Split-Type Room Air Conditioner

Owner's Manual & Installation Manual

IMPORTANT NOTE

Read this manual and SAFETY MANUAL(if any) carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

Please check the applicable models, technical data, F-GAS(if any) and manufacturer information from the "Owner's Manual - Product Fiche" in the packaging of the outdoor unit (European Union products only) or in the packaging of the indoor unit (model dependent).

Image: A line drawing of a split-type air conditioner indoor unit.

Table of Contents

Safety Precautions ...............................................................................04

Owner's Manual

Unit Specifications and Features...........................................................08

  1. Indoor unit display.........................................................................................................................08
  2. Operating temperature..................................................................................................................09
  3. Other features ..............................................................................................................................10
  4. Setting angle of airflow.................................................................................................................11
  5. Manual operation (without Remote)..............................................................................................11

Care and Maintenance......................................................................12

Troubleshooting.................................................................................14

Installation Manual

Accessories...........................................................................................17

Installation Summary - Indoor Unit ..................................................18

Unit Parts.............................................................................................19

Indoor Unit Installation.......................................................................20

  1. Select installation location..............................................................................................................20
  2. Attach mounting plate to wall........................................................................................................20
  3. Drill wall hole for connective piping................................................................................................21
  4. Prepare refrigerant piping...............................................................................................................22
  5. Connect drain hose........................................................................................................................24
  6. Connect signal and power cables...................................................................................................25
  7. Wrap piping and cables..................................................................................................................26
  8. Mount indoor unit.........................................................................................................................27

Outdoor Unit Installation.........................................................................27

  1. Select installation location..............................................................................................................27
  2. Install drain joint............................................................................................................................28
  3. Anchor outdoor unit......................................................................................................................28
  4. Connect signal and power cables...................................................................................................30

Refrigerant Piping Connection.........................................................31

A. Note on Pipe Length....................................................................................................................31

B. Connection Instructions –Refrigerant Piping.................................................................................31

  1. Cut pipe.................................................................................................................................31
  2. Remove burrs.........................................................................................................................32
  3. Flare pipe ends.......................................................................................................................32
  4. Connect pipes........................................................................................................................32

Air Evacuation...................................................................................34

  1. Evacuation Instructions................................................................................................................34
  2. Note on Adding Refrigerant.........................................................................................................35

Electrical and Gas Leak Checks........................................................36

Test Run.............................................................................................37

Packing and unpacking the unit .....................................................38

Safety Precautions

Read Safety Precautions Before Operation and Installation

Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.

⚠️ WARNING
This symbol indicates the possibility of personnel injury or loss of life.

? CAUTION
This symbol indicates the possibility of property damage or serious consequences.

WARNING

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision (European Union countries).

This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

WARNINGS FOR PRODUCT USE

CLEANING AND MAINTENANCE WARNINGS

CAUTION

ELECTRICAL WARNINGS

TAKE NOTE OF FUSE SPECIFICATIONS

The air conditioner's circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board, such as: T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC, T30A/250VAC, etc.

NOTE: For the units using R32 or R290 refrigerant, only the blast-proof ceramic fuse can be used.

UV-C lamp(Applicable to the unit contains an UV-C lamp only)

This appliance contains a UV-C lamp. Read the maintenance instructions before opening the appliance.

⚠️ WARNING This appliance contains an UV emitter. Do not stare at the light source.

WARNINGS FOR PRODUCT INSTALLATION

Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)

WARNING for Using R32/R290 Refrigerant

European Disposal Guidelines

This marking shown on the product or its literature, indicates that waste electrical and electrical equipment should not be mixed with general household waste.

Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

This appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law requires special collection and treatment. Do not dispose of this product as household waste or unsorted municipal waste.

When disposing of this appliance, you have the following options:

Special notice

Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment. Hazardous substances may leak into the ground water and enter the food chain.

Unit Specifications and Features

Indoor unit display

Image: Diagram showing the indoor unit with labels for Front Panel, Louver, Air Filter (pull up), Power Cable, ECO intelligent eye, Display window, Remote Control, Remote Control Holder. It also shows three display modes (A, B, C) with numbers like "88.8".

"88.8" "88" Displays temperature, operation feature and Error codes:

NOTE: Different models have different front panel and display window. Not all the indicators describing below are available for the air conditioner you purchased. Please check the indoor display window of the unit you purchased. Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.

Operating temperature

When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and cause the unit to disable.

Inverter Split Type
ModeRoom TemperatureOutdoor TemperatureFOR OUTDOOR UNITS WITH BASEPAN HEATER OR CRANKCASE HEATER
COOL mode17°C - 32°C (62°F - 90°F)0°C - 50°C (32°F - 122°F)When outside temperature is below 0°C(32°F), we strongly recommend keeping the unit plugged in at all time to ensure smooth ongoing performance.
HEAT mode0°C - 30°C (32°F - 86°F)-15°C - 50°C (5°F - 122°F) (For models with low temp. cooling systems.)
DRY mode10°C - 32°C (50°F - 90°F)0°C - 52°C (32°F - 126°F) (For special tropical models)
Fixed-speed Type
ModeRoom TemperatureOutdoor Temperature
COOL mode17°C-32°C (62°F-90°F)18°C-43°C (64°F-109°F)
HEAT mode0°C-30°C (32°F-86°F)-7°C-43°C (19°F-109°F) (For models with low-temp cooling systems)
DRY mode10°C-32°C (50°F-90°F)11°C-43°C (52°F-109°F)
18°C-43°C (64°F-109°F)
18°C-52°C (64°F-126°F) (For special tropical models)

NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.

To further optimize the performance of your unit, do the following:

Other Features

Image: Diagram illustrating SLEEP Operation showing temperature changes over time in Cool and Heat modes.

NOTE: For multi-split air conditioners, the following functions are not available: Active clean function, Silence feature, Breeze away function, Refrigerant leakage detection function and Eco feature.

Setting Angle of Air Flow

Setting vertical angle of air flow

While the unit is on, use the SWING button on remote control to set the direction (vertical angle) of airflow. Please refer to the Remote Control Manual for details.

NOTE ON LOUVER ANGLES

When using COOL or DRY mode, do not set louver at too vertical an angle for long periods of time. This can cause water to condense on the louver blade, which will drop on your floor or furnishings. When using COOL or HEAT mode, setting the louver at too vertical an angle can reduce the performance of the unit due to restricted air flow. NOTE: According to the relative standards requirement, please sets the vertical air flow louver to its maximum angle under heating capacity test.

Setting horizontal angle of air flow

The horizontal angle of the airflow must be set manually. Grip the deflector rod (See Fig.B) and manually adjust it to your preferred direction. For some units, the horizontal angle of the airflow can be set by remote control. please refer to the Remote Control Manual.

