User Manual for victron energy models including: BMV-700, MPPT Control Display Manual, MPPT Control Display, Control Display, MPPT Display, BMV-700, Display

MPPT Control display manual

Victron MPPT Control Manual

Victron MPPT Control | Battle Born Batteries

MPPT Control display manual


File Info : application/pdf, 16 Pages, 655.33KB

PDF preview unavailable. Download the PDF instead.

MPPT Control display manual-en
ENGLISH
MPPT Control display manual
Rev 00 04/2021

MPPT Control display manual
Table of Contents
1. Introduction ........................................................................................................................... 1
2. Mounting ............................................................................................................................... 3
3. Installation ............................................................................................................................. 5
4. Operation .............................................................................................................................. 7 4.1. Status menu .................................................................................................................. 8 4.2. History menu ................................................................................................................. 8 4.3. Settings menu .............................................................................................................. 10
5. Troubleshooting and Support ................................................................................................... 12 5.1. Power issues ............................................................................................................... 12 5.2. Connection issues ......................................................................................................... 12 5.3. Settings locked ............................................................................................................ 12
6. Warranty ............................................................................................................................. 13
7. Specifications ....................................................................................................................... 14

MPPT Control display manual
1. Introduction
The MPPT Control display is a dedicated display for the Victron Energy SmartSolar and BlueSolar MPPT solar charger range. It can be used to read out the live and historic solar charger data and it can be used to configure solar charger settings. Examples of live and historic monitoring: · PV power, yield, voltage and current. · Battery voltage, current and charge stage. · Load output state and current (only available if the solar charger is equipped with a load output). · 30-day historical values · Cumulative historic values over the live of the solar charger

The MPPT Control display
The MPPT Control display can be used with the whole range of BlueSolar and SmartSolar MPPT solar chargers. However, for solar chargers rated 60A consider using the better suited SmartSolar Control display instead.
Power cable The display ships together with a fused power cable. The supplied power cable is only needed when the display is used with some very early solar charger models that have been since long discontinued. These early models shut down when they do not receive solar power. The power cable provides power to the display straight from the battery so that the display is also operational during bad weather of after the sun has gone down.

Power cable
VE.Direct cable A VE.Direct cable is needed to connect the display to the solar charger. This cable is not included with the MPPT Control display and needs to be purchased separately. VE.Direct cables vary in lengths from 0.3 up to 10 meter and are available with straight or right angle connectors. For more information see the VE.Direct cable product page.

Page 1

VE.Direct cable

Introduction

MPPT Control display manual Wall mounting enclosure The housing of the MPPT Control display is tailored towards being flush mounted through a panel. In case flush mounting is not possible a dedicated wall mount enclosure can be used. This enclosure allows for easy wall mounting of the display. There are two wall mounting options: · Wall mount enclosure for BMV or MPPT Control · Wall mount enclosure for BMV and Color Control GX
Wall mount enclosure for BMV or MPPT Control

Page 2

Introduction

MPPT Control display manual
2. Mounting
Drill a hole in a mounting substrate as indicated in below figure.

Mounting recess width and depth requirements
Mount the display: Use option A if the mounting substrate is accessible from both sides Use option B if the mounting substrate is accessible from the front.

1

2

Mounting option A

Option A

Page 3

Mounting

MPPT Control display manual

1

2

3

4

5

Mounting option B

Option B

Page 4

Mounting

MPPT Control display manual
3. Installation
Connect the solar charger Connect the MPPT Control display to the solar charger using a VE.Direct cable. It is not possible to extend the VE.Direct cable, the maximum length can not exceed 10 meter.

Power

VE.Direct

The rear of the MPPT Control display showing the power connection and the VE.Direct connection

VE.Direct cable
Connect the display to the solar charger via a VE.Direct cable
Connect the power cable (only needed for old style solar controllers)
The supplied power cable is only necessary when the display is used with some very early solar charger models that have been since long discontinued.
Connect the power cable as follows: · Connect the black wire ring cable lug to the negative battery terminal. If a battery monitor is used in the system, connect the
black wire to the system side of the battery monitor shunt instead. · Connect the red cable ring cable lug to the positive battery terminal. · Plug the the RJ12 terminal into the power terminal on the back of the display.

