Realme Chongqing Mobile Telecommunications Corp., Ltd. RMX3951 Mobile Phone 2AUYFRMX3951 2AUYFRMX3951 rmx3951
Realme Chongqing Mobile Telecommunications Corp., Ltd. RMX3951 2AUYFRMX3951 2AUYFRMX3951 rmx3951
Report No.: BL-SZ2460066-401 TEST REPORT Applicant: Address: Equipment Type: Model Name: Brand Name: FCC ID: Test Standard: Sample Arrival Date: Test Date: Date of Issue: Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China Mobile Phone RMX3951 realme 2AUYFRMX3951 47 CFR Part 15 Subpart B ANSI C63.4-2014 Jun. 03, 2024 Jun. 05, 2024 - Jul. 11, 2024 Jul. 11, 2024 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Zhang Guoxi Checked by: Liu Zhenxiang Approved by: Liao Jianming (Technical Director) __________________ ___________________ __________________ Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 1 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Version Rev. 01 Rev. 02 Revision History Issue Date Jul. 04, 2024 Jul. 11, 2024 Revisions Initial Issue Chapter 4.2, add testing mode Update report homepage testing time TABLE OF CONTENTS 1 GENERAL INFORMATION........................................................................................................ 4 1.1 Test Laboratory ............................................................................................................ 4 1.2 Test Location ................................................................................................................ 4 2 PRODUCT INFORMATION ....................................................................................................... 5 2.1 Applicant Information .................................................................................................... 5 2.2 Manufacturer Information.............................................................................................. 5 2.3 General Description for Equipment under Test (EUT) ................................................... 5 2.4 Ancillary Equipment ...................................................................................................... 5 2.5 Technical Information ................................................................................................... 7 3 SUMMARY OF TEST RESULTS ............................................................................................... 8 3.1 Test Standards ............................................................................................................. 8 3.2 Verdict .......................................................................................................................... 8 3.3 Test Uncertainty ........................................................................................................... 8 4 GENERAL TEST CONFIGURATIONS ...................................................................................... 9 4.1 Test Enclosure List ....................................................................................................... 9 4.2 Test Configurations .................................................................................................... 10 4.3 Test Setups ................................................................................................................ 12 5 TEST ITEMS ........................................................................................................................... 14 5.1 Emission Tests ........................................................................................................... 14 ANNEX A TEST RESULTS ......................................................................................................... 19 A.1 Radiated Emission...................................................................................................... 19 A.2 Conducted Emission, AC Ports................................................................................... 