Image: Diagram showing airflow range and a note about not moving the louver by hand. Fig. A shows the range.

Image: Diagram showing the deflector rod. Fig. B.

Manual Operation (without remote)

? CAUTION

The manual button is intended for testing purposes and emergency operation only. Please do not use this function unless the remote control is lost and it is absolutely necessary. To restore regular operation, use the remote control to activate the unit. Unit must be turned off before manual operation.

To operate your unit manually:

  1. Locate the MANUAL CONTROL button on the right-hand side panel of the unit.
  2. Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
  3. Press the MANUAL CONTROL button again to activate FORCED COOLING mode.
  4. Press the MANUAL CONTROL button a third time to turn the unit off.

Image: Diagram showing the manual control button location. Fig. C.

Care and Maintenance

Cleaning Your Indoor Unit

BEFORE CLEANING OR MAINTENANCE

⚠️ ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY BEFORE CLEANING OR MAINTENANCE.

? CAUTION

Only use a soft, dry cloth to wipe the unit clean. If the unit is especially dirty, you can use a cloth soaked in warm water to wipe it clean.

Cleaning Your Air Filter

A clogged air filter can reduce the cooling efficiency of your unit, can also make the air flow irregular and too much noisy, so please clean the air filter as often as necessary. Once the abnormal noise of air flow is heard, please clean the air filter immediately.

  1. The air filter is on the top of the air conditioner.
  2. Hold both side of the top filter in the place marked with "PULL", then pull it upwards.
  3. If your filter has small air freshening filters, unclip them from the larger filter. Clean these air freshening filters with a hand-held vacuum.
  4. Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
  5. Rinse the filter with fresh water, then shake off excess water.
  6. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
  7. When dry, re-clip the air freshening filter to the larger filter, then install it back on the indoor unit.

Image: Diagram showing how to pull out the air filter.

Image: Diagram showing how to remove and clean air freshening filters.

? CAUTION

Air Filter Reminders (Optional)

Air Filter Cleaning Reminder

After 240 hours of use, the display window on the indoor unit will flash "CL." This is a reminder to clean your filter. After 15 seconds, the unit will revert to its previous display.

To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. If you don't reset the reminder, the "CL" indicator will flash again when you restart the unit.

Air Filter Replacement Reminder

After 2,880 hours of use, the display window on the indoor unit will flash "nF." This is a reminder to replace your filter. After 15 seconds, the unit will revert to its previous display.

To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. If you don't reset the reminder, the "nF" indicator will flash again when you restart the unit.

Maintenance – Long Periods of Non-Use

If you plan not to use your air conditioner for an extended period of time, do the following:

Image: Icons showing: Clean all filters, Turn off unit and disconnect power, Turn on FAN function until unit dries out completely, Remove batteries from remote control.

Maintenance – Pre-Season Inspection

After long periods of non-use, or before periods of frequent use, do the following:

Image: Icons showing: Check for damaged wires, Clean all filters, Check for leaks, Replace batteries, Make sure nothing is blocking all air inlets and outlets.

? CAUTION

Troubleshooting

SAFETY PRECAUTIONS

If ANY of the following conditions occurs, turn off your unit immediately!

DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER IMMEDIATELY!

Common Issues

The following problems are not a malfunction and in most situations will not require repairs.

IssuePossible Causes
Unit does not turn on when pressing ON/OFF buttonThe Unit has a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.
The unit changes from COOL/HEAT mode to FAN modeThe unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previously selected mode again.
The indoor unit emits white mistThe set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctuates again.
Both the indoor and outdoor units emit white mistIn humid regions, a large temperature difference between the room's air and the conditioned air can cause white mist. When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.
The indoor unit makes noisesA rushing air sound may occur when the louver resets its position. A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit's plastic parts.
Both the indoor unit and outdoor unit make noisesLow hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units. Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction. Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.
IssuePossible Causes
The outdoor unit makes noisesThe unit will make different sounds based on its current operating mode.
Dust is emitted from either the indoor or outdoor unitThe unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by covering the unit during long periods of inactivity.
The unit emits a bad odorThe unit may absorb odors from the environment (such as furniture, cooking, cigarettes, etc.) which will be emitted during operations. The unit's filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operateDuring operation, the fan speed is controlled to optimize product operation.
Operation is erratic, unpredictable, or unit is unresponsiveInterference from cell phone towers and remote boosters may cause the unit to malfunction. In this case, try the following:
  • Disconnect the power, then reconnect.
  • Press ON/OFF button on remote control to restart operation.

NOTE: If problem persists, contact a local dealer or your nearest customer service center. Provide them with a detailed description of the unit malfunction as well as your model number.

Troubleshooting

When troubles occur, please check the following points before contacting a repair company.

ProblemPossible CausesSolution
Poor Cooling PerformanceTemperature setting may be higher than ambient room temperatureLower the temperature setting
The heat exchanger on the indoor or outdoor unit is dirtyClean the affected heat exchanger
The air filter is dirtyRemove the filter and clean it according to instructions
The air inlet or outlet of either unit is blockedTurn the unit off, remove the obstruction and turn it back on
Doors and windows are openMake sure that all doors and windows are closed while operating the unit
Excessive heat is generated by sunlightClose windows and curtains during periods of high heat or bright sunshine
Too many sources of heat in the room (people, computers, electronics, etc.)Reduce amount of heat sources
Low refrigerant due to leak or long-term useCheck for leaks, re-seal if necessary and top off refrigerant
SILENCE function is activated (optional function)SILENCE function can lower product performance by reducing operating frequency. Turn off SILENCE function.
ProblemPossible CausesSolution
The unit is not workingPower failureWait for the power to be restored
The power is turned offTurn on the power
The fuse is burned outReplace the fuse
Remote control batteries are deadReplace batteries
The unit starts and stops frequentlyThe Unit's 3-minute protection has been activatedWait three minutes after restarting the unit
Timer is activatedTurn timer off
Poor heating performanceThere's too much or too little refrigerant in the systemCheck for leaks and recharge the system with refrigerant.
Incompressible gas or moisture has entered the system.Evacuate and recharge the system with refrigerant
The compressor is brokenReplace the compressor
The voltage is too high or too lowInstall a manostat to regulate the voltage
The outdoor temperature is extremely lowUse auxiliary heating device
Cold air is entering through doors and windowsMake sure that all doors and windows are closed during use
Low refrigerant due to leak or long-term useCheck for leaks, re-seal if necessary and top off refrigerant
Indicator lamps continue flashingError code appears and begins with the letters as the following in the window display of indoor unit: E(x), P(x), F(x) EH(xx), EL(xx), EC(xx) PH(xx), PL(xx), PC(xx)The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the power and contact your nearest customer service center.

NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center.

Accessories

The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail. The items are not included with the air conditioner must be purchased separately.

Name of AccessoriesQ'ty(pc)ShapeName of AccessoriesQ'ty(pc)Shape
Manual2-3[Manual icon]Remote controller1[Remote icon]
Drain joint (for cooling & heating models)1[Drain joint icon]Battery2[Battery icon]
Seal (for cooling & heating models)1[Seal icon]Remote controller holder(optional)1[Holder icon]
Mounting plate1[Mounting plate icon]Fixing screw for remote controller holder(optional)2[Screw icon]
Anchor5~8 (depending on models)[Anchor icon]Small Filter (Need to be installed on the back of main air filter by the authorized technician while installing the machine)1~2 (depending on models)[Filter icon]
Mounting plate fixing screw5~8 (depending on models)[Screw icon]
NameShapeQuantity(PC)
Connecting pipe assemblyLiquid side: Ø 6.35(1/4in)
Ø 9.52(3/8in)
Ø 9.52(3/8in)
Ø 12.7(1/2in)
Ø 16(5/8in)
Ø 19(3/4in)
Gas side:
Parts you must purchase separately. Consult the dealer about the proper pipe size of the unit you purchased.
Magnetic ring and belt (if supplied, please refer to the wiring diagram to install it on the connective cable.)[Magnetic ring and belt icon]Varies by model

Image: Diagram showing how to install magnetic ring and belt.

Installation Summary - Indoor Unit

Image: A step-by-step visual guide for indoor unit installation with 9 steps, each with a small diagram: 1. Select Installation Location, 2. Determine Wall Hole Position, 3. Attach Mounting Plate, 4. Drill Wall Hole, 5. Connect Piping, 6. Connect Wiring, 7. Prepare Drain Hose, 8. Wrap Piping and Cable, 9. Mount Indoor Unit. The diagrams show clearances and basic actions.

Unit Parts

NOTE: The installation must be performed in accordance with the requirement of local and national standards. The installation may be slightly different in different areas.

Image: Two diagrams showing the indoor and outdoor units with various parts labeled with numbers (1-11).

List of Parts:

  1. Wall Mounting Plate
  2. Front Panel
  3. Power Cable (Some Units)
  4. Louver
  5. Air filter (pull it out)
  6. Drainage Pipe
  7. Signal Cable
  8. Refrigerant Piping
  9. Remote Controller
  10. Remote Controller Holder (Some Units)
  11. Outdoor Unit Power Cable (Some Units)

Note on Illustrations: Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.

Indoor Unit Installation

Installation Instructions – Indoor unit

PRIOR TO INSTALLATION

Before installing the indoor unit, refer to the label on the product box to make sure that the model number of the indoor unit matches the model number of the outdoor unit.

Step 1: Select installation location

Before installing the indoor unit, you must choose an appropriate location. The following are standards that will help you choose an appropriate location for the unit.

Proper installation locations meet the following standards:

DO NOT install unit in the following locations:

NOTE ABOUT WALL HOLE:

If there is no fixed refrigerant piping: While choosing a location, be aware that you should leave ample room for a wall hole (see Drill wall hole for connective piping step) for the signal cable and refrigerant piping that connect the indoor and outdoor units. The default position for all piping is the right side of the indoor unit (while facing the unit). However, the unit can accommodate piping to both the left and right.

Image: Diagram showing proper distance from walls and ceiling for indoor unit installation, with measurements (12cm, 2.3m).

Note:

Step 2: Attach mounting plate to wall

The mounting plate is the device on which you will mount the indoor unit.

Image: Diagram showing screw removal for mounting plate.

NOTE FOR CONCRETE OR BRICK WALLS:

If the wall is made of brick, concrete, or similar material, drill 5mm-diameter (0.2in-diameter) holes in the wall and insert the sleeve anchors provided. Then secure the mounting plate to the wall by tightening the screws directly into the clip anchors.

Step 3: Drill wall hole for connective piping
  1. Determine the location of the wall hole based on the position of the mounting plate. Refer to Mounting Plate Dimensions.
  2. Using a 65mm (2.5in) or 90mm(3.54in) (depending on models) core drill, drill a hole in the wall. Make sure that the hole is drilled at a slight downward angle, so that the outdoor end of the hole is lower than the indoor end by about 5mm to 7mm (0.2-0.275in). This will ensure proper water drainage.

Image: Diagram showing the wall hole drilling process, including indoor/outdoor perspective, angle, and dimensions. It also shows a bubble level on the mounting plate.

? CAUTION The Bubble level on the mounting plate can't be removed. If it is broken, make sure to clean up the leaking liquid.

Note: When the gas side connective pipe is Ø 16mm(5/8in) or more, the wall hole should be 90mm(3.54in).

  1. Place the protective wall cuff in the hole. This protects the edges of the hole and will help seal it when you finish the installation process.

? CAUTION When drilling the wall hole, make sure to avoid wires, plumbing, and other sensitive components.

MOUNTING PLATE DIMENSIONS

Different models have different mounting plates. For the convenience of installation, there are bubble level, carved dimensions on the mounting plate. Please install the plate and drill wall hole according to the information of the mounting plate. See the figures below.

Image: Diagrams showing correct orientation of Mounting Plate and dimensions for Model A, Model B, and Model C, including pipe hole sizes and edge-to-center measurements.

Step 4: Prepare refrigerant piping

The refrigerant piping is inside an insulating sleeve attached to the back of the unit. You must prepare the piping before passing it through the hole in the wall. Refer to the Refrigerant Piping Connection section of this manual for detailed instructions on pipe flaring and flare torque requirements, technique, etc.

NOTE ON PIPING ANGLE

Refrigerant piping can exit the indoor unit from four different angles:

Refer to figures below for details.

Image: Diagrams showing the four possible angles for refrigerant piping exit.

If refrigerant piping is already embedded in the wall, do the following:

Step 1: Hook the indoor unit on the mounting plate:
  1. Keep in mind that the hooks on the mounting plate are smaller than the holes on the back of the unit. If you find that you don't have ample room to connect embedded pipes to the indoor unit, the unit can be adjusted left or right by about 30-50mm (1.18-1.95in), depending on the model.

Image: Diagram showing adjustment range for the indoor unit.

Step 2: Prepare refrigerant piping:
  1. Open and fix the position of the panel, then, open the covers of the two lock blocks, unscrew the screw showed in the picture below, then hold both sides of the lower panel in the place marked "PULL", pull it upwards to release the buckles, then take the lower panel down.

