Report No.: BL-SZ2460066-401

TEST REPORT

Applicant: Address: Equipment Type: Model Name: Brand Name: FCC ID:
Test Standard:
Sample Arrival Date: Test Date: Date of Issue:

Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China Mobile Phone RMX3951 realme 2AUYFRMX3951
47 CFR Part 15 Subpart B
ANSI C63.4-2014
Jun. 03, 2024
Jun. 05, 2024 - Jul. 11, 2024
Jul. 11, 2024

ISSUED BY: Shenzhen BALUN Technology Co., Ltd.

Tested by: Zhang Guoxi Checked by: Liu Zhenxiang

Approved by: Liao Jianming (Technical Director)

__________________ ___________________

__________________

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 1 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

Version
Rev. 01 Rev. 02

Revision History

Issue Date
Jul. 04, 2024 Jul. 11, 2024

Revisions
Initial Issue Chapter 4.2, add testing mode Update report homepage testing time

TABLE OF CONTENTS

1 GENERAL INFORMATION........................................................................................................ 4

1.1

Test Laboratory ............................................................................................................ 4

1.2

Test Location ................................................................................................................ 4

2 PRODUCT INFORMATION ....................................................................................................... 5

2.1

Applicant Information .................................................................................................... 5

2.2

Manufacturer Information.............................................................................................. 5

2.3

General Description for Equipment under Test (EUT) ................................................... 5

2.4

Ancillary Equipment ...................................................................................................... 5

2.5

Technical Information ................................................................................................... 7

3 SUMMARY OF TEST RESULTS ............................................................................................... 8

3.1

Test Standards ............................................................................................................. 8

3.2

Verdict .......................................................................................................................... 8

3.3

Test Uncertainty ........................................................................................................... 8

4 GENERAL TEST CONFIGURATIONS ...................................................................................... 9

4.1

Test Enclosure List ....................................................................................................... 9

4.2

Test Configurations .................................................................................................... 10

4.3

Test Setups ................................................................................................................ 12

5 TEST ITEMS ........................................................................................................................... 14

5.1

Emission Tests ........................................................................................................... 14

ANNEX A TEST RESULTS ......................................................................................................... 19

A.1

Radiated Emission...................................................................................................... 19

A.2

Conducted Emission, AC Ports................................................................................... 30

ANNEX B TEST SETUP PHOTOS ............................................................................................. 36

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 2 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 ANNEX C EUT EXTERNAL PHOTOS......................................................................................... 36 ANNEX D EUT INTERNAL PHOTOS.......................................................................................... 36

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 3 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

1 GENERAL INFORMATION

1.1 Test Laboratory

Name Address Phone Number

Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China +86 755 6685 0100

1.2 Test Location

Name Location Accreditation Certificate

Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi
Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park,
No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China The laboratory is a testing organization accredited by FCC as a accredited testing laboratory. The designation number is CN1196.

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 4 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

2 PRODUCT INFORMATION

2.1 Applicant Information

Applicant Address

Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China

2.2 Manufacturer Information

Manufacturer Address

Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China

2.3 General Description for Equipment under Test (EUT)

EUT Name Model Name Under Test Series Model Name Description of Model name differentiation Hardware Version Software Version Dimensions (Approx.) Weight (Approx.) EUT ID IMEI Number

Mobile Phone RMX3951 N/A
N/A
11 realme UI 5.0 about 165.6×76.1×7.79(mm) about 190g S31 IMEI1: 862456070025433, IMEI2:862456070025425

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 5 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

2.4 Ancillary Equipment

Ancillary Equipment 1
Ancillary Equipment 2 Ancillary Equipment 3 Ancillary Equipment 4

Battery Brand Name Model No. Serial No. Capacity Rated Voltage Limit Charge Voltage
Manufacturer
Adapter 1 Brand Name Model No. Serial No. Rated Input Rated Output Manufacturer Adapter 2 Brand Name Model No. Serial No. Rated Input Rated Output Manufacturer USB Cable Length (Approx.)

SUPERVOOC BLPA17 N/A 5000 mAh/19.45 Wh 3.89 V 4.48 V Shenzhen Sunwoda Intelligence Technology Co., Ltd.
SUPERVOOC VCB4JAUH N/A 100-240V~, 50/60Hz, 1.5A 5.0V 2.0A or 5-11V 4.1A MAX Chenyang
SUPERVOOC VCB4JAUH N/A 100-240V~, 50/60Hz, 1.5A 5.0V 2.0A or 5-11V 4.1A MAX GOLDEN LAKE
1.0 m

Note: All adapters are tested, only the worst data of VCB4JAUH (Chenyang) shown in this report.