30 ANNEX B TEST SETUP PHOTOS ............................................................................................. 36 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 2 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 ANNEX C EUT EXTERNAL PHOTOS......................................................................................... 36 ANNEX D EUT INTERNAL PHOTOS.......................................................................................... 36 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 3 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 1 GENERAL INFORMATION 1.1 Test Laboratory Name Address Phone Number Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China +86 755 6685 0100 1.2 Test Location Name Location Accreditation Certificate Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China The laboratory is a testing organization accredited by FCC as a accredited testing laboratory. The designation number is CN1196. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 4 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Address Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China 2.2 Manufacturer Information Manufacturer Address Realme Chongqing Mobile Telecommunications Corp., Ltd. No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China 2.3 General Description for Equipment under Test (EUT) EUT Name Model Name Under Test Series Model Name Description of Model name differentiation Hardware Version Software Version Dimensions (Approx.) Weight (Approx.) EUT ID IMEI Number Mobile Phone RMX3951 N/A N/A 11 realme UI 5.0 about 165.6×76.1×7.79(mm) about 190g S31 IMEI1: 862456070025433, IMEI2:862456070025425 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 5 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 2.4 Ancillary Equipment Ancillary Equipment 1 Ancillary Equipment 2 Ancillary Equipment 3 Ancillary Equipment 4 Battery Brand Name Model No. Serial No. Capacity Rated Voltage Limit Charge Voltage Manufacturer Adapter 1 Brand Name Model No. Serial No. Rated Input Rated Output Manufacturer Adapter 2 Brand Name Model No. Serial No. Rated Input Rated Output Manufacturer USB Cable Length (Approx.) SUPERVOOC BLPA17 N/A 5000 mAh/19.45 Wh 3.89 V 4.48 V Shenzhen Sunwoda Intelligence Technology Co., Ltd. SUPERVOOC VCB4JAUH N/A 100-240V~, 50/60Hz, 1.5A 5.0V 2.0A or 5-11V 4.1A MAX Chenyang SUPERVOOC VCB4JAUH N/A 100-240V~, 50/60Hz, 1.5A 5.0V 2.0A or 5-11V 4.1A MAX GOLDEN LAKE 1.0 m Note: All adapters are tested, only the worst data of VCB4JAUH (Chenyang) shown in this report. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 6 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 2.5 Technical Information Network and Wireless connectivity Classification of equipment The highest internal frequency of EUT 2G Network GSM/GPRS/EDGE 850/1900 MHz 3G Network WCDMA/HSDPA/HSUPA/HSPA+ Band 2/4/5 4G Network LTE FDD Band 2/4/5/7/12/13/17/26/66 LTE TDD Band 38/41 LTE CA Uplink (UL): CA_7C, CA_38C, CA_41C LTE Downlink (DL): CA_2C, CA_7B, CA_7C, CA_38C, CA_41C, CA_41A-41A, CA_7A-7A, CA_2A-38A, CA_5A-41A, CA_5A-66A, CA_7A-66A, CA_2A-2A, CA_2A-5A, CA_2A-7A, CA_2A-12A, CA_4A-5A, CA_4A-7A, CA_5A-7A, CA_12A-66A, CA_66A-66A, CA_4A-4A, CA_26A-41A, CA_5A-38A, CA_2A-4A, CA_38A-66A, CA_26A-38A, CA_2A-66A, CA_7A-26A 5G Network SA: NR n5/n7/n38/n41/n66 NSA UL (EN-DC): DC_7A_n5A, DC_66A_n5A, DC_2A_n7A, DC_4A_n7A, DC_5A_n7A, DC_7A_n7A, DC_66A_n7A, DC_2A_n66A, DC_5A_n66A, DC_7A_n66A, DC_66A_n66A, DC_2A_n38A, DC_4A_n38A, DC_5A_n38A, DC_38A_n38A, DC_66A_n38A, DC_2A_n41A, DC_4A_n41A, DC_26A_n41A, DC_41A_n41A, DC_66A_n41A DL(EN-DC): DC_7C_n5A, DC_7C_n66A, DC_5A-66A_n66A, DC_7A-66A_n66A, DC_2A-5A_n66A, DC_5A-7A_n7A, DC_5A7A_n66A, DC_66A-66A_n5A, DC_66A-66A_n7A NR CA Downlink (DL): CA_n5A-n7A, CA_n7B Bluetooth (BR+EDR+BLE) 2.4G WIFI 802.11b, 802.11g, 802.11n(HT20/40) and VHT(20/40) 5G WIFI 802.11a, 802.11n(HT20/40) and 802.11ac(VHT20/40/80) U-NII-1/2A/2C/3, GPS, GLONASS, BDS, Galileo, NFC Class