Image: Diagram showing how to open the panel and unscrew the screw. Model A shown.

Image: Diagram showing how to open the cover and unscrew screws, and how to pull the lower panel. Model B shown.

NOTE ON PIPING CONNECTING

In some locations of US, a conduit tube must be used to connect the cable. To ensure an enough space for the pipes running and the machine is against the wall after installation, It is recommended to attach the drain hose to the right-hand side (when you're facing the back of the unit). When choose Left-hand side or Right-hand side piping, please make sure that the pipes come out horizontally so as not to affect the lower panel installation.

? CAUTION Be extremely careful not to dent or damage the piping while bending them away from the unit. Any dents in the piping will affect the unit's performance.

If there is no refrigerant piping embedded in the wall, do the following:

  1. Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit.
  2. If the wall hole is behind the unit, keep the knock-out panel in place. If the wall hole is to the side of the indoor unit, remove the plastic knock-out panel from that side of the unit. (See figure below). This will create a slot through which your piping can exit the unit. Use needle nose pliers if the plastic panel is too difficult to remove by hand.

Image: Diagram showing knock-out panel removal.

  1. Use the holder at the back of the unit to prop up the unit, giving you enough room to connect the refrigerant piping, signal cable, and drain hose.

Image: Diagram showing how to use the holder to prop up the unit.

Step 3. Connect drain hose and refrigerant piping (refer to Refrigerant Piping Connection section of this manual for instructions).

Step 4. Keep pipe connection point exposed to perform the leak test (refer to Electrical Checks and Leak Checks section of this manual).

Step 5. After the leak test, wrap the connection point with insulation tape.

Step 6. Remove the bracket or wedge that is propping with insulation tape.

Step 7. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate.

Image: Diagram showing cutting the insulating sleeve.

  1. Use scissors to cut down the length of the insulating sleeve to reveal about 40mm (1.57in) of the refrigerant piping. This serves two purposes:
    • To facilitate the Refrigerant Piping Connection process.
    • To facilitate Gas Leak Checks and enable you to check for dents.
  2. Use the holder at the back of the unit to prop up the unit, giving you enough room to connect the refrigerant piping, signal cable, and drain hose.
  3. Connect the indoor unit's refrigerant piping to the connective piping that will join the indoor and outdoor units. Refer to the Refrigerant Piping Connection section of this manual for detailed instructions.
  4. Based on the position of the wall hole relative to the mounting plate, determine the necessary angle of your piping.
  5. Grip the refrigerant piping at the base of the bend.
  6. Slowly, with even pressure, bend the piping towards the hole. Do not dent or damage the piping during the process.
Step 5: Connect drain hose

By default, the drain hose is attached to the left-hand side of unit (when you're facing the back of the unit). However, it can also be attached to the right-hand side. To ensure proper drainage, attach the drain hose on the same side that your refrigerant piping exits the unit.

Note: In some locations of US, if the machine has installed the conduit panel, please choose right-hand side drainage.

NOTE ON DRAIN HOSE PLACEMENT

Make sure to arrange the drain hose according to the following figures.

Image: Diagrams showing CORRECT and NOT CORRECT drain hose placement.

Image: Diagram showing how to plug the unused drain hole.

BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS

⚠️ BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.

Step 6: Connect signal and power cables

The signal cable enables communication between the indoor and outdoor units. You must first choose the right cable size before preparing it for connection.

Cable Types:

Note: In North America, choose the cable type according to the local electrical codes and regulations.

Rated Current of Appliance (A)Nominal Cross-Sectional Area (mm²)
> 3 and ≤ 60.75
> 6 and ≤ 101
> 10 and ≤ 161.5
> 16 and ≤ 252.5
> 25 and ≤ 324
> 32 and ≤ 406

⚠️ ALL WIRING MUST BE PERFORMED STRICTLY IN ACCORDANCE WITH THE WIRING DIAGRAM LOCATED ON THE BACK OF THE INDOOR UNIT'S FRONT PANEL.

  1. Feed the signal wire through this slot, from the back of the unit to the front.
  2. Facing the front of the unit, connect the wire according to the indoor unit's wiring diagram, connect the u-lug and firmly screw each wire to its corresponding terminal.

Image: Diagram showing opening the front panel, removing the lower panel, and accessing the terminal block.

CHOOSE THE RIGHT CABLE SIZE

The size of the power supply cable, signal cable, fuse, and switch needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the side panel of the unit. Refer to this nameplate to choose the right cable, fuse, or switch.

Note: In North America, please choose the right cable size according to the Minimum Circuit Ampacity indicated on the nameplate of the unit.

  1. Open and fix the position of the panel, then, open the covers of the two lock blocks, unscrew the screw, then hold both sides of the lower panel in the place marked "PULL", pull it upwards to release the buckles, then take the lower panel down (please refer to Page 22-23).
  2. Open the wire box cover to connect the cable.
  3. Unscrew the cable clamp below the terminal block and place it to the side.
  4. Facing the back of the unit, remove the plastic panel on the bottom left-hand side.

Image: Diagram showing terminal block, cable clamp, rat baffle, and knock-out panel.

Note: If the size of the cable is too big, remove the middle small plastic knock-out panel to create a slot through which the cable can exit. If you want to remove the chassis or drain hose, please remove the rat baffle first.

In North America:

  1. Remove the knock-out panel to create a slot through which the conduit tube can install. Then make the cable through the conduit tube and connect to the indoor unit.

? CAUTION DO NOT MIX UP LIVE AND NULL WIRES. This is dangerous, and can cause the air conditioning unit to malfunction.

  1. After checking to make sure every connection is secure, use the cable clamp to fasten the signal cable to the unit. Screw the cable clamp down tightly.
  2. Replace the wire cover on the front of the unit, and the plastic panel on the back.

NOTE ABOUT WIRING

THE WIRING CONNECTION PROCESS MAY DIFFER SLIGHTLY BETWEEN UNITS AND REGIONS.

Step 7: Wrapping and cables

Before passing the piping, drain hose, and the signal cable through the wall hole, you must bundle them together to save space, protect them, and insulate them (This may not applicable for some locations in US).

  1. Bundle the drain hose, refrigerant pipes, and signal cable as shown below:

Image: Diagram showing how to bundle the drain hose, refrigerant pipes, and signal cable, with labels like "Indoor Unit", "Space behind unit", "Refrigerant piping", "Insulation tape", "Signal wire", "Drain hose".

DRAIN HOSE MUST BE ON BOTTOM Make sure that the drain hose is at the bottom of the bundle. Putting the drain hose at the top of the bundle can cause the drain pan to overflow, which can lead to fire or water damage.

