA 42 kA Group Motor Rating UL File E89451 SCCR 480 V 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA 22 kA Kit Part No.[20] GV2P02KD09 GV2P03KD09 GV2P04KD09 GV2P05KD09 GV2P06KD09 GV2P07KD09 GV2P08KD09 GV2P10KD09 GV2P14KD09 GV2P16KD25 GV2P20KD25 GV2P21KD25 GV2P22KD25 Coil Voltage Suffix 120 Vac G7 24 Vac B7 24 Vdc Low Consumption BL CONTACTORS 18 AND STARTERS-IEC [20] Complete the catalog number with the coil voltage suffix (for example GV2P16KD25G7). © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-35 18 CONTACTORS AND STARTERS-IEC Motor Starters and Protectors TeSysTM Deca GV Manual Starters and Protectors Refer to Catalog MKTED210011EN and 8536CT1901 www.se.com/us TeSysTM BV4 Motor Circuit Protection Selection Providing UL508 type D combination ratings in accordance to current NEC installation requirements, the TeSys BV4 motor circuit protector allows for compact motor protection in conjunction with both the TeSys and Square DTM NEMA product families for motor control. The BV4 is a magnetic only, UL489 Listed circuit protector rated up to 100kA short-circuit protect with adjustable instantaneous trip points and can be installed directly to a panel or standard DIN rail. Motor Circuit Protectors must be applied per a listed combination motor controller rating as required by NEC and UL 508A. See UL.com/SCCR for combination ratings or contact local support for a tested combination appendix. Table 18.92: TeSysTM BV4 Motor Circuit Breaker Selection Frame BV4 MCP Ampacity (In) 2 3.5 7 13 25 50 80 115 Adjustable Instantaneous Trip (li) 12-28 21-49 42-98 53-195 110-360 176-650 320-1150 600-1150 Standard Fault Cat. No. BV4T002D BV4T003D BV4T007D BV4T013D BV4T025D BV4T050D BV4T080D BV4T115D Protection Level High Fault Cat. No. BV4T002J BV4T003J BV4T007J BV4T013J BV4T025J BV4T050J BV4T080J BV4T115J TeSysTM Deca GV2 Accessories and Enclosures Table 18.93: Mounting Accessories for GV2 + LC1 D09 to D38[21] Mount GV Directly on Single DIN Rail Mount on Single DIN Rail (Using Mounting Hardware) Mount GV and LC1D Contactor on Independent DIN Rails Mount on 2 DIN Rails (Using Mounting Hardware) GV2AF3/G2AF4 Electrical Interconnect Mounting Hardware GV2AF3 -- GK2AF01 GV1G02 -- GV2AF4 LAD311 Table 18.94: Mounting Accessories for GV2[21] Description Adapter plate 7.5 mm compensation plate Application For screw mounting of GV2M To allow mounting of GV2M and GV2P on a common bus bar Standard Pack[22] 10 10 Catalog Number GV2AF02 GV1F03 Table 18.95: Bus Bar Accessories for GV2 Description Application Type E line spacer, for use with or without GV2G busbars Incoming Terminal Type E line spacer, not for use with or with GV2G busbars Bottom Feed, for use with GV1L3 current limiter For feeding 2 GV2 starters 3-Pole, 63 A Bus Bar Protective Cover For feeding 3 GV2 starters For feeding 4 GV2 starters For feeding 5 GV2 starters To cover unused bus bar outlets Pitch -- -- -- 45 54 72 45 54 45 54 72 54 -- Catalog Number GV1G09 GV2GH7 GV2G05 GV2G245 GV2G254 GV2G272 GV2G345 GV2G354 GV2G445 GV2G454 GV2G472 GV2G554 GV1G10[23] [21] Must order in multiples of 10. [22] Orders must specify multiples of quantities listed. [23] Must order in multiples of 5. 18-36 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Deca GV Manual Starters and Protectors Refer to Catalog MKTED210011EN and 8536CT1901 Motor Starters and Protectors Table 18.96: GV2 Other Accessories Description Application Current limiter--GV2 Through-the-door operating mechanism kits Angle bracket Operating mechanism short shaft Laser tool Increases interrupt capacity when attached to GV2ME or GV2P NEMA 1, 12, Black with trip indication, for use with GV2P NEMA 1, 12, Red/Yellow with trip indication, for use with GV2P NEMA 3R, 4, 4X, Red/Yellow without trip indication, for use with GV2P Operating mechanism support shaft for deep enclosures ( 250 mm), for use with GV2P One-piece short shaft for installing operating mechanisms in shallow enclosures, for use with GV2P, GV3P and TeSys Ultra Laser tool for installing through-the-door kits Standard Pack [24] 1 1 1 1 1 1 1 Catalog Number GV1L3 GV2APN01 GV2APN02 GV2APN04 GVAPK11 GVAPA2 GVAPL01 Table 18.97: GV2 Enclosures Description Listing Enclosures for GV2ME with or without accessories CSA Listed. Not UL Listed. Mounting Surface mounting Flush mounting Flush mounting, front face reduced Enclosure Rating NEMA 1, IP41 NEMA 12/4, IP55 NEMA 1, IP41 NEMA 12/4, IP55 NEMA 1, IP41 NEMA 12/4, IP55 Max. Side Mounting Aux. Contacts Left Side Right Side 1 1 1 1 1 1 1 1 0 1 0 1 Catalog Number GV2MC01 GV2MC02 GV2MP01 GV2MP02 GV2MP03 GV2MP04 Table 18.98: GV2 Enclosures Accessories Description Type Padlocking device for GV2M (when padlocked, starter is automatically in Off -- position) Mushroom head stop push button (40 mm, red) [26] Spring return Latching Latching / Padlockable Turn to Release Turn to Release Sealing kit For enclosures GV2MC01 and GV2MP01 Standard Pack [25] 1 1 1 1 10 Catalog Number GV2V01 GV2K011 GV2K031 GV2K04 GV2E01 Voltage Trips Table 18.99: Voltage Trips Only one trip or fault signaling contact can be installed per GV2/GV3 device. Description Characteristics Voltage Frequency Voltage trips GV2 or GV3P Undervoltage or Shunt trip (external mounting, 1 block right side only) 110115 V 220240 V 60 Hz 60 Hz Cat. No. [27] GVA116 GVA226 GVAU116 Table 18.100: Voltage TripsTechnical Data (GV2AU, GV2AS) Model GVAU GVAS Inrush 12 VA / 8 W 14 VA / 10.5 W Sealed 3.5 VA / 1.1 W 5 VA / 1.6 W Rated Voltage--660 Vac Pick-Up Voltage 0.8--1.1 0.7--1.1 Drop-Out Voltage 0.35--0.7 0.2--0.75 Operating Time [28] 10--15 ms 10--15 ms CONTACTORS 18 AND STARTERS-IEC [24] Orders must specify multiples of quantities listed. [25] Supplied with IP55 sealing kit. [26] Supplied with IP55 sealing kit. [27] To order an undervoltage trip: replace the bullet () with a U (for example, GVAU025). To order a shunt trip: replace the bullet ( ) with an S (for example, GVAS025). [28] From the loss of voltage at the trip terminals to the opening of the starter contacts. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-37 18 CONTACTORS AND STARTERS-IEC Motor Starters and Protectors GVAE11 TeSysTM Deca GV Manual Starters and Protectors Refer to Catalog MKTED210011EN and 8536CT1901 www.se.com/us Table 18.101: Auxiliary Contact Blocks [29] Description Mounting Location Max. No. of Blocks Front [30][31] 1 Instantaneous auxiliary contacts GV2 or GV3P Left Hand Side 2 Fault signaling contact + instantaneous auxiliary contact GV2 or GV3P Left Hand Side [33] 1 Short circuit signaling contact GV2 or GV3P Left Hand Side 1 Contact Type N.O. or N.C. [32] N.O. + N.C. N.O. + N.O. N.O. + N.C. N.O. + N.O. N.O. (fault) + N. O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C. Sold in lots of 1 10 1 1 1 1 1 1 1 SPDT 1 Cat. No. GVAE1 GVAE11 GVAE20 GVAN11 GVAN20 GVAD1010 GVAD1001 GVAD0110 GVAD0101 GVAM11 GV3G66 Table 18.102: GV3P Accessories Accessory Application / Use With Through-the-door operating mechanism kits Angle bracket 3-pole, 115 A busbar Incoming line spacer IP 20 cover Padlocking device Operating mechanism short shaft Laser tool S-shaped busbar NEMA 1, 12, Black with trip indication, for use with GV3P NEMA 1, 12, Red/Yellow, with trip indication, for use with GV3P NEMA 3R, 4, 4X Red/Yellow without trip indication, for use with GV3P Operating mechanism support shaft for deep enclosures ( 300 mm), for use with GV3P For