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 6 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

2.5 Technical Information

Network and Wireless connectivity
Classification of equipment The highest internal frequency of EUT

2G Network GSM/GPRS/EDGE 850/1900 MHz 3G Network WCDMA/HSDPA/HSUPA/HSPA+ Band 2/4/5 4G Network LTE FDD Band 2/4/5/7/12/13/17/26/66
LTE TDD Band 38/41 LTE CA Uplink (UL): CA_7C, CA_38C, CA_41C LTE Downlink (DL): CA_2C, CA_7B, CA_7C, CA_38C, CA_41C, CA_41A-41A, CA_7A-7A, CA_2A-38A, CA_5A-41A, CA_5A-66A, CA_7A-66A, CA_2A-2A, CA_2A-5A, CA_2A-7A, CA_2A-12A, CA_4A-5A, CA_4A-7A, CA_5A-7A, CA_12A-66A, CA_66A-66A, CA_4A-4A, CA_26A-41A, CA_5A-38A, CA_2A-4A, CA_38A-66A, CA_26A-38A, CA_2A-66A, CA_7A-26A 5G Network SA: NR n5/n7/n38/n41/n66 NSA UL (EN-DC): DC_7A_n5A, DC_66A_n5A, DC_2A_n7A, DC_4A_n7A, DC_5A_n7A, DC_7A_n7A, DC_66A_n7A, DC_2A_n66A, DC_5A_n66A, DC_7A_n66A, DC_66A_n66A, DC_2A_n38A, DC_4A_n38A, DC_5A_n38A, DC_38A_n38A, DC_66A_n38A, DC_2A_n41A, DC_4A_n41A, DC_26A_n41A, DC_41A_n41A, DC_66A_n41A DL(EN-DC): DC_7C_n5A, DC_7C_n66A, DC_5A-66A_n66A, DC_7A-66A_n66A, DC_2A-5A_n66A, DC_5A-7A_n7A, DC_5A7A_n66A, DC_66A-66A_n5A, DC_66A-66A_n7A NR CA Downlink (DL): CA_n5A-n7A, CA_n7B Bluetooth (BR+EDR+BLE) 2.4G WIFI 802.11b, 802.11g, 802.11n(HT20/40) and VHT(20/40) 5G WIFI 802.11a, 802.11n(HT20/40) and 802.11ac(VHT20/40/80) U-NII-1/2A/2C/3, GPS, GLONASS, BDS, Galileo, NFC
Class B
5850 MHz

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 7 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

3 SUMMARY OF TEST RESULTS

3.1 Test Standards

No.

Identity

Document Title

1 47 CFR Part 15 Subpart B Unintentional Radiators

American National Standard for Methods of

Measurement of Radio-Noise Emissions from Low-

2

ANSI C63.4-2014

Voltage Electrical and Electronic Equipment in the

Range of 9 kHz to 40 GHz

3.2 Verdict

No.

Description

1

Radiated Emission

2 Conducted Emission, AC Ports

FCC Rule 15.109 15.107

Test Verdict Pass Pass

Remark ---

3.3 Test Uncertainty

The following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Measurement Conducted emissions (9 kHz-30 MHz) Radiated emissions (30 MHz-1 GHz)-966#2 Radiated emissions (1 GHz-18 GHz)-966#2

Value 3.2 dB 4.4 dB 5.0 dB

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 8 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

4 GENERAL TEST CONFIGURATIONS

4.1 Test Enclosure List

Description Wireless
Communications Test Set

Manufacturer R&S

Laptop

Lenovo

Laptop Data connector
USB disk

HONOR UGREEN Sandisk

TF Card

SAMSUNG

Headset Type-C Headset

OPPO OPPO

Model
CMW500
ThinkPad E495 N/A 40702
DTMC3G2 MB-
MD256KA MH156 MH156

Serial No.
102318
N/A N/A N/A N/A N/A N/A N/A

Length Description Use

N/A

Cal. Due



2025.05.08

N/A

N/A



N/A

N/A



N/A

N/A



N/A

64G



N/A

256G



1.12m

N/A



1.12m

N/A



Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 9 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

4.2 Test Configurations

All test modes of EUT are listed in the table below.