DO NOT INTERTWINE SIGNAL CABLE WITH OTHER WIRES While bundling these items together, do not intertwine or cross the signal cable with any other wiring.

  1. Using adhesive vinyl tape, attach the drain hose to the underside of the refrigerant pipes.
  2. Using insulation tape, wrap the signal wire, refrigerant pipes, and drain hose tightly together. Double-check that all items are bundled.

DO NOT WRAP ENDS OF PIPING When wrapping the bundle, keep the ends of the piping unwrapped. You need to access them to test for leaks at the end of the installation process (refer to Electrical Checks and Leak Checks section of this manual).

Step 8: Mount indoor unit

If you installed new connective piping to the outdoor unit, do the following:

  1. If you have already passed the refrigerant piping through the hole in the wall, proceed to Step 4.
  2. Otherwise, double-check that the ends of the refrigerant pipes are sealed to prevent dirt or foreign materials from entering the pipes.
  3. Slowly pass the wrapped bundle of refrigerant pipes, drain hose, and signal wire through the hole in the wall.
  4. Hook the top of the indoor unit on the upper hook of the mounting plate.
  5. Check that unit is hooked firmly on mounting by applying slight pressure to the left and right-hand sides of the unit. The unit should not jiggle or shift.
  6. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate.
  7. Again, check that the unit is firmly mounted by applying slight pressure to the left and the right-hand sides of the unit.

Outdoor Unit Installation

Install the unit by following local codes and regulations, there may be differ slightly between different regions.

Image: Diagram showing recommended clearances for the outdoor unit (30cm left, 60cm above, 200cm front, 30cm back, 60cm right).

Installation Instructions – Outdoor unit

Step 1: Select installation location

Before installing the outdoor unit, you must choose an appropriate location. The following are standards that will help you choose an appropriate location for the unit.

Proper installation locations meet the following standards:

DO NOT install unit in the following locations:

SPECIAL CONSIDERATIONS FOR EXTREME WEATHER

If the unit is exposed to heavy wind:

Install unit so that air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier in front of the unit to protect it from extremely heavy winds. See Figures below.

Image: Diagrams showing wind direction and a wind baffle.

If the unit is frequently exposed to heavy rain or snow:

Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air flow around the unit.

If the unit is frequently exposed to salty air (seaside):

Use outdoor unit that is specially designed to resist corrosion.

Step 2: Install drain joint (Heat pump unit only)

Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. Note that there are two different types of drain joints depending on the type of outdoor unit.

If the drain joint comes with a rubber seal (see Fig. A), do the following:

  1. Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit.
  2. Insert the drain joint into the hole in the base pan of the unit.
  3. Rotate the drain joint 90° until it clicks in place facing the front of the unit.
  4. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during heating mode.

If the drain joint doesn't come with a rubber seal (see Fig. B), do the following:

  1. Insert the drain joint into the hole in the base pan of the unit. The drain joint will click in place.
  2. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during heating mode.

Image: Diagrams showing drain joint types A (with seal) and B (without seal), and the base pan hole.

IN COLD CLIMATES

In cold climates, make sure that the drain hose is as vertical as possible to ensure swift water drainage. If water drains too slowly, it can freeze in the hose and flood the unit.

Step 3: Anchor outdoor unit

The outdoor unit can be anchored to the ground or to a wall-mounted bracket with bolt(M10). Prepare the installation base of the unit according to the dimensions below.

UNIT MOUNTING DIMENSIONS

The following is a list of different outdoor unit sizes and the distance between their mounting feet. Prepare the installation base of the unit according to the dimensions below.

Image: Diagram showing outdoor unit dimensions (A, B, H, W) and air inlet/outlet.

Outdoor Unit Dimensions (mm) W x H x DMounting Dimensions
Distance A (mm)Distance B (mm)
681x434x285 (26.8"x 17.1"x 11.2")460 (18.1")292 (11.5")
700x550x270 (27.5"x 21.6"x 10.6")450 (17.7")260 (10.2")
700x550x275 (27.5"x 21.6"x 10.8")450 (17.7")260 (10.2")
720x495x270 (28.3"x 19.5"x 10.6")452 (17.8")255 (10.0")
728x555x300 (28.7"x 21.8"x 11.8")452 (17.8")302(11.9")
765x555x303 (30.1"x 21.8"x 11.9")452 (17.8")286(11.3")
770x555x300 (30.3"x 21.8"x 11.8")487 (19.2")298 (11.7")
805x554x330 (31.7"x 21.8"x 12.9")511 (20.1")317 (12.5")
800x554x333 (31.5"x 21.8"x 13.1")514 (20.2")340 (13.4")
845x702x363 (33.3"x 27.6"x 14.3")540 (21.3")350 (13.8")
890x673x342 (35.0"x 26.5"x 13.5")663 (26.1")354 (13.9")
946x810x420 (37.2"x 31.9"x 16.5")673 (26.5")403 (15.9")
946x810x410 (37.2"x 31.9"x 16.1")673 (26.5")403 (15.9")

If you will install the unit on the ground or on a concrete mounting platform, do the following:

  1. Mark the positions for four expansion bolts based on dimensions chart.
  2. Pre-drill holes for expansion bolts.
  3. Place a nut on the end of each expansion bolt.
  4. Hammer expansion bolts into the pre-drilled holes.
  5. Remove the nuts from expansion bolts, and place outdoor unit on bolts.
  6. Put washer on each expansion bolt, then replace the nuts.
  7. Using a wrench, tighten each nut until snug.

⚠️ WHEN DRILLING INTO CONCRETE, EYE PROTECTION IS RECOMMENDED AT ALL TIMES.

If you will install the unit on a wall-mounted bracket, do the following:

? CAUTION Make sure that the wall is made of solid brick, concrete, or of similarly strong material. The wall must be able to support at least four times the weight of the unit.

  1. Mark the position of bracket holes based on dimensions chart.
  2. Pre-drill the holes for the expansion bolts.
  3. Place a washer and nut on the end of each expansion bolt.
  4. Thread expansion bolts through holes in mounting brackets, put mounting brackets in position, and hammer expansion bolts into the wall.
  5. Check that the mounting brackets are level.
  6. Carefully lift unit and place its mounting feet on brackets.
  7. Bolt the unit firmly to the brackets.
  8. If allowed, install the unit with rubber gaskets to reduce vibrations and noise.

Step 4: Connect signal and power cables

The outside unit's terminal block is protected by an electrical wiring cover on the side of the unit. A comprehensive wiring diagram is printed on the inside of the wiring cover.

⚠️ BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.