feeding 2 GV3P starters, 64 mm pitch For feeding 3 GV3P starters, 64 mm pitch Line spacer for GV3P when used in UL 508 Type E applications. One spacer required on line side. IP20 protective cover for ring tongue versions of GV3P and 3pole TeSysTM Deca Everlink contactors. Two covers required for line and load side. For use with up to 4 padlocks (not supplied). Ø 6 mm shank maximum One-piece short shaft for installing operating mechanisms in shallow enclosures, for use with GV2P, GV3P and TeSys Ultra Laser tool for installing through-the-door kits For connecting GV3P starters and LC1D40A-65A contactors side by side without intrawiring Standard Pack 1 1 1 1 1 1 1 1 1 1 1 1 Cat. No. GV3APN01 GV3APN02 GV3APN04 GVAPK12 GV3G264 GV3G364 GV3G66 LAD96570 GV2V03 GVAPA2 GVAPL01 GV3S Common Accessories for BV4, GV4, GV5 and GV6 Common Accessories Auxiliary contacts OF or SD Open/Closed Status Trip Alarm Open/Closed Status -- Low Level Fault signalization modules For GV4PB, SDx module mounts externally on the right side, and provides pre-trip alarm and fault signalization · SDT95% overload alarm: thermal image of the motor is greater than 95 % of the permissible temperature rise. · SDTxxs overload alarm: circuit breaker will trip in xx seconds with the same load. xx is adjustable between 10 to 40 seconds (default 20 seconds) on the circuit breaker itself through NFC or a computer with EcoStruxure Power Commission software and an interface module (TRV00911). · SDTAM overload alarm just before tripping: in the event of a phase unbalance, overload, or on a jam fault, this output is activated to open the contactor and avoid circuit breaker tripping. In that case, contact can be manually or automatically reseted after an adjustable cooling time from 1 to 15 minutes. If after a 400 ms delay the motor is not stopped, the circuit breaker will trip. · SDT overload trip indication: circuit breaker has tripped due to an overload fault. · SDJAM jam trip indication: circuit breaker has tripped due to a jam fault. · SDUNB phase unbalance trip indication: circuit breaker has tripped due to an unbalance fault. · SDLS long start trip indication: circuit breaker has tripped due to a long start fault. · SDGF ground-fault trip indication: circuit breaker has tripped due to a ground-fault. For GV5PB & GV6PB, SDx module mounts internally, and includesa pre-trip contact (400 ms prior to trip) that can be use to open the contactor, as well as a contact that indicates overload trip of the circuit-breaker. Instantaneous voltage release Undervoltage Release (Mn) 24 V 50/60 Hz 24 Vdc 48 V 50/60 Hz48 Vdc 110130 V 50/60 Hz125 Vdc 208240 V 50/60 Hz 277 V 60 Hz 380415 V 50 Hz 440480 V 60 Hz 525600 V 60 Hz Shunt Trip (Mx) 24 V 50/60 Hz 24 Vdc 48 V 50/60 Hz48 Vdc 110130 V 50/60 Hz125 Vdc BV4 Reference GV4AE11 -- -- -- GV4AU027 -- GV4AU057 GV4AU137 GV4AU247 GV4AU286 GV4AU415 GV4AU486 -- GV4AS027 -- GV4AS057 GV4AS137 GV4 Reference GV4AE11 -- -- GV4ADM1111 GV4AU027 -- GV4AU057 GV4AU137 GV4AU247 GV4AU286 GV4AU415 GV4AU486 -- GV4AS027 -- GV4AS057 GV4AS137 GV5 Reference GV7AE11 -- GV7AB11 LV429424 (1) P29404 -- GV7AU055 GV7AU107 GV7AU207 -- GV7AU387 -- P29409 P29384 -- GV7AS055 GV7AS107 GV6 Reference GV7AE11 -- GV7AB11 LV429424 (1) P29404 -- GV7AU055 GV7AU107 GV7AU207 -- GV7AU387 -- P29409 P29384 -- GV7AS055 GV7AS107 [29] One trip or one fault signaling can be fitted per GV3. [30] Cannot be used with GV2GH7 insulator. [31] Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P. [32] Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted. [33] The GVAD is always mounted next to the starter. 18-38 © 2024 Schneider Electric All Rights Reserved 3/6/2024 TeSysTM Deca Enclosed Starters Refer to Catalog MKTED210011EN www.se.com/us Common Accessories Rotary handles 208240 V 50/60 Hz 277 V 60 Hz 380415 V 50 Hz440480 V 60 Hz 525600 V 60 Hz Direct With black handle on black font With red handle on yellow font With black handle on black font Front extended IP54 With red handle on yellow font Front extended IP65 Lateral With red handle on yellow font With black handle on black font With red handle on yellow font Open door shaft operator Laser alignment tool to aid in aligning hole on door with rotary mechanism BV4 Reference GV4AS287 -- GV4AS487 -- GV4ADN01 GV4ADN02 GV4APN01 GV4APN02 GV4APN04 LV426935 LV426936 LV426937 GVAPL01 Motor Starters and Protectors GV4 Reference GV4AS287 -- GV4AS487 -- GV4ADN01 GV4ADN02 GV4APN01 GV4APN02 GV4APN04 LV426935 LV426936 LV426937 GVAPL01 GV5 Reference GV7AS207 -- GV7AS387 P29389 GV5AP03 GV7AP04 GV7AP01 (2) GV7AP02 (2) -- -- -- -- GVAPL01 GV6 Reference GV7AS207 -- GV7AS387 P29389 GV6AP03 LV432599 LV432598 (2) LV432600 (2) -- -- -- -- GVAPL01 Additional BV4 and GV4 Accessories Accessory BV4 Reference Cabling Accessories EverLink Connector (replacement) LAD96565 Large Spacing Cover for EverLink Connector (replacement) GV4G66 Crimp Lug Connector + Screws GV4LUG Transparent Terminal Shield for Crimped Lug Connector LAD96590 Interphase Barriers LV426920 One Time Torque Limiters, Green--9 N.m (set of 6) LV426990 One Time Torque Limiters, Yellow--5 N.m (set of 6) LV426992 Locking Accessories Removable Toggle Locking Device for 1 to 3 Padlocks 29370 Bag of 6 Leads + 6 Sealing Accessories LV429375 Programming Tools Pocket Battery--Allows changes to settings on the GV4PB when not powered by the line voltage -- GV4PB cord for USB Maintenance Interface -- EcoStruxure Power Commission app -- GV4 Reference LAD96565 -- GV4LUG LAD96590 LV426920 LV426990 LV426992 -- -- LV434206 TRV00917 Free download Accessory Cabling Accessories Mechanical lug kit (set of 3) Terminal Nut Insert kit/Bus Bar Connections Terminal Shield Phase Barriers Locking & Other Accessories Door Lock Toggle Extension Additional GV5 and GV6 Accessories GV5PB150.. Reference GV5PB250.. Reference 1410 AWG (2.56mm2 )--Al/Cu 142/0 AWG (2.5--70mm)--Cu 44/0 AWG (2595mm2 )--Al/Cu 3/0350 kcmil AWG (95185mm2 )--Al/Cu 1/0 AWG300 kcmil (50185mm2 )--Al/Cu 2 AWG500 kcmil (35240mm2)--Al 2 AWG600 kcmil (35300mm2)--Cu 2 AWG600 kcmil (35300mm2)--Cu 2/0 AWG500 kcmil (70240 mm2)--Al/Cu 2/0 AWG500 kcmil (70240mm2)--Cu 3/0 AWG500 kcmil (95240)--Al/Cu 3/0 AWG500 kcmil (95240)--Cu 1/420 Tap (set of 3) M10 x 25 terminal screws and washers for one side (set of 4) Short Terminal Shield Medium Terminal Shield Long Terminal Shield Phase Barriers (set of 6) AL150HD CU150HD -- -- -- -- -- -- -- -- -- S37444 -- S37447 -- -- S29329 -- -- AL175JD AL250JD CU250JD -- -- -- -- -- -- S37445 -- S37448 -- -- S29329 Removable Door lock (lock off only) Fixed Door lock (on or off) Fixed (set of 5) S29370 S29371 S29313 S29370 S29371 S29313 GV6PB.. Reference -- -- -- -- -- AL400L61K3 CU400L61K3 AL600LS52K3 CU600LS52K3 AL600LF52K3 CU600LF52K3 -- S36967 LTSS3P LTSM3P LTSL3P 32570 S29370 S32631 S432553 CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-39 Motor Starters and Protectors TeSysTM Deca Enclosed Combination Starters Refer to Catalog MKTED210011EN www.se.com/us Enclosed TeSysTM Deca Starters TeSys Deca enclosed full-voltage starters are available in Type 1 and Type 12/3R enclosures. The enclosed TeSys Deca offer accepts standard TeSys Deca accessories and all Insta-Kits control units and control power transformer kits. For additional sizes, combinations and accessory options, see Catalog 8100CT1901. Check with local sales office for availability. 