B 5850 MHz Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 7 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 3 SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 47 CFR Part 15 Subpart B Unintentional Radiators American National Standard for Methods of Measurement of Radio-Noise Emissions from Low- 2 ANSI C63.4-2014 Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz 3.2 Verdict No. Description 1 Radiated Emission 2 Conducted Emission, AC Ports FCC Rule 15.109 15.107 Test Verdict Pass Pass Remark --- 3.3 Test Uncertainty The following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Measurement Conducted emissions (9 kHz-30 MHz) Radiated emissions (30 MHz-1 GHz)-966#2 Radiated emissions (1 GHz-18 GHz)-966#2 Value 3.2 dB 4.4 dB 5.0 dB Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 8 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 4 GENERAL TEST CONFIGURATIONS 4.1 Test Enclosure List Description Wireless Communications Test Set Manufacturer R&S Laptop Lenovo Laptop Data connector USB disk HONOR UGREEN Sandisk TF Card SAMSUNG Headset Type-C Headset OPPO OPPO Model CMW500 ThinkPad E495 N/A 40702 DTMC3G2 MB- MD256KA MH156 MH156 Serial No. 102318 N/A N/A N/A N/A N/A N/A N/A Length Description Use N/A Cal. Due 2025.05.08 N/A N/A N/A N/A N/A N/A N/A 64G N/A 256G 1.12m N/A 1.12m N/A Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 9 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 4.2 Test Configurations All test modes of EUT are listed in the table below. Test Mode Configuration Description Mode 1 The GSM 850 MHz RX Test Mode GSM 850 MHz RX + EUT +Adapter + USB Cable + Battery + Headset Mode 2 The EGPRS 850 MHz RX Test Mode EGPRS 850 MHz RX + EUT +Adapter + USB Cable + Battery + Headset Mode 3 The WCDMA Band 5 RX Test Mode WCDMA Band 5 RX + EUT +Adapter + USB Cable + Battery + Headset Mode 4 The FDD LTE Band 5 RX Test Mode LTE Band 5 RX + EUT +Adapter + USB Cable + Battery + Headset Mode 5 The FDD LTE Band 12 RX Test Mode LTE Band 12 RX + EUT +Adapter + USB Cable + Battery + Headset Mode 6 The FDD LTE Band 13 RX Test Mode LTE Band 13 RX + EUT +Adapter + USB Cable + Battery + Headset Mode 7 The FDD LTE Band 17 RX Test Mode LTE Band 17 RX + EUT +Adapter + USB Cable + Battery + Headset Mode 8 The FDD LTE Band 26 RX Test Mode LTE Band 26 RX + EUT +Adapter + USB Cable + Battery + Headset Mode 9 The n5 Test Mode RX Test Mode n5 RX + EUT +Adapter + USB Cable + Battery + Headset Mode 10 The Standby Test Mode EUT + Adapter + USB Cable + Battery + Headset Mode 11 The Front Camera Test Mode EUT + Adapter + USB Cable + Battery + Headset Mode 12 The Rear Camera Test Mode EUT + Adapter + USB Cable + Battery + Headset Mode 13 The Video Play Test Mode EUT + Adapter + USB Cable + Battery + Headset Mode 14 The USB Test Mode EUT + USB Cable + Battery + Laptop + Headset Mode 15 The OTG Test Mode EUT + Battery + Data connector + USB Disk Mode 16 The Type-C Headset Test Mode EUT + Type-C Headset + Battery Test Case Radiated Emission Test Mode Configuration Mode 1~Mode 16 Worst Mode 11, 14 Conducted Emission, AC Ports Mode 1~Mode 14 12, 14 Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 10 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Test Case Test Mode Configuration Worst Mode Note: All operation modes were tested, but only test data of the worst mode was presented in this report. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 11 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 4.3 Test Setups Test Setup 1 Radiated Emission (30 MHz-1 GHz) Radiated Emission (above 1 GHz) Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 12 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Test Setup 2 Conducted Emissions, AC Ports Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 13 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 5 TEST ITEMS 5.1 Emission Tests 5.1.1 Radiated Emission 5.1.1.1 Limit Frequency range (MHz) Class B (at 3 m) Field Strength Field Strength (µV/m) (dBµV/m) 30 - 88 100 40 88 - 216 150 43.5 216 - 960 200 46 Above 960 500 54 NOTE: 1) Field Strength (dBµV/m) = 20*log [Field Strength (µV/m)]. 