Page 5

Installation

MPPT Control display manual

To battery

Fuse
Connect the display to an old model solar charger and the battery

VE.Direct cable

Page 6

Installation

MPPT Control display manual
4. Operation
The LCD screen displays the following information: · A number reading. · The unit of the reading: V, A, W, kWh, h or ! · The type of reading: load, battery, PV, min, max or charge stage. · Connection status indicator.
Full LCD readout

The digits used to represent letters and numbers

The connection status of the display is indicated by a "double arrow" symbol as indicated in below table.

Indicator On Blinking
Off

connection status
There is a connection between the display and the solar charger
There was a connection with the solar charger but the connection is lost. The last know values will be shown.
There has not been a connection with a solar charger.

The buttons on the front of the display are used to navigate through the solar charger readings and are used when making solar controller and display settings.They have the following functions:

Button

Action

Cancel or
Back

Select or
Confirm

Go to next or previous item or
Increase or decrease value

Page 7

Operation

MPPT Control display manual

4.1. Status menu
This menu shows the live solar charger readings. The MPPT Control display always starts up in this menu. Press the up and down button cycle through all menu items. These menu items will be displayed in order of appearance as indicated in below table:

LCD Display

Menu item

Description and notes

PV power

Solar array output power.

PV voltage

Solar array voltage.

PV daily yield

The daily accumulative solar power received.

Battery error

Only visible in case there is an active error.

Battery charge stage

Charge stage: Bulk, Absorption, Float, Off or Fault.

Battery current

Battery charge current.

Battery voltage

Battery voltage.

Load output state Load current

Load output switched on or off. Only visible on MPPTs with a load output.
The current into the load. Only visible on MPPTs with a load output.

4.2. History menu
The history menu shows both the daily and overall solar charger history data. It shows items such as solar yield, battery voltages, time spend in each charge stage and past errors.
To enter and readout the history menu:
· Press the SELECT button, while in the status menu. · Press the up or down button to navigate through the history items. · When arriving at the desired history item, press the SELECT button to see the value of that item. · If an item contains multiple values, press the SELECT button and then the up or down button to browse the various values
within that item. For the daily items it is possible to scroll back to 30 days ago (data becomes available over time), a brief popup shows the day number. · To go back to the main history menu press the SETUP button. · To go back to the status menu press the SETUP button again.

Page 8

Operation

MPPT Control display manual

History menu navigation chart

All available history menu items are listed in below table, in the order they appear when scrolling through the items.

LCD

Scrolling text

Description

TOTAL YIELD

The cumulative PV yield since the last history reset.

MAX PANEL VOLTAGE

The maximum PV voltage since the last history reset.

MAX BATTERY VOLTAGE

The maximum battery voltage since the last history reset.

MIN BATTERY VOLTAGE

The minimum battery voltage since the last history reset.

LAST ERRORS YIELD

The last 4 errors since the last history reset. The number of blocks in the lower right of the LCD determines which error is currently shown, with 1 block being the latest and 4 blocks being the oldest.
The daily PV yield, available for each day for the past 30 days.

MAX POWER

The daily maximum PV power, available for each day for the past 30 days.

MAX PANEL VOLTAGE

The daily maximum PV voltage, available for each day for the past 30 days.

MAX BATTERY CURRENT

The daily maximum battery current, available for each day for the past 30 days.

MAX BATTERY VOLTAGE

The daily maximum battery voltage, available for each day for the past 30 days.

MIN BATTERY VOLTAGE

The daily minimum battery voltage, available for each day for the past 30 days.

BULK TIME

The daily time spent in the bulk charge stage, available for each day for the past 30 days.

ABSORPTION TIME

The daily time spent in the bulk absorption stage, available for each day for the past 30 days.

Page 9

Operation

MPPT Control display manual

LCD

Scrolling text FLOAT TIME
LAST ERRORS

Description
The daily time spent in the float stage, available for each day for the past 30 days.
The last 4 daily errors. The number of blocks in the lower right of the LCD determines which error is currently shown, with 1 block being the latest and 4 blocks being the oldest.