18 CONTACTORS AND STARTERS-IEC LE1D093A62OB70 Table 18.103: Insta-Kits for Enclosed Full Voltage Non-Reversing Starters[34] Single-Phase 120 V 240 V 1/3 1 1/2 2 1 3 2 3 2 5 3 5 3 7.5 5 10 Max. Horsepower Ratings Three-Phase 208 V 230 V 460 V 2 2 5 3 3 7.5 5 5 10 5 7.5 15 7.5 10 20 10 10 30 15 15 40 20 20 40 575 V 7.5 10 15 20 25 30 40 50 Auxiliary Contacts On Each Contactor N.O. 1 1 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 1 1 Current Rating of Contactor 9 12 18 25 32 40 50 65 Catalog Number [35] Type 1 LE1D093A62O···· LE1D123A62O···· LE1D183A62O···· LE1D253A62O···· LE1D323A62O···· LE1D403A62O···· LE1D503A62O···· LE1D653A62O···· Type 12/3R LE1D093A72O···· LE1D123A72O···· LE1D183A72O···· LE1D253A72O···· LE1D323A72O···· LE1D403A72O···· LE1D503A72O···· LE1D653A72O···· L1 START STOP 1 23 4 AB M L2 OLR 95 96 13 14 L1 L2 OFF ON X1 X2 PL OLR 1 23 4 A B 95 96 M 61 62 X1 X2 PL Table 18.104: Voltage Codes for Enclosed Starters Primary Voltage 120 208 240 Code G7 L7 U7 TeSys Deca dimensions: TeSysTM Deca Non-Combination Starter Dimensions, page 18- 62 Insta-Kits Selection With the use of Insta-Kits, only one operator scheme is allowed. For additional accessory kits and options, see Catalog 8100CT1901. Check with local sales office for availability. L1 L2 L3 13 B MA 14 98 96 97 95 T1 T2 T3 TeSysTM Deca AC Magnetic Starter, 23 Pole L1 OFF HAND AUTO 3 4 X1 X2 PL M L2 95 96 3 4 61 62 X1 X2 PL Remote by Customer Connection From top to bottom: Start/Stop, On - Off Selector Switch, HOA Selector Switch [34] See Table 18.25 TeSysTM Deca Overload Relays--Ambient Compensated, Bimetallic, Direct Mounting, page 18-12 for field installable overload relays. [35] To obtain a single phase non-reversing starter, change prefix LE1 to LES. (e.g., LE1D093A62O···· becomes LESD093A62O····). Price remains unchanged. 18-40 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM LS1 Fuse Holders Refer to Catalog MKTED210011EN Table 18.105: Insta-Kit Accessories for Field Installation Symbol Description One operator on cover 2 Position selector switch Color Black Motor Starters and Protectors Nameplate Off - On Suffix/Cat. No. [36] NEMA Type 1 LA9CA06DT 3 Position selector switch Black Hand - Off - Auto LA9CA06ET 2 Push buttons 3 Position selector switch, Pilot light (transformer type) Green Red Black Red/Green Start Stop Hand - Off - Auto Power On LA9CA06GT LA9CA06UT TeSysTM LS1 Fuse Holders · 45 mm wide (same dimensions as GV2ME) · Mounts directly to LC1D09D38 contactors (with use of GV2AF3 or GV2AF4) · Meets application needs for fusible starter · Uses GV2AE instantaneous contact blocks to open control circuits · DIN rail mounted Table 18.106: TeSys LS1 Fuse Holders Description Screw clamp terminals, 3-pole Fuse Type CC, KTK-R Dimensions in. mm 0.41 x 1.5 10.3 x 38 Catalog Number LS1D30 E164862 CCN NLDX LR43364 Class 3211 04 LS1D30 CONTACTORS 18 AND STARTERS-IEC [36] Catalog numbers beginning with LA9 are only for starters with a "2" before the voltage code. When using a factory option that does not have a corresponding customer kit, the 10th digit of the starter must change from a "2" to a "1". © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-41 Soft Starter Module ATSU01 ATSU01 ATSU01 AltistartTM and TeSysTM Ultra Refer to Catalog MKTED210011EN www.se.com/us AltistartTM Drive and TeSysTM Ultra Motor Starter Table 18.107: Soft Start / Soft Stop Unit for 0.75 to 15 kW Motors (can be combined with the TeSys Ultra starter) Motor Motor Power, hp[1] 230 V 460 V 3-phase supply voltage: 200 to 480 V 50/60 Hz 1 2 1.5 3 2 5 3 7.5 5 10 7.5 15 10 20 Starter Nominal Current, A Catalog Number 6 ATSU01N206LT 9 ATSU01N209LT 12 ATSU01N212LT 22 ATSU01N222LT 32 ATSU01N232LT Table 18.108: Accessories Description Power connector between ATSU 01N2LT and TeSysTM Ultra Used for Starter ATSU01N2T Catalog Number VW3G4104 Table 18.109: TeSys Ultra Starter and Soft Start Unit Combinations Motor Power, hp Voltage 200 V 460 V 1 2 1.5 3 2 5 3 -- -- 7.5 5 10 7.5 15 10 20 Soft Starter ATSU01N206LT ATSU01N206LT ATSU01N209LT ATSU01N212LT ATSU01N212LT ATSU01N222LT ATSU01N222LT ATSU01N232LT TeSys Ultra Power Base Control Unit [2] LUB 12 LUB 32 LUC05BL LUC12BL LUC12BL LUC12BL LUC 18BL LUC18BL LUC32BL LUC32BL E164862 CCN NLDX LR43364 Class 3211 04 18 CONTACTORS AND STARTERS-IEC [1] Standard motor power ratings, HP power ratings indicated according to standard UL 508. [2] Depending on the configuration of the chosen TeSys Ultra starter, replace the with A for standard, B for advanced, and M for multifunction. See Table 18.75 for a complete list of available control units. Control voltage must be 24 Vdc. 18-42 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Deca Series Refer to Catalog MKTED210011EN Replacement Parts TeSysTM Deca--AC Coils Table 18.110: For LC1D09D38, LC1DT20DT40 Contactors and CAD Relays Rated Nominal Voltage 24 120 208 230/240 277 Specifications Average consumption - Inrush (inductance 0.75) - Sealed (inductance 0.3) Operating range@ 60o C Catalog Number, 50/60 Hz LXD1B7 LXD1G7 LXD1LE7 LXD1U7 LXD1W7 50/60 Hz 70 VA 7 VA 80110% of nominal @ 50 Hz, 85110% of nominal @ 60 Hz LX1D2 LX1D6 Table 18.111: For Old D2 Style LC1D40, D50, D65, D80, and D95; For TeSys Deca LC1D40A, D50A, D65A, DT60A, and DT80A; For TeSys Deca LC1D115 and D150 For TeSysTM Deca LC1D40A, D50A, D65A, DT60A, DT80A Rated Nominal Voltage, V Catalog Number 50/60 Hz For TeSysTM Deca LC1D40A, D50A, D65A, DT60A, DT80A 24 LXD3B7 120 LXD3G7[1] 208 LXD3LE7[1] 240 LXD3U7 480 LXD3T7[2] Specification 50/60 Hz Average consumption -inrush (inductance 0.3) 140 VA (Inductance: 0.9) -sealed (inductance 0.3) 7.5 VA (Inductance: 0.9) Operating range at 55 °C / 131 °F 80115% of nominal voltage For TeSysTM Deca LC1D115, D150 24 120 208 240 277 480 Specification LX1D8B7 LX1D8G7 LX1D8L7 LX1D8U7 LX1D8UE7 LX1D8T7 50/60 Hz Average consumption -inrush (inductance 0.8) 350 VA (Inductance: 0.9) -sealed (inductance 0.3) 18 VA (Inductance: 0.9) Operating range at 55 °C / 131 °F 80115% of nominal voltage Table 18.112: TeSysTM F--AC Coils (For LC1F115, F150, F185, F225, F265, F330, F400, F500, F630, F780, F800, and F1400F2100) Contactor F115-F150 Coil Part Number AC 50/60 Hz 120 V LX9FF127 240 V LX9FF220 480 V LX9FF500 24 V LX4FF024 F185-F225 LX9FG127 LX9FG220 LX9FG500 LX4FG024 F265-F330 LX1FH1272 LX1FH2402 LX1FH5002 LX4FH024 F400 F500 LX1FJ127 LX1FK127 LX1FJ240 LX1FK240 LX1FJ500 LX1FK500 Coil Part Number DC -- -- F630 LX1FL110 LX1FL220 LX1FL415 -- F780[3] LX1FX110 LX1FX220 LX1FX415 -- F800[4] LX4F8FW LX4F8MW -- -- F1400-F2100[4] LX1FK070[5] LX1FK127 LX1FK240 -- CONTACTORS 18 AND STARTERS-IEC [1] 60 Hz only [2] This coil can only be used on 60 Hz. [3] LC1F780 contactors operate with 2 coils as a set. The LX1FX· part number includes both coils. [4] Also requires rectifier DR5TE4U for 110240 V coils. [5] Order 2 coils and connect them in series. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-43 Replacement Parts LA5FG431 LA9G3QA TeSysTM Giga Series Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Giga Contact Kits, Arc Chambers Table 18.113: Replacement Contact Sets [6] Three-pole For use on contactors LC1F115, F150 LC1F185, F225 LC1F265 LC1F330, F400 LC1F500 LC1F630 LC1F780 LC1F800 Number of Poles 3 poles 3 poles 3 poles 3 poles 3 poles 3 poles 1 pole 3 poles TeSys Giga contactors: page 18-17 and page TeSys Giga overload relay accessories: page TeSys Giga replacement coils and parts: page , and page TeSys Giga dimensions: page 18-49, page 18-61 Catalog Number LA5FF431 LA5FG431 LA5FH431 LA5F400803 LA5F500803 LA5F630803 LA5F780801 [7] LA5F800803 Replaceable Switching Modules · Innovative contact switching modules for TeSysTM Giga Contactors · Replace worn-out poles with a new switching module in minutes, without having to disassemble the entire product. · No special tools are needed for the replacement Table 18.114: TeSysTM Giga Switching modules for TeSys Giga contactors (Standard and Advanced versions) Description Suitable for: For contactors Reference 3 or 4 switching module kits 3-pole 4-pole LC1G115/LC1G225 LC1G265/LC1G330 LC1G400/LC1G500 LC1G630/LC1G800 LC1G115/LC1G225 LC1G265/LC1G330 LC1G400/LC1G500 LC1G630/LC1G800 LA9G3QA LA9G3RA LA9G3SA LA9G3TA[8] LA9G4QA LA9G4RA LA9G4SA LA9G4TA[8] NOTE: During replacement, replace all switching modules. After replacement, change the position of the RESET button on the control module from A to B or B to A. 18 CONTACTORS AND STARTERS-IEC [6] Supplied per pole are: 2 fixed contacts, 1 moving contact, 2 deflectors, 1 backplate, mounting screws and washers. [7] Two identical components per pole are supplied. [8] Available 2Q 2022. 18-44 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us AK5JB busbar AK5PA231 AK5PA232S TeSysTM AK5 Panel Busbar System Refer to Catalog MKTED210011EN Wiring Systems TeSysTM AK5 Panel Busbar System The AK5 pre-fabricated bus bar system provides a quick and easy method of mounting control devices. All components are finger safe, UL Listed, CSA approved and CE marked. Although the AK5 system can be screw mounted onto any type of support, it must be mounted on the AM1DL201 DIN rail when component mounting plates incorporating a tap-off are used. When using tap-offs, the nominal operating current of the bus bar (160 A @ 35°) must not be exceeded. Approvals include IEC 439, UL, CSA, DNV and LROS. Table 18.115: 160 A, 3-Phase Busbar System Maximum number of mounting plates Tap-off 1.42 in. 36 mm 15 24 Standard Width Plate 2.13 in. 54 mm 10 16 Extension Plate 2.80 in. 71 mm 5 8 Length in. mm 26.05 668 38.69 992 Catalog Number AK5JB146 AK5JB149 Table 18.116: Mounting Plate Tap-off (plugs into busbar mounted on AM1DL201 DIN rail) Width in. mm 2.13 54 2.13 54 Thermal Current Amperes 25 A 25 A Application GV2 with LUS or LUB 12 and 32 contactor Catalog Number AK5PA231 AK5PA232 Table 18.117: Bus Tap-off (plugs into busbar for wiring to a separately mounted device) Width in. mm 1.42 36 1.42 36 Thermal Current (A) 32 A 32 A Length of Leads in. mm 9.84 250 39.37 1000 Catalog Number AK5PC33 AK5PC33L Table 18.118: Mounting Rail (must be used for mounting plates with tap-offs) Description 75 mm Omega Rail Depth mm 15 Length mm 2000 Catalog Number AM1DL201 File E161251 CCN NMTR File LR 89150 Class 6228-01 AK5PC33 AM1DL201 CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-45 Dimensions TeSysTM Deca Non-Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSysTM island Load Management System Module Dimensions mm in. Size 1 Starters: TPRST009 and TPRSS009 mm in. Size 2 Starters: TPRST025, TPRST038, TPRSS025 and mm in. 101 3.97 121 4.76 121 4.76 114 4.48 50 Bus Coupler: TPRBCEIP 1.96 Size 3 Starters: TPRST065, TPRST080, TPRSS065 and mm in. 115 4.53 45 1.77 Size 1 (TPRPM009) and Size 2 (TPRPM038) Power Interface mm in. 115 4.53 45 TPRSS038 1.77 Size 3 (TPRPM080) Power Interface Module mm in. 121 4.76 136 162 5.34 6.38 125 4.92 55 2.16 TPRSS080 SIL Interface Module: TPRSM001 mm in. 115 4.53 Module Voltage Interface Module: TPRVM001 mm in. 45 1.77 Digital I/O Module: TPRDG4X2 mm in. 125 4.92 55 2.17 Analog I/O Module: TPRAN2X1 mm in. 18 CONTACTORS AND STARTERS-IEC 101 3.97 101 3.97 101 101 3.97 3.97 114 4.48 25 .98 114 4.48 25 .98 114 4.48 25 .98 114 4.48 25 .98 TeSysTM Deca Contactors, AC and DC Coil Table 18.119: TeSys Deca 9 to 38 A Contactors, AC and DC Coils LC1D09 to D18 Minimum electrical clearance 1.73 44 LC1D25 to D38 (3-pole) and LC1DT20 to DT40 (4pole) Minimum electrical clearance LA4 b b1 b .39 c 10 c1 c2 c3 TeSys Deca contactors: LC1D AC coil, without add-on accessories b DC coil AC coil, with LAD4BB AC coil, with LA4D*2 b1 AC coil, with LA4DF, DT AC coil, with LA4DR, DW, DL AC coil, without cover or add-on blocks AC coil, with cover, without add-on blocks c DC coil, without cover or add-on blocks DC coil, with cover, without add-on blocks AC coil, with LADN or C (two or four contacts) c1 DC coil, with LADN or C (two or four contacts) c2 AC coil, with LAD6K10 .51 1.77 13 45 (LAD8) D09 to D18 in. (mm) 3.03 (77) 3.03 (77) 3.70 (94) 4.33 (110) [1] 4.68 (119) [1] 4.96 (126) [1] 3.30 (84) 3.38 (86) 3.66 (93) 3.76 (95) 4.60 (117) 4.96 (126) 5.07 (129) D25 to D38 in. (mm) 3.36 (85) 3.36 (85) 3.85 (98) 4.48 (114) [1] 4.84 (123) [1] 5.11 (130) [1] 3.54 (90) 3.62 (92) 3.89 (99) 3.97 (101) 4.84 (123) 5.19 (132) 5.31 (135) .39 c 10 c1 c2 c3 D098, D128, DT20, DT25 in. (mm) 3.34 (85) 3.34 (85) 3.85 (98) 4.48 (114) 5.02 (129) 7.48 (190) 3.54 (90) 3.62 (92) -- 3.90 (99) 4.84 (123) 4.84 (123) 5.31 (135) 1.77 45 DT32, DT40 in. (mm) 3.58 (91) 3.58 (91) -- -- -- -- 3.85 (98) 3.93 (100) -- 4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143) D188, D258 in. (mm) 4.13 (105) 4.13 (105) -- -- -- -- 3.85 (98) 3.93 (100) -- 4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143) [1] Including LAD4BB. 18-46 © 2024 Schneider Electric All Rights Reserved 3/6/2024 b CONTACTORS 18 AND STARTERS-IEC www.se.com/us TeSysTM Deca Non-Reversing Contactors Refer to Catalog MKTED210011EN Table 18.119 TeSys Deca 9 to 38 A Contactors, AC and DC Coils (cont'd.) LC1D09 to D18 Minimum electrical clearance 1.73 44 LA4 Dimensions LC1D25 to D38 (3-pole) and LC1DT20 to DT40 (4pole) Minimum electrical clearance b b1 .39 c 10 c1 c2 c3 TeSys Deca contactors: LC1D DC coil, with LAD6K10 AC coil, with LADT, R, S AC coil, with LADT, R, S and sealing cover c3 DC coil with LADT, R, S DC coil with LADT, R, S and sealing cover .51 1.77 13 45 (LAD8) D09 to D18 in. (mm) 5.43 (138) 5.39 (137) 5.55 (141) 5.76 (146) 5.90 (150) D25 to D38 in. (mm) 5.66 (144) 5.62 (143) 5.78 (147) 5.98 (152) 6.14 (156) .39 c 10 c1 c2 c3 D098, D128, DT20, DT25 in. (mm) 5.31 (135) 5.62 (143) 5.78 (147) 5.62 (143) 5.78 (147) 1.77 45 DT32, DT40 in. (mm) 5.62 (143) 5.94 (151) 6.10 (155) 5.94 (151) 6.10 (155) D188, D258 in. (mm) 5.62 (143) 5.94 (151) 6.10 (155) 5.94 (151) 6.10 (155) Table 18.120: TeSys Deca 40 A to 65 A, AC and DC coil LC1 D40AD65A (3P), LC1 DT60ADT80A (4P) AC OR DC LA4 DpB a Min. electrical clearance LAD 4BB3 b1 DF569184.eps 4.80 122 4.6 117 b1 .47 c 12 c1 c2 c3 c c1 LAD 4BB3 c2 LA4 DpB 5 (125) a 5 (125) c3 (LAD 8N) (LAD 8N) LC1 with LA4 D2 with LA4 DB3 or LAD 4BB3 with LA4 DF, DT with LA4 DM, DW, DL without cover or add-on blocks with cover, without add-on blocks with LADN (1 contact) with LADN or C (2 or 4 contacts) with LAD 6K10 or LA6 DK with LADT, R, S with LADT, R, S and sealing cover D40AD65A in. (mm) 2.17 (55) -- 5.35 (136) 6.18 (157) 6.54 (166) 4.65 (118) 4.72 (120) -- 5.91 (150) 6.42 (163) 6.73 (171) 6.89 (175) DT60ADT80A in. (mm) 2.76 (70) -- -- -- -- 4.65 (118) 4.72 (120) -- 5.91 (150) 6.42 (163) 6.73 (171) 6.89 (175) Table 18.121: TeSys Deca D80 and D95 AC Coil LC1D80 and D95 (3P), LP1 D80004 and D80008 (4P) 1.26 1.73 a 32 44 LA4 b1 5 (127) b1 .47 c 12 c1 c2 c3 5 (125) (LAD 8) c c1 c2 a 5 (125) (LAD 8) c3 LC1 with LA4 D2 