  1. Prepare the cable for connection:
    • USE THE RIGHT CABLE: Please choose the right cable refer to "Cable types" in page 25.
    • CHOOSE THE RIGHT CABLE SIZE: The size of the power supply cable, signal cable, fuse, and switch needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the side panel of the unit. Note: In North America, please choose the right cable size according to the Minimum Circuit Ampacity indicated on the nameplate of the unit.
    • a. Using wire strippers, strip the rubber jacket from both ends of cable to reveal about 40mm (1.57in) of the wires inside.
    • b. Strip the insulation from the ends of the wires.
    • c. Using a wire crimper, crimp u-lugs on the ends of the wires.
    • PAY ATTENTION TO LIVE WIRE: While crimping wires, make sure you clearly distinguish the Live (“L”) Wire from other wires.

⚠️ ALL WIRING WORK MUST BE PERFORMED STRICTLY IN ACCORDANCE WITH THE WIRING DIAGRAM LOCATED INSIDE OF WIRE COVER OF THE OUTDOOR UNIT.

  1. Unscrew the electrical wiring cover and remove it.
  2. Unscrew the cable clamp below the terminal block and place it to the side.
  3. Connect the wire according to the wiring diagram, and firmly screw the u-lug of each wire to its corresponding terminal.
  4. After checking to make sure every connection is secure, loop the wires around to prevent rain water from flowing into the terminal.
  5. Using the cable clamp, fasten the cable to the unit. Screw the cable clamp down tightly.
  6. Insulate unused wires with PVC electrical tape. Arrange them so that they do not touch any electrical or metal parts.
  7. Replace the wire cover on the front of the unit, and the plastic panel on the back.

Image: Diagram showing the wire cover, terminal block, cable clamp, and the correct way to select the through-hole for the wire diameter. Also shows a buckle for clamping.

In North America:

  1. Remove the wire cover from the unit by loosening the 3 screws.
  2. Dismount caps on the conduit panel.
  3. Temporarily mount the conduit tubes (not included) on the conduit panel.
  4. Properly connect both the power supply and low voltage lines to the corresponding terminals on the terminal block.
  5. Ground the unit in accordance with local codes.
  6. Be sure to size each wire allowing several inches longer than the required length for wiring.
  7. Use lock nuts to secure the conduit tubes.

Refrigerant Piping Connection

When connecting refrigerant piping, do not let substances or gases other than the specified refrigerant enter the unit. The presence of other gases or substances will lower the unit's capacity, and can cause abnormally high pressure in the refrigeration cycle. This can cause explosion and injury.

Note on Pipe Length

The length of refrigerant piping will affect the performance and energy efficiency of the unit. Nominal efficiency is tested on units with a pipe length of 5 meters (16.5ft) (In North America, the standard pipe length is 7.5m (25'). A minimum pipe run of 3 metres is required to minimise vibration & excessive noise. In special tropical area, for the R290 refrigerant models, no refrigerant can be added and the maximum length of refrigerant pipe should not exceed 10 meters(32.8ft).

Refer to the table below for specifications on the maximum length and drop height of piping.

ModelCapacity (BTU/h)Max. Length (m)Max. Drop Height (m)
R410A, R32 Inverter Split Air Conditioner< 15,00025 (82ft)10 (33ft)
≥ 15,000 and < 24,00030 (98.5ft)20 (66ft)
≥ 24,000 and < 36,00050 (164ft)25 (82ft)
R22 Fixed-speed Split Air Conditioner< 18,00010 (33ft)5 (16ft)
> 18,000 and < 21,00015 (49ft)8(26ft)
≥ 21,000 and < 35,00020 (66ft)10(33ft)
R410A, R32 Fixed-speed Split Air Conditioner< 18,00020 (66ft)8(26ft)
≥ 18,000 and < 36,00025 (82ft)10(33ft)

Connection Instructions – Refrigerant Piping

Step 1: Cut pipes

When preparing refrigerant pipes, take extra care to cut and flare them properly. This will ensure efficient operation and minimize the need for future maintenance.

  1. Measure the distance between the indoor and outdoor units.
  2. Using a pipe cutter, cut the pipe a little longer than the measured distance.
  3. Make sure that the pipe is cut at a perfect 90° angle.

Image: Diagram showing correct (90°) and incorrect (oblique, rough, warped) pipe cutting.

DO NOT DEFORM PIPE WHILE CUTTING Be extra careful not to damage, dent, or deform the pipe while cutting. This will drastically reduce the heating efficiency of the unit.

Step 2: Remove burrs

Burrs can affect the air-tight seal of refrigerant piping connection. They must be completely removed.

  1. Hold the pipe at a downward angle to prevent burrs from falling into the pipe.
  2. Using a reamer or deburring tool, remove all burrs from the cut section of the pipe.

Image: Diagram showing pipe and reamer.

Outer Diameter of Pipe (mm)A (mm)
Min.Max.
Ø 6.35 (Ø 0.25″)0.7 (0.0275″)1.3 (0.05″)
Ø 9.52 (Ø 0.375″)1.0 (0.04″)1.6 (0.063″)
Ø 12.7 (Ø 0.5″)1.0 (0.04″)1.8 (0.07″)
Ø 16 (Ø 0.63″)2.0 (0.078″)2.2 (0.086″)
Ø 19 (Ø 0.75″)2.0 (0.078″)2.4 (0.094″)

Image: Diagram showing flare form and pipe extension 'A'.

Step 3: Flare pipe ends

Proper flaring is essential to achieve an airtight seal.

  1. After removing burrs from cut pipe, seal the ends with PVC tape to prevent foreign materials from entering the pipe.
  2. Sheath the pipe with insulating material.
  3. Place flare nuts on both ends of pipe. Make sure they are facing in the right direction, because you can't put them on or change their direction after flaring.

Image: Diagram showing flare nut and copper pipe.

  1. Remove PVC tape from ends of pipe when ready to perform flaring work.
  2. Clamp flare form on the end of the pipe. The end of the pipe must extend beyond the edge of the flare form in accordance with the dimensions shown in the table below.
  3. Place flaring tool onto the form.
  4. Turn the handle of the flaring tool clockwise until the pipe is fully flared.
  5. Remove the flaring tool and flare form, then inspect the end of the pipe for cracks and even flaring.
Step 4: Connect pipes

When connecting refrigerant pipes, be careful not to use excessive torque or to deform the piping in any way. You should first connect the low-pressure pipe, then the high-pressure pipe.

MINIMUM BEND RADIUS

When bending connective refrigerant piping, the minimum bending radius is 10cm.

Image: Diagram showing minimum bend radius.

Instructions for Connecting Piping to Indoor Unit

  1. Align the center of the two pipes that you will connect.

Image: Diagram showing alignment of indoor unit tubing and pipe flare nut.