4.3. Settings menu
In the settings menu the the solar charger and MPPT Control settings can be viewed and changed.
Do not change settings unless you know what they are and what the effect of changing these setting can be. Incorrect settings may cause system problems including damage to batteries. When in doubt, seek advice from and experienced Victron Energy installer, dealer or distributor.
To navigate the settings menu:
· Press the SETUP button for 2 seconds to enter the settings menu · The first menu item is shown. · Navigate to the desired menu item by pressing the up and down button. · Once arrived at the desired menu item, press the SELECT button to view the value the setting has been set to. · To modify this setting press the SELECT button again. teh value will now blink. · Press the up or down button to choose the desired value. · Press SELECT to confirm the change, you will hear a beep and will see the word SAVED. The change is made final. · Navigate to the next menu item, or press SETUP to return to the setup menu. · To leave the setting menu, press the SETUP button again.
It might be possible that the setup menu is locked, in which case the settings can only be viewed. When trying to change the setting the word LOCK is shown.
To unlock the settings menu:
· Navigate to settings menu item 01 LOCK SETUP · Press the SETUP button, the setting ON is displayed · Press the SETUP button again · Press the down arrow button and select OFF · To leave the setting press the SETUP button.
When SELECT TO EDIT is ON, the current value is shown and a new value can immediately be selected.
When LOCK SETUP is ON, settings can only be changed after setting LOCK SETUP to off

MPPT Control setting navigation chart
All available settings are indicated in below table, in the order they appear when scrolling trough the menu, together with a basic description of each setting. For the full description of the solar charger settings refer to the solar charger manual.
Not all setting listed in below table might be available when connecting to certain models of solar chargers. The solar charger might not have the necessary hardware. For example, not all solar chargers are equipped with a load output.

Page 10

Operation

MPPT Control display manual

Some settings might be missing from the settings menu. The MPPT Control display only allows to change the most common settings. More advance settings, like TX and RX port settings, are not accessible via the MPPT Control display. To configure these settings use the VictronConnect App or, for solar chargers 60A and up, use a SmartSolar Control display.

Number 01

Name LOCK SETUP

02

BATTERY VOLTAGE

03

BATTERY TYPE

04

MAXIMUM CURRENT

05

BULK TIME LIMIT

06

ABSORPTION TIME LIMIT

07

ABSORPTION VOLTAGE

08

FLOAT VOLTAGE

09

TEMP COMPENSATION

10

LOAD OUTPUT

11

LOAD SWITCH HIGH

12

LOAD SWITCH LOW

13

CLEAR HISTORY

14

FACTORY DEFAULTS

15

BACKLIGHT INTENSITY

16

BACKLIGHT ALWAYS ON

17

SCROLL SPEED

18

SELECT TO EDIT

19

AUTO LOCK

20

SOFTWARE VERSION

21

SERIAL NUMBER

22

MPPT SOFTWARE

VERSION

23

MPPT SOFTWARE

VERSION

24

EQUALISATION VOLTAGE

25

EQUALIZE

Setting When set to ON, none of the other settings can be changed. If an attempt is made to change a setting the word "LOCK" is shown together with the setting value. Set to OFF to unlock, so other settings can be changed. The system battery voltage; choose between a voltage setting or AUTO. When set to automatic (AUTO), an A will be shown in front of the voltage setting. The charge algorithm for a specific battery type; set to FIXED or USER. When set to FIXED, the rotary switch on the solar charger determines the battery type. When set to USER, all charging related settings can be edited. As soon as any of the charging related settings are changed, this setting will automatically set to USER. The maximum charging current. The maximum time the bulk charge stage is allowed to last. The maximum time the absorption charge stage is allowed to last. The battery voltage at which the solar charger switches from bulk to absorption stage. The battery voltage at which the solar charger switches from absorption to float stage. The temperature compensation coefficient in mV/°C for the whole battery bank (not per individual battery). The Load output operating mode. Possible values: OFF, AUTO (= BatteryLife), ALT1, ALT2, ON, USER1, USER2 The high voltage level in case LOAD OUTPUT is set to USER1 or USER2 The low voltage level in case LOAD OUTPUT is set to USER1 or USER2 Clears the solar charger history Resets the solar charger settings back to factory defaults. Sets the back-light intensity of the MPPT Control LCD display. Determines whether the back-light of the MPPT Control LCD display is always on. Determines the scroll speed of the MPPT Control. When set to OFF, the MPPT Control first shows the value of a setting and SELECT has to be pressed to be able to edit the value. When set to ON, the LOCK SETUP setting will be automatically set to ON 2 minutes after a setting has been changed. The software (firmware) version of the MPPT Control. The serial number of the MPPT Control. The software (firmware) version of the solar charger.
The serial number of the solar charger.
Equalization voltage. Initiates a manual equalization.