with LA4 DB3 or LAD 4BB3 with LA4 DF, DT with LA4 DM, DW, DL without cover or add-on blocks with cover, without add-on blocks with LADN (1 contact) with LADN or C (2 or 4 contacts) with LAD 6K10 or LA6 DK with LADT, R, S with LADT, R, S and sealing cover D80 in. (mm) 3.35 (85) 5.31 (135) 5.31 (135) 5.59 (142) 5.90 (150) 4.92 (125) 5.12 (130) 5.90 (150) 6.22 (158) 6.69 (170) 7 (178) 7.16 (182) D95 in. (mm) 3.35 (85) 5.31 (135) -- 5.59 (142) 5.90 (150) 4.92 (125) 5.12 (130) 5.90 (150) 6.22 (158) 6.69 (170) 7 (178) D80004 in. (mm) 3.78 (96) 5.31 (135) -- 5.59 (142) 5.90 (150) 4.92 (125) -- 5.90 (150) 6.22 (158) 6.69 (170) 7 (178) D80008 in. (mm) 3.78 (96) 5.31 (135) -- 5.59 (142) 5.90 (150) 5.51 (140) -- 5.90 (150) 6.22 (158) 6.69 (170) 7 (178) 7.16 (182) 7.16 (182) 7.16 (182) © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-47 Dimensions TeSysTM Deca Non-Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us 5 (127) b1 Table 18.122: DC Coil LC1D80, D95 (3P), LP1D80004, D80008 (4P) Minimum electrical clearance 1.26 1.73 32 44 LA4 .47 c 12 c1 c2 c3 5 (125) a (LAD 8) TeSysTM Deca Contactors, DC Coil 5 (125) (LAD 8) D80 and D95 LC1 in. (mm) a 3.35 (85) b1 with LAD 4BB3 with LA4 DF, DT -- -- without cover or add-on blocks 7.13 (181) c with cover, without add-on blocks 7.32 (186) with LAD N (1 contact) 8.03 (204) c1 with LAD N or C (2 or 4 contacts) 8.27 (210) c2 with LA6 DK10 8.70 (221) with LAD T, R, S 9.01 (229) c3 with LAD T, R, S and sealing cover 9.17 (233) D80004 in. (mm) 3.78 (96) -- -- 7.13 (181) -- 8.03 (204) 8.27 (210) 8.70 (221) 9.01 (229) 9.17 (233) D80008 in. (mm) 3.78 (96) -- -- 7.72 (196) -- 8.03 (204) 8.27 (210) 8.70 (221) 9.01 (229) 9.17 (233) 6.22 158 b1 LC1D115, D150 (3P), LC1D115004 (4P), AC and DC Coils Panel mounted with 1/4" screws Min. electrical clearance LA4 .39 10 LAD 8 c a c1 c2 c3 With 2 or 4 contacts. + 4 mm with sealing cover. D115, D150 LC1 in. (mm) a 4.72 (120) with LA4DA2 6.85 (174) with LA4DF, DT b1 with LA4DM, DL 7.28 (185) 7.40 (188) with LA4DW 5.20 (132) without cover or add-on blocks 5.35 (136) c with cover, without add-on blocks 5.35 (136) c1 with LAD N or C (2 or 4 contacts) 5.91 (150) c2 with LA6DK20 6.10 (155) with LAD T, R, S 6.61 (168) c3 with LADT, R, S and sealing cover 6.77 (172) D115004 in. (mm) 5.91 (150) 6.85 (174) 7.28 (185) 7.40 (188) 5.20 (132) -- -- 5.91 (150) 6.10 (155) 6.61 (168) 6.77 (172) D1150046 in. (mm) 6.10 (155) 6.85 (174) 7.28 (185) 7.40 (188) 4.53 (115) -- -- 5.91 (150) 6.10 (155) 6.61 (168) 6.77 (172) 18 CONTACTORS AND STARTERS-IEC 18-48 © 2024 Schneider Electric All Rights Reserved 3/6/2024 CONTACTORS 18 AND STARTERS-IEC X1 X1 www.se.com/us LC1F115 to F330 (1) L c (1) Protective cover Type LA9F70· = b = b2 TeSysTM F Non-Reversing Contactors Refer to Catalog MKTED210011EN Dimensions S s1 (2) M Q P P Q1 a f (2) Optimal terminal shroud J J1 b1 = TeSysTM F Contactors, Dimensions All dimensions shown in mm. To convert to inches, divide by 25.4. Table 18.123: LC1F115F330 Dimensions F115 F150 F185 LC1 3-Pole 4-Pole 3-Pole 4-Pole 3Pole 4Pole a 163.5 200.5 163.5 200.5 168.5 208.5 b 162 162 170 170 174 174 b1 137 137 137 137 137 137 b2 265 265 301 301 305 305 c 165 [2] 165 [2] 165 [2] 165 [2] 176 176 f 131 131 131 131 130 130 G 106 143 106 143 111 151 G1 80 80 80 80 80 80 J 106 106 106 106 106 106 J1 120 120 120 120 120 120 L 107 107 107 107 113.5 113.5 M 147 147 150 150 154 154 P 37 37 40 40 40 40 Q 29.5 29.5 26.5 26 29 29 Q1 60 60 57.5 55.5 59.5 59.5 S 15 15 20 20 20 20 S1 27 27 34 34 34 34 Y 44 44 44 44 44 44 Z 13.5 13.5 13.5 13.5 13.5 13.5 f = minimum distance required for coil removal. F225 3- 4- Pole Pole 168.5 208.5 197 197 137 137 364 364 181 181 130 130 111 151 80 80 106 106 120 120 113.5 113.5 172 172 48 48 21 17 51.5 47.5 25 25 44.5 44.5 44 44 13.5 13.5 F265 3- 4- Pole Pole 201.5 243.5 203 203 145 145 370 370 207 207 147 147 142 190 96 96 106 106 120 120 141 141 178 178 48 48 39 34 66.5 66.5 25 25 38 38 38 38 21.5 21.5 F330 3- 4- Pole Pole 213 261 206 206 145 145 375 375 219 219 147 147 154.5 202.5 96 96 106 106 120 120 145 145 181 181 48 48 43 43 74 74 25 25 44.5 44.5 38 38 20.5 20.5 Table 18.124: LC1F115F330 Voltage 200 to 500 V LC1F115, F150 10 LC1F185 10 LC1F225, F265 10 LC1F330 10 X1: Minimum clearance according to the operational voltage and the breaking capacity. 600 to 1000 V 15 15 15 15 = LC1F400 to F500 2.20 56 X1 L c (1) Protective cover 8.23 209 = b = b2 = G1 = Z G Y (1) S 1.49 38 M10 X 30 dia. M Q P P Q1 a f 8 X 8.5 dia. 4.7 = 120 7.09 = 180 Table 18.125: LC1F400F500 Dimensions LC1 2-Pole F400 3-Pole 4-Pole 2-Pole a 213 213 261 233 b 206 206 206 238 b2 375 375 375 400 c 213 213 213 226 f G [3] 119 119 119 141 80 80 80 80 G min. 66 66 66 66 G max. 102 102 150 120 G1 [3] 170 170 170 170 G1 min. 156 156 156 156 G1 max. 192 192 240 210 J 19.5 19.5 67.5 39.5 L 145 145 145 146 M 181 181 181 208 P 48 48 48 55 Q 69 43 43 76 Q1 96 74 74 102 S 25 25 25 30 f = Minimum distance required for coil removal. F500 3-Pole 233 238 400 226 141 80 66 120 170 156 210 39.5 146 208 55 46 77 30 4-Pole 288 238 400 226 141 140 66 175 230 156 265 34.5 146 208 55 46 77 30 Table 18.126: LC1F400F500 Voltage 200 to 500 V 600 to 1000 V LC1F400 15 20 LC1F500 15 20 X1: Minimum clearance according to the operational voltage and the breaking capacity. = = G .92 G1 J 23.5 [2] +6 mm with time delay block (for F115 and F150). [3] Supplied. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-49 Dimensions Table 18.127: LC1F Dimensions LC1F630 and LC1F800 2.83 72 c TeSysTM F Non-Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us 2.52 1.57 64 40 6 x M12 x 45 4 x Dia. 10.5 mm = = 180 7.09 304 11.97 10.39 264 = 18.28 464 280 11.02 2.38 G J1 60 = X1 6.10 155 7.76 197 9.84 250 X1: Minimum clearance according to the operational voltage and the breaking capacity. Q 3.15 3.15 Q1 80 80 a 7.13* 181 * = minimum distance required for coil removal. Protective terminal cover. LC1F630 2P 3P 4P a 12.17 309 12.17 309 15.31 389 G supplied G min. G max. J1 Q Q1 7.09 180 3.94 100 7.68 195 2.70 68.5 4.02 102 5.00 127 7.09 180 3.94 100 7.68 195 2.70 68.5 2.36 60 3.50 89 9.45 240 5.91 150 10.83 275 2.70 68.5 2.36 60 3.50 89 Voltage (V) F630 F800 200500 V 20 -- 6901000 V 30 -- 200690 V -- 10 1000 V -- 20 LC1F780, F7804 = 2.36 60 1.02 26 12 x M14 x 45 1.02 26 X1 18 CONTACTORS AND STARTERS-IEC 280 11.02 .86 22 434 17.08 13.70 348 X1 15.74 400 = 6.50 165 9.84 250 X1: Minimum clearance according to the operational voltage and the breaking capacity. Voltage (V) 200500 V 6901000 V X1 in mm 30 35 7.20* 183 7.52 6.30 191 160 27.64 (1) 702 1) Overall length (3 poles). 2) Overall length (4 poles). * Minimum distance required for coil removal. LC1F780 mounting LC1F7804 mounting 6.30 7.52 160 191 33.93 (2) 862 7.20* 183 127 5.00 127 5.00 6 x Dia. 10.5 mm 8 x Dia. 10.5 mm 180 7.09 180 7.09 127 5.00 127 5.00 3.50 9.45 90 240 18-50 9.45 5.20 240 132 3.50 9.45 90 240 7.48 9.45 4.00 190 240 102 © 2024 Schneider Electric All Rights Reserved 3/6/2024 TeSysTM F Non-Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us LC1 F1000, LC1 F1400, LC1 F1700 and LC1 F2100 112299,,77 112299,,77 == 3344 == 2244xxØØ1144 Dimensions 4xØ10x15 3344 229988 DB419751.eps 185 == XX11 DB402359.eps 333322 221100 XX11 == LLCC11FF11770000::8844,,99 1144 113377,,33 LLCC11FF22110000::9911 223388,,66 220000((11)) 443388 X1: Minimum clearance according to the operational voltage and the breaking capacity. 