Test Mode Configuration

Description

Mode 1

The GSM 850 MHz RX Test Mode GSM 850 MHz RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 2

The EGPRS 850 MHz RX Test Mode EGPRS 850 MHz RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 3

The WCDMA Band 5 RX Test Mode WCDMA Band 5 RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 4

The FDD LTE Band 5 RX Test Mode LTE Band 5 RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 5

The FDD LTE Band 12 RX Test Mode LTE Band 12 RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 6

The FDD LTE Band 13 RX Test Mode LTE Band 13 RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 7

The FDD LTE Band 17 RX Test Mode LTE Band 17 RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 8

The FDD LTE Band 26 RX Test Mode LTE Band 26 RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 9

The n5 Test Mode RX Test Mode n5 RX + EUT +Adapter + USB Cable + Battery + Headset

Mode 10

The Standby Test Mode EUT + Adapter + USB Cable + Battery + Headset

Mode 11

The Front Camera Test Mode EUT + Adapter + USB Cable + Battery + Headset

Mode 12

The Rear Camera Test Mode EUT + Adapter + USB Cable + Battery + Headset

Mode 13

The Video Play Test Mode EUT + Adapter + USB Cable + Battery + Headset

Mode 14

The USB Test Mode EUT + USB Cable + Battery + Laptop + Headset

Mode 15

The OTG Test Mode EUT + Battery + Data connector + USB Disk

Mode 16

The Type-C Headset Test Mode EUT + Type-C Headset + Battery

Test Case Radiated Emission

Test Mode Configuration Mode 1~Mode 16

Worst Mode 11, 14

Conducted Emission, AC Ports

Mode 1~Mode 14

12, 14

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 10 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

Test Case

Test Mode Configuration

Worst Mode

Note: All operation modes were tested, but only test data of the worst mode was presented in this

report.

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 11 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401
4.3 Test Setups
Test Setup 1
Radiated Emission (30 MHz-1 GHz)

Radiated Emission (above 1 GHz)

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 12 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 Test Setup 2
Conducted Emissions, AC Ports

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 13 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

5 TEST ITEMS

5.1 Emission Tests

5.1.1 Radiated Emission 5.1.1.1 Limit

Frequency range (MHz)

Class B (at 3 m)

Field Strength

Field Strength

(µV/m)

(dBµV/m)

30 - 88

100

40

88 - 216

150

43.5

216 - 960

200

46

Above 960

500

54

NOTE:

1) Field Strength (dBµV/m) = 20*log [Field Strength (µV/m)].

2) In the emission tables above, the tighter limit applies at the band edges.

3) For 30 MHz to 1000 MHz, the CISPR quasi-peak is employed.

Class A (at 3 m) Field Strength
(dBµV/m) 49.5 54 56.9 60

For above 1000 MHz, according to the requirements of FCC 15.35, unless otherwise specified, the limit

on peak radio frequency emissions is 20 dB above the maximum permitted average emission limit

applicable to the equipment under test.

Frequency range (GHz)

Class B (at 3 m)

Field Strength (µV/m)

Field Strength Average (dBµV/m)

Field Strength Peak
(dBµV/m)

Class A (at 3 m)

Field Strength Field Strength

Average

Peak

(dBµV/m)

(dBµV/m)

1 - FM

500

54

74

60

80

Note 1: The highest measurement frequency, FM, in GHz, shall be determined as next Table. Note 2: Average Class A limit at 3m L3m is determined by the following conversion formula: L3m =L10m + 20*log(d10m/d3m) Where:

L3m is Average Class A limit at 3m;

L10m is Average Class A limit at 10m; d10m is Measurement distance in 10m; d3m is Measurement distance in 3m. For this case: L3m = 49.5 + 20*log(10/3)=60 (dBµV/m).

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 14 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

Highest internal frequency (FX)

Highest measurement frequency (FM)

FX  108 MHz

1 GHz

108 MHz  FX  500 MHz

2 GHz

500 MHz  FX  1 GHz

5 GHz

FX  1 GHz

5 *FX or 40 GHz, whichever is lower.

Note: FX is Highest frequency generated or used in the device or on which the device operates or

tunes.