2) In the emission tables above, the tighter limit applies at the band edges. 3) For 30 MHz to 1000 MHz, the CISPR quasi-peak is employed. Class A (at 3 m) Field Strength (dBµV/m) 49.5 54 56.9 60 For above 1000 MHz, according to the requirements of FCC 15.35, unless otherwise specified, the limit on peak radio frequency emissions is 20 dB above the maximum permitted average emission limit applicable to the equipment under test. Frequency range (GHz) Class B (at 3 m) Field Strength (µV/m) Field Strength Average (dBµV/m) Field Strength Peak (dBµV/m) Class A (at 3 m) Field Strength Field Strength Average Peak (dBµV/m) (dBµV/m) 1 - FM 500 54 74 60 80 Note 1: The highest measurement frequency, FM, in GHz, shall be determined as next Table. Note 2: Average Class A limit at 3m L3m is determined by the following conversion formula: L3m =L10m + 20*log(d10m/d3m) Where: L3m is Average Class A limit at 3m; L10m is Average Class A limit at 10m; d10m is Measurement distance in 10m; d3m is Measurement distance in 3m. For this case: L3m = 49.5 + 20*log(10/3)=60 (dBµV/m). Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 14 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Highest internal frequency (FX) Highest measurement frequency (FM) FX 108 MHz 1 GHz 108 MHz FX 500 MHz 2 GHz 500 MHz FX 1 GHz 5 GHz FX 1 GHz 5 *FX or 40 GHz, whichever is lower. Note: FX is Highest frequency generated or used in the device or on which the device operates or tunes. 5.1.1.2 Test Setup Refer to 4.3 section (test setup 1) for radiated emission test, the photo of test setup please refer to ANNEX B. 5.1.1.3 Test Procedure All Radiated Emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. An initial pre-scan was performed in the chamber using the EMI Receiver in peak detection mode. Quasi-peak measurements were conducted based on the peak sweep graph. The EUT was measured by Bi-Log antenna with 2 orthogonal polarities. The measurement frequency range is from 30 MHz to the 5th harmonic of the maximum frequency of the EUT internal source. The Turn Table is actuated to turn from 0°to 360°, and both horizontal and vertical polarizations of the Test Antenna are used to find the maximum radiated power. Mid channels on all channel bandwidth verified. Only the worst RB size/offset presented. Use the following spectrum analyzer settings: Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1 GHz, 100 kHz for f < 1 GHz VBW RBW Sweep = auto Detector function = peak for f <1 GHz, peak & RMS Average for f 1 GHz Trace = max hold 5.1.1.4 Test Result and Test Equipment List Please refer to ANNEX A.1. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 15 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 NOTE: 1. Results (dBµV/m) = Reading (dBµV) + Factor (dB/m) The reading level is calculated by software which is not shown in the sheet 2. Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) Amplifier Gain (dB) 3. Margin = Limit - Results Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 16 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 5.1.2 Conducted Emission, AC Ports 5.1.2.1 Test Limit Frequency range (MHz) 0.15 - 0.50 0.50 - 30 Quasi-peak (dBµV) 79 73 Class A Average (dBµV) 66 60 Class B Frequency range (MHz) Quasi-peak Average (dBµV) (dBµV) 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 NOTE: 1) The lower limit shall apply at the band edges. 2) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50 MHz. 5.1.2.2 Test Setup Refer to 4.3 section test (test setup 2) for conducted emission, the photo of test setup please refer to ANNEX B. 5.1.2.3 Test Procedure The EUT is connected to the power mains through a LISN which provides 50 /50 µH of coupling impedance for the measuring instrument. The test frequency range is from 150 kHz to 30 MHz. The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average (AV) detectors; the emission levels that are more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz) for which the device is capable of operation. A device rated for 50/60 Hz operation need not be tested at both frequencies provided the radiated and line conducted emissions are the same at both frequencies. Use the following spectrum analyzer settings: RBW = 9 kHz VBW RBW Sweep = 10ms Detector function =peak & Average Trace = max hold Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 17 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 5.1.2.4 Test Result and Test Equipment List Please refer to ANNEX A.2. NOTE: 1. Results (dBµV) = Reading (dBµV) + Factor (dB) The reading level is calculated by software which is not shown in the sheet 2. Factor = Insertion loss + Cable loss 3. Margin = Limit - Results Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 18 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 ANNEX A TEST RESULTS A.1 Radiated Emission Note 1: The symbol of "--" in the table which means not application. Note 2: For the test data above 1 GHz, according the ANSI C63.4-2014, where limits are specified for both average and peak (or quasi-peak) detector functions, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an average measurement. Note 3: The Radiated Emission is required to be investigated to the upper frequency of 5th harmonic of the highest internal frequency of EUT or 40 GHz, whichever is lower. The test results above 18GHz are only noise and are not recorded in the report. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 19 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Sample No. Humidity Test Engineer S31 53%RH He Shichang Test Mode 11 1) Test Antenna Vertical, 30 MHz 1 GHz Temperature Pressure Test Date 21.2 101kPa 2024.06.05 No. Frequency Results (MHz) (dBuV/m) 1 30.611 37.40 1* 30.611 33.72 2 36.208 29.31 3 58.373 25.07 4 81.168 29.17 5 265.613 27.34 6 904.891 34.77 Factor (dB) -28.11 -28.11 -26.89 -25.59 -29.51 -21.79 -4.49 Limit (dBuV/m) 40.0 40.0 40.0 40.0 40.0 46.0 46.0 Margin (dB) 2.60 6.28 10.69 14.93 10.83 18.66 11.23 Detector Peak QP Peak Peak Peak Peak Peak Table (Degree) 121.00 121.00 138.00 66.00 63.00 4.00 300.00 Height (cm) 101 101 100 100 100 200 200 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict N/A Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 20 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 2) Test Antenna Horizontal, 30 MHz 1 GHz No. Frequency Results (MHz) (dBuV/m) 1 30.922 24.51 2 148.583 25.77 3 289.863 30.26 4 313.871 28.39 5 357.909 27.14 6 962.218 36.69 Factor (dB) -28.17 -28.30 -20.88 -20.25 -18.71 -3.52 Limit (dBuV/m) 40.0 43.5 46.0 46.0 46.0 54.0 Margin (dB) 15.49 17.73 15.74 17.61 18.86 17.31 Detector Peak Peak Peak Peak Peak Peak Table (Degree) 43.00 160.00 101.00 120.00 360.00 213.00 Height (cm) 200 200 100 100 100 200 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass Pass Pass Pass Pass Equipment Information Equipment Name Supplier Model Serial No. Cal. Date Cal. Due Use Frequency Below 1 GHz EMI Receiver Amplifier (30-1GHz) Test Antenna- Bi-Log Anechoic Chamber#2 Keysight COM-MV SCHWARZB ECK YiHeng N9038A ZT30-1000M VULB 9168 9m*6m*6m MY55330120 2023.09.05 2024.09.04 B2017119081 2023.12.05 2024.12.04 9168-00867 2022.04.12 2025.04.11 142 2021.08.19 2024.08.18 Description Supplier Name Version / Use Test Software BALUN BL410-E V22.930 / Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 21 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 3) Test Antenna Vertical, 1 GHz 18 GHz No. Frequency Results (MHz) (dBuV/m) 1 1242.000 38.59 1** 1242.000 29.31 2 1530.500 40.16 2** 1530.500 29.70 3 4991.250 54.28 3** 4991.250 45.50 4 5754.750 56.23 4** 5754.750 46.93 5 6960.500 55.77 5** 6960.500 44.76 6 14042.000 56.50 6** 14042.000 45.87 Factor (dB) -16.24 -16.24 -16.00 -16.00 2.11 2.11 3.38 3.38 1.30 1.30 5.08 5.08 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 35.41 24.69 33.84 24.30 19.72 8.50 17.77 7.07 18.23 9.24 17.50 8.13 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 301.00 301.00 123.00 123.00 281.00 281.00 0.00 0.00 226.00 226.00 50.00 50.00 Height (cm) 100 100 100 100 100 100 100 100 100 100 100 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 22 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 4) Test Antenna Horizontal, 1 GHz 18 GHz No. Frequency Results (MHz) (dBuV/m) 1 1326.900 39.33 1** 1326.900 30.74 2 2025.400 42.81 2** 2025.400 33.51 3 4299.000 51.78 3** 4299.000 41.78 4 6394.250 55.28 4** 6394.250 45.08 5 10057.500 53.81 5** 10057.500 43.84 6 13370.500 56.22 6** 13370.500 47.23 Factor (dB) -16.03 -16.03 -13.47 -13.47 -0.28 -0.28 1.84 1.84 2.44 2.44 5.10 5.10 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 34.67 23.26 31.19 20.49 22.22 12.22 18.72 8.92 20.19 10.16 17.78 6.77 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 127.00 127.00 52.00 52.00 43.00 43.00 153.00 153.00 179.00 179.00 245.00 245.00 Height (cm) 100 100 100 100 100 100 100 100 100 100 100 100 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 23 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Equipment Information Equipment Name Supplier Model Serial No. Cal. Date Cal. Due Use Frequency Above 1 GHz EMI Receiver Amplifier (1-12GHz) Amplifier 0.8-21GHz Test AntennaHorn Anechoic Chamber#2 Keysight Advanced Microwave Mini-Circuits SCHWARZB ECK YiHeng N9038A WLA652A ZVA-213-S+ BBHA 9120D 9m*6m*6m MY55330120 2023.09.05 2024.09.04 1740103 2023.12.05 2024.12.04 225321316 2023.12.05 2024.12.04 01917 2022.06.09 2025.06.08 142 2021.08.19 2024.08.18 Description Supplier Name Version / Use Test Software BALUN BL410-E V22.930 / Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 24 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Test Mode 14 5) Test Antenna Vertical, 30 MHz 1 GHz No. Frequency Results (MHz) (dBuV/m) 1 44.869 42.70 1* 44.869* 33.99 2 87.133 27.37 3 280.890 30.33 4 399.813 34.80 5 451.077 35.79 6 572.230 34.96 Factor (dB) -25.66 -25.66 -29.37 -24.12 -20.95 -19.86 -16.98 Limit (dBuV/m) 40.0 40.0 40.0 46.0 46.0 46.0 46.0 Margin (dB) -2.70 6.01 12.63 15.67 11.20 10.21 11.04 Detector Peak QP Peak Peak Peak Peak Peak Table (Degree) 249.00 249.00 188.00 299.00 205.00 153.00 290.00 Height (cm) 106 106 100 200 100 100 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict N/A Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 25 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 6) Test Antenna Horizontal, 30 MHz 1 GHz No. Frequency Results (MHz) (dBuV/m) 1 44.682 40.57 1* 44.682* 33.78 2 133.354 29.62 3 166.139 26.90 4 232.536 32.76 5 270.948 34.59 6 399.716 34.49 Factor (dB) -25.59 -25.59 -30.02 -29.30 -25.43 -24.40 -20.95 Limit (dBuV/m) 40.0 40.0 43.5 43.5 46.0 46.0 46.0 Margin (dB) -0.57 6.22 13.88 16.60 13.24 11.41 11.51 Detector Peak QP Peak Peak Peak Peak Peak Table (Degree) 209.00 209.00 271.00 225.00 236.00 252.00 212.00 Height (cm) 198 198 200 200 100 100 100 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal N/A Pass Pass Pass Pass Pass Pass Equipment Information Equipment Name Supplier Model Serial No. Cal. Date Cal. Due Use Frequency Below 1 GHz EMI Receiver Amplifier (30-1GHz) Test Antenna- Bi-Log Anechoic Chamber#2 Keysight COM-MV SCHWARZB ECK YiHeng N9038A ZT30-1000M VULB 9168 9m*6m*6m MY55330120 2023.09.05 2024.09.04 B2017119081 2023.12.05 2024.12.04 9168-00867 2022.04.12 2025.04.11 142 2021.08.19 2024.08.18 Description Supplier Name Version / Use Test Software BALUN BL410-E V22.930 / Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 26 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 7) Test Antenna Vertical, 1 GHz 18 GHz No. Frequency Results (MHz) (dBuV/m) 1 1199.600 49.27 1** 1199.600 39.04 2 2794.200 52.26 2** 2794.200 40.01 3 4198.750 51.08 