1) Minimum distance required for coil removal. Voltage (V) 200500 V X1 in mm 90 220000((11)) 240 50 190 6901000 V 100 50 49,5 CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-51 Dimensions TeSysTM Deca Reversing Contactors Refer to Catalog MKTED210011EN Table 18.128: Reversing Contactor Dimensions LC2D09D38 2 x LC1D09 to D38 TeSysTM Deca Reversing Contactor Dimensions 2xM4 LC2DT20 to DT40 2 x LC1 DT20 to DT40 www.se.com/us 2xM4 = 2.36/2.76 = 60/70 b = 2.36/2.76 = 60/70 e1 b c LC2 or 2 x LC1 a in. (mm) D09 to D18 (AC Coil) 3.54 (90) D093 to D123 (AC Coil) 3.54 (90) D09 to D18 (DC Coil) 3.54 (90) D093 to D123 (DC Coil) 3.54 (90) D25 to D38 (AC Coil) 3.54 (90) D183 to D383 (AC Coil) 3.54 (90) D25 and D32 (DC Coil) 3.54 (90) D183 to D383 (DC Coil) 3.54 (90) e1 and e2: includes cabling b in. (mm) 3.03 (77) 3.9 (99) 3.03 (77) 3.9 (99) 3.34 (85) 3.9 (99) 3.34 (85) 3.9 (99) e2 = c [4] in. (mm) 3.38 (86) G a e1 in. (mm) 0.16 (4) 3.38 (86) -- 3.74 (95) 0.16 (4) 3.74 (95) -- 3.62 (92) 0.35 (9) 3.62 (92) -- 3.98 (101) 0.35 (9) 3.98 (101) -- = e2 in. (mm) 0.06 (1.5) -- 0.06 (1.5) -- 0.20 (5) -- 0.20 (5) -- LC2D40A to D65A 2 x LC1D40A to D65A 1.48 1.04 1.48 6xM4 37.5 26.5 37.5 G in. (mm) 3.14 (80) 3.14 (80) 3.14 (80) 3.14 (80) 3.14 (80) 3.14 (80) 3.14 (80) 3.14 (80) c e2 LC2 or 2 x LC1 DT20 and DT25 (AC Coil) DT32 and DT40 (AC Coil) DT20 and DT25 (DC Coil) DT32 and DT40 (DC Coil) a in. (mm) 3.54 (90) 3.54 (90) 3.54 (90) 3.54 (90) c, e: includes cabling = b in. (mm) 3.34 (85) G a c in. (mm) 3.62 (92) = G in. (mm) 3.14 (80) 3.58 (91) 3.9 (99) 3.14 (80) 3.34 (85) 4 (102) 3.14 (80) 3.58 (91) 4.29 (109) 3.14 (80) 18 CONTACTORS AND STARTERS-IEC 4.80 122 5.04 128 4.72 120 LC2D80 and D95 2 x LC1D80 and D95 (AC Coil) 0.74 18.7 2.52 0.74 64 18.7 4.69 119 2 x LC1D80 and D95 (DC Coil) 6xØ0.26 6xØ6.5 = G1 = e1 8 .31 100 110 3.94 4.33 b 13 LC2 or 2 x LC1 a b in. (mm) in. (mm) D80 and D95 7.17 (182) 5 (127) D80004 8.15 (207) 5 (127) c, e1, and e2: includes cabling c in. (mm) 6.22 (158) 6.22 (158) e1 in. (mm) 0.51 (13) -- e2 in. (mm) -- 0.79 (20) G in. (mm) 2.24 (57) 2.8 (71) G1 in. (mm) 3.78 (96) 4.37 (111) c 2 x LC1 D80 and D95 a in. (mm) 8.15 (207) b in. (mm) 5.0 (127) c, e1 and e2: includes cabling. e2 = 1.57 G 40 a c in. (mm) 8.46 (215) e1 in. (mm) 0.51 (13) e2 in. (mm) 0.79 (20) 1.57 = 40 .51 G in. (mm) 3.78 (96) G1 in. (mm) 4.37 (111) [4] With safety cover, without add-on block. 18-52 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us LC2D115 and D150 2 x LC1D115 and D150 TeSysTM Deca Reversing Contactors Refer to Catalog MKTED210011EN Dimensions e1 = 130 5.12 158 6.22 = e2 LC2 or 2 x LC1 D115, D150 D115004 c, e1 and e2 includes cabling c a in. (mm) 10.47 (266) 13.15 (334) = c in. (mm) 5.83 (148) 5.83 (148) G = a e1 in. (mm) 2.2 (56) -- e2 in. (mm) 0.71 (18) 2.36 (60) G in. (mm) 9.53/10.08 (242/256) 12.2/12.76 (310/324) NOTE: For dimensions of TeSys F reversing contactors, please refer to catalog MKTED210011EN. CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-53 Dimensions TeSysTM Deca Open Starters Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Deca Open Starter Dimensions Table 18.129: TeSys Deca Thermal Overload Relay Dimensions, in. (mm) LRD01-35 Direct mounting beneath contactors with screw clamp connections LRD04L-32L Direct mounting beneath contactors with screw clamp connections c DB415912.eps b LC1 b c D09D18 D25D38 4.84 (123) 5.39 (137) See page 18-46 LR9D01, 02, 08, and 32 c LC1 b c 3 76.1 D09D18 4.84 (123) 1.77 45 See page 18-46 D25D38 5.39 (137) LRD313365 Direct mounting beneath LC1D40A to D65A with screw clamp connectionsor EverLink connectors 7.28 115 4.53 b 4.96 126 70 2.75 1.77 3.15 45 80 LC1 D09D18 D25D38 b 5.12 (130) 5.51 (140) c See page 18- See page 18- 46 46 4.84 123 2.16 55 LRD33 Direct mounting beneath contactors LC1D80 to D95 185 18 CONTACTORS AND STARTERS-IEC 18-54 AM1 d LC1D80 LC1D95 LP1D80 b 4.55 (115.5) 4.55 (115.5) 4.55 (115.5) DL201 0.28 (7) c e AC Control Circuit 4.88 (124) 3.03 (76.9) 4.88 (124) 3.03 (76.9) DC Control Circuit 7.06 (179.4) 3.03 (76.9) DL200 0.67 (17) g (3P) 0.37 (9.5) 0.37 (9.5) 0.37 (9.5) g (4P) 0.87 (22) -- 0.87 (22) © 2024 Schneider Electric All Rights Reserved 3/6/2024 TeSysTM Deca Open Starters Refer to Catalog MKTED210011EN www.se.com/us LRD4[5] Direct mounting beneath contactors LC1D115 and D150 LR9D5 and LR9D6[5] Direct mounting beneath contactors LC1D115 and D150 Dimensions 6.85 174 10.04 5.35 255 136 AM1 d DL200 and DR200 0.10 (2.5) DE200 and ED 0.41 (10.5) 5.20 132 AM1 d d DP200 and DR200 0.10 (2.5) 4.72 120 DE200 and ED 0.41 (10.5) CONTACTORS 18 AND STARTERS-IEC [5] For additional specifications and selection information, see catalog MKTED210011EN © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-55 Dimensions TeSysTM Giga Contactors -- Dimensions Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Giga Contactors (Dimensions) Table 18.130: Standard Version LC1G630...800 TeSysTM Giga High Power Contactors 3-Pole 4-Pole -- All dimensions are in mm. X1 (mm) = Minimum electrical clearance. LC1G115...800, up to 1000 V: 40 mm. X2 (mm) = Minimum electrical clearance according to operating voltage inside metallic cabinets/adjacent installation of contactors. LC1G115...800, up to 600 V: 5 mm. Table 18.131: Standard Version -- 3-Pole a b c G J M H L P Q S Ø 210 284 265 70 242 244 192 107 70 35.3 48 13 Table 18.132: Standard Version -- 4-Pole a b c G J M H L P Q S Ø 280 284 265 140 242 244 192 107 70 35.3 48 13 Table 18.133: Mechanical Interlock Description Mechanical Interlock (between the same frame sizes) LC1G115 to 225 (3-Pole and 4-Pole) LC1G265 to 500 (3-Pole and 4-Pole) LC1G630 to 800 (3-Pole) Mechanical Interlock (between different frame sizes) LC1G265 to 500 and LC1G115 to 225 (3-Pole and 4-Pole) LC1G630 to 800 and LC1G265 to 500 (3-Pole) Reference LA9G970 LA9G973 LA9G971 LA9G972 18 CONTACTORS AND STARTERS-IEC 18-56 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM Giga Contactors -- Dimensions Refer to Catalog MKTED210011EN Dimensions Table 18.134: Advanced Version LC1G630...800 TeSysTM Giga High Power Contactors 3-Pole 4-Pole All dimensions are in mm. X1 (mm) = Minimum electrical clearance. LC1G115...800, up to 1000 V: 40 mm. X2 (mm) = Minimum electrical clearance according to operating voltage inside metallic cabinets/adjacent installation of contactors. LC1G115...800, up to 600 V: 5 mm Table 18.135: Advanced Version -- 3-Pole a b c G J M H L P Q S Ø 210 388.5 265 70 242 346.5 192 107 70 35.3 48 13 Table 18.136: Advanced Version -- 4-Pole a b c G J M H L P Q S Ø 280 388.5 265 140 242 346.5 192 107 70 35.3 48 13 CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-57 18 CONTACTORS AND STARTERS-IEC Dimensions TeSysTM Deca Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Deca Thermal Overload Relay Dimensions LRD0135 Independent mounting on 1.97 in. (50 mm) centers or on rail AM1DP200 or DE200 Independent mounting on 4.33 in. (110 mm) centers LAD 7B106 1.81 46 = = DF533590.eps = LAD 7B106 1.38 0.39 35 10 DF533589.eps 110 4.33 4.92 125 50 15 0.20 1.97 .59 1.48 37.5 3.35 85 5 0.24 6 3.15 0.08 1.77 80 2 45 LRD04L32L Independent mounting on 1.97 in. (50 mm) centers or on rail AM1DP200 or DE200 LAD 7B205 1.38 0.39 35 10 3.54 DX1 AP25 2xØ6.5 90 Independent mounting on 4.33 in. (110 mm) centers LAD 7B205 1.81 46 = = = DB415879.eps DB415878R.eps = 50 15 0.24 1.97 .59 1.48 