Page 11

Operation

MPPT Control display manual
5. Troubleshooting and Support
Consult this chapter in case of unexpected behaviour or if you suspect a product fault. The correct troubleshooting and support process is to first consult the common issues as described in this chapter. Should this fail to resolve the issue, contact the point of purchase for technical support. If the point of purchase is unknown, refer to the Victron Energy Support webpage.
5.1. Power issues
The display is powered via the VE.Direct cable or via the power cable. If the display does not power up check these cables.
VE.Direct cable check:
1. Check if the VE.Direct is plugged into the back of the display 2. Check if the VE.Direct cable is plugged into the solar charger 3. Make sure the VE.Direct connectors are inserted all the way into the VE.Direct ports. 4. Check the VE.Direct port pins; ensure that they are not damaged, bend or missing. 5. Check if the solar charger is able to provide power via the VE.Direct cable when no PV input (at night). Some very early solar
chargers models, that have been since long discontinued need to have the power cable installed.
Power cable check
1. Check the fuse in the power cable. 2. Check if the power cable is plugged into the back of the display. 3. Check if the power cable is connected to the battery or to another supply voltage. 4. Check if the supply voltage is between 6.5 and 95 Vdc.
5.2. Connection issues
If the display is unable to make a connecting with the solar charger or if the text: "Disconnected " is scrolling through the screen, the MPPT Control has not established communications with the solar charger. The most likely cause is an issue with the VE.Direct cable.
VE.Direct cable check
1. Check if the VE.Direct is plugged into the back of the display. 2. Check if the VE.Direct cable is plugged into the solar charger. 3. Make sure the VE.Direct connectors are inserted all the way into the VE.Direct ports. 4. Check the VE.Direct port pins; ensure that they are not damaged, bend or missing.
5.3. Settings locked
If the setup menu is locked settings can only be viewed but not changed. When trying to change the setting the word LOCK is shown. To unlock the settings menu see the instruction in the Settings menu [10] chapter.

Page 12

Troubleshooting and Support

MPPT Control display manual
6. Warranty
This product has a 5-year limited warranty. This limited warranty covers defects in materials and workmanship in this product and lasts for five years from the date of original purchase of this product. To claim warranty the customer must return the product together with the receipt of purchase to the point of purchase. This limited warranty does not cover damage, deterioration or malfunction resulting from alteration, modification, improper or unreasonable use or misuse, neglect, exposure to excess moisture, fire, improper packing, lightning, power surges, or other acts of nature. This limited warranty does not cover damage, deterioration or malfunction resulting from repairs attempted by anyone unauthorized by Victron Energy to make such repairs. Non-compliance with the instructions in this manual will render the warranty void. Victron Energy is not liable for any consequential damages arising from the use of this product. The maximum liability of Victron Energy under this limited warranty shall not exceed the actual purchase price of the product.

Page 13

Warranty

MPPT Control display manual

7. Specifications

Electrical

Supply voltage range when powered from battery

6.5 - 95Vdc

Supply voltage range when powered via VE.Direct cable

5Vdc

Power consumption with back-light turned off

< 0.05W

Operating temperature range

-20 - +50°C (0 - 120°C)

Power cable fuse rating

100mA

Installation type Front diameter Front bezel Body diameter Body depth Power cable length Weight

Mechanical Flush mount 63mm (2.5") 69 x 69mm (2.7x2.7") 52mm (2.0") 31mm (1.2") 1.5m 50g

Suitability
Suitable for the entire Victron Energy BlueSolar MPPT and the SmartSolar MPPT solar charger range, with the exception of the (since long) discontinued BlueSolar MPPT 70/15.

Page 14

Specifications



References

GPL Ghostscript 9.50 AH XSL Formatter V6.6 R1 for Linux64 : 6.6.1.34539 (2018/08/29 13:12JST)