3** 4198.750 41.92 4 7721.500 56.44 4** 7721.500 45.66 5 11956.500 54.84 5** 11956.500 45.43 6 13647.000 56.26 6** 13647.000 46.87 Factor (dB) -16.22 -16.22 -8.39 -8.39 -0.30 -0.30 2.24 2.24 2.64 2.64 5.11 5.11 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 24.73 14.96 21.74 13.99 22.92 12.08 17.56 8.34 19.16 8.57 17.74 7.13 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 232.00 232.00 156.00 156.00 300.00 300.00 53.00 53.00 360.00 360.00 34.00 34.00 Height (cm) 100 100 100 100 100 100 100 100 100 100 100 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 27 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 8) Test Antenna Horizontal, 1 GHz 18 GHz No. Frequency Results (MHz) (dBuV/m) 1 1199.900 49.55 1** 1199.900 39.63 2 2800.300 51.30 2** 2800.300 36.75 3 3925.250 51.13 3** 3925.250 39.71 4 5070.250 54.84 4** 5070.250 44.59 5 7932.750 56.71 5** 7932.750 46.00 6 13570.500 57.41 6** 13570.500 46.66 Factor (dB) -16.21 -16.21 -8.13 -8.13 -1.66 -1.66 1.58 1.58 3.15 3.15 4.73 4.73 Limit (dBuV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 24.45 14.37 22.70 17.25 22.87 14.29 19.16 9.41 17.29 8.00 16.59 7.34 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 223.00 223.00 164.00 164.00 119.00 119.00 263.00 263.00 209.00 209.00 170.00 170.00 Height (cm) 100 100 100 100 100 100 100 100 100 100 100 100 Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 28 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Equipment Information Equipment Name Supplier Model Serial No. Cal. Date Cal. Due Use Frequency Above 1 GHz EMI Receiver Amplifier (1-12GHz) Amplifier 0.8-21GHz Test AntennaHorn Anechoic Chamber#2 Keysight Advanced Microwave Mini-Circuits SCHWARZB ECK YiHeng N9038A WLA652A ZVA-213-S+ BBHA 9120D 9m*6m*6m MY55330120 2023.09.05 2024.09.04 1740103 2023.12.05 2024.12.04 225321316 2023.12.05 2024.12.04 01917 2022.06.09 2025.06.08 142 2021.08.19 2024.08.18 Description Supplier Name Version / Use Test Software BALUN BL410-E V22.930 / Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 29 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 A.2 Conducted Emission, AC Ports Note 1: Measurements shall be made with a quasi-peak measuring receiver in the frequency range 0.15MHz to 30 MHz. To reduce the testing time, a peak measuring receiver may be used instead of a quasi-peak measuring receiver. In case of dispute, measurement with a quasi-peak measuring receiver will take precedence. Note 2: Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz) for which the device is capable of operation. So, The configuration 120 VAC, 60 Hz and 240 VAC, 50 Hz were tested respectively, but only the worst configuration (120 VAC, 60 Hz ) shown here. Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 30 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Sample No. Humidity Test Engineer S31 54%RH Yang Yang Test Mode 12 1) AC Ports - L Phase Temperature Pressure Test Date 22.1 101kPa 2024.06.04 No. Frequency Results (MHz) (dBuV) 1 0.164 39.59 1** 0.164 32.70 2 0.286 43.36 2** 0.286 27.86 3 0.408 41.18 3** 0.408 29.61 4 1.394 38.33 4** 1.394 21.60 5 5.880 41.74 5** 5.880 32.82 6 22.880 43.93 6** 22.880 34.64 Factor (dB) 10.09 10.09 10.06 10.06 10.64 10.64 10.85 10.85 10.96 10.96 13.24 13.24 Limit (dBuV) 65.26 55.26 60.64 50.64 57.69 47.69 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 25.67 22.56 17.28 22.78 16.51 18.08 17.67 24.40 18.26 17.18 16.07 15.36 Detector Line Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 31 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 2) AC Ports - N Phase No. Frequency Results (MHz) (dBuV) 1 0.150 42.09 1** 0.150 36.68 2 0.296 45.30 2** 0.296 35.06 3 0.444 42.30 3** 0.444 31.94 4 3.962 43.09 4** 3.962 29.76 5 5.876 43.30 5** 5.876 32.57 6 21.658 45.10 6** 21.658 35.84 Factor (dB) 10.11 10.11 10.07 10.07 10.59 10.59 10.62 10.62 10.92 10.92 13.47 13.47 Limit (dBuV) 66.00 56.00 60.35 50.35 56.99 46.99 