  1. Tighten the flare nut as tightly as possible by hand.
  2. Using a spanner, grip the nut on the unit tubing.
  3. While firmly gripping the nut on the unit tubing, use a torque wrench to tighten the flare nut according to the torque values in the Torque Requirements table below. Loosen the flaring nut slightly, then tighten again.
Outer Diameter of Pipe (mm)Tightening Torque (N·m)Flare dimension(B) (mm)Flare shape
Ø 6.35 (Ø 0.25″)18~20(180~200kgf.cm)8.4~8.7 (0.33~0.34″)90 ±4
Ø 9.52 (Ø 0.375″)32~39(320~390kgf.cm)13.2~13.5 (0.52~0.53″)45 ±2
Ø 12.7 (Ø 0.5″)49~59(490~590kgf.cm)16.2~16.5 (0.64~0.65″)B R0.4~0.8
Ø 16 (Ø 0.63″)57~71(570~710kgf.cm)19.2~19.7 (0.76~0.78″)
Ø 19 (Ø 0.75″)67~101(670~1010kgf.cm)23.2~23.7 (0.91~0.93″)

DO NOT USE EXCESSIVE TORQUE Excessive force can break the nut or damage the refrigerant piping. You must not exceed torque requirements shown in the table above.

Instructions for Connecting Piping to Outdoor Unit

  1. Unscrew the cover from the packed valve on the side of the outdoor unit.
  2. Remove protective caps from ends of valves.
  3. Align flared pipe end with each valve, and tighten the flare nut as tightly as possible by hand.
  4. Using a spanner, grip the body of the valve. Do not grip the nut that seals the service valve.

USE SPANNER TO GRIP MAIN BODY OF VALVE Torque from tightening the flare nut can snap off other parts of valve.

  1. While firmly gripping the body of the valve, use a torque wrench to tighten the flare nut according to the correct torque values.
  2. Loosen the flaring nut slightly, then tighten again.
  3. Repeat Steps 3 to 6 for the remaining pipe.

Air Evacuation

Preparations and Precautions

Air and foreign matter in the refrigerant circuit can cause abnormal rises in pressure, which can damage the air conditioner, reduce its efficiency, and cause injury. Use a vacuum pump and manifold gauge to evacuate the refrigerant circuit, removing any non-condensable gas and moisture from the system. Evacuation should be performed upon initial installation and when unit is relocated.

BEFORE PERFORMING EVACUATION

Evacuation Instructions

  1. Connect the charge hose of the manifold gauge to service port on the outdoor unit's low pressure valve.
  2. Connect another charge hose from the manifold gauge to the vacuum pump.
  3. Open the Low Pressure side of the manifold gauge. Keep the High Pressure side closed.
  4. Turn on the vacuum pump to evacuate the system.
  5. Run the vacuum for at least 15 minutes, or until the Compound Meter reads -76cmHG (-105Pa).

Image: Diagram showing the Manifold Gauge setup with vacuum pump, pressure hose, charge hose, low pressure valve, high pressure valve, and compound gauge.

  1. If there is a change in system pressure, refer to Gas Leak Check section for information on how to check for leaks. If there is no change in system pressure, unscrew the cap from the packed valve (high pressure valve).
  2. Insert hexagonal wrench into the packed valve (high pressure valve) and open the valve by turning the wrench in a 1/4 counterclockwise turn. Listen for gas to exit the system, then close the valve after 5 seconds.
  3. Watch the Pressure Gauge for one minute to make sure that there is no change in pressure. The Pressure Gauge should read slightly higher than atmospheric pressure.
  4. Remove the charge hose from the service port.

Image: Diagram showing valve body, valve stem, cap, and flare nut.

  1. Using hexagonal wrench, fully open both the high pressure and low pressure valves.
  2. Tighten valve caps on all three valves (service port, high pressure, low pressure) by hand. You may tighten it further using a torque wrench if needed.

OPEN VALVE STEMS GENTLY When opening valve stems, turn the hexagonal wrench until it hits against the stopper. Do not try to force the valve to open further.

  1. Close the Low Pressure side of the manifold gauge, and turn off the vacuum pump.
  2. Wait for 5 minutes, then check that there has been no change in system pressure.

Note on Adding Refrigerant

Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 7.5m (25'). In other areas, the standard pipe length is 5m (16'). The refrigerant should be charged from the service port on the outdoor unit's low pressure valve. The additional refrigerant to be charged can be calculated using the following formula:

Connective Pipe Length (m)Air Purging MethodAdditional Refrigerant
< Standard pipe lengthVacuum PumpLiquid Side: Ø 6.35 (Ø 0.25″)
R32: (Pipe length - standard length) x 12g/m (Pipe length - standard length) x 0.13oZ/ft
R290: (Pipe length - standard length) x 10g/m (Pipe length - standard length) x 0.10oZ/ft
R410A: (Pipe length - standard length) x 15g/m (Pipe length - standard length) x 0.16oZ/ft
R22: (Pipe length - standard length) x 20g/m (Pipe length - standard length) x 0.21oZ/ft
Liquid Side: Ø 9.52 (ø 0.375″)
R32: (Pipe length - standard length) x 24g/m (Pipe length - standard length) x 0.26oZ/ft
R290: (Pipe length - standard length) x 18g/m (Pipe length - standard length) x 0.19oZ/ft
R410A: (Pipe length - standard length) x 30g/m (Pipe length - standard length) x 0.32oZ/ft
R22: (Pipe length - standard length) x 40g/m (Pipe length - standard length) x 0.42oZ/ft
> Standard pipe lengthVacuum PumpN/A

For R290 refrigerant unit, the total amount of refrigerant to be charged is no more than: 387g(<=9000Btu/h), 447g(>9000Btu/h and <=12000Btu/h), 547g(>12000Btu/h and <=18000Btu/h), 632g(>18000Btu/h and <=24000Btu/h).

? CAUTION DO NOT mix refrigerant types.

Electrical and Gas Leak Checks

Before Test Run

Only perform test run after you have completed the following steps:

Electrical Safety Checks

After installation, confirm that all electrical wiring is installed in accordance with local and national regulations, and according to the Installation Manual.

BEFORE TEST RUN

⚠️ RISK OF ELECTRIC SHOCK. ALL WIRING MUST COMPLY WITH LOCAL AND NATIONAL ELECTRICAL CODES, AND MUST BE INSTALLED BY A LICENSED ELECTRICIAN.

Check Grounding Work

Measure grounding resistance by visual detection and with grounding resistance tester. Grounding resistance must be less than 0.1Ω.

Note: This may not be required for some locations in North America.

