Altronix RBSNP Polarized Relay Module Instruction Manual
File info: application/pdf · 1 pages · 444.29KB
IIRBSNP F21U
Click to View
Altronix RBSNP | Relay Module, 12VDC, DPDT Contacts @ 2A/120
RBSNP Installation Guide
RBSNP-Installation-Guide
Altronix RBSNP Relay Module, 12VDC, DPDT Contacts @ 2A/120VAC or 2A/28VDC, Polarized | 123 Security Products
Extracted Text
RBSNP Polarized Relay Module Installation Guide Input Voltage: � 12VDC operation. � Current draw: 15mA. � Polarity sensitive input. Contact Rating: � 2A/120VAC or 2A/28VDC Double form "C" DPDT contacts. Specifications: Mechanical: � Snap track mountable (order part # ST1). � Board dimensions (L x W x H approx.): 2.75" x 1.625" x 0.875" (69.9mm x 41.3mm x 22.2mm) Dry Contacts Polarity Reversal PHONE LINE POWER IN NO NC C NEG -- NO NC C POS + NO NC C NEG -NO NC C POS + --- --- + TO BELL OUTPUT TERMINALS OF CONTROL PANEL Latching Dry Contacts N.C. RESET SWITCH + TO BELL OUTPUT TERMINALS OF CONTROL PANEL TO PHONE LINE Line Seizure USED TO MAKE/ BREAK LOAD NO NC C POS + NO NC C NEG -NO NC C POS + N.O. TRIP SWITCH + CONSTANT POWER SOURCE + TO BELL OUTPUT TERMINALS OF CONTROL PANEL NO NC C NEG -- TO ALARM TRANSMITTER HOUSE PHONE IN COMING TELEPHONE LINE Altronix is not responsible for any typographical errors. ���������������������������������������������������������������������������������������������������������������� 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIRBSNP - Rev. 061501 F15U MEMBER