5.1.1.2 Test Setup

Refer to 4.3 section (test setup 1) for radiated emission test, the photo of test setup please refer to ANNEX B.

5.1.1.3 Test Procedure

All Radiated Emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report.

An initial pre-scan was performed in the chamber using the EMI Receiver in peak detection mode. Quasi-peak measurements were conducted based on the peak sweep graph. The EUT was measured by Bi-Log antenna with 2 orthogonal polarities.

The measurement frequency range is from 30 MHz to the 5th harmonic of the maximum frequency of the EUT internal source. The Turn Table is actuated to turn from 0°to 360°, and both horizontal and vertical polarizations of the Test Antenna are used to find the maximum radiated power. Mid channels on all channel bandwidth verified. Only the worst RB size/offset presented.

Use the following spectrum analyzer settings:

Span = wide enough to fully capture the emission being measured

RBW = 1 MHz for f  1 GHz, 100 kHz for f < 1 GHz

VBW  RBW

Sweep = auto

Detector function = peak for f <1 GHz, peak & RMS Average for f  1 GHz

Trace = max hold

5.1.1.4 Test Result and Test Equipment List

Please refer to ANNEX A.1.

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 15 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401
NOTE: 1. Results (dBµV/m) = Reading (dBµV) + Factor (dB/m) The reading level is calculated by software which is not shown in the sheet 2. Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) ­ Amplifier Gain (dB) 3. Margin = Limit - Results

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 16 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401
5.1.2 Conducted Emission, AC Ports 5.1.2.1 Test Limit

Frequency range (MHz)
0.15 - 0.50 0.50 - 30

Quasi-peak (dBµV) 79 73

Class A

Average (dBµV)
66 60

Class B

Frequency range (MHz)

Quasi-peak

Average

(dBµV)

(dBµV)

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

NOTE:

1) The lower limit shall apply at the band edges.

2) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50 MHz.

5.1.2.2 Test Setup

Refer to 4.3 section test (test setup 2) for conducted emission, the photo of test setup please refer to ANNEX B.

5.1.2.3 Test Procedure

The EUT is connected to the power mains through a LISN which provides 50 /50 µH of coupling impedance for the measuring instrument. The test frequency range is from 150 kHz to 30 MHz. The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average (AV) detectors; the emission levels that are more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed.

Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz) for which the device is capable of operation. A device rated for 50/60 Hz operation need not be tested at both frequencies provided the radiated and line conducted emissions are the same at both frequencies.

Use the following spectrum analyzer settings:

RBW = 9 kHz

VBW  RBW

Sweep = 10ms

Detector function =peak & Average

Trace = max hold

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 17 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401
5.1.2.4 Test Result and Test Equipment List
Please refer to ANNEX A.2. NOTE: 1. Results (dBµV) = Reading (dBµV) + Factor (dB) The reading level is calculated by software which is not shown in the sheet 2. Factor = Insertion loss + Cable loss 3. Margin = Limit - Results

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 18 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401
ANNEX A TEST RESULTS
A.1 Radiated Emission
Note 1: The symbol of "--" in the table which means not application. Note 2: For the test data above 1 GHz, according the ANSI C63.4-2014, where limits are specified for both average and peak (or quasi-peak) detector functions, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an average measurement. Note 3: The Radiated Emission is required to be investigated to the upper frequency of 5th harmonic of the highest internal frequency of EUT or 40 GHz, whichever is lower. The test results above 18GHz are only noise and are not recorded in the report.

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 19 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

Sample No. Humidity Test Engineer

S31 53%RH He Shichang

Test Mode 11

1) Test Antenna Vertical, 30 MHz ­ 1 GHz

Temperature Pressure Test Date

21.2 101kPa 2024.06.05

No. Frequency Results

(MHz)

(dBuV/m)

1

30.611

37.40

1* 30.611

33.72

2

36.208

29.31

3

58.373

25.07

4

81.168

29.17

5

265.613

27.34

6

904.891

34.77

Factor (dB) -28.11 -28.11 -26.89 -25.59 -29.51 -21.79 -4.49

Limit (dBuV/m) 40.0 40.0 40.0 40.0 40.0 46.0 46.0

Margin (dB) 2.60 6.28 10.69 14.93 10.83 18.66 11.23

Detector
Peak QP Peak Peak Peak Peak Peak

Table (Degree) 121.00 121.00 138.00 66.00 63.00 4.00 300.00

Height (cm) 101 101 100 100 100 200 200

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
N/A Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 20 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 2) Test Antenna Horizontal, 30 MHz ­ 1 GHz