DURING TEST RUN

Check for Electrical Leakage

During the Test Run, use an electroprobe and multimeter to perform a comprehensive electrical leakage test. If electrical leakage is detected, turn off the unit immediately and call a licensed electrician to find and resolve the cause of the leakage.

Note: This may not be required for some locations in North America.

Gas Leak Checks

There are two different methods to check for gas leaks.

Soap and Water Method

Using a soft brush, apply soapy water or liquid detergent to all pipe connection points on the indoor unit and outdoor unit. The presence of bubbles indicates a leak.

Leak Detector Method

If using leak detector, refer to the device's operation manual for proper usage instructions.

AFTER PERFORMING GAS LEAK CHECKS

After confirming that the all pipe connection points DO NOT leak, replace the valve cover on the outside unit.

Image: Diagram showing check-points for indoor and outdoor units (A, B, C, D). A: Low pressure stop valve, B: High pressure stop valve, C & D: Indoor unit flare nuts.

Test Run

Test Run Instructions

You should perform the Test Run for at least 30 minutes.

  1. Connect power to the unit.
  2. Press the ON/OFF button on the remote controller to turn it on.
  3. Press the MODE button to scroll through the following functions, one at a time:
    • COOL – Select lowest possible temperature
    • HEAT – Select highest possible temperature
  4. Let each function run for 5 minutes, and perform the following checks:
Check ItemPASS/FAIL
No electrical leakage
Unit is properly grounded
All electrical terminals properly covered
Indoor and outdoor units are solidly installed
All pipe connection points do not leakOutdoor (2):Indoor (2):
Water drains properly from drain hose
All piping is properly insulated
Unit performs COOL function properly
Unit performs HEAT function properly
Indoor unit louvers rotate properly
Indoor unit responds to remote controller

DOUBLE-CHECK PIPE CONNECTIONS

During operation, the pressure of the refrigerant circuit will increase. This may reveal leaks that were not present during your initial leak check. Take time during the Test Run to double-check that all refrigerant pipe connection points do not have leaks. Refer to Gas Leak Check section for instructions.

  1. After the Test Run is successfully completed, and you confirm that all checks points in List of Checks to Perform have PASSED, do the following:
    • Using remote control, return unit to normal operating temperature.
    • Using insulation tape, wrap the indoor refrigerant pipe connections that you left uncovered during the indoor unit installation process.

IF AMBIENT TEMPERATURE IS BELOW 17°C (62°F)

You can't use the remote controller to turn on the COOL function when the ambient temperature is below 16°C. In this instance, you can use the MANUAL CONTROL button to test the COOL function.

  1. The MANUAL CONTROL button is located on the right-hand side panel of the unit.
  2. Press the button 2 times to select the COOL function.
  3. Perform Test Run as normal.

Image: Diagram showing the manual control button.

Packing and unpacking the unit

Instructions for packing and unpacking the unit:

Unpacking: Indoor unit:
  1. Cut the sealing tape on the carton with a knife, one cut on the left, one cut in the middle and one cut on the right.
  2. Use the vice to take out the sealing nails on the top of the carton.
  3. Open the carton.
  4. Take out the middle support plate if it is included.
  5. Take out the accessory package, and take out the connecting wire if it is included.
  6. Lift the machine out of the carton and lay it flat.
  7. Remove the left and right package foam or the upper and lower packaging foam, untie the packaging bag.
Outdoor Unit
  1. Cut the packing belt.
  2. Take the unit out of the carton.
  3. Remove the foam from the unit.
  4. Remove the packaging bag from the unit.
Packing: Indoor unit:
  1. Put the indoor unit into the packing bag.
  2. Attach the left and right package foam or the upper and lower packaging foam to the unit.
  3. Put the unit into the carton, then put accessory package in.
  4. Close the carton and seal it with the tape.
  5. Using the packing belt if necessary.
Outdoor unit:
  1. Put the outdoor unit into the packing bag.
  2. Put the bottom foam into the box.
  3. Put the unit into the carton, then put the upper packaging foam on the unit.
  4. Close the carton and seal it with the tape.
  5. Using the packing belt if necessary.

Note: Please keep all packaging items if you may need in the future.

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.

CS014UI-EP(B)
16122000009397
20210719

Models: MSEPCU-18HRFN8, MOX430-18HFN8, 18HFN8 Series Split Type Room Air Conditioner, 18HFN8 Series, Split Type Room Air Conditioner, Type Room Air Conditioner, Room Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 41 Pages, 3.74MB

PDF preview unavailable. Download the PDF instead.

manual-utilizare-aer-conditionat-midea-all-easy-pro-nordic-12000-btu-msepbu-12hrfn8-mox330-12hfn8

References

iLovePDF

Related Documents

PreviewMidea Inverter Air Conditioner User Manual
User manual for Midea Inverter One-Two/One-Three/One-Four/One-Five/One-Six Split-Type Air Conditioner, covering installation, operation, maintenance, and troubleshooting.
PreviewMidea Window-Type Room Air Conditioner Owner's Manual & Installation Manual
This manual provides comprehensive instructions for the operation, care, maintenance, and installation of Midea window-type room air conditioners. It includes safety precautions, troubleshooting tips, and specifications.
PreviewMidea Portable Air Conditioner Owner's Manual & Installation Guide
Comprehensive owner's and installation manual for Midea portable air conditioners, models MPPD33CB and MPPD33HB. Includes safety precautions, installation instructions, operating guidelines, maintenance tips, and troubleshooting.
PreviewMidea Portable Air Conditioner Owner's Manual & Installation Guide
Comprehensive guide for Midea portable air conditioners, covering safety precautions, installation instructions, operating procedures, maintenance, and troubleshooting for models like MPPH-08CRN7-QB6 and MPPH-09CRN7-QB6G1.
PreviewMidea Split-Type Room Air Conditioner: Owner's Manual & Installation Guide
Comprehensive guide for Midea split-type room air conditioners, covering installation, operation, safety precautions, maintenance, troubleshooting, and unit specifications. Includes model details for various series.
PreviewMidea Window Air Conditioner Owner's Manual
Comprehensive owner's manual for Midea window air conditioners, including models WWMW050CM1A and MWMWT060CR1A. Provides safety precautions, operating instructions, installation guidelines, care and cleaning tips, troubleshooting, and warranty information.
PreviewMidea MWMWT080CR1A Window Air Conditioner Owner's Manual
Comprehensive owner's manual for the Midea MWMWT080CR1A Window Air Conditioner, covering installation, operation, safety, maintenance, troubleshooting, and warranty information.
PreviewMidea Mobile Air Conditioner Owner's Manual & Installation Guide - CP002UI-PT
User and installation manual for Midea mobile air conditioners, model CP002UI-PT. Covers safety, setup, operation, maintenance, and troubleshooting.