Water heater in heat pump

NEW

Internal External
E

O-FRIEND C

LY

F

IGERANT R

G

Code 2CP0022L 2CP0023L Code
2CP00280

Model DORA TECH 200 HT DORA TECH 260 HT Accessories
Cascade regulator kit (1 piece should be installed for each water heater in cascade)

Control panel

The simple and intuitive programmable control system on board the machine allows selection of the various Operating Modes: Eco: heat pump only (Max setpoint 62°C) / Auto: heat pump with heating element for possible support (Max setpoint 62°C) / Boost: heat pump and heating element at the same time (Max setpoint 75°C) / Electric: heating element only (Max setpoint 75°C) / Fan: active ventilation only.

The DORA TECH electronics are able to optimize the integration of energy from other sources, exploiting the possible availability of photovoltaic electricity. The DORA TECH electronics can manage and optimize the integration of energy from other sources: activating and exploiting any overproduction of photovoltaic electricity by raising the temperature of water in the storage tank up to a value set by the user (max 75°C).

Application
The air can be ducted in order to direct the flow appropriately in different situations.

Air temperature > -7°C

Dora Tech HT
Heat pump water heater for floor-standing installation with positive air temperatures - Air heat pump and integrated storage tank for DHW production with inlet air
temperature range not lower than 4°C - Possibility of ducting the expelled air - Floor-standing installation - Available operating modes: Eco, Auto, Boost, Electric, Fan - Wi-Fi card installed as standard and control via smartphone using the
"LAMBORGHINI CALORECLIMA HOME" App - 1500 W support heating element - Simple and intuitive touch control panel on board machine - Enameled steel water storage tank with 50 mm polyurethane insulation - Aluminum main heat exchanger outside the tank - Corrosion protection by means of magnesium anode - Programmable anti-legionella cycle - Arrangement (digital input) for activation with availability of
photovoltaic energy - Arrangement (digital input) for activation with reduced electricity rates - R134a ecological gas
Connectivity
CONNECTIVITY Thanks to the "LAMBORGHINI CALORECLIMA HOME" App downloadable on smartphone, DORA TECH can be fully managed by changing its parameters and operating modes.
Lamborghini CaloreClima Home
Limits of use
TEMPERATURE RANGE. The graph below indicates the temperature range of the produced air and water, which guarantees correct operation.
A Inlet air temperature °C B Temperature of hot
water produced °C Working range for heat pump Integration with heating element only

Use of energy present in the environment (BOILER ROOM OR LAUNDRY)

POWER SUPPLY VOLTAGE RANGE. The table below provides the admissible variation conditions for the electrical power supply

Standard power supply Admissible voltage range

V-ph-Hz V

230-1-50 207 - 254

110

Water heater in heat pump

DORA TECH Nominal storage capacity Max. hot water capacity at 40°C Storage dispersion DHW max. temperature with heat pump only DHW max. temperature with supplementary electric booster Integrated heating element power Average absorbed power in heating Pump heat output Dimensions (Ø x H) Empty weight Max. water pressure Max. air temperature Min. air temperature Nominal air flow Max. available head for cold air outlet Duct diameter Required room volume Power supply parameters Protection rating Indoor sound power Lw(A) Gas type Charge quantity Heating time 7°C in ECO mode COP Internal coil for solar
Energy efficiency class for heating water in average climatic conditions
Energy efficiency of water heating in % in average climatic conditions Annual energy consumption in average climatic conditions Declared load profile

L L W °C °C W W W mm kg bar °C °C m3/h Pa mm m3 V-Hz
dB(A)
g hh:mm
% kW/h

200 HT 192 260 60 62 75 1500 370 1248
621 x 1607 86 7 43 4 350 100 160 >20
230V - 50Hz IP24 52 R134a 1000 07:16 2,8 --
A+
116 883 L

* Test in accordance with EN16147-2017 with air inlet temperature at 20°C, boiler storage ambient temperature 20°C, water heating from 10°C to 55°C.

Dimensions and hydraulic connections (in mm)

260 HT 250 358 70 62 75 1500 370 1283
621 x 1892 98 7 43 4 350 100 160 >20
230V - 50Hz IP24 52 R134a 1000 09:44 3,1 --
A+
127 1315 XL

DORA TECH

A

mm

B

mm

D

mm

E

mm

G

mm

H

mm

M mm

N

mm

O* mm

P

mm

Ø 1"G 1"G 3/4"G 3/4"G 1/2"G -

200 HT 250 490 705 876,5 1142 1607 705 877 976 1073

260 HT 250 493 785 1162 1427 1892 735 1162 1261 1358

* Outlet connection in plastic material