No. Frequency Results

(MHz)

(dBuV/m)

1

30.922

24.51

2

148.583

25.77

3

289.863

30.26

4

313.871

28.39

5

357.909

27.14

6

962.218

36.69

Factor (dB) -28.17 -28.30 -20.88 -20.25 -18.71 -3.52

Limit (dBuV/m) 40.0 43.5 46.0 46.0 46.0 54.0

Margin (dB) 15.49 17.73 15.74 17.61 18.86 17.31

Detector
Peak Peak Peak Peak Peak Peak

Table (Degree) 43.00 160.00 101.00 120.00 360.00 213.00

Height (cm) 200 200 100 100 100 200

Antenna

Verdict

Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Pass Pass Pass Pass Pass Pass

Equipment Information

Equipment Name Supplier

Model

Serial No. Cal. Date Cal. Due Use

Frequency Below 1 GHz

EMI Receiver
Amplifier (30-1GHz) Test Antenna-
Bi-Log Anechoic Chamber#2

Keysight
COM-MV SCHWARZB
ECK YiHeng

N9038A ZT30-1000M VULB 9168 9m*6m*6m

MY55330120 2023.09.05 2024.09.04 B2017119081 2023.12.05 2024.12.04

9168-00867 2022.04.12 2025.04.11

142

2021.08.19 2024.08.18

Description

Supplier

Name

Version

/

Use

Test Software

BALUN

BL410-E

V22.930

/

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 21 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 3) Test Antenna Vertical, 1 GHz ­ 18 GHz

No. Frequency Results

(MHz)

(dBuV/m)

1

1242.000 38.59

1** 1242.000 29.31

2

1530.500 40.16

2** 1530.500 29.70

3

4991.250 54.28

3** 4991.250 45.50

4

5754.750 56.23

4** 5754.750 46.93

5

6960.500 55.77

5** 6960.500 44.76

6

14042.000 56.50

6** 14042.000 45.87

Factor (dB) -16.24 -16.24 -16.00 -16.00 2.11 2.11 3.38 3.38 1.30 1.30 5.08 5.08

Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB) 35.41 24.69 33.84 24.30 19.72 8.50 17.77 7.07 18.23 9.24 17.50 8.13

Detector
Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV

Table (Degree) 301.00 301.00 123.00 123.00 281.00 281.00 0.00 0.00 226.00 226.00 50.00 50.00

Height (cm) 100 100 100 100 100 100 100 100 100 100 100 100

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 22 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 4) Test Antenna Horizontal, 1 GHz ­ 18 GHz

No. Frequency Results

(MHz)

(dBuV/m)

1

1326.900 39.33

1** 1326.900 30.74

2

2025.400 42.81

2** 2025.400 33.51

3

4299.000 51.78

3** 4299.000 41.78

4

6394.250 55.28

4** 6394.250 45.08

5

10057.500 53.81

5** 10057.500 43.84

6

13370.500 56.22

6** 13370.500 47.23

Factor (dB) -16.03 -16.03 -13.47 -13.47 -0.28 -0.28 1.84 1.84 2.44 2.44 5.10 5.10

Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB) 34.67 23.26 31.19 20.49 22.22 12.22 18.72 8.92 20.19 10.16 17.78 6.77

Detector
Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV

Table (Degree) 127.00 127.00 52.00 52.00 43.00 43.00 153.00 153.00 179.00 179.00 245.00 245.00

Height (cm) 100 100 100 100 100 100 100 100 100 100 100 100

Antenna

Verdict

Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 23 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

Equipment Information

Equipment Name Supplier

Model

Serial No. Cal. Date Cal. Due Use

Frequency Above 1 GHz

EMI Receiver
Amplifier (1-12GHz) Amplifier 0.8-21GHz
Test AntennaHorn
Anechoic Chamber#2