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 23.91 19.32 15.05 15.29 14.69 15.05 12.91 16.24 16.70 17.43 14.90 14.16 Detector Line Peak N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 32 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Test Mode 14 3) AC Ports - L Phase No. Frequency Results (MHz) (dBuV) 1 0.150 63.04 1* 0.150 59.72 1** 0.150 42.16 2 0.182 55.84 2** 0.182 37.23 3 0.420 45.29 3** 0.420 32.06 4 4.744 37.37 4** 4.744 27.51 5 15.334 36.39 5** 15.334 23.78 6 22.478 37.25 6** 22.478 27.37 Factor (dB) 10.11 10.11 10.11 10.07 10.07 10.62 10.62 10.79 10.79 12.71 12.71 13.36 13.36 Limit (dBuV) 66.00 66.00 56.00 64.39 54.39 57.45 47.45 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 2.96 6.28 13.84 8.55 17.16 12.16 15.39 18.63 18.49 23.61 26.22 22.75 22.63 Detector Line Peak L QP L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Verdict N/A Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 33 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 4) AC Ports - N Phase No. Frequency Results (MHz) (dBuV) 1 0.150 62.58 1* 0.150 58.92 1** 0.150 44.77 2 0.158 61.01 2* 0.158 57.42 2** 0.158 37.22 3 0.400 46.55 3** 0.400 30.81 4 1.218 37.60 4** 1.218 23.64 5 15.502 36.30 5** 15.502 20.44 6 22.206 36.54 6** 22.206 22.95 Factor (dB) 10.11 10.11 10.11 10.10 10.10 10.10 10.65 10.65 10.47 10.47 12.71 12.71 13.24 13.24 Limit (dBuV) 66.00 66.00 56.00 65.57 65.57 55.57 57.85 47.85 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 3.42 7.08 11.23 4.56 8.15 18.35 11.30 17.04 18.40 22.36 23.70 29.56 23.46 27.05 Detector Line Peak N QP N AV N Peak N QP N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Verdict N/A Pass Pass N/A Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 34 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Equipment Information Equipment Name Supplier Model Serial No. Cal. Date Cal. Due Use EMI Receiver LISN ISN KEYSIGHT SCHWARZB ECK TESEQ N9010B NSLK 8127 ISN T800 MY57110309 8127-687 34449 2023.09.05 2024.09.04 2024.05.09 2025.05.08 2023.11.10 2024.11.09 ISN Shielded Room Description TESEQ YiHeng Electronic Co., Ltd Supplier ISN T8-Cat6 3.5m*3.1m*2. 8m Name 53561 112 Version 2024.04.24 2025.04.23 2022.02.19 2025.02.18 / Use Test Software BALUN BL410-E V22.930 / Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 35 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 ANNEX B TEST SETUP PHOTOS Please refer the document "BL-SZ2460066-AE-1.PDF". ANNEX C EUT EXTERNAL PHOTOS Please refer the document "BL-SZ2460066-AW.PDF". ANNEX D EUT INTERNAL PHOTOS Please refer the document "BL-SZ2460066-AI.PDF". Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 36 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2460066-401 Statement 1. The laboratory guarantees the scientificity, accuracy and impartiality of the test, and is responsible for all the information in the report, except the information provided by the customer. The customer is responsible for the impact of the information provided on the validity of the results. 2. The report without China inspection body and laboratory Mandatory Approval (CMA) mark has no effect of proving to the society. 3. For the report with CNAS mark or A2LA mark, the items marked with "" are not within the accredited scope. 4. This report is invalid if it is altered, without the signature of the testing and approval personnel, or without the "inspection and testing dedicated stamp" or test report stamp. 5. The test data and results are only valid for the tested samples provided by the customer. 6. This report shall not be partially reproduced without the written permission of the laboratory. 7. Any objection shall be raised to the laboratory within 30 days after receiving the report. --END OF REPORT-- Tel: +86-755-66850100 E-mail: qc@baluntek.com Page No. 37 / 37 Web: www.titcgroup.com Template No.: TRP-FCC 15B (2023-07-01) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China钛和检测认证集团股份有限公司