Smart Aromatherapy Diffuser - Operation and Maintenance

Please read carefully before use and keep this manual properly. A warranty is provided within 12 months after the purchase date for all qualified machines.

Operation

This manual covers both conventional and Bluetooth models of the aromatherapy diffuser.

Function Keys

  • MODE: Adjusts different functions including current time, 5 working periods, work/pause intervals, and aroma concentration. Long press for 10 seconds to restore factory settings.
  • SET: Initiates program settings for time, date, and aroma concentration. Long press for 10 seconds to lock/unlock settings.
  • UP: Increases function values (time, concentration, working days). Press and hold for 3 seconds to turn the fan on/off.
  • DOWN: Decreases function values (time, concentration, working days).

Bluetooth Models Specifics

  • Bluetooth model indicator light: Green light indicates working, red light indicates pause, blue flashing light indicates Bluetooth setup. (Conventional model: working light is always green, off when stopped).
  • Oil volume level indicator light: Green light indicates 100%-50% oil level. Blue light indicates 50%-10% oil level. Red light indicates less than 10% oil level, requiring a refill.
  • Bluetooth: Displayed when connecting.
  • Oil level: Displays the current oil level.
  • Lock/unlock: Indicates the lock status.

Function keys are the same as conventional models. When restoring factory settings, key settings are default. Bluetooth connection takes priority.

System Time Setting

  1. Press [SET]. The hour figure on the LCD will flash. Use [UP/DOWN] to adjust the hour.
  2. Press [SET] again. The minute figure will flash. Use [UP/DOWN] to adjust the minutes.
  3. Press [SET] a third time. The indicated date will flash. Use [UP/DOWN] to adjust the current date.
  4. Press [SET] a fourth time to finish all settings.

Set Working Periods (5 groups)

Setting Working Time Ranges:

  1. Press [MODE] to cycle through settings. The LCD shows the factory-set time. You can set 5 working time periods. Example: 08:00-10:00, 11:00-12:00, 13:00-14:00. For continuous operation over midnight, set two periods, e.g., 08:00-23:59 and 00:01-06:00.
  2. Setting Start Time: Press [SET] to enter start time setting. The hour flashes; use [UP/DOWN] to adjust. Press [SET] again for minutes; use [UP/DOWN] to adjust. Press [SET] a third time to set the week. Use [UP] to display the 'Δ' symbol for selected working days in the top week column. Use [DOWN] to move right for other week combinations.
  3. Setting End Time: Press [MODE] to set the end time range. Press [SET] to adjust the end hour, then press [SET] again to adjust the end minute.
  4. Setting Aroma Concentration: Press [MODE] to set device work density. Use [UP/DOWN] to adjust density (5s to 300s).
  5. Setting Pause Density: Press [MODE] to set device pause density. Use [UP/DOWN] to adjust density (5s to 300s, minimum 20s for pause).

After setting, continue pressing [MODE] to set the next period or return to the LCD home page.

Product Parameters

  • Size: 212 x 158 x 75 mm
  • Voltage: DC 12V
  • Power: 8W
  • Weight: 0.8 kg
  • Capacity: 400 ml
  • Coverage: 500-1000 m³

Replacing Parts

Replace the Atomization Core

The atomization head includes: oil bottle, oil suction pipe, filter, atomization core, regulating valve. Remove the oil bottle, detach the regulating valve and pull out the suction pipe. Remove the old atomization core and insert the new one into the main body of the atomization head. Install the regulating valve. Align the oil suction pipe with the small hole in the atomization core and press firmly.

Diagram Description: A sequence of illustrations showing the disassembly and reassembly of the atomization head, including removing the bottle, separating the spray head, replacing the core and suction pipe, and reattaching the bottle.

Replace the Small Hole Regulating Valve (Reduces Atomization)

Remove the oil bottle, detach the regulating valve, and pull out the suction pipe. Insert the small hole regulating valve into the atomization core, ensuring correct alignment. Align the oil suction pipe with the small hole of the regulating valve and press firmly.

Diagram Description: Illustrations showing the process of replacing the standard regulating valve with a small-hole version, emphasizing correct alignment and reattachment of the suction pipe and bottle.

Equipment Maintenance

If the equipment is not used for a long time, add 95% industrial alcohol to the oil bottle to clean the nozzle and internal parts. It is recommended to maintain the equipment with 95% industrial alcohol every 1-2 months.

Specific Operation: Add 95% industrial alcohol into the empty bottle. Turn on the equipment and run for 10-15 minutes. Turn off the equipment, pour out the alcohol, and screw the bottle back onto the machine.

Warranty Information

  1. The warranty applies to new machines, not resold or second-hand products.
  2. Warranty is valid for 12 months from the purchase date for qualified machines. During this period, repair services and free parts (excluding essential oil) will be provided.
  3. A warranty card and purchase invoice are required for after-service. Contact the manufacturer within the warranty period for any issues.
  4. The following are not covered by the free warranty service:
    • Damage caused by accidents, fire, improper use, or wrong operation.
    • Damage from repairs by unauthorized personnel.
    • Damage during transportation.
    • Missing warranty card.
    • Lack of proper cleaning over time.
    • Exceeding the machine's working time limit.
    • Machines and parts not supplied by the manufacturer.
    • Machines not purchased through official channels.
    • Returning machines without manufacturer's permit.

Notice

  1. Read the instructions carefully before installation and keep the user manual for future reference.
  2. Ensure the machine is upright, with no leaks or tilting, to prevent damage to the device and parts.
  3. Do not use a broken power wire and ensure the power supply is suitable for the machine to prevent fire hazards.
  4. Do not open the machine yourself. Contact customer support promptly if problems arise.
Models: FJ017 Smart Aromatherapy Diffuser, FJ017, Smart Aromatherapy Diffuser, Aromatherapy Diffuser

PDF preview unavailable. Download the PDF instead.

A1 3r3-LdfL Corel PDF Engine Version 22.0.0.412 CorelDRAW 2020