Keysight Advanced Microwave
Mini-Circuits
SCHWARZB ECK
YiHeng

N9038A WLA652A ZVA-213-S+ BBHA 9120D 9m*6m*6m

MY55330120 2023.09.05 2024.09.04 1740103 2023.12.05 2024.12.04

225321316 2023.12.05 2024.12.04

01917

2022.06.09 2025.06.08

142

2021.08.19 2024.08.18

Description

Supplier

Name

Version

/

Use

Test Software

BALUN

BL410-E

V22.930

/

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 24 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 Test Mode 14 5) Test Antenna Vertical, 30 MHz ­ 1 GHz

No. Frequency Results

(MHz)

(dBuV/m)

1

44.869

42.70

1* 44.869*

33.99

2

87.133

27.37

3

280.890

30.33

4

399.813

34.80

5

451.077

35.79

6

572.230

34.96

Factor (dB) -25.66 -25.66 -29.37 -24.12 -20.95 -19.86 -16.98

Limit (dBuV/m) 40.0 40.0 40.0 46.0 46.0 46.0 46.0

Margin (dB) -2.70 6.01 12.63 15.67 11.20 10.21 11.04

Detector
Peak QP Peak Peak Peak Peak Peak

Table (Degree) 249.00 249.00 188.00 299.00 205.00 153.00 290.00

Height (cm) 106 106 100 200 100 100 100

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
N/A Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 25 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 6) Test Antenna Horizontal, 30 MHz ­ 1 GHz

No. Frequency Results

(MHz)

(dBuV/m)

1

44.682

40.57

1* 44.682*

33.78

2

133.354

29.62

3

166.139

26.90

4

232.536

32.76

5

270.948

34.59

6

399.716

34.49

Factor (dB) -25.59 -25.59 -30.02 -29.30 -25.43 -24.40 -20.95

Limit (dBuV/m) 40.0 40.0 43.5 43.5 46.0 46.0 46.0

Margin (dB) -0.57 6.22 13.88 16.60 13.24 11.41 11.51

Detector
Peak QP Peak Peak Peak Peak Peak

Table (Degree) 209.00 209.00 271.00 225.00 236.00 252.00 212.00

Height (cm) 198 198 200 200 100 100 100

Antenna

Verdict

Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

N/A Pass Pass Pass Pass Pass Pass

Equipment Information

Equipment Name Supplier

Model

Serial No. Cal. Date Cal. Due Use

Frequency Below 1 GHz

EMI Receiver
Amplifier (30-1GHz) Test Antenna-
Bi-Log Anechoic Chamber#2

Keysight
COM-MV SCHWARZB
ECK YiHeng

N9038A ZT30-1000M VULB 9168 9m*6m*6m

MY55330120 2023.09.05 2024.09.04 B2017119081 2023.12.05 2024.12.04

9168-00867 2022.04.12 2025.04.11

142

2021.08.19 2024.08.18

Description

Supplier

Name

Version

/

Use

Test Software

BALUN

BL410-E

V22.930

/

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 26 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 7) Test Antenna Vertical, 1 GHz ­ 18 GHz

No. Frequency Results

(MHz)

(dBuV/m)

1

1199.600 49.27

1** 1199.600 39.04

2

2794.200 52.26

2** 2794.200 40.01

3

4198.750 51.08

3** 4198.750 41.92

4

7721.500 56.44

4** 7721.500 45.66

5

11956.500 54.84

5** 11956.500 45.43

6

13647.000 56.26

6** 13647.000 46.87

Factor (dB) -16.22 -16.22 -8.39 -8.39 -0.30 -0.30 2.24 2.24 2.64 2.64 5.11 5.11

Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB) 24.73 14.96 21.74 13.99 22.92 12.08 17.56 8.34 19.16 8.57 17.74 7.13

Detector
Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV

Table (Degree) 232.00 232.00 156.00 156.00 300.00 300.00 53.00 53.00 360.00 360.00 34.00 34.00

Height (cm) 100 100 100 100 100 100 100 100 100 100 100 100

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 27 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 8) Test Antenna Horizontal, 1 GHz ­ 18 GHz

No. Frequency Results

(MHz)

(dBuV/m)

1

1199.900 49.55

1** 1199.900 39.63

2

2800.300 51.30

2** 2800.300 36.75

3

3925.250 51.13

3** 3925.250 39.71

4

5070.250 54.84

4** 5070.250 44.59

5

7932.750 56.71

5** 7932.750 46.00

6

13570.500 57.41

6** 13570.500 46.66

Factor (dB) -16.21 -16.21 -8.13 -8.13 -1.66 -1.66 1.58 1.58 3.15 3.15 4.73 4.73

Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB) 24.45 14.37 22.70 17.25 22.87 14.29 19.16 9.41 17.29 8.00 16.59 7.34