37.5 3.35 85 110 4.33 4.92 125 5 0.24 6 3.39 0.08 1.77 86.1 2 45 AM1 d DP200 0.08 (2) LRD313365 Mounting on rail AM1D200 or ED200 With terminal block LAD96560 LAD 96560 DE200 0.37 (9.5) Panel mounting Outgoing terminal block not shown (1) DX1 AP25 2xØ6.5 Mounted on plate AM1P LAD 96560 AF1 EA4 = 2 2.91 74 2.83 0.08 72 3.42 87 4.57 d 2.16 116 55 AM1 d DP200 0.08 (2) DE200 0.37 (9.5) ED200 0.37 (9.5) 1.69 43 (1) 2 elongated holes Ø 4.2 x 6. LRD0135 and LRD313365 Remote tripping or electrical reset DF536769.eps LAD 703 (1) 1.26 32 (1) Can only be mounted on RH side of relay 0.08 2 1.69 43 18-58 © 2024 Schneider Electric All Rights Reserved 3/6/2024 TeSysTM Deca Overload Relays Refer to Catalog MKTED210011EN www.se.com/us LR9D01D32 LAD 7B205 1.38 0.39 35 10 LR9D110S Dimensions 2.56 65 = 1.97 = 50 2.95/3.42 75/87 2.03 51.5 4.72 120 1.48 37.5 3.35 85 0.24 6 0.20 1.97 .59 5 50 15 3.39 0.08 1.77 86.1 2 45 LRD3 and LR2D35 Independent mounting on 1.97 in. (50 mm) centers or on rail AM1DP200 or DE200 LA7 D3064 2.95 = 1.97 75 = 50 4.49 d 114 LRD3, LR2D35, and LR9D5 Remote tripping or electrical reset 2xØ4.5 LA7 D03 (1) DF533595.eps DF533594.eps 2.03 51.5 3.94 100 0.08 2 2.95/3.42 75/87 4.76 121 AM1 d d 2xØ4.5 DP200 0.08 (2) 4.68 0.83 119 21 0.92 1.26 23.5 32 DE200 0.37 (9.5) (1) Can be mounted on RH or LH side of relay LRD3, LR2D35, or LR9D LRD3 Adapter for door-mounted operator LA7 D1020 c 0.39 10 Stop Reset DF533596.eps LA7 D1020 c: adjustable from 0.67 to 4.72 (17 to 120) LRD, LRD313365, LRD0432L, LR9D5, and LR9D6 "Reset" by flexible cable LA7D305 and LAD7305 Mounting with cable straight Mounting with cable bent DF533597.eps e c e: up to 1.18 (20) c: up to 21.65 (550) e e: up to 1.18 (20) M10x1 DF564938.eps DF533598.eps DF564939.eps CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-59 J M B X1 H Dimensions TeSysTM Giga Overload Relays -- Dimensions Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Giga Overload Relays (Dimensions) Table 18.137: TeSysTM Giga Overload Relays, Dimensions -- LR9G115...630 S1 Ø1 C L Ø2 S2 Q P P P a G1 Ø3 LR9G a b c G1 G2 J M H L P Q S1 S2 Ø1 Ø2 Ø3 X1 G2 115...225 105.7 109.55 126.2 70 35 80.1 78 52 66 35 18 11.5 17.5 8.3 9 5.3 30 500 140 115.65 139.2 119.3 45 68.25 83 47 79 45 25 22.5 30.5 10.6 10.6 5.3 33 630 210 149.45 185.9 186.2 70 87 100 47 107 70 35 22.5 50 13 13 8.5 50 18 CONTACTORS AND STARTERS-IEC 18-60 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM F Overload Relays Refer to Catalog MKTED210011EN Dimensions Table 18.138: TeSys F Overload Relay Dimensions LR9F571, F71 Common side view 4.88 124 (1) .11 3 2.24 57 1.89 1.89 48 48 Ø11 .98 25 TeSysTM F Overload Relay Dimensions All dimensions shown in mm. To convert to inches, divide by 25.4. 4.72 120 1.97 1.97 50 50 LR9F557, F563, F567, F569, F57, F63, F67, F69 1.97 1.97 50 50 (2) 1.57 1.57 40 40 .22 6 6 .22 60 2.36 3.78 96 2.99 76 71 2.80 2.80 71 60 2.36 1.77 45 3.98 101 2.99 76 H3 CONTACTORS 18 AND STARTERS-IEC 4.53 .11 1.85 115 3 47 1) Terminal shroud LA9F70· 4xØ5.5 LR9F775, F779, F781, F75, F79, F81 Common side view 5.04 128 (1) 1.65 42 14 .55 P1 P2 1.18 Ø11 30 4xØ5.5 .79 20 4.53 115 4xØ5.5 2) 6.5 x 13.5 for LR9F5·57 and F57. 8.5 x 13.5 for LR9F5·63, F5·67, F5·69, F63, F67, F69. LR9F781, F81 (for mounting beneath LC1F630 and LC1F800) 7.87 200 3.15 3.15 Ø13 80 80 1.57 40 .79 20 2.44 62 70 22 2.76 .87 .24 6 3.23 82 5.39 137 1.77 45 109 4.29 9.02 229 7.44 189 .98 25 .24 2.05 2.05 6 52 2.60 52 2.60 66 66 5.94 151 (1) Terminal shroud LA9-F70· P1 P2 LR9F775, F75 48 48 LR9F779, F781, F79, F81 55 55 Direct mounting beneath contactor LC1F 1.57 40 3.03 3.03 77 77 7.60 193 Direct mounting beneath reversing contactors or star-delta contactors H3 b b H4 H1 LA7F40· Busbar (1) H2 H2 (2) (2) Relay mounting plate, see . (1) Connection accessories, see . (2) Relay mounting plate, see . LC1 contactors With LR9 relays b H1 H2 H3 F115 F557, F563, F567, F569, F57, F63, F67, F69 240 30 76 120 F150 F557, F563, F567, F569, F57, F63, F67, F69 246 30 76 120 F185 F557, F563, F567, F569, F57, F63, F67, F69 250 30 76 120 F225 F571, F71 F775, F779, F75, F79 273 40 76 120 308 50 108.8 120 F265 F571, F71 F775, F779, F75, F79 279 40 76 120 314 60 108.8 120 F330 F775, F779, F75, F79 317 60 108.8 120 F400 F775, F779, F781, F75, F79, F81 317 60 108.8 180 F500 F775, F779, F781, F75, F79, F81 346 70 108.8 180 F630, F800 F781, F81 510 110 108.8 180 LC1 contactors F115 F150 F185 F225 F265 F330 F400 F500 F630, F800 With LR9 relays F557, F563, F567, F569, F57, F63, F67, F69 F557, F563, F567, F569, F57, F63, F67, F69 F557, F563, F567, F569, F57, F63, F67, F69 F571, F71 F775, F779, F75, F79 F571, F71 F775, F779, F75, F79 F775, F779, F75, F79 F775, F779, F781, F75, F79, F81 F775, F779, F781, F75, F79, F81 F781, F81 (2) b H4 279 60 H2 H3 76 120 283 60 76 120 285 60 76 120 319 80 76 120 360 100 108.8 120 332 90 76 120 363 100 108.8 120 364 100 108.8 120 364 100 108.8 180 390 110 108.8 180 509 120 108.8 180 © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-61 Dimensions TeSysTM Deca Enclosed Starters and Combination Starters Refer to Catalog MKTED210011EN www.se.com/us 13 .50 TeSysTM Deca Non-Combination Starter Dimensions Table 18.139: Non-Combination Starter Dimensions [6] Non-Combination Starters A J K R E B C .75 19 .56 D/2 D Provision for 1/4" Screw F GH 14 Non-Reversing D09-32 D40-65 Reversing -- D09-32 A B C 6.77 10.04 6.25 8.66 10.83 7.21 Type 1 Type 12/3R D E F G H J K D E 5.38 9.00 11.25 0.50.75 -- 10.25 0.50.75 5.38 11.37 7.25 9.75 1.251.5 0.50.75 11.25 10.25 0.50.75 5.38 12.15 18 CONTACTORS AND STARTERS-IEC [6] All dimensions in inches. 18-62 © 2024 Schneider Electric All Rights Reserved 3/6/2024 CONTACTORS 18 AND STARTERS-IEC www.se.com/us TeSysTM K Contactors, Overload Relays and Starters Refer to Catalog MKTED210011EN Dimensions Table 18.140: TeSys K Contactor Dimensions LR2K Direct mounting under the contactor 1.38 4 x Ø4 .31 35 8 TeSysTM K Contactor Dimensions Separate mounting with LA7-K0064 terminal block on 35 mm rail (AM1DP200 or AM1DE200) 1.50 3.15 38 80 1.97 50 116 4.57 Three-phase 2.56 1.77 65 45 A H 5 3 1 96 95 98 97 6 4 2 LC1, LP1, LP4K Mini-contactors On baseplate LA1-K Test Reset/Stop 4 x Ø4 1.97 50 2.28 58 1.22 31 2.24 57 On AM1DP200 or DE200 rail (35 mm) 1.38 35 1.77 45 2.28 58 Wiring Scheme 2 1 2.95 75 3.09 (DP200) 78 3.38 (DE200) 1.77 86 45 A1 A2 96 95 14 13 A1 13 5 3 KM1 A2 14 6 4 O 97 95 98 KM1 96 95 Internal Links 96 6 4 2 LC2, LC8, LP2, LP5K Reversing mini-contactors On baseplate LA1-K 8 x Ø4 50 1.97 58 2.28 1.22 2.24 31 57 On AM1DP200 or DE200 rail (35 mm) 3.15 80 3.54 90 58 58 2.28 2.28 58 2.24 57 On printed circuit board .34 9 1.77 45 A1 2.05 52 50 1.97 2.28 58 10 x Ø.051 1.77 A2 10 x Ø1.3 45 LA2KT Electronic time delay contact blocks 27 1.06 1.34 34 1.50 38 2.24 57 3.54 90 On printed circuit board for reversing contactors or 2 mini-contactors side-by-side .34 .34 9 A1 9 52 2.05 50 1.97 2.28 A1 A2 20 x Ø.051 1.77 20 x Ø1.3 45 1.77 A2 45 On mini-contactors or reversing mini-contactors LA2-KT 2.28 58 1.34 34 2.24 57 © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-63 Dimensions TeSysTM Ultra Open Motor Starters Refer to Catalog 8502CT0201 www.se.com/us Table 18.141: TeSys Ultra Starter Dimensions Starter Controllers Rail Mounting 126 4.96 Non-Reversing [7] 126 4.96 X2 TeSysTM Ultra Starter Dimensions Screw Mounting 30 Ø4 1.18 .15 Rail Mounting Reversing Screw Mounting 