Detector
Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV

Table (Degree) 223.00 223.00 164.00 164.00 119.00 119.00 263.00 263.00 209.00 209.00 170.00 170.00

Height (cm) 100 100 100 100 100 100 100 100 100 100 100 100

Antenna

Verdict

Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 28 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

Equipment Information

Equipment Name Supplier

Model

Serial No. Cal. Date Cal. Due Use

Frequency Above 1 GHz

EMI Receiver
Amplifier (1-12GHz) Amplifier 0.8-21GHz
Test AntennaHorn
Anechoic Chamber#2

Keysight Advanced Microwave
Mini-Circuits
SCHWARZB ECK
YiHeng

N9038A WLA652A ZVA-213-S+ BBHA 9120D 9m*6m*6m

MY55330120 2023.09.05 2024.09.04 1740103 2023.12.05 2024.12.04

225321316 2023.12.05 2024.12.04

01917

2022.06.09 2025.06.08

142

2021.08.19 2024.08.18

Description

Supplier

Name

Version

/

Use

Test Software

BALUN

BL410-E

V22.930

/

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 29 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401
A.2 Conducted Emission, AC Ports
Note 1: Measurements shall be made with a quasi-peak measuring receiver in the frequency range 0.15MHz to 30 MHz. To reduce the testing time, a peak measuring receiver may be used instead of a quasi-peak measuring receiver. In case of dispute, measurement with a quasi-peak measuring receiver will take precedence.
Note 2: Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz) for which the device is capable of operation. So, The configuration 120 VAC, 60 Hz and 240 VAC, 50 Hz were tested respectively, but only the worst configuration (120 VAC, 60 Hz ) shown here.

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 30 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

Sample No. Humidity Test Engineer

S31 54%RH Yang Yang

Test Mode 12

1) AC Ports - L Phase

Temperature Pressure Test Date

22.1 101kPa 2024.06.04

No. Frequency Results

(MHz)

(dBuV)

1

0.164

39.59

1** 0.164

32.70

2

0.286

43.36

2** 0.286

27.86

3

0.408

41.18

3** 0.408

29.61

4

1.394

38.33

4** 1.394

21.60

5

5.880

41.74

5** 5.880

32.82

6

22.880

43.93

6** 22.880

34.64

Factor (dB) 10.09 10.09 10.06 10.06 10.64 10.64 10.85 10.85 10.96 10.96 13.24 13.24

Limit (dBuV) 65.26 55.26 60.64 50.64 57.69 47.69 56.00 46.00 60.00 50.00 60.00 50.00

Margin (dB) 25.67 22.56 17.28 22.78 16.51 18.08 17.67 24.40 18.26 17.18 16.07 15.36

Detector Line

Peak

L

AV

L

Peak

L

AV

L

Peak

L

AV

L

Peak

L

AV

L

Peak

L

AV

L

Peak

L

AV

L

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 31 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 2) AC Ports - N Phase

No. Frequency Results

(MHz)

(dBuV)

1

0.150

42.09

1** 0.150

36.68

2

0.296

45.30

2** 0.296

35.06

3

0.444

42.30

3** 0.444

31.94

4

3.962

43.09

4** 3.962

29.76

5

5.876

43.30

5** 5.876

32.57

6

21.658

45.10

6** 21.658

35.84

Factor (dB) 10.11 10.11 10.07 10.07 10.59 10.59 10.62 10.62 10.92 10.92 13.47 13.47

Limit (dBuV) 66.00 56.00 60.35 50.35 56.99 46.99 56.00 46.00 60.00 50.00 60.00 50.00

Margin (dB) 23.91 19.32 15.05 15.29 14.69 15.05 12.91 16.24 16.70 17.43 14.90 14.16

Detector Line

Peak

N

AV

N

Peak

N

AV

N

Peak

N

AV

N

Peak

N

AV

N

Peak

N

AV

N

Peak

N

AV

N

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 32 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 Test Mode 14 3) AC Ports - L Phase

No. Frequency Results

(MHz)

(dBuV)

1

0.150

63.04

1*

0.150

59.72

1** 0.150

42.16

2

0.182

55.84

2** 0.182

37.23

3

0.420

45.29

3** 0.420

32.06

4

4.744

37.37

4** 4.744

27.51

5

15.334

36.39

5** 15.334

23.78

6

22.478

37.25

6** 22.478

27.37

Factor (dB) 10.11 10.11 10.11 10.07 10.07 10.62 10.62 10.79 10.79 12.71 12.71 13.36 13.36

Limit (dBuV) 66.00 66.00 56.00 64.39 54.39 57.45 47.45 56.00 46.00 60.00 50.00 60.00 50.00

Margin (dB) 2.96 6.28 13.84 8.55 17.16 12.16 15.39 18.63 18.49 23.61 26.22 22.75 22.63

Detector Line

Peak

L

QP

L

AV

L

Peak

L

AV

L

Peak

L

AV

L

Peak

L

AV

L

Peak

L

AV

L

Peak

L

AV

L

Verdict
N/A Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 33 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401 4) AC Ports - N Phase

No. Frequency Results

(MHz)

(dBuV)

1

0.150

62.58

1*

0.150

58.92

1** 0.150

44.77

2

0.158

61.01

2*

0.158

57.42

2** 0.158

37.22

3

0.400

46.55

3** 0.400

30.81

4

1.218

37.60

4** 1.218

23.64

5

15.502

36.30

5** 15.502

20.44

6

22.206

36.54

6** 22.206

22.95

Factor (dB) 10.11 10.11 10.11 10.10 10.10 10.10 10.65 10.65 10.47 10.47 12.71 12.71 13.24 13.24

Limit (dBuV) 66.00 66.00 56.00 65.57 65.57 55.57 57.85 47.85 56.00 46.00 60.00 50.00 60.00 50.00

Margin (dB) 3.42 7.08 11.23 4.56 8.15 18.35 11.30 17.04 18.40 22.36 23.70 29.56 23.46 27.05

Detector Line

Peak

N

QP

N

AV

N

Peak

N

QP

N

AV

N

Peak

N

AV

N

Peak

N

AV

N

Peak

N

AV

N

Peak

N

AV

N

Verdict
N/A Pass Pass N/A Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 34 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401

Equipment Information

Equipment Name Supplier

Model

Serial No. Cal. Date Cal. Due Use

EMI Receiver LISN ISN

KEYSIGHT SCHWARZB
ECK TESEQ

N9010B NSLK 8127 ISN T800

MY57110309 8127-687 34449

2023.09.05 2024.09.04 2024.05.09 2025.05.08 2023.11.10 2024.11.09

ISN Shielded Room
Description

TESEQ
YiHeng Electronic Co., Ltd
Supplier

ISN T8-Cat6
3.5m*3.1m*2. 8m
Name

53561 112
Version

2024.04.24 2025.04.23

2022.02.19 2025.02.18

/

Use

Test Software

BALUN

BL410-E

V22.930

/

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 35 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401
ANNEX B TEST SETUP PHOTOS
Please refer the document "BL-SZ2460066-AE-1.PDF".
ANNEX C EUT EXTERNAL PHOTOS
Please refer the document "BL-SZ2460066-AW.PDF".
ANNEX D EUT INTERNAL PHOTOS
Please refer the document "BL-SZ2460066-AI.PDF".

Tel: +86-755-66850100

E-mail: qc@baluntek.com

Page No. 36 / 37

Web: www.titcgroup.com

Template No.: TRP-FCC 15B (2023-07-01)

Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China

Report No.: BL-SZ2460066-401
Statement
1. The laboratory guarantees the scientificity, accuracy and impartiality of the test, and is responsible for all the information in the report, except the information provided by the customer. The customer is responsible for the impact of the information provided on the validity of the results. 2. The report without China inspection body and laboratory Mandatory Approval (CMA) mark has no effect of proving to the society. 3. For the report with CNAS mark or A2LA mark, the items marked with "" are not within the accredited scope. 4. This report is invalid if it is altered, without the signature of the testing and approval personnel, or without the "inspection and testing dedicated stamp" or test report stamp. 5. The test data and results are only valid for the tested samples provided by the customer. 6. This report shall not be partially reproduced without the written permission of the laboratory. 7. Any objection shall be raised to the laboratory within 30 days after receiving the report.
--END OF REPORT--