29 Ø4 1.14 .15 224 8.82 120/125 4.72/4.92 233 9.17 X1 X1 154 6.06 73 2.87 163 6.42 135 45 X2 135 5.31 1.77 5.31 NOTE: Minimum electrical clearance: X1: 35 mm for Ue = 440 V; and 70 mm for Ue = 500 and 690 V X2: 0 Reversing Block for Mounting Separately from Power Base 4.53 115 113 4.45 45 1.77 Limiter Disconnector LUALB1 [7] Rail Mounting 113 4.45 45 1.77 Screw Mounting Ø4 .15 36 1.41 104 4.09 3.66 93 6.06 154 135 45 5.31 1.77 Door interlock Mechanisms LU9APN43 and LU9APN44 7.05 to 18.72 179 to 475.5 0.77 (19.6) 1.73 43.9 provision for 1/4 screws (2x) 7.3 0.29 18 CONTACTORS AND STARTERS-IEC 0.97 24.6 63.5 2.50 2.36 59.9 8.66 220.0 9.34 237.2 1.18 1.31 30.0 33.3 3.87 (98.2) [7] Maximum depth (with ModbusTM communication module) 18-64 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us Soft Starter Module ATSU01 Refer to Catalog MKTED210011EN Dimensions AltistartTM U01 and TeSysTM Ultra Soft Starters, Mounting Table 18.142: Altistart U01 and TeSys Ultra Soft Starters TeSys Ultra Combination (non-reversing power base) and ATSU01N212LT Mounting on (35 mm) rail with VW3 G4104 connector 45 1.77 TeSys Ultra Combination (non-reversing power base) and ATSU01N222LT to ATSU01N232LT Mounting on (35 mm) rail with VW3G4104 connector 45 1.77 284 11.18 150 5.91 314 12.36 170 6.69 9 0.354 TeSys Ultra Combination (non-reversing or reversing power base) and ATSU01N2206LT to ATSU01N212LT Side-by-side mounting 135 5.31 99 3.9 9 0.354 TeSys Ultra Combination (non-reversing or reversing power base) and ATSU01N222LT to ATSU01N232LT Side-by-side mounting 135 99 5.31 3.9 72.2 154 2.84 6.06 72.2 154 2.84 6.06 124 4.88 9 0.354 VW3G4104 Power Connector 9 0.354 1.83 46.6 20 44.8 0.79 1.76 CONTACTORS 18 AND STARTERS-IEC 28 1.10 0.24 6 © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-65 18 CONTACTORS AND STARTERS-IEC Dimensions TeSysTM GV Manual Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us TeSysTM Deca GV2 and GV3 Manual Starter and Protector Dimensions Table 18.143: TeSysTM Deca GV2 and GV3 Manual Starter and Protector Dimensions GV2M GV2AD, AM, AN, AU, AS, AX Block GV2AD, AM, AN Block GV2AU, AS, AX GV2AE 15 .59 Mounting of GV2M On 35 mm rail C = 78.5 mm (3.09") on AM1DP200 (35 x 7.5 mm) C = 86 mm (3.39") on AM1DE200, ED200 (35 x 15 mm) .39 10 1.77 = 45 = 3.5 89 44.5 44.5 1.75 1.75 16 44 44.5 .63 1.73 1.75 11 66 .43 2.60 GV2P = 9.3 9.3 18 .37 .37 .71 81 3.19 GV2AD, AM, AN, AU, AS, AX Block GV2AD, AM, AN Block GV2AU, AS, AX GV2AK00 14 98 .55 3.86 2.40 61 1.77 45 3.50 89 = 26 50 44.5 1.02 1.97 1.75 15 82 .59 3.23 9.3 9.3 18 .37 .37 .71 81 3.19 GV2AF4 + LAD31 Combination GV2ME + LC1D TeSys Deca range contactor Combination GV2P + LC1D TeSys Deca range contactor 44.5 1.75 GV2P + GV2GH7 for UL 508 Type E application 32 1.26 c Mounting of GV2P On 35 mm rail C = 98.5 mm (3.88") on AM1DP200 (35 x 7.5 mm) C = 106 mm (4.17") on AM1DE200, ED200 (35 x 15 mm) 44.5 44.5 1.75 1.75 84 3.31 c 13.5 .53 GV2P + GV2GH7 + LC1D TeSys Deca contactor for UL 508 Type E application 103 4.07 191 7.50 b b c1 45 c 1.77 d1 d c1 45 c 1.77 GV2ME + b c1 c d1 d LC2D09 to D18 7.4 (188.6) 3.6 (92.7) 3.9 (98.2) 3.9 (98.3) 4.1 (103.8) LC2D25 and D32 7.8 (199) 3.9 (99) 4.11 (104.5) 3.9 (98.3) 1.4 (103.8) Surface mounting enclosure GV2MC0 4 knock-outs for 16 mm plastic cable glands or no. 16 conduit. 2xØ5.3x6.3 = 44 3.6 (91.4) 1.73 3.6 (91.4) 3.8 (96.52) 3.8 (96.52) GV2P + b c1 c -- -- LC2D09 to D18 6.61 (168.1) 4.6 (116.8) 4.8 (122.3) -- -- LC2D25 and D32 7.9 (199.5) 4.6 (116.8) 4.8 (122.3) -- -- Flush mounting enclosure GV2MP0 (bracket cut-out) = b b1 5.12 130 147 5.79 84 93 = = 3.31 3.66 = 1...6 /0.04...0.24 = = 93.5 = 13 84 3.68 0.51 3.31 106.5 4.19 71 6.5 2.8 0.25 92.8 3.65 GV2 MP01, MP02 MP03, MP04 b in. mm 5.51 140 5.24 133 b1 in. mm 5.00 127 4.61 117 18-66 © 2024 Schneider Electric All Rights Reserved 3/6/2024 39 1.54 CONTACTORS 18 AND STARTERS-IEC www.se.com/us TeSysTM GV Manual Starters and Protectors Refer to Catalog MKTED210011EN Table 18.144: TeSysTM Deca GV2 and GV3 Manual Starter and Protector Dimensions (cont'd) GV2M with GK2AF01 and LC1K GV2M with GV2AF01 and LC1K GV2M with GV2AF01 and LC2K Dimensions (mm) 152 6.0 152 6.0 55 5.31 35 1.38 Dimensions Adapter Plate GK2AF01 Ø5.5 .22 45 1.77 5 .2 4.13 ± .2 105 ± 5 1.77 135 2.17 45 1.38 35 65 2.56 7 .276 79 45 3.11 1.77 Mounting external operator GV2AP0 90 3.54 Door cut-out 4xØ3.5 Ø43 0.14 1.7 24 9.5 .94 .37 GV2M on panel with GV2AF02 adapter plate 4.2 .17 54 2.13 7.5 mm height compensation plate GV1F03 50/60 1.97/2.36 2.13 54 == 1.5...5/0.06...0.20 53 min.=150 max.=290 2.1 5.91 11.42 5.2 0.21 == == 54 2.13 Sets of bus bars, GV2G445, GV2G454, GV2G472 with terminal block GV2G05 .12 l p 3 80 3.15 35 1.38 Sets of bus bars with terminal block GV1G09 13 35 0.51 1.38 Sets of bus bars GV2G245, GV2G254, GV2G272 l 30 1.2 .71 18 2.5 63 GV2G445 GV2G454 GV2G472 GV3P X1 1.8 45 0.16 x 1.8 in. (4 x 45 mm) 0.16 x 2.1 in. (4 x 54 mm) 0.16 x 1.8 in. (4 x 45 mm) I 7.0 in. (179 mm) 8.1 in. (206 mm) 10.2 in. (260 mm) Dimension P 1.8 in. (45 mm) 2.1 in. (54 mm) 2.8 in. (72 mm) GV2G245 GV2G254 GV2G272 GV2G354 (1) (2) 0.08 x 1.8 in. (2 x 45 mm) 0.08 x 2.1 in. (2 x 54 mm) 0.08 x 2.8 in.(2 x 72 mm) 0.12 x 2.1 in. (3 x 54 mm) I 3.5 in. (89 mm) 3.9 in. (98 mm) 4.6 in. (116 mm) 6.0 in. (152 mm) Mounting on rail AM1 DE200 or AM1 ED201 68 68 132 64 64 X1 136 55 X1 = Electrical clearance (ISC max) 40 mm for Ue < 500 V; 50 mm for Ue < 690 V Mounting on panel, using M4 screws 3xØ4 137,5 9 18 144 Blocks GV AN, GV AD, GV AM11 Block GV3 AU and GV3 AS Mounting on pre-slotted mounting plate AM1PA 183 AF1 EA4 137,5 16 136 37,5 136 18,7 18,7 NOTE: Leave a space of 9 mm between 2 manual motor protectors: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible: please consult your regional sales office. © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-67 Dimensions BV4 With Toggle With EverLink Connector X 103 (4.06) 116 (4.57) GV4PB With EverLink Connector X 103 165 SDx Module X 8.5 8.5 68 111 159 167 255 284 111 (4.37) 156 (6.14) (1) 171 (6.74) (2) 111 (4.37) 188 (7.41) 111 159 167 255 284 TeSysTM GV Manual Starters and Protectors Refer to Catalog MKTED210011EN TeSys Power Motor Circuit Breakers Dimensions With Crimp Lug Connector (1) (2) www.se.com/us X X X = = 81 (3.19) Y X 7 = = 81 Y 103 116 With Crimp Lug Connector (1) (2) X 103 116 Y X Y 18 CONTACTORS AND STARTERS-IEC 2.5 60 148 18 BV4 and GV4PB With Extended Rotary Handle Front extended rotary handle GV4APN01, GV4APN02, GV4APN04 2.5 X 44 208 min. / 620 max. 214 min. / 627 max. Front and side extended rotary handle, door/side panel cut-out Front and side extended rotary handle IP65, door panel cut-out 4 Ø3.5 Ø3.5 15.9 = On Trip Ø4...8 Off Reset 60 X 48 = X Ø22 15.9 = = 48 18-68 Trip 2.5 36.5 31.5 68 15.9 48.5 32.5 I X O 7 40.5 Y IP54, door/side panel cut-out Ø3.5 X Ø22 15.9 © 2024 Schneider Electric All Rights Reserved 3/6/2024 www.se.com/us TeSysTM GV Manual Starters and Protectors Refer to Catalog MKTED210011EN Table 18.145: GV5PB and GV6PB Motor Protective Circuit Breakers Circuit Breaker Frame GV5PB150 GV5PB250 GV6PB A B C 6.40 4.12 2.87 7.52 4.12 2.87 13.38 5.51 3.75 Dimensions -- Inches D 4.36 5.00 6.61 GV5PB E 0.74 1.30 2.22 GV6PB B A E G Dimensions F G 1.92 1.38 4.92 1.38 7.87 1.77 G F A F D C C B D CONTACTORS 18 AND STARTERS-IEC © 2024 Schneider Electric All Rights Reserved 3/6/2024 18-69PDFlib PDI 9.3.1p2 (C /Win64)